| 1 | Pavement |
| 2 | Scarifying the existing bituminous road surface to a depth of 150 mm and disposal of scarified material with a lift upto 3 m and lead upto 1000 m as per Technical Specification Clause 301.4. |
| 3 | WBM Grading 3Providing, laying, spreading and compacting stone aggregates of specific sizes to water bound macadam specification including spreading in uniform thickness, hand packing, rolling with smooth wheel roller 80-100 kN in stages to proper grade and camber, applying and brooming, stone screening to fill-up the interstices of coarse aggregate, watering and compacting to the required density Grading 3 as per Technical Specification Clause 405.(A)By Manual Means |
| 4 | Cell Filled ConcreteConstruction of plastic cell filled cement concrete pavement, thickness as per design, over a prepared sub base, with 53 grade Ordinary Portland Cement(OPC) or any other type as per Clause 1501.2.4 M30 (Grade), coarse and fine aggregates conforming to IS : 2386, maximum in a concrete mixer of not less than 0.2 cum capacityand appropriate weigh batcher using approved mix design (As per IRC:44-2008, laid in approved fixed side formwork (steel channel, wedges, steel plates including levelling the formwork as per drawing), spreading the concrete with shovels, rakes, compacted using needle, screed and plate vibrators and finished in continuous operation, curing of concrete slabs for 14- days, curing compound (where specified) and water finishing to lines and grade as per drawing and Technical Specification of Cell filled Concrete Pavement Published by NRRDA |
| 5 | Construction of subgrade and earthen shoulders with approved material obtained from borrow pits with all lifts and leads,transporting to site, spreading, grading to required slope and compacted to meet requirement of Table 300.2 with lead upto 1000m as per TechnicalSpecification Clause 303.1. |
| 6 | Unlined Drain |
| 7 | (i)Surface Drains in SoilConstruction of unlined surface drains of average cross-sectional area 0.40 sqm in soil to specified lines, grades, levels and dimensions. Excavated material to be used in embankment with a lift upto 3m and lead of 50 m (average lead 25 m) as per Technical Specification Clause 307.(A)Manual Means |
| 8 | (ii)Surface Drains in Ordinary RockConstruction of unlined surface drain of average cross-sectional area 0.4 sqm in ordinary rock to specified lines, grades, levels and dimensions as per approved design and Technical Specification Clause 307. Excavated material to be used in embankment at site.(A)Manual Means |
| 9 | Lined Drain |
| 10 | Earthwork in excavation for structures as per drawing and technical specifications Clause 305.1 including setting out, construction of shoring and bracing, removal of stumps and other deleterious material and disposal upto a lead of 50 m, dressing of sides and bottom and backfilling in trenches with excavated suitable material.I.Ordinary soil(i)Upto 3 m depth |
| 11 | Providing concrete for plain/reinforced concrete in open foundations complete as per drawings and technical specifications Clause 802, 803, 1202 & 1203I.P.C.C grade M 10(i)Nominal mix 1:3:6 |
| 12 | II.P.C.C grade M 15(i)Nominal mix (1:2.5:5) |
| 13 | iv)Pointing with cement mortar 1:3Pointing with cement mortar (1:3) on brickwork as per drawing and technical specification Clauses 613.3 and 1204 |
| 14 | Retaining Wall/Guard Walls |
| 15 | Earthwork in excavation for structures as per drawing and technical specifications Clause 305.1 including setting out, construction of shoring and bracing, removal of stumps and other deleterious material and disposal upto a lead of 50 m, dressing of sides and bottom and backfilling in trenches with excavated suitable material. |
| 16 | Plain cement concrete M 10 gradei)Nominal mix 1:3:6 |
| 17 | Stone masonry in cement mortar 1:5Stone masonry in cement mortar for substructure complete as per drawing & technical specification Clauses 702, 704, 1202 and 1204III)Random rubble masonryiii)In cement mortar (1:5) |
| 18 | Pointing with cement mortar (1:3) on brickwork as per drawing and technical specification Clauses 613.3 and 1204 |
| 19 | Providing P.C.C. M 20 architectural coping on top of retaining wall/breast wallProviding PCC M-20 architectural coping on the top of wing wall, return wall etc. complete as per drawing and technical specification Clauses 615, 710 and 1204.3.11 |
| 20 | Filter material behind retaining wall / breast wall as per Specification 1204.3.8 in a width of 600 mmProviding and laying filter media with granular crushed aggregates as per specification to a thickness of not less than 600 mm with smaller size towards the soil and bigger size towards the wall and providing over the entire surface behind abutment, wing wall, return wall to the full height, compacted to firm condition complete as per drawing and technical specification Clause 1204.3.8 |
| 21 | Back filling behind retaining wall/breast wallBackfilling behind abutment, wing wall and return wall complete as per drawings & technical specification Clause 1204.3.8 |
| 22 | Providing weep holes in brick masonry/stone masonry, plain/reinforced concrete abutment, wing wall, return wall with 100 mm dia AC pipe extending through the full width of the structures with slope of 1(V):20(H) towards drawing face complete as per drawing and technical specification Clauses 614, 709, 1204.3.7 |
| 23 | RCC Railings |
| 24 | Earthwork in excavation for structures as per drawing and technical specifications Clause 305.1 including setting out, construction of shoring and bracing, removal of stumps and other deleterious material and disposal upto a lead of 50 m, dressing of sides and bottom and backfilling in trenches with excavated suitable material. |
| 25 | Plain cement concrete M 10 gradei)Nominal mix 1:3:6 |
| 26 | Construction of R.C.C. railing of M 25 grade in cast-in-situ with 20 mm nominal size aggregate, true to line and grade, tolerance of vertical railing post not to exceed 1 in 500, centre-to-centre spacing between vertical posts not to exceed 2000 mm as per drawing and technical specifications Clauses 800, 900 and 1208.3 |
| 27 | Single Opening Hume Pipe Culvert |
| 28 | Earthwork in excavation for foundation of structures upto 3 m depth as per drawing and technical specification Clause 1104 including setting out, construction of shoring and bracing, removal of stumps and other deleterious matter, dressing of sides and bottom and backfilling with approved material. |
| 29 | Bedding for Pipe(i)Type A (Concrete Cradle) BeddingLaying concrete cradle bedding with M15 Grade Cement Concrete as per Clause 1105 (i) |
| 30 | Providing and Laying Reinforced Cement Concrete Pipe NP3 as per design in Single RowProviding and laying reinforced cement concrete pipe NP3 for culverts on first class bedding of granular material in single row including fixing collar with cement mortar 1:2 but excluding excavation, protection works, backfilling, concrete and masonry works in head walls and parapets Clause 1106.(A) 1200 mm dia |
| 31 | Plain Cement Concrete M10 (1:3:6 nominal mix) in levelling course below open foundation of Head walls as per drawings & Technical Specification Clause 1109 |
| 32 | Plain/reinforced cement concrete in substructure complete as per drawings and technical specification Clauses 802, 804, 805, 806, 807, 1202 and 1204For height upto 5 mI.P.C.C grade M 15(i)Nominal mix (1:2.5:5) |
| 33 | Stone Masonry Work in cement mortar in foundation of Head walls complete as per drawing and technical specification Clause 1109(A) In 1:4 cement mortar |
| 34 | Backfilling in Foundation Trenches as per drawing and technical specification Clause 1108 |
| 35 | Providing PCC M20 Architectural Coping on the top of wing wall, return wall etc. complete as per drawing and technical specification Clause 615 |
| 36 | Stone masonry in cement mortar 1:5Stone masonry in cement mortar for substructure complete as per drawing & technical specification Clauses 702, 704, 1202 and 1204III)Random rubble masonry |
| 37 | Pointing with cement mortar (1:3) on brickwork as per drawing and technical specification Clauses 613.3 and 1204 |
| 38 | Filter material behind retaining wall / breast wall as per Specification 1204.3.8 in a width of 600 mmProviding and laying filter media with granular crushed aggregates as per specification to a thickness of not less than 600 mm with smaller size towards the soil and bigger size towards the wall and providing over the entire surface behind abutment, wing wall, return wall to the full height, compacted to firm condition complete as per drawing and technical specification Clause 1204.3.8 |
| 39 | Catch Pit Repair |
| 40 | Plain Cement Concrete M10 (1:3:6 nominal mix) in levelling course below open foundation of Head walls as per drawings & Technical Specification Clause 1109 |
| 41 | Plain/reinforced cement concrete in substructure complete as per drawings and technical specification Clauses 802, 804, 805, 806, 807, 1202 and 1204I.P.C.C grade M 15(i)Nominal mix (1:2.5:5) |
| 42 | Pointing with cement mortar (1:3) on brickwork as per drawing and technical specification Clauses 613.3 and 1204 |
| 43 | RCC Bridge |
| 44 | Earthwork in excavation for structures as per drawing and technical specifications Clause 305.1 including setting out, construction of shoring and bracing, removal of stumps and other deleterious material and disposal upto a lead of 50 m, dressing of sides and bottom and backfilling in trenches with excavated suitable material.I.Ordinary soil(i)Upto 3 m depth |
| 45 | (ii)3 m to 6 m depth |
| 46 | Providing concrete for plain/reinforced concrete in open foundations complete as per drawings and technical specifications Clause 802, 803, 1202 & 1203I.P.C.C grade M 10(i)Nominal mix 1:3:6 |
| 47 | Providing concrete for plain/reinforced concrete in open foundations complete as per drawings and technical specifications Clause 802, 803, 1202 & 1203II.P.C.C grade M 15(i)Nominal mix (1:2.5:5) |
| 48 | Supplying, fitting and placing HYSD bar reinforcement in foundation complete as per drawings and technical specifications Clauses 1000 and 1202 |
| 49 | Plain/reinforced cement concrete in substructure complete as per drawings and technical specification Clauses 802, 804, 805, 806, 807, 1202 and 1204(i)P.C.C grade M 15(i)Nominal mix (1:2.5:5) |
| 50 | Plain/reinforced cement concrete in substructure complete as per drawings and technical specification Clauses 802, 804, 805, 806, 807, 1202 and 1204(ii) R.C.C grade M 20 |
| 51 | Supplying, fitting and placing HYSD bar reinforcement (Fe 415) in substructure complete as per drawings and technical specification Clauses 1002, 1005, 1010 & 1202 |
| 52 | Providing weep holes in brick masonry/stone masonry, plain/reinforced concrete abutment, wing wall, return wall with 100 mm dia AC pipe extending through the full width of the structures with slope of 1(V):20(H) towards drawing face complete as per drawing and technical specification Clauses 614, 709, 1204.3.7 |
| 53 | Backfilling behind abutment, wing wall and return wall complete as per drawings & technical specification Clause 1204.3.8II)Sandy material |
| 54 | Providing and laying filter media with granular crushed aggregates as per specification to a thickness of not less than 600 mm with smaller size towards the soil and bigger size towards the wall and providing over the entire surface behind abutment, wing wall, return wall to the full height, compacted to firm condition complete as per drawing and technical specification Clause 1204.3.8 |
| 55 | Providing and laying reinforced cement concrete in superstructure as per drawing and technical specifications Clauses 800, 1205.4 and 1205.5II.R.C.C M 25 |
| 56 | Supplying, fitting, and placing HYSD bar reinforcement in superstructure complete as per drawing and technical specifications Clauses 1002, 1010 and 1202 |
| 57 | Providing and laying cement concrete wearing course M 30 grade including reinforcement complete as per drawing and technical specifications Clauses 800 and 1206.3 |
| 58 | Construction of R.C.C. railing of M 25 grade in cast-in-situ with 20 mm nominal size aggregate, true to line and grade, tolerance of vertical railing post not to exceed 1 in 500, centre-to-centre spacing between vertical posts not to exceed 2000 mm as per drawing and technical specifications Clauses 800, 900 and 1208.3 |
| 59 | P.C.C. M 15 ordinary grade (1:2.5:5) levelling course below approach slab complete as per drawing and technical specifications Clauses 800 and 1211(i)Nominal mix (1:2.5:5) |
| 60 | Reinforced Cement Concrete M 25 grade approach slab including reinforcement and formwork complete as per drawing and technical specifications Clauses 800 and 1211 |
| 61 | Providing and laying of an elastomeric slab seal expansion joint complete as per approved drawing and approved specifications to be installed by manufacturer/supplier or their authorised representative ensuring compliance to the manufacturer’s instructions for installation and as per technical specifications Clause 1207.2.5 |
| 62 | Kilometre Stones, 200m StonesReinforced cement concrete M15 grade kilometre stone/local stone of standard design as per IRC:8 fixing in position including painting and printing, etc as per drawing and Technical Specification Clause 1703 |
| 63 | (i)Ordinary Kilometer Stone (Precast) |
| 64 | (ii)200 m stone (precast) |
| 65 | Sign Boards, Traffic Signages etc.Traffic SignsB.Semi Reflective Traffic SignsProviding and fixing of semi reflective cautionary, mandatory and informatory sign board as per IRC:67 made of 1.5 mm thick MS Sheet duly stove white colour in front and gray colour on back with red reflective border of 65 mm width and required letters and figures with reflective tape engineering grade as per Clause 1701.3.9 of MORD for Rural Roads of required shade and colour supported and welded on 47mm x 47 mm x 12 SWG sheet tube firmly fixed to the ground by mean of properly designed foundations with M-15 grade cement concrete 450x450x600 mm, 600 mm below ground level as per approved drawing Clause 1701.2.2 |
| 66 | i)900 mm equilateral triangle(i) Left Hand Curve |
| 67 | i)900 mm equilateral triangle(ii) Right Hand Curve |
| 68 | i)900 mm equilateral triangle(iii) Right Hairpin Bend |
| 69 | i)900 mm equilateral triangle(iv) Left Hairpin Bend |
| 70 | i)900 mm equilateral triangle(v) Right Reverse Bend |
| 71 | i)900 mm equilateral triangle(vi) Left Reverse Bend |
| 72 | i)900 mm equilateral triangle(vii) Series of Bends |
| 73 | i)900 mm equilateral triangle(viii) Y intersection Right |
| 74 | i)900 mm equilateral triangle(ix) Y Intersection Left |
| 75 | i)900 mm equilateral triangle(x) Major road Ahead |
| 76 | i)900 mm equilateral triangle(xi) Pedestrian |
| 77 | 600 mm circular(i) Overtaking Prohibited |
| 78 | 600 mm circular(ii) Maximum Speed Limit |
| 79 | Direction and Place Identification signs upto 0.9 sqm size boardA.Retro-reflectorised Traffic Signs(i)Providing and erecting direction and place identification retro-reflectorised sign as per IRC:67 made of encapsulated lens type reflective sheeting vide Clause 1701.2.3, fixed over aluminium sheeting, 2 mm thick with area not exceeding 0.9 sqm supported on a mild steel single angle iron post 75 x 75 x 6 mm firmly fixed to the ground by means of properly designed foundation with M-15 grade cement concrete 450 x 450 x 600 mm, 600 mm below ground level as per approved drawing and Technical Specification Clause 1701 |
| 80 | Painting lines, dashes, arrows, etc. on roads in two coats on new work with ready mixed road marking paint conforming to IS:164 on bituminous/ concrete surface, including cleaning the surface of all dirt, dust and other foreign matter, demarcation at site and traffic control as per drawing and Technical Specification Clause 1702 |
| 81 | (i) Centre Line |
| 82 | (ii) Edge Line |
| 83 | Providing and Fixing \"Logo\" of PMGSY ProjectProviding and fixing of typical PMGSY informatory sign board with Logo as per MORD specifications and drawing. Three MS Plates of 1.6 mm thick, top and middle plate duly welded with MS flat iron 25mm x 5m size on back on edges. The lower plate will be welded with MS angle iron frame of 25mm x 25mm x 5mm. The angle iron frame of the lower most plate and flat iron frame of middle plate will be welded to 2 nos. 75mm x 75 mm of 12 SWG sheet tubes posts duly embedded in cement concrete M-15 grade blocks of 450mm x 450mm x 600mm, 600mm below ground level. The top most diamond plate will be welded to middle plate by 47mm x 47mm of 12 SWG steel plate tube. All M.S. will be stove enameled on both sides. Lettering and printing arrows, border etc. will be painted with ready mixed synthetic enamel paint of superior quality in required shade and colour. All sections of framed posts and steel tube will be painted with primer and two coats of epoxy paint as per drawing Clause 1701 and Annexure 1700.1 |
| 84 | (i) Citizen Information Board |
| 85 | (ii) Title information Board |
| 86 | (iii) Logo Board at Starting Point |
| 87 | (iv) Logo Board at every 2 Km |
| 88 | Providing and fixing \" MAINTENANCE INFORMATION BOARD\"Providing and fixing of typical PMGSY informatory sign board with Logo as per MORD specifications and drawing. One Single MS Plates of 1.6 mm thick welded with MS angle iron frame of 25mm x 25mm x 5mm will be welded to 2 nos. 75mm x 75 mm of 12 SWG sheet tubes posts duly embedded in cement concrete M-15 grade blocks of 450mm x 450mm x 600mm, 600mm below ground leve. All M.S. will be stove enameled on both sides. Lettering and printing arrows, border etc. will be painted with ready mixed synthetic enamel paint of superior quality in required shade and colour. All sections of framed posts and steel tube will be painted with primer and two coats of epoxy paint as per drawing Clause 1701 and Annexure 1700.1 |
| 89 | Rumble StripsProvision of 15 nos. rumble strips covered with premix bituminous carpet, 15-20 mm high at centre, 250 mm wide placed at 1 m centre-to-centre at approved locations to control speed, marked with white strips of road marking paint. |
| 90 | Good and Service Tax (18%) |
| 91 | Five Years Maintenance |
| 92 | Maintenance for 1st Year |
| 93 | Maintenance for 2nd Year |
| 94 | Maintenance for 3rd Year |
| 95 | Maintenance for 4th Year |
| 96 | Maintenance for 5th Year |
| 97 | Maintenance for 6th Year Renewal Plan |