Sales : +91-777 804 8217
| Sr No | Corrigendum Date | Corrigendum | Type | New Submission Date |
|---|---|---|---|---|
| 1 | 05-09-2023 | Bid Auto Extn Corrigendum | Bid Auto Extn Corrigendum | 11-09-2023 |
| 2 | 29-08-2023 | Bid Auto Extn Corrigendum | Bid Auto Extn Corrigendum | 05-09-2023 |
| 3 | 21-08-2023 | BOQ | BOQ | 29-08-2023 |
| Sl. No. | Item Description |
| 1 | M & L for routine check up and servicing of soft starter of model EMX4iof capacity 24 to 200 Amp,duly recommending the maintanance/replacement of the UNSV parts required which are not working properly. All parts shall be measured and paid seperately here-in-after. Maintanance/servicing shall be carried out by OEM maint engineer only & proper setting of O/L, running, starting / stopping, ramping time with proper measurememnt of each & every set of starter. Mainly HMI module, PCB, CT, Fan, Thyristor and by pass. Complete all as directed by Engr-in-Charge at site. |
| 2 | Supply and fix in replacement Kit User Iinterface CI M/R 0020-0129make L & T model EMX4ifor capacity 24Amp to 135Amp , Cat No 995-18604-00 |
| 3 | All as per Ser item No 2 above but for capacity 184 Amp to 200 Amp , Cat No 995-18605-00 |
| 4 | Supply and fix in replacement of Kit Motor Ctrl V5 M/R 0020-0129 make L & T model EMX4iof capacity 24Amp to 135Amp, Cat No 995-18607-00 |
| 5 | Supply and fix in replacement of Kit Motor Ctrl V5 M/R 0143--0580 make L & T model EMX4i of capacity 184Amp to 200 Amp ,Cat No 995-18608-00 |
| 6 | Supply and fix in replacement of Kit SCR M/R 0020 make L & T model EMX4iof capacity 24Amp , Cat No 995-18612-00 |
| 7 | Supply and fix in replacement of Kit SCR M/R 0034-0041 make L & T model EMX4iof capacity42Amp to 52 Amp, Cat No 995-18613-00 |
| 8 | Supply and fix in replacement of Kit SCR M/R 0085-0107 make L & T model EMX4iof capacity105Amp to 115 Amp, Cat No 995-18615-00 |
| 9 | Supply and fix in replacement of Kit SCR M/R 0129 make L & T model EMX4iof capacity135 Amp ,Cat No 995-18616-00 |
| 10 | Supply and fix in replacement of Kit SCR M/R 0143-0193 make L & T model EMX4iof capacity 184 Amp to 200 Amp, Cat No 995-18617-00 |
| 11 | Supply and fix in replacement of Kit Fan M/R 0041-0129 make L & T model EMX4iof capacity 24Amp to 135Amp,Cat No 995-18622-00 |
| 12 | Supply and fix in replacement of Kit Fan M/R 0043-0580 make L & T model EMX4iof capacity ofcapacity 184Amp to 200Amp,Cat No 995-18623-00 |
| 13 | Supply and fix in replacement of Kit CT M/R 0020-0129 make L & T model EMX4iof capacity 24Amp to 135Amp,Cat No 995-18624-00 |
| 14 | Supply and fix in replacement of Kit CT M/R 0143-0243 make L & T model EMX4iof capacity 184Amp to 200Amp,Cat No 995-18625-00 |
| 15 | Supply and fix in replacement of Bypass Contactor Kit, M/R 0020-0069 make L & T model EMX4iofcapacity 24Amp to 69Amp,Cat No 995-18628-00 |
| 16 | Supply and fix in replacement of Bypass Contactor Kit, M/R 0085-0129 make L & T model EMX4iof capacity 105Amp to 135Amp,Cat No 995-18629-00 |
| 17 | Supply and fix in replacement of Bypass Contactor Kit, M/R 0143-0243 make L & T model EMX4iof capacity 184Amp to 200Amp,Cat No 995-18630-00 |
| 18 | Supply and fix in replacement of Kit snubber M/R 0020-0069 make L & T model EMX4iof capacity 24Amp to 69Amp,Cat No 995-18633-00 |
| 19 | Supply and fix in replacement of Kit snubber M/R 0085-0129 make L & T model EMX4iof capacity 105Amp to 135Amp,Cat No 995-18634-00 |
| 20 | Supply and fix in replacement of Kit snubber M/R 0143-0243 make L & T model EMX4iof capacity 184Amp to 200Amp,Cat No 995-18635-00 |
| 21 | M & L for routine check up and servicing of soft starter of model CSXi of capacity 7.5KW to 110KW,duly recommending the maintanance/replacement ofthe UNSV parts required which are not working properly. All parts shall be measured and paid seperately here-in-after. Maintanance/servicing shall be carried out by OEM maint engineer only & proper setting of O/L, running, starting / stopping, ramping time with proper measurememnt of each & every set of starter. MainlyPCB, CT, Fan, Thyristor and by pass. Complete all as directed by Engr-in-Charge at site. |
| 22 | Supply and fix in replacement CSXi, Kit,Mn Ctrl PCB,1,V4,C1,007-110make L & T model CSXi of capacity 7.5 to 110 KW , Cat No 995-02537-00 |
| 23 | Supply and fix in replacement CSXi, Kit,,Interface PCB,022make L & T model CSXi of capacity 22 KW , Cat No 995-02549-00 |
| 24 | Supply and fix in replacement CSXi, Kit,,Interface PCB,037make L & T model CSXi of capacity 37 KW , Cat No 995-04517-00 |
| 25 | Supply and fix in replacement CSXi, Kit,,Interface PCB,055make L & T model CSXi of capacity 55 KW , Cat No 995-04519-00 |
| 26 | Supply and fix in replacement CSXi, Kit,,Interface PCB,110make L & T model CSXi of capacity 110 KW , Cat No 995-03877-00 |
| 27 | Supply and fix in replacement CSXi, Kit,,By pass Relay, 007-030make L & T model CSXi of capacity 7.5 KW to 30KW , Cat No 995-02568-00 |
| 28 | Supply and fix in replacement CSXi, Kit,,By pass Relay, 037-055make L & T model CSXi of capacity 37 KW to 55KW , Cat No 995-04515-00 |
| 29 | Supply and fix in replacement CSXi, Kit,,By pass Relay, 075-110make L & T model CSXi of capacity 75 KW to 110KW , Cat No 995-03873-00 |
| 30 | Supply and fix in replacement CSXi, Kit,Current transformer 037-055 make L & T model CSXi of capacity 37 KW to 55KW , Cat No 995-02572-00 |
| 31 | Supply and fix in replacement CSXi, Kit,SCR 037 make L & T model CSXi of capacity 37 KW, Cat No 995-02562-00 |
| 32 | Supply and fix in replacement CSXi, Kit,SCR 055 make L & T model CSXi of capacity 55 KW, Cat No 995-02564-00 |
| 33 | Supply and fix power contactor 3 pole of capacity 300 Amp rating 415 Volt / AC-3 duty recommended to suit existing type, make & modelto suit existing mounting space. |
| 34 | All as per item No. 32 but for capacity 250 to 265 Amp |
| 35 | All as per item No. 32 but of capacity 185 to 200 Amp |
| 36 | All as per item No. 32 but of capacity 140 to 150 Amp |
| 37 | All as per item No. 32 but of capacity 225 Amp |
| 38 | All as per item No 32 but of capacity 95 to 110 Amp |
| 39 | All as per item No. 32 but of capacity 63 to 70Amp |
| 40 | All as per item No. 32but of capacity 40 to 50 Amp |
| 41 | Supply and fix in repair start / stop push botton as per existing for motor control panel |
| 42 | S& F in replacement of Pneumatic Timers Time Delay Relay-Electro Pneumatic type along with suitable Nos of NO+NC as per control panel of starter as existing for time delay 0 to 60 secondsetting on stepssuitabile for 100 to 150 HP motor starting panel. cat no KRTPCN11M- 1 |
| 43 | S& F in replacementoverload relay of Range 10 to 30 Amp rating to suit safe operation of induction/ submersible motor of capacity up to 15HP motor.Make BCH or equivalent |
| 44 | All as per item No. 42 here-in-above but CT operated relay range 188 to 300A for 150/100HP motorstarter of auto transformer type for ATS panel make BCH HSN Code 8536 cat code CT6MC305ANA3C or equivalent |
| 45 | M&L for rewinding of autotransformer unit of A/T starter complete with winding wire of super enamelled Impregnated copper wire of existing size and type complete with empire tape, glass tape, impregnated paper, bambooChips etc & transporting from panel place to wksp and back, reconnection after completion and testing of load, for 150 HP PUMP ,all as directed by Engr-in-Charge. |
| 46 | M&L for electrical disconnetion of submersible pump for taking out existing column pipe of size 32 to 80 mm along with pump set 1to 10 HP from borewell with essential toolslike tripod, chain, pully, etc and manpower& replacement of unserviceable parts of column pipe,motor, pump etc as per requirement, spare parts and column pipe shall be measured and paid seperately, lowering of submersible pumping set with column pipe complete and testing after completion of work all as directed by Einr-in-Charge. Note: i) Repair of pump and motor will be paid and measured seperately under respective items. ii)Minor items such as rubber packing, gaskets, grease etc deemed to be included. |
| 47 | M&L for repair /servicing of submersible pump set, strip opening multi stage submersible pumpset of capacity 1 to 1.5HP. Replacement of unsv parts & reassembling the same, testing after completion of of job & spare parts shall be measured & paid seperately here-in-after. Complete all as directed by Engr-in-Charge. |
| 48 | Supply onlyImpelleras required for Item Ser No 46. |
| 49 | Supply only Sleeve coupling as required for Item Ser No 46. |
| 50 | Supply only allen key screw as required for Item Ser No 46. |
| 51 | Supply only thrust bearing set as required for Item Ser No 46. |
| 52 | Supply only Bush as required for Item Ser No 46. |
| 53 | Material and labour for rewinding of submersible electric motors transporting from site to repair shop and repair shop to site, dismantling, stripping out and removing old burnt winding wire, cleaning of slots etc. Rewinding complete with super enamelled copper winding wire of appropriate gauge including all necessary insulation material class-I, varnishing and heating as per requirment. Re-installing in position, assembling at site, realigning with pump set, coupling with pump,making electric connectionall as direcred and testing for smooth functioningfor following capacity (a)1/1.5 HP Single phase. |
| 54 | M&L for repair of submersible pump set, strip opening multi stage submersible pumpset of capacity 5 to 10HP. Replacement of unsv parts & reassembling the same, testing after completion of job & spare parts shall be measured & paid seperately here-in-after. Complete all as directed by Engr-in-Charge. |
| 55 | Supply only Thrust bearing as required for Item Ser No 48. |
| 56 | Supply only Bowl set as required for Item Ser No 48. |
| 57 | Supply onlyimpellor driving rod (shaft) completeas required for Item Ser No 48. |
| 58 | Supply only Impellor set as required for Item Ser No 48. |
| 59 | Supply onlyBushas required for Item Ser No 48. |
| 60 | Supply only MS Coupling as required for Item Ser No 48. |
| 61 | Material and labour for rewinding of submersible electric motors transporting from site to repair shop and repair shop to site, dismantling, stripping out and removing old burnt winding wire, cleaning of slots etc. Rewinding complete with PVC submersiblecopper winding wire of appropriate gauge including all necessary insulation materialas per requirment. Re-installing in position, assembling at site, realigning with pump set, coupling with pump,making electric connectionall as direcred and testing for smooth functioningforcapacity 5 HP three phase.(Make of winding wire) |
| 62 | Material and labour for rewinding of submersible electric motors transporting from site to repair shop and repair shop to site, dismantling, stripping out and removing old burnt winding wire, cleaning of slots etc. Rewinding complete with PVC submersiblecopper winding wire of appropriate gauge including all necessary insulation materialas per requirment. Re-installing in position, assembling at site, realigning with pump set, coupling with pump,making electric connectionall as direcred and testing for smooth functioningforcapacity 7.5 HP three phase.(Make of winding wire) |
| 63 | Material and labour for rewinding of submersible electric motors transporting from site to repair shop and repair shop to site, dismantling, stripping out and removing old burnt winding wire, cleaning of slots etc. Rewinding complete with PVC submersiblecopper winding wire of appropriate gauge including all necessary insulation materialas per requirment. Re-installing in position, assembling at site, realigning with pump set, coupling with pump,making electric connectionall as direcred and testing for smooth functioningforcapacity 10 HP three phase. (Make of winding wire) |
| 64 | S&F in repair Single phase preventor type D2, VMR1 |
| 65 | Supply and fix high pressure cooling pipe with end connections suitable for 50/60/75/100/150HP kirloskar pump pump. |
| 66 | Supply and fix in repair rubber coupling Star type suitable for following size Pump complete all as specified and directed.(a)150 HP |
| 67 | All as per item Ser No 54 above but for5 75/100HP |
| 68 | All as per item Ser No 54 above but for50 /60HP |
| 69 | All as per item Ser No 54 above but for10/12.5/15HP |
| 70 | Supply and fix in repair rubber coupling tyre type suitable for15 HP of centrifugal Pumping set complete all as specified and directed |
| 71 | All as per Item Ser No 55 above but for 75/100HP |
| 72 | All as per Item Ser No 55 above but for 20/25 HP |
| 73 | M&L for routine / Preventive maint of pump / motor set complete of size150 HP. SKF high performance, high temperature superior quality pump & motor bearing grease of model - SKF LG HP 2/18 or equivalant quality of make castrol / Valvoline etc, nut / bolts, complete with repair / replacment of unsv acessories like cooling pipe/ drain pipe, washer,packing etc complet. All items likehose set nipple, washer, ball valve Gland having high purity with lubricant, alinment of pump and motor etc shall be deemed to be included in repair.Record shall be maintained in register duly singed by Engr-in-Charge. |
| 74 | M&L for routine / Preventive maint of pump / motor set complete of size 100 HP. SKF high performance, high temperature superior quality pump & motor bearing grease of model - SKF LG HP 2/18 or equivalant quality of make castrol / Valvoline etc, nut / bolts, complete with repair / replacment of unsv acessories like cooling pipe/ drain pipe, washer,packing etc complet. All items likehose set nipple, washer, ball valve Gland having high purity with lubricant, alinment of pump and motor etc shall be deemed to be included in repair.Record shall be maintained in register duly singed by Engr-in-Charge. |
| 75 | M&L for routine/Preventive maint of pump / motor set complete of size 75 to 50 HP. SKF high performance, high temperature superior quality pump & motor bearing grease of model - SKF LG HP 2/18 or equivalant quality of make castrol / Valvoline etc, nut / bolts, complete with repair / replacment of unsv acessories like cooling pipe/ drain pipe, washer,etc complet. All items likehose set nipple, washer, ball valve, Gland having high purity with lubricantalinment of pump and motor etc shall be deemed to be included in repair.Record shall be maintained in register duly singed by Engr-in-Charge |
| 76 | M&L for routine/Preventive maint of pump / motor set complete of size 12.5 to 20 HP. SKF high performance, high temperature superior quality pump & motor bearing grease of model - SKF LG HP 2/18 or equivalant quality of make castrol / Valvoline etc, nut / bolts, complete with repair / replacment of unsv acessories like cooling pipe/ drain pipe, washer,etc complet. All items likehose set nipple, washer, ball valve, Gland having high purity with lubricantalinment of pump and motor etc shall be deemed to be included in repair.Record shall be maintained in register duly singed by Engr-in-Charge |
| 77 | M&L for routine/Preventive maint of pump / motor set complete of size 10 to 03 HP. SKF high performance, high temperature superior quality pump & motor bearing grease of model - SKF LG HP 2/18 or equivalant quality of make castrol / Valvoline etc, nut / bolts, complete with repair / replacment of unsv acessories like cooling pipe/ drain pipe, washer,etc complet. All items likehose set nipple, washer, ball valve, Gland having high purity with lubricantalinment of pump and motor etc shall be deemed to be included in repair.Record shall be maintained in register duly singed by Engr-in-Charge |
| 78 | Material and labour for Gland fiiling having high purity with lubricant of suitable size & suitable for high speed, high temprature and high pressure application. |
| 79 | M&L for strip opening of submersible mono blockpump motor of capacity 03 to 05 HP, rewinding with PVC copper wire winding wire of existing size with insulated paper / bamboo clipsempire tape / glass tape etc,tesing after completion of job. (Make of winding wire :- Finolex,PMC,sarunda |
| 80 | M&L for strip opening of submersible mono blockpump motor of capacity 10 to 12 HP, rewinding with PVC copper wire winding wire of existing size with insulated paper / bamboo clipsempire tape / glass tape etc,tesing after completion of job. (Make of winding wire :- Finolex,PMC,sarunda |
| 81 | S&F in replacemnt of Bush of mono block submersible pump 03 to 05 HP |
| 82 | S&F in replacemnt of Bush of mono block submersible pump 10 to 12 HP |
| 83 | M&L for repair ofcentrifugal pump of Capicity100 to 150 HP strip opening ofcasing of pumping set. for checking of defective parts Repair / replacement of unsv parts & reassembling the same & testing after completion of work. cost of gasket and minor parts like nut bolt and washer etc is deemed to be included in quoted rates, Spare parts shall be measured & paid seperately here-in-after, as directed by Engr-in-Charge. |
| 84 | Supply and fixing in replacement of impellor C.I.with all acessories for pumping set capacity of 100 to 150 HP pumping set. |
| 85 | Supply and fixing in replacement of impellerWearing Ring C .I. as per existing of capacity of 100 to 150 HP pumping set. |
| 86 | Supply and fixing in replacement of impeller CasingRing C .I. as per existing of capacity of 100 to 150 HP pumping set. |
| 87 | Supply and fixing in replacement of shaft Sleeve/bush C.I. as per existing of capacity of 100 to 150 HP pumping set. |
| 88 | Supply and Fixing in Replacement of NDE/DE pump bearing as per existing size, type, of capicity 100 to 150 HP. |
| 89 | Supply and fixing in replacement of Gland plate CI capacity of 100 to 150 HP pumping set. |
| 90 | M&L for straightening of Pump shaftincluding filling/welding cutting of existing size and leath work for pump as per existing size, type, make & model.capacity of 100 to 150 HP pumping set. |
| 91 | M&L for repair ofcentrifugal pump of Capicity50 to 75 HP strip opening ofcasing of pumping set. for checking of defective parts Repair / replacement of unsv parts & reassembling the same & testing after completion of work. cost of gasket and minor parts like nut bolt and washer etc is deemed to be included in quoted rates, Spare parts shall be measured & paid seperately here-in-after, as directed by Engr-in-Charge. |
| 92 | Supply and fixing in replacement of impellor C.I.with all acessories for centrifugal pumping set capacity of 50 to 75 HP pumping set. |
| 93 | Supply and fixing in replacement of impellerWearing Ring C .I. as per existing of capacity of 50 to 75 HP centrifugalpumping set. |
| 94 | Supply and fixing in replacement of impeller CasingRing C .I. as per existing of capacity of 50 to 75 HP centrifugal pumping set. |
| 95 | Supply and fixing in replacement of shaft Sleeve/Bush C.I. as per existing of capacity of 50 to 75 HP centrifugal pumping set. |
| 96 | Supply and Fixing in Replacement of NDE/DE pump bearing as per existing size, type, of capicity 50 to 75 HP,centrifugal pump set. |
| 97 | Supply and fixing in replacement of Gland plate CI capacity of 50 to 75 HP centrifugalpumping set. |
| 98 | M&L for straightening of Pump shaftincluding filling,welding,cutting of existing size and lathe work for pump as per existing size, type, make & model.capacity of 50 to 75 HP pumping set. |
| 99 | M&L for repair ofcentrifugal pump of Capicity10 to 15 HP strip opening ofcasing of pumping set. for checking of defective parts Repair / replacement of unsv parts & reassembling the same & testing after completion of work. cost of gasket and minor parts like nut bolt and washer etc is deemed to be included in quoted rates, Spare parts shall be measured & paid seperately here-in-after, as directed by Engr-in-Charge. |
| 100 | Supply and fixing in replacement of impellor C.I.with all acessories for centrifugal pumping set capacity of 10 to 15 HP pumping set. |
| 101 | Supply and fixing in replacement of impellerWearing Ring C .I. as per existing of capacity of 10 to 15 HP pumping set. |
| 102 | Supply and fixing in replacement of shaft Sleeve/Bush C.I. as per existing of capacity of 10 to 15 HP pumping set. |
| 103 | Supply and Fixing in Replacement of NDE/DE pump bearing as per existing size, type, of capicity 10 to 15 HP. |
| 104 | Supply and fixing in replacement of Gland plate CI capacity of 10 to 15 HP pumping set. |
| 105 | Replacement of mechnical seal for capacity 10 to 15 HP |
| 106 | M&L for straightening of Pump shaftincluding filling,welding,cutting of existing size and leath work for pump as per existing size, type, make & model.capacity of 10 to 15 HP pumping set. |
| 107 | M&L for repair ofcentrifugal pump of Capicity5 to 7.5 HP strip opening ofcasing of pumping set. for checking of defective parts Repair / replacement of unsv parts & reassembling the same & testing after completion of work. cost of gasket and minor parts like nut bolt and washer etc is deemed to be included in quoted rates, Spare parts shall be measured & paid seperately here-in-after, as directed by Engr-in-Charge. |
| 108 | M&L for Replacement of CI impellor with all acessories for pumping set upto the capacity of 5 to 7.5HP pumping set. |
| 109 | M&L for Replacement of NDE/DEbearing as per existing size, type, make & model.of capicity 5 to 7.5 HP HP |
| 110 | Supply and fixing in replacement of Gland plate CI capacity of 5 to 7.5HP pumping set. |
| 111 | M&L for Replacement of mechnical seal for capacity 5 to 7.5HP |
| 112 | M&L for straightening of Pump shaftincluding filling,welding,cutting of existing size and leath work for pump as per existing size, type, make & model.capacity of 5 to 7.5HP pumping set. |
| 113 | M&L for repair ofcentrifugal pump of Capicity1.0 to 3.0 HP strip opening ofcasing of pumping set. for checking of defective parts Repair / replacement of unsv parts & reassembling the same & testing after completion of work. cost of gasket and minor parts like nut bolt and washer etc is deemed to be included in quoted rates, Spare parts shall be measured & paid seperately here-in-after, as directed by Engr-in-Charge. |
| 114 | Replacement of impellor with all acessories for pumping set upto the capacity of 1.0 to 3.0 HP pumping set. |
| 115 | Replacement of NDE/DEbearing as per existing size, type, make & model.of capicity 1.0 to 3.0 |
| 116 | Replacement of mechnical seal for capacity 1.0 to 3.0 HP |
| 117 | M&L for straightening of Pump shaftincluding filling,welding,cutting of existing size and leath work for pump as per existing size, type, make & model.capacity of 1.0 to 3.0 HP pumping set. |
| 118 | M&L for strip opening of electric motor after electrically disconnecting 100 to 150 HP pump for rewinding / replacement of unsv parts & reassembling the same & testing on load at existing place in presence of Engr-in-Charge. transporting from wk place to wksp & wksp to wk place shall be deemed to be included, all other spare parts / rewinding wk, material shall be measured and paid seperately here-in-after. All as directed by Engr-in-Charge. |
| 119 | Rewinding of motor of capacity 150 HP with superenamelled pre-insulationed copper winding wire of existing size of copper wire with insulated paper / bamboo chips, empire tape / glass tape etc & tesing after completion of job. |
| 120 | Rewinding of motor of capacity 100 HP with superenamelled pre-insulationed copper winding wire of existing size of copper wire with insulated paper / bamboo chips, empire tape / glass tape etc & tesing after completion of job. |
| 121 | Replacement of NDE/DE bearing of Motor as per existing size, type, make & model. Of Capicity 100HP to 150 HP |
| 122 | Replacement of cooling fan of motor as per existing size, type, make & model. Of Capicity 100HP to 150 HP |
| 123 | M&L for strip opening of electric motor after electrically disconnecting 50 to 75 HP pump for rewinding / replacement of unsv parts & reassembling the same & testing on load at existing place in presence of Engr-in-Charge. transporting from wk place to wksp & wksp to wk place shall be deemed to be included, all other spare parts / rewinding wk, material shall be measured and paid seperately here-in-after. All as directed by Engr-in-Charge. |
| 124 | Rewinding of motor of capacity 75 HP with superenamelled pre-insulationed copper winding wire of existing size of copper wire with insulated paper / bamboo chips, empire tape / glass tape etc & tesing after completion of job. |
| 125 | Rewinding of motor of capacity 50 HP with superenamelled pre-insulationed copper winding wire of existing size of copper wire with insulated paper / bamboo chips, empire tape / glass tape etc & tesing after completion of job. |
| 126 | Replacement of NDE/DE bearing of motor as per existing size, type, make & model. Of Capicity 75HP to 50 HP |
| 127 | Replacement of motor cooling fan as per existing size, type, make & model. Of Capicity 75HP to 50 HP |
| 128 | M&L for strip opening of electric motor after electrically disconnecting 10 to 20 HP pump for rewinding / replacement of unsv parts & reassembling the same & testing on load at existing place in presence of Engr-in-Charge. transporting from wk place to wksp & wksp to wk place shall be deemed to be included, all other spare parts / rewinding wk, material shall be measured and paid seperately here-in-after. All as directed by Engr-in-Charge. |
| 129 | Rewinding of motor of capacity 20HP with superenamelled pre-insulationed copper winding wire of existing size of copper wire with insulated paper / bamboo chips, empire tape / glass tape etc & tesing after completion of job. |
| 130 | Rewinding of motor of capacity 15 HP with superenamelled pre-insulationed copper winding wire of existing size of copper wire with insulated paper / bamboo chips, empire tape / glass tape etc & tesing after completion of job. |
| 131 | Rewinding of motor of capacity 12.5HP with superenamelled pre-insulationed copper winding wire of existing size of copper wire with insulated paper / bamboo chips, empire tape / glass tape etc & tesing after completion of job. |
| 132 | Rewinding of motor of capacity 10HP with superenamelled pre-insulationed copper winding wire of existing size of copper wire with insulated paper / bamboo chips, empire tape / glass tape etc & tesing after completion of job. |
| 133 | Replacement of NDE/DE bearing of motor as per existing size, type, make & model. Of Capicity 10HP to 15 HP |
| 134 | Replacement of NDE/DE bearing of motor as per existing size, type, make & model. Of Capicity 20 HP |
| 135 | Replacement of cooling fan as per existing size, type, make & model. Of Capicity 10HP to 15 HP |
| 136 | Replacement of cooling fan as per existing size, type, make & model. Of Capacity 20 HP |
| 137 | M&L for strip opening of electric motor after electrically disconnecting 5 to 7.5 HP pump for rewinding / replacement of unsv parts & reassembling the same & testing on load at existing place in presence of Engr-in-Charge. transporting from wk place to wksp & wksp to wk place shall be deemed to be included, all other spare parts / rewinding wk, material shall be measured and paid seperately here-in-after. All as directed by Engr-in-Charge. |
| 138 | Rewinding of motor of capacity 7.5 HPwith superenamelled pre-insulationed copper winding wire of existing size of copper wire with insulated paper / bamboo chips, empire tape / glass tape etc & tesing after completion of job. |
| 139 | Rewinding of motor of capacity05 HP with superenamelled pre-insulationed copper winding wire of existing size of copper wire with insulated paper / bamboo chips, empire tape / glass tape etc & tesing after completion of job. |
| 140 | Replacement of NDE/DE bearing of motor as per existing size, type, make & model. Of Capicity 7.5HP to 05 HP |
| 141 | Replacement of cooling fanof motor as per existing size, type, make & model. Of Capicity 7.5HP to 05 HP |
| 142 | M&L for strip opening of electric motor after electrically disconnecting 1 to 3.0 HP pump for rewinding / replacement of unsv parts & reassembling the same & testing on load at existing place in presence of Engr-in-Charge. transporting from wk place to wksp & wksp to wk place shall be deemed to be included, all other spare parts / rewinding wk, material shall be measured and paid seperately here-in-after. All as directed by Engr-in-Charge. |
| 143 | Rewinding of motor of capacity 03 HP with superenamelled pre-insulationed copper winding wire of existing size of copper wire with insulated paper / bamboo chips, empire tape / glass tape etc & tesing after completion of job. |
| 144 | Rewinding of motor of capacity02 HP with superenamelled pre-insulationed copper winding wire of existing size of copper wire with insulated paper / bamboo chips, empire tape / glass tape etc & tesing after completion of job. |
| 145 | Rewinding of motor of capacity 1.5 HPwith superenamelled pre-insulationed copper winding wire of existing size of copper wire with insulated paper / bamboo chips, empire tape / glass tape etc & tesing after completion of job. |
| 146 | Rewinding of motor of capacity01 HP with superenamelled pre-insulationed copper winding wire of existing size of copper wire with insulated paper / bamboo chips, empire tape / glass tape etc & tesing after completion of job. |
| 147 | Replacement of NDE/DE bearing as per existing size, type, make & model. Of Capicity 1HP to 3.0HP |
| 148 | Replacement of cooling fan as per existing size, type, make & model. Of Capicity 1HP to 3.0 HP |
| 149 | Hiring of JCB/ Cranes with operator & fuelfor mechanical work at site / as spl task work as and when demanded, record shall be maintained for hours run on register and duly signed by Engr-in-Charge. |
| 150 | M&L for replacement of digital voltmeter for 3 ph 440 V, accuracy class 1.0,input voltage range 50-520VAC,Aux supply 80-300VAC, CT Secondary site selectable 1A/5A, Flush mounting 96x96mm, inbuilt selector switch for 3 phase meter , CT/PT site programablecatpart No WL 112010oooo make L&T or Eqvt |
| 151 | S&F Ammeter selector switch Line current (R,Y,B, with OFF) with CT 16 Amp , Cat part No 61325 SCB03TDYR Make - L&Tor Eqvt in |
| 152 | S&F voltmeter selector switch to measure voltage between phase (BR,YB,RY with OFF) 16A, Cat part No 61312 SCB03TDYR Make - L&Tor Eqvt |
| 153 | S&F LED Decorative post top light 20W withIP65 protectionelegantly designed spun aluminium and high grade aluminium heat sink for efficient thermal management, sturdiness and excellent corrosion resistance. MS base provided to support the housing. Powder coated black after phosphocromate treatment : |
| 154 | M&L for rewinding theexhaust fan of any make with super enamelled copper wire of suitable for incl all insulating materials varnishing complete incl satisfactory test run on load complete for 300 mm/450mmsweep exhaust fan any make |
| 155 | Supply and fix in repair D shine MCCB for motor backup protection 3 Polerated 400 Amps,breaking capacity 50 KA. Ics = 100% ICUIncluding Spreader Link between phase Cat part No CM94516OOROOG Model/Type DN3-400M, Make- L&T, or Cat part No XF3H400PV, Make- BCH, or equivalant model in seimens |
| 156 | Supply and fix in repair D shine MCCB for motor backup protection 3 Polerated 250 Amps,breaking capacity 50 KA. Ics = 100% ICU Including Spreader Link between phaseCat part No CM92171OOPOOG, Model/Type DN2-250M, Make- L&T, or Cat part No XF2H250PV, Make- BCH, or equivalant model in seimens |
| 157 | Supply and fix in repair D shine MCCB for motor backup protection 3 Polerated 160 Amps,breaking capacity 50 KA Ics = 100% ICU Including Spreader Link between phase . Cat part No DZ1T0160NXM1A , Model/Type DZ1-160M, Make- L&T, or Cat part No XF2H160PV Make- BCH, or equivalant model in seimens |
| 158 | Supply and fix in repair D shine MCCB for motor backup protection 4 Polerated 125 Amps,breaking capacity 50 KA Ics = 100% ICU . Including seperator between phaseCat part No DZ1T0125NXM1A , Model/Type DZ1-160M, Make- L&T, or Cat part No XF2H125PV Make- BCH, or equivalant model in seimens |
| 159 | M&L for preparation of old painted surface of pipe lines, railing etc and protect meters,switches,moving parts from paintingand paint with spray gunwith one coat of existing colour complete all as specified and directed. |
| 160 | Disconnecting of all electrical connection, M&L for prepraction of old painted surface with the help of paint remover,scrapper & fine ambery paper and painting with two coat of heat resistance paint with the help of spray gun overone coat of red oxide and writing SM No/ Machine No and connect back all electrical connections complete all as specified and directed onCapicity 00 to 150 HP.Pump set (Motor+Pump+ Foundation Frame) |
| 161 | All as per Item Ser No 143 above but for capacity 50 to 75 HP |
| 162 | All as per Item Ser No 143 above but for capacity 10 to 20 HP |
| 163 | Supply and laying XLPE insulated unsheathed multi stranded copper conductor cable 1100 volts grade single core of sizes(a) 95 sq mm from LT panel to starter and starter to motor, complete laid in floor/wall or cable duct all as directed. |
| 164 | All as per Item Ser No 144 above but for size 70 sq mm |
| 165 | All as per Item Ser No 144 above but for size 25 sq mm |
| 166 | All as per Item Ser No 144 above but for size16 sq mm |
| 167 | S&F in replacement of chlorine test kit complete with box all as directed by EIC |
| 168 | M&L for replacement in earthing complete with galvanized steel earth plate electrode, 60Cm X60 Cm X 6.0 mm thick, buried directly in ground (earth pit not less than 2.25 Mtr deep below ground level) with top edge of the earth plate not less than 1.5 Mtr below normal ground level, connected to galvanized earth strip 32x6 mm by means of galvanised iron or steel with 40mm dia GI pipe light grade for protection of earth strip and all as shown in electrical plate No. 3 connected to elelctrical equipments all as specified or indicated including Exc & earth work, constn of PCC pit with RCC cover, watering pipe 20mm dia light grade with funnel & wire mesh &testing on completion all as directed.cost of earth strip of size 32x6mm up to 7.5 mtr deemed to be included in the rate quoted by contactor |
| 169 | Supply and fix GI earth strip of size 32x6mm |
| 170 | M & L for Replacementof existing filter media consisting of gravel and sand in water purification plant having working pressure 25 PSI H. Pn 50 PSIat senapati Bhawan as per details given below all as directed by Engr-in-Charge. (a) Removing the existing filter media consisting of gravels and sand, spreading and leveling out side for refilling, cleaning the surface, walls, bed sand Nozzles with wire brushes and cleaning the walls with bleaching powder solution, washing with fresh water and finally washing the complete filter bed twice with Anti bacterial spray treatmentin all respect, and cleaning with high pressure water nozzle sprayetc complete.(b)Refilling the filter media in the filter bed, gravels (pebbles) removed from the existing filter media after the washing pebbles with 5%( Dil)Diluted aquous solution of Hydrochloric Acid (HCL) and treatment with 10% ( Dil)Diluted aquoussolution of NAOH (sodium Hydro Oxide) and laying and stacking in different layers into filter beds.(c) Painting of complete filter assembly including incoming and outgoing pipe with two coat of synthetic enamel paint after scraping the old surface. |
| 171 | M & L for Replacementof existing filter media consisting of gravel and sand in filter bed tank having filtration capacity 32 lakh ltr /12 hrs at swimming poolas per details given below all as directed by Engr-in-Charge. (a) Removing the existing filter media consisting of gravels and sand, spreading and leveling out side for refilling, cleaning the surface, walls, bed sand Nozzles with wire brushes and cleaning the walls with bleaching powder solution, washing with fresh water and finally washing the complete filter bed twice with Anti bacterial spraycomplete in all respect, Anti bacterial spray with high pressure water nozzle spray cleaning etc complete.(b)Refilling the filter media in the filter bed, gravels (pebbles) removed from the existing filter media after the washing pebbles with 5% (Dil) Diluted aqous solution of Hydrochloric Acid (HCL) and treatment with 10% (Dil) Diluted aqous solution of NAOH (sodium Hydro Oxide) and laying and stacking in different layers into filter beds.(c) Painting of complete filter assembly including incoming and outgoing pipe with two coat of synthetic enamel paint after scraping the old surface. |
| 172 | Supply and filling filter media conisting of screened graded sand on supporting gravel bed of size 0.5 to 1.5 mm to suit existing size and type all as spd and directed |
| 173 | Supply and laying pebbles 8 mm to 25 mm in different sizes to suit existing size and type all as spd and directed . |
| 174 | Supply and laying pebbles upto 6 mm in different sizes to suit existing size and type all as spd and directed. |
| 175 | Supply and fixing Mild steel or iron work in heavy size for Fabricate of foundation Base frame for Pumps and motor including drilling holes riveting or welding where necessary and their fixing required for proper completion of work |
| 176 | S&F in replacement of factory made 1-Phase DOL with 2P CPG Contactor & 2P Overload Relay DOL motor starter suitable for 2 HP motorcomplete with start stop push buttons powder coated enclosure with PU gaskets consisting of 1Ø, 220V, 50Hz,Overload Relay Range13.2 - 20.0 (A) Contactor Type 2P CPG,Contactor Rating 25A,Make BCH model HSN: 8536 cat code NALBW-SP or equivalent |
| 177 | S&F in replacement of DOL submersible pump motor starter 3-PHcomplete powder coated enclosure with PU gaskets with protection consisting of,phase failure , phase imblance, phase reversal, short circuit protection, ammeter, voltmeter,ON/ OFF and trip indication, dry run preventor, start stop push buttons,Overload Relay Range 13 - 20.0 (A),Contactor Rating 20A, with coil voltage 380-415V Make BCHHSN code: 8536, model type SHAKTI P10 cat code CPEYSBL or equivalent |
| 178 | Supply and laying in replecement XLPE insulated, armoured heavy duty electric cable multi strand aluminium conductor, 1100 Volts Grade cross section area2 Core 6 Sqmm |
| 179 | Excavation in trenches not exc 1.5m widthand not exc1.5 min depth and getting out forlaying of pipes etc in soft/loose soil . |
| 180 | Returning filling in including spreading levelling watering and ramming in layers not exceeding 25 cm in any type of soil. |
| 181 | Removing of excavated surplus soil to a distance not exceeding50M where directed and at a level not exceeding 1.5 M above the starting point. |
| 182 | Material and labour for sand cushioning to underground cable screened un-washed river sand and punning for cushioning as per technical data to the cable all as specified and as directed by EIC. |
| 183 | supplying and laying of precast concrete cable cover class LV, type 1, flat size 250mmx150mmx40mm and abutting each other with gap between adjacent precast concrete cable cover not exceeding 10mm over underground cable for protection. |
| 184 | Supply, laying, testing and commissioning of 25mm X 3mm Aluminium strip from existing earth pit to the panel/ motor, including earth work as required complete in all respect as directed by Engineer-in- Charge. |
| 185 | Supply and fixing in repair CI foot valve flanged/threaded type of dia 50 mm as per existing including accessories like nut-bolt, gasket etc as required complete in all respect as directed by Engineer-in- Charge. |
| 186 | All as per Ser item No 163 above but for dia of foot valve 80 mm |
| 187 | All as per Ser item No 163 above but for dia of foot valve 100 mm |
| 188 | Material and labour for maintenance of complete scada system of water Supplywith all Slave panels , PLC panels around 24 places under GE (A) Utility like, greasing and cleaning of actuator,cleaning and checking connection of Magnetic float sensor, cleaning and setting of solenoid Valve,cleaning and setting of pressure switch, setting of limit/torque switch, checking and repalcement of minor parts like ferrule/lugs and tighten the loose electrical connection , replacement of unserviceable nut, bolt and key etc and kept record as per format provided in register and put to Engr-in charge at every month , replacement of u/s spare parts shall be measured and paid separately. all as directed by Engr-in-Charge. Note - Rate of all sundry item like waste cloth, grease, ferrule/Lugs, nut , bolt , key andtools required for servicing etc shall be deemed to be included in the rate quoted by contactor. if contactor fails to carry out servicing every month an amount of Rs 2500/months shall be deducted from the payment due to contractor |
| 189 | Supply and fix in replacement of SMPS unit suitable for out put24 volt DCand input 230 volt AC of rating 6.5 Amp as per exiting sample/ size Make: Schneider/NHP or equivalent make |
| 190 | Supply and fix in replacement ofsingle phase preventor /single phase relay as per modelVSP D 2 / VSP3 type or as per exiting sample/ size having system ACaux supply 415 volt50 HZMake : - Minilac/Indo Power /Schnieder/L&T |
| 191 | Supply and fix in replacement ofrelay pin type 4C/O , 220 -240Volt AC or as per exiting Make : LEONE / IDEC/L&T/Schneider |
| 192 | Supply and fix in replacement ofrelay pin type 4C/O , 24 Volt DC or as per exitingMake : LEONE / IDEC/L&T/Schneider |
| 193 | Supply and fix in replacement of indicator lamps of colour red / green/ yellowas per exiting sample/ size Make : ESBEE / Schneider /L&T or equivalent make |
| 194 | Supply and fix in replacement of push button with Led indicator red/ green type -240 Volt Ac as per exiting sample/ size Make : ESBEE / Schneider / L&T |
| 195 | Supply and fix in replacement Wireless Communication Modem including Reprogramming with suitable patch cord and mounting accessories compatible with existing system (at Security Section, SMC & Spare) for communication to the Slave Panel as well as SCADA system.Make : Motorola / Maestro / visiontek/ as per sample to suit existing systemand ensure proper serviceability. |
| 196 | Supply and fix in replacement of Water Level Controller Relay Card (10 levels)Make : As per sample to suit existing system and ensure perfect serviceabilty. |
| 197 | Supply and fix in replacement ofWater Level Controller Relay Card (05 levels)Make : AAs per sample to suit existing system and ensure perfect serviceabilty. |
| 198 | Supply and fix in replacement of Pressure Switch 0 – 10 Kg/sq.cm.Make: Indfos/Danfoss/L&T/Honeywell |
| 199 | Supply and fix in replacement ofSolenoid Valve - 10mm, 230 V , 50HZ AC.Make : ROTEX/AVCON/JOHNSON CONTROL/DANFOS |
| 200 | Supply and fix in replacement of MCB 16 Amps, 415 V,10KA, TPN, \"C\" curve, Make- Havells, Legrand,schneider |
| 201 | Supply and fixin replacement of MCB SPN 10 Amps, 230V,10KA, SPN, \"C\" curve, Make- Havells, Legrand,schneider |
| 202 | Supply and fix in replacement of CI Butterfly valve of size 80 mm dia. PN 16 suitable for couple with Existing actuator operation rate for modification in adopter to make fit with existing actuator shall be deemed to be included in rate quoted by contactor.Make: AUDCO/L&T/VIRGO/BVI |
| 203 | Supply and fix in replacement ofCI Butterfly valve of size 100 mm dia.PN 16 suitable for couple with Existing actuator operation rate formodification in adopter to make fit with existing actuator shall be deemed to be included in rate quoted by contactor.Make: AUDCO/L&T/VIRGO/BVI |
| 204 | Supply and fix in replacement of CI Butterfly valve of size 150 mm dia.PN 16 suitable for couple with Existing actuator operation rate for modification in adopter to make fit with existing actuator shall be deemed to be included in rate quoted by contactor.Make : AUDCO/L&T/VIRGO/BVI |
| 205 | Supply and fix in repalacement of CI Butterfly valve of size 200 mm dia.PN 16 suitable for couple with Existing actuator operation rate for modification in adopter to make fit with existing actuator shall be deemed to be included in rate quoted by contactor.Make:AUDCO/L&T/VIRGO/BVI |
| 206 | Supply and fix in replacement ofCI Butterfly valve of size 250 mm dia.PN 16 suitable for couple with Existing actuator operation rate for modification in adopter to make fit with existing actuator shall be deemed to be included in rate quoted by contactor.Make:AUDCO/L&T/VIRGO/BVI/Zoloto |
| 207 | Supply and fix in replacement of CI Butterfly valve of size 300 mm dia PN 16 suitable forcouple with Existing actuator operation rate for minor modification in adopter to make fit with existing actuator shall be deemed to be included in rate quoted by contactor.Make: AUDCO/L&T/VIRGO/BVI |
| 208 | Supply and fix in replacement of Capicotor 7 UF for Actuator suitable for 80mm/100mm/150mm dia Butterfly Valve actuator |
| 209 | Supply and fix in replacement of Capicotor 10UF for Actuator suitable for 200mm/250mm/300mm dia Butterfly Valve actuator |
| 210 | Supply and fix in replacement of Limit Switch ( Micro Switches) for Actuator suitable for 300mm/250mm/200mm/150mm/100mm/80mm dia Butterfly Valve Make :As per sample to suit existing size, type and model system |
| 211 | Supply and fix in replacement of torque Limit Switch With 2 NO +2NCfor Actuator suitable for 400mm dia Butterfly Valve Make :As per sample to suit existing size, type and model system |
| 212 | Supply & Laying 5 pair 0.5 sqmm dia.armoured comunication cable with copper conductor for sensor. Make: DELTON/Polycab/FSC/FINOLEX/Havells |
| 213 | Supply & Laying7 Core 1.5 sq. mm PVC sheath PVC insulated copper conductor armoured cable.Make:DELTON/Polycab/FSC/FINOLEX/Havells |
| 214 | Supply & Laying2 Core 1.5 sq. mm PVC sheath PVC insulated copper conductor armoured cable.Make: DELTON/Polycab/FSC/FINOLEX/Havells |
| 215 | Taking downcarefully after disconnecting electrically to UNSVelectric motor 3 phaseofElectromechanical valves of size 400mm. Sytrip opening of motor replacement of completewinding withexisting size supiriour enamelled copperwinding wire, replacement ofbearingof NDE/ DEas per site , reassemblking and testingupto entire satisfaction of Engr-in-Charge. |
| 216 | Taking downcarefully after disconnecting electrically to UNSVelectric motor singlephaseofElectromechanical valves of size 300mm. Sytrip opening of motorreplacement of completewinding withexisting size supoer enamelled copperwinding wire, replacement ofbearibgof NDE/ DEas perstate , reassembling and testingupto entire satisfaction of Engr-in-Charge. |
| 217 | All as per Item No 192 above but for 250mm dia Electromechanical valves |
| 218 | All as per Item No 192 above but for 200mm dia Electromechanical valves |
| 219 | All as per Item No 192 above but for 150mm dia Electromechanical valves |
| 220 | All as per Item No 192 above but for 100mm dia Electromechanical valves |
| 221 | All as per Item No 192 above but for 80mm dia Electromechanical valves |
| 222 | Supply and install Maintenance free 12V 18AH UPS BATTERY, suitable for 3000VA UPS MakeAMARON QUANTA Model No/Part NO-6161142813539 or Eqivalant in EXIDE,LUMINUS |
| 223 | Supply and Fixing in replacement of Rack/base plate of scada system modelP2918 • 8 1/0 Base Plate with AC 3 A PSU + CPU SlotsMake : Mitsubishi |
| 224 | Supply and fix in replacement of I/O Moduleexpansion adaptors, input / output/ communication ports / power supply : 24 V DC / permissible range : 20.4VDC to 28.8VDC with less than 10% ripple / I/O module / operating temperature :0 deg to 50 deg / storage temperature : -20 deg to 60 deg andEstablish Communication between Slave Panel and SCADAmodel P2417A• 8 pt. 24 VDC Inputs (Inclusive of HSC1@ 20 KHz.HSC 2 @ 2 KHz. Inputs and frequency measurement ,2 KHz at Input 2)+ 8 pt. 24 VDC Outputs• 250 mAPer pt. (801 +800). Make : Mitsubishi |
| 225 | Reprogramming and established comunication with automation slave panel and main scada system installed at army cantt jodhpur pump houses for scada system as per existing system for smooth controllingof scada system including resetting of system: Note Downloading and uploading of the PLC programming shall be carried out in the presence of Engr-in charge |
| 226 | Supply and fixed in replacement of defected/ burn out /unsafe internal control wiring for automation main master panel or automation slave panel installed at variours pump house for scada system as per existing system by usingcopper bottle lugs, copper ferrule,including markingwith cable marking ferrule of the following Size(a)PVC insulated and unsheathed flame retardant Low smoke ( FRLS ) cable of 1.5 sqmm (nominal area) with multistranded copper conductor electric wire single core 1100 volts grade |
| 227 | All as srl item No. 204 above butPVC insulated and unsheathed flame retardant Low smoke ( FRLS ) cable of 0.5 sqmm (nominal area) with multistranded copper conductor electric wire single core 1100 volts grade |
| 228 | Supply and fix PVC Cable ducts with ROHS Compliant and FRLS of Size 60mmx45mm (HxW) grey in colour |
| 229 | Supply and fix as in replacement of mettalic body resistor for Actuator suitable for 300mm/250mm/200mm/150mm/100mm/80mm/dia butter fly valve actuator As per sample to suit existing size, type and system |
| 230 | Supplying and fixing as in replacement HMI (Human Machine Enterface) GT 21 Series 3.8\" TFT Monochrome,TFT LCD With 32 Gray Scale 24 vdc Builtin, RS 232, RS - 485 USB PORT interferance for PLC based Panel including reprogramming to suit with existing system completeall as directed by Engr-in charge . Make- Unitronics/Mitsubishi/Renu or Equivalent Make |
| 231 | supplying and fixing in replacement of comunication cable PLC to HMI port, including adopter panel to panel, panel to PC, control cable with M/F socket of existing pin fixed as in repair complete all as directed by Engr-in charge |
| 232 | Supply and fixing in replacement of 2/3 way Auto and Mannualslector switch for scada water supply system as per existing make and model fixed as in repair complete all as directed by Engr-in charge. |
| 233 | Supply and fixing in replacement of on/off slector switch for SCADA water supply system as per existing make and model fixed as in repair complete all as directed by Engr-in charge. |
| 234 | Servicing of Laser Jet Printer model-CP1025 color Make HP |
| 235 | Servicing of smart UPS 3000VAmake APC. |
| 236 | Supply and fix Solenoid Valve - 20 mm, 230 V , 50HZ AC.Make : ROTEX/AVCON/JOHNSON CONTROL/DANFOS |
| 237 | Supply and fix rust proof maintenance free single point Magnetic float/water level senser with float size 3 MTR water level sensor for OHT / UG sumps. Make RDS/ATS or Eqvt make as per existing |
| 238 | Supply and fix Electric motor suitable for actuator of 400mm dia Butterfly Valve, Make Ritetork or Eqvt |
| 239 | Supply and fix Electric motor suitable for actuator of 300mm dia Butterfly Valve, Make Ritetork or Eqvt |
| 240 | Supply and fix Electric motor suitable for actuator of 200mm dia Butterfly Valve, Make Ritetork or Eqvt |
| 241 | Supply and fix Electric motor suitable for actuator of 150mm dia Butterfly Valve, Make Ritetork or Eqvt |
| 242 | Supply and fix Electric motor suitable for actuator of 100mm dia Butterfly Valve, Make Ritetork or Eqvt |
| 243 | M&L for Making adopter to couple with existing actuator and butter fly valve for smooth function of 100mm to 400mm Electromechanical valves |
| 244 | Supply, Reprogramming and Fixing PLC (Programmable Logic Controller) with connected power supply system, I/O Module expansion adaptors,48 digital input /48 digital output / 2 communication ports 232/485 / power supply : 24 V DC / permissible range : 20.4VDC to 28.8VDC with less than 10% ripple / I/O module / operating temperature :0 deg to 50 deg / storage temperature : -20 deg to 60 deg and Establish Communication between operational PLC and communicational PLC . |
| 245 | Supply, Reprogramming and Fixing PLC (Programmable Logic Controller) with connected power supply system, I/O Module expansion adaptors, 8 digital input / 8 digital output /2 communication ports / power supply : 24 V DC / permissible range : 20.4VDC to 28.8VDC with less than 10% ripple / I/O module / operating temperature :0 deg to 50 deg / storage temperature : -20 deg to 60 deg and Establish Communication between Slave Panel and SCADA . |
| 246 | Supply and fixing in replacement of defected/ burn out /unsafe internal control wiring and connection for automation main master panel or automation slave panel installed at variours pump house for scada system as per existing system and including using by FR PVC insulated electric wire with copper conductor wiring having of single core of size 0.5 sqmm to 1.0 sqmm sub wiring as properly electrical connection for smooth controlling panel of scada system including resetting of system complete and testing all as specifed and directed by Engr-in-charge |
| 247 | Supply, Installation, Testing and Commissioning HMI - Touch screen, CH * 8 Line Display & 28 CH * 10 Line Display: LCD (Full Colour more then 50 Colour) USB PORT (232 to 485) interference for PLC based panel. |
Copyright © 2025 · All Rights Reserved. Terms of Usage | Privacy Policy