Tender For Repair And Maintenance Infrastructure Assets In Ndmc. Sh. Electrical And Mechanical Repair Work At Tugluck Crescent Water Boosting Station, New Delhi-Delhi

New Delhi Municipal Council-NDMC has published Tender For Repair And Maintenance Infrastructure Assets In Ndmc. Sh. Electrical And Mechanical Repair Work At Tugluck Crescent Water Boosting Station. Submission Date for this Tender is 17-08-2023. Infrastructure Work Tenders in New Delhi Delhi. Bidders can get complete Tender details and download the document.




Tender Notice

39054027
Tender For Repair And Maintenance Infrastructure Assets In Ndmc. Sh. Electrical And Mechanical Repair Work At Tugluck Crescent Water Boosting Station
Open Tender
Indian
Delhi
New Delhi
17-08-2023

Tender Details

Repair And Maintenance Infrastructure Assets In Ndmc. Sh. Electrical And Mechanical Repair Work At Tugluck Crescent Water Boosting Station

Key Value

Document Fees
Refer document
EMD
INR 18842.0 /-
Tender Value
INR 9.42 Lakhs /-

BOQ Items

Name of Work: Repair and Maintenance – Infrastructure Assets in NDMC. SH: Electrical and Mechanical repair work at Tugluck Crescent Water Boosting Station.
Sl. No. Item Description
1Providing & replacingSchneider / L & T ( DN2-250M) CM9217100POOG make 250amps. Triple pole Moulded Case Circuit Breaker(MCCBs for Motor back-up Protection) suitablefor fixing at the main panel board incomer , including cost of labour charges for dismantling of existing & Providing/installation of new mccb and including providing & fixing copper thimbles , bus bar / cable , Aluminium links , strips ( as required at site),spreader terminals testing and commissioning etc. Complete as per direction and satisfaction of engineer-in-charge
2Providing and fixing B C H/ L& T makeAir Break Push Button operated fully automatic citation star-delta starter (Cat. No. NASACT3LEEM ) comprising of three Nos. M contactors (70 Amps), one No. over load relay (Relay range: 56.4- 90.0Amps), and one No. pneumatic timer suitable for operation on 400/ 440 volt, 3 phase, 50 Hz A C supply in sheet steel enclosureincludingproviding and fixing required copper thimbles, making electrical and earth connections, also Providing and fixing M.S. angle iron frame ofangle size 75 X 75 X 6 mmfor mounting the starter on provided M.S frame including testing and commissioning etc. complete as per the satisfactionof engineer in charge
3Providing and replacing the existing no-good pressure gauge by providing new150 mm diameter Fiebig /Guru make pressure gauge (bottom connected, surface mounting) of 0 to 7kg/cm squareincluding providing & welding 15 mm G.I. socket to the new pressure gauge by providing & fixing 1 meters long, 15 mm dia. G.I. pipe (class B) including fittings, cutting , welding, threading etc. as per the site requirement & testing etc. complete as per direction and satisfaction of engineer-in-charge.
4Providing and replacing the existing no-good vacuum gauge by providing new 150/140 mm diameter Fiebig /Guru make vacuum gauge (bottom connected, surface mounting) of 0 to (-)760 mmHg rangeincluding providing, welding (if required) and fixing the inlet of gauge with 15 mm dia G.I.socketto the new pressure gauge by providing & fixing 1 meters long, 15 mm dia. G.I. pipe (class B)including all fittings, cutting , welding, threading etc. as per the site requirement & testing etc. complete as per direction and satisfaction of Engineer-in-charge.
5Providing and replacingAE make (144*144) square mm dia dial (0 -100) Amps range Ampere meters with C.T operated ( including providing of 100/5 Amp, C T ) and suitable for operation on 440 Volts AC supply. including dismantling existing meter and fixing new one,thimble,cartage,pvc tapes etc.)Complete as per direction and satisfaction of engineer in charge
6Providing and replacingAE make (144*144) square mm dia dial (0 -30) Amps range Ampere meters with C.T operated ( including providing of 30/5 Amp, C T ) and suitable for operation on 440 Volts AC supply. including dismantling existing meter and fixing new one, thimble, cartage, pvc tapes etc.)Complete as per direction and satisfaction of engineer in charge
7Providing and replacing AE make (144*144) square mm dia dial (0-500) Volt meter and suitable for 400/440 volts AC supply (including dismantling existing meter and fixing new one, thimble, cartage, pvc tapes etc.)Complete as per direction and satisfaction of engineer in charge
8Providing and fixing of L & T (Cat.No. CO51000OSOO)/ Siemens make Onload manual changeover switchin sheet steel enclosure of 1000amp415V fitted in MS angle frame of( angle size 75 x75x 6mm thick) fixed at floor with iron metal fasteners (12mm and 150mm long) &Bakelite sheet of6 mm thick of required size at frame as directed by engineer in charge,includingmaking connection with the main supply including thimbles of required sizeat both endsetc complete in all respectas per direction and satisfaction of engineer in charge.
9Supplying and fixing Finolex/National/kalinga Gold make95mm² P.V.C Insulated unsheathed Three core Almuniumconductor armoredcable suitable for voltage grade up to 1100V complete with thimbles connectors Insulating tapes, gland of required size etc. as required for making connection from Panel board to starter. Complete as per direction and satisfaction of engineer-in-charge
10Supplying and fixing Finolex/National/kalinga Gold make50 mm² P.V.C Insulated unsheathed single core copper conductor flexible cable suitable for voltage grade up to 1100V complete with thimbles connectors Insulating tapes, gland of required size etc. as required for making connection from starter to motor. Complete as per direction and satisfaction of engineer-in-charge.
11Providing and replacing the existing gate valve by providing new 40 mmSant Forged Brass ball valve two piece design PN-25 lever operated brass (Nickle plated ) forged brassNickle plated Screwed female BSP parallel thread renewable P.T.F.E,of approved quality as per direction and satisfaction of Engineer-in-charge.
12Providing and fixing burnt out connection plate for motors with thimbles, insulation tape, nut bolt etc. Complete as per direction and satisfaction of engineer-in-charge., ( A)60HP
13Dismembering of pump set(induction motor and centrifugal pump) from exiting base frame and fixing it again on new base frame. Including disconnection and connection of cables of pump set from starter, making proper alignment of induction motor and centrifugal pump after fixing at new base frame for smooth functioning, labour charges, cartage, loading, unloading etc complete as per direction and satisfaction of engineer in charge
14Demolishing cement concrete manually/ by mechanical means including disposal of material within 50 meters lead as per direction of Engineer - in - charge. Nominal concrete 1:3:6 or richer mix (i/c equivalent designmix)
15Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level :1:2:4 (1 Cement : 2 coarse sand (zone-III)derived from natural sources : 4 graded stone aggregate 20 mm nominal size derived from natural sources )
16Centering and shuttering including strutting, propping etc. and removal of form for : Foundations, footings, bases of columns, etc. for mass concrete
17Printing and supplying of Log Book for Water Boosting Station of size 21.5 cm *34 cm having 100 sheets duly numbered as per sample with binding I / c printing N D M C logo on the top of binding and on the first page , stacking the same at Jor Bagh S / C (as per approved paper and pattern by Engineer – in- charge .
Disclaimer :
We takes all possible care for accurate & authentic tender information, however Users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender.
Tell us about your Product / Services,
We will Find Tenders for you

Copyright © 2024 · All Rights Reserved. Terms of Usage | Privacy Policy

For Tender Information Services Visit : TenderDetail