Tender For Comprehensive Repair / Maintenance Of Dg Sets Change Over Switches Amf Panels And Connected Items At Af Stn Naliya, naliya-Gujarat

Military Engineer Services-MES has published Tender For Comprehensive Repair / Maintenance Of Dg Sets Change Over Switches Amf Panels And Connected Items At Af Stn Naliya. Submission Date for this Tender is 25-08-2023. Diesel Generators Tenders in naliya Gujarat. Bidders can get complete Tender details and download the document.




Tender Notice

39007488
Tender For Comprehensive Repair / Maintenance Of Dg Sets Change Over Switches Amf Panels And Connected Items At Af Stn Naliya
Open Tender
Indian
Gujarat
naliya
25-08-2023

Tender Details

Comprehensive Repair / Maintenance Of Dg Sets Change Over Switches Amf Panels And Connected Items At Af Stn Naliya

Key Value

Document Fees
INR 500 /-
EMD
INR 30000.0 /-
Tender Value
INR 15 Lakhs /-

BOQ Items

Name of Work: COMPREHENSIVE REPAIRS/MAINTENANCE OF DG SETS,CHANGEOVER SWITCHES,AMF PANELS AND CONNECTED ITEMS AT AF STATION NALIYA
Sl. No. Item Description
1M & L for Servicing, testingof DG sets bytechnician /mechanic to the installations of DG sets of capacity upto 5 KVA to 30 KVA at various locations of air force station Naliya. Checking and testing complete DG setson load(Including engine, alternator, AMF panel, Body & chases complete) for its proper functioning and making a list of repairs/replacements required to be carried out in different parts of the DG sets. Carrying out general servicing and minor repairs and/or replacements complete all as directed for following jobs:- (i) Checking and cleaning of diesel filters & oil filters, checking only engine oil level and intimating the quantity of oil required for topping, oiling & greasing of engine, alternator battery incl tightening of nuts, bolts, lugs etc (ii) Checking and servicing of self starter, AMF panel including replacement/ tightening of nuts, bolts, lugs and other such minor works oiling & greasing, servicing of various parts of DG set such as timer, contactors, meters, etc. contd...
2contd.... (iii) Checking, cleaning and adjusting fan belt tension and cleaning & general servicing of exhaust/ silencer including checking for leakage of smoke & rectify. (iv) Checking, cleaning and tightening of electrical connections & cleaning of AVM pads, tightening / replacement of nuts, bolts, & washers.Checking & tightning of battery terminals and connections also topping up/complete replacement of battery Electrolyte if required.Battery Electrolyte cost is included in above rate. (v) Checking output of alternator and adjusting the same to specified values. Note: (a) Rates quoted by the tenderer are also deemed to include the cost of S&F in replacement of minors parts like nuts bolts washers lugs supply and applying oil & greasing and minor repairs to DG set.(b) List of repairs/replacements prepared by the contractor shall be submitted to the Engineer in charge for verification. (c) During servicing any new item required to fix will be intimated to Engr-in-Charge and measured and paid under relevant item.
3All as per item No.1 above but capacity 40 KVA to 62.5 KVA
4All as per item No.1 above but capacity 75 KVA to 100 KVA
5All as per item No.1 above but capacity 125 KVA to 250 KVA
6All as per item No.1 above but capacity 500 KVA
7M & L for preparing old painted surface of DG sets of capacity 5 KVA to 30 KVA (complete including engine, alternator, body & chases including its outer canopy) by thoroughly cleaning the surfaces to remove dirt, dust, rust flakes and paint flakes, using wire brush or sand papers, damp cloth or as directed. Priming the surface with anti corrosive primers using suitable sprayers. Applying automotive paint using sprayers till glossy finish is obtained, complete all as per manufacturers instructions and as directed. Make of paint: Nerolac / Asian / Berger or as approved by GE.
8All as per item No.6 above but capacity 40 KVA to 62.5 KVA
9All as per item No.6 above but capacity 75 KVA to 100 KVA
10All as per item No.6 above but capacity 125 KVA to 250 KVA
11S & F in repair Lead Acid batteries for DG Sets(DC power supply) of 88-90Ah,12 volt of make Exide/Amaron/Any approved make
12All as per item No.10 above but of capacity 120 Ah
13All as per item No.10 above but of capacity 150Ah
14All as per item No.10 above but of capacity 180Ah
15M & L for Servicing, calibration and phasing of FIP (Fuel injection pump) for nozzles including replacement of minor parts like nuts, bolts, washers etc including leak off test, Pressure test, automization of fuel etc for DG set of capacity 5 KVAto 30 KVA complete all as specified and directed. Note: All tests are to be done as per manufacturer instructions.
16All as per item No.14 above but capacity 40 KVA to 62.5 KVA
17All as per item No.14 above but capacity 75 KVA to 100 KVA
18All as per item No.14 above but capacity 125 KVA to 250 KVA
19All as per item No.14 above but capacity 500 KVA
20M & L for taking out Radiator by disconnecting from DG set of capacity 30 KVA to 63 KVA for repair welding, brazing, leak testing and descaling of radiators carried out by Radiwash or other non acidic base solution & refixing the same to its original position and testing on load complete all as directed.
21All as per item No.19 above but DG set of capacity 75 KVA to 100 KVA.
22All as per item No.19 above but DG set of capacity 125 KVA to 200 KVA.
23All as per item No.19 above but DG set of capacity 250 KVA to 500 KVA.
24M & L for repairing to alternator for charging of battery for DG set of capacity 5 KVA to 30 KVA complete overhauling & servicing of the alternator incl repair/replacement of unserviceable parts, assembling complete and testing all as directed.
25All as per item No.23 above but capacity 40 KVA to 62.5 KVA
26All as per item No.23 above but capacity 75 KVA to 100 KVA
27All as per item No.23 above but capacity 125 KVA to 200 KVA
28All as per item No.23 above but capacity 250 KVA to 500 KVA
29S & F in replacement Solenoid Switch for relay card suitable for 125 to 250 KVA DG set and testing complete for proper functioning.
30All as per item No.28 above but for 75 to100 KVA DG set
31All as per item No.28 above but for 40 to 62.5 KVA DG set
32All as per item No.28 above but for 10 to 30 KVA DG set
33All as per item No.28 above but for 500 KVA DG set
34S & F AMF panelRelay Panel (DC or AC as required at site) suitable for 30 to 200 KVA DG sets.complete all as specified and as directed. Make: Kirloskar/Cumins/ Greaves /Mahendra/Sudhir.
35S & F 4 pole Power contactor of rating 40-60 A suitable for DG AMF panel complete all as specified and as directed. Make- C&S/L&T/ Havells/Any approved make
36S & F 4 pole Power contactor of rating 80-100 A suitable for DG AMF panel complete all as specified and as directed. Make- C&S/L&T/ Havells /Any approved make
37S & F 4 pole Power contactor of rating 120-150 A suitable for DG AMF panel complete all as specified and as directed. Make- C&S/L&T/ Havells/Any approved make
38S & F 4 pole Power contactor of rating 200-250 A suitable for DG AMF panel complete all as specified and as directed. Make- C&S/L&T/ Havells/Any approved make
39S & F 4 pole Power contactor of rating 300-350 A suitable for DG AMF panel complete all as specified and as directed. Make- C&S/L&T/ Havells/Any approved make
40S & F 4 pole Power contactor of rating 350-400 A suitable for DG AMF panel complete all as specified and as directed. Make- C&S/L&T/ Havells/ Any approved make
41S & F in replacement of HRC Fuse of capacity 100 to 160 Amps complete all as specified and as directed.
42S & F in replacement of HRC Fuse of capacity 160 to 200 Amps complete all as specified and as directed.
43M & L for Removing, transporting to workshop, Repairing & Servicing of self starter of DG set ranging from 5 KVA to 30 KVAincluding replacement of parts such as washer, nut, bolts, bush, solenoid, rotor etc., re-assembling and testing complete all as directed.
44All as per item No.42 above but capacity 40 KVA to 62.5 KVA
45All as per item No.42 above but capacity 75 KVA to 100 KVA
46All as per item No.42 above but capacity 125 KVA to 200 KVA
47All as per item No.42 above but capacity 250 KVA to 500 KVA
48M & L for descaling of water jacket of engine by using of Radiwash or other non acidic base solutionwith pressure circulation pump, leak testing, soldering, brazing, checking for leaks and cleaning with clear water complete all as directed for DG set of capacity 5 KVA to 30 KVA.
49All as per item No.47 above but capacity 40 KVA to 62.5 KVA
50All as per item No.47 above but capacity 75 KVA to 100 KVA
51All as per item No.47 above but capacity 125 KVA to 200 KVA
52All as per item No.47 above but capacity 500 KVA
53S & F in replacement "V" belt for Radiator fan of DG set of capacity 5 KVA to 30 KVA. complete all as specified and as directed. Make: Fanner/Any approved make
54All as per item No.52 above but capacity 40 KVA to 62.5 KVA
55All as per item No.52 above but capacity 75 KVA to 100 KVA
56All as per item No.52 above but capacity 125 KVA to 250 KVA
57All as per item No.52 above but capacity 500 KVA
58Supply only in replacement/topping up ofEngine Oil multigrade (20 W 40) in engine oil tank ofDG sets all as specified and directed Make: IOCL/BPCL/HP/Any approved make
59Supply only in replacement/topping up ofEngine Oil multigrade (15 W 40) in engine oil tank ofDG sets all as specified and directed Make: IOCL/BPCL/HP/Volvoline/Any approved make
60Supply only Pre mix Coolant for DG Set as replacement or as topping up in radiator of various capacities complete all as specified and directed.
61M & L for cleaning of Diesel Tank of DG Set from inside by taking out diesel filled in tank and painting outer surface of tank with black paint and writing "Tank Cleaned on date" with white paint and again filling up diesel complete all as specified and as directed.
62Supply only Diesel filter primary & secondary suitable for DG set of capacity 5 KVA to 30 KVA of make Mahindra, Cumins, Kirloskar, greaves cotton and Crompton greaves etc complete all as specified and as directed.
63All as per item No.61 above but capacity 40 KVA to 62.5 KVA
64All as per item No.61 above but capacity 75 KVA to 100 KVA
65All as per item No.61 above but capacity 125 KVA to 200 KVA
66All as per item No.61 above but capacity 500 KVA
67Supply only in replacement of Oil filter suitable for DG set of capacity 5 KVA to 30 KVA make Mahindra, Cumins, Kirloskar, greaves cotton and Crompton greaves etc complete all as directed.
68All as per item No.66 above but capacity 40 KVA to 62.5 KVA
69All as per item No.66 above but capacity 75 KVA to 100 KVA
70All as per item No.66 above but capacity 125 KVA to 200 KVA Note: Both filters to be replaced at a time.
71All as per item No.66 above but capacity 500 KVA Note: Both filters to be replaced at a time.
72S & F in replacement of Ignition Switch of DG Sets & complete all as directed.
73S & F in replacement of Hose Pipe Set with clips complete with clips suitable for DG set of capacity 5 KVA to 30 KVA complete all as directed.
74All as per item No.72 above but capacity 40 KVA to 62.5 KVA
75All as per item No.72 above but capacity 75 KVA to 100 KVA
76All as per item No.72 above but capacity 125 KVA to 200 KVA
77All as per item No.72 above but capacity 500 KVA
78S & F in replacement of AVR ranging 50-110 volt DC for excitation with adjustable screws suitable for DG Set of capacity 5 KVA to 30 KVA complete all as specified directed.
79All as per item No.77 above but capacity 40 KVA to 62.5 KVA
80All as per item No.77 above but capacity 75 KVA to 100 KVA
81All as per item No.77 above but capacity 125 KVA to 250 KVA
82M & L for Repair/Replacementcontrol wiring of existing specifications and size of DG Set 10 to 62.5 KVA all as directed
83M & L for Repair/Replacementcontrol wiring of existing specifications and size of DG Set 70 to 100 KVA all as directed
84M & L for Repair/Replacementcontrol wiring of existing specifications and size of DG Set 125 to 200 KVA all as directed
85S & F in repairs of Battery Charger of 10 Amps for 12 Volt Battery complete all as specified and directed.
86S & F in repairs of Battery Charger of 10 Amps for 24 Volt Battery complete all as specified and directed.
87S & F in relacement of Water pump Complete for 30 to 62.5 KVA DG Set complete all as directed.
88S & F in relacement of Water pump Complete for 75 to 200 KVA DG Set complete all as directed
89S & F in relacement Diesel Pipe with benjo bolts, nuts and copper washers etc from Filter to Pump for DG Set of capacity 5 to 500 KVA complete all as directed
90S & F in relacement Diesel Pipe with benjo bolts, nuts and copper washers etc from Filter to Tank for DG Set of capacity 5 to 500 KVA complete all as directed
91S & F in relacement Oil pressure switch sensor(LLOP) for DG Sets of any capacity complete all as specified and directed.
92S & F in relacement Phase preventer of AMF Panel for DG Set of capacity 30 KVA to 125 kva capacity complete all as specified and directed.
93S & F in relacement magnetic coil for contactor suitable for DG Set of capacity 100 kva capacity complete all as specified and directed.
94S & F in relacement pulley of water pump of DG Sets of capacity 50 KVA to 200 KVA complete all as specified and directed.
95S & F in replacement of Electronic controll panel (ECP) for DG sets is microprocessor based generator set monitering and controll system. The control provides a simple operation interface to the Generator set, manual/ auto/stop control, shut down, fault indication and LCD hour counter as per existing size. The integration of all function into a single controll system of make of power controller suitable for 30 to 50 KVA capacity DG Set complete all as directed
96All as per item No.94 above but suitable for DG set of capacity 62.5 KVA to 125 KVA
97All as per item No.94 above but suitable for DG set of capacity 140 KVA to 250 KVA
98All as per item No.94 above but suitable for DG set of capacity 500 KVA
99S & F in replacement MCCB 63 A, 4 pole,415 Volts, 3/4 pole with fixed thermal & fixed magnetic settings complete all as directed by EIC. Make: Havells cat No.IHLGSF0063/ HPL/Schneider/ L& T
100All as per item No.98 above but capacity 100A, 4 pole Make: Havells cat No.IHLGSF00100/HPL/ Schneider/ L& T
101All as per item No.98 above but capacity 160A, 4 pole Make: Havells cat No.IHLGSF00160/HPL/ Schneider/ L& T
102M & L for repairing to alternator complete overhauling & servicing of the alternator 3 phase 4 wire 420 VoltsAC Alternator coupled with prime mover, dismantling from prime mover and transporting to workshop for rewinding incl repair/ replacement of unserviceable parts, rewinding and assembling complete and testing for DG set of capacity upto 5 KVA to 30 KVA.complete all as specified and as directed.
103All as per item No.101 above but capacity 40 KVA to 62.5 KVA
104All as per item No.101 above but capacity 75 KVA to 125 KVA
105All as per item No.101 above but capacity 140 KVA to 200 KVA
106All as per item No.101 above but capacity 250 KVA to 500 KVA
107Labour charges for complete checking of AMF control panel on DG sets or separate on site, finding the fault, servicing complete including replacement of unserviceable minor spares and testing complete for manual & Auto operations all as directed. Note: Supply only of new items required for replacement shall be measured & paid separately under respective item of schedule.
108Supply and install, testing off load type changeover switch of capacity 100 Amps 4 pole ,AC415 volts 50 HZ with enclosure, side handle operatedconforming to IS:13947 incl fixing on wall/panel complete all as specified and directed. Make: C&S/IndoAsian/Havells/HPL
109All as per item No.107 above but of capacity 200 Amps 4 pole
110General Note for all items : (i) Supply only of new items if required for replacement shall be measured and paid seperately under respective items of schedule.(ii) Rate quoted by contractor includes the cost of small parts such as washers,nuts,bolts etc and repair such as oil cooler servicing,connecting rod grinding,etc as directed.
Disclaimer :
We takes all possible care for accurate & authentic tender information, however Users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender.
Tell us about your Product / Services,
We will Find Tenders for you

Copyright © 2024 · All Rights Reserved. Terms of Usage | Privacy Policy

For Tender Information Services Visit : TenderDetail