Tender For Construction Of Ors Living Accommodation Including Kitchen And Dining Hall At Andrala Bop Of 9 Bn Itbp
Tender Value
2.41 Crore
Estimated cost
Bid Submission
17 Aug 2023
0 days left
EMD
4.83 Lakhs
Bank guarantee accepted
Document Fee
Ref. Documents
Non-refundable
Tender Type
Online
Tender Overview
Organization
Tender ID
Competition Type
NCB
Bidding Type
Tender
Location / State
Leparada → Arunachal Pradesh
EMD Exemption
Not Available
Quantity
Not Available
Website
Contact Person
Address
Project Description
Construction Of Ors Living Accommodation Including Kitchen And Dining Hall At Andrala Bop Of 9 Bn Itbp
BOQ
| Sl. No. | Item Description |
| 1 | Earth work in excavation by manual means in over areas (exceeding 30 cm in depth,1.5 m in width as well as 10 sqm on plan) includinggetting out the excavated soil and disposal of surplus excavated earth, lead upto 50 m and lift upto 1.5 m, as directed by Engineer-in-charge. All kinds of soil |
| 2 | Earth wok in excavation in foundation tranches or drains (not exceeding 1.5m in width or 10 sqm on plan)including dressing of sides and ramming of bottoms lift up to 1.5m ,including getting out the excavated soil and disposal of surplus excavated soil All Kind of soil |
| 3 | Providing and laying in cement concrete ofspecified grade excluding the cost of centring and shuttering .All work upto plinth level 1:5:10 cement concerete (1cement:5 Coarse sand: 8 stone agg. 10 mm size) |
| 4 | Filling available excavated earth ( excluding rock) in trenches, plinth, sides of foundations etc. in layers not exeeding 20 cm in depth, consolicating each deposited layer by ramming and watering, lead up to 50 m an lift up to 1.50 m |
| 5 | Reinforced cement concrete work in walls (any thickness), including attached pilasters, buttresses, plinth and string courses, fillets, columns, pillars, piers, abutments, posts and struts etc. up to floor five level excluding cost of centering, shuttering, finishing and reinforcement :1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size). |
| 6 | Reinforced cement concrete work in beams, suspended floors, roofs having slope up to 15° landings, balconies, shelves, chajjas, lintels, bands, plain window sills, staircases and spiral stair cases up to floor five level excluding the cost of centering, shuttering, finishing and reinforcement with 1:1.5:3 (1 cement : 1.5 coarse sand : 3 graded stone aggregate 20 mm nominal size). |
| 7 | Reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete. Thermo-Mechanically Treated bars. |
| 8 | Centering and shuttering including strutting, propping etc. and removal of form for removal of form for foundations, footings, beams, coloumn etc |
| 9 | Random rubble masonry with hard stone in foundation and plinth including levelling up with cement concrete 1:6:12(1 Cement:6coarse sand:12 graded sone aggregate 20 mm no minal size )at plinth level with :cement mortar 1:6(1 cement:6 coarse sand) |
| 10 | Random rubble masonry with hard stone in super structure and above plinth level and upto flor five level,including levelling up with cement concrete 1:6:12(1 Cement:6coarse sand:12 graded sone aggregate 20 mm no minal size )at window sills, ceiling level and the like with :cement mortar 1:6(1 cement:6 coarse sand) |
| 11 | Providing wood work in frames ofdoors, window, clerestory windows and other frames, wrought, framed and fixe in position, Kiln seasoned and chemically treated Local wood . |
| 12 | Providing wood work in frames of false ceiling portition etc. sawn and put up in position kilnseasoned and chemically treated hollock/ Local wood |
| 13 | Providingand fixing wooden moulded beading to ceiling with iron screws plugs and ppriming coat on unexposed surface etc complete 2 nd class Teak wood 35x10 mm |
| 14 | Providing and fixing panelled or panelled and glazed shutters for doors, windows and clerestory windows including ISI marked M.S. pressed butt hinges bright finished of required size with necessary screws excluding, panelling which will be paid for separately, all complete as per direction of Engineer-in-charge. First class local pine wood . 35 mm thick shutters |
| 15 | Providing and fixing panelling or panelling and glazing in panelled or panelled and glazed shutters for doors, windows and clerestory windows ( Area of opening for panel inserts excluding portion inside grooves or rebates to be measured). Panelling for panelled or panelled and glazed shutters 25 mm to 40 mm thick :First class local pine wood planks, Grade I, Type II IS: 12823 marked |
| 16 | Providing and fixingshutters forwindows using 4 mm thick plain acrylic sheet as glazing including ISI marked M.S. pressed butt hinges bright finished of required size with necessary screws. Available Local Wood |
| 17 | Providing and fixingfly proof galvanised M.S. wire gauge shutters for doors, windows and clerestory windows usingwire gauge withaverage width of apetre 1.4 mm in both directions with necessary screws including black enamelled ISI marked M.S butt hinges with necessary screws. First class local pine wood 35 mm thick |
| 18 | Providing C.G.I.sheet roofing with G.I,. J or L hooks bolt & nuts 8mm Dia with bitumen and G.I. limpet washers including a coatof approved steel primer and two coat of approved paint on over lapping of steel complete excluding the cost of purnils , rafter etc. – 0.63mm thick with zinc coated not less than 120gm/sqm. |
| 19 | Providing ridges or hips of width 60 cm overall width plain G.S. sheet fixed with polymer coated J or L hooks, bolts and nuts 8 mm dia G.I. limpet and bitumen washers complete : 0.63 mm thick zinc coating not less than 275 gm/sqm |
| 20 | Extra for providing and fixing wind ties of 40x 6mm flat iron section |
| 21 | 25 mm thick planking, tounged and grooved in flooring including fixing with iron screws complete with : Kiln seasoned and chemically treated hollock wood |
| 22 | Providing and fixing Pre-laminated flat pressed 3 layer (medium density) particle board or graded wood particle board IS : 3087 marked, with one side decorative and other side balancing lamination Grade I, Type II exterior grade IS : 12823 marked, in shelves with screws and fittings wherever required, edges to be painted with polyurethane primer (fittings to be paid separately). 18 mm thick |
| 23 | Providing and fixing insulation board ceiling of approved quality with necessary nails etc complete (frame work to be paid separately): White face insulating board 12 mm thick |
| 24 | Providing and fixing inside wall lining with 20 mm thick wooden palnking tongued and grooved with necessary fixing arrangement and screws etc. complete : 20 mm thick first class local Pine wood planks |
| 25 | Providing and fixing first class local pine wood 20 mm thick planking, tongued and grooved in false ceiling with necessary nails etc complete ( Frame work to be paid separately) |
| 26 | Providing and fixing glass strips in joints of cement concrete floors 40 mm wide and 4 mm thick |
| 27 | Cement concrete flooring 1:2:4(1cement 2 coarse sand:4 graded stone aggregate) finished with a floating coat of neat cement including cement slurry but excluding the cost of nosing of steps etc.Complete 40 mm thick with 20 mm nominal size stone aggregate |
| 28 | Providing and laying viniyl flooring 0.80 mm thick o approved shade to be fixed with adhesive of approved qly. : 80 mm thick |
| 29 | 20 mm cement plaster of mix : 1:6 (1 cement : 6 coarse sand) |
| 30 | Structural steel work reveted, bolted or welded in built up section, trusses and framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer all complete: |
| 31 | Providing and fixing bolts including nuts and washers complet. |
| 32 | Providing and fixing ISI marked oxidised M.S. sliding door bolts with nuts and screws etc. complete : 250x16 mm |
| 33 | Providing and fixing ISI marked oxidised M.S. tower bolt black finish, (Barrel type) with necessary screws etc. complete :250x10 mm |
| 34 | Providing and fixing ISI marked oxidised M.S. tower bolt black finish, (Barrel type) with necessary screws etc. complete :150x10 mm |
| 35 | Providing and fixing ISI marked oxidised M.S. handles conforming to IS:4992 with necessary screws etc. complete :125 mm |
| 36 | Applying priming coat With ready mixed red oxide zinc chromate primer of approved brand and manufacture on steel galvanised iron/steel works |
| 37 | Applying priming coat wih ready mixed primer of with mixed pink or gray primer of approved brand and manufacTure on wood work |
| 38 | Paintingwith synthetic enamel paint of approved brand and manufacture of required colour to give an even shade : Two or more coats on new work |
| 39 | White washing with lime to give an even shade: New work (three or more coats) |
| 40 | Finishing wall with water proofing cement paint of required shade: New work (Two or more coats @ 3.84 Kg/10 sqm) |
| 41 | Providing and fixing wash basin with C.I. /M.S. brackets, 15 mm C.P. brass pillar taps,Kingston/Gem/Techno/ Parko,32 mm C.P. brass waste of standard pattern,includingpainting of fittings and brackets, cutting and making good the walls wherever require :A]White Vitreous China Wash basin size 630x450 mm with a single 15 mm C.P. brass pillar tap. |
| 42 | Providing and fixing PTMT towel rail complete with brackets fixed to wooden cleats with CP brass screws with concealed fittings arrangement of approved quality and colour. |
| 43 | Providing and fixing G.I. pipes complete with G.I. fittings and clamps, i/c cutting and making good the walls etc. (internal work, exposed on wall) and painting G.I. pipes and fittings with synthetic enamel white paint with two coats over a ready mixed priming coat, both of approved quality. : 15 mm dia nominal bore |
| 44 | Providing and fixing G.I. pipes complete with G.I. fittings including trenching and refilling etc.: 20 mm dia nominal bore |
| 45 | P/F steel pegs batten with 6 nos steel peg |
| 46 | Providing and fixing 15 mm nominal bore, 90 mm long (weighing not less than 93 gms) PTMT bib cock of approved quality and colours. |
| 47 | Providing and fixing 15 mm nominal bore, 86 mm long (weighing not less than 88 gms) PTMT stop cock of approved quality and colours. |
| 48 | Providing and laying in position cement concrete of specified grade excluding the cost of centring and shuttering-All work upto plinth level: 1:2:4 ( 1 Cement: 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) |
| 49 | Wiring for light point/fan point/ exhaust point/ call ball point with 1.5 sq. mm FR PVC insulated copper conducter single core cable in surface/ recessed 20 mm PVC conduit (Polymer/Polyfit/Anchor/ISI), with piano type switch (Anchor/CONA), phenolic laminated sheet, suitable size M.S. box and earthing the point with 1.5 Sqmm FR PVC insulated copper conducter single core cable (Plaza/Havell\"s/Anchor) etc as required.Group A |
| 50 | Wiring for circuit/sub main wiringalong with earth wire with 2x1.5 sq mm + 1x1.5 sq mm earth wire FR PVC insulated copper conducter, single core cable in surface/ recessed 20 mm PVC conduit (Polymer/Polyfit/Anchor/ISI)as required. Wire should be of Plaza/Havell\"s/Anchor) |
| 51 | Wiring for circuit/sub main wiringalong with earth wire with 2x10 sq mm + 1x10 sq mm earth wire FR PVC insulated copper conducter, single core cable in surface/ recessed PVC conduit (Polymer/Polyfit/Anchor/ISI) as required. Wire should be of Plaza/Havell\"s/Anchor) |
| 52 | Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, incuding P/F 6 pin 5/6 amps piano type socket outlet and 15/16 amps piano type switch, connections etc as required |
| 53 | Supplying and fixing PVC angle/Batten holder (Anchor/Ambit) including connectionsetc. as required. |
| 54 | Supplying and fixing MCB DB 6 ways (Havell\"s) complete with connections, testing and commissioning etc as required. |
| 55 | Supplying and fixing double Pole 40 Amp, 240 volts, isolator (Havells) in the existing MCB DB complete with connections, testing and commissioning etc as required. |
| 56 | Supplying and fixing 16 Amp rating, 240/415 volts (Havells), \"C\" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc as required. Single pole |
| 57 | Supplying and fixing 18 watt LED batten fitting (Havell\"s/Philips/Bajaj) complete |
AI Tender Summary
Tender Timeline
Aug 02, 2023
11:30 IST
Tender Published
Tender notice published.
CompletedAug 17, 2023
17:00 IST
Bid Submission Deadline
Online submission via eProcurement portal.
CompletedAug 18, 2023
Bid Opening Date
Technical bids will be opened and evaluated.
CompletedTender Documents
Download All (ZIP) ↓
Disclaimer
We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender