Tender For Provision Additional /Alternator Of Perimeter Security Wall With Guard Posts, Guard Rest Room And Security Lights At Certain Locations At Af Station Awantipur., Pulwama-Jammu And Kashmir

Military Engineer Services-MES has published Tender For Provision Additional /Alternator Of Perimeter Security Wall With Guard Posts, Guard Rest Room And Security Lights At Certain Locations At Af Station Awantipur.. Submission Date for this Tender is 13-11-2023. Wall construction Tenders in Pulwama Jammu And Kashmir. Bidders can get complete Tender details and download the document.




Tender Notice

39028320
Corrigendum : Tender For Provision Additional /Alternator Of Perimeter Security Wall With Guard Posts, Guard Rest Room And Security Lights At Certain Locations At Af Station Awantipur.
Open Tender
Indian
Jammu And Kashmir
Pulwama
13-11-2023

Tender Details

Tender For Provision Additional /Alternator Of Perimeter Security Wall With Guard Posts, Guard Rest Room And Security Lights At Certain Locations At Af Station Awantipur.

Corrigendum Details

Sr No CorrigendumDate Corrignedum CorrigendumType NewSubmissionDate
1 04-Sep-2023 Date Corrigendum 01 Date 25-09-2023
2 18-Sep-2023 Date Corrigendum 02 Date 10-10-2023
3 03-Oct-2023 Date Corrigendum 03 Date 24-10-2023
4 17-Oct-2023 Date Corridendum 04 Date 31-10-2023
5 23-Oct-2023 Other Corrigendum 01 Other 06-11-2023
6 23-Oct-2023 Date Corrigendum 05 Date 06-11-2023
7 23-Oct-2023 BOQ Corrigendum 01 BOQ 06-11-2023
8 25-Oct-2023 Other Corrigendum 02 Other 06-11-2023
9 06-Nov-2023 Bid Auto Extn Corrigendum Bid Auto Extn Corrigendum 13-11-2023

Key Value

Document Fees
INR 3000 /-
EMD
INR 627000.0 /-
Tender Value
INR 6.03 Crore /-

BOQ Items

Name of Work:PROVN/ADDN/ALT OF PERIMETER SECURITY WALL WITH GUARD POSTS, GUARD REST ROOM AND SECURITY LIGHTS AT CERTAIN LOCATIONS AT AF STN AWANTIPUR.
Sl. No. Item Description
1SCHEDULE `A" PART-I (BUILDING WORK) Note : This schedule is not pre priced by MES and the pre priced rate indicated as "Rs. 0.00" under Col.5 signifies this fact only.
2Block of watch tower of size 2.56 m x 4.71 m triple storey, RCC framed construction, Galvalume sheet roofing with permanent complete all as specified and as shown in drawings.
3Block of watch tower with guard rest room for 03 persons of size 9.67 m X 4.71 m triple storey, RCC framed construction, Galvalume sheet roofing with permanent specifications complete all as specified and as shown in drawings.
4Block ofguard rest room for 03 persons of size 7.34 m X 4.71 m single storey, RCC framed construction, Galvalume sheet roofing with permanent specifications complete all as specified and as shown in drawings.
5Block of guard rest room for 06 persons of size 11.00 m X 6.69 m single storey, RCC framed construction, Galvalume sheet roofing with permanent specifications complete all as specified and as shown in drawings
6Block of Sentry Postof size 2.14 X 2.14 m, single storey, framed structure, RCC roof withincluding joinery etc with permanent specifications complete all as specified and as shown in drawings
7Total amount ofSchedule "A" PART-I (BUILDING WORK)
8Total amount ofSch "A" PART-II (Sec-I) (INTERNAL ELECTRIC SUPPLY WORKS)
9SCHEDULE `A" PART-II (Sec-II) (INTERNAL ELECTRIC SUPPLY WORKS) Note : This schedule is not pre priced by MES and the pre priced rate indicated as "Rs. 0.00" under Col.5 signifies this fact only.
10Supply and fixing switch piano flush type (ISI marked), single pole, two way, 5 Amp, 240 Volts complete all as specified and directed.
11S & F LED batten surface / wall mountedwith specially designed powder coatedaluminium housing, high optically efficient polycarbonate diffuser, in built electronic driver duly wired up to terminal block, power consumption <20W, luminaire lumen >2000 lm, system efficiency of > 120 lumens/W, LED Make: Nichia/ Cree/ Everlite / Eclison/ Osram/ Lumiled, with LED binning as per ANSI Bin C78.377A, photo biological safety report as per IEC624718 & electrical insulation class 1, Ingress protection IP 20, colour rendering index CRI>80, temp range 0 to 450C, driver efficiency>85%, power factor > 0.9, THD <20% as per IEC 61000-3-2, colour temp -6500K, surge protection 2.5 KV, 50,000 burning hrs (min) as per L7O criteria, two stages isolatedconstant current operateddriverwith range 150-270V AC and safety extra low voltagesafe level < 60 V DC asper IEC standard with LM70 & LM 80 certification all as specified and directed.
12Supply and fixing LED Flood light watt,120 watt for opearting voltage between 110V to 320V system efficiency not less than 120 lumen / watt, PF-0.95 minimum, IP66 protection, 5700CCT(K),CRI between 80-85, conforming to LM79 and LM 80 standards or as per IS-16104: 2012 and IS-16106: 2012, for estimated life span ofminimum 50,000 hrs consisting of high / low voltage cut off, maintenance free isolated Electronic driver circuits, Low THD, PMMA grade high quality Transmittance lens, Epoxy powder coated Die Cast Aluminium housing with LED street optics LENS for uniform light distribution,weather proof gasket for lamp & driver compartment, Heat resistance toughened UV stabilized glass fitted in cast aluminium housing with SS screws with IP 65/66 protection, complete all as specified and as directed.
13Supply and Fixing Bracket made out of GI light grade pipe of size 40 mm dia 1.5 mtr long bend to an angle of 120 degree with 02 Nos MS clamp 50mm x 50mm and 04 sets of nuts,bolts and washers painting with two coats of synthetic enamel paint over a red oxide primer complete all as specifiedand as directed.
14S & F LED mirror light fitting /fixture surface / wall mounted with specially premium quality material with integrated LED designed powder coated aluminium housing, high optically efficient polycarbonate diffuser, in built electronic driver duly wired up to terminal block, power consumption <12W, lifetime upto 2500 hours with IP -20 class II protection 220-240 volts with total lumen ficture output of 420 with diffusing light effect with stylish heritage type looks and finish all as specified and directed.
15Supply and fixing Exhaust fan 230/250mm sweep, heavy duty motor with double ball bearing, metallic body, With bird guard to protect the fan in running condition, AC, single phase, 230 Volts, including connection with 1.5 sqmm mutistrand copper conductor flexiblewire from ceiling rose, including outside louvers with proper hole, and necessary fixing arrangment and making good to disturbed surface complete all as specified and as directed.
16Supply and fixing Sheet metal enclosure MCB distribution board single pole & neutral 240 volts 6 way with IP-43 IK-09 protection double door complete with appropriate size 200 amps bus bar and neutral link, fixed flush in wall including chases wall for fixing DB and making good distributed wall surfaces to match with existing specification complete all as specified and as directed.
17Earthing complete with galvanized steel earth plate electrode 60 cm x 60 cm x 6.0mm thick buried directly in ground, (Earth pit not less than 2.25 mtr deep below ground level) with top edge of plate not less than 1.5 mtr below normal ground level, connected to and including 4 mm dia galvanized earth lead wire by means of bolts, nuts, check nuts and washers of galvanized standard iron or steel all as specified or indicated in electrical plate No 3 of MES Part-I, including testing on completion including the material and labour of the following: - (a) Excavation and earth work or drilling hole for electrode in any type of soil. (b) PCC pit in cement concrete 1:2:4 type B-1. (c) Precast RCC cover with suitable handle 40 mm thick in PCC 1:2:4 type B-1, reinforced with welded steel wire fabric weighing not less than 1.87 Kg/Sqm. (d) Funnel with watering pipe of GI 20 mm nominal bore medium grade and copper lugs etc all as specified. (e) 15 mm nominal bore light grade GI protection pipe 5 mtr long for protection of earthing lead from mechanical injury or tempering. (f) Requisite quantity of common salt and charcoal. (g) Testing of earthing. Note: (1) The earth resistance shall be less than 1 ohms after completion of earthing. If the desired earth resistance is not obtained, the earthing shall be re-done by the contractor at his own risk and cost to the entire satisfaction of the Engineer-in-Charge.
18Total amount ofSch "A" PART-II (Section-II) (INTERNAL ELECTRIC SUPPLY WORK)
19Total amount ofSch "A" PART-III (Section-I) (INTERNAL WATER SUPPLY WORK)
20SCHEDULE `A" PART-III (SECTION-II) (INTERNAL WATER SUPPLY WORK) Note : This schedule is not pre priced by MES and the pre priced rate indicated as "Rs. 0.00" under Col.5 signifies this fact only.
21S&F C P health Faucets with flexible tube 15mm dia for EWC including all connection complete and all as specified by Engineer-in-Charge.
22Total amount ofSch "A" PART-III (Section-II) (INTERNAL WATER SUPPLY WORK)
23Total amount ofSch "A" PART-IV (PLUMBING WORK)
24Total amount ofSch "A" PART-V (HOT WATER SUPPLY WORK)
25Total amount ofSch "A" PART-VI (CIVIL WORK FOR VIEW CUTTER WORK)
26Total amount ofSch "A" PART-VII (PATH WORKS)
27Total amount ofSch "A" PART-VIII (SEC-I) (SEWAGE DISPOSAL WORK)
28Sch "A" PART-VIII (SEC-II)(SEWAGE DISPOSAL WORK) Note: This schedule is not pre priced by MES and the pre priced rate indicated as "Rs. 0.00" under Col.5 signifies this fact only.
29Supply and fixing of LLDPE tank for 10 users including vent shaft and other necessary fixing arrangment including necessory excavation, earth work and other civil works ar per manufacturer"s recommendation complete all as specified and as directed Make- Sintex, Code No. PWTS-AM-300-01 or equal approved Make of Comfert polymers or Polycon
30Total amount ofSch "A" PART-VIII (SEC-II)(SEWAGE DISPOSAL WORK)
31Total amount ofSch "A" Part-IX(GATE WORK)
32Total amount ofSch "A" PART-X (Section-I) (EXTERNAL WATER SUPPLY WORK)
33Sch "A" Part-X (Section-II) (EXTERNAL WATER SUPPLY WORK) Note : This schedule is not pre priced by MES and the pre priced rate indicated as "Rs. 0.00" under Col.5 signifies this fact only.
34Material and labour for construction of valve chamber of size600x 600 x 600 mm deepdimensions (Over all internal dimension) for control valve etc. with PCC foundation, PCC block masonry walls, Plastering, PCC Coping, white washing, mild steel chamber cover, painting to chamber cover including Excavation and earth work in any type of soil complete all as specified below:- Valve chamber shall be provided with the following specifications:- (i) Cement concretefor foundation (1:4:8) type D2 using 40mm graded stone aggregate 150 mm thickextended up to 150 mm beyond the outer face of block masonry. (ii) Walls of valve chamber 200 mm thick with precast cement concrete (1:5:8) (using 20mm graded stone aggregate) solid building blocks , setting in CM 1:6 complete.(iii) Internal and exposed surfaces of valve chamber both concrete and block masonry surface shall be plastered with CM (1:4), 15 mm thick finished even and smooth. (iv)50 mm thick coping in PCC 1:3:6 type C1 over block masonry wall. (v) Entire plastered surfaces shall be treated with 3 coat of white wash. (vi) Chamber cover shall be of 3 mmthick MS sheet with 40 x 40 x 6 mm size angle iron frame with hold fast and locking arrangement including handle. Steel surface shall be painted withtwo coats of synthetic paint of first quality over one coat of red oxide primer.
35Material and labour for cutting of water supply mains, GI 80mm dia for alterations or additions and reducing to required length before laying, Screwing existing steel tubing including supply and insertion of new tee of size 80 x 80 x 40mm or as per site requirement, for branch connection complete all as specified and as directed
36Material and labour for cutting of water supply mains, GI 80mm dia for alterations or additions and reducing to required length before laying, Screwing existing steel tubing including supply and insertion of new tee of size 80 x 80 x 25mm or as per site requirement, for branch connection complete all as specified and as directed
37Total amount ofSch "A" PART-X (Section-II) (EXTERNAL WATER SUPPLY WORK)
38Total amount ofSch "A" -XI (Section-I) (EXTERNAL ELECTRIFICATION WORK)
39Sch "A" Part-XI (Section-II) (EXTERNAL ELECTRIFICATION WORK) Note : This schedule is not pre priced by MES and the pre priced rate indicated as "Rs. 0.00" under Col.5 signifies this fact only.
40Earthing complete with galvanized steel earth plate electrode 60 cm x 60 cm x 6.0mm thick buried directly in ground, (Earth pit not less than 2.25 mtr deep below ground level) with top edge of plate not less than 1.5 mtr below normal ground level, connected to and including 25 x 4mm GI strip as earth lead burried into ground and connected by means of bolts, nuts, check nuts and washers of galvanized standard iron or steel all as specified or indicated in electrical plate No 3 of MES Part-I, including testing on completion including the material and labour of the following: - (a) Excavation and earth work or drilling hole for electrode in any type of soil. (b) PCC pit in cement concrete 1:2:4 type B-1. (c) Precast RCC cover with suitable handle 40 mm thick in PCC 1:2:4 type B-1, reinforced with welded steel wire fabric weighing not less than 1.87 Kg/Sqm. (d) Funnel with watering pipe of GI 20 mm nominal bore medium grade and copper lugs etc all as specified. (e) 40 mm nominal bore light grade GI protection pipe 5 mtr long for protection of earthing lead from mechanical injury or tempering. (f) Requisite quantity of common salt and charcoal. (g) Testing of earthing. Note: (1) The earth resistance shall be less than 1 ohms after completion of earthing. If the desired earth resistance is not obtained, the earthing will be re-done by the contractor at his own risk and cost to the entire satisfaction of the Engineer-in-Charge.
41Material and labour for Boring of holes not less than 200mm dia under taxi track/road pavement hard standing or in any strata of soil by trenchless technology using ultra sounding latset technique and necessary machinery including provision of HDPE pipe 150mm dia PN 10 up to full length of bore,making good the disturbed surface using PCC work as per site requirement and returning/ refilling of excavated material and removal of surplus soil from site complete all as specified and as directed.
42Supply and fixing LEDfllood Light fitting 120 watt, for opearting voltage between 140V to 300V system efficiency not less than 120 lumen / watt,PF-0.95 minimum, IP66 protection, 5700CCT(K),CRI between 80-85,confirming to LM79 and LM 80 standards or as per IS-16104:2012 and IS-16106:2012,for estimated life span ofminimum 50,000 hrs consisting of high / low voltage cut off, maintenance free isolated Electronic driverwith over voltage protection,surge protection and other safety test as per IS 15885 Part-2/Sec 13, Low THD, PMMA grade high quality Transmittance lens, Epoxy powder coated Die Cast Aluminium housing(heat sink) with UV stabilized optics, polycarbonate LENS for symmetricallight distribution,weather proof gasket for lamp & driver compartment, Heat resistance toughened UV stabilized glass fitted in cast aluminium housing with SS screws, complete all as specified and asdirected
43Supply and fixing hot pressed moulded Glass reinforced polyester sheet moulding compound (SMC) Junction box of dimensions 250mm x 200mm x 100mm, SMC confirming to IS: 13410:1992 Grade S 1 ,thickness of SMC sheet not less than 1.5mm, outdoor type, single door hinged with front side opening, weather proof, suitable locking arrangement at front, arrangement for incoming and out going cable entry at the bottom ,earthing arrangement using One no. of Earthing bolt of MS with 2 nuts and 2 washersprovided on RH side of box, Earthing sign has to be provided near to earthing boltcomplete all as specified and comprising ofthe followings items as under:-(a) single phase and neutral bus bardulycolour coded of capacity 100 amps usingaluminium strips of size 25mm x 4mm mounted on epoxy resin base insulators, drilled holes for cable connection on bus bar including provision of PVC cable of suitable size and length from bus bar to MCB .(b) MCB SP 5 to 32 Amps,- 01 No(c) Provision of clamp for mounting on pole/wall,clamp made from 20mm x 1.5mm flat iron of suitable shape and length duly fixed with nuts & bolts on the rear side of box
44Supply, installation, testing and commissioning of LT Junction boxoutdoor typeof size 120cm x 75 cm x 45 cm with provision of aluminium busbar three phase and neutral(TPN) with 4 stripeach 100 amps capacity and 75 cm longduly colour coded,mounted on epoxy resin base insulators, drilled holes for cable connection on bus bar confirming of IS 8623 Part (one), CPRI approval, totally enclosed vermin proof suitably ventilated for 3 phase, 4 wire 415 Volts, 50Hz, AC supply, outer sheel shall be made out of 3.00mm thick CRCA sheet & MS angle section of suitable size for frame, factory fabricated. Front and back door opening. Protection of enclosure IP 56 as per IS-2147 of 1962 with pre-treatment trhough 7 tank hot chemical process prior to powder coated with minimum 50-70 micron of approved colour. The bottom of outer shell contains a detachable plate having provision for entry of armoured cable of adequate size. Computer cut self adhesive vinyl danger notice plate having conventional symbol of bones and skull to be provided. EPDM gasket of appropriate shape and size provided at all joints, door and covers including suitable size angle iron/flat iron frame work/support required with four legs 60 com long using angle iron 40x40x6mm, and locking arrangement at front with duplicate keys and making connection of incoming and outgoing cable using proper cable lugs, legs grouted in PCC 1:2:4 and making good distrubed surface complete all as specified and as directed
45Total amount ofSch "A" PART-XI (SEC-II) (EXTERNAL ELECTRICAL SUPPLY WORK)
46Total amount ofSch "A" Part-XII (SITE CLEARANCE, EXCAVATION AND EARTHWORK)
47NOTE: Amount against schedule of credit for retrieved materials mentioned under relevant part of Sch of Credit of tender document in PDF form will be deducted offline/manually from overall amount quoted by the lowest bonafide bidder during award of contract.
Disclaimer :
We takes all possible care for accurate & authentic tender information, however Users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender.
Tell us about your Product / Services,
We will Find Tenders for you

Copyright © 2024 · All Rights Reserved. Terms of Usage | Privacy Policy

For Tender Information Services Visit : TenderDetail