Providing Electro-Mechanical Equipments And Allied Works For Arsenic Removal Plant At Dakshin Jhitkapota Zone-I Phase-Ii Piped Water Supply Scheme, Block Krishnagar-I, Dist. Nadia Under Emd, Phe Dte, Kolkata-West Bengal

Public Health Engineering Department-PHED has published Providing Electro-Mechanical Equipments And Allied Works For Arsenic Removal Plant At Dakshin Jhitkapota Zone-I Phase-Ii Piped Water Supply Scheme, Block Krishnagar-I, Dist. Nadia Under Emd, Phe Dte. Submission Date for this Tender is 23-08-2023. Electromechanical Machinery Tenders in Kolkata West Bengal. Bidders can get complete Tender details and download the document.




Tender Notice

38981545
Providing Electro-Mechanical Equipments And Allied Works For Arsenic Removal Plant At Dakshin Jhitkapota Zone-I Phase-Ii Piped Water Supply Scheme, Block Krishnagar-I, Dist. Nadia Under Emd, Phe Dte
Open Tender
Indian
West Bengal
Kolkata
23-08-2023

Tender Details

Providing Electro-Mechanical Equipments And Allied Works For Arsenic Removal Plant At Dakshin Jhitkapota Zone-I Phase-Ii Piped Water Supply Scheme, Block Krishnagar-I, Dist. Nadia Under Emd, Phe Dte-2 Supply, Delivery And Storage At Site Of Horizontal Split Casing Centrifugal Pumping Machineries With Baseplate, Flexible Coupling, Coupling Guard, Foundation Bolt Etc. Having The Following Specification And As Pernit. : ( Pumps Suitable For Plc Operated Unmaned Operation Facility ) ( For Pumping Water From Cwr To Ohr ) Discharge :- 95M3 Per Hour Generated Head :- 40 Mwc H-Q-P Curve Of Pumps In Test Bed Has To Be Submitted During The Delivery. 3 Supply, Delivery And Storage At Site Horizontal Foot Mounted Induction Motor Suitable For The Pump Duty Mentioned Above ( Item No- 1 ) With Adequate Margin As Specified In The Nit. Routine Test Certificate Of Induction Motor Has To Be Submitted During Delivery 4 Supply, Delivery And Storage At Site Of Monoblockvvacuum Pumping Machinarywith The Following Specification And As Pernit. : A ) Vacuum : Upto 600 Mm Of Hg B ) Air Flow Rate : 1.8 To 20.5 M3 / Hr 5 Supply, Delivery And Storage At Site Lift Type 150 Mm Foot Valve Combined With Stainer As Per Is : 4038 Pn-0.6 And As Per Detail Given In The Nit . :-N.B. : Test Certificate To Be Produced For Each Valve ( At Suction Side Of Pump ) 6 Supply, Delivery And Storage At Site Of Ci Doble Flanged Single Door Swing Check125 Mm Dia N.R.Vas Per Is : 5312, Part-I, Pn-1.0 And As Per Detail Given In Nit. :-N.B. : Test Certificate To Be Produced For Each Valve. ( At Delivery Side Of Pump ) 7 Supply, Delivery And Storage At Site 125 Mm Diacast Iron Actuator Operated Wafer Type Butterfly Valvegenerally Conforming To Is:13095 And Pn-1.0. And As Per Detail Given In Nit. :-N.B. : Test Certificate To Be Produced For Each Valve ( At Delivery Side Of Pump ) 8 Supply, Delivery And Storage At Site 125 Mm Diadouble Flanged Cast Iron Manually Operated Non-Rising Spindle Sluice Valve Generally Conforming Tois:14846 Pn-1.0.And As Per Detail Given In Nit. :-N.B. : Test Certificate To Be Produced For Each Valve. ( At Common Delivery Header ) 9 Supply, Delivery And Storage At Site 80 Mm Diacast Iron Kinetic Double Orifice Air Released Valve As Per Relevant Is, Pn-1.0.And As Per Detail Given In Nit. :-N.B. : Test Certificate To Be Produced For Each Valve. ( At Common Delivery Header ) 10 Supply, Delivery And Storage At Site Ms Dismantling Joint Dn 125Mm Pn 1.0 ( For Delivery Side & Common Header Ofpump ) 11 Supply, Delivery And Storage At Site Bourdon Type Pressure & Compound Gauges, 150 Mm Dia Cast Aluminium Dial With , Ss Internal, Dn 15 Gi Impulse Line With Three Way Cock. 12 A ) Pressure Guages ( 0 - 15 Kg / Cm2 ) 13 B ) Compound Guages ( +1 To -1 Kscg ) 14 Supply, Delivery And Storage At Site Of 150 Mm Dia , Thickness 5.4Mm And 125 Mm Dia 5.4 Mm Thick Ms Black Pipe Conforming To Is:3589 Gr.330 ( For Suction, Delivery & Delivery Header ) Along With Necessarybends, Fittings Viz. Flanges, Bolts, Nuts, Gaskets , Eccentric Reducers , Concentric Enlarger Etc. As Reqd. To Make The Installation Complete In All Respect Andas Pernit. 15 Supply Delivery And Storage At Site Of Ultrasonic / Radartype Continuous Level Measuring Unit With Provision Of 4 To 20 Ma Analogue Signal, Indicator And Recorder For Continuous Level Monitoring As Well As 5 Nos. Relay Out Put For Sensing High, Low, Low - Low Level In Suction Sump As Per Specification Given In Nit. 16 Supply, Delivery And Storage At Site20 Mm Dia, G.Ipipes ( Medium Duty ) , Water Storage Pvc Tank , Bends, Sockets, Tees, Fittings, And Other Specials, Gaskets , Solenoide Valve , Gate Valve For Auto & Manual Operation Etc. As Reqd. To Make The Piping Arrangement Of Vacuum Pumpcomplete In All Respect As Pernit. ( For Priming Arrangement ) 17 Supply, Delivery And Storage At Site 2 Mm. Thick Crca Sheet Steel Enclosed Cubical Type Indoor Floor Mounted415 Volt Mccpanelhaving Required Feeders With Plc As Per Specification Given In Nit. 18 Supply, Delivery And Storage At Site 2 Mm. Thick Crca Sheet Steel Enclosed Cubical Type Indoor Wall Mounted415 Volt Power Distribution Board ( Pdb ) Having Required Feedersas Per Specification Given In Nit. 19 Supply, Delivery And Storage At Site 1.1 Kv Grade50 Mm2 3½Core Xlpe Insulated Cupper Armoured Cable As Per Technical Specification Of Nit. ( From Wbsedcl End Cut Out To Pdb Panel ) ) 20 Supply, Delivery And Storage At Site 1.1 Kv Grade70 Mm2 3½Core Xlpe Insulated Aluminiun Armoured Cable As Per Technical Specification Of Nit. ( For Pdb Panel To Airp Mcc Panel ) 21 Supply, Delivery And Storage At Site 1.1 Kv Grade 50 Sq. Mm. Xlpe Insulated Aluminiun Armoured Cable As Per Technical Specification Of Nit. ( For Pdb To Low Lift Mcc Panel . ) 22 Supply, Delivery And Storage At Site 1.1 Kv Grade 16 Sq. Mm.3Core Xlpe Insulated Aluminiun Armoured Cable As Per Technical Specification Of Nit. ( For Mcc Panel To Motor ) 23 Supply, Delivery And Storage At Site1.1 Kv Grade 2.5 Sq. Mm.12Core Pvc Insulated Armoured Copper Controlcable As Per Technical Specification Of Nit. ( Formcc Panel To Actuator. ) 24 Supply, Delivery And Storage At Site1.1 Kv Grade 2.5 Sq. Mm.2Core Pvc Insulated Armoured Copper Controlcable As Per Technical Specification Of Nit. ( For Solenoid Valve Connection ) 25 Supply, Delivery And Storage At Site1.1 Kv Grade 4 Sq. Mm.2Core Pvc Insulated Armoured Coppercable As Per Technical Specification Of Nit. ( For Vacuum Pump Connection ) 26 Earthing & Lightning Protection For Pump House And Electrical Installation As Per Iss And Ie Rules And As Per Technical Specification Of Nit. ( Earth Pit 2 Nos+ 2 L / A ) 27 Supply, Delivery At Site And Storeage Of Gi Perforated Cable Tray At Pump House For Laying Of Incoming & Outgoing Power And Control Cables To And From Mcc Panelhaving Proper M.S. Structural Support As Per Nit Specification And Direction Of Eic. 28 Supply Delivery At Site And Storage Of Illumination Arrangement Like Suitable Size Wire, Switch , Switch Board , Tube Light Fitting , Exhaust Fan , Ceilling Fan , Led Outdoor Fixturecomplete As Per Specification Of Nit. 29 Supply Delivery At Site And Storage Of Safety Equipment Like Suitable Capacity Fire Extinguisher , Sand Bucket , Fire Bracket, Rubber Mats, Shock Treatment Chart And First Aid Box, Chair , Table, 415 Volt Danger Board Complete As Per Specification Of Nit. 30 Supply And Delivery At Site And Storage Of Suitable Capacity Power Corection Arrangement As Per Specification Of Niet 31 Supply And Delivery At Site And Storage Of Suitable Capacity Disinfection Arrangement With Flow Rate 200 Lph As Per Specification Of Niet 32 Part-B 33 Installation Of All Items As Mentioned In Sl.No.1 To 28 ( Part-A ) Including Construction Of Pump Foundations, Pipe Supports, Valve Supports, Laying Of Cables With Necessary Jointing Materials, Earthing Arrangement Of Motors, Starters, Including Supply Of All Erection Items Viz. Rubber Gaskets, Nuts & Bolts Etc., Including Cost Ofwelding Etc. As Required For Complete Installation Including Making Slope Of Floor And Arrangement Of Removing Gland Leckage Wateras Per Hydraulic Standard & Ie Rules In Compliance With Specification Of Nitand Upto Entire Satisfaction Of Eic. 34 Painting Of The Installation ( Viz.Pumps, Valves, Pipe Lines Etc.By Two Coats Of Epoxy Paint ( Colour To Be Decided By Eic ) Over A Coat Of Primer As Per Nit Specifiaction & Direction Of Eic. 35 Testing & Commissioning Of The Entire Installation I.E.Pumps, Motors, Valves Etc. As In Part A ( Sl No. 1To 28 ) As Per Direction And To The Entire Satisfaction Of E.I.C. 36 Operation And Maintenance Of The Entire Installation In High Lift Pumping Stations On 24 Hrs. Basis Including Guarding For A Period Of 90 Days Are To Be Provided With Supply Of Skilled, Semi-Skilled And Un-Skilled Personnel Including Watch And Ward Personnel From The Date Of Commissioning. During Maintenance Period Supply Of All Consumable Materials Sundrys And Lubricants Are To Be Supplied. Charges Of Electrical Energy During Maintenance Period Will Be Borne By The Department. 37 Supervision Charges For Electrical Installation By Licensed Electrician As Per Ie Rules, 1956 Read With Latest Amendments With Overhead Expenditures

Key Value

Document Fees
Refer document
EMD
INR 107100.0 /-
Tender Value
INR 53.53 Lakhs /-

BOQ Items

Name of Work:Providing Electro-MechanicalEquipments and Allied Works for Arsenic Removal Plant at DAKSHIN JHITKAPOTA ZONE-I (PHASE-II) Piped Water Supply Scheme, Block: Krishnagar-I,Dist. Nadia Under EMD, PHE Dte.
Sl. No. Item Description
1Part-A
2Supply, Delivery and storage at site of horizontal Split casing Centrifugal Pumping Machineries with baseplate, flexible coupling, coupling guard, foundation bolt etc. having the following specification and as perNIT. :(pumps suitable for PLC operated unmaned operation facility) (For pumping water from CWR to OHR) Discharge :- 95m3 per hour Generated Head :- 40 MWC H-Q-P Curve of pumps in test bed has to be submitted during the delivery.
3Supply, Delivery and Storage at site horizontal foot mounted induction motor suitable for the pump duty mentioned above ( item No- 1) with adequate margin as specified in the NIT. Routine test certificate of Induction Motor has to be submitted during delivery
4Supply, Delivery and storage at site of MonoblockVvacuum Pumping Machinarywith the following specification and as perNIT. : A) Vacuum : upto 600 mm of Hg B) Air Flow Rate : 1.8 to 20.5 m3 / Hr
5Supply, delivery and storage at site Lift Type 150 mm Foot valve combined with stainer as per IS : 4038 PN-0.6 and as per detail given in the NIT . :-N.B. : Test Certificate to be produced for each valve ( AT SUCTION SIDE OF PUMP )
6Supply, delivery and storage at site of CI doble flanged single door swing check125 mm dia N.R.Vas per IS : 5312, Part-I, PN-1.0 and as per detail given in NIT. :-N.B. : Test Certificate to be produced for each valve. (AT DELIVERY SIDE OF PUMP)
7Supply, delivery and storage at site 125 mm diaCast Iron actuator operated wafer type butterfly valvegenerally conforming to IS:13095 and PN-1.0. and as per detail given in NIT. :-N.B. : Test Certificate to be produced for each valve (AT DELIVERY SIDE OF PUMP )
8Supply, delivery and storage at site 125 mm diadouble flanged Cast Iron manually operated non-rising spindle sluice valve generally conforming toIS:14846 PN-1.0.and as per detail given in NIT. :-N.B. : Test Certificate to be produced for each valve.(AT COMMON DELIVERY HEADER )
9Supply, delivery and storage at site 80 mm diaCast Iron kinetic double orifice air released valve as per relevant IS, PN-1.0.and as per detail given in NIT. :-N.B. : Test Certificate to be produced for each valve. (AT COMMON DELIVERY HEADER )
10Supply, Delivery and Storage at site MS Dismantling Joint DN 125mm PN 1.0 ( for Delivery side & common header ofpump )
11Supply, Delivery and Storage at site Bourdon type pressure & compound gauges, 150 mm dia cast Aluminium Dial with ,SS internal, DN 15 GI impulse line with three way cock.
12a) Pressure Guages(0 - 15 kg/cm2)
13b) Compound Guages ( +1 to -1 KSCG)
14Supply, Delivery and Storage at site of 150 mm dia , thickness 5.4mm and 125 mm dia 5.4 mm thick MS Black Pipe conforming to IS:3589 Gr.330 (For Suction, Delivery & Delivery Header) along with necessaryBends,fittings viz. flanges, bolts, nuts, gaskets ,eccentric reducers ,concentric enlarger etc. as reqd. to make the installation complete in all respect andas perNIT.
15Supply delivery and storage at site of Ultrasonic/Radartype continuous level measuring unit with provision of 4 to 20 mA analogue signal, indicator and recorder for continuous level monitoring as well as 5 nos. relay out put for sensing high, low, low - low level in suction sump as per specification given in NIT.
16Supply, Delivery and Storage at site20 mm dia,G.IPipes(medium duty),water storage pvc tank , Bends,sockets, Tees,fittings, and other specials,gaskets , solenoide valve ,gate valve for auto & manual operation etc. as reqd. to make the piping arrangement of vacuum pumpcomplete in all respect as perNIT. (For priming arrangement)
17Supply, Delivery and Storage at Site 2 mm. thick CRCA Sheet Steel Enclosed Cubical type Indoor Floor Mounted415 Volt MCCPanelhaving required Feeders with PLC as per specification given in NIT.
18Supply, Delivery and Storage at Site 2 mm. thick CRCA Sheet Steel Enclosed Cubical type Indoor wall Mounted415 Volt power distribution board (PDB)having required Feedersas per specification given in NIT.
19Supply, Delivery and storage at site 1.1 KV Grade50 mm2 3½core XLPE insulated Cupper armoured Cable as per technical specification of NIT.(From WBSEDCL end Cut out to PDB Panel) )
20Supply, Delivery and storage at site 1.1 KV Grade70 mm2 3½core XLPE insulated Aluminiun armoured Cable as per technical specification of NIT.(For PDB panel to AIRP MCC Panel)
21Supply, Delivery and storage at site 1.1 KV Grade 50 Sq. mm. XLPE insulated Aluminiun armoured Cable as per technical specification of NIT. (For PDB to Low Lift MCC panel . )
22Supply, Delivery and storage at site 1.1 KV Grade 16 Sq. mm.3core XLPE insulated Aluminiun armoured Cable as per technical specification of NIT. (For MCC panel to motor)
23Supply, Delivery and storage at site1.1 KV Grade 2.5 Sq. mm.12core pvc insulated armoured Copper controlCable as per technical specification of NIT. (ForMCC Panel to actuator. )
24Supply, Delivery and storage at site1.1 KV Grade 2.5 Sq. mm.2core pvc insulated armoured Copper controlCable as per technical specification of NIT.(For solenoid valve connection)
25Supply, Delivery and storage at site1.1 KV Grade 4 Sq. mm.2core pvc insulated armoured CopperCable as per technical specification of NIT.(For vacuum pump connection)
26Earthing & lightning protection for Pump house and electrical installation as per ISS and IE rules and as per technical specification of NIT. (Earth pit 2 nos+ 2 L/A)
27Supply, delivery at site and storeage of GI perforated cable tray at Pump house for laying of incoming & outgoing power and control cables to and from MCC Panelhaving proper M.S. structural support as per NIT specification and direction of EIC.
28Supply delivery at site and storage of illumination arrangement like suitable size wire, switch ,switch board ,tube light fitting ,exhaust fan ,ceilling fan , LED outdoor fixturecomplete as per specification of NIT.
29Supply delivery at site and storage of safety equipment like suitable capacity Fire Extinguisher , sand bucket ,fire bracket, rubber mats, shock treatment chart and first aid box,chair ,table,415 volt danger board complete as per specification of NIT.
30Supply and delivery at site and storage of suitable capacity Power Corection arrangement as per specification of NIET
31Supply and delivery at site and storage of suitable capacity Disinfection arrangement with Flow Rate 200 LPH as per specification of NIET
32PART-B
33Installation of all items as mentioned in Sl.No.1 to 28 (Part-A) including construction of Pump foundations, pipe supports, valve supports, laying of cables with necessary jointing materials, earthing arrangement of motors, starters, including supply of all erection items viz. rubber gaskets, nuts & bolts etc., including cost ofwelding etc. as required for complete installation including making slope of floor and arrangement of removing gland leckage wateras per Hydraulic standard & IE rules in compliance with specification of NITand upto entire satisfaction of EIC.
34Painting of the installation (viz.pumps,valves, pipe lines etc.by two coats of epoxy paint (colour to be decided by EIC) over a coat of primer as per NIT specifiaction & direction of EIC.
35Testing & Commissioning of the entire installation i.e.Pumps, Motors,valves etc. as in PART A (Sl no. 1to 28) as per direction and to the entire satisfaction of E.I.C.
36Operation and maintenance of the entire installation in High lift pumping stations on 24 hrs. basis including guarding for a period of 90 days are to be provided with supply of skilled, semi-skilled and un-skilled personnel including watch and ward personnel from the date of commissioning. During maintenance period supply of all consumable materials sundrys and lubricants are to be supplied. Charges of Electrical energy during maintenance period will be borne by the Department.
37Supervision charges for electrical installation by licensed electrician as per IE Rules, 1956 read with latest amendments with overhead expenditures.
38TOTAL OF PART - A
39TOTAL OF PART - B
40TOTAL
41Add: GST @ 18%
42TOTAL
43Add: LW Cess @ 1%