}

Tender For Development Of Sports Complex At Sector 23 Dwarka.Sub Head : Supply, Installation, Testing And Commissioning Of Dg Set At Sector 23 Dwarka Complex., Delhi-Delhi

Delhi Development Authority-DDA has published Tender For Development Of Sports Complex At Sector 23 Dwarka.Sub Head : Supply, Installation, Testing And Commissioning Of Dg Set At Sector 23 Dwarka Complex.. Submission Date for this Tender is 19-08-2023. Sports Complex Tenders in Delhi Delhi. Bidders can get complete Tender details and download the document.




Tender Notice

38934076
Corrigendum : Tender For Development Of Sports Complex At Sector 23 Dwarka.Sub Head : Supply, Installation, Testing And Commissioning Of Dg Set At Sector 23 Dwarka Complex.
Open Tender
Indian
Delhi
Delhi
19-08-2023

Tender Details

Development Of Sports Complex At Sector 23 Dwarka.Sub Head : Supply, Installation, Testing And Commissioning Of Dg Set At Sector 23 Dwarka Complex. 1 Part-I Sitc Of D.G Setproviding, Installing, Testing & Commissioning Of Silent Type D.G Set As Latest Cpcb Norms Having Prime Power Rating Of 400 Kva, 415 Volts At 1500 Rpm, 0.8 Lagging Power Factorat 415 Voltsuitablefor 50 Hz 3 Phase System & For 0.85 Loadfactoralong Withsuitableratingelectricalmanual Control Panel And Consisting Of The Following:A ) Diesel Enginedieselengine 4Stroke Water Cooled, Electric Start Of Suitable Bhpat1500 Rpmsuitable For Delivering Required Output Of Alternatorat Ntpconditionsandconfirming Tobs 5514, Bs 649, Is 10000, Capable Oftaking10% Over Loadingfor Onehour After12 Hour Of Continuous Operation. The Engine Will Be Fitted Complete With All The Required Accessories Along With Electronic Governer Ao.B ) Engine Mounted Instrument Panel Fitted With And Having Digital Display For Following:I ) Start-Stop Switch With Key.Ii ) Water Temperature Indication.Iii ) Lubrication Oil Pressure Indication.Iv ) Lubrication Oil Temperature Indicationv ) Battery Charging Indication.Vi ) Rpm Indication.Vii ) Over Speed Indication.Viii ) Low Lubrication Oil Trip Indication.Ix ) Engine Hours Indication. X ) Inbuilt Diesel Tank.C ) Alternatorsynchronous Alternator Rated 400 Kva, 415 Voltat 1500 Rpm 3 Phase 50 Hz Ac Supply With 0.8 Lagging Power Factor At 40º C, 50% Rh & At 1000Meter Msl. The Alternator Shall Be Having Spdp Enclosure, Brushless, Continuous Duty, Self-Excited Andself-Regulated Through Avr Conforming To Is 4722 / Iec 60034 Suitable For Tropical Condition And With Class H Insulation.D ) Base Frame Foundationboth The Engine And Alternator Shallbemounted On Suitable Base Frame Made Ofm.S. Channel With Necessary Reinforcement Which Shall Be Installedon Suitablecementconcretefoundationand Vibration Isolation Arrangement As Per Recommendations Of Manufacturer.E ) Fuel Tankdaily Service Fuel Tank Of 600 Ltrs. Capacity Fabricated Out Of 3Mm Thick M.S Sheet Complete Withall Standard Accessories Andfuel Piping Between Fuel Tank And Diesel Engine With M.S Class C Pipes Of Suitable Diameter. Complete With Valves, Level Indicator & Accessories As Required As Per Specifications:F ) Exhaust Systemdry Exhaust System Manifoldwith Residentialexhaust Silencer.G ) Starting System12 V / 24 Vdcstarting SystemcomprisingofstartermotorS Voltage Regulator And Arrangement For Initial Excitation Completewith Suitable Nos. Of Batteries ( 150 Ah Capacity Lead Acid Type ) 2 Nos. As Required As Per Specification.H ) Acoustic And Weather Proof Enclosure With Arrangement For Fresh Air Intake For Cooling Of The Engine And Alternator, Extraction, Discharginghot Air Into The Atmosphereas Per Specifications, For In House Power Generation For Emergency Loads. 2 Supply, Installation, Testing And Commissioning Of Standard Automatic Mains Failure Control Suitable For 400Kva Silent Type D.G Set Complete With Relays, Timers, Set Of Cts For Metering & Protection For Overload, Short Circuit, Restricted Earth Fault, Under Frequency, Control Cabling From Amf Panel To Diesel Engine And Elsewhere If Required, All Complete And Inter Locking The Following:A ) Auto / Manual / Test / Off Selector Switchb ) 2 Nos. Over Voltage Relay, 2 Nos. Reverse Power Relayand 2 Nos. Under Voltage Relayc ) 3 Sets Of Current Transformer 15 P 10 Accuracy For Protection And 15 Va Class-I Formeteringd ) Energy Analyzer Unit To Indicate Current Voltage Frequency Power Factor And Kwhe ) Indication Lamp For Load On Mains And Load On Setf ) Fuse For Instrumentsg ) Automatic Battery Charger With Selector Switch For Trickle, Off And Boost.H ) Main Supply Failure Monitori ) Supply Failure Timerj ) Restoration Timerk ) Control Unit With Three Impulse Automatic Enginestart / Stop And Failure To Start Lockoutl ) Impulse Counter With Locking And Reset Facilitym ) On / Off / Control Circuit Switch With Indicatorn ) Audio / Video Annunciation For ( I ) High Water Temperature ( Ii ) Low Lubricating Oil Pressure ( Iii ) Engine Over Speed ( Iv ) Engine Fails To Start ( V ) Full Load / Maximum Load Warning For Automatic Switching On / Off Of D.G Supply 3 Supplying And Making End Termination With Brass Compression Glands And Aluminiumlugs For Following Size Of Pvc Insulated And Pvc Sheathed / Xlpe Aluminium Conductor Cable Of 1.1 Kv Grade As Required. 4 3.5Cx 300Sqmm. 5 Earthing With Gi Earth Plate 600Mm X 600Mm X 6Mm Thick Including Accessories And Providing Masonry Enclouser With Cover Plate Having Locking Arrangement And Watering Pipe Of 2.7 Meter Long Etc. With Charcoal Or Coke And Salt Complete As Required. 6 Supplying And Laying 25Mm X 5Mm G.I. Strip On Surface Or In Recess For Connection Etc As Required.

Corrigendum Details

Sr No CorrigendumDate Corrignedum CorrigendumType NewSubmissionDate
1 17-Aug-2023 Bid Auto Extn Corrigendum Bid Auto Extn Corrigendum 19-08-2023

Key Value

Document Fees
Refer document
EMD
INR 73680.0 /-
Tender Value
INR 36.83 Lakhs /-

BOQ Items

Name of Work :D/o Sports Complex at Sector 23 Dwarka. Sub Head : Supply, Installation, Testing and Commissioning of DG set at Sector 23 Dwarka Complex.
Sl. No. Item Description
1Part-I SITC of D.G SET Providing, installing, testing & commissioning of silent type D.G set as latest CPCB norms having prime power rating of 400 KVA,415 Volts at 1500 RPM, 0.8 lagging power factorat 415 voltsuitablefor 50 Hz 3 phase system & for 0.85 loadfactoralong withsuitableratingelectricalmanual control panel and consisting of the following: A) DIESEL ENGINE Dieselengine 4stroke water cooled,electric start of suitable BHPat1500 RPMsuitable for delivering required output of alternatorat NTPconditionsandconfirming toBS 5514,BS 649, IS 10000,capable oftaking10% over loadingfor onehour after12 hour of continuous operation. The engine will be fitted complete with all the required accessories along with Electronic Governer AO. B) Engine mounted instrument panel fitted with and having digital display for following: i) Start-Stop switch with key. ii)Water temperature indication. iii) Lubrication oil pressure indication. iv) Lubrication oil temperature indication v)Battery charging indication. vi) RPM indication. vii)Over speed indication.viii) Low lubrication oil trip indication. ix) Engine hours indication. x)Inbuilt Diesel tank. C) ALTERNATOR Synchronous alternator rated 400 KVA, 415 Voltat 1500 RPM 3 phase 50 Hz AC supply with 0.8 lagging power factor at 40º C, 50% RH & at 1000meter MSL. The alternator shall be having SPDP enclosure, brushless, continuous duty, self-excited andself-regulated through AVR conforming to IS 4722/IEC 60034 suitable for tropical condition and with class H insulation. D) BASE FRAME FOUNDATION Both the engine and alternator shallbemounted on suitable base frame made ofM.S. channel with necessary reinforcement which shall be installedon suitablecementconcretefoundationand vibration isolation arrangement as per recommendations of manufacturer. E) FUEL TANK Daily service fuel tank of 600 ltrs. capacity fabricated out of 3mm thick M.S sheet complete withall standard accessories andfuel piping between fuel tank and diesel engine with M.S Class "C" pipes of suitable diameter. Complete with valves, level indicator & accessories as required as per specifications: F) EXHAUST SYSTEM Dry exhaust system manifoldwith Residentialexhaust silencer. G) STARTING SYSTEM 12 V/24 VDCstarting systemcomprisingofstartermotor"s voltage regulator and arrangement for initial excitation completewith suitable Nos. of batteries ( 150 AH capacity lead acid type) 2 Nos. as required as per specification. H) Acoustic and weather proof enclosure with arrangement for fresh air intake for cooling of the engine and alternator, extraction, discharginghot air into the atmosphereas per specifications, for in house power generation for emergency loads.
2Supply, installation, testing and commissioning of Standard automatic mains failure control suitable for 400KVA silent type D.G set complete with relays, timers, set of CTs for metering & protection for overload, short circuit, restricted earth fault, under frequency, control cabling from AMF panel to diesel engine and elsewhere if required, all complete and inter locking the following: a)Auto/manual/Test/Off selector switch b)2 Nos. over voltage relay, 2 Nos. reverse power relayand 2 Nos. under voltage relay c)3 Sets of current transformer 15 P 10 accuracy for protection and 15 VA class-I formetering d)Energy analyzer unit to indicate current voltage frequency power factor and KWH e)Indication lamp for load on mains and load on set f) Fuse for instruments g)Automatic Battery charger with selector switch for trickle, off and boost. h)Main supply failure monitor i) Supply failure timer j) Restoration timer k)Control unit with three impulse automatic enginestart/stop and failure to start lockout l) Impulse counter with locking and reset facility m) ON/Off/control circuit switch with indicator n)Audio/video annunciation for (i) High water temperature (ii) Low lubricating oil pressure (iii) Engine over speed (iv) Engine fails to start (v) Full load/maximum load warning For automatic Switching ON/Off of D.G supply
3Supplying and making end termination with brass compression glands and aluminiumlugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.
43.5CX 300Sqmm.
5Earthing with GI Earth Plate 600mm x 600mm x 6mm thick including accessories and providing masonry enclouser with cover plate having locking arrangement and watering pipe of 2.7 meter long etc. with charcoal or coke and salt complete as required.
6Supplying and laying 25mm x 5mm G.I. strip on surface or in recess for connection etc as required.
Disclaimer :
We takes all possible care for accurate & authentic tender information, however Users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender.
Tell us about your Product / Services,
We will Find Tenders for you

Copyright © 2024 · All Rights Reserved. Terms of Usage | Privacy Policy

For Tender Information Services Visit : TenderDetail