Tender For Providing Ei For Oxygen Concentrator Of Rgm Hospital Dchc Kailashahar Unakoti Tripura, kailashahar-Tripura

Public Works Department-PWD has published Tender For Providing Ei For Oxygen Concentrator Of Rgm Hospital Dchc Kailashahar Unakoti Tripura. Submission Date for this Tender is 25-08-2023. Medical Gas System Tenders in kailashahar Tripura. Bidders can get complete Tender details and download the document.




Tender Notice

39019027
Tender For Providing Ei For Oxygen Concentrator Of Rgm Hospital Dchc Kailashahar Unakoti Tripura
Open Tender
Indian
Tripura
kailashahar
25-08-2023

Tender Details

Providing Ei For Oxygen Concentrator Of Rgm Hospital Dchc Kailashahar Unakoti Tripura

Key Value

Document Fees
INR 1000 /-
EMD
INR 7659.0 /-
Tender Value
INR 3.82 Lakhs /-

BOQ Items

Name of Work:-Providing EI for Oxygen concentrator of RGM Hospital DCHC, Kailashahar, Unakoti Tripura.
Sl. No. Item Description
1Providing and fixing of 3/6 pin 16/20 amps plug point withmodulartype 16/20ampsswitch andsocketincludingconnectionwith 2x2.5 sq. mm PVC insulated Copper conductor cable (FR) on surface modularswitch board, earthing the 3rd pin etc. as required:- (As per TSR 2021, Sl- 204)
2Wiring for circuit /Sub-main with following sizes PVC insulated copper conductor cable (FR) in PVC casing and capping etc. as required. (As per TSR 2021, Sl-205)
32 X 4 sq mm
42 X 6 sq mm
54X 10 sq mm
6Wiring for Circuit/Sub-main with the following sizes of PVC insulated Copper conductor cable (FR) in existing PVC casing capping/ conduit in recess/surface including connection etc. as required:- (As per TSR 2021, Sl- 503))
71 X 2.5 sq mm
81 X 6 sq mm
9Providingearthing systemwith maintenance free earthing electrode of 50 mm dia & 3 mtr long of dual electrode technology filled with highly conductive compound and back fill compound of 2 nos. 25 kg bag, terminalsize 32mmx 6mm including accessories with masonry enclosure of CIcover plate size 12"x 12" having locking arrangement including CC works etc as required:-.(As per TSR 2021, Sl- 717)
10Proving and fixing / Drawing 4.06 mm dia (8 SWG) Copperwire on surface or inexisting G.I / PVC / Polythene pipe for loop earthing as required. (As per TSR 2021, sl no.707)
11Providng and laying 15mm dia(medium gauge) G.I. pipe for drawing of4.06mm (8SWG) dia G.I./ Copper wire forearth connection from earth electrodes etc as required. (As per TSR 2021, sl no.710)
12Supplying and fixing of MS frame made of (25mm x 25mm x 5mm) MS angle with necessary support by (40mm x 6mm) MS flat and 12 mm thick marine plywood on top, grouted on wall with 4 noslegs (25mmx25mmx5mm MS angle20 cm long) finishedwith red oxide and 2 coat synthetic enamel paintincluding necessary cc work, mending the damages & painting etc as required:-(As per TSR 2021, Sl.no.1502)
13Supplying and installation of Switch disconnector fuse unit (main switch) of the following ratings with all accessories including necessary connection etc. as required:-(As per TSR 2021, sl no.1202)
14100 amps 415 volts TPN main switch (rewireable):-
15Supplying and installation of Bus bar chamber of the following ratings and sizes made of steel sheet enclosure with all accessories including necessary connection etc. as required:-(As per TSR 2021, sl no.1201)
16100 amps 415 volts four strip Copper busbar chamber 6 ways of size (610mmx410mmx120mm):-
17Supplying and installation of change over switch of following ratings with enclosure including necessary connection etc. as required:-(As per TSR 2021, sl no.1204)
18100 amps FP on load change over switch (Front handle with enclosure):-
19Supplying and installation of powder coated steel sheet enclosure (MCB DB) suitable for 240/415 volts MCB/Isolator/RCCB (SP/SPN/DP/TP/TPN/FP) complete with necessary bus bar, neutral link, din rail, earth bar etc i/c connectionas required.(As per TSR 2021,sl-1208)
202+10/12 way SPN MCB DB (single door):
21Supplying & installation of 10 KA breaking capacity, B/C curve MCB of following ratings in the existing MCB DB including connectionas required:-(As per TSR 2021,sl-1215)
226 to 32 amps SP MCB
23Supplying & installation of isolators of following ratings in the existing MCB DB including connection etc as required:-(As per TSR 2021, Sl- 1217)
2440 amps DP isolator:-
25Supplying and fixing of MS frame made of (25mm x 25mm x 5mm) MS angle with necessary support by (40mm x 6mm) MS flat and 12 mm thick marine plywood on top, grouted on wall with 4 noslegs (25mmx25mmx5mm MS angle20 cm long) finishedwith red oxide and 2 coat synthetic enamel paintincluding necessary cc work, mending the damages & painting etc as required:-(As per TSR 2021, sl no.1502)