Tender For Repair/Replacement Of Internal Electric With Fittings And Fixtures At Chakbama Military Station Under Age(I) Zakhama., zakhama-Nagaland

Military Engineer Services-MES has published Tender For Repair/Replacement Of Internal Electric With Fittings And Fixtures At Chakbama Military Station Under Age(I) Zakhama.. Submission Date for this Tender is 26-08-2023. Electrical Maintenance Tenders in zakhama Nagaland. Bidders can get complete Tender details and download the document.




Tender Notice

38911198
Corrigendum : Tender For Repair/Replacement Of Internal Electric With Fittings And Fixtures At Chakbama Military Station Under Age(I) Zakhama.
Open Tender
Indian
Nagaland
zakhama
26-08-2023

Tender Details

Repair/Replacement Of Internal Electric With Fittings And Fixtures At Chakbama Military Station Under Age(I) Zakhama.

Corrigendum Details

Sr No CorrigendumDate Corrignedum CorrigendumType NewSubmissionDate
1 14-Aug-2023 Bid Auto Extn Corrigendum Bid Auto Extn Corrigendum 21-08-2023
2 21-Aug-2023 Bid Auto Extn Corrigendum Bid Auto Extn Corrigendum 26-08-2023

Key Value

Document Fees
INR 500 /-
EMD
INR 18000.0 /-
Tender Value
Refer document

BOQ Items

NAME OF WORK : REPAIR/REPLACEMENT OF INTERNAL ELECTRIC WITH FITTINGS AND FIXTURES AT CHAKBAMA MILITARY STATION UNDER AGE(I) ZAKHAMA.
Sl. No. Item Description
1Taking down carefully any type of point wiring (light, fan, bell, socket or power), complete excluding fittings but includingswitches, ceiling roses, pendants, regulators, sockets, etc.and making good disturbed surfaces of walls, ceiling, floors etc to match with existing surface complete all as specified and as directed.
2M&L for point wiring with 1.5 sqmm, single core, PVC insulated and PVC unsheathedFRLS cable, 1100 volts grade IS-694marked, with multistranded copper conductors and earthcontinuity wire with 1.5 Sqmm copper conductor cable (including connecting to earth dolly)laid/fixed with and including PVC Casing and Caping on walls/ceiling, and with PVC switch board for mounting switches/socket etc for one light/fan/exhaust fan point controlled by one number one way 5 Amp switch complete all as specified and as directed.
3Allas peritem serial No 02 here-in-before but for One 3 pin 5 Ampsocket outlet on same board with other switches.
4Allas per item serial No 02here-in-before butfor One 3 pin 5 Amp switch socket outlet on independent board.
5All as per item serial No 02 here-in-before but with 2.5 Sqmm single core multistranded copper conductor cableand earthcontinuity wire with 2.5 Sqmm cable for 6 pin 15 Amp socket outlet on independent board.
6Allas per item serial No 02 here-in-before butfor One bell point controlled by one switch 5 Amps bell push.
7S & F switch piano, flush type single pole one way 5 Amps 230 volt complete all as specified and as directed.
8S & F in repairs, switch piano, flush type single pole one way 16 Amps 230 volt complete all as specified and as directed.
9S&F socket outlet 3 pin, 2-in-1, 5 Amps, flush typecomplete all as specified and as directed.
10S & F switch socket combination outlet 5 pin, 2-in-1, 5 Amp flush type complete all as specified and as directed.
11S & F switch socket combination, multipurpose, 2 in 1, 6 pin, 5 & 16 Amp flush type complete all as specified and as directed.
12S & F in repairs, socket outlet, multipurpose, 2 in 1, 6 pin, 5 & 16 Amp flush type complete all as specified and as directed.
13S & F ceiling rose surface bakelite, 65x50mm three terminal complete all as specified and as directed.
14S & F lamp holder, insulated, PVC / polycarbonate /bakelite bodyincluding 10W LED lampscomplete all as specified and as directed.
15S & F stepped type electronic fan regulator, two module size, flush type complete all as specified and as directed.
16Fixing only serviceable fan regulator obtain fromtaking out of point wiringcomplete all as specified and as directed.
17S&F bell push, flush type, 5 Amps complete all as specified and as directed.
18S & F call bell Ding Dong AC ,230 volts single pole complete all as specified and as directed.
19S&F in repairs, LED box type fitting of MAXOLED batten pre-wired including LED tube 1x20W ,fixed with PVC insulated and sheathed 1100 volt grade flexible copper cablecomplete all as specified and as directed. Make:- Havells Model-LHLDDCXCML8Q020 +LHFXCENNTN1W020 or equivalent model of make Philips /GE/Crompton
20S&F in repairs Environmental friendly, ultra modern, energy saving, surface mounted, decorative hexagonal bulk head black-lit LED10 W -IP-66 luminaire comprising of high brightness LEDs complete all as specified and as directed. Make:- HavellsModel HEXAFT10WLED857SSYMBOPC or equivalent Model of make : Philips /Crompton /GE.
21S&F in repairs,LED Downlight Aesthetically designed, decorative recess mounted 8 W Round 6500 K Concealed BoxLED (Round) spot light for low ceiling height applications complete all as specified and as directed. Make : Philips /Crompton /GE.
22S&F in repairs, 34 watt LED recessed mountedluminaire with high brightness SMD LEDs as light source, suitable for Armstrong/Grid ceiling and fixture size in mm (LxWxH) 595x595x70mm complete all as specified and as directed. Make : Havells Model-PLUTONEO2x2PLR34WLED840S/ PLUTONEO2x2PLR34WLED857S or equivalent model in make of Philips/ Crompton/Bajaj
23S&F PVC rectangular block for mounting, switches, sockets, fan regulator etc. with 3 mmthick plastic laminated sheet cover of size 250 mm x 200 mm and 50 mm deep complete all as specified and as directed.
24S&F PVC rectangular block for mounting, switches, sockets, fan regulator etc. with 3 mmthick plastic laminated sheet cover of size 100 mm x 100 mm and 50 mm deep complete all as specified and as directed.
25S & F in repairs, single pole & neutral DBs 8 Ways, double door, protection class IP-43 suitable for mounting MCB, DBs conforming to IS-13032, IS-8623, BS-5484 with min 100 Amp rating copper bus bar complete all as specified and as directed. Make :- Legrand Cat No 5076 11 or equivalent model in Siemens / Schneider
26S & F single pole & neutral DBs 4 Ways, double door, protection class IP-43 suitable for mounting MCB, DBs conforming to IS-13032, IS-8623, BS-5484 with min 100 Amp rating copper bus bar complete all as specified and as directed. Make :- Legrand Cat No 5076 10 or equivalent model in Siemens / Schneider/L&T
27S & F sheet metal enclosurewhen MCBto be used 2 way, Single pole & neutralwithout bus barcomplete all as specified and asdirected.
28S&F MCBs, SPN 6 to 32 Amps, 10 KA,"C" curve IS/IEC 60898-1 2002 marked fixing in DBs complete all as specified and as directed. Make :- Legrand Model 4086 09 to 17 or equivalent model in Siemens / Schneider/L&T
29S&F MCBs, SP 6 to 32 Amps, 10 KA, "C" curve IS/IEC 60898-1 2002 marked fixing in DBs complete all as specified and as directed. Make :-Legrand Model 4085 90 to 95 orequivalent model in Siemens / Schneider/L&T
30S&Fin repairs, MCBs, SP 6 to 32 Amps, 10 KA, "C" curve IS/IEC 60898-1 2002 marked fixing in DBs complete all as specified and as directed. Make :-Legrand Model 4085 90 to 95 orequivalent model in Siemens / Schneider/L&T
31M&L for Sub main wiring with 2 runs of 4.0 sqmm, single core, FR-LSH PVC insulated & unsheathed cable conforming to IS-694, 1100 volts with copper conductor multi stranded drawn in and including 20mm dia non metallic PVC grey conduit with all accessories such as Tees, Elbows, junction box, reducers etc as requied alongwith one run of 4.0 sqmm single core FR-LSHPVC insulated & unsheathed copper conductor as continuos earth wire dolly and connecting to existing main switch board / distribution board of each building / qtr as ordered and testing on completion including taking down old submain wiring and type of conduit complete all as specified and directed. (Note: 2 run of 4 Sqmm cable and 1 run of 4 Sqmm cable along with conduit altogether shall be measured as one unit.)
32M&L for Sub main wiring with 2 runs of 6.0 sqmm, single core, FR-LSH PVC insulated & unsheathed cable conforming to IS-694, 1100 volts with copper conductor multi stranded drawn in and including 20mm dia non metallic PVC grey conduit with all accessories such as Tees, Elbows, junction box, reducers etc as requied alongwith one run of 6.0 sqmm single core FR-LSHPVC insulated & unsheathed copper conductor as continuos earth wire dolly and connecting to existing main switch board / distribution board of each building / qtr as ordered and testing on completion including taking down old submain wiring and type of conduit complete all as specified and directed. (Note: 2 run of 6 Sqmm cable and 1 run of 6 Sqmm cable along with conduit altogether shall be measured as one unit.)
33S&F 1100 volts grade heavy duty flat cable ofsize 6 Sqmm 2 core, PVC insulated aluminium solid conductor, served with inner sheathing of PVC tape and overall PVC sheathed in service connections suspended by insulating hangers not more than 1 m apart including replacing 4mm suspension wire including taking down old cable of any descrip[tion complete all as specified and as directed.
34S&F 1100 volts grade heavy duty flat cable ofsize 10 Sqmm 2 core, PVC insulated aluminium solid conductor, served with inner sheathing of PVC tape and overall PVC sheathed in service connections suspended by insulating hangers not more than 1 m apart including replacing 4mm suspension wire including taking down old cable of any descrip[tion complete all as specified and as directed.
35Taking down fan of any type/make and size of AC ceiling fan, carefully from fan hook, dismantling of blades and transporting from any location inside army area to MES E/M store yard and hanging the same carefully in hook and connecting up including provision of cable from ceiling rose or connector to ceiling fan complete all as specified and as directed.
36M&L forGI bracket made out of 40 mm bore medium grade GI Pipe with two sets clamps, with nuts and bolts,two Nos 90 degree bendsall as directed, length of GI Pipe shall not be less than 3.0 metre for fixing of light fittings including taking out old bracket complete all as specified and as directed.
37M&L for plate earthing completewith galvanizedmild steel plate electrode 60 cm x 60 cm x 6 mm thick buried directly in ground vertically (in earth pit not less than2.25 m deep below normal ground level) with the top edge of the earth plate at a depth not less than 1.5 m below normal ground level,the earth electrode surrounded by adequate quantity of charcoal dust and salt to a packed thickness of 15 cm on all sides and incl GI earth lead wire 4 mm dia or 8 SWG bolted (with GI nuts, bolts & check nuts) and earth plate electrodeat one end and connected to main switch board/ DBs etc. at the other, earth strip encased(protected) in and including 15 mm boreGIpipe medium gradewith all fittings from top of electrode to main switch board/ DBs etc fixed with and including 25 x 6mm flat iron clamps, bolts, nuts and washer and also including providing watering pipe 20mm bore GI pipe medium grade from bottom of earth pit to top of electrode complete with earth pit in PCC 1:2:4 type B-2 using 12 mm graded crushed stone aggregate, RCC cover, funnel, wire mesh including necessary excavation and earth work complete all as specified and shown in electrical plate No 3 of SSR Pt-Iincluding dismantling of old earthing complete all as specified and directed.
Disclaimer :
We takes all possible care for accurate & authentic tender information, however Users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender.
Tell us about your Product / Services,
We will Find Tenders for you

Copyright © 2024 · All Rights Reserved. Terms of Usage | Privacy Policy

For Tender Information Services Visit : TenderDetail