Water Resources and Irrigation Local Bodies Closing in 0 days TDR #38952992

Jal Jeevan Mission (Jjm)-2021-2022Wqm&S Activities In Sub District, District Level And State Level Laboratories. Procurement Ofbiological Safetycabinet In Various Quality Control Laboratories-Jjm-2021-22.Supply And Installation Of Bio Safety Cabinet In Va

Issued by Local Bodies · Ernakulam, Kerala
Tender Value
62.92 Lakhs
Estimated cost
Bid Submission
14 Aug 2023
0 days left
EMD
50000
Bank guarantee accepted
Document Fee
2760
Non-refundable
Tender Type
Online

Tender Overview

Competition Type
NCB
Bidding Type
Tender
Location / State
Ernakulam → Kerala
EMD Exemption
Not Available
Quantity
Not Available

Project Description

Jal Jeevan Mission ( Jjm ) -2021-2022Wqm&S Activities In Sub District, District Level And State Level Laboratories. Procurement Ofbiological Safetycabinet In Various Quality Control Laboratories-Jjm-2021-22.Supply And Installation Of Bio Safety Cabinet In Various Quality Control District Labs.-General Civil Work , Supply And Installation Of Biosafety Cabinet , Od181376 / 2022-2023: Biosafety Cabinet With The Working Area Size Of 4 Feet And Maximum External Dimension Of Wxdxh 1500Mm X 800Mm X 1600Mm And Maximum Internal Dimension Of Wxdxh 1270Mm X 630Mm X 780Mm Should Be Class Ii A2 ( 70% Recirculate, 30% Exhaust ) Should Have Lcd / Led Display Backlit Screen Display , Microprocessor Control For All The Safety Parameters And System Real Time Monitoring With Alarm. Biosafety Cabinet Should Have Average Inflow Velocity 0.51M / S Minimum, Average Downflow Velocity 0.25-0.40M / S. Main Body Should Be Made Of Electro-Galvanized Steel With Powder Coated Finish. Working Chamber Should Be Made Up From Single Piece Of Ss 304 Sheet With Rounded Corner Joints For Easy Cleaning. Should Have World Class Brushless Dc / Dual Dc Blower Motor With Automatted Air Volume Compensation For Stable Air Flow And Reduce Energy Consumption. Should Have Non-Obstructive Air Return Mode In The Front Suction Panel. The Drain Pan Should Be Ss And There Should Be In-Built Drain Valve At The Bottom Of The Working Chamber For Easy Cleaning. Should Havepressure Sensor For Detecting Pressure Drop Of Flow Of Air. Germicidal Uv Light With Timer And Lamp Duration Should Be Provided. Should Have Automatic Function Of Uv On / Off While Closing And Opening The Front Door Should Have Uv Lamp And Led / Fluorescentlamp Should Have Sound Or Flash Alarms For, Filter Blocked, Filter Shattered, Filter Life Time Reminder, Inflow & Down Flow Velocity. Sash Glass Should Be Of Safetyglass With Uv-Proof And 5Mm Thickness Or Better. Sash Window Opening Should Be 250Mm Minimum During Working. Cabinet Should Have Arm Rest For Comfortable Working Posture And Prevents Grille Blocking. Should Have Access Port For Water & Gas And Water Proof Sockets 2 Nos ( Minimum ) Should Have Switches And Sockets For Electrical Loop Sterilizer Cleanliness Requirements: Cleanliness: Hepa: Iso Class 5 Or Better Filtration Efficiency: Hepa:&Ge; 99.995%, @0.3ΜM. Or Better Filtershould Have : Down Flow : Hepa:&Ge; 99.995%, @0.3ΜM Particle Size; Class H14 As Per En1822 Or Better Exhaust : Hepa:&Ge; 99.995%, @0.3ΜM Particle Size;Class H14 As Per En1822 Or Better Maximum Noise Level : 65Db. Should Have Heavy Duty Castors With Adjustable Foot ( 4Nos ) For Convenient Movement. Cabinet Should Be Independently Tested And Certified By Nsf 49 With Listing On Nsf Website. Energy Consumption ( Maximum ) : 400W Power Supply : 230+10V, 50 / 60 Hz Iq / Oq / Pq Documentation Shouldbe Provided For Each Equipment Should Provide Calibration Certificate Traceable To Nabl For Each Equipment. Hard Copy Of Instrument Manual With Specification Details Warranty Three Years Minimum

BOQ

Work Name:Jal Jeevan Mission (JJM)-2021-2022WQM&S activities in sub district, District level and state level laboratories. Procurement ofBiological safetycabinet in various quality control Laboratories-JJM-2021-22.Supply and installation of Bio Safety Cabinet in various quality control District labs.-General Civil Work
Sl. No. Item Description
1Supply and installation of Biosafety cabinet
2OD181376/2022-2023: Biosafety cabinet with the working area Size of 4 feet and maximum external dimension of WXDXH 1500mm x 800mm x 1600mm and maximum internal dimension of WXDXH 1270mm x 630mm x 780mm Should be Class II A2 (70% Recirculate, 30% Exhaust) Should have LCD/ LED display backlit Screen Display , microprocessor control for all the safety parameters and system real time monitoring with alarm. Biosafety cabinet should have Average inflow velocity 0.51m/s minimum, Average downflow velocity 0.25-0.40m/s. Main body should be made of Electro-galvanized steel with powder coated finish. Working Chamber should be made up from single piece of SS 304 sheet with rounded corner joints for easy cleaning. Should have World Class brushless DC /dual DC blower motor with automatted air volume compensation for stable air flow and reduce energy consumption. Should have Non-obstructive air return mode in the front suction panel. The drain pan should be SS and there should be in-built drain valve at the bottom of the working chamber for easy cleaning. Should havePressure sensor for detecting pressure drop of flow of air. Germicidal UV light with timer and lamp duration should be provided. Should have automatic function of UV ON/OFF while closing and opening the front door Should have UV Lamp and LED/FluorescentLamp Should have Sound or Flash Alarms for, Filter Blocked, Filter Shattered, Filter Life Time Reminder, Inflow & Down flow Velocity. Sash glass should be of safetyglass with UV-Proof and 5mm thickness or better.Sash window opening should be 250mm minimum during working.Cabinet should have arm rest for comfortable working posture and prevents Grille blocking. Should have access port for water & gas and water proof Sockets 2 Nos(minimum) Should have switches and sockets for electrical loop sterilizer Cleanliness Requirements:Cleanliness: HEPA: ISO Class 5 or betterFiltration efficiency: HEPA:≥ 99.995%,@0.3μm. or better Filtershould have :Down flow : HEPA:≥ 99.995%,@0.3μm particle size; class H14 as per EN1822 or betterExhaust : HEPA:≥ 99.995%,@0.3μm particle size;class H14 as per EN1822 or better Maximum Noise Level : 65dB. Should have heavy duty castors with adjustable foot (4nos) for convenient movement. Cabinet should be independently tested and Certified by NSF 49 with listing on NSF website. Energy consumption( maximum) : 400w Power supply : 230+10V,50/60 Hz IQ/OQ/PQ documentation shouldbe provided for each equipment Should provide Calibration certificate traceable to NABL for each equipment. Hard copy of instrument manual with specification details Warranty three years minimum

AI Tender Summary

OUR REF NO 38952992
AUTHORITY Local Bodies
TENDER VALUE 62.92 Lakhs
LAST DATE 14-08-2023
Authority
Authority Name Kerala Water Authority
Work Description Jal Jeevan Mission ( Jjm ) -2021-2022Wqm&S Activities In Sub District, District Level And State Level Laboratories. Procurement Ofbiological Safetycabinet In Various Quality Control Laboratories-Jjm-2021-22.Supply And Installation Of Bio Safety Cabinet In Various Quality Control District Labs.-General Civil Work , Supply And Installation Of Biosafety Cabinet , Od181376 / 2022-2023: Biosafety Cabinet With The Working Area Size Of 4 Feet And Maximum External Dimension Of Wxdxh 1500Mm X 800Mm X 1600Mm And Maximum Internal Dimension Of Wxdxh 1270Mm X 630Mm X 780Mm Should Be Class Ii A2 ( 70% Recirculate, 30% Exhaust ) Should Have Lcd / Led Display Backlit Screen Display , Microprocessor Control For All The Safety Parameters And System Real Time Monitoring With Alarm. Biosafety Cabinet Should Have Average Inflow Velocity 0.51M / S Minimum, Average Downflow Velocity 0.25-0.40M / S. Main Body Should Be Made Of Electro-Galvanized Steel With Powder Coated Finish. Working Chamber Should Be Made Up From Single Piece Of Ss 304 Sheet With Rounded Corner Joints For Easy Cleaning. Should Have World Class Brushless Dc / Dual Dc Blower Motor With Automatted Air Volume Compensation For Stable Air Flow And Reduce Energy Consumption. Should Have Non-Obstructive Air Return Mode In The Front Suction Panel. The Drain Pan Should Be Ss And There Should Be In-Built Drain Valve At The Bottom Of The Working Chamber For Easy Cleaning. Should Havepressure Sensor For Detecting Pressure Drop Of Flow Of Air. Germicidal Uv Light With Timer And Lamp Duration Should Be Provided. Should Have Automatic Function Of Uv On / Off While Closing And Opening The Front Door Should Have Uv Lamp And Led / Fluorescentlamp Should Have Sound Or Flash Alarms For, Filter Blocked, Filter Shattered, Filter Life Time Reminder, Inflow & Down Flow Velocity. Sash Glass Should Be Of Safetyglass With Uv-Proof And 5Mm Thickness Or Better. Sash Window Opening Should Be 250Mm Minimum During Working. Cabinet Should Have Arm Rest For Comfortable Working Posture And Prevents Grille Blocking. Should Have Access Port For Water & Gas And Water Proof Sockets 2 Nos ( Minimum ) Should Have Switches And Sockets For Electrical Loop Sterilizer Cleanliness Requirements: Cleanliness: Hepa: Iso Class 5 Or Better Filtration Efficiency: Hepa:&Ge; 99.995%, @0.3ΜM. Or Better Filtershould Have : Down Flow : Hepa:&Ge; 99.995%, @0.3ΜM Particle Size; Class H14 As Per En1822 Or Better Exhaust : Hepa:&Ge; 99.995%, @0.3ΜM Particle Size;Class H14 As Per En1822 Or Better Maximum Noise Level : 65Db. Should Have Heavy Duty Castors With Adjustable Foot ( 4Nos ) For Convenient Movement. Cabinet Should Be Independently Tested And Certified By Nsf 49 With Listing On Nsf Website. Energy Consumption ( Maximum ) : 400W Power Supply : 230+10V, 50 / 60 Hz Iq / Oq / Pq Documentation Shouldbe Provided For Each Equipment Should Provide Calibration Certificate Traceable To Nabl For Each Equipment. Hard Copy Of Instrument Manual With Specification Details Warranty Three Years Minimum
Basic Detail
Tender No 04/ 2022-23 / SRI / NTR
Bidding Type Tender
Location
City Ernakulam
State Kerala
Key Dates
Publish Date 02 Aug 2023
Submission Date 14 Aug 2023
Open Date 16 Aug 2023
Finance
Tender Value 62.92 Lakhs
Tender Fee 2760
EMD 50000
Exemption Not Available
Document List
5472430e-4c06-4d61-98cc-745621d9f18d.html
BOQ_876491.xls
KWAGeneralConditionsforeT.pdf
NITBIOSAFETY.pdf
TechnicalComplianceformat.pdf
Tendernotice_1.pdf

Unlock Full AI Tender Summary

Get instant access to the complete AI-generated analysis — scope, eligibility, timeline & more.

Instant Access Secure Free
Your details are secure and used only for document delivery.

Tender Timeline

Aug 02, 2023
11:30 IST

Tender Published

Tender notice published.

Completed
Aug 14, 2023
17:00 IST

Bid Submission Deadline

Online submission via eProcurement portal.

Completed
Aug 16, 2023

Bid Opening Date

Technical bids will be opened and evaluated.

Completed

Tender Documents

Download All (ZIP) ↓
html

5472430e-4c06-4d61-98cc-745621d9f18d.html

xls

BOQ_876491.xls

pdf

KWAGeneralConditionsforeT.pdf

pdf

NITBIOSAFETY.pdf

pdf

TechnicalComplianceformat.pdf

pdf

Tendernotice_1.pdf

Disclaimer

We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender

TenderDetail
Loading tenders