415V Mv Switchgear -Drawout Type 415V Mv Switchgear ( Drawout Type-Mldb, Emldb, Asb, Pdb ) For Numaligarh Refinery Expansion Project , Mv Switchboard ( Drawout Type ) , 415V, 400 A, 20Ka ( 1 Sec ) Nrep Main Substation ( Ss#10 ) : Mv Switchboard – Mldb ( 415V Ac, 3Ph, 4W, 50Hz, 400A, 20Ka For 1 Sec ) , Drawout Type As Per Sld, Feeder List & Tender Documents Attached With Mr , Mv Switchboard ( Drawout Type ) , 415V, 250 A, 20Ka ( 1 Sec ) Nrep Main Substation ( Ss#10 ) : Mv Switchboard – Emldb ( 415V Ac, 3Ph, 4W, 50Hz, 250A, 20Ka For 1 Sec ) , Drawout Type As Per Sld, Feeder List & Tender Documents Attached With Mr. , Mv Switchboard ( Drawout Type ) , 415V, 800 A, 50Ka ( 1 Sec ) Nrep Main Substation ( Ss#10 ) : Mv Switchboard – Asb ( 415V Ac, 3Ph, 4W, 50Hz, 800 A, 50Ka For 1 Sec ) , Drawouttype As Per Sld, Feeder List & Tender Documents Attached With Mr. , Power Distribution Panel ( Wall Mounted Type ) , 415V, 3Ph, 315 A, 10Ka ( 1 Sec ) For Nrep Main Substation ( Ss#10 ) As Per Sld, Feeder List & Tender Documents Attached With Mr. , Power Distribution Panel ( Wall Mounted Type ) , 415V, 3Ph, 200 A, 10Ka ( 1 Sec ) For Nrep Main Substation ( Ss#10 ) As Per Sld, Feeder List & Tender Documents Attached With Mr. , Mv Switchboard ( Drawout Type ) , 415V, 400 A, 20Ka ( 1 Sec ) Utility Substation ( Ss#13 ) : Mv Switchboard – Mldb ( 415V Ac, 3Ph, 4W, 50Hz, 400A, 20Ka For 1 Sec ) , Drawout Type As Per Sld, Feeder List & Tender Documents Attached With Mr. , Mv Switchboard ( Drawout Type ) , 415V, 250 A, 20Ka ( 1 Sec ) Utility Substation ( Ss#13 ) : Mv Switchboard – Emldb ( 415V Ac, 3Ph, 4W, 50Hz, 250A, 20Ka For 1 Sec ) , Drawout Type As Per Sld, Feeder List & Tender Documents Attached With Mr. , Mv Switchboard ( Drawout Type ) , 415V, 800 A, 50Ka ( 1 Sec ) Utility Substation ( Ss#13 ) : Mv Switchboard – Asb ( 415V Ac, 3Ph, 4W, 50Hz, 800A, 50Ka For 1 Sec ) , Drawout Type As Per Sld, Feeder List & Tender Documents Attached With Mr. , Power Distribution Panel ( Wall Mounted Type ) , 415V, 3Ph, 200 A, 10Ka ( 1 Sec ) For Utility Substation ( Ss#13 ) As Per Sld, Feeder List & Tender Documents Attached With Mr. , Power Distribution Panel ( Wall Mounted Type ) , 415V, 3Ph, 400 A, 10Ka ( 1 Sec ) For Utility Substation ( Ss#13 ) As Per Sld, Feeder List & Tender Documents Attached With Mr. , Power Distribution Panel ( Wall Mounted Type ) , 415V, 3Ph, 315 A, 10Ka ( 1 Sec ) For Utility Substation ( Ss#13 ) As Per Sld, Feeder List & Tender Documents Attached With Mr. , Mv Switchboard ( Drawout Type ) , 415V, 630 A, 20Ka ( 1 Sec ) Etp & Cooling Tower Substation ( Ss#14 ) : Mv Switchboard – Mldb ( 415V Ac, 3Ph, 4W, 50Hz, 630A, 20Ka For 1 Sec ) , Drawout Type As Per Sld, Feeder List & Tender Documents Attached With Mr. , Mv Switchboard ( Drawout Type ) , 415V, 315 A, 20Ka ( 1 Sec ) Etp & Cooling Tower Substation ( Ss#14 ) : Mv Switchboard – Emldb ( 415V Ac, 3Ph, 4W, 50Hz, 315A, 20Ka For 1 Sec, Drawout Type As Per Sld, Feeder List & Tender Documents Attached With Mr. , Mv Switchboard ( Drawout Type ) , 415V, 800 A, 50Ka ( 1 Sec ) Etp & Cooling Tower Substation. ( Ss#14 ) : Mv Switchboard – Asb ( 415V Ac, 3Ph, 4W, 50Hz, 800 A, 50Ka For 1 Sec, Drawout Type As Per Sld, Feeder List & Tender Documents Attached With Mr , Mv Switchboard ( Drawout Type ) , 415V, 630 A, 20Ka ( 1 Sec ) Offsites-I Substation ( Ss#17 ) : Mv Switchboard – Mldb ( 415V Ac, 3Ph, 4W, 50Hz, 630A, 20Ka For 1 Sec ) , Drawout Type As Per Sld, Feeder List &Tender Documents Attached With Mr , Mv Switchboard ( Drawout Type ) , 415V, 250 A, 20Ka ( 1 Sec ) Offsites-I Substation ( Ss#17 ) : Mv Switchboard – Emldb ( 415V Ac, 3Ph, 4W, 50Hz, 250A, 20Ka For 1 Sec ) , Drawout Type As Per Sld, Feeder List & Tender Documents Attached With Mr. , Mv Switchboard ( Drawout Type ) , 415V, 630 A, 50Ka ( 1 Sec ) Offsites-I Substation ( Ss#17 ) : Mv Switchboard – Asb ( 415V Ac, 3Ph, 4W, 50Hz, 630 A, 50Ka For 1 Sec, Drawout Type As Per Sld, Feeder List & Tender Documents Attached With Mr. , Power Distribution Panel ( Wall Mounted Type ) , 415V, 3Ph, 160 A, 10Ka ( 1 Sec ) For Offsites-I Substation ( Ss#17 ) As Per Sld, Feeder List & Tender Documents Attached With Mr. , Power Distribution Panel ( Wall Mounted Type ) , 415V, 3Ph, 315 A, 10Ka ( 1 Sec ) For Offsites-I Substation ( Ss#17 ) As Per Sld, Feeder List & Tender Documents Attached With Mr. , Mv Switchboard ( Drawout Type ) , 415V, 400 A, 20Ka ( 1 Sec ) Offsites-Ii Substation ( Ss#18 ) : Mv Switchboard – Mldb ( 415V Ac, 3Ph, 4W, 50Hz, 400A, 20Ka For 1 Sec ) , Drawout Type As Per Sld, Feeder List & Tender Documents Attached With Mr. , Mv Switchboard ( Drawout Type ) , 415V, 80 A, 20Ka ( 1 Sec ) Offsites-Ii Substation ( Ss#18 ) : Mv Switchboard – Emldb ( 415V Ac, 3Ph, 4W, 50Hz, 80A, 20Ka For 1 Sec ) , Drawout Type As Per Sld, Feeder List & Tender Documents Attached With Mr. , Mv Switchboard ( Drawout Type ) , 415V, 630 A, 50Ka ( 1 Sec ) Offsites-Ii Substation ( Ss#18 ) : Mv Switchboard – Asb ( 415V Ac, 3Ph, 4W, 50Hz, 630 A, 50Ka For 1 Sec ) , Drawouttype As Per Sld, Feeder List & Tender Documents Attached With Mr. , Power Distribution Panel ( Wall Mounted Type ) , 415V, 3Ph, 250 A, 10Ka ( 1 Sec ) For Offsites-Ii Substation ( Ss#18 ) As Per Sld, Feeder List & Tender Documents Attached With Mr. , Mv Switchboard ( Drawout Type ) , 415V, 200 A, 20Ka ( 1 Sec ) Mcr-2 ( Dcu ) : Mv Switchboard – Eldb ( 415V Ac, 3Ph, 4W, 50Hz, 200A, 20Ka For 1 Sec ) , Drawout Type As Per Sld, Feeder List & Tender Documents Attached With Mr , Power Distribution Panel ( Floor Mounted Type ) , 415V, 3Ph, 800 A, 10Ka ( 1 Sec ) For Mcr-2 ( Dcu ) As Per Sld, Feeder List & Tender Documents Attached With Mr. , Power Distribution Panel ( Wall Mounted Type ) , 415V, 3Ph, 160 A, 10Ka ( 1 Sec ) For Mcr-2 ( Dcu ) As Per Sld, Feeder List & Tender Documents Attached With Mr. , Mv Switchboard ( Drawout Type ) , 415V, 63 A, 10Ka ( 1 Sec ) Raw Water Intake Substation ( Ss#30 ) : Mv Switchboard – Mldb ( 415V Ac, 3Ph, 4W, 50Hz, 63A, 10Ka For 1 Sec ) , Drawout Type As Per Sld, Feeder List & Tender Documents Attached With Mr , Mv Switchboard ( Drawout Type ) , 415V, 400 A, 10Ka ( 1 Sec ) 220Kv / 33Kv Gis Switchyard ( Ss#21 ) : Mv Switchboard – Mldb ( 415V Ac, 3Ph, 4W, 50Hz, 400A, 10Ka For 1 Sec ) , Drawout Type As Per Sld, Feeder List & Tender Documents Attached With Mr. , Mv Switchboard ( Drawout Type ) , 415V, 630 A, 50Ka ( 1 Sec ) 220Kv / 33Kv Gis Switchyard ( Ss#21 ) : Mv Switchboard – Asb ( 415V Ac, 3Ph, 4W, 50Hz, 630 A, 50Ka For 1 Sec ) , Type As Per Sld, Feeder List & Tender Documents Attached With Mr. , Special Tools And Tackles For The Entire Package For Erection, Installation, Testing, Commissioning, Operation & Maintenance As Per Oem Recommendations As Per Manufacturer’S Recommendation , Pre-Commissioning / Commissioning / Start-Up Spare Parts For Entire Mv Switchboards - 415V As Per Manufacturer’S Recommendation , Training To 2 Nos. Of Owner Personnel At Oem’S Factory For 1 Week For The Entire Package , Training To 10 Nos. Of Owner Personnel At Nrep Site For 1 Week For The Entire Package , Bidder Shall Provide Per Diem Rate For Supervision Services For Installation Of The Entire Package And For Commissioning / Support Engineer From Oem Shall Be Stationed At Nrep Site For The Duration Of 1 Month From The Date Of Commissioning & Handover For The Entire Package , Additional Cost If Any For The Additional Warranty Period Of “24Months After Commissioning Or 36Months After Dispatch Whichever Is Earlier” Over And Above The Standard Warranty Period.Refer Note-11