Tender For Provn Of Tower Ac In Bldg No P 290 Provn Of Geyser For Jcos Ors In Bldg No P 391 392 397 Provn Of 20 Geyser For Various Bldg Provn Of Dg Set Of Capacity 62.5 Kva Provn Of Geyser Deep Freezer For Ch Dh In C Zone Provn Of Electric Chim, Shillong-Meghalaya

Military Engineer Services-MES has published Tender For Provn Of Tower Ac In Bldg No P 290 Provn Of Geyser For Jcos Ors In Bldg No P 391 392 397 Provn Of 20 Geyser For Various Bldg Provn Of Dg Set Of Capacity 62.5 Kva Provn Of Geyser Deep Freezer For Ch Dh In C Zone Provn Of Electric Chim. Submission Date for this Tender is 21-08-2023. Diesel Generators Tenders in Shillong Meghalaya. Bidders can get complete Tender details and download the document.




Tender Notice

38960764
Tender For Provn Of Tower Ac In Bldg No P 290 Provn Of Geyser For Jcos Ors In Bldg No P 391 392 397 Provn Of 20 Geyser For Various Bldg Provn Of Dg Set Of Capacity 62.5 Kva Provn Of Geyser Deep Freezer For Ch Dh In C Zone Provn Of Electric Chim
Open Tender
Indian
Meghalaya
Shillong
21-08-2023

Tender Details

Provision Of Tower Ac In Bldg No P 290 Provn Of Geyser For Jcos Ors In Bldg No P 391 392 397 Provn Of 20 Geyser For Various Bldg Provn Of Dg Set Of Capacity 62.5 Kva Provn Of Geyser Deep Freezer For Ch Dh In C Zone Provn Of Electric Chimney In Bldg

Key Value

Document Fees
INR 500 /-
EMD
INR 81560.0 /-
Tender Value
INR 40.78 Lakhs /-

BOQ Items

Name of Work: PROVN OF TOWER AC IN BLDG NO P-290, PROVN OF GEYSER FOR JCO’S & OR’S IN BLDG NO P-391, 392 & 397, PROVN OF 20 GEYSER FOR VARIOUS BLDG, PROVN OF DG SET OF CAPACITY 62.5 KVA, PROVN OF GEYSER & DEEP FREEZER FOR CH & DH IN ‘C’ ZONE, PROVN OF ELECTRIC CHIMNEY IN BLDG NO T-15/17A (COOK HOUSE) AND PROVN OF THREE PHASE POWER SUPPLY NEAR BLDG NO P-561/D AND WALL MOUNTING FANS FOR VARIOUS BLDGS AT RMS
Sl. No. Item Description
1M&L for Point wiring complete with two runs of 1.5 sqmm single core PVC insulated FR-LSH cable1100 volts grade with multi-stranded copper conductors, drawn throughand including PVC double locked Casing & caping including provision of 1.5 sqmm, FR-LSH, PVC insulated copper cable as earth continuity conductor connected to common earth dolly, including PVC rectagular box for mounting switches / sockets / regulators etc. with 3 mm thick plastic laminated sheet cover of suitable size as required at site and 50 mm deep etc complete all as specified and as directed.
2(a) One Exhaust fan pointcontrolled by one, one way switch .
3(b) One 3 pin socket outlet 5 Amps on the Independent board.
4M&L for Switch piano flush type single pole, one way 5Aetc complete all as specified and as directed.
5M&L for ceiling rose 3 terminal PVC/Polycarbonate isolated body complete all as specified and directed.
6M&L point wiring with, two single core, 2.5 Sqmm (nominal area) size multistranded FRLSHcopper conductor cable and one single core 2.5 Sqmm (nominal area) size solid copper conductor cable using colour code as phase , Neutralandas Earth continuity conductor connected to common earth dolly, 1100 volts grade,PVC insulated, unsheathed cabledrawn throughand including PVC casing capping and PVC boards with all fittings and fixing materials for one 5 pin 15 Amps socket outlet point controlled by one way switch etc complete all as specified and as directed.
7M&L Switch socket combination 2 in 1, 5A, flush type complete all as specified and as directed.Make:- Havells/Legrand/Anchor
8M&L Switch socket combination flush type 3 pin 16 Amp etc complete all as specified and as directed.
9Supply and fixing Wall mounted fan 400 mm sweep PP Blade and thermal overload protection for long lasting motor power consumation 58 Watt fan motor speed 1330 RPM Air dilivery 85 (CMM) with accessories complete all as specified and as directed by Engr-in-Charge.
10Supply and fix electric water heater, storage type steel body with copper inner tank and heating element upto 2 KW capacity 25 litre, BEE 5 Star rated complete with all accessories such as safety valve, thermostate, NRV, connection piece etc complete all as specified and as directed.
11Supply and laying tubes Medium grade galvanised GI tubing with all fittings, fixed complete to walls/poles/laid in floors/trenchs/road crossing of size 15 mm dia bore including etc complete all as specified and as directed.
12Supply and laying tubes Medium grade galvanised GI tubing with all fittings, fixed complete to walls/poles/laid in floors/trenchs/road crossing of size 20mm dia bore including etc complete all as specified and as directed.
13S&F Stop valves, cast copper alloy, fancy type, chromium plated screwed down, high pressure, with crutch or butterfly handle, screwed both ends for iron pipe or for unions and fixed etc complete all as specified and as directed.
14S&F15mm boreBib tap fancy type chromium plated with long shank etc complete all as specified and as directed.
15Supply, installation, commissioning of Metal Top Deep Freezer 300/320 Ltrs Capacity single phase 240 volt, 50 Hz complete all as specified as directed. Make LG/Voltas/Blue Star
16Supply and ffixing Voltage stablizer for automatic operation single phase indoor type and designed for input variation between 90-260 volts with digital disply out put voltage stabliser at 230 Volts with energy of± 2.5 % and of capacity 2 KVA etc complete all as specified and as directed.
17M&L for sub main wiring with two runs of4.00 Sq mm and one run of 4.00 Sq mm for earth wire with multi standard copper conductors, 1100 volts grade, drawn throughand including PVC double locked Casing & caping including complete all as specified and as directed. NOTE:- Two runs of 4.00 Sq mm + one run of 4.00 Sq mm and one run of PVC casing & capping and its accessories of suitable size shall be measured as one unit length.
18M&L for MCB Distribution board double door type SPN 4 way, sheet steel, powder painted, with 200 Amp rated copper bus bar neutral link & earth bar etc. and fixing MCBs of various rating capacitycomplete all as specified and as directed.
19M&L for MCB SPN 32 Amps, 230 volts, 50 Hz suitable for fixing in MCB DB "C" seriescomplete all as specified and as directed.
20M&L for MCB SP 6-32 Amps, 230 volts, 50 Hz suitable for fixing in MCB DB "C" seriescomplete all as specified and as directed.
21Supply, installation, testing and commissioning ofcommercial type wall mounted electric chimney made out of IS Certified 16 SWG (304)stainless steel Square pipes and sheets with front turned down, angular frame work fully welded with the following items :- (i) Low height stock pot 24" x 24" x 24" with Stainless Steel Hood (30" x 30" x 22") (ii) Two Burner Indian Cooking Range 48" x 24" x 34" with Stainless Steel Hood 48" x 30" x 22" . Make of burner as approved by GE. (iii) Three Burner Indian Cooking Range 66" x 24" x 34" with Stainless Steel Hood 66" x 30" x 22".Make of burner as approved by GE. (iv) Three Nos 18 Inches Heavy Duty Exhaust Fans of approved Make in MES above Stainless Steel Hood. Make : CG or Equivalent make approved by GE. (v) Civil works such as breaking of existing slabs, plaster and repairing of slabs, matching surfaces with existing one etc. (vi) Transportation
22Excavation in trenches, n exc 1.5 m wide and n exc 1.5 m in depth; for foundation, etc. or for shafts, wells, cesspits, manholes, pier holes, etc. n exc 10 sq m on plan and n exc 1.5 m in depth and getting out in soft/loose soil etc complete all as specified and as directed.
23Returning, filling in, of soil including spreading leveling, watering and well ramming in layers not exceeding 25 cmcomplete all as specified and as directed .
24Removing exvated material to a distance n.exc 50M and deposited/ spreaded where directed at a level n. exc 1.5 M above the starting point completeall as specified and as directed .
25M&L for unreinforced precasted concrete cable cover class HVP type 1 with peak size 300mm x 180mm x 40mmetc complete all as specified and as directed.
26Materials and labour for brick protection cover to underground cables with sub class ‘B’ over burnt brick of size 23 X 11.5 X 7.5 cm, (locally available best quality), laid dry and flat abutting each other with gaps not exceeding 10mm complete all as specified and as directed.
27Materials and labour for sand filling around the cable with approved quality coarse sand for sand cushioning of Under ground cableincludingspreading and punning down to requirred thickness complete all as specified and as directed. (Note: Thickness of sand cushioning after punning down shall be measured for payment purpose)
28Supply and fixing triple pole mechanically operated air break isolator (GOD), vertical mounting, rotating type, mounted on insulator and steel frame with operating mechanism worked from ground level complete in all respect such as gun metal moving contacts and spring loaded gun metal fixed jaws, knife copper jumper strip etc, suitable for 11000 Volts grade, 50 Hz with 9 insulator of rating upto 200 Amps complete all as specified and as directed.
29M&L for lightning arrester non-linear resiser type conforming to IS-3070 (Part-III)-1993 complete, line discharge class-3, nominal discharge current 10 KA (peak), 12 KV rated system voltage peak value high current impulse on 4/10 micro sec, wave shape 65 KA (peak) assy suitable for 11 KV, long duration discharge class-IIwith insulation level not less than 28/75 KV and mounted on hot dip galvanised steel structure incl all clamps, nuts, bolts and washers & connecting to earth complete on pole structure all as specified incl taking down the unserviceable one all as directed.
30Supply and fixing expulsion type drop out fuse unit suitable for 11000 volt and current rating upto 50 to 100 Amps shall be mounted on and including MS channel complete with two post insulator for 11000 volts including necessary clamps, nuts, bolts , washers, the exposed steel surface shall be painted with two coats of synthetic enamel paint over a coat of red oxide primer complete all as specified and as directed.
31M & L for LT cable route indicator of 80 mm dia CI plate duly engravedbolted with 40x6mm flat MS angle iron member of height 0.6 mtr and embeded in PCC 1: 3:6 type C-2 (using 40 mm graded aggregated) of size 20cm x 20cm x 30cm block including necessary earth work etc complete all as specified and as directed.
32Supply and fixing Danger notice plate of 25x20cm size and 1.6mm thick mild steel sheet, vitreous enamelled white, with letters(Local & Hindi language), figures and conventional skull and bones in signal red colour and fixed with M.S. clamps, bolts and nuts of approved size, for HT pole etc complete all as specified and as directed.
33M&L for loose filling with aggregate of gauge 40 to 80 mm of broken stone or boulders, deposited, spread and levelled in layers not exceeding 15cm thick, watered and rammed to a true surface, at transformer yard / two pole / three / four polestructure complete all as specified and as directed.
34Supply, laying connecting and testing XLPE insulated (Earthed) cable in trenches / or fixed on pole etc in screenedPVC bedded galvanised steel strip or wire armoured electric power cable (Heavy duty) with stranded alluminium conductor, 11000 volts grade, cross sectional area 95 Sqmm, 3 core, Confirming to IS-7098 (Part-II) 1985 complete all as specified and as directed. Note : Earth workwill be measured and paid separately under respective item.
35Supply and laying under ground XLPE insulated PVC sheathed (Heavy duty) armoured 1100 volts grade aluminium conductor cable of size 240 Sqmm 3.5 core laid in trenches or fixed to wall / pole / ceiling as per IS 7098 (Part I) including connection cable glands, aluminium lugs etccomplete all as specified and as directed. Note : Earth work, brick protection and sand cushioning and GI Pipe will be measured and paid separately under respective item.
36Cable jointing kit for 11 KV (Earthed) grade cable for outdoor termination heat shrink type joint complete with jointing material and accessories suitable for 3 core XLPE armoured aluminium conductor cable of size 50 sqmm to 95 sqmmcomplete all as specified and as directed.
37Sifting of Transformer from store yard to site, positioning on the platform for installation and commissioning including transportation and labour all as per directed.
38M&L for construction of Platform for transformer of size 2500 x 2500 x 1000 mm with PCC 1:4:8 type D2 foundation and brickwork all around in CM 1:6 including plastering, brick step on one side with whitewashing complete including fixing XPM jali all around (2 Transformer and three pole structure) on angle iron 50 x 50 x 6 mm post and gate openable type with locking arrangment including earth work in any type of soil. Metal work to be painted with two coats of synthetic enamelled paint over a coat of red oxide complete all as specified and directed by Engr-in-charge.
39Materials and labour for earthing complete with galvanised iron earth plate electrode 600 mm x 600 mm x 6 mm thick, burried directly and preferably vertically in ground, earth pit not less than 2.25 Mtr deep below ground level with top edge of the plate not less than 1.5 m below ground level connetced with galvanised strip of 32 x 6mm sizeby means of nuts, bolts, check nuts and washers made of galvanised iron or steel earthing lead to be protected by galvanised iron pipe of 40mm bore (light grade) and other end connected to earthing test point or lightening arrestor or main controlling switch as directed including providing funnel with 20mm bore galvanised iron pipe (medium grade), wire mesh, charcoal or coke and common salt in alternate layer of 15cm (compacted thickness) all round the earth electrode, concrete earth pit in PCC (1:3:6) type C-1 (with 20mm graded aggregate), 50mm thick precast RCC (1:2:4) cover slab (re-inforced with 8mm dia TMT bar @ 15 cm C/C bothways and suitable handle made of 10mm dia) including necessary earth work in excavation, returning filling and removal of surplus earth upto a distance not exceeding 50 m etc all as shown on electrical plate No. 3 of MES Schedule Part-I(2009) complete including testing on completion including taking out unserviceable earthing plate and accessoriesall as specified and as directed. (Note: Earth strip upto a length of 7.50 m from earthplate shall be deemed to be included in quoted rate.)
40Supply and fixing 100 mm bore dia GI pipe, light grade including all fittings laid under road crossings or fixed to polecomplete all as specified and directed.
41Supply, install, testing and commissioning of main LT Panel board, TPN 415 volts, 50 HZ out door kiosk type floor mounted CPRI approved factory made, double door dust, vermin and weather proof IP-65, fabricated out of CRCA sheet not less than 3.15 mm thick with 2mm thick for internal compartment duly powder coated fixed on angle iron pedestal made out suitable size with cable chamber for individual feeders for incomming and outgoing connentions, one set of LED indicator lamp RYB with switch and fuse and the panel board shall be provided with proper ventillation including suitable size of cable alley aluminium bus bar suitable for carrying of current of 600 Amps with suitable connections from MCCB out going to main bus bar to out going MCCBs, colour coded heat shrinkable sleeve and shall be rigidly mounted on suitable size of insulator including necessary PCC foundation of minimum 0.35 m height positioned and fixed with suitable nut, bolts, washers etc to the MC pedestal all as specified and directed comprising of the following:- (a) MCCB 400 Amp 4 Pole 50 Hz 415 Volt with thermal magnetic relaese having rupturing capacity 36 KA-01 Nos (Incoming). (b) MCCB 160 Amps 4 Pole 50 Hz 415 V with thermal magnetic release having rupturing capacity 36 KA-02 Nos (Outgoing). (c) MCCB 100 Amps 4 Pole 50 Hz 415 V with thermal magnetic release having rupturing capacity 36 KA-01 Nos (Outgoing). (d) MCCB 63 Amps 4 Pole 50 Hz 415 V with thermal magnetic release having rupturing capacity 16 KA-02 Nos (Outgoing). (e) Provn of space for MCCB 100 Amps 4 Pole (Spare). (f) 3 Phase digital multi function volt meter and ameter model A, class 1.5 A with relay vega Series-01 Nos. (g) Indicating lamp 240 volts LED type-Set of three.
42Supply and install verticalpack type Tower Air conditioner units indoor/outdoor complete with cordless remote control and with inbuilt air ioniser and Plasma filter for better indoor air quality with twin rotary compresser three phase units 415 volts 50 Hz of capacity 4.0 TR With eco friendly refrigerent. Make:-voltas/blue star/LGakMmm Note :-(i) Cutting holes in walls/ Windowof any thickness for installation of AC etc, connection and making good the disturbed surface to match with the existing surface after work shall be done and rate is included in above rate . (iii) Electrical cable required to connect outdoor unit with indoor unit and indoor unit to voltage stabilizer includedin above rate. (ii)copper piping/ drain piping/ insulation material/ tapping includedin above rate.
43M&L for Triple pole and earth encolsure with a three pin and earth plug with socket complete with one triple pole MCB complete all as specified and as directed.
44S&F MCB triple pole and neutral 415 volts 32 amps, with rupturing capacity 10 KA, "B" curve type, with over load and short circuit protection complete all as specified and as directed.
45S&Fand testing factory made sheet metal enclosurefor MCB DB TPN 4 way 415 volt with double door, IP - 43 protectionduly withfixed in wall/ concealed in wall complete and making good disturbed surfaces of wall, floor etc including electric wire connectionall as directedby Engineer-in-Charge.
46S&F MCB triple pole and neutral 415 volts 63 amps, with rupturing capacity 10 KA, "B" curve type, with over load and short circuit protection complete all as specified and as directed.
47S&F MCB triple pole and neutral 415 volts 40 amps, with rupturing capacity 10 KA, "B" curve type, with over load and short circuit protection complete all as specified and as directed.
48M&L for sub main wiring with Four runs of6.00 Sq mm and one run of 6.00 Sq mm for earth wire with multi standard copper conductors, 1100 volts grade, drawn throughand including PVC double locked Casing & caping including complete all as specified and as directed. NOTE:- Four runs of 6.00 Sq mm + one run of 6.00 Sq mm and one run of PVC casing & capping and its accessories of suitable size shall be measured as one unit length. Make:- Finolex/Havells/RR KabelMake of caping/casing :- Prestoplast/Finolex/supreme
49Supply, Installing, testing and commissioning sound proof acoustic enclosurediesel engine driven generating set, fully wired 415 volts, +/- 1.5%, 3 phase 4 wire 50 HZ, +/- 0.5% 0.80 PF of capacity62.5 KVA, 50KW having continous rating at 1500 RPM(Rated output 114.70KW Prime continious rating), brushless self excited and minimum of 83 BHP capacity engineturbo charged water cooled complete under NTP condition with provision for 10% overload for 1hr on 12hr running and common base plate frame engine standard instrumental panel, self exciting and self regulating control panel with accessories, self starter 12 volts with battery 90 AH , 12 volts -01 Nossystem with battery charging unit SCR typeand battery cable leads , exhaust pipe withcladdingby asbestos rope, sound proof canopy as per CPCB norms II etc. Diesel engine set as per IS 10001 and alternator as per IS -13364 with inbuilt electronic speed governer with micro processor based control panel with floor mounted fuel tank not less than 12 hours running capacity including necessary anti vibration pads including standard control panel as recommended by the manufacturer . (a) (i) Fly wheel to suit coupling (ii) Flexible coupling with guard, bolts and nuts,etc.for exhaust system (iii) Dry type air cleaner filters (iv) Radiator with guard and radiator fan (v) Fuel pump complete with fuel injection systems (vi) Electronic speedgovernor (vii) Fuel filter (viii) Lub oil filter (ix) Self starter 12 Volts DC (x) Exhaust silencer industrial type with pipe 3 m long (xi) Turbo charger (xii) Lub oil pump
50ITEM NO. 47.00 CONTD.. (xiii) Lub oil cooler assembly (xiv) Alternator 12 V for charging of battery (xv) One hand rotary type fuel pump connected with heavy duty pipe upto the tank (xvi) Instrumental panel with the following:- (aa) Self starting key and switch (ab) Lubricating oil pressure guage (ac) Battery charging ammeter (ad) Hour meter and RPM indicator (ae) Lub oil temp guage (af) Water temp guage (xvii) Control panel with MCCBas per OEM- 1 No (xviii) Emergency stop push button outside of the container/ Canopy. (b) Alternator:-It shall be self excited self generated balanced 415 volts, 3 phase, 50 Cycles per second, 62.5 KVAat 0.8 PFor nearest in higher capacity, 1500 RPM, star connected, 4 wire, drip proof enclosure, air cool with radial fan mounted on rotor, screen protected, self ventilated enclosure as per IS 4722/IS 2613 & IEC 34.10 with drip proof enclosure with damper winding on pole faces, static automatic voltage regulator to provide voltage regulation +/-1% and harmonic factor better than 2% from no load to full load from 0.8 to unity power factor, efficiency 92% at 100% load/0.8PF, voltage drop at full load = 20% and insulation of H class and above as per standard practice of OEM (c) Starting batteries 12 V, 90 AH maintenance free with suitable size of cable including fitting and terminals on angle iron frame(self starter sytem with 12 volt DC) - 01 NoMake Exide/ Amaron/Nicco/ Amco. (d) Fuel tank: Made of 1.6 mm thick CRCA sheet and having continous running of 12 hours at full load with level indicator to indicate the oil level of diesel tank, fuel strainer air vent inlet and out let connections with MS pipe of suitable size complete all as specified and as directed. (e) Sheet steel components pre-treated with zinc phosphate prior to polyster powder coating
51ITEM NO. 47.00 CONTD.. (f) Zinc plated or stainless steel fasteners (g) EPDM quality gasket (xix) Provison of light inside the canopy. (xx) Radiator filling access facility from out side (h) Engine and alternator shall be mounted through AVM Pads on common channel iron base frame. (j) Noise level, less than 75db (A) at 1 mtr distance controlled by providing specially designed alternator to controlled the sound at air entry and exit of the enclosure.(The make of Acoustic enclosure shall be OEM of DG Set) (Foundation: Cost of PCC foundation as per manufacturer"s instructions shall be deemed to be included in the Quoted rate) AUTOMATIC MAINS FAILURE (AMF) CONTROL PANEL: factory made cubicle type floor mounted LT panel board, outdoor kiosk type made out of MS angle not less than 25 x 25 x 5mm , and 3.15 thick MS CRCA sheet, fron opening type, protection class IP-65, dust, weatherproof and vermin proof duly powder coated after seven tank process, with elecctrolytic grade copper bus barof 200Amps capacity for three phase and neutral, with all standard switch gear such as power contactors, relays etc. and protection , internal wiring of adequate size PVC insulated multistranded copper conductor cable etc and also consisting of following:-
52ITEM NO. 47.00 CONTD.. (a) MCCB 415 Volts, 125 Amp, rating 4 pole 16 KA rupturing capacity, Microprocessor based release for incoming supply with overload, short circuit and earth fault protection-02 (Incoming from commercial and stand by supply). (b) Ammeter 0-100 Amps, 96x96 mm square dial flush type ISI marked with selectyor switch 3 way-01 set (c) Voltmeter 0-500 volts 96x96 mm square dial flush type ISI marked with rotary selector switch 3 way -01 set. (d) Phase indicator lamps (R-Y-B)- 1 set. (e) Frequency meter digital type 45 to 55 Hz-1 No (f) KWH Meter 3 Phase unbalanced load1200 Amps capacity incl CT coil-1 set (g) All standard relays, circuits and protection required for automatic operation of Gen Set.