Tender For Repair, Maintenance And Overhauling Of Dg Sets, Battery Charger Including Replacement Of Worn Out Parts And Connected Controlling Accessories At Mil Station Agartala, agartala-Tripura

Military Engineer Services-MES has published Tender For Repair, Maintenance And Overhauling Of Dg Sets, Battery Charger Including Replacement Of Worn Out Parts And Connected Controlling Accessories At Mil Station Agartala. Submission Date for this Tender is 31-08-2023. Battery Chargers Tenders in agartala Tripura. Bidders can get complete Tender details and download the document.




Tender Notice

39007389
Corrigendum : Tender For Repair, Maintenance And Overhauling Of Dg Sets, Battery Charger Including Replacement Of Worn Out Parts And Connected Controlling Accessories At Mil Station Agartala
Open Tender
Indian
Tripura
agartala
31-08-2023

Tender Details

Tender For Repair, Maintenance And Overhauling Of Dg Sets, Battery Charger Including Replacement Of Worn Out Parts And Connected Controlling Accessories At Mil Station Agartala

Corrigendum Details

Sr No CorrigendumDate Corrignedum CorrigendumType NewSubmissionDate
1 19-Aug-2023 Bid Auto Extn Corrigendum Bid Auto Extn Corrigendum 26-08-2023
2 26-Aug-2023 Bid Auto Extn Corrigendum Bid Auto Extn Corrigendum 31-08-2023

Key Value

Document Fees
INR 500 /-
EMD
INR 18540.0 /-
Tender Value
INR 9.27 Lakhs /-

BOQ Items

NAME OF WORK : REPAIR, MAINT AND OVERHAULING OF DG SETS, BATTERY CHARGER INCLUDING REPLACEMENT OF WORN OUT PARTS AND CONNECTED CONTROLLING ACCESSORIES AT MIL STN AGARTALA
Sl. No. Item Description
1Schedule"A" Part-I: E/M works
2Dismandling and supply and fixing forairfilterelement suitable for 100 KVA Crompton GreavesDG set , all as specified and directed .
3All as per item No.1.00 here-in-before but for 82.5 KVA
4All as per item No.1.00 here-in-before but for 45 KVA
5All as per item No.1.00 here-in-before but for 30 KVA
6Dismandling , taking out complete engine head assembly of 45 KVA CROMPTON GREAVES ,4YDA,MK-3from engine block for replacement of unserviceable parts/ spares/accessories/mounting and reassembling after replacement complete and testing all as specified and directed. Note : New parts/ spares /acessories / mounting shall be paid seperately as supply only under relevant items here in below
7Supply only "O" ring suitable for 45 KVA ,CG ,4 YDA DG set
8Supply onlycylinder head Gasket suitable for 45 KVA ,CG ,4 YDA DG set
9Supply only piston with piston ring set and gudgen pin completesuitable for 45 KVA ,CG ,4 YDA DG set
10Supply only cylinder linersuitable for 45 KVA ,CG ,4 YDA DG set
11Supply only small end and bigend bearing suitable for 45 KVA ,CG ,4 YDA DG set
12Dismandling , taking out complete engine head assembly of 30 KVA KIRLOSKAR,RB-33from engine block for replacement of unserviceable parts/ spares/accessories/mounting and reassembling after replacement complete and testing all as specified and directed.Note: New parts/ spares /acessories / mounting shall be paid seperately as supply only under relevant items here in below
13Supply only "O" ring suitable for30 KVA KIRLOSKAR ,RB-33,DG set
14Supply onlycylinder head Gasket suitable for 30 KVA KIRLOSKAR ,RB-33 DG set
15Supply only piston with piston ring set and gudgen pin completesuitable for 30 KVA KIRLOSKAR ,RB-33,DG set
16Supply only cylinder linersuitable for 30 KVA KIRLOSKAR ,RB-33 ,DG set
17Supply only small end and bigend bearing suitable for 30 KVA KIRLOSKAR ,RB-33 DG set
18Drain out existing old engine oil, cleaning sump by K-oil and supply and filling new engine oil 20W 40 Grade Castrol CRB all as specified and directed.
19Dismandling and supply and fixing PVC ,armoured fuel pipe from tank to DG Set (Over flow and incoming both) in various installation as per sample all as specified and directed.
20Disconnect ,removing burnt carbon brush with hiolder assembly and supply and fixing new carbon brush with hoder assembly suitable for "Kirloskar " 30 KVA ,3 Ph ,4 wire 440 Volt,RB -33 ,DG set all as specified and directed.
21Cleaning entire structure of crane 2 to 5 Ton capacity .Remove all grease and oil from crane parts ,including railing ramp etc.Painting of crane with existing paint colour of two coat overredoxide primer complete all as specified and directed.
22M & L for changing of gear oil of grane Type EP-320 thick level (Make : Monex) including cleaning of gear box by E /oil complete all as specified and directed.
23Disconnecting ,nut and bolt ,taking out existing antivibrationgenerating mounting pad , supply andfixing of new antivibration generating mounting pad suitable to resist withstand the load of 30/45/82.5KVA DG setconfirm to ISOcertified , all as specified and directed .
24Dismandling and supply and fixing for flexible Asbestos rope of 80 to 150mm diainsulation into DG Setexhaust pipe including taking down existing burnt rope all as specified and directed .
25Taking down DG set from existing platform by diconnecting electrical cables , Battery terminals, exhaust silencer pipes ,earthing connectins etc and shifted to safe place . After raising platform , floors (separate measurable items), re- installation to DG set with all connected accesssories , testing and commissioing etc all as secified and directed ofDG set of Kirloskar/Crompton 45 KVA/30 KVA .
26Supply & Fixing for Offload Changeover Switch, AC 21 (side handle), 200 Amp, 415 volts, 50 Hz in sheet enclosure with side handle including making incoming and outgoing connections complete all as specified and directed
27Supply & Fixing for Offload Changeover Switch, AC 23 (side handle), 100 Amp, 415 volts, 50 Hz in sheet enclosure with side handle including making incoming and outgoing connections complete all as specified and directed
28Supply & Fixing forChange over Switch ,four pole 63 Amp, 415 volts, 50 Hz in sheet enclosure with side handle ,conforming to IS/IEC 60947-1&3including making incoming and outgoing connections complete all as specified and directed
29Disconnect ,and supply and fixingfuel filter element suitable for following make and capacity of DG set , all as specified and directed .
30Kirloskar , 45 KVA,HA 49 4TC
31Kirloskar ,45 KVA,RB-44
32Kirloskar ,30 KVA,RB-33
33Kirloskar ,30 KVA,3R104D
34C Greaves ,30 KVA ,3YDA MK-3
35C Greaves ,45 KVA ,4YDA MK-3
36C Greaves ,100 KVA ,4YDA MK-3
37Disconnecting nuts and bolts ,taking down existing unserviceable self starterand supply and fixing new self starterconsisting of starter pinion ,gear spindle ,coupling housing , pre-tension spring completesuitable to start 45 KVA Crompton GreavesDG Set and having operating voltage 12 V,DC including all fixing arrangementall as specified and directed .
38Disconnecting nuts and bolts ,taking down existing unserviceable self starterand supply and fixing new self starterconsisting of starter pinion ,gear spindle ,coupling housing , pre-tension spring completesuitable to start 30 KVAKirloskarDG Set and having operating voltage 12 V,DC including all fixing arrangementall as specified and directed .
39Disconnect ,and supply and fixing lubricant oil filterelement suitable for following make and capacity of DG set , all as specified and directed .
40Kirloskar , 45 KVA,HA 49 4TC
41Kirloskar ,45 KVA,RB-44
42Kirloskar ,30 KVA,RB-33
43Kirloskar ,30 KVA,3R104D
44C Greaves ,30 KVA ,3YDA MK-3
45C Greaves ,45 KVA ,4YDA MK-3
46C Greaves ,100 KVA ,4YDA MK-3
47Supply & FixingMCCB four pole 200 Amp, 415 volts, 50 Hz, fixed thermal and fixed magnetic setting and breaking capacity 35 KA/26KA conforming to IS/IEC:60947-2,including making incoming and outgoing connections complete all as specified and directed
48Supply & FixingMCCB four pole 150 Amp, 415 volts, 50 Hz, fixed thermal and fixed magnetic setting and breaking capacity 25 KA/26KA conforming to IS/IEC:60947-2,including making incoming and outgoing connections complete all as specified and directed
49Supply & FixingMCCB four pole 100 Amp, 415 volts, 50 Hz, fixed thermal and fixed magnetic setting and breaking capacity 25 KA/26KA conforming to IS/IEC:60947-2,including making incoming and outgoing connections complete all as specified and directed
50Supply & Fixing fully automatic star-Delta starter of capacity 25 HP, 3 Phase, 415 volt including making incoming and outgoing connections complete all as specified and directed
51Supply & FixingMCB triple pole 63 Amp, 415 volts, 50 Hz, "D" series 16 KA including making incoming and outgoing connections complete all as specified and directed
52Dismandling of fuel injectors from DG set ,segregation for serviceable and worn out parts ,carry out repair and replacement of worn out parts such as injector nozzle ,Oring ,injector cup,injector barrel,injector plunger , including pressure testing and fiiting to engine and testing the engine for proper functioning etc all as specifief and directed .
53Kirloskar , 45 KVA,RB-44 (82.5)
54C Greaves ,45 KVA ,4YDA MK-3
55Kirloskar ,30 KVA,RB-33
56Disconnecting the Radiator complete from DG set , taking into workshop for cleaning fines by cleaning agent , brazing into damaged fines , water circulation tubesetc,. Taking back to installation ,refixing into original position including supply and replacement of rubber hose pipes complete set ofKirloskar make 45/30/100 KVA DG set all as specified and directed.
57Dismandling and supply and fixing fan belt suitable forfollowing DG Set all as Specified and directed .
58Kirloskar , 45 KVA,HA 49 4TC
59Kirloskar ,45 KVA,RB-44
60Kirloskar ,30 KVA,RB-33
61Kirloskar ,30 KVA,3R104D
62C Greaves ,30 KVA ,3YDA MK-3
63C Greaves ,45 KVA ,4YDA MK-3
64C Greaves ,100 KVA ,4YDA MK-3
65Excavation in trenches not exceeding 1.5 mtr wide and not exceeding 1.5 mtr in depth for laying of pipe and getting out in soft/loose soil all as directed and specified.
66Removing excavated material not exceeding 50 mtr and depositing where directed at a level not exceeding 1.5 mtr above the starting point.
67Returning, filling in, including spreading, leveling, watering and well ramming in layers not exc. 25 cm all as specified and directed.
68M&L for sand cushioning to PVC/XLPE cable with river sand and punning to provide required cushioning to under ground cable all as specified and directed.Note :-Only punned thickness shall be taken for measurement
69Supplying and Laying sub class "B" brick for protection of LT under ground cable laid dry, flat abutting each other with gaps between adjacent brick not exceeding 10mm after taking out the old unserviceable cable protection brick all as specified and directed.
70M&L Heavy duty armoured LT U/G cable of size 50 Smm 3.5 Core ,1100v grade,PVC insulated,PVC sheathed mutistranded aluminium cable passing through pipe/trench/cable duct/fixed on wall by proper size of GI clamps with nut and bolts etc ,making good the disturbed surface complete.
71M&L Heavy duty armoured LT U/G cable of size 70 Smm 3.5 Core ,1100v grade,PVC insulated,PVC sheathed mutistranded aluminium cable passing through pipe/trench/cable duct/fixed on wall by proper size of GI clamps with nut and bolts etc ,making good the disturbed surface complete.
72S&F GI steel tubing light grade for protection of cable on poles, under road crossing etc of 40 mm bore.
73M&L for Earthing complete in replacement with galvanised iron mild steel earth plate electrode 60 cm x 60 cm x 6.3mm thick burried directly in ground vertically to a depth not less than 2.25 metre below ground level with top edge of earth plate at a depth of not less than 1.5 metre below normal ground level, connected to glavanised earth lead of GI strip of size 25mm x 4mm by means of GI Bolts, Nuts, check nuts and washers of the earth and thimbles and other end of the earth strip connected to earthing test point and protected by galvanised iron pipe light grade 40mm dia from earth plate to Panel and installations and water pipe 20mm dia GI medium grade raised upto a level of 50cm above ground level with plug at top, earthing pit in PCC (1:3:6) type C-1 RCC pre-cast (1:2:4 typeB-1) cover slab of 100 mm thick using 8.00mm dia TMT bars @ 100mm C/C as reinforcement, 20 mm dia GI pipe medium grade for watering pipe, wire mesh, funnel and providingcharcoal or coke and salt in alternative layersof 15 cm includingnecessary earth work in soft/loose soil, returning, refilling and removing ofsurplus soil to a distance not of MES Schedule Part-I of SSR-2009 exceeding 50 mtr testing complete all as shown in electrical plate No-3 as specified and directed.
74M&L for Earth continuity conductor or main earthing lead fixed to wall on batten or recess or chases or buried in ground or drawn in conduit/pipe or fixed to ploes or any other indicated situation for loop earthing etc. as required 32 x 6 mm Galvanaised iron strip complete all as specified and directed.
75All as per item No.36.00 here-in-before but for 25 x 4mm GI Strip.
76NOTES :- 1.The amount of schedule of credit shall be deducted from the total of this BOQ for arriving at contract sum. 2.Unless otherwise specified the rates for PCC shall deemed to include the cost of formwork shuttering etc, required for complete and proper execution of the work. Refer Schedule "A" notes for details.
Disclaimer :
We takes all possible care for accurate & authentic tender information, however Users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender.
Tell us about your Product / Services,
We will Find Tenders for you

Copyright © 2024 · All Rights Reserved. Terms of Usage | Privacy Policy

For Tender Information Services Visit : TenderDetail