| 1 | Distribution wiring in 1.1 KV grade 2x22/0.3 (1.5 sqmm) single core stranded \"FR\" PVC insulated & unsheathed copper wire (Brand approved by EIC) partly in 20mm size PVC rigid conduit \"FR\" (Precision make) [for ceiling portion only] and in 19mm bore, 3mm thick polythene pipe [for horizontal & vertical run embedded in wall], with 1x22/0.3 (1.5 sqmm) single core stranded \"FR\" PVC insulated & unsheathed copper wire for ECC, to light/fan/call bell points with Modular type switch (Brand approved by EIC) fixed on Modular GI switch board complete with 2 no. suitable size “Ph & N” copper bar with top cover plate making earthing attachment fixed on wall incl. mending good damages to original finish. [only PVC Rigid Conduit on ceiling and remaining portion concealed] |
| 2 | Average run 9 mtr[4(d)/ E-25 ] |
| 3 | Distribution wiring in 1.1 KV grade 22/0.3 (1.5 sqmm) single core stranded \"FR\" PVC insulated & unsheathed copper wire (Brand approved by EIC) in 20mm size PVC rigid conduit \"FR\" (Precision make), with 1.1 KV grade 1 x 22/0.3 (1.5 sqmm) single core stranded \"FR\" PVC insulated & unsheathed copper wire as ECC, to 6A 3 pin Modular type plug socket & switch (Brand approved by EIC) on 4 Module GI switch board with 3/4 Module top cover plate on wall incl. necy. connection making earthing attachment, painting and mending good damages to building works. |
| 4 | On Board [ 3 (a) / E- 24 ] |
| 5 | Supplying and fixing PVC Rigid Conduit \"FR\" [Precision Make] of following sizes on wall, ceiling with saddles and other accessories as required and mending good damages to building works |
| 6 | 20 mm size[ 7(a)/ E- 16 ] |
| 7 | 25 mm size[ 7(b)/ E- 16 ] |
| 8 | Supplying and Drawing 1.1 KV single core stranded \"FR\" PVC insulated & unsheathed single core stranded copper wire(Brand approved by E.I.C) of the following sizes in the 19mm/25mm prelaid polythene pipe/PVC rigid conduit as per GS. |
| 9 | 3 x (1.5 sqmm) [1(b) / E- 9 ] |
| 10 | 2x(4 sqmm)+1x (2.5 sqmm) [1(v) / E- 9 ]For 20 A Industrial Plug Socket Board |
| 11 | 2x (6 sqmm) + 1x (4 sqmm) [1(y) / E- 9 ]For SPNDB |
| 12 | S & F solderless Copper socket by crimping of Copper wires. |
| 13 | 2.5 sq mm [9(i) / F-5] |
| 14 | 4 sq mm[9(ii) / F-5] |
| 15 | 6 sq mm [9(iii) / F-5] |
| 16 | Supplying & Fixing sheet metal inspection box (16 SWG) of the following sizes(in mm ) flushed in wall & 3 mm thick bakellite cover as per GS |
| 17 | 175 x 100 x 65 [11(c)/E-4 ,13(c)/E-5] |
| 18 | Supplying and fixing double door Vertical TPN MCB Distribution board for MCCB incomer with IP-42/43 protection, on angle iron frame on wallas per GS as per direction of EIC. |
| 19 | 6 Way ( Up to 160 A )Make - Siemens /L&T/ABB as approved E.I.C as approved by E.I.C ] [15 / D- 12 ] |
| 20 | Supplying and fixing double door Horizontal TPN MCB Distribution board with IP-42/43 protection, concealed in wall as per GS.(Make - Legrand/Siemens/L&T as approved by E.I.C. ) |
| 21 | 4 Way (Make -Make - Legrand/Siemens/L&T as approved by E.I.C] [ 14 / D- 10 ] . |
| 22 | Supplying and fixing double-door SPN MCB Distribution Board with IP-42/43 protection, concealed in wall as per GS. |
| 23 | 2+6 Way [Siemens /Schneider or equivalent model of Legrand/L&T] as approved by EIC. [ 13 / D- 9 ] |
| 24 | Supplying and fixing 240/415 V MCB Isolator on din rail of existing DBs and necessary connection as per GS [Make-Legrand/ Schneider/Siemens/ Crabtree/ L&T) as per direction of EIC. ] |
| 25 | 40 A DP [ 6 / D- 5 ] |
| 26 | 63 A FP [ 6 / D- 5 ] |
| 27 | Supplying and fixing 240/415 V MCB of Breaking capacity 10kA & C characteristics on din rail of existing DBs and necessary connectionas per GS [Make-Legrand/ Schneider/Siemens/Crabtree/L&T) as per direction of EIC. ] |
| 28 | 6-32 SP[ 7 / D- 6] |
| 29 | 63 A TP[ 7 / D- 6 ] |
| 30 | Supplying and fixing 415 V Four Pole MCCB of Breaking capacity 25kA/35kAin existing Vertical DBs including necessary connection as per GS[ Make - Legrand /L&T/Siemens as per direction of EIC.]. |
| 31 | 160 A[10/D- 8 ] |
| 32 | Supply of4/3.5 Core XLPEInsulated & Sheathed Armoured Aluminium Conductor cables for Working Voltage up to 1100 Volts of following sizes [ Make Nicco / Gloster/KEI/Polycab/Havells as approved E.I.C] [NS] |
| 33 | 4 Core 10 Sq. mm |
| 34 | 4 Core 50 Sq. mm |
| 35 | Laying of cableafter cutting floor/pavement/wall as per GS for the following Sizes. |
| 36 | 2.5 to 35 Sq. mm [ 5(i)/ F- 3 ] |
| 37 | Laying of cable upto 2 core 25 sqmm on wall/surface incl. S & F MS saddles with earthing attachment in 10 SWG GI (Hot Dip) Wire, making holes etc. as necy. mending good damages and painting[ 2(a)/ F- 1 ] |
| 38 | Laying of cable from 3/3½ core 35 sqmm to 50 sqmm on wall/surface incl. S & F MS saddles with earthing attachment in 2x 10 SWG GI (Hot Dip) Wire, making holes etc. as necy., mending good damages and painting[ 2(C)/ F- 1 ] |
| 39 | Supplying and fixing compression type gland complete with brass gland, brass ring & rubber ring for dust & moisture-proof entry of XLPE/PVC armoured cables as below : |
| 40 | 4Core 10 Sq. mm [7(c)/F4 ] |
| 41 | 4Core 50 Sq. mm [7(c)/F4 ] |
| 42 | Finishing of the XLPE/PVC insulated armoured cable ends by soldering with cable sockets and insulated tapes etc., including supplying sockets, soldering materials, tapes etc. and making connection to switch, BDB and BBC etc. |
| 43 | 4Core 10 Sq. mm[ 8(xi) /F5] |
| 44 | 4Core 50 Sq. mm[ 8(xvi) /F5] |
| 45 | Supply and delivery of single/twin Industrial LED Batten luminaries incl. Supply of 1 no./2nos. 18W LED Tube [NS] |
| 46 | Twin fittings highly robust industrial box type luminaire [Philips or equivalent make CG / Bajaj / Wipro] incl. 2 no. 18W Master LED Tube |
| 47 | Fixing only single/twin fluorescent light fitting suspended 25 cm bellow the ceiling with 2 No. 20 mm dia EI conduit (14 SWG) supports fixed with “L” type MS clamp whose one side fixed on ceiling with sutable size 4 nos. fastener and other side connected with the conduit with suitable size of bolts and nuts incl. S&F EI conduit, “L” type (125mmx125mm) 6mm thick and 25mm with MS clamps and connecting the length of PVC insulated wire and mending good damages to original finish and painting etc. by 2x24/0.20 mm (1.5sqmm.) flexible copper wire of 1.10 mt. length. [ 17/C-2 ] |
| 48 | Fixing only single/twin LED Batten light fitting complete with all accessories Directly on wall/ceiling as per GS.[ 14d/C-2 ] |
| 49 | Extra for suspension exceeding 25 cm with S&F additional 2 no. 20 mm dia EI conduit (14 SWG) supports & necy. PVC insulated wire and painting etc. as required by 2x24/0.20 mm (1.5sqmm.)flexible copper wire of 1.10 mt. length. [16/C-2] |
| 50 | Supply ofceiling fans with burst-proof P2/S3 Capacitorcomplete with all accessories without regulator.[ Make - Usha striker/ Havells/CG/Orient as approved by E.I.C][NS] |
| 51 | a.1200 mmSweep |
| 52 | Fixing only ceiling fan complete with blades, canopy, fork, rubber bush etc as per GS [ 21 (a) / C-3 ] |
| 53 | Supplying & Fixing MS fan clamp of two piece type for RCCas per approved specification as per GS. [ 29/D-14 ] |
| 54 | Supply & Fixing240V, Modular Socket (2 Module) type fan regulator (Step type)([Legrand-Model Arteror/Myrius or equivalent model of Crabtree/Equivalent make as per direction of E.I.)on existing Modular GI switch board with top cover plate incl. making necy. connections etc. [10/E18] [For Celling Fan] |
| 55 | Supplying & Fixing Industrial Plug & Socket board with 240 V, 20A, SPN & Earth Metal Industrial Plug socket & 20A Industrial top incl. S&F 20 A SP MCB breaking capcity 10kA (C- Curve) in SS enclosure fixed on wall and cecessary conection. [ 17/D-12 ] |
| 56 | Supplying & Fixing Industrial Plug & Socket board with 415 V, 30A, TPN & Earth Metal Industrial Plug socket & 30A Industrial top incl. S&F 32 A TPN/FP MCB breaking capcity 10kA (C- Curve) in SS enclosure fixed on wall and cecessary conection. [ 18/D-12 ] |
| 57 | Earthing with 50 mm dia GI pipe 3.64 mm thick x 3.04 Mts. long and 1 x 4 SWG GI (Hot Dip) wire (4 Mts. long), 13 mm dia x 80 mm long GI bolts, double nuts, double washers incl. S & F 15 mm dia GI pipe protection (1 Mts. long) to be filled with bitumen partly under the ground level and partly above ground level driven to an average depth of 3.65 Mts. below the ground level[By TATA-Medium GI pipe] [2(a)/G-1]. |
| 58 | Excavation of soil for installation of Earth Electrode and filling & ramming. (For Soft Soil) [1(a)/G-1] |
| 59 | Extra for providing masonery enclosure on the top of the earth electrode of overall size 86.36 cm x 86.36 cm x 46 cm deep (below ground level) complete with cemented brick work(1:6) of 25 cm width duly plastered with cement mortar (inside) Cl hinged inspection cover of size 36.56 cm x 35.56 cm with locking arrangement, GI reducer including drilling of 46 nos. 12 mm dia holes on the GI pipe. [3(a)/G-2] |
| 60 | Connecting the equipments to earth busbar including S & F Solid GI (Hot Dip) wire of size as below as per GS |
| 61 | No.-4 SWG [5(a)(i)/G-2] |
| 62 | No.-10 SWG [5(a)(iv)/G-2] |
| 63 | Supplying & fixing earth busbar of galvanized (Hot Dip) MS flat 25 mm x 6 mm on wall having clearance of 6 mm from wall including providing drilled holes on the busbar complete with GI bolts,nuts, washers, spacing insulators etc. as required[4(a)/G-2] |
| 64 | Add GST @18%Rs. |
| 65 | Add LWC @1% except iteam no 13,19 and 23- : Rs |