Tender For Electrical Installation Works Of Proposed 10 Beded Eye Ward With O.T (At 1St Floor) At Khatra S.D.Hospital, Khatra Under Bankura Electrical Sub-Division-Ii,P.W.Dte
Tender Value
Ref. Documents
Estimated cost
Bid Submission
21 Aug 2023
0 days left
EMD
46496
Bank guarantee accepted
Document Fee
Ref. Documents
Non-refundable
Tender Type
Online
Tender Overview
Organization
Tender ID
Competition Type
NCB
Bidding Type
Tender
Location / State
khatra → West Bengal
EMD Exemption
Not Available
Quantity
Not Available
Website
Contact Person
Address
Project Description
Electrical Installation Works Of Proposed 10 Beded Eye Ward With O.T ( At 1St Floor ) At Khatra S.D.Hospital, Khatra Under Bankura Electrical Sub-Division-Ii, P.W.Dte
BOQ
| Sl. No. | Item Description |
| 1 | Supplying and fixing 32A,415 V TPN SFU with sheet steel enclosure on angle iron frame on wall with nuts bolts etc. incl. S&F 3nos DIN type HRC fuse as per rating. (For Autoclave) (Make- Siemens/ L&T/ Havells) |
| 2 | Supplying and fixing double door Vertical TPN MCB Distribution board for MCCB incomer with IP-42/43 protection, on angle iron frame on wall & mending good the damages to original finish incl. Inter connection with suitable size of copper wire and neutral link & provision for earthing attachment.Make-Legrand/Schneider/Crabtree/Seimens/ABB. 4 way (Up to 160A) [Enclosure (607913)] |
| 3 | Supplying and fixing double door Horizontal TPN MCB Distribution board with IP-42/43 protection, concealed in wall after cutting the wall & mending good the damages to original finish incl. Inter connection with suitable size of copper wire and neutral link & provision forearthingattachme. (Make-Legrand /Schneider/ Crabtree/Seimens/ABB) 8 way [Enclosure (607717)] |
| 4 | Supplying and fixing double-door SPN MCB Distribution Board with IP-42/43 protection, concealed in wall after cutting the wall & mending good the damages to original finish incl. Inter connection with suitable size of copper wire and neutral link & provision for earthing attachment.Make-Legrand/Schneider/Crabtree/Seimens/ABB.2+12 way [Enclosure (607712)] |
| 5 | Supplying and fixing double door sheet steel (16SWG), powder coated cable end box for TPN DB horizontal / vertical enclosure with IP-42/43 protection, on angle iron frame on wall & mending good the damages to original finish with nuts bolts etc incl. provision for earthing attachment.4 way |
| 6 | Supplying and fixing 415 V four poleMCCB of breaking capacity 25kA/35kA with fixed thermal and fixed magnetic/adjustable thermaland fixed magnetic setting in existing DBs/ enclosure and necessary connection Make- Legrand, ABB, Siemens,Schneideras to GS. 100A |
| 7 | Supplying and fixing 240/415 V Isolator on din rail of existing DBs and necessary connection. Make LEGRAND, ABB, SIEMENS, CRABTREE, SCHNIDRR as to GS. 415 V, 63A FP |
| 8 | 240 V, 40A DP |
| 9 | Supplying and fixing 240/415V,MCB of Breaking capacity 10kA & C characteristics on din rail of existing DBs and necessary connection Make- Legrand, ABB, Siemens,Schneider as to GS. 6A - 32A SP MCB |
| 10 | 63A TP MCB |
| 11 | Distribution wiring in 1.1 KV grade 2x22/0.3 (1.5 sqmm) single core stranded \"FR\" PVC insulated & unsheathed copper wire (Make- Havells/Polycab/Finolex) partly in 20mm size PVC rigid conduit \"FR\" (Precision make) [for ceiling portion only] and in 19mm bore, 3mm thick polythene pipe [for horizontal & vertical run embedded in wall], with 1x22/0.3 (1.5 sqmm) single core stranded \"FR\" PVC insulated & unsheathed copper wire for ECC, to light/fan/call bell points with Piano Key type switch fixed on MS CRC sheet metal (16 SWG) switch board on wall complete with 2 no. “Ph & N” copper bar incl. bakelite/ Perspex top cover 3 mm thick and incl. 175x100x65mm inspection box, making earthing attachment, painting the MS box and mending good the damages to original finish [only PVC Rigid Conduit on ceiling and remaining portion concealed] Average run 9 mtr |
| 12 | Distribution wiring in 1.1 KV grade 22/0.3 (1.5 sqmm) single core stranded \"FR\" PVC insulated & unsheathed copper wire (Brand approved by EIC) in 20mm size PVC rigid conduit \"FR\" (Precision make), with 1.1 KV grade 1 x 22/0.3 (1.5 sqmm) single core stranded \"FR\" PVC insulated & unsheathed copper wire as ECC, to 5A 3 pin flush type plug socket & Piano Key type switch fixed on MS CRC sheet metal (16 SWG) switch board cum JB on wall incl. bakelite/Perspex (wall matching color) top cover 3 mm thick and incl. painting the MS box and mending good the damages to original finish. On Board |
| 13 | Supply & Fixing 240 V, 3 nos. 6A, & 1 no. 20A plug socket with separate 3 nos. 6 A & 1 no. 20A Piano key type switch, indicator & 20A switch type SP MCB (Brand approved by EIC) on sheet metal switch board embedded in wall incl. S & F 240x200x65mm MS (16SWG) switch board and bakelite/perspex top cover of 3mm thick by Brass screws after making housing for switch by cutting bakelite/perspex cover and making necessary connections as required. |
| 14 | Supply & Fixing 240 V, 2 x 6A, plug socket with separate 6 A Piano key type switch (Brand approved by EIC) on sheet metal switch board embedded in wall incl. S & F 200 x 150 x 65 mm MS (16SWG) switch board and bakelite/perspex top cover of 3mm thick by Brass screws after making housing for switch by cutting bakelite/perspex cover and making necessary connections as required |
| 15 | Supply & Fixing 240 V, 20A, plug socket with separate 20 A Piano key type switch (Brand approved by EIC) on sheet metal switch board embedded in wall incl. S & F 150x100x65mm MS (16SWG) switch board and bakelite/perspex top cover of 3mm thick by Brass screws after making housing for switch by cutting bakelite/perspex cover and making necessary connections as required |
| 16 | Supply and Delivery 9 Watt LED lamp Philips/ Havells/Crompton make .as per direction of EIC. |
| 17 | Supply and delivery of Twin LED Fitting (2 X 20Watt, 230VAC, 50hZ,4000K NW, THD<10%, bult in 2.5KV SPD) with all accessories and 2 nos LED Tube [Make: PHILIPS, CROMPTON, BAJAJ, HALONIX, WIPRO, Panasonic, LEGARO, HAVELLES/ Jaquar.[NS] |
| 18 | Supply and delivery of Single LED Fitting (20Watt, 230VAC, 50hZ,4000K NW, THD<10%, bult in 2.5KV SPD) with all accessories and 1 nos LED Tube [Make: PHILIPS, CROMPTON, BAJAJ, HALONIX, WIPRO, Panasonic, LEGARO, HAVELLES/ Jaquar. |
| 19 | Supplying & Fixingangular batten holder(Anchor) on 75mm dia PVC round block/round bakelite on wall/ceiling. |
| 20 | Fixing only single/twin fluorescent light fitting complete with all accessories directly on wall/ceiling with HW block and ceiling plates, nipples etc. as required |
| 21 | Extra for suspension exceeding 25 cm with S&F additional 2 no. 20 mm dia EI conduit (14 SWG) supports & necy. PVC insulated wire and painting etc. as required by 2x24/0.20 mm (1.5sqmm.) flexible copper wire of 1.10 mt. length. |
| 22 | Fixing only single/twin fluorescent light fitting suspended 25 cm bellow the ceiling with 2 No. 20 mm dia EI conduit (14 SWG) supports fixed with “L” type MS clamp whose one side fixed on ceiling with sutable size 4 nos. fastener and other side connected with the conduit with suitable size of bolts and nuts incl. S&F EI conduit, “L” type (125mmx125mm) 6mm thick and 25mm with MS clamps and connecting the length of PVC insulated wire and mending good damages to original finish and painting etc. by 2x24/0.20 mm (1.5sqmm.) flexible copper wire of 1.10 mt. length. |
| 23 | Supply & delivary ofAC 240V 50 Hz48\" sweep (1200 mm) ceiling fan complete with down rod , Canopy, forkincl S & F of P - 2 type capacitor as per IS specification & proper Manufacturer certificateof the capacitor (supplied at the time of delivered the fans )etc. with out regulator,(Make- Usha (Striker plus Star CF Br/Wh)/ Crompton Greaves (HS Plus 5 star)Orient ( 5 Star )andas per direction of EICas per direction of EIC |
| 24 | Fixing only ceiling fan complete with blades, canopy, fork, rubber bush etc. incl. S&F connecting wire for down rod upto 30 cm incl. painting the rod with approved paint and making necessary connection as required by 2x1.5 sqmm flexible copper wire. |
| 25 | Extra for supplying additional wire for down rod & painting the rod exceeding 30 cm by 2x1.5 sqmm flexible copper wire. |
| 26 | Supplying & Fixing of MS fan clamp of two piece type, for RC Ceilingas per approved specification, fabricated from 40 mm x 9 mm MS Flat including making good damages to building roof with satisfactory finishing and painting - – (As per Drawing no. 475 of PWD Specification Book – May 1991). |
| 27 | Supply & Fixing Socket type fan regulator (Step type) (Brand approved by EIC) on existing sheet metal switch board with bakelite/ perspex top cover by screw incl. making necy. connections etc. |
| 28 | Supply and delivery of 230V 30cm(12\") 1420 rpmHeavy Duty Exhaust fan with all necessary accessories [Make: EPC , Usha,CG,Bajaj or equivalent Make] |
| 29 | Fixing only exhaust fan after making hole in wall and making good damages and smooth cement finish etc. as practicable as possible and providing necy. length of PVC insulated wire and making connection for exhaust of following diameter: 30 cm (12\") |
| 30 | Supply & Fixing louver shutter on wall with necy. bolts & nuts (6 mm dia x 62 mm long). For Al 30 cm Exhaust fan (12\") |
| 31 | Supplying of following sizes Al. armoured PVC/XLPE(Havells/ Glostar/ KEI/ RR kabel ) as per direction of EIC. 4 Core 50 sqmm (From Panel to VTPN DB) |
| 32 | 4core 35sqmm( From VTPN to HTPN DB ) |
| 33 | 4 core 25sqmm(From VTPN to Autoclave main switch) |
| 34 | 2 core 10 sqmm (For compound light) |
| 35 | Laying of cable as below, after cutting floor/ pavement/ wall/ and making holes incl., embedding the cable at an average depth as below and mending good the damages to original finish incl. removing the rubbish.4 core 50 sqmm |
| 36 | 4 core 35 sqmm |
| 37 | 4 core 25 sq mm |
| 38 | 2 core 10 sq mm |
| 39 | Supplying & fixing medium gauge GI pipe (ISI-Medium) protection with necessary fittings and jointing metarials as required.65 mm dia |
| 40 | Supplying and fixing compression type gland complete with brass gland, brass ring & rubber ring for dust & moisture-proof entry ofXLPE/PVC armoured cables as below.4 core 50 sq mm |
| 41 | 4core 35 sq mm |
| 42 | 4 core 25 sqmm |
| 43 | 2 core 10 sqmm |
| 44 | Finishing the end of following XLPE/PVC armoured cables by crimping method incl. supplying and fixing solderless socket (Dowels make), tapes, anticorrosive paste & jointing materials.4 core 50 sq mm |
| 45 | 4core 35 sq mm |
| 46 | 4 core 25 sqmm |
| 47 | 2 core 10 sqmm |
| 48 | Supplying and Drawing 1.1 KV single core stranded \"FR\" PVC insulated & unsheathed single core stranded copper wire (Brand approved by EIC) of the following sizes in the prelaid polythene pipe and by the prelaid GI fish wire and making necy. connection as required. 2 x 84/0.3 (6 sqmm) + 1 x 56/0.3 (4 sqmm) ECC |
| 49 | 2 x 56/0.3 (4 sqmm) + 1 x 36/0.3 (2.5 sqmm) ECC |
| 50 | 2 x 36/0.3 (2.5 sqmm) + 1 x 22/0.3 (1.5 sqmm) ECC |
| 51 | 2 x 22/0.3 (1.5 sqmm) + 1 x 22/0.3 (1.5 sqmm) ECC |
| 52 | Finishing of the PVC insulated wire ends by socketting with pin/ring type copper sockets and insulated tapes etc., including supplying sockets, tapes. as per G S 6.0sq mm |
| 53 | 4.0sq mm |
| 54 | 2.5sq mm |
| 55 | Supply and Delivery of LED Street Light(230V AC,70 w ,5500K,IP 66,THD<10%,bult in 2.5KV SPD) with all necessary connection.(Cat No- TRP-409-70-57-SL-GL-NSG) [Make:Philips,Crompton,Bajaj as per EIC.] |
| 56 | Fixing only outdoor / street light type fluorescent light fitting or MV light fitting complete with all accessories to be fixed /projected from the wall of the building incl. making holes/providing clamping arrangement & necy. GI reducer as required. S&F 40 mm GI pipe (ISI-Medium) quality 1.5 mts. average length having suitable bend S&F necy. length of 1.5 sqmm PVC insulated single core stranded annealed copper wire and making connections as required and mending good damages to wall incl. painting etc. |
| 57 | Supplying & Fixing GI waterproof type looping cable box size 200x150x100 mm deep having 4 mm thick comprising of one 250 V 15 A kit-kat fuse unit, one NL on porcelain insulator, one compression type brass cable gland for upto 2- core 16 sqmm PVC/A cable and having lined with rubber gasketted GI top cover with brass machine screws etc., earthing terminal with lug, on steel tubular pole near base, including S&F 40x6 mm thick, MS clamps with bolts, nuts etc. including painting with anticorrosive paint. |
| 58 | Supplying and fixing Street light/Outdoor light/Compound light Timer DB(water proof) concealed in wall after cutting the wall & mending good the damages to original finish incl. Inter connection with suitable size of copper wire and neutral link & provision for earthing attachment and fabricated with following items as per instructions of EIC i)240 V,6-32A SPMCB of breaking capacity 10KA & \"C\" Characteristic-----01nosii) Double door SPN MCB Distriution Board with IP-42/43 protection 10/12 way Enclosures reqd.(Make:Legrand/L&T)---1no iii) 250 V,50Hz,40Amp DP Contractor with (2NO or 1 NO + 1NC Aux. Contract) (Make: Legrand/L&T)----1no.iv) 250 V,50Hz,40Amp DP MCB Isolator(Make:Legrand/L&T)---1nov)Astronomical time switch---01 Nosvi)Toggle switch for manual/auto operation---01 nos vii) The complete arrangement must be wiring by 2.5 sqmm PVC Insulated copper wire with suitable length incl. socketing/Lugs etc. as per requirement & Direction of EIC. (Make:Legrand/l&t/Crabtree) |
| 59 | Earthing with 50 mm dia GI pipe 3.64 mm thick x 3.04 Mts. long and 1 x 4 SWG GI (Hot Dip) wire (4 Mts. long), 13 mm dia x 80 mm long GI bolts, double nuts, double washers incl. S & F 15 mm dia GI pipe protection (1 Mts. long) to be filled with bitumen partly under the ground level and partly above ground level driven to an average depth of 3.65 Mts. below the ground level as below: By ISI-Medium GI pipe |
| 60 | Excavation of soil for installation of Earth Electrode and filling & ramming. For morrum Soil |
| 61 | Supplying & fixing earth busbar of galvanized (Hot Dip) MS flat 40 mm x 6 mm on wall having clearance of 6 mm from wall including providing drilled holes on the busbar complete with GI bolts, nuts, washers, spacing insulators etc. as required. |
| 62 | Connecting the equipments to earth busbar including S & F GI (Hot Dip) wire of size as below on wall/floor with staples buried inside wall/floor as required and making connection to equipments with bolts, nuts, washers, cable lugs etc. as required and mending good damages solid GI Wire. No. 6 SWG |
| 63 | Supply & Delivery of single phase 230V, 50 Hz A.C. Split type room air conditioner 1.5 ton capacity fitted with rotary/ reciprocating fixed speed compressor & copper cooling coil nominal cooling capacity: 4500 (KCal / h r.), cooling capacity minimum guaranteed 4250 K.Cal/hr, Minimum room discharge Air Flow 700 Cub.m/h, EER (w/w) 2.7-2.89, Star rating: 3 - Star Rated Energy efficient, incl. Remote etc. complete with 25 Amp suitable plug top as per direction of E1C (Make Hitachi / Mitshubisi / 0 General ) .[ASGA18BMWA-B (R32)] |
| 64 | Installation of the Split type 1.5 Ton 2.0 Ton A.C machine incl cutting of wall etc incl S & F suitable sizes Copper pipe of same make for Suction & Liquied line with insulation incl. S & F drain pipe of reqd. length to comp. the instn and mending good the damages as per direction of EIC. |
| 65 | S & F laying of- (i) gauge copper pipe 5/8\" 0.7 mm thick for suction (ii) copper pipe 1/4\" 0.6 mm thick for discharge (OEM make) with 9 mm thick thermal insulation foam nitrile / rubber / K Flex / Accroflex with max saddling with max 1 mtr distance both for suction & discharge pipe and mending good the holes & damages as directed by EIC.(extra length for distance of ODU & IDU exceed3mtr.) |
| 66 | S & Laying 3 core 2.5 sqmm PVC insulated & unarmoured copper wire (make--Finolex/Havells/KEI/Gloster) for 1.5/2 Tr. Split AC machine (extra length for distance of ODU & IDU exceed 3 mtr.) with max saddling with max 1 mtr distance as per direction of EIC. |
| 67 | S & F of flexible PVC high quality water carrying pipe of 25 mm dia/proper sizefor drainage the condensate water from already installed AC to any available (nearest) drain water pipe or near to ground level and the pipe must be properly saddled with the wall incl. proper insertion of the flexible pipe to drain water pipe and sealing the entry with required materials like PVC tape, High quality sealing the entry with required materials like PVC tape, high quality sealing gum etc. as reqd. All these arrangement for fixing must be arranged by the agency itself as per direction of EIC. |
| 68 | Supply & Fixing 240 V, 25 A, 3 pin Modular type plug socket (Brand approved by EIC), without plug top and switch with 2 Module GI Modular type switch board with top cover plate flushed in wall and making necy. connections with PVC Cu wire and earth continuity wire etc |
| 69 | Supply & Fixing 240 V,25 A, 3 pin Modular type plug top with indicator (Brand approved by EIC) & necy. Connections. |
| 70 | Supplying and fixingof250 V AC timers fixed on wall withflat iron frame as per directionof EIC and the Box shuldbe comprising with the following accessorise ---i) Double-door SPN MCB Distribution Board with IP-42/43 protection10 / 12way Enclosureas reqd .( Make -Legrand / L & T) –1 no ii) 230 V , 50 Hz ,16 Amp Single dial 1 x 24 Hrs.Timer ( Microrex QT31 )of quartz driven running reserve Day dial back up by nickle cadmium battery (Make - GEC / Legrand) – 1 noiii) 250 V, 50 Hz , 40 Amp DP Conctractor with (2 NOor 1 NO + 1 NC Aux. Contract ) ( Make -Legrand / L & T)– 1 no iv) 250 V,50 HZ ,40 Amp , DPMCBIsolator ( Make -Legrand/L & T)– 1 nov) Auto / Manual By pass Toggle Switcharrangement – 1 no. vi) 250 V ,Diode type neon Indicator lamp ( Make -Legrand/L & T)– 1 no vii)Bakelite base with FP bolt typestud/ Terminalblock inclS & F Neutral Bar etc with this box for termination of power .viii) The complete arrangement must be wiring by 2.5 Sq mmPVC insulated Cu wire withsuitablelengthinclsocketing /lugs etc as per requirement &direction ofEIC (Make -Legrand/L & T / Crabtree) |
| 71 | S & F 240V 25A OLP - 30 Electrronic motor starter in 175mm X 100mm X 65 mm depth 16 SWG MS Box coneled in wall with bakelite top cover incl. Necy. Conncetionas per direction of EIC for AC Machines |
| 72 | Supply & FixingLightning conductor Air-terminals made of 15 mm dia1500 mm long GI pipe (ISI Medium) having five prongs of 4 SWG GI (Hot Dip) wire at top with 85 mm dia 6 mm thick GI base plate at bottom incl. necessary holes etc. duly grouted on the parapet etc. in CC mortar (4:2:1) |
| 73 | Cutting cornices/ steps etc. including cutting recess in buildings etc. & supply & fixing 15 mm bore (ISI-Medium) GI pipe protection as below and mending good damages to the building works:Length upto 0.5 Mtr |
| 74 | Length above 0.5 Mtr |
| 75 | Making soldered joints between conductors, conductors and air terminals for 4 SWG GI (Hot Dip) wire incl. supply of jointing materials and painting with 2 (two) coats of bituminous paint. |
| 76 | Making soldered joints between conductors and down pipes/ other metallic objects for 14 SWG GI (Hot Dip) wire including supply of necessary 4 SWG GI (Hot Dip) wire, jointing materials and painting with 2 (two) coats of bituminous paint. |
| 77 | Hiring charges for scaffolding arrangement including dismantling at the end of work and carriage, for LC installation, per storey of building per vertical run. |
| 78 | Supply & fixing GI (Hot Dip) strips 20 mm x 3 mm thick for horizontal run on the Parapet/Roof/ Wall with GI Saddles 1100 mm apart incl. mending good the damages to building works. |
| 79 | Supply & fixing of GI (Hot Dip) strips 20 mm x 3 mm thick for vertical run on wall with GI saddles spaced not exceeding 1000 mm apart incl. mending good damages to building work. |
| 80 | Supply & Fixing of Testing Joints by 20 mm x 3 mm thick GI (Hot Dip) strip 125 mm long grouted on wall having clearance of 6 mm from wall for making connection with thimbles at the end of 7/10 SWG GI (Hot Dip) stranded Wire and 4 SWG GI (Hot Dip) wire of vertical conductor and conductor from earth electrode complete with S & F thimbles, GI bolts, nuts, check-nuts, spring washers etc. as required. |
| 81 | Excavation of soil for installation of Earth Electrode and filling & ramming as to GS. For morrum soil. |
| 82 | Earthing with 50 mm dia GI pipe 3.64 mm thick x 3.04 Mts. long and 1 x 4 SWG GI (Hot Dip) wire (4 Mts. long),13 mm dia x 80 mm long GI bolts, double nuts, double washers incl. S & F 15 mm dia GI pipe protection (1Mts. long) to be filled with bitumen partly under the ground level and partly above ground level driven to an average depth of 3.65 Mts. below the ground level & restoring surface duly rammed (For Morrum Soil By ISI-Medium GI pipe as toGS. |
| 83 | Supplying & fixing earth busbar of galvanized (Hot Dip) MS flat 25 mm x 6 mm on wall having clearance of 6 mm from wall includingproviding drilled holes on the busbar complete with GI bolts,nuts, washers, spacing insulators etc. as required as to GS. |
| 84 | Supplying & fixing earth busbar of galvanized (Hot Dip) MS flat 40 mm x 6 mm on wall having clearance of 6 mm from wall including providing drilled holes on the busbar complete with GI bolts, nuts, washers, spacing insulators etc. as required. |
| 85 | Extra for providing masonery enclosure on the top of the earth electrode of overall size 86.36 cm x 86.36 cm x 46 cm deep (below Ground level) complete with cemented brick work(1:6) of 25 cm width duly plastered with cement morter (inside) CI hinged inspection cover of size 36.56 cm x 35.56 cm with locking arrangement, GI reducer including drilling of 46 nos. 12 mm dia holes on the GI pipe. |
| 86 | SITC of 6 KVA ONLINE UPS SYSTEMTopology, IGBT BASED DSP CONTROLEDInput Voltage: 230 VAC, 160 - 270 VACInput Frequency: 50 Hz, 47 to 53 HzInput PF: > 0.99Output Voltage: 220 VAC +/- 1%Output Frequency: 50 Hz +/- 0.1% in Free running & +/- 4% in SyncIsolation Transformer: Provided Inbuilt (No external tranformer accepted )Power Factor: 0.8 Lag to UnityCrest Factor: 3:1Waveform: SinusoidalTHD: < 3% on linear load & < 5% on non-linear loadOverload: 110% for 10 minutes, 125% for 1 minutes, 150% for 30 msecTransient Response : For 0 - 50% & 50% - 100% load change voltage remains within +/- 5%Ripple: < 2% Inverter Efficiency: > 93% Battery : 12 V, Mono Block batteries.Battery Back UP: 120 mim back up minimum VAH required 15600 VAH Battery Make: Exide, Amar Raja Quanta |
| 87 | Battary Cabine: With power coated MS angle with MS sheet suiteble dimention and gadge,Protections: Input & Output Over / Under Voltage, Single PhasingDC - High / Under Voltage, Battery Charging Over Current, Output Overload / Short Circuit / Over Temp., UPS auto ON on Mains recoveryAudio Alarm, Mains Fail, Battery Low Pre-alarm, Inverter TripMetering: Digital Seven segment- Voltage, Current& Frequency, Battery - Voltage & CurrentIndications:Mains - On / Fail / High / Low / Single PhasingDC - On / High,Battery - Low Pre-alarm / Low Trip Inverter - On / Trip / High / Low / Over CurrentSwitchgear: MCB / MCCB for Input, Battery, Output & Manual Bypass SwitchTermination: Input, Battery, Output & Bypass Enclosure: IP 20Operating Temp: 0 to 40 Deg CHumidity: Upto 95% Rh (non-condensing)Cooling: Forced AirNoise: < 55 dBCharging Current: 5 to 10 Amps. (Site Settable)Cold Start : ProvidedCommunication: RS 232Static Switch: Provided with changeover < 5 msec in sync & < 20msec in non-syncCertification : ISO 9001: 2015, ISO 14001: 2015, ISO 18001, RoHS and OHSAS 18001 IEC/EN 62040-1-1,IEC/EN50091-1,IEC/EN 60950 (Safety) IEC/EN 50091-2, IEC/EN 62040-2(EMC Emmission),IEC/EN 62040-3(performance & Design)IEC/EN 61000-4(EMC Emmunity) & IEC/EN 60146 (Design & Manufacture) [Make- APC/ Neumeric/ Emerson/ Vertiv/ Power One/ Avo] |
| 88 | i) Supply and fixing of angle iron frame fabricated from 40 mm x 40 mm square four nos hollow bar with cross and radial support including one no 40x40 mm angle iron support in the middle for the Sign board of following sizewith suitable three nos. crosss angle support welded with 4 nos angle hook in equal space for fixing on the structurewith all necessary welding and fabrication. The structure shall rest in both sides with proper welding as per instruction of EIC. ii) S&FLED Sign Board made 3 mm thick ACP Sheet (Alstrong/ Aludecor) finished with approved metallic colour as back ground (blue) after router cutting. The riser structure also shall be covered with ACP Sheet.& appx 6-7 inch depth (Both size ACP sheet) iii) S&F Special type of imported acrylic English letter appx 50 mm thickness flushed on the ACP boardmade on imported acrylic ACAST sheet. The followingletter font shall be in horizontal line as mentioned.iv) S&F SMD LED inside theboard and to run for each letter including wiring , soldering etc and fixing the SMPS properlywith the specification of the SMD --- 1. LED colour :White/ Red/ Blue (make-samsung /Nichia /Cree/Hisine)2.Stright :2 or 3 nos LED per module3. Luminous Flux : 140 LUMEN 4. Life : 70000 burning hours 5. Visibility:100 meter atleast normal eye6. Power Supply:1.2 watt to1.6 wattper module7.Input : 230A.C ,Output :12V DC8.Shape of LED :recrangle or square9. Grade: IP - 65 v) S & F LED Power supply 300/ 400WIP65 50/60Hz frequency, 108 to 305 VAC driver power supplyother electrical accessoriesthe panel prepared along with its necessary arrangement ( makeHisine/Migion/Cehosa/PWD appvd )vi) Cost of painting of MS structure with 2 coats of RO primer and one coat of synthetic enamel paint after scrapping with emery paper properly make ICI/Asian paintsvii) Cost of erection of scaffolding for fixing the Signageviii) Testing and commissioning of the LED board as per following nomenclature ix) cost of carrying the LED sign board from work shop to site |
| 89 | Supply, installation, Testing & commissioning of Microprocessor based addressable type fire alarm control panel with LCD display with network card.The Fire Alarm Panel shall have Minimum 1 loop and expantion capacity of two loop, with relay controls.The PANEL shall be able to generate History Events. The panel should be capable to acknowledge, singnal silence and reset function of event. The Panel shall have provision for Alarm,Trouble relay and Modbus/Bacnet/Lanworks. The Panel should have VDS/VL/FM/VLC (Make : Honeywell-Notifier /Honeywell-Esser/ Bosch/ Simens/ Johnson Control/Apollo/Morley Sensor/Secutron/securiton). |
| 90 | Supply, installation, Testing & commissioning of Addressable multicriteria (capable to detect smoke and heat) detector with base, with LED indication.VDS/VL/FM/VLC approved make. (Make : Honeywell-Notifier /Honeywell-Esser/ Bosch/ Simens/ Johnson Control/Apollo/Morley Sensor/Secutron/securiton). |
| 91 | Supply, installation, Testing & commissioning of Addressable heat detector with base, with LED indication.VDS/VL/FM/VLC approved make. (Make : Honeywell-Notifier /Honeywell-Esser/ Bosch/ Simens/ Johnson Control/Apollo/Morley Sensor/Secutron/securiton). |
| 92 | Addressable Manual call point for manual Fire signaling VDS/VL/FM/VLC approved. (Make : Honeywell-Notifier /Honeywell-Esser/ Bosch/ Simens/ Johnson Control/Apollo/Morley Sensor/Secutron/securiton). |
| 93 | Addressable Combined Sounder and Strobe with programmable alarm tones and with require modules. VDS/VL/FM/VLC approved. (Make : Honeywell-Notifier /Honeywell-Esser/ Bosch/ Simens/ Johnson Control/Apollo/Morley Sensor/Secutron/securiton). |
| 94 | Supply, Installation, Testing & commissioning of Isolator module for emergency loop circuit isolation in case pf any type short circuit in loop. Product should be VDS/VL/FM/VLC approved. (Make : Honeywell-Notifier /Honeywell-Esser/ Bosch/ Simens/ Johnson Control/Apollo/Morley Sensor/Secutron/securiton). |
| 95 | 2Cx 1.5 Sq. mm Twisted copper FRLS , Cable fixed on the surface/through 25 mm PVC (Precision- M/AKG/Atul) conduit of the building structure complete with termination and testing as per requirement. (Make : RR Kabel/Havells/Gloster/Finolex). |
AI Tender Summary
Tender Timeline
Aug 07, 2023
11:30 IST
Tender Published
Tender notice published.
CompletedAug 21, 2023
17:00 IST
Bid Submission Deadline
Online submission via eProcurement portal.
CompletedAug 23, 2023
Bid Opening Date
Technical bids will be opened and evaluated.
CompletedTender Documents
Download All (ZIP) ↓
Disclaimer
We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender