Petroleum and Natural Gas Boards / Undertakings / PSU Closing in 0 days TDR #39031140

Tender For Renovation And Extension Of Canteen In Technical Building At Gail Vijaipur

Issued by Boards / Undertakings / PSU · vijaipur, Madhya Pradesh
Tender Value
Ref. Documents
Estimated cost
Bid Submission
31 Aug 2023
0 days left
EMD
63730
Bank guarantee accepted
Document Fee
Ref. Documents
Non-refundable
Tender Type
Online

Tender Overview

Competition Type
NCB
Bidding Type
Tender
Location / State
vijaipur → Madhya Pradesh
EMD Exemption
Not Available
Quantity
Not Available

Project Description

Tender For Renovation And Extension Of Canteen In Technical Building At Gail Vijaipur

BOQ

Name of Work: RENOVATION AND EXTENSION OF CANTEEN IN TECHNICAL BUILDING AT GAIL VIJAIPUR.MPER AND ASSOCIATED SYSTEMS INSTALLED IN LEAN GAS COMPRESSOR (LGC) AT C2C3 RECOVERY PLANT GAIL, VIJAIPUR.
Sl. No. Item Description
1CIVIL WORKS
2Earth work in excavation : Earth work in excavation in foundation, trenches or drainsfor any depth including dressing of sides and ramming of bottoms, including getting out the excavated soil and disposal of surplus excavated soil within GAIL premises or as directed by EIC, including all leads & lifts & depth. Earth/ disposed soil to be leveled & neatly dressed for all kind of soil including soft rock
3Excavation of trenches : Excavating trenches of required width for pipes, cables, etc including excavation for sockets, and dressing of sides, ramming of bottoms, depth upto 1.5 m, including getting out the excavated soil, and then returning the soil as required, in layers not exceeding 20 cm in depth, including consolidating each deposited layer by ramming, watering, etc. and disposing of surplus excavated soil as directed, within a lead of 50 m :All kinds of soil. Pipes, cables etc. exceeding 80 mm dia. but not exceeding 300 mm dia
4Backfiling : Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift upto 1.5 m.
5Carriage of earth : Carriage of Earth by mechanical transport including loading, unloading and Stacking including royalty & carriage up to 5 KMcomplete.
6S&F in plinth : Supplying and filling in plinth with sand under floors, including watering, ramming, consolidating and dressing complete.
7Chemical Emulsion : Supplying chemical emulsion in sealed containers including delivery as specified.Chlorpyriphos/ Lindane emulsifiable concentrate of 20%
8Anti-termite treatment : Diluting and injecting chemical emulsion for POST-CONSTRUCTIONAL anti-termite treatment (excluding the cost of chemical emulsion) :Treatment of soil under existing floors using chemical emulsion @ one litre per hole, 300 mm apart including drilling 12 mm diameter holes and plugging with cement mortar 1 :2 (1 cement : 2 Coarse sand) to match the existing floor: With Chlorpyriphos/Lindane E.C. 20% with 1% concentration
9PCC : Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level :1:4:8 (1 Cement : 4 coarse sand (zone-III) derived from natural sources : 8 graded stone aggregate 40 mm nominal size derived from natural sources)
10Centering & Shuttering : Centering and shuttering including strutting, propping etc. and removal of form work for :Foundations, footings, bases for columns
11DPC : Providing and laying damp-proof course 50mm thick with cement concrete 1:2:4 (1 cement : 2 coarse sand(zone-III) : 4 graded stone aggregate 20mm nominal size).
12Water proofing material : Extra for providing and mixing water proofing material in cement concrete work in doses by weight of cement (50kg per bag ) as per manufacturer\"s specification.
13Residual petroleum bitumen : Providing & applying a coat of residual petroleum bitumen of grade of VG-10 of approved quality using 1.7kg per square metre on damp proof course after cleaning the surface with brushes and finally with apiece of cloth lightly soaked in kerosene oil.
14Centering & Shuttering : Centering and shuttering including strutting, propping etc and removal of form for: Lintels, beams, plinth beams, girders, bressumers and cantilever, foundations, footings, bases of columnsetc.for mass concrete etc., suspended floors, roofs, landings, balconies, shelves (cast in situ), stairs and access platform, walls (any thickness including attached pilasters, columns Pillars, Piers, Abutments, Posts and Struts etc.
15Reinforcement : Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete upto plinth level & above plinth level upto floor V level. Thermo-Mechanically Treated bars of grade Fe-500D or more.
16Plaster drip groove : Add for plaster drip course/ groove in plastered surface or moulding to R.C.C. projections.
17RCC upto plinth level : Providing and laying in position specified grade of reinforced cement concrete, excluding the cost of centering, shuttering, finishing and reinforcement - All work up to plinth level :1:1.5:3 (1 cement : 1.5 coarse sand (zone-III) derived from naturalsources : 3 graded stone aggregate 20 mm nominal size de rived from natural sources)
18RCC above plinth level : Reinforced cement concrete work in beams, suspended floors, roofs having slope up to 15° landings, balconies, shelves, chajjas, lintels, bands, plain window sills, staircases and spiral stair cases, walls (any thickness), including attached pilasters, buttresses, plinth and string courses, fillets, columns, pillars, piers, abutments, posts and struts etc. above plinth level up to floor five level, excluding cost of centering, shuttering, finishing and reinforcement : 1:1.5:3 (1 cement : 1.5 coarse sand(zone-III) derived from natural sources : 3 graded stone aggregate 20 mm nominal size derived from natural sources)
19Brickwork in foundation & plinth : Brick work with common burnt clay F.P.S. (non modular) bricks of class designation 5 in foundation and plinth in:Cement mortar 1:6 (1 cement : 6 coarse sand)
20Brickwork from plinth to floor V : Brick work with common burnt clay F.P.S. (non modular) bricks of class designation 5 in superstructure above plinth level up to floor V level in all shapes and sizes in :Cement mortar 1:6 (1 cement : 6 coarse sand)
21Half brickwork : Half brick masonry with common burnt clay F.P.S. (non modular) bricks of class designation 5 in superstructure above plinth level up to floor V level.Cement mortar 1:4 (1 cement :4 coarse sand)
22MS bars for brick work : Extra for providing and placing in position 2 Nos 6mm dia. M.S. bars at every third course of half brick masonry
23Brick edging : Brick edging 7cm wide 11.4 cm deep to plinth protection with common burnt clay F.P.S. (non modular) bricks of class designation 5 including grouting with cement mortar 1:4 (1 cement : 4 fine sand).
2418mm thick gang saw cut : Providing and fixing 18mm thick gang saw cut ( premoulded and prepolished) machine cut for kitchen platforms, vanity counters, window sills , facias and similar locations of required size of approved shade, colour and texture laid over 20mm thick base cement mortar 1:4 (1 cement : 4 coarse sand) with joints treated with white cement, mixed with matching pigment, epoxy touch ups, including rubbing, curing, moulding and polishing to edge to give high gloss finish etc. complete at all levels. Granite stone slab colour black, Cherry/Ruby red. Area of slab over 0.50 M2.( For Counter)
25Fixing marble / granite stone : MARBLE & GRANITE WORKSExtra for fixing marble / granite stone over and above corresponding basic item, in facia and drops of width upto 150mm with epoxy resin baesd adhesive including cleaning etc. complete.
26Opening for washbasin/sink : MARBLE & GRANITE WORKSExtra for providing opening of required size & shape for wash basins/ kitchen sink in kitchen platform, vanity counters and similar location in marble /Granite/Stone work including necessary holes for pillar taps etc. including rubbing and polishing of cut edge etc. complete.
27P&F stone slab : MARBLE & GRANITE WORKSProviding and fixing stone slab with table rubbed, edges rounded and polished, of required size of 18mm thick , fixed inpartitions by cutting a chase of appropriate width with chase cutter and embedding the stone in the chase with epoxy grout or with cementconcrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 6 mm nominal size) as per direction of Engineer-in-charge and finished smooth. Granite Stone of approved shade.
28P&F ceramic glazed wall tiles : MARBLE & GRANITE WORKSProviding and fixing Ist quality ceramic glazed wall tiles conforming to IS: 15622 (thickness to be specified by the manufacturer), of approved make, in all colours, shades except burgundy, bottle green, black of any size as approved by Engineerin- Charge, in skirting, risers of steps and dados, over 12 mm thick bed of cement mortar 1:3 (1 cement : 3 coarse sand) and jointing with grey cement slurry @ 3.3kg per M2, including pointing in white cement mixed with pigment of matching shade complete.
29Wood work in frames : Providing wood work in frames of doors, windows, clerestory windows and other frames, wrought framed and fixed in position with hold fast lugs or with dashfasteners of required dia & length (hold fast lugs or dash fastener shall be paid for separately).Second class teak wood
30Flush door shutter : Providing and fixing ISI marked flush door shutters conforming to IS : 2202 (Part I) non-decorative type, core of block board construction with frame of 1st class hard wood and well matched commercial 3 ply veneering with vertical grains or cross bands and face veneers on both faces of shutters:35 mm thick including ISI marked Stainless Steel butt hinges with necessary screws
31Lipping : WOOD & PVC WORKExtra for providing lipping with 2nd class teak wood battens 25 mm minimum depth on all edges of flush door shutters (over all area of door shutter to be measured).
32Wooden moulded beading : Providing and fixing wooden moulded beading to door and window frames with iron screws, plugs and priming coat on unexposed surface etc. complete : 2nd class teak wood50x12 mm
33MS grills : Providing and fixing M.S. grills of required pattern in frames of windows etc. with M.S. flats, square or round bars etc. including priming coat with approved steel primer all complete.Fixed to steel windows by welding
3440*5 flat iron : Providing 40x5 mm flat iron hold fast 40 cm long including fixing to frame with 10 mm diameter bolts, nuts and wooden plugs and embedding in cement concrete block 30x10x15cm 1:3:6 mix (1 cement : 3 coarse sand : 6 graded stone aggregate 20mm nominal size).
35P&F decorative high pressure laminated sheet : Providing & Fixing decorative high pressure laminated sheet of plain / wood grain in gloss / matt/ suede finish with high density protective surface layer and reverse side of adhesive bonding quality conforming to IS : 2046 Type S, including cost of adhesive of approved quality.1.0 mm thick
36Door closer : Providing and fixing approved brand and manufacture of Rack and pinion door closer with std. arm and with two independent closing valves and latching speed adjustable by arm. Silver finish. Approved Make : dormakaba/ Hafele / GEZE with necessary accessories and screws etc. complete in all respects as per manufacturespecificatios & as directed by Engineer-in-charge.
37Wall mounted door stop : Providing and fixing approved brand and manufacture of wall mounted door stop dome with 60mm length with fixing accessories Approved Make : dormakaba/ Hafele / GEZE with necessary accessories and screws etc. complete in all respects as per manufacturespecificatios & as directed by Engineer-in-charge.
38Lever handle : Providing and fixing approved brand and manufacture of Pure 8100 Type 3 Package with Pair of Pure 8100 Design Lever Handle on Roses & escutcheons. Including 271a Sash lock with 72mm CTC, 55mm Backset 20mm Square forend. EPC 60mm length oneside thumb turn otherside coin release operation Approved Make : dormakaba/ Hafele / GEZE with necessary accessories and screws etc. complete in all respects as per manufacture ofrs\" specificatios & as directed by Engineer-in-charge.
39SS tower bolt-300mm long : Providing and fixing approved brand and manufacture of Stainless SteelTower bolt 300 mm long with 10 mm dia along with necessary accessories and screws etc. complete in all respects as per manufacturespecificatios & as directed by Engineer-in-charge.
40SS tower bolt-150mm long : Providing and fixing approved brand and manufacture of Stainless Steel Tower bolt 150 mm long with 10 mm dia along with necessary accessories and screws etc. complete in all respects as per manufacturespecificatios & as directed by Engineer-in-charge.
41SS door buffer : Providing and fixing approved brand and manufacture of Stainless Steel Door Buffer wall mounted 22 mm dia,75 mm long along with necessary accessories andscrews etc. complete in all respects as per manufacture specificatios & as directed by Engineer-in-charge.
42SS Handle : Providing and fixing approved brand and manufacture of Stainless Steel Handle 125 mm long with necessary accessories andscrews etc. complete in all respects as per manufacture specificatios & as directed by Engineer-in-charge.
43SS sliding tower bolt : Providing and fixing approved brand and manufacture of Stainless Steel Sliding Tower Bolt 300x16 mm long with necessary accessories andscrews etc. complete in all respects as per manufacturespecificatios & as directed by Engineer-in-charge.
44Fly proof stainless steel : Providing and fixing fly proof stainless steel grade 304 wire gauge, to windows, Doors and clerestory windows using wire gauge with average width of aperture 1.4 mm in both directions with wire of dia. 0.50 mm all complete. With aluminium Snap beading.
45Steel roller for uPVC : Providing and fixing steel roller for uPVC / aluminium sliding window with necessary screws etc. complete.
46Steel crescent lock for uPVC : Providing and fixing steel (white powder coated) crescent lock for uPVC / aluminium sliding window/ door with necessary screws etc. complete.
47Steel work in built up tubular trusses : Steel work in built up tubular (round, square or rectangular hollow tubes etc.) trusses etc., including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer, including welding and bolted with special shaped washers etc. complete.Hot finished welded type tubes
48Nuts and washers : Providing and fixing bolts including nuts and washers complete.
49Steel work im built up sections : Steel work welded in built up sections/ framed work including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer using structural steel etc. as requiredIn gratings, frames, guard bar, ladder, railings, brackets, gates and similar works.
50Carbon steel galvanised fastener : Providing and fixing carbon steel galvanised ( minimum coating 5 micron) dash fastener of 10 mm dia double threaded 6.8 grade (yield strength 480 N/mm2), counter sunk head, comprising of 10 mm dia polyamidePA 6 grade sleeve, including drilling of hole in frame , concrete/ masonry, etc. as per direction of Engineer-in-charge.10 x 60 mm
51SS railing made of Hollow tube : Providing and fixing stainless steel ( Grade 304) railing made of Hollow tubes, channels, plates etc., including welding, grinding, buffing, polishing and making curvature (wherever required) and fitting the same with necessary stainless steel nuts and bolts complete, i/c fixing the railing with necessary accessories & stainless steel dash fasteners , stainless steel bolts etc., of required size, on the top of the floor or the side of waist slab with suitable arrangement as per approval of Engineer-incharge, (for payment purpose only weight of stainless steel members shall be considered excluding fixing accessories such as nuts, bolts, fasteners etc.).
52Glazed ceramic floor tiles : Providing and laying rectified Glazed Ceramic floor tiles of size 300x300 mm or more (thickness to be specified by the manufacturer), of 1st quality conforming to IS : 15622, of approved make, in all colours, shades, except White, Ivory, Grey, Fume Red Brown, laid on 20 mm thick Cement Mortar 1:4 (1 Cement : 4 Coarse sand), jointing with grey cement slurry @ 3.3 kg/ M2 including pointing the joints with white cement and matching pigments etc., complete.
53Vitrified floor tiles : Providing and laying vitrified floor tiles in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS: 15622, of approved make, in all colours and shades, laid on 20mm thick cement mortar 1:4 (1 cement : 4 coarse sand), jointing with grey cement slurry @ 3.3 kg/ M2 including grouting the joints with white cement and matching pigments etc., complete. Size of Tile 600 x 600 mm
54Vitrified tiles in skirting, riser of steps etc : Providing and laying Vitrified tiles in different sizes (thickness to be specified by manufacturer), with water absorption less than 0.08 % and conforming to I.S. 15622, of approved make, in all colours & shade, inskirting, riser of steps, over 12 mm thick bed of cement mortar 1:3 (1 cement: 3 coarse sand), jointing with grey cement slurry @ 3.3 kg/ M2 including grouting the joint with white cement & matching pigments etc. complete.Size of Tile 600 x 600 mm
55False ceiling : Providing and fixing false ceiling at all height including providing and fixing of frame work made of special sections, power pressed from M.S. sheets and galvanized with zinc coating of 120 gms/M2 (both side inclusive) as per IS : 277 and consisting of angle cleats of size 25 mm wide x 1.6 mm thick with flanges of 27 mm and 37mm, at 1200 mm centre to centre, one flange fixed to the ceiling with dash fastener 12.5 mm dia x 50mm long with 6mm dia bolts, other flange of cleat fixed to the angle hangers of 25x10x0.50 mm of required length with nuts & bolts of required size and other end of angle hanger fixed with intermediate G.I. channels 45x15x0.9 mm running at the spacing of 1200 mm centre to centre, to which the ceiling section 0.5 mm thick bottom wedge of 80 mm with tapered flanges of 26 mm each having lips of 10.5 mm, at 450 mm centre to centre, shall be fixed in a direction perpendicular to G.I. intermediate channel with connecting clips made out of 2.64 mm dia x 230 mm long G.I. wire at every junction, including fixing perimeter channels 0.5 mm thick 27 mm high having flanges of 20 mm and 30 mm long, the perimeter of ceiling fixed to wall/partition with the help of rawl plugs at 450 mm centre, with 25mm long dry wall screws @ 230 mm interval, including fixing of gypsum board to ceiling section and perimeter channel with the help of dry wall screws of size 3.5 x 25mm at 230 mm c/c, including jointing and finishing to a flush finish of tapered and square edges of the board with recommended jointing compound , jointing tapes , finishing with jointing compound in 3 layers covering upto 150 mm on both sides of joint and two coats of primer suitable for board, all as per manufacturer\"s specification and also including the cost of making openings for light fittings, grills, diffusers, cutouts made with frame of perimeter channels suitably fixed, all complete as per drawings, specification and direction of the Engineer in Charge but excluding the cost of painting with :12.5 mm thick tapered edge gypsum moisture resistant board
56Tiled false ceiling : Providing and fixing tiled false ceiling of specified materials of size 595x595 mm in true horizontal level, suspended on inter locking metal grid of hot dipped galvanized steel sections ( galvanized @ 120 grams/ sqm, both side inclusive) consisting of main \"T\" runner with suitably spaced joints to get required length and of size 24x38 mm made from 0.30 mm thick (minimum) sheet, spaced at 1200 mm center to center and cross \"T\" of size 24x25 mm made of 0.30 mm thick (minimum) sheet, 1200 mm long spaced between main \"T\" at 600 mm center to center to form a grid of 1200x600 mm and secondary cross \"T\" of length 600 mm and size 24x25 mm made of 0.30 mm thick (minimum) sheet to be interlocked at middle of the 1200x600 mm panel to form grids of 600x600 mm and wall angle of size 24x24x0.3 mm and laying false ceiling tiles of approved texture in the grid including, required cutting/making, opening for services like diffusers, grills, light fittings,fixtures, smoke detectors etc. Main \"T\" runners to be suspended from ceiling using GI slotted cleats of size 27 x 37 x 25 x1.6 mm fixed to ceiling with 12.5 mm dia and 50 mm long dash fasteners, 4 mm GI adjustable rods with galvanised butterfly level clips of size 85 x 30 x 0.8 mm spaced at 1200 mm center to center along main T, bottom exposed width of 24 mm of all Tsectionsshall be pre-painted with polyester paint, all complete for all heights as per specifications, drawings and as directed by Engineer-in-charge.
57Galvanise iron profile sheet : Providing and fixing precoated galvanised iron profile sheets (size, shape and pitch of corrugation as approved by Engineer-in-charge) 0.50 mm (+ 0.05 %) total coated thickness with zinc coating 120grams per M2 as per IS: 277, in 240 mpa steel grade, 5-7 microns epoxy primer on both side of the sheet and polyester top coat 15-18microns. Sheet should have protective guard film of 25 microns minimum to avoid scratches during transportation and should be supplied in single length upto 12 metre or as desired by Engineerin-charge. The sheet shall be fixed using self drilling /self tapping screws of size (5.5x 55 mm) with EPDM seal, complete upto any pitch in horizontal/ vertical or curved surfaces, excluding the cost of purlins, rafters and trusses and including cutting to size and shape wherever required.
58Galvanised steel sheet-Ridges plain : Providing and fixing precoated galvanised steel sheet roofing accessories 0.50 mm (+0.05 %) total coated thickness, Zinc coating 120 grams per sqm as per IS: 277, in 240 mpa steel grade, 5-7microns epoxy primer on both side of the sheet and polyester top coat 15-18 microns using self drilling/ self tapping screws complete :Ridges plain (500 - 600mm)
59Galvanised steel sheet-Gutter : Providing and fixing precoated galvanised steel sheet roofing accessories 0.50 mm (+0.05 %) total coated thickness, Zinc coating 120 grams per sqm as per IS: 277, in 240 mpa steel grade, 5-7microns epoxy primer on both side of the sheet and polyester top coat 15-18 microns using self drilling/ self tapping screws complete :Gutter (600 mm over all girth)
6012mm plaster : 12 mm cement plaster of mix :1:6 (1 cement: 6 coarse sand)
6115mm plaster : 15 mm cement plaster on rough side of single or half brick wall of mix :1:6 (1 cement: 6 coarse sand)
6218mm plaster : 18 mm cement plaster in two coats under layer 12 mm thick cement plaster 1:5 (1 cement : 5 coarse sand) and a top layer 6 mm thick cement plaster 1:3 (1 cement : 3 coarse sand) finished rough with sponge.
636mm plaster : 6 mm cement plaster of mix :1:3 (1 cement: 3 fine sand)
64Providing and mixing water proffing material in plaster : Extra for providing and mixing water proofing material in cement plaster work in proportion recommended by the manufacturers.
65Plaster of paris putty : Providing and applying plaster of paris putty of 2mm thickness over plastered surface to prepare the surface even and smooth complete.
66Acrylic emulsion paint : Wall painting with acrylic emulsion paint of approved brand and manufacture to give an even shade :Two or more coats on new work
67Textured exterior paint : Finishing walls with textured exterior paint of required shade :New work (Two or more coats applied @ 3.28 ltr/10 M2) over and including priming coat of exterior primer applied @ 2.20kg/10 M2
68Primer : Applying priming coat:With ready mixed pink or Grey primer of approved brand and manufacture on wood work (hard and soft wood)
69Acrylic emulsion paint : Wall painting with acrylic emulsion paint of approved brand and manufacture to give an even shade :Two or more coats on new work
70Synthetic enamel paint : Painting with synthetic enamel paint of approved brand and manufacture to give an even shade :Two or more coats on new work
71Demolishing cement concrete : Demolishing cement concrete including disposal of material within 50 metre lead:Nominal concrete 1:4:8 or leaner mix (i/c equivalent design mix)
72Demolishing RCC : Demolishing R.C.C. work manually/ by mechanical means including stacking of steel bars and disposal of unserviceable material within 50 metres lead as per direction of Engineer - in- charge.
73Cutting reinforcement : Extra for cutting reinforcement bars in R.C.C. or R.B. work (Payment shall be made on the cross sectional area of R.C.C. or R.B. work)
74Scrapping, cleaning & straightening reinforcement : Extra for scrapping, cleaning and straightening reinforcement from R.C.C. or R.B. work.
75Demolishing brickwork : Dismolishing brick work manually / by mechanical means including stacking of sericeable material and disposal of unserviceable material within 50 metre lead as per direction of engineer- in- charge.In cement mortar
76Dismantling door & windows <3sqm : Dismantling doors, windows and clerestory windows (steel or wood) shutter including chowkhats, architrave, holdfasts etc. complete and stacking within 50 metres lead :Of area 3 sq. metres and below
77Dismantling door & windows > 3sqm : Dismantling doors, windows and clerestory windows (steel or wood) shutter including chowkhats, architrave, holdfasts etc. complete and stacking within 50 metres lead :Of area beyond 3 sqm
78Taking out door,windows <3 sqm : Taking out doors, windows and clerestory window shutters (steel or wood) including stacking within 50 metres lead :Of area 3 sq. metres and below
79Taking out door,windows > 3 sqm : Taking out doors, windows and clerestory window shutters (steel or wood) including stacking within 50 metres lead :Of area beyond 3 sqm
80Dismantling steel work : Dismantling steel work in built up sections in angles, tees, flats and channels including all gusset plates, bolts, nuts, cutting rivets, welding etc. including dismembering and stacking within 50metres lead.
81Dismantling tile work : Dismantaling tile work in floor and roof laid in cement mortar including stackingmaterial within 50 metre lead .For thickness of tiles 10mm to 25mm.
82Dismantling stone slab : Dismantling stone slab flooring laid in cement mortar including stacking of serviceable material and disposal of unserviceable material within 50 metre lead:
83Dismantling flushing cistern : Dismantling of flushing cistern of any size including stacking of useful materials near the site and disposal of unserviceable materials within 50 metres lead.
84Dismantling CI sluice valve : Dismantling of C.I. sluice valve including stacking of useful materials within a lead of 50 metres. Above 150 mm diameter
85Dismantling alumiuium/Gypsum partitions : Dismantling alumiuium/Gypsum partitions, doors, windows, fixed glazing and false ceiling including disposal of unserviceable surplus material and stackingof serviceable material with in 50 m lead as directed by Engineer-in-charge.
86Disposal of building rubbish: Disposal of building rubbish / malba / similarunserviceable, dismantled or waste materials by mechanical means, including loading, transporting, unloading to approved municipal dumping ground or as approved by Engineer- in-charge, beyond 50 m initial lead, for all leads including all lifts involved.
87P&F glazing : Providing and fixing glazing in aluminium door, window, ventilator shutters and partitions etc. with EPDM rubber / neoprene gasket etc. complete as per the architectural drawings and the directions of engineer-in-charge . (Cost of aluminium snap beading shall be paid in basic item):With float glass panes of 5 mm thickness (weight not less than 12.50 kg/M2)
8812mm thick frameless toughened glass door : Providing and fixing 12 mm thick frameless toughened glass door shutter of approved brand and manufacture, including providing and fixing top & bottom pivot & double acting hydraulic floor spring type fixing arrangement and making necessary holes etc. for fixing required door fittings, all complete as per direction of Engineer-in-charge (Door handle, lock and stopper etc.to be paid separately).
89P&F Stainless steel 304 Grade H- type pull handle: Providing and fixing Stainless steel 304 Grade H- type pull handle of size min 32 mm dia and 1200mmlong ofapproved make including SS screws, including making holes of required size in shutter etc. complete as per direction of Engineer-in-Charge.
90SS bottom patch lock : Providing and fixing SS Bottom patch Lock with cylinder of approved make including necessary screws etc. all complete.
91SS floor mounted half dome stopper : Providing and fixing SS floor mounted half dome door stopper of dia 45mm including necessary screws etc. all complete.
92Aluminium extruded tubular and other aluminium sections : ALUMINIUM WORKProviding and supplying aluminium extruded tubular and other aluminium sections as per the architectural drawings and approved shop drawings , the aluminium quality as per grade 6063 T5 or T6 as per BS 1474,including super durable powder coating of 60-80 microns conforming to AAMA 2604 of required colour and shade as approved by the Engineer-in-Charge. ( The item includes cost of material such as cleats, sleeves, screws etc. necessary for fabrication of extruded aluminium frame work. Nothing extra shall be paid on this account). The weight of aluminium extruded section shall be taken for purpose of payment.
93Structural glazing : ALUMINIUM WORKDesigning, fabricating, testing, protection, installing and fixing in position semi (grid) unitized system of structural glazing (with open joints) for linear as well as curvilinear portions of the building for all heights and all levels including:(a) Structural analysis, design and preparation of shop drawings for the specified design loads conforming to IS 875 part III (the system must passed the proof test at 1.5 times design wind pressure without any failure), including functional design of the aluminum sections for fixing glazing panels of various thicknesses, aluminium cleats, sleeves and splice plates etc. gaskets, screws, toggles, nuts, bolts, clamps etc., structural and weather silicone sealants, flashings, fire stop (barrier)-cum-smoke seals, microwave cured EPDM gaskets for water tightness, pressure equalisation & drainage and protection against fire hazard including:(b) Fabricating and supplying serrated M.S. hot dip galvanised / Aluminium alloy of 6005 T5 brackets of required sizes, sections and profiles etc. to accommodate 3 Dimentional movement for achieving perfect verticality and proper fixing of structural glazing system with the RCC/ masonry/structural steel framework of building structure, using stainless steel anchor fasteners/ bolts, nylon seperator to prevent bimetallic contacts with nuts and washers etc. of stainless steel grade 316, of the required capacity and in required numbers.(c) Providing and filling, two part pump filled, structural silicone sealant and one part weather silicone sealant compatible with the structural silicone sealant of required bite size in a clean and controlled factory / work shop environment , including double sided spacer tape, setting blocks and backer rod, all of approved grade, brand and manufacturer, as per the approved sealant design, within and all around the perimeter for holding glass.(d) Providing and fixing in position flashings of solid aluminium sheet 1 mm thick and of sizes, shapes and profiles, as required as per the site conditions, to seal the gap between the building structure and all its interfaces with curtain glazing to make it watertight.(e) Making provision for drainage of moisture/ water that enters the curtain glazing system to make it watertight, by incorporating principles of pressure equalization, providing suitable gutter profiles at bottom (if required), making necessary holes of required sizes and of required numbers etc. complete.This item includes cost of all inputs of designing, labour for fabricating and installation of aluminium grid, installation of glazed units, T&P, scaffolding and other incidental charges including wastages etc., enabling temporary structures and services, cranes or cradles etc. as described above and as specified. The item includes the cost of getting all the structural and functional design checked and all the shop drawings vetted by the Principals of the structural glazing system.The item also includes the cost of all mock ups at site, cost of all samples of the individual components for testing in an approved laboratory, field tests on the assembled working structural glazing as specified, cleaning and protection till the handing over of the building for occupation. In the end, the Contractor shall provide a water tight structural glazing having all the performance characteristics etc. all complete as required, as per the Architectural drawings, as per item description, as specified, as per the approved shop drawings and as directed by the Engineer-in-Charge.
94Vision glass panels : ALUMINIUM WORKSProviding, assembling and supplying vision glass panels (IGUs) comprising of hermetically-sealed 6-12-6 mm insulated glass (double glazed) vision panel units of size and shape as required and specified, comprising of an outer high performance heat strengthened float glass 6mm thick, of approved colour and shade with reflective soft coating on surface # 2 of approved colour and shade, an inner Heat strengthned clear float glass 6mm thick, spacer tube 12mm wide, dessicants, including primary seal and secondary seal (structural silicone sealant) etc. all complete for the required performances, as per the Architectural drawings, as per the approved shop drawings, as specified and as directed by the Engineer-in-Charge. The IGUs shall be assembled in the factory/ workshop of the glass processor. (Payment for fixing of IGU Panels in the curtain glazing is included in cost of item No.1) For payment, only the actual area of glass on face # 1 of the glass panels (excluding the areas of the grooves and weather silicone sealant) provided and fixed in position, shall be measured in M2.(i) Coloured tinted float glass 6mm thick substrate with reflective soft coating on face # 2, + 12mm Airgap + 6mm Heat Strengthened clear Glass of approved make having properties as visible Light transmittance (VLT) of 25 to 35 %, Light reflection internal 10 to 15%, light reflection external 10 to 20 %, shading coefficient (0.25- 0.28) and U value of 3.0 to 3.3 W/m2 degree K etc.
95Extra for openable side / top hung vision glass panels : ALUMINIUM WORKSExtra for openable side / top hung vision glass panels (IGUs) including providing and supplying at site all accessories and hardwares for the openable panels as specified and of the approved make such as heavy duty stainless steel friction hinges, min 4 -point cremone locking sets with stainless steel plates, handles, buffers etc. including necessary stainless steel screws/ fasteners, nuts, bolts, washers etc. all complete as per the Architectural drawings, as per the approved shop drawings, as specified and as directed by the Engineer- in-Charge.
96cement based water proofing treatment on roofs, balconies, terraces : P/L integral cement based water proofing treatment on roofs, balconies, terraces etc. :With average thickness of 120 mm and minimum thickness at khurra as 65 mm.
97Grading roof for water proofing treatment withCement concrete : Grading roof for water proofing treatment withCement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20mm nominal size)
98Blackout Roller Blinds : Providing & fixing of Blackout Roller Blinds fabric made up of 100% Polyester with Acrylic coated of 0.32mm(PVC free) of thickness 0.50mm ±5% and weighing 270-295gsm with openness factor of 0% .Shrinkage %Warp<0.5 & Weft <0.5,Color fastness>5-6. The control clutch drive unit engineered heavy duty chain drive pulley operating system consisting of gear clutch housing and locking plug containing minimum 6 ribs and inserted at minimum of 37mm into roller tube. It is self-lubricating Exclusive clutch with safety pins for secure bracket installation and unlocking pin for quick manual removal. Universal clutch is most convenient for large windows down to the smallest windows. It shall be driven by a ball chain pulley with ball chain and can be positioned at Right hand or Left hand side of the shade. Clutch gear ration 1.75:1 for reduced operating force on larger blinds. Tube bearing plug idler Exclusive self-lubricating spring loaded plastic bearing end plug with positive locking wheel allows for adjustment and provides for a secure installation and removal of shade. Tube bearing plug contain minimum 6 ribs and inserted a minimum of 37mm into roller tube. Mounting hardware brackets universal brackets including end plug bracket with lock down retainer device. Brackets finish of powder coated metal installation brackets made of stamped and hardened steel with 46mm projection for wall, ceiling and side fitting with screws and end cap covers. Roller tube circular-shaped aluminium tube extruded from alloy 6060 and temper T66 – EN755 of 37mm inside diameter and outside diameter 40.2mm extruded tube to have a 1.6mm wall thickness with standard anodized natural finish. Heavily reinforced with minimum six internal ribs providing additional tensile strength and allows for secure placements of clutch and end plug. Bottom rail flat-shaped extruded aluminium from alloy 6060 and temper T66 – EN755 of dimension 13mm * 30mm and wall thickness of 1.5mm and weight of 390g/m. Rail standard finish of powder coat white color and provided cover. Ball chain shall be 2mm diameter cord with 4.5mm diameter acetal balls molded coaxially to it on 11.8mm pitch to form an endless ball chain. It is used for raising or lowering action of the shades. Plastic parts all plastic components are UV-stable compounds available white colour.
99Room Signages : Room Signages (Stainless Steel with single color/Multi color engravings)Providing and Fixing Seating, G.Toilet & Ladies Toilet with symbol/Kitchen/Fire exist/rest room or for anyother area as per the direction of EIC.The SS plate of approximate size 200mmx400mm shall be 304 grade of approved shape as per drawing.single color/Multi color engraved signage Font and letter sizing shall begotaproved by the architect-sampleshall be submitted. Rate shall include all hardware and necessary arrangementfor fixing.
100DIGITAL 2D/3D WALL PAPER : DIGITAL 2D/3D WALL PAPER : Providing & fixing 2d/3d digital printing printing on approved paper/canvas/fabric media as per suggested graphic work on suggested surface .Contractor shall provide graphic work detail & 5 M2m sample for approval the work shall be done inclusive of all rate with accesesories,tool tackel at allheight compelte.
101Opaque partition : Providing and fixing in position opaque partition consisting offrame work in extruded aluminum sections1.6 mm th , of approx size 50 x50 mm , placed at center to center at notmore than 600mm bothways, joined usingangle 35x35x 3 mm . Securly fixed to wall and , floor and ceiling complete in all respect . The rates shall be inclusive of cutting , punching of holes for drawings conduits and boxes for electrical works etc.
102Hilti-10 mm dia bar : GLASS GRAPHICSSupplying and fixing chemical rebaq fastening with Hilti-HY - 150 and complete as per manufacturer specification10 mm dia bar
103Hilti-12 mm dia bar : GLASS GRAPHICSSupplying and fixing chemical rebaq fastening with Hilti-HY - 150 and complete as per manufacturer specification12 mm dia bar
104Hilti-16 mm dia bar : GLASS GRAPHICSSupplying and fixing chemical rebaq fastening with Hilti-HY - 150 and complete as per manufacturer specification16 mm dia bar
105Hilti-20 mm dia bar : GLASS GRAPHICSSupplying and fixing chemical rebaq fastening with Hilti-HY - 150 and complete as per manufacturer specification20 mm dia bar
106Hilti-25 mm dia bar : GLASS GRAPHICSSupplying and fixing chemical rebaq fastening with Hilti-HY - 150 and complete as per manufacturer specification25 mm dia bar
107Providing and laying Brick Tile cladding : GLASS GRAPHICSProviding and laying Brick Tile cladding (size and thickness to be specified by the manufacturer), water absorption 3% to 6% conforming to IS: 1237:2001, of approved brand & manufacturer, in brick colours and shade as approved by the architect, on walls laid with cement based high polymer modified quick set tileadhesive (water based) conforming to IS: 15477, in average 6 mm thickness, including grouting of joints of 3mm wide using epoxy grout mix of 0.70 kg of organic coated filler of desired shade (0.10 kg of hardener and 0.20 kg of resin per kg), including filling / grouting and finishing complete as per direction of Engineer-in-charge.
108Counter with storage : Counter with storage:Providing and fixing of counter with storage cabinet formed of 18mm thick prelaminated MDF board formwork/carcass/adjustable shelves/shutters with all exposed edges finished with 2mm thick PVC edge band (factory finished) as per details shown in drawing . Top of cabinet to be formed of 19mm thick commercial plywood/board. The storage also to have drawer pedestals made of 18mm thick prelaminated MDF board with all exposed edges finished with 2mm thick PVC edge band (factory finished) as shown in drawing. Top of cabinet to be formed of 19mm thick commercial plywood/board. Rear backing of cabinet to be formed with 12mm thick marine plywood. Counter top, facia and 200mm high partial splash board to be finished with Prepolished Granite Stone of approved shade & make as per details. All laminate shades to be of approved shade and colour. Cabinet to have concealed dustbin behind flap door formed of stainless steel in hairline finish as approved.All exposed wood surfaces to be finished with spray applied melamine polish. Also to provide skirting in laminate finish as per details. (Front area upto counter top to be measured and paid for). Storage to be complete with hardware installed as directed to consist of the following: Shutter to have 2 nos of automatic spring loaded hinge of approved make installed strictly a per manufacturers guidelines with requisite tools/jigs. Each set of shutters to be provided with 1no. multi purpose lock as specified, SS handles, auto bolt, etc.Hardware: The storage to have all necessary hardware/ Locks/ Handles/ Hinges complete as per details drawing & shall be as per the approved model/make. (Hettich/Hafele make).Counter with storage of size 600mm (D) x 850mm (H)( approximately) with 19mm thick prepolished Granite stone (Basic price of Granite stone @ Rs.1600/ M2t + taxes)
109Kitchen sink with drain board : Providing and fixing Stainless Steel AISI 304 (18/8) kitchen sink as per IS: 13983 with C.I. brackets and stainless steel plug 40 mm, including painting of fittings and brackets, cutting and making good the walls wherever required.Kitchen sink with drain board-510x1040 mm bowl depth 250 mm
110Full Height Storage (Laminate finish) : Full Height Storage (Laminate finish)-600 mm Deep:Providing and fixing full height storage cabinet formed of 18mm plywood formwork/carcass with adjustable shelves as per details.Shutter of storage cabinet to be formed of 19mm commercial board/plywood finished with 1mm thick laminate of approved shade. All internal surfaces to be post laminated with 0.8mm thick HP laminate to approved shade. All external exposed surfaces to be finished with 1mm thick HP laminate to approved shade and all exposed edges to be finished with 2mm thick PVC edge band (factory finished) as per details. Each set of shutters to be provided with 1 no multi purpose lock as specified, 6mm thick SS D type handles, auto bolt as per details. Exposed wood surfaces to be finished with spray applied melamine polish (front area to be measured and paid for).Hardware: All hardware shall be as per the appoved model/make (Hettich/Hafele make)
111Overhead Storage : Overhead Storage : 450mm(D) x600/800mm (H) or as approved by EIC-Providing and fixing overhead storage cabinet formed of 18mm thick prelaminated MDF board formwork/carcass/adjustable shelves/shutters with all exposed edges finished with 2mm thick PVC edge band (factory finished) as per details shown in drawing .Shutter of overhead cabinet to be formed of 18mm thick prelaminated MDF board with all exposed edges finished with 2mm thick PVC edge band (factory finished) as per details shown in drawing. Exposed wood surfaces to be finished with spray applied melamine polish. The storage to have all necessary hardware, locks, handle etc. complete as per details. (front area to be measured).Cabinet to have provision for concealed lighting with providing & fixing removable cover made of 6mm thick milky white acrylic sheet fixed on 12x12x1.2mm Aluminium L-angle as indicated in the drawing and as per details.Storage to be complete with hardware installed as directed to consist of the following: Shutter to have 2 nos of automatic spring loaded hinge of approved make installed strictly a per manufacturers guidelines with requisite tools/jigs. Each set of shutters to be provided with 1no. multi purpose lock as specified, SS handles, auto bolt, etc.Hardware: The storage to have all necessary hardware/ Locks/ Handles/ Hinges complete as per details drawing & shall be as per the approved model/make.
112Removing interlocking paver block or precast concrete : Removing interlocking paver block or precast concrete or stone slabs in floor etc. including stacking within 50 metres lead : Thickness above 40 mm up to 75 mm
113PLUMBING WORKS
114P&F white vitreous china extended wall mountedwater closet : SANITARY INSTALLATIONProviding and fixing white vitreous china extended wall mounted water closet of size 360x580x360mm of approved shape including providing and fixingof metropole flush valve dual flow 32mm size (concealed body) with exposed shut off provision & round flange (3.0/6.0 lts. per flushing),including seat cover , and cistern fittings, nut bolt gasket,chair etc complete. ( MAKE-1: JAQUAR, MODEL NO. WALL MOUNTED WC : FLS-WHT-5953 & METROPOLE FLUSH VALVE :FLV-CHR-1085N. MAKE-2 : PARRYWARE, WALL MOUNTED WC : C88251C & METROPOLE FLUSH VALVE :T3308A1 OREQUIVALENT.)
115Hand shower : SANITARY INSTALLATIONHand Shower (Health Faucet) (ABS Body) with 8mm Dia, 1.5 Meter Long Spirochrome flex tube & Wall Hook. ( MAKE-1: JAQUAR)
116Unplasticised PVC connection pipe : SANITARY INSTALLATIONProviding and fixing uplasticised PVC connection pipe with brass unions : 45 cm length , 15 mm nominal bore
117Oval shaped wash basin : SANITARY INSTALLATIONProviding and fixing white vitreous china Oval shaped wash basin for top/under counter mounting with15 mm C.P. brass single hole basin mixer of approved quality and make, including painting of fittings and brackets, cutting and making good the walls whereever required. ( MAKE-1: JAQUAR, MODEL NO. WASH BASIN : FSS-WHT-29601 & BASIN MIXER :FLR-CHR-5001B & WASTE COUPLING : ALD-CHR-705. MAKE-2: PARRYWARE, MODEL NO. WASH BASIN : C041M1C & BASIN MIXER :G3165A1 & WASTE COUPLING : T9953A1 OREQUIVALENT.) White Vitreous China Oval shaped Wash basin size 545 x 545 x 180mm with 15mm CP Brass single hole basin mixer
118Mirror : SANITARY INSTALLATION Providing and fixing looking mirror of superior glass as of required size of approved quality complete with 6 mm thick hard board ground fixed to wooden cleats with C.P. brass screws and washers complete.
119Toilet paper : SANITARY INSTALLATIONProviding and fixing toilet paper holder :C.P. brass
120Liquid soap container/dispenser : SANITARY INSTALLATIONProviding & fixing Nickel Chromium Platedliquid soap container/dispenser with metallic bottle of 51 mm dia & 122 mm height (Total height 162mm) of approved brand & make112 mm distance from wall of standard shape with bracket (Nickel chromium plating should pass Salt Spray Test for 200 hours) of the same materials with snap fittings of approved quality and colour, complete as per direction of Engineer in Charge. ( MAKE-1 : JAQUAR, MODEL NO. - ACN-CHR-1137N. MAKE-2 : PARRYWARE, MODEL NO. - T6706A1OR EQUIVALENT.
121Bottle trap : SANITARY INSTALLATIONProviding and fixing CP Brass 32mm size Bottle Trap of approved quality & make and as per the direction of Engineer-in-charge. ( MAKE-1: JAQUAR, MODEL NO. BOTTLE TRAP : ALD-CHR-769L300X190.MAKE-2: PARRYWARE, MODEL NO. BOTTLE TRAP : T3202A1 OREQUIVALENT.)
122CP brass towel ring : SANITARY INSTALLATIONProviding, Fixing of CP brass Towel Ring with CP brass wall brackets and providing & fixing CP brass screws complete as required. ( MAKE-1: JAQUAR, MODEL NO. TOWEL RING : ACN-CHR-1121N. MAKE-2: PARRYWARE, MODEL NO. TOWEL RING : T6002A1 OREQUIVALENT.)
123WC pan connector : SANITARY INSTALLATIONProviding ,Fixing of straight / offset type flexible single body push fit type WC pan connector ofwith integral single mould sealing fins made of flexible EVA body to be fixed with manufacture supplied grease, including rubber bush / adaptor for use with uPVC pipe as supplied with the pan connector.
124CP brass bib cock : SANITARY INSTALLATIONProviding and fixing C.P. brass bib cock of approved quality conforming to IS:8931 :15 mm nominal bore (MAKE-JAQUAR or EQUIVALENT)
125CP brass long body bib cock : SANITARY INSTALLATIONProviding and fixing C.P. brass long body bib cock of approved quality conforming to IS standards and weighing not less than 690 gms.15 mm nominal bore (MAKE-JAQUAR or EQUIVALENT)
126C.P. brass angle valve : SANITARY INSTALLATIONProviding and fixing C.P. brass angle valve for basin mixer and geyser points of approved quality conforming to IS:8931 15mm nominal bore
127Water Heater : SANITARY INSTALLATIONSupply,Installation, testing and commissioning ofWater Heater complete with heavy gauge hot and cold water flexible pipe connections, Nano polymer coated tank, 8 bar pressure ,of approved make complete with all necessary material as directed by Engineer - in - Charge. 25-Litre Storage capacity(MAKE-BAJAJ, USHA, CROMPTON, PHILIPHS, HAVELLS)
128uPVC SWR Pipes class B : INTERNAL DRAINAGEProviding and fixing uPVC SWR Pipes class B (IS:13592) with all injection moulded fittings(door or plain) viz elbolws, bends, tees, junctions, shoe bends, couplers, offsets, cowel etc. complete including jointing with solvent cement including GI supports,cutting and making good the walls wherever required. Nothing extra will be paid for supports.(Vertical Soil, waste, balcony waste & rain water pipes) 110 OD
129P&F 100mm dia nominal bore uPVC pipe-40 OD : INTERNAL DRAINAGEProviding and fixing 100mm dia nominal bore uPVC pipe (Class-III)-IS:4985 inlet fitting approximately upto 300mm long above the trap with one or more 40 OD/ 50OD/63 OD/75OD holes for jointing waste pipes from waste appliances jointed and sealed with epoxy based sealant complete.For waste pipes 40 OD uPVC pipe
130P&F 100mm dia nominal bore uPVC pipe-63 OD : INTERNAL DRAINAGEProviding and fixing 100mm dia nominal bore uPVC pipe (Class-III)-IS:4985 inlet fitting approximately upto 300mm long above the trap with one or more 40 OD/ 50OD/63 OD/75OD holes for jointing waste pipes from waste appliances jointed and sealed with epoxy based sealant complete.For waste pipes 63 OD uPVC pipe
131uPVC Floor drain : INTERNAL DRAINAGEProviding and fixing uPVC floor drain consisting of PVC reducing elbow 110 x 63mm complete, as directed by the Project Manager.
132uPVC SWR P Trap : INTERNAL DRAINAGEProviding and fixing uPVC SWR P Trap with minimum 50mm water seal conforming to IS 13592110 mm inlet & 110 mm outlet
133Trap of self cleansing : INTERNAL DRAINAGEProviding and fixing trap of self cleansing design with screwed down or hinged grating with or without vent arm complete, including cost of cutting and making good the walls and floors :
134P&F PVCCOP /FCO with suitable insert keys : INTERNAL DRAINAGEProviding and fixing PVCCOP /FCO with suitable insert keys for opening as per approved sample, properly jointed to soil andwaste pipe asper requirement, complete as per instructions of the Engineer in charge. For 110 mm dia pipe
135PVC rain water pipes : RAIN WATER WORKProviding and fixing on wall face unplasticised Rigid PVC rain water pipes confoMing to IS : 13592 Type A, including jointing with seal ring confoMing to IS : 5382, leaving 10 mm gap for theMal expansion, (i) Single socketed pipes.110 mm diameter
136unplasticised - PVC moulded fittings/ accessories-110 mm dia : RAIN WATER WORKProviding and fixing on wall face unplasticised - PVC moulded fittings/ accessories for unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A including jointing with seal ring conforming to IS : 5382 leaving 10 mm gap for thermal expansion. Single Push fit coupler110 mm dia
137unplasticised - PVC moulded fittings/ accessories-110*110*110 : RAIN WATER WORKProviding and fixing on wall face unplasticised - PVC moulded fittings/ accessories for unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A including jointing with seal ring conforming to IS : 5382 leaving 10 mm gap for thermal expansion. Single Tee with door110x110x110 mm
138wall face unplasticised - PVC moulded fittings bend 87.5 deg : RAIN WATER WORKProviding and fixing on wall face unplasticised - PVC moulded fittings/ accessories for unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A including jointing with seal ring conforming to IS : 5382 leaving 10 mm gap for thermal expansion. Bend 87.5 Deg110 mm dia
139wall face unplasticised - PVC moulded fittings shoe (plain) : RAIN WATER WORKProviding and fixing on wall face unplasticised - PVC moulded fittings/ accessories for unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A including jointing with seal ring conforming to IS : 5382 leaving 10 mm gap for thermal expansion. Shoe (Plain)110 mm dia
140Inlet mouth of rain water pipe : RAIN WATER WORKProviding and fixing to the inlet mouth of rain water pipe cast iron grating 15 cm diameter and weighing not less than 440 grams.
141unplasticised -PVC pipe clips : RAIN WATER WORKProviding and fixing unplasticised -PVC pipe clips of approved design to unplasticised - PVC rain water pipes by means of 50x50x50 mm hard wood plugs, screwed with M.S. screws of required length, including cutting brick work and fixing in cement mortar 1:4 (1 cement : 4 coarse sand) and making good the wall etc. complete.110 mm dia
142Khurras : RAIN WATER WORKMaking khurras 45x45 cm with average minimum thickness of 5 cm cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate of 20 mm nominal size) over P.V.C. sheet 1 m x1 m x 400 micron, finished with 12 mm cement plaster 1:3 (1 cement : 3 coarse sand) and a coat of neat cement, rounding the edges and making and finishing the outlet complete.
143CPVC pipes-15mm nominal bore : WATER SUPPLYProviding and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in Charge.Concealed work, including cutting chases and making good the walls etc.15mm nominal bore
144CPVC pipes-20mm nominal bore : WATER SUPPLYProviding and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in Charge.Concealed work, including cutting chases and making good the walls etc.20mm nominal bore
145CPVC pipes-25mm nominal bore : WATER SUPPLYProviding and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in Charge.Concealed work, including cutting chases and making good the walls etc.25mm nominal bore
146CPVC pipes-32mm nominal bore : WATER SUPPLYProviding and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in Charge.Concealed work, including cutting chases and making good the walls etc.32 mm nominal bore
147CPVC pipes-40mm nominal bore : WATER SUPPLYProviding and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in Charge.Concealed work, including cutting chases and making good the walls etc.40 mm nominal bore
148CPVC pipes internal work 15mm nominal bore : WATER SUPPLYProviding and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and testing of joints complete as per direction of Engineer in Charge.Internal work - Exposed on wall15mm nominal bore
149CPVC pipes internal work 20mm nominal bore : WATER SUPPLYProviding and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and testing of joints complete as per direction of Engineer in Charge.Internal work - Exposed on wall20mm nominal bore
150CPVC pipes internal work 25mm nominal bore : WATER SUPPLYProviding and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and testing of joints complete as per direction of Engineer in Charge.Internal work - Exposed on wall25mm nominal bore
151CPVC pipes internal work 32mm nominal bore : WATER SUPPLYProviding and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and testing of joints complete as per direction of Engineer in Charge.Internal work - Exposed on wall32 mm nominal bore
152CPVC pipes internal work 40mm nominal bore : WATER SUPPLYProviding and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and testing of joints complete as per direction of Engineer in Charge.Internal work - Exposed on wall40mm nominal bore
153P&F Forged Brass Ball Valve-15mm nominal bore : WATER SUPPLYProviding and fixing Forged Brass Ball Valve (Screwed). with setting and gland of superior quality having minimum working pressure of 16 kg/cm2. 15 mm nominal bore
154P&F Forged Brass Ball Valve-20mm nominal bore : WATER SUPPLYProviding and fixing Forged Brass Ball Valve (Screwed). with setting and gland of superior quality having minimum working pressure of 16 kg/cm2. 20 mm nominal bore
155P&F Forged Brass Ball Valve-25mm nominal bore : WATER SUPPLYProviding and fixing Forged Brass Ball Valve (Screwed). with setting and gland of superior quality having minimum working pressure of 16 kg/cm2. 25 mm nominal bore
156P&F Forged Brass Ball Valve-32mm nominal bore : WATER SUPPLYProviding and fixing Forged Brass Ball Valve (Screwed). with setting and gland of superior quality having minimum working pressure of 16 kg/cm2. 32 mm nominal bore
157P&F Forged Brass Ball Valve-40mm nominal bore : WATER SUPPLYProviding and fixing Forged Brass Ball Valve (Screwed). with setting and gland of superior quality having minimum working pressure of 16 kg/cm2. 40 mm nominal bore
158Butterfly valve : WATER SUPPLYSupplying, fixing, testing and commissioning of butterfly valve of PN 1.6 rating with bronze/gunmetal seat duly ISI markedcompletewithnuts,bolts,washers,gaskets conforming to IS 13095 of following sizes as required :50mm dia.
159Water storage tank : WATER SUPPLYProviding and placing on terrace (at all floor levels) polyethylene water storage tank, ISI : 12701 marked, with cover and suitable locking arrangement and making necessary holes for inlet, outlet and overflow pipes but without fittings and the base support for tank.
160Auto air vent : WATER SUPPLYProviding & fixing Auto Air vent for cold water supply risers, suitable for pressure not less than 15 Kg/Sq.cm.15mm
161Moterise Ball valve-40mm dia : WATER SUPPLYProviding, fixing, testing and commissioning moterise Ball valve of following sizes, for filling of overhead tanks complete with high & low level switchs & pressure switch to control the valve. The level controller shalll be installed in over head tank. The level switch will close the valve when water level is high & open the valve when level is low in the tank. The system should be complete in all respect with accessories, 220V AC / 24 V DC, IP 67 water level control unit, Control Panel, copper control wiring in whether proof casing etc.40mm dia.
162Moterise Ball valve-50mm dia : WATER SUPPLYProviding, fixing, testing and commissioning moterise Ball valve of following sizes, for filling of overhead tanks complete with high & low level switchs & pressure switch to control the valve. The level controller shalll be installed in over head tank. The level switch will close the valve when water level is high & open the valve when level is low in the tank. The system should be complete in all respect with accessories, 220V AC / 24 V DC, IP 67 water level control unit, Control Panel, copper control wiring in whether proof casing etc.50mm dia.
163G.I. distribution branch with G.I. main 25 to 40 mm nominal bore : EXTERNAL PLUMBING WORK UPTO FIRST MANHOLEMaking connection of G.I. distribution branch with G.I. main of following sizes by providing and fixing tee, including cutting and threading the pipe etc. complete :25 to 40 mm nominal bore
164Excavating trenches : EXTERNAL PLUMBING WORK UPTO FIRST MANHOLEExcavating trenches of required width for pipes, cables, etc including excavation for sockets, anddressing of sides, ramming of bottoms, depth up to 1.5 m, including getting out the excavated soil, and then returning the soil as required, in layers not exceeding 20 cm in depth, including consolidating each deposited layer by ramming, watering, etc. and disposing of surplus excavated soil as directed,within a lead of 50 m :All kinds of soilPipes, cables etc. exceeding 80 mm dia but not exceeding 300 mm dia
165Excavation : EXTERNAL PLUMBING WORK UPTO FIRST MANHOLEEarth work in excavation by mechanical means (Hydraulic excavator) /manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 Sqm on plan), including dressing of sides and ramming of bottoms, lift upto 1.5 m, including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 m.All kind of Soil
166P&F uPVC SWR Pipes class B : EXTERNAL PLUMBING WORK UPTO FIRST MANHOLEProviding and fixing uPVC SWR Pipes class B (IS:13592) with all injection moulded fittings(door or plain) viz elbolws, bends, tees, junctions, shoe bends, couplers, offsets, cowel etc. complete including jointing with solvent cement including GI supports,cutting and making good the walls wherever required. Nothing extra will be paid for supports.(Vertical Soil, waste, balcony waste & rain water pipes) 150 mm dia
167P&L cement concrete 150mm dia : EXTERNAL PLUMBING WORK UPTO FIRST MANHOLEProviding and laying cement concrete 1:5:10 (1 cement : 5 coarse sand : 10 graded stone aggregate 40 mm nominal size) all-round S.W. pipes including bed concrete as per standard design :150 mm diameter S.W. pipe
168P&F square-mouth S.W.gully trap : EXTERNAL PLUMBING WORK UPTO FIRST MANHOLEProviding and fixing square-mouth S.W.gully trapclass SP-1 complete with C.I. grating brick masonry chamber with water tight C.I. cover with frame of 300x300 mm size (inside) the weight of cover to be not less than 4.50 kg and frame to be not less than 2.70 kg as per standard design: 100x100 mm size P type. With common burnt clay F.P.S. (non modular) bricks of class designation 7.5
169P&L non-pressure NP2 class : EXTERNAL PLUMBING WORK UPTO FIRST MANHOLEProviding and laying non-pressure NP2 class (light duty) R.C.C. pipes with collars jointed with stiff mixture of cement mortar in the proportion of 1:2 (1 cement : 2 fine sand) including testing of joints etc. complete :For stoM water pipe150 mm dia. R.C.C. pipe
170P&L cement concrete 150mm dia RCC pipe : EXTERNAL PLUMBING WORK UPTO FIRST MANHOLEProviding and laying cement concrete 1:5:10 (1 cement : 5 coarse sand : 10 graded stone aggregate 40 mm nominal size) up to haunches of RCC. pipes including bed concrete as per standard design :150 mm dia. R.C.C. pipe
171Brick masonary : EXTERNAL PLUMBING WORK UPTO FIRST MANHOLEConstructing brick masonry manhole in cement mortar 1:4 ( 1 cement : 4 coarse sand ) with R.C.C. top slab with 1:2:4 mix (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominalsize), foundation concrete 1:4:8 mix (1 cement : 4 coarse sand : 8 graded stone aggregate 40 mm nominal size), inside plastering 12 mm thick with cement mortar 1:3 (1 cement : 3 coarse sand) finished with floating coat of neat cement and making channels in cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) finished with a floating coat of neat cement complete as per standard design :Inside size 90x80 cm and 45 cm deep including C.I. cover with frame (light duty) 455x610 mm internal dimensions,total weight of cover and frame to be not less than 38 kg (weight of cover 23 kg and weight of frame 15 kg) :With common burnt clay F.P.S.(non modular) bricks of class designation 7.5
172Extra for depth for manhole : EXTERNAL PLUMBING WORK UPTO FIRST MANHOLEExtra for depth for manholes:Size 90x80x90 cmWith common burnt clay F.P.S.(non modular) bricks of class designation 7.5
17312mm cement plaster : EXTERNAL PLUMBING WORK UPTO FIRST MANHOLE12 mm cement plaster finished with a floating coat of neat cement of mix :1:3 (1 cement: 3 fine sand)
174Providing orange colour safety foot rest: EXTERNAL PLUMBING WORK UPTO FIRST MANHOLEProviding orange colour safety foot rest of minimum 6 mm thick plastic encapsulated as per IS : 10910, on 12 mm dia steel bar conforming to IS: 1786, having minimum cross section as 23 mmx25 mm and over all minimum length 263 mm and width as 165 mm with minimum 112 mm space between protruded legs having 2 mm tread on top surface by ribbing or chequering besides necessary and adequate anchoring projections on tail length on 138 mm as per standard drawing and suitable to with stand the bend test and chemical resistance test as per specifications and having manufacture\"s permanent identification mark to be visible even after fixing, including fixing in manholes with 30x20x15 cm cement concrete block 1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size) complete as per design.
175Road gully chamber 45*45*77.5 cm : EXTERNAL PLUMBING WORK UPTO FIRST MANHOLEConstructing brick masonry road gully chamber 45x45x77.5 cm with bricks in cement mortar 1:4 (1 cement : 4 coarse sand ) with precast R.C.C. vertical grating complete as per standard design : with common burnt clay F.P.S.(non module) brick of class designation 7.5
176Making connection of drain : EXTERNAL PLUMBING WORK UPTO FIRST MANHOLEMaking connection of drain or sewer line with existing manhole including breaking into and making good the walls, floors with cement concrete 1:2:4 mix (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) cement plastered on both sides with cement mortar 1:3 (1 cement : 3 coarse sand), finished with a floating coat of neat cement and making necessary channels for the drain etc. complete :For pipes 100 to 250 mm diameter
177Senser Operated Urinal : Providing and fixing white vitreous china sensor operated urinal of approx. size 320 x 335 x 620 mm mm having pre & post flushing with water (250 ml & 500 ml consumption), having water inlet from back side, including fixing to wall with suitable brackets all as per manufacturers specification and direction of Engineer-in-charge. ( MAKE-1: CERA, Cat. No. A4010101)
178Curved shaped urinal partition : Providing and fixing Curved shaped urinal partition with frosted glassWith dimension of H: 900 W: 450 as per direction of Engineer-in-charge and finished smooth.Glass: 8mm / 10mm ( MAKE-1: CERA, Cat. No. A4010101 JSE-CHR-110UC450X)
179FURNITURE WORKS
180Café table Dimension:(L) 1500mmX (W) 750mmX (H) 750mm : Café table Dimension:(L) 1500mmX (W) 750mmX (H) 750mmSupplying, and placing in position of cafe table as per image/drawing.The table topare made out of25mm thk prelaminated particle boardwith 2mm thk pvc edge bandingwith ms powder coated \"C\" shape legs of size 50mm x 50mmComprising of metal powder coated cross connectors of size 40mm X 40mm .The working edges shall be provided with machine pressed 2mm thick PVC edging using special hot melt glue at hot temperature.The product should be from the manufacture which have BIFMA Compliance Certification, GREENGUARD/GREENPRO/FSC Certification,AIOTA Certification and from the approved make of Durian, Godrej,HNI. The product should be as per above given specification under the guidance of project architect & Engineer in charge.
181Café table Dimension:(L) 750mmX (W) 750mmX (H) 750mm : Café tableDimension:(L) 750mmX (W) 750mmX (H) 750mmSupplying, and placing in position of cafe table as per image/drawing.The table topare made out of25mm thk prelaminated particle boardwith 2mm thk pvc edge bandingwith ms powder coated \"C\" shape legs of size 50mm x 50mmComprising of metal powder coated cross connectors of size 40mm X 40mm .The working edges shall be provided with machine pressed 2mm thick PVC edging using special hot melt glue at hot temperature.The product should be from the manufacture which have BIFMA Compliance Certification, GREENGUARD/GREENPRO/FSC Certification,AIOTA Certification and from the approved make of Durian, Godrej,HNI. The product should be as per above given specification under the guidance of project architect & Engineer in charge.
182Canteen chair : Café Chair Supplying, and placing in position of canteen chair as per image. size: (l)381mm x (d)419mm x (h)839mm.The seat and back in pvc moulded chair with ss 202 grade frameround pipe. The chair comes in various colours - green, black, red,yellow, blue, brown, orange, white.The product should be from the manufacture which have BIFMA Compliance Certification, GREENGUARD/GREENPRO/FSC Certification,AIOTA Certification and from the approved make of Durian, Godrej,HNI. The product should be as per above given specification under the guidance of project architect & Engineer in charge.
183ELECTRICAL WORKS
184MCB distribution board -240V : DISTRIBUTION BOARD Supplying and fixing following way, single pole and neutral, sheet steel, MCB distribution board, 240 V, on surface/ recess complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator)12 way, Double door
185MCB distribution board -415 V : DISTRIBUTION BOARD Supplying and fixing following way, horizontal type three pole and neutral, sheet steel, MCB distribution board, 415 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/ Isolator)8 way Double door
186Double pole 240V-63 amps : DISTRIBUTION BOARD Supplying and fixing following rating, double pole, 240 volts, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required.63 amps
187Double pole 415V-63 amps : DISTRIBUTION BOARD Supplying and fixing following rating, four pole, 415 volts, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required.63 amps
188S&F 5 amps to 32 amps rating : DISTRIBUTION BOARD Supplying and fixing 5 amps to 32 amps rating, 240/415 volts, \"C\" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required.Single pole
189RCCB - 63 amps : DISTRIBUTION BOARD Supplying and fixing following rating, double pole, single phase and neutral, 240 volts, residual current circuit breaker ( RCCB), having a sensitivity current upto 30 milliamperes in the existing MCB DB complete with connections, testing and commissioning etc as required.63 amps
190Wiring for light point etc : INTERNAL WIRINGWiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm. FR PVC insulated copper conductor single core cable etc as required.Group – C
191Wiring for grouped looped light point : INTERNAL WIRINGWiring for group controlled (looped) light point/fan point/exhaust fan point/ call bell point (without independent switch etc.) with1.5 sq. mm FRLS PVC insulated copper conductor single core cable in surface/ recessed PVC conduit, and earthing the pointwith 1.5 sq. mm FRLS PVC insulated copper conductor single core cable etc. as required.Group – C
192Wiring for circuit-2 X 1.5 sq. mm + 1 X 1.5 sq. mm earth wire : INTERNAL WIRINGWiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required2 X 1.5 sq. mm + 1 X 1.5 sq. mm earth wire
193Wiring for circuit-2 X 2.5 sq. mm + 1 X 2.5 sq. mm earth wire : INTERNAL WIRINGWiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required2 X 2.5 sq. mm + 1 X 2.5 sq. mm earth wire
194Wiring for circuit-2 X 10 sq. mm + 1 X 6 sq. mm earth wire : INTERNAL WIRINGWiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required2 X 10 sq. mm + 1 X 6 sq. mm earth wire
195Wiring for circuit-2 X 16 sq. mm + 1 X 6 sq. mm earth wire : INTERNAL WIRINGWiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required2 X 16 sq. mm + 1 X 6 sq. mm earth wire
196GI box with modular plate-3 pin 5/6 amps modular socket outlet and 5/6 amps modular switch : INTERNAL WIRINGSupplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 3 pin 5/6 amps modular socket outlet and 5/6 amps modular switch, connection etc. as required. (For light plugs to be used in residential buildings).
197GI box with modular plate-6 pin 5/6 & 15/16 amps modular socket outlet and 15/16 amps modular switch : INTERNAL WIRINGSupplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 6 pin 5/6 & 15/16 amps modular socket outlet and 15/16 amps modular switch, connection etc. as required.
198Wiring for light/ power plug with 2X4 sq. mm FRLS PVC insulated copper : INTERNAL WIRINGWiring for light/ power plug with 2X4 sq. mm FRLS PVC insulated copper conductor single core cable in surface/ recessed medium class PVC conduit alongwith 1 No 4 sq. mm FRLS PVC insulated copper conductor single core cable for loop earthing as required.Make:KEI,Worldcab,RR Kable,Bonton
199Wiring for light/ power plug with 4X4 sq. mm FRLS PVC insulated copper : INTERNAL WIRINGWiring for light/ power plug with 4X4 sq. mm FRLS PVC insulated copper conductor single core cable in surface/ recessed medium class PVC conduit alongwith 2 Nos 4 sq. mm FRLS PVC insulated copper conductor single core cable for loop earthing as required.Make:KEI,Worldcab,RR Kable,Bonton
200SITC of 4ft Linear Traiangular shaped up and down Suspended diffused LED : FANS & LIGHT FIXTURESSITC of 4ft Linear Traiangular shaped up and down Suspended diffused LED luminaire with system power 40W & 10Wdimension should not be more than 1200 x 60 x 56 mm should be available in 3000K/4000K/6000K color temperature operational voltage range of 90-265V, power factor > 0.9, THD < 10%, Inbuilt surge protection of 2.5 KV, Luminaire has Ingress protection of IP20 The luminaire should have minimum lumen outputof 3500 lumens , CRI of >80 . The LEDs used have a life of 50000 burninghrs Lumen maintenance as per L70B10 with SDCM<=3 binningLuminaire performance & Safety :IEC 60598, IS 10322-5, IS 161-03/05/06/07, Surge : IEC 61000-4-5, IES, LM 79, LM 80, & TTC certificates will be provided from NABL accredited lab.Certification: CE Certified, Design Patented/Registered, ROHS compliant, BIS Certification for Luminaires & Drivers K Lite Model KL-3434 or euivalent makePhilips/Regent/LT
201SITC of IP-44 rated round Suspended diffused LED : FANS & LIGHT FIXTURESSITC of IP-44 rated round Suspended diffused LED luminaire with system power 60W, dimension should not be more thanØ598 x 80 mm should be available in 3000K/4000K/6000K color temperature operational voltage range of 90-265V, power factor > 0.9, THD < 10%, Inbuilt surge protection of 6 KV, Luminaire has Ingress protection of IP20 The luminaire should have minimum lumen outputof 6200 lumens , CRI of >80 .It should be made from High-Grade spun alumnium with diffuser option Prismatic / Satin Acrylic The LEDs used have a life of 50000 burninghrs Lumen maintenance as per L70B10 with SDCM<=3 binning Luminaire performance & Safety :IEC 60598, IS 10322-5, IS 161-03/05/06/07, Surge : IEC 61000-4-5,IES, LM 79, LM 80, & TTC certificates will be provided from NABL accredited lab.Certification: CE Certified, Design Patented/Registered, ROHS compliant, BIS Certification for Luminaires & Drivers. K Lite Model KL-2848 or euivalent make I Philips/Regent/LT
202SITC of IP-40 rated 16W LED ceiling square : FANS & LIGHT FIXTURESSITC of IP-40 rated 16W LED ceiling square surface mounted back-lit Indoor luminaire with soft uniform Light distribution. Luminaire should be made of die-cast aluminium for better thermal management. High efficiency diffuser for glare free, uniform light distribution. CRI (Ra) : >80, SDCM= 3 to avoid color deviation , Led life should be atleast L70B10 50,000hrsHigh lumen output (Delivered) of at least 90lm/w.High PF constant current LED driver with surge and thermal protection with follwoing ratings Power Supply : Integrated Power Factor : >0.90 THD : <10% Surge Protection : 2.5KV Efficiency : >83%.Suitable for operation on 240V, 50Hz single phase ac supply, Operating Voltage : 90-265Vac Operating Temperature : -15°~+50°C CE,BIS. K Lite Model KL-7331 or euivalent makePhilips/Regent/LT
203SITC of IP-40 rated 18W LED ceiling recessed back-lit panel light : FANS & LIGHT FIXTURESSITC of IP-40 rated 18W LED ceiling recessed back-lit panel light - Indoor luminaire with soft uniform Light distribution. Luminaire should be made of die-cast aluminium for better thermal management. High efficiency diffuser for glare free, uniform light distribution. CRI (Ra) : >80, SDCM= 3 to avoid color deviation , Led life should be atleast L70B10 50,000hrsHigh lumen output (Delivered) of at least 100lm/w.High PF constant current LED driver with surge and thermal protection with follwoing ratings Power Supply : Integrated Power Factor : >0.90 THD : <20% Surge Protection : 2.5KV Efficiency : >83%.Suitable for operation on 240V, 50Hz single phase ac supply, Operating Voltage : 90-265Vac Operating Temperature : -15°~+50°C.CE,BIS. K Lite Model KL-3322 or euivalent make Philips/Regent/LT
204SITC of Wall Mounted LED fixture with system power : FANS & LIGHT FIXTURESSITC of Wall Mounted LED fixture with system power [12W± 5%] should be available in 3000K/4000K/6000K color temperature, minimum dimesnion 226 x 94 x 108mm,should be made up Luminaire made of extruded aluminium with fabricated aluminium frame, Extruded aluminium housing profile designed to throw upward and downward lighting, UGR<19, operational voltage range of 90-265V, power factor > 0.9, THD < 10%, Inbuilt surge protection of 3 KV, Luminaire has Ingress protection of IP20. The luminaire should have minimum lumen outputof 1000 lumens , CRI of >80 .The LEDs used have a life of 50000 burninghrs Lumen maintenance as per L70B10 with SDCM<=3 binning Luminaire performance & Safety :IEC 60598, IS 10322-5, IS 161-03/05/06/07, Surge : IEC 61000-4-5, IES, LM 79, LM 80, & TTC certificates will be provided from NABL accredited lab.Certification: CE Certified, Design Patented/Registered, ROHS compliant, BIS Certification for Luminaires & Drivers. K-Lite ModelKL-3778or euivalent makePhilips/Regent/LT
205Fresh air exhaust : FANS & LIGHT FIXTURESSITC Fresh air exaust fan 300 mm
206Laying of one number PVC insulated and PVC sheathed Upto 35 sq. mm : CABLE & END TEMINATIONSLaying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size direct in ground including excavation, sand cushioning, protective covering and refilling the trench etc as required.Upto 35 sq. mm
207PVC sheathed / XLPE power cable in RCC/HUME/METAL : CABLE & END TEMINATIONSLaying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size in the existing RCC/ HUME/ METAL pipe as required.Upto 35 sq. mm
208PVC sheathed / XLPE power cable in existing masonary : CABLE & END TEMINATIONSLaying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size in the existing masonry open duct as required.Upto 35 sq. mm
209PVC sheathed / XLPE power cable on cable tray : CABLE & END TEMINATIONSLaying and fixing of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size on cable tray as required.Upto 35 sq. mm (clamped with 1mm thick saddle)
210Cable route marker : CABLE & END TERMINATIONSSupplying and fixing cable route marker with 10 cm X 10 cm X 5 mm thick G.I. plate with inscription there on, bolted /welded to 35 mm X 35 mm X 6 mm angle iron, 60 cm long and fixing the same in ground as required.
211Supplying and making end termination-2 X 6 sq. mm (19mm) : CABLE END TERMINATIONSSupplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required. 2 X 6 sq. mm (19mm)
212Supplying and making end termination-4 X 10 sq. mm (25mm): CABLE END TERMINATIONSSupplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.4 X 10 sq. mm (25mm)
213Supplying and making end termination-4 X 16 sq. mm (28mm): CABLE END TERMINATIONSSupplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.4 X 16 sq. mm (28mm)
214Supplying and making end termination-4 X 25 sq. mm (28mm): CABLE END TERMINATIONSSupplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.4 X 25 sq. mm (28mm)
215Cable trays- 100 mm width X 50 mm depth X 1.6mm thickness : CABLE TRAYSupplying and installing following size of perforated pre-painted M.S cable trays reducers with perforation not more than 17.5%, inconvenient sections, joined with connectors, suspended from the ceiling with M.S. suspenders including bolts&nuts, painting suspenders etc as required.100 mm width X 50 mm depth X 1.6mm thickness
216Cable trays- 150 mm width X 50 mm depth X 1.6mm thickness : CABLE TRAYSupplying and installing following size of perforated pre-painted M.S cable trays reducers with perforation not more than 17.5%, inconvenient sections, joined with connectors, suspended from the ceiling with M.S. suspenders including bolts&nuts, painting suspenders etc as required.150 mm width X 50 mm depth X 1.6mm thickness
217Cable trays- 300 mm width X 50 mm depth X 1.6mm thickness : CABLE TRAYSupplying and installing following size of perforated pre-painted M.S cable trays reducers with perforation not more than 17.5%, inconvenient sections, joined with connectors, suspended from the ceiling with M.S. suspenders including bolts&nuts, painting suspenders etc as required.300 mm width X 50 mm depth X 1.6mm thickness
218HVAC WORKS
219Variable refrigerant Volume system : MACHINERYVariable Refrigerant VolumeSystemSupply Installation, Testing & Commissioning of modular type Variable Refrigerant Flow/Variable Refrigerant Volume air cooled Outdoor units suitable for cooling, having all hermetically sealed inverter type Scroll Compressor(s), minimum two compressors for above 14 HP modules, microprocessor based Controller, top discharge type condensing unit(s), with R 410 A Refrigerant, vibration isolators, with suitable foundation etc. complete as required. The unit shall deliver the rated capacity at AHRI Conditions and work even at 50°C ambient temperature without tripping. The unit shall be suitable to work on 400V +/- 10%, 3 Phase, 50Hz AC power supply. The unit shall be filled with first charge of the refrigerant and ready for use as required. The COP at AHRI conditions shall not be less than 3.1 and IEER not less than 6.5.Makes: Hitachi/LG/Daikin/Trane/Toshiba/ Mitshibushi OutdoorVRV Unit capacity 18 HP
220INDOOR UNIT-CASSETTE TYPE-2.5 TR : INDOOR UNIT-CASSETTE TYPESupply, installation, testing and commissioning of following minimum capacity 4-way flow VRV/VRF Cassette Type Indoor ceiling mounted unit equipped with synthetic washable media pre-filter, fan section with low noise fan/dynamically balanced blower, multispeed motor, coil section with DX Copper coil, electronic expansion valve, outer cabinet, drain pump, grill, necessary supports, vibration isolation, cord less remote control etc., suitable for operation on single phase 230 V ± 10%, 50Hz AC supply, complete, as required. The unit shall have automatic force shut down provision in case of fire on receiving signal from BMS System. The cooling capacity of indoor unit will be at air inlet conditions of 27 Degree C DB and 19 Degree C WB temperature.Makes: Hitachi/LG/Daikin/Trane/Toshiba/ Mitshibushi 2.5 TR
221INDOOR UNIT-CASSETTE TYPE-3.18 TR : INDOOR UNIT-CASSETTE TYPESupply, installation, testing and commissioning of following minimum capacity 4-way flow VRV/VRF Cassette Type Indoor ceiling mounted unit equipped with synthetic washable media pre-filter, fan section with low noise fan/dynamically balanced blower, multispeed motor, coil section with DX Copper coil, electronic expansion valve, outer cabinet, drain pump, grill, necessary supports, vibration isolation, cord less remote control etc., suitable for operation on single phase 230 V ± 10%, 50Hz AC supply, complete, as required. The unit shall have automatic force shut down provision in case of fire on receiving signal from BMS System. The cooling capacity of indoor unit will be at air inlet conditions of 27 Degree C DB and 19 Degree C WB temperature.Makes: Hitachi/LG/Daikin/Trane/Toshiba/ Mitshibushi 3.18 TR
222VRV/VRF ductable Type Indoor : INDOOR UNIT-CASSETTE TYPESupply, installation, testing and commissioning of following minimum capacity VRV/VRF ductable Type Indoor ceiling mounted unit equipped with synthetic washable media pre-filter, fan section with low noise fan/dynamically balanced blower, multispeed motor, coil section with DX Copper coil, electronic expansion valve, outer cabinet, drain pump, grill, necessary supports, vibration isolation, cord less remote control etc., suitable for operation on single phase 230 V ± 10%, 50Hz AC supply, complete, as required. The unit shall have automatic force shut down provision in case of fire on receiving signal from BMS System. The cooling capacity of indoor unit will be at air inlet conditions of 27 Degree C DB and 19 Degree C WB temperature.Makes: Hitachi/LG/Daikin/Trane/Toshiba/ Mitshibushi 600 cfm, Treated Fresh Air Unit
223Y joints : INDOOR UNIT-CASSETTE TYPESupply Installation, Testing and commissioning of Imported fittings (Ref Net) Y-joints etc.Makes:Hitachi/LG/Daikin/Trane/Toshiba/ Mitshibushi
224Corded remote controls : INDOOR UNIT-CASSETTE TYPESupply Installation, Testing and commissioning of Corded remote controls with holder etc. As required.Makes: Hitachi/LG/Daikin/Trane/Toshiba/ Mitshibushi
225Copper Refrigerant Piping-6.4 mm dia : PIPING & INSULATIONCopper Refrigerant PipingSupply, Installation, testing and commissioning including vaccumiazation and Nitrogen testing of following nominal sizes of soft/hard drawn copper refrigerant piping for VRV/VRF system, complete with fittings, with suitable adjustable ring type hanger supports, jointing/brazing including accessories, insulated with XPLE Class-O tubular insulation/with Class-O closed cell elastometric nitrile rubber tubular sleeves sections of specified thickness as given below for Suction and Liquid lines, all accessories as per specifications etc. as required : 6.4 mm dia (OD) (Soft drawn) with tube thickness 1.2 mm with 19 mm thick insulationNOTE:- (1) The Copper Piping & Piping Circuit should be with Minimum Number of joints, which shall be attained by :(i) Using One End Expanded Tubes (ii) Bending the tubes instead of using elbow joints wherever 90 degree bending is required. (2) Piping should be routed at site in such a manner, that brazed joints in the refrigeration piping are kept to a minimuM(3) The makes of tube fittings shall be same as that of tubes.(4) The thickness of fittings used shall be same as that of the pipe.Makes of Copper Pipe: Mandev/Rajco/MaxflowMakes of XLPE Insulation: CANI/TheMobreak/k-flex/a-flex
226Copper Refrigerant Piping-9.5 mm dia : PIPING & INSULATIONCopper Refrigerant PipingSupply, Installation, testing and commissioning including vaccumiazation and Nitrogen testing of following nominal sizes of soft/hard drawn copper refrigerant piping for VRV/VRF system, complete with fittings, with suitable adjustable ring type hanger supports, jointing/brazing including accessories, insulated with XPLE Class-O tubular insulation/with Class-O closed cell elastometric nitrile rubber tubular sleeves sections of specified thickness as given below for Suction and Liquid lines, all accessories as per specifications etc. as required : 9.5 mm dia (OD) (Soft drawn) with tube thickness 1.2 mm with 19 mm thick insulationNOTE:- (1) The Copper Piping & Piping Circuit should be with Minimum Number of joints, which shall be attained by :(i) Using One End Expanded Tubes (ii) Bending the tubes instead of using elbow joints wherever 90 degree bending is required. (2) Piping should be routed at site in such a manner, that brazed joints in the refrigeration piping are kept to a minimuM(3) The makes of tube fittings shall be same as that of tubes.(4) The thickness of fittings used shall be same as that of the pipe.Makes of Copper Pipe: Mandev/Rajco/MaxflowMakes of XLPE Insulation: CANI/TheMobreak/k-flex/a-flex
227Copper Refrigerant Piping-12.7mm dia : PIPING & INSULATIONCopper Refrigerant PipingSupply, Installation, testing and commissioning including vaccumiazation and Nitrogen testing of following nominal sizes of soft/hard drawn copper refrigerant piping for VRV/VRF system, complete with fittings, with suitable adjustable ring type hanger supports, jointing/brazing including accessories, insulated with XPLE Class-O tubular insulation/with Class-O closed cell elastometric nitrile rubber tubular sleeves sections of specified thickness as given below for Suction and Liquid lines, all accessories as per specifications etc. as required : 12.7 mm dia (OD) (Soft drawn) with tube thickness 1.2 mm with 19 mm thick insulationNOTE:- (1) The Copper Piping & Piping Circuit should be with Minimum Number of joints, which shall be attained by :(i) Using One End Expanded Tubes (ii) Bending the tubes instead of using elbow joints wherever 90 degree bending is required. (2) Piping should be routed at site in such a manner, that brazed joints in the refrigeration piping are kept to a minimuM(3) The makes of tube fittings shall be same as that of tubes.(4) The thickness of fittings used shall be same as that of the pipe.Makes of Copper Pipe: Mandev/Rajco/MaxflowMakes of XLPE Insulation: CANI/TheMobreak/k-flex/a-flex
228Copper Refrigerant Piping-15.8mm dia : PIPING & INSULATIONCopper Refrigerant PipingSupply, Installation, testing and commissioning including vaccumiazation and Nitrogen testing of following nominal sizes of soft/hard drawn copper refrigerant piping for VRV/VRF system, complete with fittings, with suitable adjustable ring type hanger supports, jointing/brazing including accessories, insulated with XPLE Class-O tubular insulation/with Class-O closed cell elastometric nitrile rubber tubular sleeves sections of specified thickness as given below for Suction and Liquid lines, all accessories as per specifications etc. as required : 15.86 mm dia (OD) (Soft drawn) with tube thickness 1.2 mm with 19 mm thick insulation NOTE:- (1) The Copper Piping & Piping Circuit should be with Minimum Number of joints, which shall be attained by :(i) Using One End Expanded Tubes (ii) Bending the tubes instead of using elbow joints wherever 90 degree bending is required. (2) Piping should be routed at site in such a manner, that brazed joints in the refrigeration piping are kept to a minimuM(3) The makes of tube fittings shall be same as that of tubes.(4) The thickness of fittings used shall be same as that of the pipe.
229Copper Refrigerant Piping-19 mm dia : PIPING & INSULATIONCopper Refrigerant PipingSupply, Installation, testing and commissioning including vaccumiazation and Nitrogen testing of following nominal sizes of soft/hard drawn copper refrigerant piping for VRV/VRF system, complete with fittings, with suitable adjustable ring type hanger supports, jointing/brazing including accessories, insulated with XPLE Class-O tubular insulation/with Class-O closed cell elastometric nitrile rubber tubular sleeves sections of specified thickness as given below for Suction and Liquid lines, all accessories as per specifications etc. as required : 19 mm dia (OD) (Hard drawn) with tube thickness 1.2 mm with 19 mmthick insulationNOTE:- (1) The Copper Piping & Piping Circuit should be with Minimum Number of joints, which shall be attained by :(i) Using One End Expanded Tubes (ii) Bending the tubes instead of using elbow joints wherever 90 degree bending is required. (2) Piping should be routed at site in such a manner, that brazed joints in the refrigeration piping are kept to a minimuM(3) The makes of tube fittings shall be same as that of tubes.(4) The thickness of fittings used shall be same as that of the pipe.
230Copper Refrigerant Piping-22.2 mm dia : PIPING & INSULATIONCopper Refrigerant PipingSupply, Installation, testing and commissioning including vaccumiazation and Nitrogen testing of following nominal sizes of soft/hard drawn copper refrigerant piping for VRV/VRF system, complete with fittings, with suitable adjustable ring type hanger supports, jointing/brazing including accessories, insulated with XPLE Class-O tubular insulation/with Class-O closed cell elastometric nitrile rubber tubular sleeves sections of specified thickness as given below for Suction and Liquid lines, all accessories as per specifications etc. as required : 22.2 mm dia (OD) (Hard drawn) with tube thickness 1.2 mm with 19 mm thick insulationNOTE:- (1) The Copper Piping & Piping Circuit should be with Minimum Number of joints, which shall be attained by :(i) Using One End Expanded Tubes (ii) Bending the tubes instead of using elbow joints wherever 90 degree bending is required. (2) Piping should be routed at site in such a manner, that brazed joints in the refrigeration piping are kept to a minimuM(3) The makes of tube fittings shall be same as that of tubes.(4) The thickness of fittings used shall be same as that of the pipe.Makes of Copper Pipe: Mandev/Rajco/MaxflowMakes of XLPE Insulation: CANI/TheMobreak/k-flex/a-flex
231Copper Refrigerant Piping-28.58 mm dia : PIPING & INSULATIONCopper Refrigerant PipingSupply, Installation, testing and commissioning including vaccumiazation and Nitrogen testing of following nominal sizes of soft/hard drawn copper refrigerant piping for VRV/VRF system, complete with fittings, with suitable adjustable ring type hanger supports, jointing/brazing including accessories, insulated with XPLE Class-O tubular insulation/with Class-O closed cell elastometric nitrile rubber tubular sleeves sections of specified thickness as given below for Suction and Liquid lines, all accessories as per specifications etc. as required : 28.58 mm dia (OD) (Hard drawn) with tube thickness 1.2 mm with 19 mm thick insulationNOTE:- (1) The Copper Piping & Piping Circuit should be with Minimum Number of joints, which shall be attained by :(i) Using One End Expanded Tubes (ii) Bending the tubes instead of using elbow joints wherever 90 degree bending is required. (2) Piping should be routed at site in such a manner, that brazed joints in the refrigeration piping are kept to a minimuM(3) The makes of tube fittings shall be same as that of tubes.(4) The thickness of fittings used shall be same as that of the pipe.Makes of Copper Pipe: Mandev/Rajco/MaxflowMakes of XLPE Insulation: CANI/TheMobreak/k-flex/a-flex
232Copper Refrigerant Piping-34.9 mm dia : PIPING & INSULATIONCopper Refrigerant PipingSupply, Installation, testing and commissioning including vaccumiazation and Nitrogen testing of following nominal sizes of soft/hard drawn copper refrigerant piping for VRV/VRF system, complete with fittings, with suitable adjustable ring type hanger supports, jointing/brazing including accessories, insulated with XPLE Class-O tubular insulation/with Class-O closed cell elastometric nitrile rubber tubular sleeves sections of specified thickness as given below for Suction and Liquid lines, all accessories as per specifications etc. as required : 34.9 mm dia (OD) (Hard drawn) with tube thickness 1.62 mm with 19 mm thick insulationNOTE:- (1) The Copper Piping & Piping Circuit should be with Minimum Number of joints, which shall be attained by :(i) Using One End Expanded Tubes (ii) Bending the tubes instead of using elbow joints wherever 90 degree bending is required. (2) Piping should be routed at site in such a manner, that brazed joints in the refrigeration piping are kept to a minimuM(3) The makes of tube fittings shall be same as that of tubes.(4) The thickness of fittings used shall be same as that of the pipe.Makes of Copper Pipe: Mandev/Rajco/MaxflowMakes of XLPE Insulation: CANI/TheMobreak/k-flex/a-flex
233Copper Refrigerant Piping-41.27mm dia : PIPING & INSULATIONCopper Refrigerant PipingSupply, Installation, testing and commissioning including vaccumiazation and Nitrogen testing of following nominal sizes of soft/hard drawn copper refrigerant piping for VRV/VRF system, complete with fittings, with suitable adjustable ring type hanger supports, jointing/brazing including accessories, insulated with XPLE Class-O tubular insulation/with Class-O closed cell elastometric nitrile rubber tubular sleeves sections of specified thickness as given below for Suction and Liquid lines, all accessories as per specifications etc. as required : 41.27 mm dia (OD) (Hard drawn) with tube thickness 1.62 mm with 19 mm thick insulation NOTE:- (1) The Copper Piping & Piping Circuit should be with Minimum Number of joints, which shall be attained by :(i) Using One End Expanded Tubes (ii) Bending the tubes instead of using elbow joints wherever 90 degree bending is required. (2) Piping should be routed at site in such a manner, that brazed joints in the refrigeration piping are kept to a minimuM(3) The makes of tube fittings shall be same as that of tubes.(4) The thickness of fittings used shall be same as that of the pipe.Makes of Copper Pipe: Mandev/Rajco/MaxflowMakes of XLPE Insulation: CANI/TheMobreak/k-flex/a-flex
234PVC drain piping-20mm dia : PVC Drain PipingSupply, Installation, testing and commissioning of PVC Drain piping complete with 6mm XLPE Class O insulatiuon, fittings, supports accessories in surface/recess as perspecifications & site requiMents20 mm diaMakes: Supreme/Astral/AKG
235PVC drain piping-25mm dia : PVC Drain PipingSupply, Installation, testing and commissioning of PVC Drain piping complete with 6mm XLPE Class O insulatiuon, fittings, supports accessories in surface/recess as per specifications & site requiMents25 mm diaMakes: Supreme/Astral/AKG
236PVC drain piping-32mm dia : PVC Drain PipingSupply, Installation, testing and commissioning of PVC Drain piping complete with 6mm XLPE Class O insulatiuon, fittings, supports accessories in surface/recess as per specifications & site requiMents32 mm diaMakes: Supreme/Astral/AKG
237Factory fabricated GSS sheet metal : AIR DISTRIBUTIONFactory Fabricated DuctSupply, installation, balancing and commissioning of factory fabricated GSS sheet metal rectangular/round ducting complete with neoprene rubber gaskets, elbows, splitter dampers, vanes, hangers, supports etc. as per approved drawings and specifications of following sheet thickness complete as required.Thickness 0.63 mm sheet
238External thermal insulation on ducts : Duct InsulationSupplying , installation, testing & commissioning of external thermal insulation on ducts with Duly laminated aluminum foilof mat finish Closed Cell Cross Linked Polyethylene (class “O”) insulation shall be 27 ± 3 Kg/m3. The product shall have temperature range of –40 oC to 105oC. Thermal Conductive not exceeding 0.033 W/mK at an average Temperature of 23°C. The insulation material shall be fire rated for Class 1 as per BS 476 Part 6 : 1989 for fire propagation test and for Class 0 as per BS 476 Part 7, 1987 for surface spread of flame test. Water vapour permeability shall be not less than 0.024 per inch (2.48 x 10-14 Kg/m.s.Pa i.e. µ>7000: Water vapour diffusion resistance).The Material shall have Fire Approval from CBRI - Roorkie19 mm thick Closed Cell Cross Linked Polyethylene( XLPE) Foam with Factory Laminated Aluminium Foil for Supply Air Duct
239GI Duct Damper : GI Duct DamperSupply, installation, testing and commissioning of GI volume control duct damper complete with neoprene rubber gaskets, nuts, bolts, screws linkages, flanges etc, as per specifications.Make: Airflow/System Air/Caryaire/Cynor
240PVCinsulatedand PVC sheathed, flexible, Copper Conductor: ELECTRICAL SYSTEMFLEXIBLE CONTROL CABLINGSupply, laying, testing and commissioning ofPVCinsulatedand PVC sheathed, flexible, Copper Conductorof 1.1 KV grade on existing cable trays asper standard specification including end teMination as required.2C x 1.0 Sq mmMakes:Polycab/Skytone/Havells
241Perforated Hot Dipped Galvanised Iron cable tray : Cable Trays Supplying and installing following size of perforated Hot Dipped Galvanised Iron cable tray (Galvanisation thickness not less than 50 microns) with perforation not more than 17.5%, in convenient sections, joined with connectors, suspended from the ceiling with G.I. suspenders including G.I. bolts & nuts, etc. as required.150 mm width X 50 mm depth X 1.6 mm thicknessMakes: Rico/Slotco/Pilco
242Earthing 25mm*5mm GI strip : EARTHING:Providing and fixing 25 mm X 5 mm G.I. strip on surface or in recess for connections etc. as required.
2436 SWG dia G.I. wire : EARTHING:Providing and fixing 6 SWG dia G.I. wire on surface or in recess for loop earthing as required.
244Isolator suitable for 18 HP outdoor unit : Supply installation testing & commissioning of Isolator suitable for 18 HP outdoor unit, complete with wire and other acceossries which required to switch on & off the unit.

AI Tender Summary

OUR REF NO 39031140
AUTHORITY Boards / Undertakings / PSU
TENDER VALUE Ref. Documents
LAST DATE 31-08-2023
Authority
Authority Name Gas Authority Of India Limited
Work Description Tender For Renovation And Extension Of Canteen In Technical Building At Gail Vijaipur
Basic Detail
Tender No GAIL/VH/C23105/NR/CIVIL/2023
Bidding Type Tender
Location
City vijaipur
State Madhya Pradesh
Key Dates
Publish Date 07 Aug 2023
Submission Date 31 Aug 2023
Open Date 01 Sep 2023
Finance
Tender Value Ref. Documents
Tender Fee Ref. Documents
EMD 63730
Exemption Not Available
Document List
BOQ_178998.xls
Interior_Drawing.pdf
Structural_Drawing.pdf
Tender.pdf
Tendernotice_1.pdf
2960e6dc-14af-4b5c-be76-01a2685ed8c6.html

Unlock Full AI Tender Summary

Get instant access to the complete AI-generated analysis — scope, eligibility, timeline & more.

Instant Access Secure Free
Your details are secure and used only for document delivery.

Tender Timeline

Aug 07, 2023
11:30 IST

Tender Published

Tender notice published.

Completed
Aug 31, 2023
17:00 IST

Bid Submission Deadline

Online submission via eProcurement portal.

Completed
Sep 01, 2023

Bid Opening Date

Technical bids will be opened and evaluated.

Completed

Tender Documents

Download All (ZIP) ↓
xls

BOQ_178998.xls

pdf

Interior_Drawing.pdf

pdf

Structural_Drawing.pdf

pdf

Tender.pdf

pdf

Tendernotice_1.pdf

html

2960e6dc-14af-4b5c-be76-01a2685ed8c6.html