Military Engineer Services-MES has published Tender For Repair And Maintenance Of Dosing Plants, Solar Water Systems, Washing Machine, Dg Sets, Amf Panel, Water Supply Installations And Other Connected Works Under Age E/M-Ii Of Ge (N) Mamun. Submission Date for this Tender is 28-08-2023. Diesel Generators Tenders in mamun Punjab. Bidders can get complete Tender details and download the document.




Tender Notice

38905197
Corrigendum : Tender For Repair And Maintenance Of Dosing Plants, Solar Water Systems, Washing Machine, Dg Sets, Amf Panel, Water Supply Installations And Other Connected Works Under Age E/M-Ii Of Ge (N) Mamun
Open Tender
Indian
Punjab
mamun
28-08-2023

Tender Details

Repair And Maintenance Of Dosing Plants, Solar Water Systems, Washing Machine, Dg Sets, Amf Panel, Water Supply Installations And Other Connected Works Under Age E/M-Ii Of Ge (N) Mamun

Corrigendum Details

Sr No CorrigendumDate Corrignedum CorrigendumType NewSubmissionDate
1 21-Aug-2023 Bid Auto Extn Corrigendum Bid Auto Extn Corrigendum 28-08-2023

Key Value

Document Fees
INR 500 /-
EMD
INR 60000.0 /-
Tender Value
INR 30 Lakhs /-

BOQ Items

Name of Work: REPAIR AND MAINTENANCE OF DOSING PLANTS, SOLAR WATER SYSTEMS, WASHING MACHINE, DG SETS, AMF PANEL, WATER SUPPLY INSTALLATIONS AND OTHER CONNECTED WORKSUNDER AGE E/M-II OF GE (N) MAMUN
Sl. No. Item Description
1Disconnectingdosingplant of any model, any capacity alongwith components, dismantling and segregation of all parts, repair /replacement of defective parts, cleaning, washing, re-assembling the parts, connecting in position and testing complete all as specified and directed. Note :- a. Spares will be measured and paid under item No 1.01 to 1.12 b. All the repairs required and pertain to dosing plant shall be carried out & the contractor shall ensureto depute his supervisor at the concern installations for repair and smooth functioning of the same. The delay in repair if noticed not carried out on the same day, the recovery shall be made @ Rs 500/- per day fromcontractor"s RAR/bill till completion of the job. c. Repair work of dosing plant is of urgent nature because unchlorinated water cannotbe Supplied to the troops. This point shall be kept in mind while quoting the rates, nothing extra on any account shall be admissible.
2Supply only suction valve assembly complete of dosing plant(liquid end) (as per sample)
3Supply only discharge valveassembly complete
4Supply only diaphragm for dosing plant(liquid end) (as per sample)
5Supply only foot valve assembly for dosing plant (liquid end) (as per sample)
6Supply only NRV assembly for dosing plant (as per sample)
7Supply only head for dosing plant (liquid end) (as per sample)
8Supply only tubing for dosing plant including all accessories (liquid end) (as per sample)
9Supply only Injector valve including fitting (as per sample)
10Supply only PCB for dosing pump (as per sample)
11Supply only impeller of agitator blade made of PVC all (as per sample).
12Supply only extended agitator shaft of non-corrosive material all (as per sample).
13Supply only complete Set of "O" rings
14Dismantelling of old burnt motor of dosing plant 960 RPM, rewinding with super enamelled copper wire as per existing with replacing all unserviceable parts of motor for making it as serviceable including ball bearing etc complete all as specified and directed. NOTE:-Spare part shall be included in quated rate.
15Repair to centrifugal horizontal boosterpump up to 5 stage, 3 to 5.5 HP by dismentling of all parts, repair/replacement of defective/worn out parts, necessary machine work, welding work, replacement of nuts, bolts & washers, gland packing including greasing etc. Fixing new spare parts, re-assembling the pump and fixing in position including testing at site complete all as directed Note:New spare parts shall be measured and paid under item No 3.01 to 3.08 as supply only.
16Supply only Impeller Gun Metal (as per sample) for horizontal booster pump .
17Supply only Pump Shaft Stainless Steel (as per sample) for horizental booster pump.
18Supply only Impeller casing cast iron (as per sample) for horizental booster pump.
19Supply only Discharge/Suction case housing of cast iron (as per sample).
20Supply only Intermediate casing bush Gun Metal (as per sample) for horizental booster pump.
21Supply only Gland nut/Cup Gun Metal (as per sample).
22Supply only Ball bearing of pump 5.5 HP electric motor (as per sample)
23Supply only Pump motor coupling cast iron with rubber (as per sample).
24S&F control panel MU-G6 consist of contactor, relay, on off switch, SPP auto/manual mode, terminal plate, volt and Amp meter complete all as specified and directed. Make :- L&T/ABB/BCH
25S&F GI pipe 20 mm bore dia medium grade including all heavy duty fittings such as union,elbow,socket & nipple including taking down existing pipe with fittings, removalcomplete all as specified and directed. Make :- Prakash Surya/Jindal/Oswal
26S & F in repair Gun Metal Gate Valve 20 mm bore dia, heavy duty ISI marked screwed both ends for fixing pipe complete all as specified and directed. Make :- Zoloto/L&T/Kirloskar
27Supply & installation in replacement of unserviceable dosing plant motor, single phase, 90 watts, 1440 RPM, 230 Volts, 50 cycles, 02 Amps having speed controller to reduce speed upto 800 RPM, mounted on tank complete all as specified and directed.
28M&L for rewinding of 3 phase electric motor of 3 to 5.5 HP Booster pump with super enamelled copper winding wire as per existing including impregnated paper, sleevs, lathorised fibre glass, varnish and tape, etc complete all as specified and directed.
29Supply and filling in dozing plant calcium based, high strength chlorination chemical for water disinfectant in granular form in factory sealed HDPE container (40 to 50 Kg each), chlorine concentration level 65-70% complete all as specified and directed.
30Supply & installation in replacement of old dosing tank capacity 100 Ltrs MOC:PE/FRP.Lid containing port hole for pouring chlorination chemical and water when necessary. Provision for mounting of motor at proper angle provision for mounting dosing pump on lid, level gauge, Cat part No 042009C make :- DECLIBAC/AQUAFIT/PURICHLOR.
31M&L for Repair of solar water heater capacity upto 500 LPDafter carefully opening of different tubes, electricalconnectionand unscrewing of nuts and bolt from foundation, refixing the same after cleaning and serviceable complete all as specified and directed.
32M&L for3 layer PP-R polypropylene random copolymer concealed pipe 25mm bore SDR 7.4 (PN-1.6) UV stablised and antimicorobial fusion welded having thermal stability for hot and cold water suppy. All PP-R plain & brass threaded polypropylene random fittings shall be laid in trenches including taking out and removal complete all as specified and directed.
33All as per item 12 but size of pipe 20mm bore.
34Supply and replacement Evacuated heat tubeof any size by taking out the broken tube complete.
35Supply and replacement PP-R gate valve brass inserted 25mm bore complete all as specified and directed.
36All as per item 15 but size of pipe 20mm bore.
37Excavationin trenchesn.exc 1.5mtr wideand n.exc 1.5mtr deep in soft/loose soil and gettingoutfor laying of pipescomplete all as specified and directed.
38Returning, filling in trenches including spreading, levelling, watering and well ramming in layers n.exc 25cm thick complete all as specified and directed.
39Removal of surplus soilto a distance n.exc 50m and depositing where directed at a level n.exc 1.5m above the starting point complete all as specified and directed.
40Supply and replacement two layered, ISI marked Rotational moulded polyethylene water storage tank (cylinderical vertical with closed top) hoisted and fixed in position of capacity500 litre including taking down unserviceable water storage tank and removal complete all as specified and directed.
41S & Fixed in repair tank nipple (as per sample)after makingproper hole in inlet and outlet portion complete all as specified and directed.
42S & Fixed in repair Floatvalvewith iron rod andball20mm dia .
43Supply and replacement of heating element 3000 watt for solar water heater (as per sample) complete all as specified and directed.
44Supply and replacement of thermostat suitable for solar water heater (as per sample) complete all as specified and directed.
45M&L for Repair to washing machine Hydro extractor of cap 30 Kgs , 3 phase, 415volts, 50Hz , AC including replacement of defective componant/spares etc, servicing, greasing etc complete and testing of the machine complete all as specified and directed. Note :- (a) Defective major components/spares shall be measured as supply only under item 25.01 to 25.04. (b) Charges for attending break down ofwashingMachine Hydro extractor, servicing bymachenic for fault finding, attending repairsas and when required such as "No start" condition of washing machine, repairing, starting of washing machine, setting up the alignment/required paramenters of all minor parts repairs such as fan belt for motor Micro processor based control panel etc as required in ground, to the satisfaction of Engineer in Charge shall included in the quoted rates, nothing extra shall be admissible on this account.
46Supply only IBLAR bearingfor 30 Kgs washing machine (as per sample)
47Supply only single phase preventor suitable for 30 kgs washing machine as persample
48Supply only LS contactor 3 pole 220 volts 32 Amps suitable for 30 kgs Dryer (as per sample)
49Supply only Relay 2.5 Amps to 6 Amps for Dryer Machine Motor(as per sample)
50M&L for Repair to washing machine Hydro extractor and Tumblerdrying machine of cap 25 Kgs , 3 phase, 415volts, 50Hz , AC including replacement of defective componant/spares etc, servicing, greasingand gland dori for motor complete and testing of the machine complete all as specified and directed. Note :- (a) Defective major components/spares shall be measured as supply only under item 26.01 to 26.03 (b) Charges for attending break down ofwashingMachine Hydro extractor, servicing bymachenic for fault finding, attending repairsas and when required such as "No start" condition of washing machine, repairing, starting of washing machine, setting up the alignment/required paramenters of all minor parts repairs such as fan belt for motor Micro processor based control panel etc as required in ground, to the satisfaction of Engineer in Charge shall included in the quoted rates, nothing extra shall be admissible on this account.
51Supply only LS contactor 3 pole 220 volts 0 to 18 Amps suitable for 25 Kgs washing machine (as per sample)
52Supply only IBLARbearingfor 25 kgs washing machine (as per sample)
53Supply only relay 2.5 Amps to 8 Amps for Dryer Machine Motor(as per sample)
54M&L for Repair/Replacementof chemical dosing pump (for injection for disinfection of water treatment ) injection of capacity @ 15 LPH(type MAGDO/MD/20/40) having 15 LPH at 10 kg per cm2 working pressure solenoid driven, electrically control 220 volts, maximum current 3.3 Amps, maximum power 70 watt with IP 65 protection and "F" class insulation, with standard fittings, with stoke length suitable from 0-100%,stock frequency suitable from 0-to 100% minimum, including all accessories such as footvalve, line injection valve, suction valve, delivery valve and PE tubing consistencey in performancecomplete all as specified and directed. Make : JESCO/VERIMA/ION EXCHANGE
55Maintenance and servicing of DG sets (any make, type and capacity) including replacement of defective/burn out parts by new spares such as replacement of oil, oil filter, air filter, fan belt, hosepipe, checking turbocharger, oil leakage, tightening of mounting screws & nuts, gaskets, V-belts, cleaning of oil sump, refilling and top up of oil, coolant, wornout clamps, checking inlet & Exhaust manifold cap, screws,fan hub & water pump, complete control wiring inlcuding electrical connections,On/Off switch, nut and bolts, cleaning of alternator with vaccum cleaner, greassing of bearing, cleaning of radiator fins using blower, inside tank with solution (caustic soda with water), trial & testing etc complete to the entire satisfaction of Engr-in-charge, for the following capacity DG sets :- Note :- (1) Supply only of spares/parts required for maintenance (except measured and paid seperately under respective item i.e 30 to 34.02 of BOQ ) shall deemed to be included in quoted under this item, nothing extra shall be admissible on this account. (2) All the checks of DG set (as per menufacturer"s instructions) shall be got carried out by the contractor to the satisfaction of Engineer in Charge. Contractor"s quoted rates shall deemed to be included this fact into account and nothing extra shall be admissible on this account. (3) The DG set shall be tested on load (30 minuts) as per rated capacity for the entire satisfaction of Engineer- in- Charge.
56a) DG set of 50 to 63 KVA
57b) DG set of75 to 160 KVA
58Supply only diesel filter (Primary and baby) element with O rings suitable for following capacitiesof DG sets
59a) DG set of 50 to 63 KVA
60b) DG set of75 to 160 KVA
61Supply only Engine oil filter element/ bye pass engine oil filter elementwith O ring suitable for following capacities of DG sets.
62a) DG set of 50 to 63 KVA
63b) DG set of75 to 160 KVA
64Supply only air filter element suitable for suitable capacities of DG sets
65a) DG set of 50 to 63 KVA
66b) DG set of75 to 160 KVA
67Supply only fan belt suitable for followingcapacities of DG sets
68a) DG set of 50 to 63 KVA
69b) DG set of75 to 160 KVA
70Supply only rubber hose pipe of any size set with clampsuitable for followingcapacities of DG sets
71a) DG set of 50 to 63 KVA
72b) DG set of75 to 160 KVA
73Supply and fixing copper cable multi stranded (set of two- red & black cable) suitable for 12/24 volts battery, replacing the same with ofexisting size and equal length complete, fixed with new brass terminals at both ends including taking down of oldfrom the existing battery as directed complete.
74Supply and replacement of engine oil (filling in /toping up of engine oil) multi grade 20-W-40 in enginecomplete all as specified and directed. Make :- Indian Oil/Hindustan Petrolium/Castrol
75Dismantling of defective alternator, any capacity from the existing foundation and from Engine after removing all electrical connections, transporting to approved/ authorised/ directed workshop, opening and taking out burnt winding, cleaning the stator assembly rewinding with super enameled copper wire as per existing gauge, applying insulating varnishing of ‘F’ class, baking in oven re-assembling the alternator, transporting back tosite, re-installing in same position, carrying out alignment of complete DG set, making/ connecting up all electrical connections, testing and commissioning complete all as specified and directed. Note: - (a) Contractor"s quoted rates shall be deemed to be inclusive of all minor accessories i.e sleeves, nut bolt, washers etc, making good the disturbed surfaces. (b) The DG set shall be tested on load as per rated capacity for the entire satisfaction of Engineer-in-Charge.
76S & F in repairs push button forself starter /or Key arrangement for starting DG set as per sample complete all as specifed and directed.
77S & F in repair door hinges for canopy of any capacityofDGset doorincluding nut, bolt, drilling of hole, welding as per directed complete all as specifed and directed.
78Supply and fixing in repair battery terminals brass, suitable for 95 AH to 180 AH battery( as per sample) complete all as specifed and directed.
79Dismantling the radiator assembly from the DG set of 50 KVA to 75 KVAcapacitycarefully for necessary repair, cleaning properly, soldering cooling tube if found weak/leakage, replacement of nuts, bolts, rubber mounting bushes etc, refixing at the same position including testing complete all as specifed and directed.
80S & F in replacement connecting and commissioinglead acid battery 12 volts 180 AH complete all as specifed and directed. Make-Amaron/Exide/Tata Green
81S & F in repairs/replacementconnecting and commissioinglead acid battery 12 volts 130 AH complete all as specifed and directed. Make-Amaron/Exide/Tata Green
82M&L for providing new AVR unit suitable for 50 KVA to 160 KVA DG Setincluding taking down of old AVR unit, complete all as specified and as directed.
83Dismantling the defective self starter assembly of 12/24 volts, necessary repair with replacement of defective spares such as, carbon brushes with spring, bearing, bushes, defective burnt wiring and soldering after repair, re-assembling and refixing at site including testing complete all as as directed.
84M & L for openingthe cylinder head of the engine and oil sump carefully for replacement of head gasket, piston ring, compression ring, piston, crank shaft including sump gasket complete refixing the headand sump to arrest oil leakage with engine complete with proper alignment and testing the engine on load to achiveve designed parameters all as directed by Engineer-in-Charge of capacity 50 KVA to 160 KVA.
85Supply and filling in coollant (as per manufacturer"s recommonded grade) in engine complete all as specified and directed.
86Supply and replacement of Diesel pipe suitable for existing size of50 KVA to 160 KVADG Set includingboth side hose clamp, etc complete.
87Dismentiling of old LT Panel after carefully disconnectioningLT electrical connections, removal from site andsupply, installation, testing and commissinoning LT panel suitable for working on 3 phase, 4 wire, 415 volts, AC, 50Hz, indoor type, floor mounted, free standing, dust and vermin proof, air ventilation, factory fabricated made out of 2 mm thick CRCA sheet duly powder coated painted, CPRI approved. The Panel shall have front and rear opening, locking arrangement, cable alleys, bus bar chamber and switch gear compartment, hinged door with rubber gasket, cable gland, bottom cable entry holes for incoming and out going cables, earthing terminals, affix danger notice plate, Aluminium bus bar duly covered with heat shrink sleeves colour coaded duly fixed on DMC/SMC insulators, housed in a separate bus bar chamber and control wiring with copper conductor cables of adequate size and length, incoming and outgoing MCCBs shall have extended bus bar links,mounted on MS angle iron frame of suitable size (as per existing) duly painted embaded in PCC 1:2:4 Type B1 (using 20 mm graded crushed stone aggregate ) in foundation as approved complete all as specified and directedcomprising of following :- (a) MCCB 415 V 4 Pole 200 Amps 36 kA with adjustible thermal and adjustible magnetic setting- 01Nos(incommer) (b) MCCB 415 V 3 Pole 160 Amps 36 kA with adjustible thermal and adjustible magnetic setting- 01Nos (Outgoing) (c)MCCB 415 V 3 Pole 63 Amps 36 kA with adjustible thermal and adjustible magnetic setting- 01Nos (Outgoing) (d)MCB 63 Amps, FP,10 KA, 415 volts, 50Hz-1 Nos (Outgoing) (e)Fully Automatic Star Delta Starter MU-G40 FASD (With Wideband Coil). Make& L&T Cat Pt No CS96008LOTO- 01Nos (f) On-load change over switch 200 Amps, 4Pole, 415 V, 50Hz front handle operated type -01 No Make: L&tABB/Havells (g) DigitalAmmeter, with CTs & ASS-01 set (h) Digital voltmeter, with VSS-01 set (j)LED phase indication lamps RYB-01 set (k)Motor protection Relay (protection against over load,under voltage,phase loss,phase unbalance,phase asymetery (l) CTs 3 Nos of current ratio 150/5A - Set of 3 (m) Aluminium bus bar TPN 200 Amps rating -01 set
88All as per item 48but comprising of following :- (a)MCCB 415 V 4 Pole 200 Amps 36 kA with adjustible thermal and adjustible magnetic setting- 01Nos(incommer) (b)MCCB 415 V 3 Pole 160 Amps 36 kA with adjustible thermal and adjustible magnetic setting- 01Nos (Outgoing) (c)MCCB 415 V 3 Pole 63 Amps 36 kA with adjustible thermal and adjustible magnetic setting- 01Nos (Outgoing) (d)MCB 63 Amps, FP,10 KA, 415 volts, 50Hz-1 Nos (Outgoing) (e)Fully Automatic Star Delta Starter MU-G50 FASD (With Wideband Coil). Make& L&T Cat Pt No CS96009COJO- 01Nos (f)On-load change over switch 200 Amps, 4Pole, 415 V, 50Hz front handle operated type -01 No Make :- L&T/ABB/Havells (g)Digital Ammeter, with CTs & ASS-01 set (h)Digital voltmeter, with VSS-01 set (j) LED phase indication lamps RYB-01 set (k) Motor protection Relay (protection against over load,under voltage,phase loss,phase unbalance,phase asymetery (l) CTs 3 Nos of current ratio 150/5A - Set of 3 (m) Aluminium bus bar TPN 300 Amps rating
89M & L for Earthing complete with GI earth plate, electrode 600x600x6 mm thick burried directly in ground (earth pit not less than 2.25m deep below normal ground level) filled with common salt and charcoal and connected to GI earth strip 25x4 mm thick by means of GI nuts, bolts & washers as shown in electrical plate No. 5 of SSR Part-I and Connected to earthing test point all as specified and including necessary PCC earth pit chamber of 1:3:6 and chamber cover of 50mm thick PCC 1:2:4 with 6mm dia mild steel reinforcement of 10 cm c/c spacing both ways in lieu of CI cover, watering arrangement shall be made with GI pipe light grade of 20mm dia including funnel, protection to earth lead with GI pipe light grade 40 mm dia upto 7.5 from the earth plate electrode, including necessary excavation & earth work (in any strata) and PCC chamber including demolish existing earth pit taking out old materials complete all as specified and directed
90S & F in repairs Galvanised iron strip 25x4 mm buried in ground/fixed on walls/ceilings by using suitable size GI saddles etc complete all as specified and directed.
91S & F in repairs phase Indicator Lamps (LED type) showing R,Y, B phase (as per sample) complete all as specified and directed .
92S & F in repairs Digital Amp Meter 0 - 500 Amp, size 96x96 mm square type with selector switch(as per sample) complete all as specified and directed
93S & F in repairs Digital Volt meter 0 - 400V, size 96 x 96 mm square type with selector switch (as per sample) complete all as specified and directed
94S & F in repairs change over switch 4 pole 415 volts front operate type of capacity 200 Amps (On load open execution) including necessary spreaders/cable lugs/nut, bolt and washers if required complete all as specified and directed Make :- L&T/Havells/Legrand/Indoasian
95S & F in repairs of 3 pole power Contactor AC control 150 Amp capacity complete including fixing arrangement all as direcetd. (Make :- L&T/ABB/Legrand)
96S & F battery charging unit panel mounted automatic operated electronically 12 Volts DC out put and 230 volts incoming AC, as per the existing make and size to accomodate in the space provided in the AMF panel board complete all as specified and directed.
97Dismantling the old and unserviceable DG Set Diesel/oil pressure pipe brass nozzle/brass terminal of existing size and replacing the same with of existing size and equal length of 50 KVA to 160 KVA DG Set includingboth side hose clamp, etc as directed by the Engineer in Charge .
98Supply and fixing heat proof, fire proof/flame proof asbestos rop 12mm dia on engine exhaust pipe including dismentling of worn out asbestos rope and minor welding/tighting in leakage exhaust complete all as directed .
99S & F battery charging unit industrial type floor mounted heavy duty, with steel enclosure, volt meter, Ammeter, Toggle switch, charger ON-OFF switches suitable for charging 2 Nos of lead acid battery 12- 24 V DC (20 Amp) out put type and suitable for 230 volts incoming AC supply all as directed. Make :- ELAK/AMCO/SU-KAM
100M & L in Replacement of old aluminium cable of 3.5 core from DG set to electrical panel with new 70 SqmmXLPE insulated armoured heavy duty electric cable with aluminium conductor 1100 volts through GI pipe light grade suitable size for cable and cutting the floor/kota stones including thimbling both side complete all as specified and directed.
101Supply, installation, commissioning and testing star delta starter suitable for 60 HP ML4F motorrelay range 45 to 75 Amp, including single phase preventor fully automaticin sheet metalenclosuretype AC, 3 phase, 415 volts, 50HZ including taking out old unsv starter complete all as specified and directed. Make: L&T/ABB or equivalant as approved.
102Supply and fixin replacement smart integrated solar street light 20 W including galvanized steel pole (pole lenght not less then 6mtr) in built in Mono Crystalline panel, Lithium Ferro Phospate battery, MPPt Charge Controller and PIR sensor with colour Temperature including necessary fixing arrangement by providingwith necessary nuts, bolts and washers etc complete all as specified and directed
103S & F in replacement of Plates (plain or chequered) channels, squarecutor notched (ordinary and counter sunk) forming holes, without any attachment cut to required shape and size for cable duct or any other description and including painting with two coats of synthetic enamel paint over a coat red oxide primer complete all as specified and directed.
104Charges for attending break down of DG set of 50 to 160 KVA capacity for fault finding including attending repairsas and when required such as No start condition of DG and repairing, starting the DG set till smooth running and setting up the alignment/required paramenters of all major parts such as fan belt, AVR, RPM, sencors, actuators, Engine safety units, batteryy chargers, AMF relays, fuel/oil levels, speed governer, Micro processor based control panel, Injector pumps etc as required in ground as directed.
105M&L in replacement, providing new rectifier diode unit suitable for 50 KVA to 160 KVA DG Set as per sample, size in repairs ie taking down of old rectifier unit, complete all as specified and directed.
106M & L for PVC rounded 3 core 1.5 sqmm copper cable and making necessary connection complete all as specified & directed.
107Supply and fixing electrical insulation rubber mating ISI marked and size 1m x 2m x 6mm thick (conform to sample) complete all as specified and directed.
108S & F in replacement MCCB 4 Pole, current rating 250 Amp, adjustable over load and short circuit with Micro processor release setting, breaking capacity 50 kA at 415V, 50Hz, of incl necessary spreaders/cable lugs/nut, bolt and washers if required all as direcetd.
109All as per item No 72 abvoe but 4 pole 200 A, having breaking capacity 50 kA.
110All as per item No 72 above but 3 pole 160 A, having breaking capacity 36 kA.
111Deduct: Total amount of SCHEDUL "A" SECTION-II (SCH OF CREDIT) Rs 73,379.00 ( to be deducted from Schedule ‘A’ (BOQ) to arrive at the Contract Sum.