Tender For Renovation Of Existing Ground Floor And Construction Of First Floor Part With Electrification And Interior Work Of The Hospital Building At Daitari In The District Of Keonjhar, Balance Work., daitari-Odisha

Orissa Mining Corporation Limited has published Tender For Renovation Of Existing Ground Floor And Construction Of First Floor Part With Electrification And Interior Work Of The Hospital Building At Daitari In The District Of Keonjhar, Balance Work.. Submission Date for this Tender is 22-08-2023. Electrification Work Tenders in daitari Odisha. Bidders can get complete Tender details and download the document.




Tender Notice

39039851
Tender For Renovation Of Existing Ground Floor And Construction Of First Floor Part With Electrification And Interior Work Of The Hospital Building At Daitari In The District Of Keonjhar, Balance Work.
Open Tender
Indian
Odisha
daitari
22-08-2023

Tender Details

Renovation Of Existing Ground Floor And Construction Of First Floor Part With Electrification And Interior Work Of The Hospital Building At Daitari In The District Of Keonjhar, Balance Work.

Key Value

Document Fees
INR 11800 /-
EMD
INR 115700.0 /-
Tender Value
INR 1.15 Crore /-

BOQ Items

Name of Work: Renovation of existing Ground Floor and Construction of First Floor (Part) with Electrification and Interior work of the Hospital Building at Daitari in the district of Keonjhar (Balance work).
Sl. No. Item Description
1Civil Works
2Earth work in excavation of foundation trenches in all kinds of soil including moorum, stony earth and earth mixed with boulders (except sheet rocks and boulders requiring for blasting) including dressing and leveling the bed up to the required depth and depositing the excavated materials at places away from the work site with all leads and lifts, T&P shoring and shuttering and dewatering if required etc. comp as directed by EIC.
3Filling foundation trenches and plinth with excavated earth including laying the earth in layers not exceeding 23.5cm (9”) thick ramming and watering with all leads and lifts including cost of all labour, T&P etc. complete as directed by the Engineer-in-charge.
4Supplying and filling the Foundation & Plinth with clean coarse river sand of approved quality from approved quarry, laying in layers not exceeding 150mm thick, watering and ramming including cost, conveyance, royalty and taxes of all materials, cost of all labour, T&P etc. as required for the work complete as per direction of the Engineer-in-charge.
5Supplying, diluting and preparing chemical emulsion like CHLORPYRIPHOS or other chemicals approved by Central Insecticides Board or as directed by the manufacturer and spraying the mixture uniformly by sprayer as pre-constructional anti termite treatment and creating a chemical barrier under and around the column pits, wall trenches, basement excavation, top surface of plinth filling, junction of walls and floors along with external perimeter of the building, expansion joints, surrounding the pipes and conduits etc. complete at the rate of 7.5 liters (or as directed by the manufacturer) per sqm on vertical and 5.0 liters per sqm on horizontal surfaces, 50% of the emulsion to be filled in the holes made in trenches at 150mm center to center etc.complete as per IS:6313 / 1981 (Part-II) and asper the direction of theEngineer-in-charge including cost of all materials, labour, taxes, etc. complete. (plinth area of the building at ground floor only shall be measured for payment).
6Providing & laying cement concrete of prop. (1:3:6) in foundation bed and floors using 40mm nominal size down graded, screened, washed hard black crusher broken granite metal of approved quality & from approved quarry including laying in the layers not exceeding 100 mm thick, hoisting, lowering, laying, watering and curing etc. complete to the required levels including cost, conveyance, royalty and taxes of all materials, cost of all labour, T&P etc. as required for the work complete and as per direction of Engineer-in-charge.
7Fly ash Brick masonry usingbricks of size 25cm. x 12 cm. x 8 cm. having crushing strength not less than 75 kg. Per. Sqr. Cm. in cement mortar of mix( 1:6) with ordinary Portland slag cement(PSC) and screened & washed sand for mortar after immersing the bricks for 6 (Six) hours in water before use in Foundation & Plinth including splays cutting, circular moulding, corbelling, chamfering and similar such type of works, watering and curing etc. including cost, conveyance, loading, unloading, royalties and taxes of all materials, cost of all labour, scaffolding, sundries, T&P required for the works etc. complete in all respect as directed by the Engineer-In-Charge. at all floors and all heights.
8Fly ash brick masonry in C.M.(1:6) after immersing the bricks having minimum crushing strength of 75 Kg/Cm2 in water for 24 hours having size of 25cmx12cmx8cm in superstructurewith ornamental molding and other similar type of works with all necessary projections, splays corbelling, cutting, champering, including cost conveyance, royalties of all materials, cost of all labour, T&P required for the work etc. compl. in all respect as per direction of EIC. Ground Floor
9Fly ash brick masonry in C.M.(1:6) after immersing the bricks having minimum crushing strength of 75 Kg/Cm2 in water for 24 hours having size of 25cmx12cmx8cm in superstructurewith ornamental molding and other similar type of works with all necessary projections, splays corbelling, cutting, champering, including cost conveyance, royalties of all materials, cost of all labour, T&P required for the work etc. compl. in all respect as per direction of EIC.in1st Floor
10Fly ash brick masonry in C.M.(1:4) after immersing the bricks having minimum crushing strength of 75 Kg/Cm2 in water for 24 hours having size of 25cmx12cmx8cm in superstructurewith ornamental molding and other similar type of works with all necessary projections, splays corbelling, cutting, champering, including cost conveyance, royalties of all materials, cost of all labour, T&P required for the work etc. compl. in all respect as per direction of EIC.Ground Floor
11Fly ash brick masonry in C.M.(1:4) after immersing the bricks having minimum crushing strength of 75 Kg/Cm2 in water for 24 hours having size of 25cmx12cmx8cm in superstructurewith ornamental molding and other similar type of works with all necessary projections, splays corbelling, cutting, champering, including cost conveyance, royalties of all materials, cost of all labour, T&P required for the work etc. compl. in all respect as per direction of EIC. in1st Floor
12R.C.C M-25 grade concrete with20mm & down graded hard crusher broken granite chips including hoisting and laying concrete, watering and curing for three weeks centering and shuttering and finishing the exposed surfaces smooth, providing beads or grooves where necessary including cost, conveyance, royalty of all material, dismantling the centering, shuttering work after the period as specified by the EIC and cost of all labour, T&P required for the work comp. in all respect, excluding cost of reinforcement, binding wires and labour charges for bending, binding and tying the grills. in Footing
13R.C.C M-25 grade concrete with20mm & down graded hard crusher broken granite chips including hoisting and laying concrete, watering and curing for three weeks centering and shuttering and finishing the exposed surfaces smooth, providing beads or grooves where necessary including cost, conveyance, royalty of all material, dismantling the centering, shuttering work after the period as specified by the EIC and cost of all labour, T&P required for the work comp. in all respect, excluding cost of reinforcement, binding wires and labour charges for bending, binding and tying the grills. in Column G/F
14R.C.C M-25 grade concrete with20mm & down graded hard crusher broken granite chips including hoisting and laying concrete, watering and curing for three weeks centering and shuttering and finishing the exposed surfaces smooth, providing beads or grooves where necessary including cost, conveyance, royalty of all material, dismantling the centering, shuttering work after the period as specified by the EIC and cost of all labour, T&P required for the work comp. in all respect, excluding cost of reinforcement, binding wires and labour charges for bending, binding and tying the grills. in Column 1st Floor
15R.C.C M-25 grade concrete with20mm & down graded hard crusher broken granite chips including hoisting and laying concrete, watering and curing for three weeks centering and shuttering and finishing the exposed surfaces smooth, providing beads or grooves where necessary including cost, conveyance, royalty of all material, dismantling the centering, shuttering work after the period as specified by the EIC and cost of all labour, T&P required for the work comp. in all respect, excluding cost of reinforcement, binding wires and labour charges for bending, binding and tying the grills. in Lintel (G/F)
16R.C.C M-25 grade concrete with20mm & down graded hard crusher broken granite chips including hoisting and laying concrete, watering and curing for three weeks centering and shuttering and finishing the exposed surfaces smooth, providing beads or grooves where necessary including cost, conveyance, royalty of all material, dismantling the centering, shuttering work after the period as specified by the EIC and cost of all labour, T&P required for the work comp. in all respect, excluding cost of reinforcement, binding wires and labour charges for bending, binding and tying the grills. in Lintel.in1st Floor
17R.C.C M-25 grade concrete with20mm & down graded hard crusher broken granite chips including hoisting and laying concrete, watering and curing for three weeks centering and shuttering and finishing the exposed surfaces smooth, providing beads or grooves where necessary including cost, conveyance, royalty of all material, dismantling the centering, shuttering work after the period as specified by the EIC and cost of all labour, T&P required for the work comp. in all respect, excluding cost of reinforcement, binding wires and labour charges for bending, binding and tying the grills. in Roof Beam (G/F)
18R.C.C M-25 grade concrete with20mm & down graded hard crusher broken granite chips including hoisting and laying concrete, watering and curing for three weeks centering and shuttering and finishing the exposed surfaces smooth, providing beads or grooves where necessary including cost, conveyance, royalty of all material, dismantling the centering, shuttering work after the period as specified by the EIC and cost of all labour, T&P required for the work comp. in all respect, excluding cost of reinforcement, binding wires and labour charges for bending, binding and tying the grills. in Roof Beam.in1st Floor
19R.C.C M-25 grade concrete with20mm & down graded hard crusher broken granite chips including hoisting and laying concrete, watering and curing for three weeks centering and shuttering and finishing the exposed surfaces smooth, providing beads or grooves where necessary including cost, conveyance, royalty of all material, dismantling the centering, shuttering work after the period as specified by the EIC and cost of all labour, T&P required for the work comp. in all respect, excluding cost of reinforcement, binding wires and labour charges for bending, binding and tying the grills. in Roof Slab (G/F)
20Supplying HYSDbars of appd. Quality size and grade and cutting, bending, binding and tying the grills in proper position as required for the RCC workincluding cost, conveyance of HYSD bars (Fe500 D) and binding wires of 18 to 20 gauge and cost of labour, T&P required to comp. in all respectas directed by the EIC. (G/F)
21Supplying HYSDbars of appd. Quality size and grade and cutting, bending, binding and tying the grills in proper position as required for the RCC workincluding cost, conveyance of HYSD bars (Fe500 D) and binding wires of 18 to 20 gauge and cost of labour, T&P required to comp. in all respectas directed by the EIC. 1st Floor
2212mm (1/2") thick cement plaster (1:6) for finished smooth surface of brick walls after racking out the joints including watering and curing etc. comp. with cost conveyance, royalty of all materials and cost of all labour, T&P scaffolding required for the work complete as per the direction of EIC.(G/F)
2312mm (1/2") thick cement plaster (1:6) for finished smooth surface of brick walls after racking out the joints including watering and curing etc. comp. with cost conveyance, royalty of all materials and cost of all labour, T&P scaffolding required for the work complete as per the direction of EIC.in1st Floor
2416mm (5/8") thick cement plaster with (1:6) for finished smoothsurface of brick walls double layer if required after racking out the joints including watering and curing etc. Complete. with cost , conveyance, royalty of all materials and cost of all labours, T&P scaffolding required for the work complete as per direction of EIC. (G/F)
2516mm (5/8") thick cement plaster with (1:6) for finished smooth surface of brick walls double layer if required after racking out the joints including watering and curing etc. Complete. with cost , conveyance, royalty of all materials and cost of all labours, T&P scaffolding required for the work complete as per direction of EIC. 1st Floor
266mm thick cement plaster (1:4) to RCC surfaces/ ceiling finished smooth including closed deep chiping and slury treatment including watering and curing etc. Comp. with cost , conveyance, of all materials and cost of all labours, T&P scaffolding required for the work complete as per direction of EIC. (G/F)
276mm thick cement plaster (1:4) to RCC surfaces/ ceiling finished smooth including closed deep chiping and slury treatment including watering and curing etc. Comp. with cost , conveyance, of all materials and cost of all labours, T&P scaffolding required for the work complete as per direction of EIC.in1st Floor
28Supplying all materials, labour, T&P and fixing Vitrifiedfloor tile of size 600mmX1200mm on floors, treads, steps and landing on 25mm thick bed of cement mortar (1:4) (1 Cement : 4 sand) jointed with neat cement, slurry mixed with pigment to match the shades of tiles including rubbing and polishing complete as per specification and direction of EIC including cost, carriage of all materials, cost of all labour, T&P required to complete the work. (Make :- Kajaria / Somany / RAK) (G/F)
29Supplying all materials, labour, T&P and fixing Vitrifiedfloor tile of size 600mmX1200mm on floors, treads, steps and landing on 25mm thick bed of cement mortar (1:4) (1 Cement : 4 sand) jointed with neat cement, slurry mixed with pigment to match the shades of tiles including rubbing and polishing complete as per specification and direction of EIC including cost, carriage of all materials, cost of all labour, T&P required to complete the work. (Make :- Kajaria / Somany / RAK) 1st Floor
30Supplying all materials, labour, T&P and fixing Vitrified skirting tile of size 600mmX1200mm onon 25mm thick bed of cement mortar (1:4) (1 Cement : 4 sand) jointed with neat cement, slurry mixed with pigment to match the shades of tiles including rubbing and polishing complete as per specification and direction of EIC including cost, carriage of all materials, cost of all labour, T&P required to complete the work. (Make :- Kajaria / Somany / RAK) (G/F)
31Supplying all materials, labour, T&P and fixing Vitrified skirting tile of size 600mmX1200mm onon 25mm thick bed of cement mortar (1:4) (1 Cement : 4 sand) jointed with neat cement, slurry mixed with pigment to match the shades of tiles including rubbing and polishing complete as per specification and direction of EIC including cost, carriage of all materials, cost of all labour, T&P required to complete the work.(Make :- Kajaria/ Somany / RAK).in1st Floor
32Supplying all materials, labour, T&P and fixing Vitrifiedfloor tile of size 600mmX600mm on floors, treads, steps and landing on 25mm thick bed of cement mortar (1:4) (1 Cement : 4 sand) jointed with neat cement, slurry mixed with pigment to match the shades of tiles including rubbing and polishing complete as per specification and direction of EIC including cost, carriage of all materials, cost of all labour, T&P required to complete the work.(Make :- Kajaria / Somany / RAK) (G/F)
33Supplying all materials, labour, T&P and fixing Vitrifiedfloor tile of size 600mmX600mm on floors, treads, steps and landing on 25mm thick bed of cement mortar (1:4) (1 Cement : 4 sand) jointed with neat cement, slurry mixed with pigment to match the shades of tiles including rubbing and polishing complete as per specification and direction of EIC including cost, carriage of all materials, cost of all labour, T&P required to complete the work.(Make :- Kajaria/ Somany / RAK) 1st Floor
34Supplying all materials, labour, T&P and fixing Ceramic glazedwall tile 600mm x 300mm size of approved make to floor surface confirming to drawing and designs set in 20mm thick bed of Cement Mortar (1:3) (1Cement : 3Sand) to proper line and plumb including cutting to required size and shade and fixing at corner splays and cambers etc. and joined with neat cement slurry mixed with pigment to match the shade of tile including rubbing & polishing with cost, carriage, taxes of all materials and cost of all labour, T&P required to complete the work etc. complete as per specification and direction of EIC. (Tiles should be of RAK / Kajaria / Somany) (G/F)
35Supplying all materials, labour, T&P and fixing Ceramic glazedwall tile 600mm x 300mm size of approved make to floor surface confirming to drawing and designs set in 20mm thick bed of Cement Mortar (1:3) (1Cement : 3Sand) to proper line and plumb including cutting to required size and shade and fixing at corner splays and cambers etc. and joined with neat cement slurry mixed with pigment to match the shade of tile including rubbing & polishing with cost, carriage, taxes of all materials and cost of all labour, T&P required to complete the work etc. complete as per specification and direction of EIC. (Tiles should be of RAK / Kajaria /Somany)in1st Floor
36Providing and fixing 20mm thick Granite stone flooring(sample of Granitestone should be approved by EIC) for stair case trade, riser and similar locations where ever required in horizontal/vertical surfaces of required size of approved shade, colour and texture, with moulding edge etc. laid over 20mm thick bed of cement mortar 1:4 (1 cement: 4 coarse sand) with joints treated with white cement mixed with matching pigment, epoxy touch ups including rubbing, curing, moulding and polishing to give high gloss finish and groove in staircase where required etc. complete as per direction of Engineer-in-charge. In Ground floors and all heights.
37Providing and fixing 20mm thick Granite stone flooring(sample of Granitestone should be approved by EIC) for stair case trade, riser and similar locations where ever required in horizontal/vertical surfaces of required size of approved shade, colour and texture, with moulding edge etc. laid over 20mm thick bed of cement mortar 1:4 (1 cement: 4 coarse sand) with joints treated with white cement mixed with matching pigment, epoxy touch ups including rubbing, curing, moulding and polishing to give high gloss finish and groove in staircase where required etc. complete as per direction of Engineer-in-charge. In 1st floors and all heights.
38Providing 45mm average thick finished flooring with 20mm thick pre-cast PCC chequered tiles (250x250mm) of approved make confirming to IS 1237/1980 made out of red pigment over 25mm thick cement mortar 1:3 mix, joint painted with pigment to match the shade of the tile layed in panels or patterns with necessary leveling coarse including all cost of labour etc. as per direction of Engineer-in-charge.
39Providing and fixing of factory made UPVC 2.5-track Sliding / 3 track window complete with ss mosqueto net, comprising UPVC multi-chambered frame of size 67mm x 54mm with wall thickness of 2.3mm (+-0.2mm) having in-built UPVC roller track on top and UPVC sash of size 64mm x 47mm with wall thickness of 2.3mm (+-0.2mm) duly reinforced with G.I. section 1.2mm (+-0.2mm), wherever required. All corners of frame and sash will be fusion welded. After placing 5mm Clear Annealed glass in the sash, UPVC glazing bead, interlock, EPDM gasket, brush will be provided including hardware, i.e., touch lock and rollers & proper drainage system shall be provided. Window shall be fixed to the wall with 100mm long and 8mm dia. Fasteners and complete in all respect as per direction of Engineer-In-Charge. (Make: Koemmerling / Encraft India Pvt. Ltd / Lingel windows and door technologies pvt ltd. / Torfenster / BUILTIFY).(In all floor)
40Providing and fixing of factory made UPVC openableventilator with provision of Exhust fancomprising UPVC multi-chambered frame of size 67mm x 54mm with wall thickness of 2.3mm (+-0.2mm) having in-built UPVC roller track on top and UPVC sash of size 64mm x 47mm with wall thickness of 2.3mm (+-0.2mm) duly reinforced with G.I. section 1.2mm (+-0.2mm), wherever required. All corners of frame and sash will be fusion welded. After placing 5mm Clear Annealed glass in the sash, UPVC glazing bead, interlock, EPDM gasket, brush will be provided including hardware, i.e., touch lock and rollers & proper drainage system shall be provided. Window shall be fixed to the wall with 100mm long and 8mm dia. Fasteners and complete in all respect as per direction of Engineer-In-Charge. (Make: Koemmerling / Encraft India Pvt. Ltd / Lingel windows and door technologies pvt ltd. / Torfenster / BUILTIFY).(In all floor)
41Providing, fitting and fixing of 32mm thick BWR flush door Partly Glazed both side 1mm anti bectorial laminated as per the specification complete with all materials, inclusive of all hardware material of SS heavy duty hinges, nails, screws, doorknobs, handles, stopper etc. including the cost of all materials, labour and T&P and overheads etc. complete. BWR door of Greenply / Achidply / Mayur & 6 lever lock and high duty door closure of Godrej / Hettich / Dorma / GEZE make) . The rates also includes the cost of 40 x 25mm wooden beading including all hardware fitting including locks and door closure as per direction of EIC.
42Supplying, fitting, fixing 32mm thick FRP door shutter with choukath (90x45) and all type of hard ware fittings to toilets as per approved make shade and design complete as per specifications including cost, conveyance of all materials, cost of all labour, T&P required for the work complete as per direction of EIC.(Door should be of Rajashree / Krishna/ Duroplast / Durasleek make)
43Providing & fabricating Glass Door with 12mm thk. edge polished cleartoughened glass with itching including floor spring & patch fittingsincluding providing and fixing top & bottom pivot & double acting hydraulic floor spring type fixing arrangement and making necessary holes etc. for fixing required door fittings, including cost, coveyance, loading and unloading and of all materials, cost of all labour, sundries, T&P, scaffolding etc. required for the work and complete in all respect as directed by the Engineer in charge as per drawing & directed by Architect. (Dorma/Ozone/Inox )
44Providing seasoned Salwood in frames of required size in doors, windows, clerestory windows and other frames, wrought framed and fixed in position with hold fast lugs or with dash fasteners of required dia & length including cost of all materials, labour, all, transportation, loading & unloading etc. complete as per specification and direction of Engineer -in-charge.
45Providing and fixing double speed Hydraulic Door closer of approved make and model including cost of all materials, labour, all, transportation, loading & unloading etc. complete as per specification and direction of Engineer -in-charge and Architect. (Make- Hettich/ Dorma/ Godrej)
46Providing and fixing bright finished brass 100 mm mortice latch and lock with 6 levers and a pair of lever handles of approved quality with necessary screws etc.complete including cost of all materials, labour, all, transportation, loading & unloading etc. complete as per specification and direction of Engineer -in-charge and Architect.
47Providing partition of full height partly Glazed partition for in otherarea as per drawing with Aluminiumframe 50x25 mmwith 1.5mm thickness intermediates, verticals and horizontal(600mmx600mm) as shown in drawing and shall be fixedto floor, ceiling, walls etc. with suitable size of screws, plugs including making good to damages, with the cost of applying acoat of primer to exposedfaces ofthe timber andfixing6 mm thk .BWR ply both sides of approved make and qualityconfirming to IS 710 over the frameworkwithscrewsatadequate intervals and fixing 1.0 mm thk Laminate both sides on ply (suede finish) withadhesive and 12mm thick glass with 3mm film etching to be fixed with Dorma patch fittings at glazed portion including cost, conveyance, loading, unloading, royalties and taxes of all materials, cost of all labour, sundries, T&P required for the work, complete in all respect as per specification and direction of Engineer-in-charge. (Payment will be made as per height below the false ceiling)(BWR ply of Greenply / Mayur / Archidply)
48Providing & fabricating Glass partition with 12mm thk. edge polished clear toughened glass including itching with patch fittings (Dorma/Ozone/Inox) inclusive necessary accessories, all complete as per drawing & directed by EIC and Architect.
49Providing and installing Aluminum Panel Ceiling of approved make, model and manufacturer as per approved RAL shade, consisting of panels 300 mm wide x 31mm deep Plain panel desired length up to 6Mtr. The panels shall be fabricated 0.70mm thick Roll formed from enameled Corrosion Resistance Aluminum alloy AA 3105 for higher strength and good Roll Forming characteristics with beveled edges, with Anti-microbial 60-micron powder coating activity using Test Based on MOD ISO 22196:2011. Powder coating test result should pass, Pencil hardness ASTM D3363-05, Scratch resistance ISO 1518-1/ SIS 83 91 17, Impact resistance ASTM D2794, Resistance to neutral salt spray ASTM B117, Resistance to humid atmospheres ISO 6270-2, Adhesion ISO 2409, Expected durability of the antimicrobial effect: 25+ years according to an accelerated test.Two sides of Each panel to be raised and piped and stopped / demounting of individual panel. Panel shall be clipped to a baked enameled Aluminum Panel Carrier of 34.5mm wide x 63mm Deep made of 0.95mm thick in standard lengths of 5Mtrs made of Double baked enameled Aluminum Alloy AA 3105 (Al.Mg) Black colour with cut outs to hold the panels in a module of 300mm at a distance of 1.2Mtrs c/c. The panel carrier shall be suspended by means of G.I. suspension rod 4mm diaMtr and galvanized spring clip at a distance of 1.5 Mtr. c/c. all complete as per drawings and as directed by Engineer-in-charge
50Supplying, fitting, fixingM.S. grills and Grill gate as per approved drawing and design given by EIC in all floors made out of standard rolled steel sectionwith corners of frames duly metered and electrically welded with 6 nos. of hold fast Heavy duty hinged for Gates and 4 nos. hold fast for windows. The grills made with MS Square bar/ MD Flat as required in site conditions including one coat of anti-corrosive red oxide paint as per direction of EIC.
51Providing and applying to outside walls with two or more coats ofAnti-Fungal Weather coat water proofing paint having weatherguard and high workablequality over a cost of alkali resistance primer including scaffolding and cleaning the surface before application of approved colour and manufacture as per specification, instruction of Engineer-In-charge at all elevations including all material labour complete at all floors and all heights. (G/F) (Asian paint/ICI/Berger)
52Providing and applying to outside walls with two or more coats ofAnti-Fungal Weather coat water proofing paint having weatherguard and high workablequality over a cost of alkali resistance primer including scaffolding and cleaning the surface before application of approved colour and manufacture as per specification, instruction of Engineer-In-charge at all elevations including all material labour complete at all floors and all heights. (Asian paint/ICI/Berger)in1st Floor
53Finishing surface of walls with Acrylic wall putty (Water based) of approved make and finished smooth and even surface to receive painting including cost of scaffolding staging charges with cost of all materials,cost of all labour, T&P etc. complete as per direction of EIC. (Make SG England/ J.K./Birla) (G/F)
54Finishing surface of walls with Acrylic wall putty (Water based) of approved make and finished smooth and even surface to receive painting including cost of scaffolding staging charges with cost of all materials,cost of all labour, T&P etc. complete as per direction of EIC. (Make SG England/ J.K./Birla)in1st Floor
55Painting two coats with appd. Brand of Plastic emulsion paint of appd. Shade and quality over a coat of approved primer to inside wall including cost of paint, primer, putty, scaffolding, cost ofall labour and materials required for the work etc. comp. (paints of Berger, Nerolac, J&N & Asian ICIBrand is to be used.) (G/F)
56Painting two coats with appd. Brand of Plastic emulsion paint of appd. Shade and quality over a coat of approved primer to inside wall including cost of paint, primer, putty, scaffolding, cost ofall labour and materials required for the work etc. comp. (paints of Berger, Nerolac, J&N & Asian ICIBrand is to be used.)in1st Floor
57Painting two coats with approved brand of synthetic enamel paint of approved shade and quality over a coat of approved primer to wood / iron works including cost of paint, primer, putty, scaffolding, T&P, cost, conveyance, cost of all materials and cost of all labour required for the work etc. complete as per the direction of EIC. (Paints of Burger/Nerolac/J&N /Asian/ ICIBrand is to be used.) (G/F)
58Painting two coats with approved brand of synthetic enamel paint of approved shade and quality over a coat of approved primer to wood / iron works including cost of paint, primer, putty, scaffolding, T&P, cost, conveyance, cost of all materials and cost of all labour required for the work etc. complete as per the direction of EIC. (Paints of Burger/Nerolac/J&N /Asian/ ICIBrand is to be used.)in1st Floor
59Designing, fabricating, testing, protection, installing and fixing in position semi (grid) unitized system of structural glazing (with open joints) for linear as well as curvilinear portions of the building for all heights and all levels, including: (a) Structural analysis & design and preparation of shop drawings for the specified design loads conforming to IS 875 part III (the system must passed the proof test at 1.5 times design wind pressure without any failure), including functional design of the aluminum sections for fixing glazing panels of various thicknesses, aluminium cleats, sleeves and splice plates etc. gaskets, screws, toggles, nuts, bolts, clamps etc., structural and weather silicone sealants, flashings, fire stop (barrier)-cum-smoke seals, microwave cured EPDM gaskets for water tightness, pressure equalisation & drainage and protection against fire hazard including(b) Fabricating and supplying serrated M.S. hot dip galvanised / Aluminium alloy of 6005 T5 brackets of required sizes, sections and profiles etc. to accommodate 3 Dimentional movement for achieving perfect verticality and fixing structural glazing system rigidly to the RCC/ masonry/structural steel framework of building structure using stainless steel anchor fasteners/ bolts, nylon seperator to prevent bimetallic contacts with nuts and washers etc. of stainless steel grade 316, of the required capacity and in required numbers.
60(c) Providing and filling, two part pump filled, structural silicone sealant and one part weather silicone sealant compatible with the structural silicone sealant of required bite size in a clean and controlled factory / work shop environment, including double sided spacer tape, Eachting blocks and backer rod, all of approved grade, brand and manufacture, as per the approved sealant design, within and all around the periMtr for holding glass. (d) Providing and fixing in position flashings of solid aluminium sheet 1 mm thick and of sizes, shapes and profiles, as required as per the site conditions, to seal the gap between the building structure and all its interfaces with curtain glazing to make it watertight(e) Making provision for drainage of moisture/ water that enters the curtain glazing system to make it watertight, by incorporating principles of pressure equalization, providing suitable gutter profiles at bottom (if required), making necessary holes of required sizes and of required numbers etc. complete.
61(e) Making provision for drainage of moisture/ water that enters the curtain glazing system to make it watertight, by incorporating principles of pressure equalization, providing suitable gutter profiles at bottom (if required), making necessary holes of required sizes and of required numbers etc. complete. This item includes cost of all inputs of designing, labour for fabricating and installation of aluminium grid, installation of glazed units, T&P, scaffolding and other incidental charges including wastages etc., enabling temporary structures and services, cranes or cradles etc. as described above and as specified. The item includes the cost of getting all the structural and functional design including shop drawings checked by a structural designer, dully approved by Engineer-in-charge. The item also includes the cost of all mock ups at site, cost of all samples of the individual components for testing in an approved laboratory, field tests on the assembled working structural glazing as specified, cleaning and protection till the handing over of the building for occupation. In the end, the Contractor shall provide a water tight structural glazing having all the performance characteristics etc. all complete as required, as per the Architectural drawings, as per item description, as specified, as per the approved shop drawings and as directed by the Engineer in-Charge.
62Making plinth protection 50mm thick of cement concrete 1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 20mm nominal size) over 75mm bed of dry brick ballast 40mm nominal size well ramed, consolidated and grouted with fine sand and finishing the top smooth including shuttering at the edges, excavation and disposing of surplus earth with a lead of 100m complete as per direction of Engineer-in-charge.
6320mm thick grading plaster with C.M (1:4) mixed with approved water proof to compoundas per manufacturer specificaton (Dr. Fixit) over roof surface including watering and curing etc. Comp. with cost , conveyance, royalty of all materials and cost of all labours, T&P scaffolding required for the work complete as per direction of EIC. (G/F)
64Providing and fixing door signage for Doctor chamber, Farmacy, dispensory,toilets and all other rooms as per design with acrylic sheet including cost of all materials, T&P complete as directed by EIC & Architect.
65Providing, fitting and fixing of Roller blinds with approved make and design to the windows of any approved Fabric and shade of premium quality of reputed make inclusive of cost of structure & fixing as per direction of EIC &Architect. (Make:- MARVEL)
66Supplying and fixing of Curtain of approved design and make in doctor"s chamber and Dispensary including cost of all materials as directed by EIC and Architect. The fabric should be approved before fixing.
67Supplying and fixing of Drapery rod for curtain track of approved design and make in doctor"s chamber including cost of all materials as directed by EIC and Architect.
68Providing waterproofing for Toilet / SukenSlab with Cleaning the inside surface & & Application of two coats of sika Top seal 109 hi @ 2.2 Kg/Sqm & Sika Fab-1 to the battom slab & side wall surface to protect against leakage & seepage finally covered with a cement mortar (1:4). Proper care should be taken to fill the pipe penetration points with sikagard 694 fi (moisture resistant epoxy putty) complete as per manufacture specification anddirection of Engineer-In-Charge.
69Supplying, Fitting, Fixing of stainless steel of 304 grade in hard railing using 50mm dia of 2mm thick circular pipe with balustrade of size 32mm x 32mm x 2mm @ 0.90 mtr C/C and stainless square pipe bracing of size 32mm x 32mm x 2mm in 3 rows in stair case as per approved design and specification, buffing, polishing etc with cost, conveyance of all materials, labour T&P etc. required for the work complete in all respect as per direction of EIC.
7020mm thick grading plaster with C.M (1:4) and admixture of water proofing compound as per manual (Dr Fixit) over roof surface including watering and curing etc. Comp. with cost , conveyance, royalty of all materials and cost of all labours, T&P scaffolding required for the work complete as per direction of EIC. (1st Floor)
71Dismantling of brick or stone masonary in lime or cement mortar under 3 mtr height including stacking the useful materials for reuse & removing the debries from the work site etc complete as per direction of EIC.
72Dismantling & removing doors, window & ventilators including removing frames, hinges, fastening & stacking the same for reuse & removing the debris from the work site etc completed as per direction of EIC.
73Dismantling & removing of old lime or cement plaster from walls including racking out joints 12mm deep & removing the debries from the work site etc completed as per the direction of EIC.
74Dismantiling and removing old tiled caddling from wall including racking out joints 12mm deep. Stacking the useful materials for reuse and removing the debris from the work site etc completed as per the direction of EIC.
75Dismantiling and removing old tiled flooring including removing the base coarse and stacking the useful materials for reuse and removing the debris from the work site etc completed as per the direction of EIC.
76Dismantling and removing 20mm thick Granite stone flooring for stair case trade, riser and similar locations where ever required in horizontal/vertical surfaces and stacking the useful materials for reuse and removing the debris from the work site etc completed as per the direction of EIC.
77Additional labour for shifting loose furniture like table, lab equipments, bed etc completed including cost of all materials, labour, T&P etc as per the direction of EIC.
78Supllying all materials for closing of openning for a temporary porpuse using ISI marked standard types of ply with making good to the damages etc completed including cost of all materials, labour, T&P etc as per the direction of EIC.
79SANITARY AND WATER SUPPLY
80Supplying, installing, fixing, jointing, testing and commissioning of approved make. Chlorinated Polyvinyl Chloride pipes (CPVC) SDR.11 pipes confirming to ASTM standards with necessary fittings for inetrnal toilet water supply upto 50 dia , and above 50mm dia pipe schedule 40withfitting shall be schedule 80 ASTM IPS. The fittings and specials such as tees, elbows,couplers, bends, enlargers etc.,m with CPVC brass threaded combination / transition specials such as male adapters brass threaded female adapters, brass FPT Tee, Brass FPT elbow etc., where connection with metal is to be made including necessary drilling holes, chasing walls and making the same good in cement martor 1:1 restore the same original condition neately as directed by the Engineer in-charge. Joints to be made with CPVC solvent cement up to 50mm dia as per ASTM D-2846 and above 50mm dia primer P-70, and solvent confirming to ASTM F-4931 / 724 All exposed pipe shall be painted with latex paint. (for shafts, basement ceiling ringmain Terrace& PRM).The rate shall include necessary GI supports, GI grip bolts, angle brackets, hangers, supports as with suitable GI U-clamps, bolts, nuts and washers etc., The clamps shall be painted with two coats of enamel (approved) paint over a coat of primer etc., complete. Make:- Supreme/Ashirbad/ASTRAL.
8120 mm dia C-PVC pipe SDR.11GROUNDFLOOR
8225 mm dia C-PVC pipe SDR.11GROUNDFLOOR
8332 mm dia C-PVC pipe SDR.11GROUNDFLOOR
8420 mm dia C-PVC pipe SDR.11FIRST FLOOR
8525 mm dia C-PVC pipe SDR.11 FIRST FLOOR
8650 mm dia C-PVC pipe SDR.11 TERRACEFLOOR
87supplying all materials, labour, T&P and cutting holes through existing brick work including making good the damages in cement mortar (1:4) for taking G.I. Pipes and fittings/ P.V.C. pipes and fittings etc. all complete as per P.H. specification and direction of Engineer-in-charge. 250 mm thick wallGROUNDFLOOR
88supplying all materials, labour, T&P and cutting holes through existing brick work including making good the damages in cement mortar (1:4) for taking G.I. Pipes and fittings/ P.V.C. pipes and fittings etc. all complete as per P.H. specification and direction of Engineer-in-charge. 250 mm thick wall FIRSTFLOOR
89Supplying all materials, labour, T&P and cutting hole in R.C.C floors, roofs, etc upto 19 cm thickfor passing G.I. Pipes / P.V.C pipes and fittings etc and repairing the holes afterinsertion of pipes etc with cement concrete (1:2:4 ) including finishing complete so as to make it leak proof as per direction of theEngineer-in-charge.GROUNDFLOOR
90Supplying all materials, labour, T&P and cutting hole in R.C.C floors, roofs, etc upto 19 cm thickfor passing G.I. Pipes / P.V.C pipes and fittings etc and repairing the holes afterinsertion of pipes etc with cement concrete (1:2:4 ) including finishing complete so as to make it leak proof as per direction of theEngineer-in-charge. FIRST FLOOR
91Supplying all materials, labour, T&P and cutting grooves in pucca floors and walls for taking G.I./P.V.C. pipes and making good the damages as per direction of the E.I.C.
92Supplying, installing, testing and commissioning approved make water level indicator for the Underground Sump and OHT . The quoted rate shall include for necessary wiring in PVC conduit between the control panel, underground sump and overhead tank.(length of cable approx. 100 mts.) (Make:- KENT / MASHAL / KRANTI)
93Excavation of trenches for laying pipes up to 200 mm dia. Including forming bottom surface to required level, refilling the trenches with selected excavated earth around the pipe in layers of 150mm thick, watering, consolidating. Quoted price inclusive of disposing off / Carting away the surplus earth out side the site to a dump yard acceptable local bodies or as directed by the site engineer with a lead of 250mts. etc. complete. All kind of soil
94Supplying, fixing and testing Puddle flanges forinlet, outlet, vent and overflow pipes, fittings with D.I frame and cover to overhead water tank and under ground water tank complete with steps as shown on the drawings etc., complete.OVER HEADWATER TANK 4 nos. M.S manhole frame andcover (medium duty)(weight=15 KN.) with locking facility
95Supplying, fixing OVER HEADWATER TANK10 nos. step ladder(Stainless Steel ladder, Grade - 403)-3 ladder to overhead water tank and under ground water tank complete with steps as shown on the drawings etc., complete.
96Construction of maintanance chamber 760x760x450 with 250mm best quality approved Fly Ash bricks in CM 1:4 over a bed of 100mm thick PCC 1:4:8, internal walls plasteredin "CM 1:3 and external wall with CM 1:3 with sponge finish, benching and channelling in PCC 1:4:8. Supplying and fixing cover of size 600X600mm (weight 110 "Kgs.)The quoted rate shall also include necessary excavation and back filling etc., complete.
97Supply installation and testing commissioning of pressurised float valve with complete accessories as per the engineering in-charge. Terrace & Basement(Make:- ZOLOTO / Leader / Shakti)
98Supply, Installation, Testing and Commissioning of Electrically operated modular type GEYSER for Hot Water facility at each toilet block etc. all complete as per specification and direction of theEngineer-In-Charge. (Model - Erica Vertical Digital Jaquare 25 Ltr)
99Supplying all materials, labour, T&P and fixing standard sized pillar cock of Hindware/Jaquar/Parryware of approved make etc complete including cutting the wall and making good the damages, including cost of all materials complete as per PH specification and direction of Engineering-in-charge. 15mm dia brass pillar cock Jaquar VGP-81001.
100Supplying all materials, labour, T&P and fixing Health Faucet of Hindware/Jaquar/Parryware complete with Chromium plated brass brackets fixed to wooden plugs with Chromium plated brass screws as per specification and direction of theEngineer-In-Charge.15mm dia CP Health Faucet of Jaquar 1.2mtr long, 8MM diaJaquar ALD-573.
101Supplying all materials, labour, T&P and fixing the following vitreous china Wash Down Water Closet (European type W.C. pan) of Hindware/Jaquar/Parryware with integral "p" or "s" trap to the floor with wooden plug and chromium plated pedestal screws including jointing the trap with soil pipe in cement mortar (1:1) fixing plastic seat and cover for wash down water closet with chromium plated brass hinges and rubber buffers including polishing etc all complete as per specification and direction of theEngineer-In-Charge.EWC with "p" / S trap plain Jaquar Continental Cat.No.- CNS-WHT-755SS with seat cover & Flush Cistern Jaquar Cat.No. CNS-WHT -207.
102Supplying all materials, labour T&P and fixing wash basins of Hindware/Jaquar/Parryware with hole for pillar taps with cast iron or M.S.brackets painted white including cutting holes in walls and making good the damages with supply of wooden plugs, screws and cement etc, fixing pedestal for wash basin recessed at the back for the reception of pipes and fittings, fixing PVC waste pipe of 32mm nominal diameter for wash basin including brass check nut complete, fixing pillar taps capstan head screw down high pressure lettered "Hot" and "Cold" with long screws, shanks and back nuts of 15mm dia nominal bore, fixing 15mm dia PVC inlet connection pipe and making connection with pillar cocks and supply mains for wash basin, fixing 32mm dia CP brass waste, etc all complete as per specification and direction of theEngineer-In-Charge.JAQUAR Queens Wash Basin Size - 575x450x195 mm, Cat.No.CNS-WHT-801 Pedestal Cat-no. CNS-WHT-301.
103Supplying all materials, labour, T&P and fixing standard sized Robe Hook ofHindware/Jaquar/Parryware complete with all as per specification and direction of the Engineer in charge. Jaquar Robe hook AQN-7791.
104Supplying all materials, labour, T&P and fixing standard sized two wayBib cock ofHindware/Jaquar/Parrywareof approved make etc complete including cutting the wall and making good the damages, including cost of all materials complete as per PH specification complete as per direction of Er-in-charge. 15mm dia CP Two waybib cock with FlangeJaquar FUS-29041.
105Supplying all materials, labour, T&P and fixing standard sized15mm dia angular Stop cock of Hindware/Jaquar/Parrywareof approved make etc complete including cutting the wall and making good the damages, including cost of all materials complete as per PH specification complete as per direction of Er-in-charge. 15mm dia CP angle stop cock with wall flange Jaquar - FUS-29053.
106Supplying all materials, labour, T&P and fixing standard sized15mm dia conceald stop cock of approved make etc complete including cutting the wall and making good the damages, including cost of all materials complete as per PH specification complete as per direction of Er-in-charge. 20mm dia CP angle stop cock with wall flange Jaquar FUS-29083K
107Supplying all materials, labour, T&P and fixing mirror of superior glass mounted on 6mm thick WPC sheet or plywood sheet and fixed to wooden plugs with CP screws and washers complete as per specification and direction of the Engineer-in-charge. 600mmx450mm size B.E.mirror (Alpina/Golden fish/Belgion)
108Supplying all materials, labour, T&P and fixing standard sizedChromium Plated soap case complete with Chromium Plated brassbrackets fixed to wooden plugs with Chromium Plated brassscrews as per specification and direction of the Engineer in charge. CP soap holder jaquar AQN-7731.
109Supplying all materials, labour, T&P and fixing standard sizedChromium Plated soap dispenser with Chromium Plated brassbrackets fixed to wooden plugs with Chromium Plated brassscrews as per specification and direction of the Engineer in charge. soap dispenserJaguar AKP-35735P
110Supplying all materials, labour, T&P and fixing standard sizedChromium Plated brasstowel ring of complete with Chromium Plated brassbrackets fixed to wooden plugs with Chromium Plated brassscrews as per specification and direction of the Engineer in charge. Towel ring round & round flange.Jaquar AQN-7721.
111Supplying all materials, labour, T&P and fixing standard sizedChromium Plated shower complete with Chromium Plated brassbrackets fixed to wooden plugs with Chromium Plated brassscrews as per specification and direction of the Engineer in charge. 100 mm dia over head shower revolving shower Jaquar -OHS-1989Shower arm of Jaquar SHA 483
112Supplying all materials, labour, T&P and fixing standard sizedChromium Plated long body bib cock complete with Chromium Plated brassbrackets fixed to wooden plugs with Chromium Plated brassscrews as per specification and direction of the Engineer in charge. 15mm dia CPLong body Bib Cock JaquarCON-107KN
113Supplying all materials, labour, T&P and fixing standard sizedChromium Plated brasstowel rail complete with Chromium Plated brassbrackets fixed to wooden plugs with Chromium Plated brassscrews as per specification and direction of the Engineer in charge. Towel rail round & round flange.jaquar ACN-1111BNM
114Fixing of 20mm dia Brass/GM Fulway Valve confirming toIS : 781-1995 of approved makeas per specification complete as per direction of Er-in-charge. 20mm dia brass or gun metal full way valve.(Make- Shakti /Zoloto / Leader)
115Fixing of 25mm dia Brass/GM Fulway Valve confirming toIS : 781-1995 of approved makeas per specification complete as per direction of Er-in-charge. 25mm dia brass or gun metal full way valve.(Make- Shakti / Zoloto / Leader)
116Fixing of 32mm dia Brass/GM Fulway Valve confirming toIS : 781-1995 of approved makeas per specification complete as per direction of Er-in-charge. 32mm dia brass or gun metal full way valve.(Make- Shakti/ Zoloto / Leader)
117Supplying, installing, testing and commissioning butterfly valves with standard lever confirming to IS13039 with necessary connecting fittings like flanges ,nuts and bolts etc., complete. 50mm dia. (Make- Shakti / Zoloto / Leader)
118Supply all materials, labour, T&P and providing fitting & fixing (Aqua guard) pure Chill 80 PSS UV of size 750x570x1350 mm height with water storage capacity 80 liters along with 2 nos of fancets 1 for cold water and 1 for normal water including a flow of 1.5 ltr per minute etc. all complete as per approved drawing, specification and direction of the EIC.
119Providing, fixing, Testing and Commissioning Stainless Steelkitchen sink with drain board (304 grade SS)with CI brackets and stainless steel waste with plug 40mm including painting of fittings and brackets, cutting and making good the walls wherever requiredincluding cutting and making good the wall wherever required complete with all parts and internal fittings of approved make with ISI mark and supplying of necessary brackets, screws etc as per PH specification all complete as per direction of Engineer-in-charge.Nirali Make 510x1040 mm bowl depth 250 mm
120Supplying all materials, labour, T&P and fixing standard sized SINK cock of approved make etc complete including cutting the wall and making good the damages, including cost of all materials complete as per PH specification complete as per direction of Er-in-charge. 15mm dia CP Two waybib cock with FlangeCat. No.: Jaquar FUS-29041
121Supplying all materials, labour, T & P and constructing Gully trap chamber of the following inside size with 8 cm thick R.C.C. precast cover slab in CC (1:2:4) mix using 12mm size h.g. chips, foundation concrete (1:4:8) using 40mm size h.g. metal on bed aound trap , Fly Ash brickwork in CM (1:6) in P&F and inside 12mm thick cement plastering (1:3) finished with a floating coat of neat cement including fixing 100mm x100mm size gully trap, 150mm x150mm C.I gratig etc. all complete as per aproved drawing, specification and direction of Engineer-in-charge.300mmx300mm with RCC cover
122Supplying all materials, labour, T & P and constructing of Inspection chamber of the following inside size with 8 cm thick R.C.C. precast cover slab in CC (1:2:4) mix using 12mm size h.g. chips, foundation concrete (1:4:8) using 40mm size h.g. metal on bed aound trap , Fly Ash brickwork in CM (1:6) in P&F and inside 12mm thick cement plastering (1:3) finished with a floating coat of neat cement including fixing 100mm x100mm size gully trap, 150mm x150mm C.I gratig etc. all complete as per aproved drawing, specification and direction of Engineer-in-charge.Inside size 900mm x800mm x450mm
123Supplying, fixing and testing PVC soil, waste, Rainand vent pipes (SWR) confirming to IS13592 : 2013, type B with rubber ring/Solvent(confirming toIS5382) joint inclusive of allnecessary specials like bends, tees,offsets, door bends, junctions, cowls, etc.,laid underfloor/ fixed on walls,and in pipe shafts etc., complete.The rate shall include necessary GI supports, GI grip bolts, angle brackets, hangers, supports as with suitable GI U-clamps, bolts, nuts and washers etc., The clamps shall be painted with two coats of enamel (approved) paint over a coat of primer etc., complete. Make:- Supreme/Ashirbad/ Oriplast. 75 mm dia .
124Supplying, fixing and testing PVC soil, waste, Rainand vent pipes (SWR) confirming to IS13592 : 2013, type B with rubber ring/Solvent(confirming toIS5382) joint inclusive of allnecessary specials like bends, tees,offsets, door bends, junctions, cowls, etc.,laid underfloor/ fixed on walls,and in pipe shafts etc., complete.The rate shall include necessary GI supports, GI grip bolts, angle brackets, hangers, supports as with suitable GI U-clamps, bolts, nuts and washers etc., The clamps shall be painted with two coats of enamel (approved) paint over a coat of primer etc., complete. Make:- Supreme/Ashirbad/Oriplast. 110 mm dia .
125Supplying, fixing and testing PVC soil, waste, Rainand vent pipes (SWR) confirming to IS13592 : 2013, type B with rubber ring/Solvent(confirming toIS5382) joint inclusive of allnecessary specials like bends, tees,offsets, door bends, junctions, cowls, etc.,laid underfloor/ fixed on walls,and in pipe shafts etc., complete.The rate shall include necessary GI supports, GI grip bolts, angle brackets, hangers, supports as with suitable GI U-clamps, bolts, nuts and washers etc., The clamps shall be painted with two coats of enamel (approved) paint over a coat of primer etc., complete. Make:- Supreme/Ashirbad/Oriplast. 160 mm dia (Rain water drain pipe)
126Supplying all materials, labours,T&p and laying trenches(to level or slope) unplasticized P.V.C pipe conforming to IS4985/2000 of the following out side dia for class-3 (0.60mpa) including jointing with suooly of approved solvent cement by on-heat application method/as per manufacture"s specification,providing and laying in trench cement concrete(1:3:6) with25 mm size hard granite chips in the type C-1 standard bedding and curing e.t.c all complete as per P.H specification and direction of the Engineer in charge 110 mm dia U-PVCpipe with al-round concreteing.Make:- Supreme/Ashirbad/Oriplast.
127Supplying, fixing and testing PVC muilty floortrap 110 mm dia with SS frame and cover 75mm dia outlet fixed on a bed of cement concrete with (Heavy duty type) etc., complete. Make:- Supreme/Ashirbad/Oriplast.
128Providing ,fixing , testing and commissioningof clean outs fabricated from heavy duty PVC pipe for waste and soil lines inside toilets for effective maintenance, laid true to finished floor level with brass chromium plated frame and screw type of cover and key for opening etc., complete 75 mm diaMake:- Supreme/Ashirbad/Oriplast.
129Providing ,fixing , testing and commissioningof clean outs fabricated from heavy duty PVC pipe for waste and soil lines inside toilets for effective maintenance, laid true to finished floor level with brass chromium plated frame and screw type of cover and key for opening etc., complete 110 mm diaMake:- Supreme/Ashirbad/Oriplast.
130Providing ,fixing , testing and commissioningof approved make PVC vent cowl with necessary accessories etc., complete. Make-Supreme/Oriplast/Astral 75 mm dia
131Providing ,fixing , testing and commissioningof approved make PVC vent cowl with necessary accessories etc., complete. Make-Supreme/Oriplast/Astral 110 mm dia
132Providing ,fixing , testing and commissioningof P trap with 100mm dia inlet and 100mm dia outlet fixed on a bed of cement concreteetc., complete.(The frame and grating shall be approved by EIC / Architects)Make:- Supreme/Ashirbad/Oriplast.
133STP & OHT
134Earth work in excavation of foundation trenches in all kinds of soil including moorum, stony earth and earth mixed with boulders (except sheet rocks and boulders requiring for blasting) including dressing and leveling the bed up to the required depth and depositing the excavated materials at places away from the work site with all leads and lifts, T&P shoring and shuttering and dewatering if required etc. comp as directed by EIC.
135Filling foundation trenches and plinth with excavated earth including laying the earth in layers not exceeding 23.5cm (9”) thick ramming and watering with all leads and lifts including cost of all labour, T&P etc. complete as directed by the Engineer-in-charge.
136Supplying offilling sand in foundation and over areas including watering, ramming, consolidating and dressing, labours, tools, taxes etc. all complete as per the specification and direction of Engineer-In-Charge.
137Providing & laying cement concrete of prop. (1:4:8) in foundation bed and floors using 40mm nominal size down graded, screened, washed hard black crusher broken granite metal of approved quality & from approved quarry including laying in the layers not exceeding 100 mm thick, hoisting, lowering, laying, watering and curing etc. complete to the required levels including cost, conveyance, royalty and taxes of all materials, cost of all labour, T&P etc. as required for the work complete and as per direction of Engineer-in-charge.
138R.C.C M-25 grade concrete with20mm & down graded hard crusher broken granite chips including hoisting and laying concrete, watering and curing for three weeks centering and shuttering and finishing the exposed surfaces smooth, providing beads or grooves where necessary including cost, conveyance, royalty of all material, dismantling the centering, shuttering work after the period as specified by the EIC and cost of all labour, T&P required for the work comp. in all respect, excluding cost of reinforcement, binding wires and labour charges for bending, binding and tying the grills. BASE
139R.C.C M-25 grade concrete with20mm & down graded hard crusher broken granite chips including hoisting and laying concrete, watering and curing for three weeks centering and shuttering and finishing the exposed surfaces smooth, providing beads or grooves where necessary including cost, conveyance, royalty of all material, dismantling the centering, shuttering work after the period as specified by the EIC and cost of all labour, T&P required for the work comp. in all respect, excluding cost of reinforcement, binding wires and labour charges for bending, binding and tying the grills. WALL
140R.C.C M-25 grade concrete with20mm & down graded hard crusher broken granite chips including hoisting and laying concrete, watering and curing for three weeks centering and shuttering and finishing the exposed surfaces smooth, providing beads or grooves where necessary including cost, conveyance, royalty of all material, dismantling the centering, shuttering work after the period as specified by the EIC and cost of all labour, T&P required for the work comp. in all respect, excluding cost of reinforcement, binding wires and labour charges for bending, binding and tying the grills.SLAB
141Supplying HYSDbars of appd. Quality size and grade and cutting, bending, binding and tying the grills in proper position as required for the RCC workincluding cost, conveyance of HYSD bars (Fe500 D) and binding wires of 18 to 20 gauge and cost of labour, T&P required to comp. in all respectas directed by the EIC.
14212mm cement plaster on internal smooth side of RCC/brick surfaces after racking out joints or chipped surface with cement mortar of mix 1:4 (1 cement : 4 fine sand) including neat cement punning & necessary scaffolding, curing etc. all complete at all floors and all heights with cost , conveyance, royalty of all materials and cost of all labours, T&P scaffolding required for the work complete as per direction of EIC.
143FURNITURE
144Boards & Laminates: All Cabinets will be made out of HDHMR Board (Green Panelmax / Century Prowood) with inside face of Cabinet hotpressed with 4.0mm Veneer. The Cabinet shutter will also HDHMR board with 4mm specified shade Veneer (Merino / Sunmica / Centuty). The laminates and boards are machine made hot press with Polymersie D3 Adhesive (Fevicol / Akzonobel) for uniform pesting along with Melamine polish. Edge Banding & Glue: All exposed edges mechanically edge banded in German Machine (Homag) with PVC edge banding tape with hot melt glue Adhesive Henkel / Fevicol. Furniture Hardware: The entire furniture are knock down. All H/W fitting will be Hettich / Hafele / Ebco accrodining to the application.Reception Table Transportation installationcomplete etc.including cost , conveyance, royalty of all materials and cost of all labours, T&P scaffolding required for the work complete as per direction of EIC and Architect.
145Boards & Laminates: All Cabinets will be made out of HDHMR Board (Green Panelmax / Century Prowood) with inside face of Cabinet hotpressed with 4.0mm Veneer. The Cabinet shutter will also HDHMR board with 4mm specified shade Veneer (Merino / Sunmica / Centuty). The laminates and boards are machine made hot press with Polymersie D3 Adhesive (Fevicol / Akzonobel) for uniform pesting along with. Edge Banding & Glue: All exposed edges mechanically edge banded in German Machine (Homag) with PVC edge banding tape with hot melt glue Adhesive Henkel / Fevicol. Furniture Hardware: The entire furniture are knock down. All H/W fitting will be Hettich / Hafele / Ebco accrodining to the application.Conference Hall Tablemanufecturing installation etccomplete including cost , conveyance, royalty of all materials and cost of all labours, T&P scaffolding required for the work complete as per direction of EIC and Architect.
146ELECTRIFICATION
147Recessed wiring to light point /fan point/ call bell point/ exhaust fan point /wall fan point with 1.5 sq.mm FRLSH PVC insulated single core multistrand copper conductor of ISI marked in 20 mm dia non-metalic 1.6mm thick PVCconduit with 6 Amp, 250 V clip in type modular switch ISI marked and ceiling rose ISI marked mounted on G.I modular box with face plate & cover of suitable size ,with 1.5 sq.mm FRLSH PVC insulated single core multistrand copper conductor as earth wire including all accessories and connection as per direction ofEIC.(length-5mtr)
148Recessed wiring to secondary light pointlooped from primary light point with 1.5sqmm FRLSH PVC insulated single core multistrand copper conductor of ISI marked with 20mm dia non-metallic PVCconduitwith 1.5sqmm FRLSH PVC insulated single core multistrand copper conductor for running earth including3 plate ISI marked Ceiling rose with all accessories & connection as per direction ofEIC (length-3mtr)
149Recessed wiring to ceiling fan point with 1.5sqmm FRLSH PVC insulated single core multistrand copper conductor of ISI marked with 20mm dia non-metallic PVCconduit with 6Amp 250V Modular Switch,Stepped type Modular Regulator, Base & Cover with 1.5sqmm FRLSH PVC insulated single core multistrand copper conductor for running earth including all accessories & connection as per direction ofEIC.
150Supply & fixing of 6 amp modular socket outletwith6Amp, 250 V clip in type modular switch ISI markedmounted on G.I modular box with face plate & cover of suitable sizeincluding all accessories and connection on same switch board as per direction ofEIC.
151Supply &fixing of 2 nos.of6 amp modular socket outlet with 2 nos6Amp, 250 V clip in typemodular switch ISI markedmounted on single G.I modular box with face plate & cover of suitable sizeincluding all accessories and connection on separate board as per direction ofEIC
152Supply &fixing of 6 pin 16 ampmodular socket outletwith 16Amp, 250 V clip in typemodular switch ISI markedmounted on G.I modular box with face plate & cover of suitable sizeincluding all accessories and connection as per direction ofEIC.
153Supply &fixing of 16 ampmodular socket outletwith 16Amp, 250 V modular switch on separate board including all accessories and connection as per direction ofEIC.
154Recessed wiring to A.Cpoint outletwith 20 amp SPN, industrial type socket outlet, with plug top and metal chained cover in sheet steel enclosure indusrial socket ,20A SP MCBon separate board including all accessories and connection as per direction ofEIC.
155Recessed wiring to submain in 4 x 16 sq.mm FR PVC insulated single core multistrand copper conductor of ISI marked confirming to IS-694/1990 in 40 mm dia non-metalic heavy duty PVC conduit 1.6 mm thick along with 2x 10 sq.mm FR PVC insulated single core multistrand copper conductor as earth wire as equired including all accessories and connection as per direction ofEIC.
156Recessed wiring to submain in 4 x 10 sq.mm FR PVC insulated single core multistrand copper conductor of ISI marked confirming to IS-694/1990 in 32 mm dia non-metalic heavy duty PVC conduit 1.6 mm thick along with 2x 6 sq.mm FR PVC insulated single core multistrand copper conductor as earth wire as equired including all accessories and connection as per direction ofEIC.
157Supply & Recessed wiring to sub main in 4 x 6sq.mmFR PVC insulated single core multistrand copper conductor of ISI marked confirming to IS-694/1990 in 32 mm dia non-metallic heavy duty PVC conduit 1.6 mm thick along with 2 x 4.0 sq.mm FR PVC insulated single core multistrand copper conductor as earth wire as enquiredas per direction ofEIC.
158Supply & Recessed wiring to submain in 2 x 6 sq.mm FR PVC insulated single core multistrand copper conductor of ISI marked confirming to IS-694/1990 in 25 mm dia non-metalic heavy duty PVC conduit 1.6 mm thick along with 1 x 4.0 sq.mm FR PVC insulated single core multistrand copper conductor as earth wire as equiredas per direction ofEIC.
159Supply & Recessed wiring to submain in 2 x 2.5 sq.mm FR PVC insulated single core multistrand copper conductor of ISI marked confirming to IS-694/1990 in 20 mm dia non-metalic heavy duty PVC conduit 1.6 mm thick along with 1 x 1.5 sq.mm FR PVC insulated single core multistrand copper conductor as earth wire as equired.as per direction ofEIC.
160Supply & Recessed wiring to submain in 2 x 1.5 sq.mm FR PVC insulated single core multistrand copper conductor of ISI marked confirming to IS-694/1990 in 20 mm dia non-metalic heavy duty PVC conduit 1.6 mm thick along with 1 x 1.5 sq.mm FR PVC insulated single core multistrand copper conductor as earth wire as equiredas per direction ofEIC.
161Supply and fixing of 4 way (4 + 12) TPN double doorhorizontal type , sheet steel, MCB distribution box, 415 V onrecess, hinged front acrylic cover for the MCB knobs detachable gland plate, interconnections, phosphatized and powder painted including earthing etc. as required as per direction ofEIC.( But with out MCB)
162Supply and fixing of 6 way (4 + 18 ), TPN , MCB DB double doorhorizontal type, sheet steel, MCB distribution box, 415 V onrecess, hinged front acrylic cover for the MCB knobs detachable gland plate, interconnections, phosphatized and powder painted including earthing etc. as required as per direction ofEIC.( But with out MCB)
163Supply and fixing of 8way (4 + 24 ), TPN , MCB DB double doorhorizontal type , sheet steel, MCB distribution box, 415 V onrecess, hinged front acrylic cover for the MCB knobs detachable gland plate, interconnections, phosphatized and powder painted including earthing etc. as required as per direction ofEIC.( But with out MCB)
164Supply and fixing of 4 way SPN , MCB DB double door, sheet steel, MCB distribution box, 415 V on surface / recess, hinged front acrylic cover for the MCB knobs detachable gland plate, interconnections, phosphatized and powder painted including earthing etc. including all accessories and connection as per direction ofEIC. ( But with out MCB/ RCCB/ Isolator)
165Supply and fixing of 8 way SPN , MCB DB double door, sheet steel, MCB distribution box, 415 V on surface / recess, hinged front acrylic cover for the MCB knobs detachable gland plate, interconnections, phosphatized and powder painted including earthing etc.including all accessories and connection as per direction ofEIC. ( But with out MCB/ RCCB/ Isolator)
166Supply and fixing of MCB of 6 amp to 32 amp rating SP MCB , "B" series, 10KA breaking capacityincluding earthing etc.including all accessories and connection as per direction ofEIC.
167Supply and fixing of 25 to 40 amp rating DP RCBO, 30mAincluding earthing etc.including all accessories and connection as per direction ofEIC.
168Supply and fixing of 25 amp rating FP RCBO, 30mA including earthing etc.including all accessories and connection as per direction ofEIC.
169Supply and fixing of 32 amp rating FP RCBO, 30mA including earthing etc.including all accessories and connection as per direction ofEIC.
170Supply and fixing of40 amp rating FP RCBO, 100/300 mA including earthing etc.including all accessories and connection as per direction ofEIC.
171Supply and fixing of 63 amp rating FP RCBO, 100/300 mA including earthing etc.including all accessories and connection as per direction ofEIC.
172Supply of 3.5 C x 185 sq.mm Al (Armoured)XLPE power cable of 1.1 KV grade including all accessories as required as per direction ofEIC.
173Supply of 3.5 C x 95sq.mm Al (Armoured) XLPE power cable of 1.1 KV grade including all accessories and connectionas required as per direction ofEIC.
174Supply of 3.5 C x 50sq.mm Al (Armoured)XLPE power cable of 1.1 KV grade including all accessories as required as per direction ofEIC.
175Supply of 3.5 C x 16 sq.mm Al (Armoured)XLPE power cable of 1.1 KV grade including all accessoriesas required as per direction ofEIC.
176Supply of4 C x 10 sq.mm Al (Armoured) XLPE power cable of 1.1 KV grade including all accessoriesas required as per direction ofEIC.
177Supply of 4C x 6 sq.mm Al (Armoured) XLPE power cable of 1.1 KV grade including all accessories as required as per direction ofEIC.
178Laying of PVC insulated and PVC seathed / XLPE power cable of 1.1 KV grade of size excedding 120 sq.mm but not exceeding 400 sq.mm direct in ground including excavation , sand cushioning, protective covering and refilling the trench etc. as required as per direction ofEIC.
179Laying of PVC insulated and PVC seathed / XLPE power cable of 1.1 KV grade of size not excedding 25sq.mmdirect in ground in the same trench in one tier horizontal formation including excavation , sand cushining protective covering and refilling the trench etc. as required as per direction ofEIC.
180Laying of PVC insulated and PVC seathed / XLPE power cable of 1.1 KV grade of size exceeding 25 sq.mm but not exceeding 120 sq.mm in ground including excavation, protection etc. refilling the trench as required as perdirection ofEIC.
181Laying and fixing of PVC insulated and PVC seathed / XLPE power cable of 1.1 KV grade of size not exceeding 25 sq.mm on surface as required as per direction ofEIC.
182Laying and fixing of PVC insulated and PVC seathed / XLPE power cable of 1.1 KV grade of size exceeding 25 sq.mm but not exceeding 120 sq.mm on surface as required as per direction ofEIC.
183Laying and fixing of PVC insulated and PVC seathed / XLPE power cable of 1.1 KV grade of size exceeding 120 sq.mm but not exceeding 400 sq.mm on surface as required as per direction ofEIC.
184Supply and making end termination with brass double compression gland and aluminum lugs for 3.5 C x 185 sq.mm Alof PVC insulated and PVC sheathed / XLPE aluminum cable of 1.1 KV as requiredas per direction ofEIC.
185Supply and making end termination with brass double compression gland and aluminum lugs for 3.5 C x 95sq.mm Alof PVC insulated and PVC sheathed / XLPE aluminum cable of 1.1 KV as requiredas per direction ofEIC.
186Supply and making end termination with brass double compression gland and aluminum lugs for 3.5 C x 50 sq.mm Alof PVC insulated and PVC sheathed / XLPE aluminum cable of 1.1 KV as requiredas per direction ofEIC.
187Supply and making end termination with brass double compression gland and aluminum lugs for 4 C x 16 sq.mm Alof PVC insulated and PVC sheathed / XLPE aluminum cable of 1.1 KV as requiredas per direction ofEIC.
188Supply and making end termination with brass double compression gland and aluminum lugs for 4 C x 10 sq.mm Alof PVC insulated and PVC sheathed / XLPE aluminum cable of 1.1 KV as requiredas per direction ofEIC.
189Supply and making end termination with brass double compression gland and aluminum lugs for 4 C x 6sq.mm Alof PVC insulated and PVC sheathed / XLPE aluminum cable of 1.1 KV as requiredas per direction ofEIC.
190Supply, installation,testing & commissioning of floor mounting MAIN PANEL with front operated front access extensible type cubicle panel totally enclosed, dust and vermin proof with IP-42 /55 protection with hinged and lockabale doors.CRCA sheets including Busbars,interconnections,tinned copper crimping lugs, bonding to earth and painting suitable for use at 415 V, 3phase 4 wire 50 Hz system, and to withstand a fault level of 36KA symmetrical for 1 sec at 415 V complete as per specifications incoming: 400A 4P C/O Switch -1 No &400A 4P MCCB (36kA) -1 No,outgoing: 100A 4P MCCB (36kA)- 3 No, 63A 4P MCB- 6 Nos, 40A 4P MCB- 3 Nos, 32A 4P MCB- 2 Nos, 32A 2P MCB-6 Nos including earthing etc. as required as per direction ofEIC.
191Supply, installation,testing & commissioning of floor mounting UPS PANEL with front operated front access extensible type cubicle panel totally enclosed, dust and vermin proof with IP-42 /55 protection with hinged and lockabale doors.CRCA sheets including Busbars,interconnections,tinned copper crimping lugs, bonding to earth and painting suitable for use at 415 V, 3phase 4 wire 50 Hz system, and to withstand a fault level of 36KA symmetrical for 1 sec at 415 V complete as per specifications incoming: 100A 4P MCCB (36kA) -1 No,outgoing:40A 4P MCB- 4 Nos, 32A 2P MCB-6 Nos including earthing etc. as required as per direction ofEIC.
192Supply, installation,testing & commissioning of floor mountingPANEL with front operated front access extensible type cubicle panel totally enclosed, dust and vermin proof with IP-42 /55 protection with hinged and lockabale doors.CRCA sheets including Busbars,interconnections,tinned copper crimping lugs, bonding to earth and painting suitable for use at 415 V, 3phase 4 wire 50 Hz system, and to withstand a fault level of 36KA symmetrical for 1 sec at 415 V complete as per specifications incoming: 63A 4P MCCB (36kA) -1 No,outgoing:40A 4P MCB- 3 Nos, 32A 2P MCB-12 Nos including earthing etc. as required as per direction ofEIC.
193Supply, installation,testing & commissioning of Automatic Power Factor Correction Panel of 80 kVAr capacity suitable for 440 Volts 3 phase 50 Hz & having APP type heavy duty 525v , self fusing, low loss, self healing, resin bonded without oil, three phase delta connected capacitors (confirming to IS:2834 IS:13346 IEC-831/1-2, & IEC-439(1-2), housed in alluminum cans & having current limiting contacts circuit to suppress switching in rush current & having 12 step microprocessor based APFC relay with digital displaycontrolling capacitors of rating5,10 kVAr for improvement upto 0.99/unity P.F. of the system & provided with 200 Amps 4P MCCB (50kA) and set of 200/5 CTs with Digital Ammeter and selector switch, capacitor duty contactors with 3Pole MCCB of suitable rating , auto manual selector switch, ON/OFF indicating lamp and push button, 1 No 400/5 CT in the the main panel, including interconnection and control wiring with copper cable etc. complete with 14% detuned reactor as required.5kVAr shall be of fixed typeas required as per direction ofEIC.
194Supply and fixing of copper earth plate 600 mm x 600mm x 3.15 mm thick ISI marked including accessories and providing masonary with cover plate having locking arrangement and watering pipe etc (But wih out charcoal and salt)including all accessories and connection as per direction ofEIC.
195Supply of extra salt and charcoal for G.I or copper plate earth as requiredthick ISI markedincluding all accessories as per direction ofEIC.
196Supply and fixing of8 SWG (4 mm) dia copper wire on surface or in recess for loop earthing including all accessories and connection as per direction ofEIC.
197Supply and fixingof 25x6 GI flat for earthing including all accessories and connection as per direction ofEIC.
198Supply and fixing of 1 Mtr , 12mm G.I. lighting arrestor Spike including all accessories and connection as per direction ofEIC.
199Supply and fixing of 3 Phase Surge Protection Devices including all accessories and connection as per direction ofEIC.
200Supply, Installation,and Commissioning of pre-wired Surface mounted indoor type 18WLEDLuminaire complete with all accessories and lamp etc.including connection with 1.5 sq.mm FR PVC insulated single core multistrand copper conductor and earthing including all accessories and connection as per direction ofEIC.
201Supply, Installation,and Commissioning of Surface mounted indoor type 12W ROUND LED luminaires complete with all accessories,connection as per direction ofEIC.
202Supply, Installation,and Commissioning ofSurface mounted indoor type 10W BULK HEADLED Luminaire complete with all accessories,connection as per direction ofEIC.
203Supply, Installation,and Commissioning of10W MIRRORLED Luminairecomplete with all accessories,connection as per direction ofEIC.
204Supply, Installation,and Commissioning ofRecessed mounted indoor type 15W ROUND LED Luminaire complete with all accessories,connection as per direction ofEIC.
205Supply, Installation,and Commissioning ofrecess mounted indoor type 36W 2"x2" SQUARE LED Luminaire complete with all accessories,connection as per direction ofEIC.
206Supply, Installation,and Commissioning ofSurface mounted indoor type 18W cylindricalLED Luminaire complete with all accessories,connection as per direction ofEIC.
207Supply, Installation,and Commissioning ofCall Bell / Buzzer ISI marked suitable for DC /AC single phase 230 volts complete as required with all accessories,connection as per direction ofEIC.
208Supply, Installation, and Commissioning of BLDC ceiling fan 1200mm sweep, including wiring the down rods of standard length (upto 30 cm) with 1.5 sq.mm FR PVC insulated single core multiatrand copper conductor etc complete as required with all accessories,connection as per direction ofEIC.
209Supply, Installation, and Commissioning of heavy duty exhaust fan of 300 mm sweep 900 rpm Energy efficient type in the existing opening, including making the hole to suit the size of the above fan, making good the damage complete, connection, etcas required. complete as required with all accessories,connection as per direction ofEIC.
210Supply, Installation, and commissioning of heavy duty exhaust fan of 150 mm sweep 900 rpm in the existing opening, including making the hole to suit the size of the above fan, making good the damage complete as required with all accessories,connection as per direction ofEIC.
211Supply & fixing extra down rod of 50 cm length G.I. pipe 20 mm dia heavy gauge including painting etc as required . ( more than 5 cm lenght shall be rounded to the nearest 10 cm and 5 cm or less shall be ignored complete as required with all accessories,connection as per direction ofEIC.
212Supply and fixing ofmodular electronics step type fan regulator complete as required with all accessories,connection as per direction ofEIC.
213Supply & Recessed wiring to telephone pointwithclip in type modular telephone socket (RJ 11) ISI markedmounted on G.I modular box with face plate & cover of suitable size , including all accesories and connection as per direction ofEIC.
214Supply & Recessed wiring to LAN pointwithclip in type modular lan socket (RJ45) ISI markedmounted on G.I modular box with face plate & cover of suitable size , including all accesories and connection as per direction ofEIC.
215Supply , installation ,testing & commissioning of 2 MP Dome Camera, 30 fps, H.265/264, 1920 x 1080, 20 Mtr, Smart IR LED 6, WDR Enhanced, IP 67, IK 10, -30° ~ 60° Cincluding all accesories and connection as per direction ofEIC.
216Supply , installation ,testing & commissioning of 2 MP PTZ Camera, 25X optical zoom100 Mtr, Smart IR LED 6, WDR Enhanced, IP 67, IK 10, -30° ~ 60° Cincluding all accesories and connection as per direction ofEIC.
217Supply , installation , testing & commissioning of 4 TB Hard Disk Enterprises Seriesincluding all accesoriesas per direction ofEIC.
218Supply , installation , testing & commissioning of 8 CH Nvr, H.265 , 200 MBPS, 1 Sata Port,including all accesories and connection as per direction ofEIC.
219Supply , installation , testing & commissioning of 24 port giga MbpsSwitch with 2 Giga SFP Uplink Portsincluding all accesories and connection as per direction ofEIC.
220Supply,delivery, installation,testing & commissioning of indoor wall mounted type telephone distributionMDF box suitable for 10 pair telephone cable termination. made out of 1.6mm thick CR sheet steel duly primered & painted with enamel paint having hinged front door, testing facility having provision for cable / conduit entry complete as per direction of EIC
221Supply,delivery, installation,testing & commissioning of indoor wall mounted type telephone distributionMDF box suitable for 20 pair telephone cable termination. made out of 1.6mm thick CR sheet steel duly primered & painted with enamel paint having hinged front door, testing facility having provision for cable / conduit entry complete as per direction of EIC
222Supply and fixing of push button hand sets complete as per direction of EIC
223Supply, delivery, laying and testing of10 pair of PVC insulated jelly filled armoured telephone cable laid on surface of wall/ column/ roof/ partitions of the building or inside prelaid conduit/ hume pipes/ GI pipes/ soil digging, as the case may be, complete as required and as per direction of EIC
224Supply, delivery, laying and testing of 20 pair of PVC insulated jelly filled armoured telephone cable laid on surface of wall/ column/ roof/ partitions of the building or inside prelaid conduit/ hume pipes/ GI pipes/ soil digging, as the case may be, complete as required and as per direction of EIC
225Supply, delivery, installation,testing & commissioning of Advanced IP EPABX System with 6 Co(P&T) line and 32Extensions and Digital KTS, 16line card -2Nos, Expansion Unit , Tie card & all accessories complete as required as per direction of EIC
226Supply, Delivering,Installing, Testing & commissioning of CAT - 624 port patch max patch panel suitable for rack mounting including all accessories complete as required as per direction of EIC
227Supply, Delivering,Installing, Testing & commissioning of 24 port switch CISCO WS-C2960-24-S distribution data managed switch suitable for rack mounting including all accessories complete as required as per direction of EIC.
228Supply, Delivering,Installing, Testing & commissioning ofTransreceiver for OFC to Ethernet converter including all accessories complete as required as per direction of EIC.
229Supply & Installation of 1 mtr longCat-6 patch cord including all accessories complete as required as per direction of EIC
230Supply & Installation of 2 mtrlongCat-6 patch cord including all accessories complete as required as per direction of EIC.
231Supply & Fixing of 9U Rack single section glass door with cable manager, fan & AC Power Distribution Unit. including all accessories complete as required as per direction of EIC
232Supply & Fixing of 6U Rack single section glass door with cable manager, fan & AC Power Distribution Unit. including all accessories complete as required as per direction of EIC.
233Supply and fixing of 16 / 18 SWG metal box of 200 mm x 150 mm x 60 mm deepon surface / recess with suitable size of phenolic laminated sheet cover in front including cutting the wall and making good the same including all accessories complete as required as per direction of EIC.
234Supplyand fixing of 25mm PVC conduit along with accessories in Supply & Recessed wiring including cutting the wall and making good the sameincluding all accessories complete as required as per direction of EIC.
235Supply and drawing one pair, 0.5 sq.mm FR PVC insulated coper conductor, unarmoured telephone cable in existing surface / Supply & RecessedPVC conduitincluding all accessories complete as required as per direction of EIC.
236Supply and drawing of TV cable RG-6 grade, 0.7 mm solid copper conductor PE insulated shielded with fine tined copper braid & protected with FR PVC sheath inexisting surface /RecessedPVC conduitincluding all accessories complete as required as per direction of EIC.
237Supply and drawing UTP 4 pairLAN cat-6 cable in the existing surface / Supply & Recessed PVC conduit including all accessories complete as required as per direction of EIC
238Supply and fixing of Energy efficient 25W Street light LED luminaire with high pressure die cast aluminium housing with pure polyester powder coated dark grey Housing with high purity PMMA lense,Toughened glass with silicon gaskets for IP66 protection including all accessoriesas required as per direction of EIC.
239Supply and fixing of 32 mm dia X 2.00 metres long G.I. pipe (medium class) bracket for mounting of fluorescent / HPMV / HPSV street light fitting on pole including bending the pipe to the required shape, 2 nos 40 mm X 3 mm flat iron clamps with nuts, bolts and washer, painting the flat iron with primer and finish paint etc. including all accessoriesas required as per direction of EIC.
240Supply and fixing of 16SWG metal box of 200 mm x 150 mm x 60 mm deepon surface / recess with suitable size of phenolic laminated sheet cover in front including cutting the wall and making good the sameincluding all accessoriesas required as per direction of EIC
241Supply and installation of Rubber Mats 12mm thick of size 2000mm x 1000mm x 12 mm thick Electrical tested with test certificateincluding all accessoriesas required as per direction of EIC.
242Supply and fixing of fire buckets with angular fabricated stand to fix 4 buckets in each stand for Electrical fire protection as per standards of Electrical Inspectorate.
243Supply and fixing of shock treatement charts duly laminated along with separate colour single line diagram laminated, to be fixed in Electrical control panel roomincluding all accessoriesas required as per direction of EIC.
244Supply and handing over 11KV Tested Rubber hand gloves to be used on LT supply with Test certificateas required as per direction of EIC.
245Supply and fixing of first aid box with medicines complete with medicine with three years expiry date to be fixed in Electrical control panel roomincluding all accessoriesas required as per direction of EIC.
Disclaimer :
We takes all possible care for accurate & authentic tender information, however Users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender.
Tell us about your Product / Services,
We will Find Tenders for you

Copyright © 2024 · All Rights Reserved. Terms of Usage | Privacy Policy

For Tender Information Services Visit : TenderDetail