Development Of Distribution Infrastructure In Tawang District Of Arunachal Pradesh Under The Revamped Reforms-Based And Results-Linked, Distribution Sector Scheme, tawang-Arunachal Pradesh

Department of Power has published Development Of Distribution Infrastructure In Tawang District Of Arunachal Pradesh Under The Revamped Reforms-Based And Results-Linked, Distribution Sector Scheme. Submission Date for this Tender is 27-09-2023. Distribution Transformer Tenders in tawang Arunachal Pradesh. Bidders can get complete Tender details and download the document.




Tender Notice

39007434
Corrigendum : Development Of Distribution Infrastructure In Tawang District Of Arunachal Pradesh Under The Revamped Reforms-Based And Results-Linked, Distribution Sector Scheme
Open Tender
Indian
Arunachal Pradesh
tawang
27-09-2023

Tender Details

Development Of Distribution Infrastructure In Tawang District Of Arunachal Pradesh Under The Revamped Reforms-Based And Results-Linked, Distribution Sector Scheme

Corrigendum Details

Sr No CorrigendumDate Corrignedum CorrigendumType NewSubmissionDate
1 28-Aug-2023 corrigendum for date extension Date 20-09-2023
2 30-Aug-2023 Revised Minutes of Meeting Other 20-09-2023
3 12-Sep-2023 AAA Conductor Size Other 20-09-2023
4 18-Sep-2023 RDSS Date Extension Date 27-09-2023

Key Value

Document Fees
INR 17700 /-
EMD
INR 7525803.0 /-
Tender Value
Refer document

BOQ Items

Name of Work: development of distribution Infrastructure under reforms based and result linked distribution sector scheme (RDSS).
Sl. No. Item Description
1Supply as per TS, scope of work and approved drawings
2Manufacture and supply of 11 KV overhead line as per technical specification, approved drawings and scope of work
39 M long Steel Tubular 410 SP-32 conforming to IS2713(Part 1)1980
410M long Steel Tubular poles 410 SP-44 conforming to IS2713(Part 1)1980
5Support for LT overhead Line as per technical specification, approved drawings and scope of work.
6Designing, Fabrication and supply of 7.50 M Long off 410 SP death 9 it"s steel tubular poles confirming to IS 2713 (Part 1 ) 1980
7Manufacture and supply of Pre-fabricated galvanised steel items (zinc coating 610gms/sqm), like V cross arm, top clamp, DC cross arm, bracket, clamps, cross bracings, bracings, strain plate, guarding channels, back clamp etc made of GS Channels, GS angle , GS flatsof given sizes for over head structures as per technical specification, approved drawings and scope of work.
811 KV, 3 Wire, 2.8 m long cross arm made of MS Channel of size 125x 50 x 6 mm complete etc.
911 KV "Y" - Type cross arm made of Angle of size 50 x 50 x 6 mm in radial structure of 3 arms of 0.8 m long 120° apart complete etc.
10Angle bracing set 3.1 m long of size 65 x 65 x 6 mm complete with accessories nut / bolts etc.
11MS Channel of size 100 X 50 X 4.7 mm for Air Break switch top bracket transformer mounting and Drop Out fuse (8 X 2 = 16 m) i/c nuts and bolts.
12Manufacturing and supply ofLT Aerial Bunched cable assesories
13Suspension clamp assembly with eye hook and 2 nos MS Half Round clamp for suspending eye-hook with 3 nos nuts and bolts in complete set
14Dead end clamp with eye hook and 2 nos MS Half Round clamps for suspending eye-hook with 3 nos nuts and bolts in complete set
15Insulated connectors with covers
16Manufacturing and supplying of GI earth clamps.
173Ph Distribution Box with associate accessories complete to connect household services as required.
18Manufacture and supply of Stay Set (Galvanised) with 50x8 mm stay clamp, stay insulator (2 Nos.), MS anchor plate (300mmx300mmx5mm), nut bolts, 2 Nos turn-buckles, 1.8 m long, 18 mm diameter solid GS stay rod & 7/3.15 mm dia GI strandedwire complete as per technical specification, approved drawings and scope of work.
19Manufacture and supply of Insulator and hardware as per technical specification, approved drawings and scope of work.
2011 KV polymer Disc insulator 45 KN
2111 KV polymer Disc insulator 45 KN hardware fittings
2211 KV PolymerPin Insulators with GI PIN
23Manufacture and supply of Earthing arrangement as per technical specificatons,approved drawings and scope of work.
2440 mm dia., 4.5m long GI pipe earth electrode with GI wire for pole earthing including salt charcoal and other accessories complete
258 SWG GI wire
2611 KV, 3.1 m long Guard Bracket made of Channel of size 100 x 50 x 6 mm Complete etc
27Copper plate earthing of transformer CBS & Battery charger including cost of copper plate size 600 X 600 X 6 mm & copper strip of size 25 X 4 mm i/c salt, charcoal etc. as required.
28FOR 100KVA : Supplying, fitting and fixing of chain link fencing of SWG GL wire (50X50X5mm mesh) i/c corner and end post with MS angle of size 50X50X5mm and length not less than 1800mm intermideate post of MS angle of size 40X40X5mm and D length not less than 1800mm i/c supplying, fittings and fixing of hook, eyebolt with nuts, staples bolts etcas required with 3 horizontal line of GL wire 10swg at top middle and bottom and with one vertical line to each fencing tight and erect complete i/c the cost of primer, painting of MS angle iron post in PCC base etc and two cot of Al pain on foundation of cost with PCC works of 1:2:4 CC as per approved drawing.
29FOR 100KVA : Fabrication and Supply of standard size MS Gate as per approved drawing
30Manufacture and supply of ACSR Conductors of following sizes with Jointing sleeves, binding materials, PG clamps, bi-metallic clamp, hardware etc for overhead line and jumpers as required as per technical specification, approved drawings and scope of work
316/2.59 + 1/2.59 mm (30 mm² Al. Area) - Weasel
32Manufacturing and supply LT Aerial Bunched Cable 1100 Volts (3.5 Core) of size
33AERIAL BUNCHEDCABLE 3 X 50 SQ.MM+1x25 SQ. MM.+1x16 SQ. MM.
34AERIAL BUNCHEDCABLE 3 X 35 SQ.MM.+1x25 SQ. MM.+ 1x16 SQ. MM.
35AERIAL BUNCHEDCABLE 3 X 120 SQ.MM. + 1x70 SQ. MM. +1x16 SQ. MM.
36AERIAL BUNCHEDCABLE 3 X 95 SQ.MM. + 1 x50 SQ. MM.+ 1x16 SQ. MM.
37AERIAL BUNCHEDCABLE 3 X 70 SQ.MM.+1 x50 SQ. MM.+ 1x16 SQ. MM.
38Manufacture and supply of Safety Alert System as per technical specification, approved drawings and scope of work
39Danger Plate of size 250 mm x 200 mm of thickness 3 mm. ( 11000V)
40Danger Plate of size 250 mm x 200 mm of thickness 3 mm. ( 415V)
41Anti climbing devices with G. I. thornwire / Barbed wires.
42Manufacture and supply of Painting and Finishing Work as per technical specification, approved drawings and scope of work
43Supply & Painting with 2 coats of red oxide paint& 2 coats of paints on poles / equipment / metal surfaces on full rate basis.
44Manufacture and supply of Augmentation of Distribution Transformer Substation using new outdoor type, oil immersed, naturally cooled pole mounted/ floor mounted (100KVA) distribution transformer (i/c transformer foundation materials) with all accessories as per scope of work, approved drawings and specifications:
4511/0.433 KV Distribution Transformer 25 KVA 3 phase Aluminium wound DTR
4611/0.433 KV Distribution Transformer 63 KVA 3 phase Aluminium wound DTR
4711/0.433 KV Distribution Transformer 100 KVA 3 phase Aluminium wound DTR
48Manufacture and supply of Designing Manufacturing & supply of weather proof pole mounted LT Pannel Board with adequate ratings of MCCBs/RCBs, space duly provided or mounting DT Energy & service connection distribution board within the same panel.
49Manufacture and supply of 11 KV Distribution Class Lightening Arrester for DT as per technical specification, approved drawings and scope of work.
50Manufacture and supply of 11 KV, 50 HZ Air Break Switch conforming to IS : 9920 (Pt - I to IV) with rated voltage 12 KV & rated normal current shall be 400 Amps. Provided with bimettallic connector on the incomming side to accommodate ACSR of sizes 20, 30, 50 Sqmm on the outgoing side.
51Manufacture and supply of Outdoor, drop out expulsion type of 11 KV drop out fuse suitable for insullation in 50 HZ, 11 KV distribution system confroming to IS : 9385 (Pt - I to III) with rated voltage shall be 12 KV & rated currentshall be 400Ampsprovided with a suitable arrangement these on 100 X 50 X 6 MM channel cross arm.
52Manufacture and supply of 1.1 KV XLPE Aluminium Conductor, Stranded, armoured cable for connection of transformer LV bushing to Distribution Box and Distribution box to overhead line as per Scope of work, technical specification and approved drawings:
533.5CX35 sqmm aluminium conductor cable
543.5CX50 sqmm aluminium conductor cable
553.5Cx120 sqmm aluminium conductor cable
56Signboard clearly representing about the work, date of commissioning, estimated cost, scheme, employer"s details and rating in KVA. (Specification same as Danger Plate of size 250 mm x 200 mm of thickness 3 mm.)
57Manufacturing, supplying and installation of alluminium PG clamp
58Manufacture and supply of AAA Conductors of following sizes with Jointing sleeves, binding materials, PG clamps, hardware etc for overhead line and jumpers as required as per technical specification, approved drawings and scope of work
59AAA Covered Conductors, 120sqmm
6011KV Wedge Connector for bare to CC connection
61IPC(for connecting 70 sqmm CC to CC)
62Erection, testing and Commissioning as per Technical Specification /scope of work
63Excavation of pole pit (of depth 1/6th of pole length) in all kind of soil/rock & Erection of following types of poles for 11 KV overhead line by providing and installing danger plate, anti-climbing devices (barbed wire), earthing material (coil and 8SWG GI wire), pole numbering including cement concrete foundation or refilling by bolders using cement concreting foundation 1 part cement, 3 part sand, 6 part 40 mm size stone aggregate chips (1:3:6) or/and 200 mm average size bolders mixed with excavated earth , Top muffing etc as per scope of work, approved drawings and specifications:
649 M long Steel Tubular poles 410 SP-32
6510 M long Steel Tubular poles 410 SP-44
66STEEL TUBULAR POLES as per ISS.
67Erection of7.5 m long of 410 SP-09 Steel single pole including excavation ofpitsin all kind of soil/rock complete foundation (including supply of foundation materials) , Top muffing ,fixing of cross arm , pole top bracket, anticlimbing device and other accessories complete in all respectas per TS.
68Erection, testing & commissioning of pre-fabricated galvanised steel items like V cross arm, top clamp, DC cross arm, bracket, clamps, cross bracings, bracings, strain plate, guarding channels, back clamp, etc made of GS Channels, GS angle, GS flats of given sizes for over head structures and GS nuts, bolts & washers including painting by red oxide & aluminium paint as per technical specification, approved drawings and scope of work.
6911 KV "Y" - Type cross arm made of Angle of size 50 x 50 x 6 mm in radial structure of 3 arms of 0.8 m long 120° apart complete etc.
70Angle bracing set 3.1 m long of size 65 x 65 x 6 mm complete with accessories nut / bolts etc.
71Erection ,Testing and Commisioning of LT line with following LT Aerial Bunched Cable 1100 Volts (3.5 Core) of size:
72AERIAL BUNCHED CABLE 3 X 50 SQ.MM+1x25 SQ. MM.+1x16 SQ. MM.
73AERIAL BUNCHED CABLE 3 X 35 SQ.MM.+1x25 SQ. MM.+ 1x16 SQ. MM.
74AERIAL BUNCHED CABLE 3 X 120 SQ.MM. + 1x70 SQ. MM. +1x16 SQ. MM.
75AERIAL BUNCHED CABLE 3 X 95 SQ.MM. + 1 x50 SQ. MM.+ 1x16 SQ. MM.
76AERIAL BUNCHED CABLE 3 X 70 SQ.MM.+1 x50 SQ. MM.+ 1x16 SQ. MM.
77LT Aerial Bunched Cable assesories
78Erection of GI earth clamps.
79Erection of suspension clamp, Dead end assembly with eye hook , insulated connector and others miscellaneous items required for completion of works
80Earthing arrangement as per technical specificatons,approved drawings and scope of work.
81Excavation, erection, testing & commissioning of 40 mm dia., 4.5 m long GI pipe earth electrode with GI wire for pole earthing , Charcoal, Salt and other accessories complete
82Erection of 8 SWG GI wire for earthing and guarding by providing GI nut, bolts & washers, turn buckle etc
83Erection of 11 KV, 3.1 m long Guard Bracket made of Channel of size 100 x 50 x 6 mm Complete etc
84Copper plate earthing of transformer CBS & Battery charger including cost of copper plate size 600 X 600 X 6 mm & copper strip of size 25 X 4 mm i/c salt, charcoal etc. as required.
85FOR 100KVA : Fabrication and Supply of standard size MS Gate as per approved drawing
86Erection of complete stay set with GI stay wire (7x3.15 mm dia), binding of stay wire, by providing Guy stay insulator (2 Nos.) and 0.2 cmt concreting 1 part cement, 3 part sand, 6 part 40 mm size stone aggregate chips (1:3:6) as per technical specifications, approved drawings and scope of works.
87Laying out, tensioning, binding of conductor and tightening of stays and stringing, testing and commissioning of ACSRConductor of following sizes including jointing sleeves, helical formed fittings, jumpering and by providing & erecting PG Clamps etc as required as per approved drawings, scope of work and technical specifications
886/2.59 + 1/2.59 mm (30 mm² Al. Area) - Weasel
89Painting and Finishing Work
90Painting with 2 coats of red oxide paint& 2 coats of alluminium paints on poles / equipment / metal surfaces on full rate basis.
91Jungle clearance thick and thin including cutting, uprooting and removing trees more than 20cm upto 61 cm girth, filling up and levelling the hollows of dugs roots, stacking the useful materials and disposing of rubbish upto a distance 15m outside the periphery of the area cleared (Girth to be measured 1.22m above ground level and at ground level in case of bamboo or cane clumps).
92Erection, Testing and Commissioning of pole mounted/floor mounted (100KVA) Distribution Transformer (i/c transfomer foundation materials) with all accessories as per scope of work, approved drawings and specifications:
9311/0.4 KV Distribution Transformer 25 KVA 3 phase Aluminium wound DTR
9411/0.4 KV Distribution Transformer 63 KVA 3 phase Aluminium wound DTR
9511/0.4 KV Distribution Transformer 100 KVA 3 phase Aluminium wound DTR
96SAFETY ALERT SYSTEM
97Manufacturing, fabrication and supply of danger plate made of mild steel sheet of atleast 1.6 mm thick and vitreous enameled white, with letters, figures and the conventional skull and cross-bones in signal red colour on the front side for -
98Danger Plate of size 250 mm x 200 mm of thickness 3 mm.(415V)
99Danger Plate of size 250 mm x 200 mm of thickness 3 mm.(11000V)
100Anti climbing devices with G. I. thornwire / Barbed wires.
101Stringing of AAA Covered Conductor as per approved sagging including installation of 11kv 45KN disc insulators with strain hardware/11KV 45KN pin insulators with GI pin, hardware fittings, conductors accessories, jumpering arrangement etc. This shall also includes errection of PG clamp and connectors, jointing sleevesetc. as required complete in all repsect as per TS.
102AAC Conductor 120 Sqmm
Disclaimer :