Tender For Pre-Bid Tie Up For 400Kv And 220Kv Gis- Ss20t, Kinnaur-Himachal Pradesh

Bharat Heavy Electricals Limited-BHEL has published Tender For Pre-Bid Tie Up For 400Kv And 220Kv Gis- Ss20t. Submission Date for this Tender is 08-09-2023. Mechanical Couplings Tenders in Kinnaur Himachal Pradesh. Bidders can get complete Tender details and download the document.




Tender Notice

38911507
Corrigendum : Tender For Pre-Bid Tie Up For 400Kv And 220Kv Gis- Ss20t
Open Tender
Indian
Himachal Pradesh
Kinnaur
08-09-2023

Tender Details

Pre-Bid Tie Up For 400Kv And 220Kv Gis- Ss20t Supply And Services Of 400Kv And 220Kv Gis And Associated Equipments For Powergrid 400Kv New Substation Package Ss20t Project , 420Kv, 6000 A, 63 Ka, Sf6 Gis Bus Barmodule As Per Section-Project, Technical Specification , 420Kv, 4000A, 63Ka Sf6 To Air Bushing , 420Kv, 4000A, 63Ka, Single Phase Sf6 Gasinsulated Bus Duct ( Gib ) Outside Gishall Alongwith Associated Supportstructure , 420 Kv, 4000 A, 63 Ka, Sf6 Gis Linefeeder Bay Module ( With Pir ) As Persection-Project, Technicalspecification , 420 Kv, 4000 A, 63 Ka, Sf6 Gis Linefeeder Bay Module ( Without Pir ) As Per Section-Project, Technicalspecification , 420Kv, 4000 A, 63 Ka, Sf6 Gis Tie Baymodule ( Without Pir ) As Per Section-Project, Technicalspecification , 420Kv, 4000 A, 63 Ka, Sf6 Gis Tie Baymodule ( With Pir ) As Persection-Project, Technicalspecification , 420Kv, 4000 A, 63 Ka, Sf6 Gis Ict Feederbay Module As Per Section-Project, Technical Specification , 420Kv, 4000 A, 63 Ka, Sf6 Gis Bus Reactor Bay Module As Per Section-Project, Technicalspecification , 420Kv, 4000 A, 63 Ka, Sf6 Gis Auxiliarybus Module For Spare Transformer As Persection-Project, Technicalspecification , 420Kv, 4000 A, 63 Ka, Sf6 Gis Auxiliarybus Module For Spare Bus Reactor As Persection-Project, Technicalspecification , Portable Partial Discharge Measurement Test Kitwith All Necessary Accessories, Industrial Grade Laptop And Licensedsoftware As Per Technicalspecification. , Sf6 Gas Leakage Detector , Sf6 Gas Analyzer , Sf6 Gas Processing Unit For 400Kv Gis Station , 245Kv, 1600 A, 50 Ka, Sf6 Gis Ict Feederbay Module As Per Section-Project, Technical Specification , 245Kv, 1600A, 50Ka, 3 Single Phase / 3Phase, Sf6 Gas Insulated Bus Duct ( Gib ) Outside Gis Hall Alongwith Associatedsupport Structure ( Quantity Mentionedhere Is For 3 Phase Type ) , 245Kv, 1600A, 50Ka Single Phase Sf6 To Air Bushing , 245Kv, 1600 A, 50 Ka, Sf6 Gis Auxiliary Bus Module For Spare Transformeras Per Section-Project, Technical Specification , Controlled Switching Device For 420 Kv, 3 Phase Circuit Breaker , 245 Kv, 3000A, 50Ka, Sf6 Gis Bus Barmodule As Per Section-Project, Technical Specification , 245Kv, 3000 A, 50 Ka, Sf6 Gis Buscoupler Bay Module As Persection-Project, Technicalspecification , 400Kv Gis-Sf6 Gas Pressure Relief Device Assembly Of Each Type , Sf6pressuregaugecumswitch / Density Monitorsandpressureswitch As Applicable, Of Each Type-400Kv Gis , Couplingdeviceforpressuregaugecumswitchforconnectinggas Handling Plant Of Each Type-400Kv Gis , Rubbergaskets, ‚¬Å’Oã‚‚¬ÂRingsandsealsforsf6gasforgisenclosure Of Each Type-400Kv Gis , 400Kv Gis-Molecular Filter For Sf6 Gas With Filter Bags ( 5 % Of Totalweight ) , Control Valves For Sf6 Gas Of Each Type-400Kv Gis , 400Kv Gis-Sf6 Gas ( 5 % Of Total Gas Quantity ) , Locking Device To Keep The Dis-Connectors ( Isolators ) And Earthing / Fast Earthing Switches In Close Or Open Position In Caseof Removal Of The Driving Mechanism-400Kv Gis , Uhf Pd Sensors Of Each Type Along With Bnc Connector For 420Kv Gis , 400Kv Gis-Support Insulators ( Gas Through ) Of Each Type ( Complete Withmetal Ring Etc. ) Along With Associated Contacts And Shields , 400Kv Gis-Gas Barriers Of Each Type ( Complete With Metal Ring Etc. ) Along With Associated Contacts And Shields , 400Kv Gis- 4000A Sf6 To Air Bushing Complete In All Respect , Lcc Spares- Aux. Relays, Contactors, Push Buttons, Switches, Lamps, Annunciation Windows, Mcb, Fuses, Timers, Terminal Blocks Etc. Of Eachtype & Rating-400Kv Gis , 400Kv Gis-One Pole Of 4000A Circuit Breaker Without Pir Withinterrupter, Main Circuit, Enclosure And Operating Mechanism Completein All Respect , 400Kv Gis-One Pole Of 4000A Circuit Breaker With Pir With Interrupter, Main Circuit, Enclosure And Operating Mechanism Complete In Allrespect , Trip Coil Assembly With Resistor For420kv Gis Circuit Breaker ( Asapplicable ) , Closing Coil Assembly With Resistor For420kv Gis Circuit Breaker ( Asapplicable ) , Relays, Power Contactors, Push Buttons, Timers & Mcbs Etc. ( Asapplicable ) Of Each Type For 400Kv Gis Circuit Breaker , Auxiliary Switch Assembly Of Each Type For 420Kv Gis Circuit Breaker , 400Kv Gis Circuit Breaker-Operation Counter , 400Kv Gis Circuit Breaker-Hydraulic Operating Mechanism With Drivemotor ( For Hydraulic Operated Mechanism, If Applicable ) , Hydraulic Filter Of Each Type ( For Hydraulic Operated Mechanism, Ifpplicable ) -400Kv Gis Circuit Brekaer , 400Kv Gis Circuit Breaker- Hose Pipe Of Each Type ( As Applicable ) ( Forhydraulic Operated Mechanism, If Applicable ) , 400Kv Gis Circuit Breaker - N2 Accumulator ( For Hydraulic Operatedmechanism, If Applicable ) , Valves Of Each Type ( For Hydraulic Operated Mechanism, Ifapplicable ) -400Kv Gis Circuit Brekaer , Pipe Length ( Copper & Steel ) Of Each Size & Type ( For Hydraulicoperated Mechanism, If Applicable ) -400Kv Gis Circuit Brekaer , Pressure Switches Of Each Type ( For Hydraulic Operated Mechanism, Ifapplicable ) -400Kv Gis Circuit Brekaer , Pressure Gauge With Coupling Device Of Each Type ( For Hydraulicoperated Mechanism, If Applicable ) -400Kv Gis Circuit Brekaer , 400Kv Gis Circuit Breaker-Hydraulic Oil ( 5% Of Total Oil Quantity ) ( For Hydraulic Operated Mechanism, If Applicable ) , Pressure Relief Device Of Each Type ( For Hydraulic Operated Mechanism, If Applicable ) -400Kv Gis Circuit Brekaer , 400Kv Gis Circuit Breaker-Complete Spring Operating Mechanismincluding Charging Mechanism Etc. ( For Spring Operated Mechanism, Ifapplicable ) , 400Kv Gis Circuit Breaker- Complete Hydraulic-Spring Operatingmechanism Including Charging Mechanism Etc. ( For Hydraulic-Springoperated Mechanism, If Applicable ) , Pressure Switches Of Each Type For420kv Giscircuit Breaker ( Forhydraulic-Spring Operated Mechanism, Ifapplicable ) , Pressure Gauge With Coupling Device Of Each Type ( For Hydraulic-Springoperated Mechanism, If Applicable ) -400Kv Gis Circuit Brekaer , 400Kv Gis- Single Phase Of 4000A Disconnector Switch Including Maincircuit, Enclosure, Driving Mechanism And Support Insulator Etc., Complete In All Respect , 400Kv Gis- Single Phase Maintenance Earthing Switch Including Maincircuit, Enclosure, Driving Mechanism And Support Insulator Etc., Complete In All Respect , 400Kv Gis - Single Phase Fast Earthing Switch Including Main Circuit, Enclosure, Driving Mechanism And Support Insulator Etc., Complete Inall Respect , Open / Close Contactor Assembly, Timers, Key Interlock, Interlockingcoils, Relays, Push Buttons, Indicating Lamps, Power Contactors, Resistors, Fuses, Mcbs & Drive Control Cards Etc. ( As Applicable ) Oneof Each Type For One Complete Mom Box For 400Kv Gis Disconnectorswitch , Open / Close Contactor Assembly, Timers, Key Interlock, Interlockingcoils, Relays, Push Buttons, Indicating Lamps, Power Contactors, Resistors, Fuses, Mcbs & Drive Control Cards Etc. ( As Applicable ) Oneof Each Type For One Complete Mom Box For 400Kv Gis Maintenance Earthswitch , Open / Close Contactor Assembly, Timers, Key Interlock, Interlockingcoils, Relays, Push Buttons, Indicating Lamps, Power Contactors, Resistors, Fuses, Mcbs & Drive Control Cards Etc. ( As Applicable ) Oneof Each Type For One Complete Mom Box For 400Kv Gis Fast Earthingswitch , Limit Switches And Aux. Switches For One Complete Mom Box Fordisconnector-400Kv Gis , Limit Switches And Aux. Switches For One Complete Mom Box Formaintenance Earthing Switch-400Kv Gis , Limit Switches And Aux. Switches For One Complete Mom Box For Fastearthing Switch ( If Applicable ) -400Kv Gis , Drive Mechanism For 400Kv Gis Disconnector Switch , Drive Mechanism For 400Kv Gis Maintenance Earth Switch , Drive Mechanism For 400Kv Gis Fast Earthing Switch , Motor For Drive Mechanism For 400Kv Gis Disconnector Switch , Motor For Drive Mechanism For 400Kvgis Maintenance Earth Switch , Motor For Drive Mechanism For 400Kv Gis Fast Earthing Switch , 400Kv Gis- Single Phase Of Current Transformer ( 3 Cores, Type-Cta ) With Associated Enclosure And Primary Conductor Complete In Allrespect , 400Kv Gis- Single Phase Of Current Transformer ( 2 Cores, Type-Ctb ) With Associated Enclosure And Primary Conductor Complete In Allrespect , 400Kv Gis- Single Phase Vt With Associated Enclosure Complete In Allrespect , 220Kv Gis- Cable Connection Enclosure With Main Circuit , 220Kv Gis-Sf6 Gas Pressure Relief Device Assembly Of Each Type , Sf6pressuregaugecumswitch / Density Monitorsandpressureswitch As Applicable, Of Each Type-220Kv Gis , Couplingdeviceforpressuregaugecumswitchforconnectinggas Handling Plant Of Each Type-220Kv Gis , Rubbergaskets, ‚¬Å’Oã‚‚¬ÂRingsandsealsforsf6gasforgisenclosure Of Each Type-220Kv Gis , 220Kv Gis-Molecular Filter For Sf6 Gas With Filter Bags ( 5 % Of Totalweight ) , Control Valves For Sf6 Gas Of Each Type-220Kv Gis , 220Kv Gis-Sf6 Gas ( 5 % Of Total Gas Quantity ) , Locking Device To Keep The Dis-Connectors ( Isolators ) And Earthing / Fast Earthing Switches ( As Applicable ) In Close Or Openposition In Case Of Removal Of The Driving Mechanism-220Kv Gis , Uhf Pd Sensors Of Each Type Along With Bnc Connector For 245Kv Gis , 220Kv Gis-Support Insulators ( Gas Through ) Of Each Type ( Complete Withmetal Ring Etc. ) Along With Associated Contacts And Shields , 220Kv Gis-Gas Barriers Of Each Type ( Complete With Metal Ring Etc. ) Along With Associated Contacts And Shields , 220Kv Gis- 1600A Sf6 To Air Bushing Complete In All Respect , Lcc Spares- Aux. Relays, Contactors, Push Buttons, Switches, Lamps, Annunciation Windows, Mcb, Fuses, Timers, Terminal Blocks Etc. Of Eachtype & Rating-220Kv Gis , 220Kv Gis-One Pole Of 1600A Circuit Breaker With Interrupter, Maincircuit, Enclosure And Operating Mechanism Complete In All Respect , 220Kv Gis-One Pole Of 2500A Circuit Breaker With Interrupter, Maincircuit, Enclosure And Operating Mechanism Complete In All Respect , 220Kv Gis-One Pole Of 3000A Circuit Breaker With Interrupter, Maincircuit, Enclosure And Operating Mechanism Complete In All Respect , Trip Coil Assembly With Resistor For245kv Gis Circuit Breaker ( Asapplicable ) , Closing Coil Assembly With Resistor For245kv Gis Circuit Breaker ( Asapplicable ) , Relays, Power Contactors, Push Buttons, Timers & Mcbs Etc. ( Asapplicable ) Of Each Type For 220Kv Gis Circuit Breaker , Auxiliary Switch Assembly Of Each Type For 245Kv Gis Circuit Breaker , 220Kv Gis Circuit Breaker-Operation Counter , 220Kv Gis Circuit Breaker-Hydraulic Operating Mechanism With Drivemotor ( For Hydraulic Operated Mechanism, If Applicable ) , Hydraulic Filter Of Each Type ( For Hydraulic Operated Mechanism, Ifpplicable ) -220Kv Gis Circuit Brekaer , 220Kv Gis Circuit Breaker- Hose Pipe Of Each Type ( As Applicable ) ( Forhydraulic Operated Mechanism, If Applicable ) , 220Kv Gis Circuit Breaker - N2 Accumulator ( For Hydraulic Operatedmechanism, If Applicable ) , Valves Of Each Type ( For Hydraulic Operated Mechanism, Ifapplicable ) -220Kv Gis Circuit Brekaer , Pipe Length ( Copper & Steel ) Of Each Size & Type ( For Hydraulicoperated Mechanism, If Applicable ) -220Kv Gis Circuit Brekaer , Pressure Switches Of Each Type ( For Hydraulic Operated Mechanism, Ifapplicable ) -220Kv Gis Circuit Brekaer , Pressure Gauge With Coupling Device Of Each Type ( For Hydraulicoperated Mechanism, If Applicable ) -220Kv Gis Circuit Brekaer , 220Kv Gis Circuit Breaker-Hydraulic Oil ( 5% Of Total Oil Quantity ) ( For Hydraulic Operated Mechanism, If Applicable ) , Pressure Relief Device Of Each Type ( For Hydraulic Operated Mechanism, If Applicable ) -220Kv Gis Circuit Brekaer , 220Kv Gis Circuit Breaker-Complete Spring Operating Mechanismincluding Charging Mechanism Etc. ( For Spring Operated Mechanism, Ifapplicable ) , 220Kv Gis Circuit Breaker- Complete Hydraulic-Spring Operatingmechanism Including Charging Mechanism Etc. ( For Hydraulic-Springoperated Mechanism, If Applicable ) , Pressure Switches Of Each Type ( For Hydraulic-Spring Operatedmechanism, If Applicable ) -220Kv Gis Circuit Breaker , Pressure Gauge With Coupling Device Of Each Type ( For Hydraulic-Springoperated Mechanism, If Applicable ) -220Kv Gis Circuit Brekaer , 220Kv Gis- Three Phase Of 1600Adisconnector Switch Including Maincircuit, Enclosure, Driving Mechanismand Support Insulator Etc., Complete Inall Respect , 220Kv Gis- Three Phase Of 2500Adisconnector Switch Including Maincircuit, Enclosure, Driving Mechanismand Support Insulator Etc., Complete Inall Respect , 220Kv Gis- Three Phase Of 3000Adisconnector Switch Including Maincircuit, Enclosure, Driving Mechanismand Support Insulator Etc., Complete Inall Respect , 220Kv Gis- Three Phase Maintenance Earthing Switch Including Maincircuit, Enclosure, Driving Mechanism And Support Insulator Etc., Complete In All Respect , 220Kv Gis - Three Phase Fast Earthing Switch Including Main Circuit, Enclosure, Driving Mechanism And Support Insulator Etc., Complete Inall Respect , Open / Close Contactor Assembly, Timers, Key Interlock, Interlockingcoils, Relays, Push Buttons, Indicating Lamps, Power Contactors, Resistors, Fuses, Mcbs & Drive Control Cards Etc. ( As Applicable ) Oneof Each Type For One Complete Mom Box For 220Kv Gis Disconnectorswitch , Open / Close Contactor Assembly, Timers, Key Interlock, Interlockingcoils, Relays, Push Buttons, Indicating Lamps, Power Contactors, Resistors, Fuses, Mcbs & Drive Control Cards Etc. ( As Applicable ) Oneof Each Type For One Complete Mom Box For 220Kv Gis Maintenance Earthswitch , Open / Close Contactor Assembly, Timers, Key Interlock, Interlockingcoils, Relays, Push Buttons, Indicating Lamps, Power Contactors, Resistors, Fuses, Mcbs & Drive Control Cards Etc. ( As Applicable ) Oneof Each Type For One Complete Mom Box For 220Kv Gis Fast Earthingswitch , Limit Switches And Aux. Switches For One Complete Mom Box Fordisconnector-220Kv Gis , Limit Switches And Aux. Switches For One Complete Mom Box Formaintenance Earthing Switch-220Kv Gis , Limit Switches And Aux. Switches For One Complete Mom Box For Fastearthing Switch ( If Applicable ) -220Kv Gis , Drive Mechanism For 220Kv Gis Disconnector Switch , Drive Mechanism For 220Kv Gis Maintenance Earth Switch , Drive Mechanism For 220Kv Gis Fast Earthing Switch , Motor For Drive Mechanism For 220Kv Gis Disconnector Switch , Motor For Drive Mechanism For 220Kvgis Maintenance Earth Switch , Motor For Drive Mechanism For 220Kv Gis Fast Earthing Switch , 220Kv Gis- Single Phase Of Current Transformer ( 4 Cores ) Withassociated Enclosure And Primary Conductor Complete In All Respect , 220Kv Gis- Single Phase Vt With Associated Enclosure Complete In Allrespect , 220Kv Gis- Single Phase Gas Insulated Surge Arrester With Associatedenclosure And Insulator Complete In All Respect , 220Kv Gis- Surge Counter / Monitor , Services- Gis : 400Kv, Supervision Of Erection Of Gis , Services- Gis : 400Kv, Supervision Of Erection Of Gas Insulated Bus Duct , Services- Gis : 400Kv, Supervision Of Erection Of Sf6 To Air Bushing , Services- Gis : 400Kv, Testing & Commissioning Of Gis , Services- Gis : 400Kv, Final Successful Hv / Power Frequency Testing Of Gis Including Arranging Of Hv Test Kit Along With Operator , Services- Gis : Insulation Co-Ordination Studies For Gis System , Services- Gis : 220Kv, Supervision Of Erection Of Gis , Services- Gis : 220Kv, Supervision Of Erection Of Gas Insulated Bus Duct , Services- Gis : 220Kv, Supervision Of Erection Of Sf6 To Air Bushing , Services- Gis : 220Kv, Testing & Commissioning Of Gis , Services- Gis : 220Kv, Final Successful Hv / Power Frequency Testing Of Gis Including Arranging Of Hv Test Kit Along With Operator , Spares- Gis : 400Kv, Single Phase Bus Bar , Spares- Gis : 400Kv, Gis Metallic Enclosure , Spares- Gis : 400Kv, Expansion Bellows / Joints , Spares- Gis : 400Kv, Tee Bend , Spares- Gis : 400Kv, Angle Bend ( 135° ) , Spares- Gis : 400Kv, L-Bend , Spares- Gis : 220Kv, Single Phase Bus Bar , Spares- Gis : 220Kv, Gis Metallic Enclosure , Spares- Gis : 220Kv, Expansion Bellows / Joints , Spares- Gis : 220Kv, Tee Bend , Spares- Gis : 220Kv, Angle Bend ( 135° ) , Spares- Gis : 220Kv, L-Bend , Services- Gis : Ref. Unit Price Of Gis Individual Item / Equipment - Services For Supervision Of Erection Of Gis , Services- Gis : Ref. Unit Price Of Gis Individual Item / Equipment - Services For Testing & Commissioning Of Gis , Services- Gis : 400Kv, Ref. Unit Price Of Gis Individual Item / Equipment - Hiring Charges Of Hv Test Kit With Operator , Services- Gis : 220Kv, Ref. Unit Price Of Gis Individual Item / Equipment - Hiring Charges Of Hv Test Kit With Operator , 420Kv, 6300A, 63Ka Gis Busbar Module Extension , 420Kv, 4000A, 63Ka, Single Phase Sf6 Gasinsulated Bus Duct ( Gib ) Outside Gishall Alongwith Associated Supportstructure , 420Kv, 4000A, 63Ka Sf6 To Air Bushing , 420 Kv, 4000 A, 63 Ka, Sf6 Gis Linefeeder Bay Module ( With Pir ) As Persection-Project, Technicalspecification , 420Kv, 4000 A, 63 Ka, Sf6 Gis Tie Baymodule ( With Pir ) As Persection-Project, Technicalspecification , Sf6 Gas Leakage Detector , Sf6 Gas Analyzer , Portable Partial Discharge Measurement Test Kitwith All Necessary Accessories, Industrial Grade Laptop And Licensedsoftware As Per Technicalspecification. , Sf6 Gas Processing Unit For 400Kv Gis Station , 400Kv Gis-Sf6 Gas Pressure Relief Device Assembly Of Each Type , Sf6pressuregaugecumswitch / Density Monitorsandpressureswitch As Applicable, Of Each Type-400Kv Gis , Couplingdeviceforpressuregaugecumswitchforconnectinggas Handling Plant Of Each Type-400Kv Gis , Rubbergaskets, ‚¬Å’Oã‚‚¬ÂRingsandsealsforsf6gasforgisenclosure Of Each Type-400Kv Gis , 400Kv Gis-Molecular Filter For Sf6 Gas With Filter Bags ( 5 % Of Totalweight ) , Control Valves For Sf6 Gas Of Each Type-400Kv Gis , 400Kv Gis-Sf6 Gas ( 5 % Of Total Gas Quantity ) , Locking Device To Keep The Dis-Connectors ( Isolators ) And Earthing / Fast Earthing Switches In Close Or Open Position In Caseof Removal Of The Driving Mechanism-400Kv Gis , Uhf Pd Sensors Of Each Type Along With Bnc Connector For 420Kv Gis , 400Kv Gis-Support Insulators ( Gas Through ) Of Each Type ( Complete Withmetal Ring Etc. ) Along With Associated Contacts And Shields , 400Kv Gis-Gas Barriers Of Each Type ( Complete With Metal Ring Etc. ) Along With Associated Contacts And Shields , 400Kv Gis- 4000A Sf6 To Air Bushing Complete In All Respect , Lcc Spares- Aux. Relays, Contactors, Push Buttons, Switches, Lamps, Annunciation Windows, Mcb, Fuses, Timers, Terminal Blocks Etc. Of Eachtype & Rating-400Kv Gis , 400Kv Gis-One Pole Of 4000A Circuit Breaker Without Pir Withinterrupter, Main Circuit, Enclosure And Operating Mechanism Completein All Respect , 400Kv Gis-One Pole Of 4000A Circuit Breaker With Pir With Interrupter, Main Circuit, Enclosure And Operating Mechanism Complete In Allrespect , Trip Coil Assembly With Resistor For420kv Gis Circuit Breaker ( Asapplicable ) , Closing Coil Assembly With Resistor For420kv Gis Circuit Breaker ( Asapplicable ) , Relays, Power Contactors, Push Buttons, Timers & Mcbs Etc. ( Asapplicable ) Of Each Type For 400Kv Gis Circuit Breaker , Auxiliary Switch Assembly Of Each Type For 420Kv Gis Circuit Breaker , 400Kv Gis Circuit Breaker-Operation Counter , 400Kv Gis Circuit Breaker-Hydraulic Operating Mechanism With Drivemotor ( For Hydraulic Operated Mechanism, If Applicable ) , Hydraulic Filter Of Each Type ( For Hydraulic Operated Mechanism, Ifpplicable ) -400Kv Gis Circuit Brekaer , 400Kv Gis Circuit Breaker- Hose Pipe Of Each Type ( As Applicable ) ( Forhydraulic Operated Mechanism, If Applicable ) , 400Kv Gis Circuit Breaker - N2 Accumulator ( For Hydraulic Operatedmechanism, If Applicable ) , Valves Of Each Type ( For Hydraulic Operated Mechanism, Ifapplicable ) -400Kv Gis Circuit Brekaer , Pipe Length ( Copper & Steel ) Of Each Size & Type ( For Hydraulicoperated Mechanism, If Applicable ) -400Kv Gis Circuit Brekaer , Pressure Switches Of Each Type ( For Hydraulic Operated Mechanism, Ifapplicable ) -400Kv Gis Circuit Brekaer , Pressure Gauge With Coupling Device Of Each Type ( For Hydraulicoperated Mechanism, If Applicable ) -400Kv Gis Circuit Brekaer , 400Kv Gis Circuit Breaker-Hydraulic Oil ( 5% Of Total Oil Quantity ) ( For Hydraulic Operated Mechanism, If Applicable ) , Pressure Relief Device Of Each Type ( For Hydraulic Operated Mechanism, If Applicable ) -400Kv Gis Circuit Brekaer , 400Kv Gis Circuit Breaker-Complete Spring Operating Mechanismincluding Charging Mechanism Etc. ( For Spring Operated Mechanism, Ifapplicable ) , 400Kv Gis Circuit Breaker- Complete Hydraulic-Spring Operatingmechanism Including Charging Mechanism Etc. ( For Hydraulic-Springoperated Mechanism, If Applicable ) , Pressure Switches Of Each Type For420kv Giscircuit Breaker ( Forhydraulic-Spring Operated Mechanism, Ifapplicable ) , Pressure Gauge With Coupling Device Of Each Type ( For Hydraulic-Springoperated Mechanism, If Applicable ) -400Kv Gis Circuit Brekaer , 400Kv Gis- Single Phase Of 4000A Disconnector Switch Including Maincircuit, Enclosure, Driving Mechanism And Support Insulator Etc., Complete In All Respect , 400Kv Gis- Single Phase Maintenance Earthing Switch Including Maincircuit, Enclosure, Driving Mechanism And Support Insulator Etc., Complete In All Respect , 400Kv Gis - Single Phase Fast Earthing Switch Including Main Circuit, Enclosure, Driving Mechanism And Support Insulator Etc., Complete Inall Respect , Open / Close Contactor Assembly, Timers, Key Interlock, Interlockingcoils, Relays, Push Buttons, Indicating Lamps, Power Contactors, Resistors, Fuses, Mcbs & Drive Control Cards Etc. ( As Applicable ) Oneof Each Type For One Complete Mom Box For 400Kv Gis Disconnectorswitch , Open / Close Contactor Assembly, Timers, Key Interlock, Interlockingcoils, Relays, Push Buttons, Indicating Lamps, Power Contactors, Resistors, Fuses, Mcbs & Drive Control Cards Etc. ( As Applicable ) Oneof Each Type For One Complete Mom Box For 400Kv Gis Maintenance Earthswitch , Open / Close Contactor Assembly, Timers, Key Interlock, Interlockingcoils, Relays, Push Buttons, Indicating Lamps, Power Contactors, Resistors, Fuses, Mcbs & Drive Control Cards Etc. ( As Applicable ) Oneof Each Type For One Complete Mom Box For 400Kv Gis Fast Earthingswitch , Limit Switches And Aux. Switches For One Complete Mom Box Fordisconnector-400Kv Gis , Limit Switches And Aux. Switches For One Complete Mom Box Formaintenance Earthing Switch-400Kv Gis , Limit Switches And Aux. Switches For One Complete Mom Box For Fastearthing Switch ( If Applicable ) -400Kv Gis , Drive Mechanism For 400Kv Gis Disconnector Switch , Drive Mechanism For 400Kv Gis Maintenance Earth Switch , Drive Mechanism For 400Kv Gis Fast Earthing Switch , Motor For Drive Mechanism For 400Kv Gis Disconnector Switch , Motor For Drive Mechanism For 400Kvgis Maintenance Earth Switch , Motor For Drive Mechanism For 400Kv Gis Fast Earthing Switch , 400Kv Gis- Single Phase Of Current Transformer ( 3 Cores, Type-Cta ) With Associated Enclosure And Primary Conductor Complete In Allrespect , 400Kv Gis- Single Phase Of Current Transformer ( 2 Cores, Type-Ctb ) With Associated Enclosure And Primary Conductor Complete In Allrespect , 400Kv Gis- Single Phase Vt With Associated Enclosure Complete In Allrespect , Services- Gis : 400Kv, Supervision Of Erection Of Gis , Services- Gis : 400Kv, Supervision Of Erection Of Gas Insulated Bus Duct , Services- Gis : 400Kv, Supervision Of Erection Of Sf6 To Air Bushing , Services- Gis : 400Kv, Testing & Commissioning Of Gis , Services- Gis : 400Kv, Final Successful Hv / Power Frequency Testing Of Gis Including Arranging Of Hv Test Kit Along With Operator , Services- Gis : Insulation Co-Ordination Studies For Gis System , Spares- Gis : 400Kv, Single Phase Bus Bar , Spares- Gis : 400Kv, Gis Metallic Enclosure , Spares- Gis : 400Kv, Expansion Bellows / Joints , Spares- Gis : 400Kv, Tee Bend , Spares- Gis : 400Kv, Angle Bend ( 135° ) , Spares- Gis : 400Kv, L-Bend , Services- Gis : Ref. Unit Price Of Gis Individual Item / Equipment - Services For Supervision Of Erection Of Gis , Services- Gis : Ref. Unit Price Of Gis Individual Item / Equipment - Services For Testing & Commissioning Of Gis , Services- Gis : 400Kv, Ref. Unit Price Of Gis Individual Item / Equipment - Hiring Charges Of Hv Test Kit With Operator

Corrigendum Details

Sr No CorrigendumDate Corrignedum CorrigendumType NewSubmissionDate
1 18-Aug-2023 Extension of due date upto 22-08-2023- SS20T Date 22-08-2023
2 21-Aug-2023 Corrigendum-04 Technical Bid 28-08-2023
3 21-Aug-2023 Corrigendum 04 SS20T Date 28-08-2023
4 28-Aug-2023 Corrigendum-05 Date 05-09-2023
5 31-Aug-2023 Corrigendum-06 -SS20T Technical Bid 05-09-2023
6 05-Sep-2023 CORRIGENDUM - 07 Date 08-09-2023

Key Value

Document Fees
Refer document
EMD
Refer document
Tender Value
Refer document

BOQ Items

Name of Work: 400kV & 220kV GIS at Jhangi & 400kV GIS at Wantoo- SS20T
Sl. No. Item Description
1420kV, 6000 A, 63 kA, SF6 GIS Bus barmodule as per Section-Project,Technical specification
2420KV, 4000A, 63KA SF6 TO AIR BUSHING
3420kV, 4000A,63kA, Single phase SF6 GasInsulated Bus Duct (GIB) outside GISHall alongwith associated supportstructure
4420 kV, 4000 A, 63 kA, SF6 GIS Linefeeder bay module(with PIR) as perSection-Project, Technicalspecification
5420 kV, 4000 A, 63 kA, SF6 GIS Linefeeder bay module(without PIR) as per Section-Project, Technicalspecification
6420kV, 4000 A, 63 kA, SF6 GIS Tie baymodule (without PIR) as per Section-Project, Technicalspecification
7420kV, 4000 A, 63 kA, SF6 GIS Tie baymodule(with PIR) as perSection-Project, Technicalspecification
8420kV, 4000 A, 63 kA, SF6 GIS ICT feederbay module as per Section-Project,Technical specification
9420kV, 4000 A, 63 kA, SF6 GIS Bus Reactor bay module as per Section-Project, Technicalspecification
10420kV, 4000 A, 63 kA, SF6 GIS AuxiliaryBus module for Spare Transformer as perSection-Project, Technicalspecification
11420kV, 4000 A, 63 kA, SF6 GIS AuxiliaryBus module for Spare Bus Reactor as perSection-Project, Technicalspecification
12Portable Partial Discharge measurement test kitwith all necessary accessories,Industrial Grade Laptop and licensedsoftware as per Technicalspecification.
13SF6 Gas Leakage Detector
14SF6 GAS ANALYZER
15SF6 Gas processing Unit for 400kV GIS station
16245kV, 1600 A, 50 kA, SF6 GIS ICT feederbay module as per Section-Project,Technical specification
17245kV,1600A, 50kA,3 Single phase/3Phase, SF6 Gas Insulated Bus Duct (GIB)outside GIS Hall alongwith associatedsupport structure(Quantity mentionedhere is for 3 Phase type)
18245kV, 1600A, 50kA Single phase SF6 to Air Bushing
19245KV, 1600 A, 50 KA, SF6 GIS AUXILIARY BUS MODULE FOR SPARE TRANSFORMERAS PER SECTION-PROJECT, TECHNICAL SPECIFICATION
20Controlled switching device for 420 kV, 3 phase circuit breaker
21245 kV, 3000A, 50kA, SF6 GIS Bus barmodule as per Section-Project,Technical specification
22245kV, 3000 A, 50 kA, SF6 GIS Buscoupler bay module as perSection-Project, Technicalspecification
23400KV GIS-SF6 GAS PRESSURE RELIEF DEVICE ASSEMBLY OF EACH TYPE
24SF6PRESSUREGAUGECUMSWITCH/DENSITY MONITORSANDPRESSURESWITCH AS APPLICABLE, OF EACH TYPE-400KV GIS
25COUPLINGDEVICEFORPRESSUREGAUGECUMSWITCHFORCONNECTINGGAS HANDLING PLANT OF EACH TYPE-400KV GIS
26RUBBERGASKETS,€ŒO€RINGSANDSEALSFORSF6GASFORGISENCLOSURE OF EACH TYPE-400KV GIS
27400KV GIS-MOLECULAR FILTER FOR SF6 GAS WITH FILTER BAGS (5 % OF TOTALWEIGHT)
28CONTROL VALVES FOR SF6 GAS OF EACH TYPE-400KV GIS
29400KV GIS-SF6 GAS (5 % OF TOTAL GAS QUANTITY)
30LOCKING DEVICE TO KEEP THE DIS-CONNECTORS (ISOLATORS)AND EARTHING/FAST EARTHING SWITCHES IN CLOSE OR OPEN POSITION IN CASEOF REMOVAL OF THE DRIVING MECHANISM-400KV GIS
31UHF PD SENSORS OF EACH TYPE ALONG WITH BNC CONNECTOR FOR 420KV GIS
32400KV GIS-SUPPORT INSULATORS (GAS THROUGH) OF EACH TYPE (COMPLETE WITHMETAL RING ETC.) ALONG WITH ASSOCIATED CONTACTS AND SHIELDS
33400KV GIS-GAS BARRIERS OF EACH TYPE (COMPLETE WITH METAL RING ETC.)ALONG WITH ASSOCIATED CONTACTS AND SHIELDS
34400KV GIS- 4000A SF6 TO AIR BUSHING COMPLETE IN ALL RESPECT
35LCC SPARES- AUX. RELAYS, CONTACTORS,PUSH BUTTONS, SWITCHES,LAMPS,ANNUNCIATION WINDOWS, MCB, FUSES,TIMERS, TERMINAL BLOCKS ETC. OF EACHTYPE & RATING-400kV GIS
36400KV GIS-ONE POLE OF 4000A CIRCUIT BREAKER WITHOUT PIR WITHINTERRUPTER, MAIN CIRCUIT, ENCLOSURE AND OPERATING MECHANISM COMPLETEIN ALL RESPECT
37400KV GIS-ONE POLE OF 4000A CIRCUIT BREAKER WITH PIR WITH INTERRUPTER,MAIN CIRCUIT, ENCLOSURE AND OPERATING MECHANISM COMPLETE IN ALLRESPECT
38Trip coil assembly with resistor for420kV GIS Circuit Breaker (asapplicable)
39Closing coil assembly with resistor for420kV GIS Circuit Breaker (asapplicable)
40RELAYS, POWER CONTACTORS, PUSH BUTTONS, TIMERS & MCBS ETC. (ASAPPLICABLE) OF EACH TYPE FOR 400KV GIS CIRCUIT BREAKER
41Auxiliary switch assembly of each type for 420kV GIS Circuit Breaker
42400KV GIS CIRCUIT BREAKER-OPERATION COUNTER
43400KV GIS CIRCUIT BREAKER-HYDRAULIC OPERATING MECHANISM WITH DRIVEMOTOR (FOR HYDRAULIC OPERATED MECHANISM, IF APPLICABLE)
44HYDRAULIC FILTER OF EACH TYPE (FOR HYDRAULIC OPERATED MECHANISM, IFPPLICABLE)-400KV GIS CIRCUIT BREKAER
45400KV GIS CIRCUIT BREAKER- HOSE PIPE OF EACH TYPE (AS APPLICABLE) (FORHYDRAULIC OPERATED MECHANISM, IF APPLICABLE)
46400KV GIS CIRCUIT BREAKER - N2 ACCUMULATOR (FOR HYDRAULIC OPERATEDMECHANISM, IF APPLICABLE)
47VALVES OF EACH TYPE (FOR HYDRAULIC OPERATED MECHANISM, IFAPPLICABLE)-400KV GIS CIRCUIT BREKAER
48PIPE LENGTH (COPPER & STEEL) OF EACH SIZE & TYPE (FOR HYDRAULICOPERATED MECHANISM, IF APPLICABLE)-400KV GIS CIRCUIT BREKAER
49PRESSURE SWITCHES OF EACH TYPE (FOR HYDRAULIC OPERATED MECHANISM, IFAPPLICABLE)-400KV GIS CIRCUIT BREKAER
50PRESSURE GAUGE WITH COUPLING DEVICE OF EACH TYPE (FOR HYDRAULICOPERATED MECHANISM, IF APPLICABLE)-400KV GIS CIRCUIT BREKAER
51400KV GIS CIRCUIT BREAKER-HYDRAULIC OIL (5% OF TOTAL OIL QUANTITY)(FOR HYDRAULIC OPERATED MECHANISM, IF APPLICABLE)
52PRESSURE RELIEF DEVICE OF EACH TYPE (FOR HYDRAULIC OPERATED MECHANISM,IF APPLICABLE)-400KV GIS CIRCUIT BREKAER
53400KV GIS CIRCUIT BREAKER-COMPLETE SPRING OPERATING MECHANISMINCLUDING CHARGING MECHANISM ETC. (FOR SPRING OPERATED MECHANISM, IFAPPLICABLE)
54400KV GIS CIRCUIT BREAKER- COMPLETE HYDRAULIC-SPRING OPERATINGMECHANISM INCLUDING CHARGING MECHANISM ETC. (FOR HYDRAULIC-SPRINGOPERATED MECHANISM, IF APPLICABLE)
55PRESSURE SWITCHES OF EACH TYPE FOR420KV GISCIRCUIT BREAKER (ForHydraulic-Spring Operated Mechanism, ifapplicable)
56PRESSURE GAUGE WITH COUPLING DEVICE OF EACH TYPE (FOR HYDRAULIC-SPRINGOPERATED MECHANISM, IF APPLICABLE)-400KV GIS CIRCUIT BREKAER
57400kV GIS- Single phase of 4000A disconnector switch including maincircuit, enclosure, driving mechanism and support insulator etc.,complete in all respect
58400KV GIS- SINGLE PHASE MAINTENANCE EARTHING SWITCH INCLUDING MAINCIRCUIT, ENCLOSURE, DRIVING MECHANISM AND SUPPORT INSULATOR ETC.,COMPLETE IN ALL RESPECT
59400KV GIS - SINGLE PHASE FAST EARTHING SWITCH INCLUDING MAIN CIRCUIT,ENCLOSURE, DRIVING MECHANISM AND SUPPORT INSULATOR ETC., COMPLETE INALL RESPECT
60OPEN/CLOSE CONTACTOR ASSEMBLY, TIMERS, KEY INTERLOCK, INTERLOCKINGCOILS, RELAYS, PUSH BUTTONS, INDICATING LAMPS, POWER CONTACTORS,RESISTORS, FUSES, MCBS & DRIVE CONTROL CARDS ETC. (AS APPLICABLE) ONEOF EACH TYPE FOR ONE COMPLETE MOM BOX FOR 400KV GIS DISCONNECTORSWITCH
61OPEN/CLOSE CONTACTOR ASSEMBLY, TIMERS, KEY INTERLOCK, INTERLOCKINGCOILS, RELAYS, PUSH BUTTONS, INDICATING LAMPS, POWER CONTACTORS,RESISTORS, FUSES, MCBS & DRIVE CONTROL CARDS ETC. (AS APPLICABLE) ONEOF EACH TYPE FOR ONE COMPLETE MOM BOX FOR 400KV GIS MAINTENANCE EARTHSWITCH
62OPEN/CLOSE CONTACTOR ASSEMBLY, TIMERS, KEY INTERLOCK, INTERLOCKINGCOILS, RELAYS, PUSH BUTTONS, INDICATING LAMPS, POWER CONTACTORS,RESISTORS, FUSES, MCBS & DRIVE CONTROL CARDS ETC. (AS APPLICABLE) ONEOF EACH TYPE FOR ONE COMPLETE MOM BOX FOR 400KV GIS FAST EARTHINGSWITCH
63LIMIT SWITCHES AND AUX. SWITCHES FOR ONE COMPLETE MOM BOX FORDISCONNECTOR-400KV GIS
64LIMIT SWITCHES AND AUX. SWITCHES FOR ONE COMPLETE MOM BOX FORMAINTENANCE EARTHING SWITCH-400KV GIS
65LIMIT SWITCHES AND AUX. SWITCHES FOR ONE COMPLETE MOM BOX FOR FASTEARTHING SWITCH (IF APPLICABLE)-400KV GIS
66DRIVE MECHANISM FOR 400KV GIS DISCONNECTOR SWITCH
67DRIVE MECHANISM FOR 400KV GIS MAINTENANCE EARTH SWITCH
68DRIVE MECHANISM FOR 400KV GIS FAST EARTHING SWITCH
69MOTOR FOR DRIVE MECHANISM FOR 400KV GIS DISCONNECTOR SWITCH
70MOTOR FOR DRIVE MECHANISM FOR 400KVGIS MAINTENANCE EARTH SWITCH
71MOTOR FOR DRIVE MECHANISM FOR 400KV GIS FAST EARTHING SWITCH
72400KV GIS- SINGLE PHASE OF CURRENT TRANSFORMER (3 CORES, TYPE-CTA)WITH ASSOCIATED ENCLOSURE AND PRIMARY CONDUCTOR COMPLETE IN ALLRESPECT
73400KV GIS- SINGLE PHASE OF CURRENT TRANSFORMER (2 CORES, TYPE-CTB)WITH ASSOCIATED ENCLOSURE AND PRIMARY CONDUCTOR COMPLETE IN ALLRESPECT
74400KV GIS- SINGLE PHASE VT WITH ASSOCIATED ENCLOSURE COMPLETE IN ALLRESPECT
75220KV GIS- CABLE CONNECTION ENCLOSURE WITH MAIN CIRCUIT
76220KV GIS-SF6 GAS PRESSURE RELIEF DEVICE ASSEMBLY OF EACH TYPE
77SF6PRESSUREGAUGECUMSWITCH/DENSITY MONITORSANDPRESSURESWITCH AS APPLICABLE, OF EACH TYPE-220KV GIS
78COUPLINGDEVICEFORPRESSUREGAUGECUMSWITCHFORCONNECTINGGAS HANDLING PLANT OF EACH TYPE-220KV GIS
79RUBBERGASKETS,€ŒO€RINGSANDSEALSFORSF6GASFORGISENCLOSURE OF EACH TYPE-220KV GIS
80220KV GIS-MOLECULAR FILTER FOR SF6 GAS WITH FILTER BAGS (5 % OF TOTALWEIGHT)
81CONTROL VALVES FOR SF6 GAS OF EACH TYPE-220KV GIS
82220KV GIS-SF6 GAS (5 % OF TOTAL GAS QUANTITY)
83LOCKING DEVICE TO KEEP THE DIS-CONNECTORS (ISOLATORS)AND EARTHING/FAST EARTHING SWITCHES (AS APPLICABLE) IN CLOSE OR OPENPOSITION IN CASE OF REMOVAL OF THE DRIVING MECHANISM-220KV GIS
84UHF PD SENSORS OF EACH TYPE ALONG WITH BNC CONNECTOR FOR 245KV GIS
85220KV GIS-SUPPORT INSULATORS (GAS THROUGH) OF EACH TYPE (COMPLETE WITHMETAL RING ETC.) ALONG WITH ASSOCIATED CONTACTS AND SHIELDS
86220KV GIS-GAS BARRIERS OF EACH TYPE (COMPLETE WITH METAL RING ETC.)ALONG WITH ASSOCIATED CONTACTS AND SHIELDS
87220KV GIS- 1600A SF6 TO AIR BUSHING COMPLETE IN ALL RESPECT
88LCC SPARES- AUX. RELAYS, CONTACTORS,PUSH BUTTONS, SWITCHES, LAMPS,ANNUNCIATION WINDOWS, MCB, FUSES,TIMERS, TERMINAL BLOCKS ETC. OF EACHTYPE & RATING-220kV GIS
89220KV GIS-ONE POLE OF 1600A CIRCUIT BREAKER WITH INTERRUPTER, MAINCIRCUIT, ENCLOSURE AND OPERATING MECHANISM COMPLETE IN ALL RESPECT
90220KV GIS-ONE POLE OF 2500A CIRCUIT BREAKER WITH INTERRUPTER, MAINCIRCUIT, ENCLOSURE AND OPERATING MECHANISM COMPLETE IN ALL RESPECT
91220KV GIS-ONE POLE OF 3000A CIRCUIT BREAKER WITH INTERRUPTER, MAINCIRCUIT, ENCLOSURE AND OPERATING MECHANISM COMPLETE IN ALL RESPECT
92Trip coil assembly with resistor for245kV GIS Circuit Breaker (asapplicable)
93Closing coil assembly with resistor for245kV GIS Circuit Breaker (asapplicable)
94RELAYS, POWER CONTACTORS, PUSH BUTTONS, TIMERS & MCBS ETC. (ASAPPLICABLE) OF EACH TYPE FOR 220KV GIS CIRCUIT BREAKER
95Auxiliary switch assembly of each type for 245kV GIS Circuit Breaker
96220KV GIS CIRCUIT BREAKER-OPERATION COUNTER
97220KV GIS CIRCUIT BREAKER-HYDRAULIC OPERATING MECHANISM WITH DRIVEMOTOR (FOR HYDRAULIC OPERATED MECHANISM, IF APPLICABLE)
98HYDRAULIC FILTER OF EACH TYPE (FOR HYDRAULIC OPERATED MECHANISM, IFPPLICABLE)-220KV GIS CIRCUIT BREKAER
99220KV GIS CIRCUIT BREAKER- HOSE PIPE OF EACH TYPE (AS APPLICABLE) (FORHYDRAULIC OPERATED MECHANISM, IF APPLICABLE)
100220KV GIS CIRCUIT BREAKER - N2 ACCUMULATOR (FOR HYDRAULIC OPERATEDMECHANISM, IF APPLICABLE)
101VALVES OF EACH TYPE (FOR HYDRAULIC OPERATED MECHANISM, IFAPPLICABLE)-220KV GIS CIRCUIT BREKAER
102PIPE LENGTH (COPPER & STEEL) OF EACH SIZE & TYPE (FOR HYDRAULICOPERATED MECHANISM, IF APPLICABLE)-220KV GIS CIRCUIT BREKAER
103PRESSURE SWITCHES OF EACH TYPE (FOR HYDRAULIC OPERATED MECHANISM, IFAPPLICABLE)-220KV GIS CIRCUIT BREKAER
104PRESSURE GAUGE WITH COUPLING DEVICE OF EACH TYPE (FOR HYDRAULICOPERATED MECHANISM, IF APPLICABLE)-220KV GIS CIRCUIT BREKAER
105220KV GIS CIRCUIT BREAKER-HYDRAULIC OIL (5% OF TOTAL OIL QUANTITY)(FOR HYDRAULIC OPERATED MECHANISM, IF APPLICABLE)
106PRESSURE RELIEF DEVICE OF EACH TYPE (FOR HYDRAULIC OPERATED MECHANISM,IF APPLICABLE)-220KV GIS CIRCUIT BREKAER
107220KV GIS CIRCUIT BREAKER-COMPLETE SPRING OPERATING MECHANISMINCLUDING CHARGING MECHANISM ETC. (FOR SPRING OPERATED MECHANISM, IFAPPLICABLE)
108220KV GIS CIRCUIT BREAKER- COMPLETE HYDRAULIC-SPRING OPERATINGMECHANISM INCLUDING CHARGING MECHANISM ETC. (FOR HYDRAULIC-SPRINGOPERATED MECHANISM, IF APPLICABLE)
109PRESSURE SWITCHES OF EACH TYPE (FOR HYDRAULIC-SPRING OPERATEDMECHANISM, IF APPLICABLE)-220KV GIS CIRCUIT BREAKER
110PRESSURE GAUGE WITH COUPLING DEVICE OF EACH TYPE (FOR HYDRAULIC-SPRINGOPERATED MECHANISM, IF APPLICABLE)-220KV GIS CIRCUIT BREKAER
111220kV GIS- Three phase of 1600Adisconnector switch including maincircuit, enclosure, driving mechanismand support insulator etc., complete inall respect
112220kV GIS- Three phase of 2500Adisconnector switch including maincircuit, enclosure, driving mechanismand support insulator etc., complete inall respect
113220kV GIS- Three phase of 3000Adisconnector switch including maincircuit, enclosure, driving mechanismand support insulator etc., complete inall respect
114220KV GIS- THREE PHASE MAINTENANCE EARTHING SWITCH INCLUDING MAINCIRCUIT, ENCLOSURE, DRIVING MECHANISM AND SUPPORT INSULATOR ETC.,COMPLETE IN ALL RESPECT
115220KV GIS - THREE PHASE FAST EARTHING SWITCH INCLUDING MAIN CIRCUIT,ENCLOSURE, DRIVING MECHANISM AND SUPPORT INSULATOR ETC., COMPLETE INALL RESPECT
116OPEN/CLOSE CONTACTOR ASSEMBLY, TIMERS, KEY INTERLOCK, INTERLOCKINGCOILS, RELAYS, PUSH BUTTONS, INDICATING LAMPS, POWER CONTACTORS,RESISTORS, FUSES, MCBS & DRIVE CONTROL CARDS ETC. (AS APPLICABLE) ONEOF EACH TYPE FOR ONE COMPLETE MOM BOX FOR 220KV GIS DISCONNECTORSWITCH
117OPEN/CLOSE CONTACTOR ASSEMBLY, TIMERS, KEY INTERLOCK, INTERLOCKINGCOILS, RELAYS, PUSH BUTTONS, INDICATING LAMPS, POWER CONTACTORS,RESISTORS, FUSES, MCBS & DRIVE CONTROL CARDS ETC. (AS APPLICABLE) ONEOF EACH TYPE FOR ONE COMPLETE MOM BOX FOR 220KV GIS MAINTENANCE EARTHSWITCH
118OPEN/CLOSE CONTACTOR ASSEMBLY, TIMERS, KEY INTERLOCK, INTERLOCKINGCOILS, RELAYS, PUSH BUTTONS, INDICATING LAMPS, POWER CONTACTORS,RESISTORS, FUSES, MCBS & DRIVE CONTROL CARDS ETC. (AS APPLICABLE) ONEOF EACH TYPE FOR ONE COMPLETE MOM BOX FOR 220KV GIS FAST EARTHINGSWITCH
119LIMIT SWITCHES AND AUX. SWITCHES FOR ONE COMPLETE MOM BOX FORDISCONNECTOR-220KV GIS
120LIMIT SWITCHES AND AUX. SWITCHES FOR ONE COMPLETE MOM BOX FORMAINTENANCE EARTHING SWITCH-220KV GIS
121LIMIT SWITCHES AND AUX. SWITCHES FOR ONE COMPLETE MOM BOX FOR FASTEARTHING SWITCH (IF APPLICABLE)-220KV GIS
122DRIVE MECHANISM FOR 220KV GIS DISCONNECTOR SWITCH
123DRIVE MECHANISM FOR 220KV GIS MAINTENANCE EARTH SWITCH
124DRIVE MECHANISM FOR 220KV GIS FAST EARTHING SWITCH
125MOTOR FOR DRIVE MECHANISM FOR 220KV GIS DISCONNECTOR SWITCH
126MOTOR FOR DRIVE MECHANISM FOR 220KVGIS MAINTENANCE EARTH SWITCH
127MOTOR FOR DRIVE MECHANISM FOR 220KV GIS FAST EARTHING SWITCH
128220KV GIS- SINGLE PHASE OF CURRENT TRANSFORMER (4 CORES) WITHASSOCIATED ENCLOSURE AND PRIMARY CONDUCTOR COMPLETE IN ALL RESPECT
129220KV GIS- SINGLE PHASE VT WITH ASSOCIATED ENCLOSURE COMPLETE IN ALLRESPECT
130220KV GIS- SINGLE PHASE GAS INSULATED SURGE ARRESTER WITH ASSOCIATEDENCLOSURE AND INSULATOR COMPLETE IN ALL RESPECT
131220KV GIS- SURGE COUNTER/ MONITOR
132SERVICES- GIS : 400KV, SUPERVISION OF ERECTION OF GIS
133SERVICES- GIS : 400KV, SUPERVISION OF ERECTION OF GAS INSULATED BUS DUCT
134SERVICES- GIS : 400KV, SUPERVISION OF ERECTION OF SF6 TO AIR BUSHING
135SERVICES- GIS : 400KV, TESTING & COMMISSIONING OF GIS
136SERVICES- GIS : 400KV, FINAL SUCCESSFUL HV/ POWER FREQUENCY TESTING OF GIS INCLUDING ARRANGING OF HV TEST KIT ALONG WITH OPERATOR
137SERVICES- GIS : INSULATION CO-ORDINATION STUDIES FOR GIS SYSTEM
138SERVICES- GIS : 220KV, SUPERVISION OF ERECTION OF GIS
139SERVICES- GIS : 220KV, SUPERVISION OF ERECTION OF GAS INSULATED BUS DUCT
140SERVICES- GIS : 220KV, SUPERVISION OF ERECTION OF SF6 TO AIR BUSHING
141SERVICES- GIS : 220KV, TESTING & COMMISSIONING OF GIS
142SERVICES- GIS : 220KV, FINAL SUCCESSFUL HV/ POWER FREQUENCY TESTING OF GIS INCLUDING ARRANGING OF HV TEST KIT ALONG WITH OPERATOR
143SPARES- GIS : 400KV, SINGLE PHASE BUS BAR
144SPARES- GIS : 400KV, GIS METALLIC ENCLOSURE
145SPARES- GIS : 400KV, EXPANSION BELLOWS/ JOINTS
146SPARES- GIS : 400KV, TEE BEND
147SPARES- GIS : 400KV, ANGLE BEND (135°)
148SPARES- GIS : 400KV, L-BEND
149SPARES- GIS : 220KV, SINGLE PHASE BUS BAR
150SPARES- GIS : 220KV, GIS METALLIC ENCLOSURE
151SPARES- GIS : 220KV, EXPANSION BELLOWS/ JOINTS
152SPARES- GIS : 220KV, TEE BEND
153SPARES- GIS : 220KV, ANGLE BEND (135°)
154SPARES- GIS : 220KV, L-BEND
155SERVICES- GIS : REF. UNIT PRICE OF GIS INDIVIDUAL ITEM/ EQUIPMENT - SERVICES FOR SUPERVISION OF ERECTION OF GIS
156SERVICES- GIS : REF. UNIT PRICE OF GIS INDIVIDUAL ITEM/ EQUIPMENT - SERVICES FOR TESTING & COMMISSIONING OF GIS
157SERVICES- GIS : 400KV, REF. UNIT PRICE OF GIS INDIVIDUAL ITEM/ EQUIPMENT - HIRING CHARGES OF HV TEST KIT WITH OPERATOR
158SERVICES- GIS : 220KV, REF. UNIT PRICE OF GIS INDIVIDUAL ITEM/ EQUIPMENT - HIRING CHARGES OF HV TEST KIT WITH OPERATOR
159420KV, 6300A,63KA GIS BUSBAR MODULE EXTENSION
160420kV, 4000A,63kA, Single phase SF6 GasInsulated Bus Duct (GIB) outside GISHall alongwith associated supportstructure
161420KV, 4000A, 63KA SF6 TO AIR BUSHING
162420 kV, 4000 A, 63 kA, SF6 GIS Linefeeder bay module(with PIR) as perSection-Project, Technicalspecification
163420kV, 4000 A, 63 kA, SF6 GIS Tie baymodule(with PIR) as perSection-Project, Technicalspecification
164SF6 Gas Leakage Detector
165SF6 GAS ANALYZER
166Portable Partial Discharge measurement test kitwith all necessary accessories,Industrial Grade Laptop and licensedsoftware as per Technicalspecification.
167SF6 Gas processing Unit for 400kV GIS station
168400KV GIS-SF6 GAS PRESSURE RELIEF DEVICE ASSEMBLY OF EACH TYPE
169SF6PRESSUREGAUGECUMSWITCH/DENSITY MONITORSANDPRESSURESWITCH AS APPLICABLE, OF EACH TYPE-400KV GIS
170COUPLINGDEVICEFORPRESSUREGAUGECUMSWITCHFORCONNECTINGGAS HANDLING PLANT OF EACH TYPE-400KV GIS
171RUBBERGASKETS,€ŒO€RINGSANDSEALSFORSF6GASFORGISENCLOSURE OF EACH TYPE-400KV GIS
172400KV GIS-MOLECULAR FILTER FOR SF6 GAS WITH FILTER BAGS (5 % OF TOTALWEIGHT)
173CONTROL VALVES FOR SF6 GAS OF EACH TYPE-400KV GIS
174400KV GIS-SF6 GAS (5 % OF TOTAL GAS QUANTITY)
175LOCKING DEVICE TO KEEP THE DIS-CONNECTORS (ISOLATORS)AND EARTHING/FAST EARTHING SWITCHES IN CLOSE OR OPEN POSITION IN CASEOF REMOVAL OF THE DRIVING MECHANISM-400KV GIS
176UHF PD SENSORS OF EACH TYPE ALONG WITH BNC CONNECTOR FOR 420KV GIS
177400KV GIS-SUPPORT INSULATORS (GAS THROUGH) OF EACH TYPE (COMPLETE WITHMETAL RING ETC.) ALONG WITH ASSOCIATED CONTACTS AND SHIELDS
178400KV GIS-GAS BARRIERS OF EACH TYPE (COMPLETE WITH METAL RING ETC.)ALONG WITH ASSOCIATED CONTACTS AND SHIELDS
179400KV GIS- 4000A SF6 TO AIR BUSHING COMPLETE IN ALL RESPECT
180LCC SPARES- AUX. RELAYS, CONTACTORS,PUSH BUTTONS, SWITCHES,LAMPS,ANNUNCIATION WINDOWS, MCB, FUSES,TIMERS, TERMINAL BLOCKS ETC. OF EACHTYPE & RATING-400kV GIS
181400KV GIS-ONE POLE OF 4000A CIRCUIT BREAKER WITHOUT PIR WITHINTERRUPTER, MAIN CIRCUIT, ENCLOSURE AND OPERATING MECHANISM COMPLETEIN ALL RESPECT
182400KV GIS-ONE POLE OF 4000A CIRCUIT BREAKER WITH PIR WITH INTERRUPTER,MAIN CIRCUIT, ENCLOSURE AND OPERATING MECHANISM COMPLETE IN ALLRESPECT
183Trip coil assembly with resistor for420kV GIS Circuit Breaker (asapplicable)
184Closing coil assembly with resistor for420kV GIS Circuit Breaker (asapplicable)
185RELAYS, POWER CONTACTORS, PUSH BUTTONS, TIMERS & MCBS ETC. (ASAPPLICABLE) OF EACH TYPE FOR 400KV GIS CIRCUIT BREAKER
186Auxiliary switch assembly of each type for 420kV GIS Circuit Breaker
187400KV GIS CIRCUIT BREAKER-OPERATION COUNTER
188400KV GIS CIRCUIT BREAKER-HYDRAULIC OPERATING MECHANISM WITH DRIVEMOTOR (FOR HYDRAULIC OPERATED MECHANISM, IF APPLICABLE)
189HYDRAULIC FILTER OF EACH TYPE (FOR HYDRAULIC OPERATED MECHANISM, IFPPLICABLE)-400KV GIS CIRCUIT BREKAER
190400KV GIS CIRCUIT BREAKER- HOSE PIPE OF EACH TYPE (AS APPLICABLE) (FORHYDRAULIC OPERATED MECHANISM, IF APPLICABLE)
191400KV GIS CIRCUIT BREAKER - N2 ACCUMULATOR (FOR HYDRAULIC OPERATEDMECHANISM, IF APPLICABLE)
192VALVES OF EACH TYPE (FOR HYDRAULIC OPERATED MECHANISM, IFAPPLICABLE)-400KV GIS CIRCUIT BREKAER
193PIPE LENGTH (COPPER & STEEL) OF EACH SIZE & TYPE (FOR HYDRAULICOPERATED MECHANISM, IF APPLICABLE)-400KV GIS CIRCUIT BREKAER
194PRESSURE SWITCHES OF EACH TYPE (FOR HYDRAULIC OPERATED MECHANISM, IFAPPLICABLE)-400KV GIS CIRCUIT BREKAER
195PRESSURE GAUGE WITH COUPLING DEVICE OF EACH TYPE (FOR HYDRAULICOPERATED MECHANISM, IF APPLICABLE)-400KV GIS CIRCUIT BREKAER
196400KV GIS CIRCUIT BREAKER-HYDRAULIC OIL (5% OF TOTAL OIL QUANTITY)(FOR HYDRAULIC OPERATED MECHANISM, IF APPLICABLE)
197PRESSURE RELIEF DEVICE OF EACH TYPE (FOR HYDRAULIC OPERATED MECHANISM,IF APPLICABLE)-400KV GIS CIRCUIT BREKAER
198400KV GIS CIRCUIT BREAKER-COMPLETE SPRING OPERATING MECHANISMINCLUDING CHARGING MECHANISM ETC. (FOR SPRING OPERATED MECHANISM, IFAPPLICABLE)
199400KV GIS CIRCUIT BREAKER- COMPLETE HYDRAULIC-SPRING OPERATINGMECHANISM INCLUDING CHARGING MECHANISM ETC. (FOR HYDRAULIC-SPRINGOPERATED MECHANISM, IF APPLICABLE)
200PRESSURE SWITCHES OF EACH TYPE FOR420KV GISCIRCUIT BREAKER (ForHydraulic-Spring Operated Mechanism, ifapplicable)
201PRESSURE GAUGE WITH COUPLING DEVICE OF EACH TYPE (FOR HYDRAULIC-SPRINGOPERATED MECHANISM, IF APPLICABLE)-400KV GIS CIRCUIT BREKAER
202400kV GIS- Single phase of 4000A disconnector switch including maincircuit, enclosure, driving mechanism and support insulator etc.,complete in all respect
203400KV GIS- SINGLE PHASE MAINTENANCE EARTHING SWITCH INCLUDING MAINCIRCUIT, ENCLOSURE, DRIVING MECHANISM AND SUPPORT INSULATOR ETC.,COMPLETE IN ALL RESPECT
204400KV GIS - SINGLE PHASE FAST EARTHING SWITCH INCLUDING MAIN CIRCUIT,ENCLOSURE, DRIVING MECHANISM AND SUPPORT INSULATOR ETC., COMPLETE INALL RESPECT
205OPEN/CLOSE CONTACTOR ASSEMBLY, TIMERS, KEY INTERLOCK, INTERLOCKINGCOILS, RELAYS, PUSH BUTTONS, INDICATING LAMPS, POWER CONTACTORS,RESISTORS, FUSES, MCBS & DRIVE CONTROL CARDS ETC. (AS APPLICABLE) ONEOF EACH TYPE FOR ONE COMPLETE MOM BOX FOR 400KV GIS DISCONNECTORSWITCH
206OPEN/CLOSE CONTACTOR ASSEMBLY, TIMERS, KEY INTERLOCK, INTERLOCKINGCOILS, RELAYS, PUSH BUTTONS, INDICATING LAMPS, POWER CONTACTORS,RESISTORS, FUSES, MCBS & DRIVE CONTROL CARDS ETC. (AS APPLICABLE) ONEOF EACH TYPE FOR ONE COMPLETE MOM BOX FOR 400KV GIS MAINTENANCE EARTHSWITCH
207OPEN/CLOSE CONTACTOR ASSEMBLY, TIMERS, KEY INTERLOCK, INTERLOCKINGCOILS, RELAYS, PUSH BUTTONS, INDICATING LAMPS, POWER CONTACTORS,RESISTORS, FUSES, MCBS & DRIVE CONTROL CARDS ETC. (AS APPLICABLE) ONEOF EACH TYPE FOR ONE COMPLETE MOM BOX FOR 400KV GIS FAST EARTHINGSWITCH
208LIMIT SWITCHES AND AUX. SWITCHES FOR ONE COMPLETE MOM BOX FORDISCONNECTOR-400KV GIS
209LIMIT SWITCHES AND AUX. SWITCHES FOR ONE COMPLETE MOM BOX FORMAINTENANCE EARTHING SWITCH-400KV GIS
210LIMIT SWITCHES AND AUX. SWITCHES FOR ONE COMPLETE MOM BOX FOR FASTEARTHING SWITCH (IF APPLICABLE)-400KV GIS
211DRIVE MECHANISM FOR 400KV GIS DISCONNECTOR SWITCH
212DRIVE MECHANISM FOR 400KV GIS MAINTENANCE EARTH SWITCH
213DRIVE MECHANISM FOR 400KV GIS FAST EARTHING SWITCH
214MOTOR FOR DRIVE MECHANISM FOR 400KV GIS DISCONNECTOR SWITCH
215MOTOR FOR DRIVE MECHANISM FOR 400KVGIS MAINTENANCE EARTH SWITCH
216MOTOR FOR DRIVE MECHANISM FOR 400KV GIS FAST EARTHING SWITCH
217400KV GIS- SINGLE PHASE OF CURRENT TRANSFORMER (3 CORES, TYPE-CTA)WITH ASSOCIATED ENCLOSURE AND PRIMARY CONDUCTOR COMPLETE IN ALLRESPECT
218400KV GIS- SINGLE PHASE OF CURRENT TRANSFORMER (2 CORES, TYPE-CTB)WITH ASSOCIATED ENCLOSURE AND PRIMARY CONDUCTOR COMPLETE IN ALLRESPECT
219400KV GIS- SINGLE PHASE VT WITH ASSOCIATED ENCLOSURE COMPLETE IN ALLRESPECT
220SERVICES- GIS : 400KV, SUPERVISION OF ERECTION OF GIS
221SERVICES- GIS : 400KV, SUPERVISION OF ERECTION OF GAS INSULATED BUS DUCT
222SERVICES- GIS : 400KV, SUPERVISION OF ERECTION OF SF6 TO AIR BUSHING
223SERVICES- GIS : 400KV, TESTING & COMMISSIONING OF GIS
224SERVICES- GIS : 400KV, FINAL SUCCESSFUL HV/ POWER FREQUENCY TESTING OF GIS INCLUDING ARRANGING OF HV TEST KIT ALONG WITH OPERATOR
225SERVICES- GIS : INSULATION CO-ORDINATION STUDIES FOR GIS SYSTEM
226SPARES- GIS : 400KV, SINGLE PHASE BUS BAR
227SPARES- GIS : 400KV, GIS METALLIC ENCLOSURE
228SPARES- GIS : 400KV, EXPANSION BELLOWS/ JOINTS
229SPARES- GIS : 400KV, TEE BEND
230SPARES- GIS : 400KV, ANGLE BEND (135°)
231SPARES- GIS : 400KV, L-BEND
232SERVICES- GIS : REF. UNIT PRICE OF GIS INDIVIDUAL ITEM/ EQUIPMENT - SERVICES FOR SUPERVISION OF ERECTION OF GIS
233SERVICES- GIS : REF. UNIT PRICE OF GIS INDIVIDUAL ITEM/ EQUIPMENT - SERVICES FOR TESTING & COMMISSIONING OF GIS
234SERVICES- GIS : 400KV, REF. UNIT PRICE OF GIS INDIVIDUAL ITEM/ EQUIPMENT - HIRING CHARGES OF HV TEST KIT WITH OPERATOR