Tender For Repairing Of 11 / 0.4Kv 10, 25, 63 & 100 Kvadamage Transformer At Sahupuri Workshop Chandauli Under Ewd Varanasi., chandauli-Uttar Pradesh

Purvanchal Vidyut Vitaran Nigam Limited has published Tender For Repairing Of 11 / 0.4Kv 10, 25, 63 & 100 Kvadamage Transformer At Sahupuri Workshop Chandauli Under Ewd Varanasi.. Submission Date for this Tender is 08-08-2023. Electrical Maintenance Tenders in chandauli Uttar Pradesh. Bidders can get complete Tender details and download the document.




Tender Notice

38900660
Tender For Repairing Of 11 / 0.4Kv 10, 25, 63 & 100 Kvadamage Transformer At Sahupuri Workshop Chandauli Under Ewd Varanasi.
Open Tender
Indian
Uttar Pradesh
chandauli
08-08-2023

Tender Details

Repairing Of 11 / 0.4Kv 10, 25, 63 & 100 Kvadamage Transformer At Sahupuri Workshop Chandauli Under Ewd Varanasi. 1 Handling And Dragging Of Transformer From Stacking Yard To Repairing Hall. 2 10Kva 3 25Kva 4 63Kva 5 100Kva 6 Cutting Of Sealed Transformers Top Cover Plate Smoothly And Uniformally By Gas / Chisel Cutter Or Opening Of Top Cover Plat And Detanking Of Core And Coil Assembly. 7 10Kva 8 25Kva 9 63Kva 10 100Kva 11 Dragging Of The Tank From The Repaired Hall To Yard. & Cleaning Oil And Dust Etc. And Scraping The Rust Etc Andwashing Of Transformer Tank With Caustic Soda & Water, Caustic Soda Shall Be Provided By Contractor 12 10Kva 13 25Kva 14 63Kva 15 100Kva 16 Painting Of Inner Side Of Transformer Tank And Channels With Heat Proof Zinc Chromate Paint Of Good Quality ( Berger, Nerolac, Jenson & Nicholson Etc ) Shall Be 17 10Kva 18 25Kva 19 63Kva 20 100Kva 21 Dragging Out Empty Tank From Yard To Repairing Hall. 22 10Kva 23 25Kva 24 63Kva 25 100Kva 26 Dismantling Core And Coil Assembly And Cleaning Of Dust And Dirt From The Core Assembly And Checking Of Lv And Hv Leg Coils For Assessing Its Reuse, Rechecking And Recording Of Physical Dimensions Of Coil And Cleaning Of Core And Their Components Etc. 27 10Kva 28 25Kva 29 63Kva 30 100Kva 31 Reconditioning Of Minor Damaged In Hv / Lv Leg Coil / Strip Of Transformer. Work Includes Removing Of Damage Part Dpc Insulation And Providing New Dpc On Same Hv Coil / Lv Strip Should Be Properlycleaned And Should Be Made Of Same Size As Of Original . 32 25Kva 33 63Kva 34 100Kva 35 ‘‘Making Of Completelv Leg Alu. Leg Coils Identical To Original One With Same Number Of Turns, Weight Etc Providing Super Enameled / Dpc Conductor / Strip Confirming To Is 1971 / 53 In Place Of Old And Damage Coil. Alu. Coil, Wire Strip Will Be Provided By The Department. All Coil Assembly Of Identical Voltage Shall Be Interchangeable Without Requiring Any Special Equipment. Coil Shall Be Supported Between Adjacent Sections By Insulations, Spacers, Beamers And Other Insulations.Rewinding Shall Be Arranged To Ensure Free Circulation Of Oil To Reduced Hot Spots In Winding. The Insulation Of Coil Shall Be Treated With Suitable Insulating, Varnish Or Equivalent Compound To Develop The Full Electrical Strength Of Winding As Per Original Design. 36 10Kva 37 25Kva 38 63Kva 39 100Kva 40 ‘‘Making Of Complete Hvleg Alu. Leg Coils Identical To Original One With Same Number Of Turns, Weight Etc Providing Super Enameled / Dpc Conductor / Strip Confirming To Is 1971 / 53 In Place Of Old And Damage Coil. Alu. Coil, Wire Strip Will Be Provided By The Department. All Coil Assembly Of Identical Voltage Shall Be Interchangeable Without Requiring Any Special Equipment. Coil Shall Be Supported Between Adjacent Sections By Insulations, Spacers, Beamers And Other Insulations.Rewinding Shall Be Arranged To Ensure Free Circulation Of Oil To Reduced Hot Spots In Winding. The Insulation Of Coil Shall Be Treated With Suitable Insulating, Varnish Or Equivalent Compound To Develop The Full Electrical Strength Of Winding As Per Original Design. 41 10Kva 42 25Kva 43 63Kva 44 100Kva 45 Assembly Of Core And Coils And Fitting Of Other Parts Requiring Replacement Such As Press Board, Making Supports Between Adjacent Sections By Insulating Spares And Rapping Etc & Tapping Etc. ( Breezing / Soldering ) Required, Shall Be Arrange By The Contractor. 46 10Kva 47 25Kva 48 63Kva 49 100Kva 50 Shifting And Keeping The Assembled Core Coil Etc. In Oven From The Repairing And Assembly Place. 51 10Kva 52 25Kva 53 63Kva 54 100Kva 55 Taking Out Assembled Core And Coils Assembly From The Oven And Shifting To Repairing Hall. 56 10Kva 57 25Kva 58 63Kva 59 100Kva 60 Retanking Of Complete Assembly Into Painted Tank And Lightening Of The Assembly In The Tank Safely. Fitting Of All Accessories Of The Transformer. 61 10Kva 62 25Kva 63 63Kva 64 100Kva 65 Welding Of Repaired Transformers Including Of Top Cover Plate By Electric Core Welding Filling Of Gaps Or Fixing Of Top Cover Plate By Properly Nuts & Bolts To Prevent Seepage Of Water.. 66 10Kva 67 25Kva 68 63Kva 69 100Kva 70 Painting Of T / F Outside With Super Enamel Synethics Paint Of Yellow Color In Two Coats After Providing Primer Of Red Oxide Paint Etc. Paint & Painting Materials Shall Be Provided By Contractor. 71 10Kva 72 25Kva 73 63Kva 74 100Kva 75 Dragging Of Repaired T / F Upto The Test Cabin / Testing Place For Testing And Their Re-Dragging To Yard And Its Stacking At Indentified Place After Testing 76 10Kva 77 25Kva 78 63Kva 79 100Kva 80 Testing The Correctness Of Connection, Dvdf, No Load, Load Loss Test ( Where Available ) , High Voltage, Impedance Voltage, Short Circuit And Open Circuit Test, Voltage Ratio On Various Tap Position. 81 10Kva 82 25Kva 83 63Kva 84 100Kva 85 Punching And Welding Of M.S. Plate On Outside Of Transformer Of Size 100 Mm X 50Mm X 3 Mm Containing / Punching. ( A ) Of Unique Number As Decided By The Department With A Punch Head. ( B ) Date Of Repair. 86 10Kva 87 25Kva 88 63Kva 89 100Kva

Key Value

Document Fees
INR 3540 /-
EMD
INR 29400.0 /-
Tender Value
Refer document

BOQ Items

Name of Work: Repairing of 11/0.4kv 10,25,63 & 100 KVADamage TransformeratSahupuri Workshop Chandauli Under EWD Varanasi.
Sl. No. Item Description
1Handling and dragging of transformer from stacking yard to repairing hall.
210KVA
325KVA
463KVA
5100KVA
6Cutting of Sealed transformers top cover plate smoothly and uniformally by gas/chisel cutter or opening of top cover plat and detanking of core and coil assembly.
710KVA
825KVA
963KVA
10100KVA
11Dragging of the tank from the repaired hall to yard. & cleaning oil and dust etc. and scraping the rust etc andWashing of Transformer tank with Caustic Soda & water, Caustic soda shall be provided by contractor
1210KVA
1325KVA
1463KVA
15100KVA
16Painting of inner side of transformer tank and channels with heat proof zinc chromate paint of good quality (Berger, Nerolac, Jenson & Nicholson etc) shall be
1710KVA
1825KVA
1963KVA
20100KVA
21Dragging out empty tank from yard to repairing hall.
2210KVA
2325KVA
2463KVA
25100KVA
26Dismantling core and coil assembly and cleaning of dust and dirt from the core assembly and checking of LV and HV leg coils for assessing its reuse, rechecking and recording of physical dimensions of coil and cleaning of core and their components etc.
2710KVA
2825KVA
2963KVA
30100KVA
31Reconditioning of minor damaged in HV/LV leg coil/ Strip of transformer. work includes removing of damage part DPC insulation and providing new DPC on same HV coil/LV Strip should be properlycleaned and should be made of same size as of original .
3225KVA
3363KVA
34100KVA
35‘‘Making of completeLV leg Alu. Leg coils identical to original one with same number of turns, weight etc providing super enameled / DPC conductor/ Strip confirming to IS 1971 /53 in place of old and damage coil. Alu. coil, wire strip will be provided by the department. All coil assembly of identical voltage shall be interchangeable without requiring any special equipment. Coil shall be supported between adjacent sections by insulations, spacers, beamers and other insulations.Rewinding shall be arranged to ensure free circulation of oil to reduced hot spots in winding. The insulation of coil shall be treated with suitable insulating, varnish or equivalent compound to develop the full electrical strength of winding as per original design.
3610KVA
3725KVA
3863KVA
39100KVA
40‘‘Making of complete HVleg Alu. Leg coils identical to original one with same number of turns, weight etc providing super enameled / DPC conductor/ Strip confirming to IS 1971 /53 in place of old and damage coil. Alu. coil, wire strip will be provided by the department. All coil assembly of identical voltage shall be interchangeable without requiring any special equipment. Coil shall be supported between adjacent sections by insulations, spacers, beamers and other insulations.Rewinding shall be arranged to ensure free circulation of oil to reduced hot spots in winding. The insulation of coil shall be treated with suitable insulating, varnish or equivalent compound to develop the full electrical strength of winding as per original design.
4110KVA
4225KVA
4363KVA
44100KVA
45Assembly of core and coils and fitting of other parts requiring replacement such as press board, making supports between adjacent sections by insulating spares and rapping etc & tapping etc. (Breezing/soldering) required, shall be arrange by the contractor.
4610KVA
4725KVA
4863KVA
49100KVA
50Shifting and keeping the assembled core coil etc. in Oven from the repairing and assembly place.
5110KVA
5225KVA
5363KVA
54100KVA
55Taking out assembled core and coils assembly from the OVEN and shifting to repairing hall.
5610KVA
5725KVA
5863KVA
59100KVA
60Retanking of complete assembly into painted tank and lightening of the assembly in the tank safely. Fitting of all accessories of the transformer.
6110KVA
6225KVA
6363KVA
64100KVA
65Welding of repaired transformers including of top cover plate by electric core welding filling of gaps or fixing of top cover plate by properly nuts & bolts to prevent seepage of water..
6610KVA
6725KVA
6863KVA
69100KVA
70Painting of t/f outside with super enamel synethics paint of yellow color in two coats after providing primer of red oxide paint etc. paint & painting materials shall be provided by contractor.
7110KVA
7225KVA
7363KVA
74100KVA
75Dragging of repaired T/f upto the test cabin/testing place for testing and their re-dragging to yard and its stacking at indentified place after testing
7610KVA
7725KVA
7863KVA
79100KVA
80Testing the correctness of connection, DVDF, No load, load loss test (where available), High Voltage, impedance voltage, Short Circuit and open circuit test, Voltage ratio on various tap position.
8110KVA
8225KVA
8363KVA
84100KVA
85Punching and welding of M.S. Plate on outside of transformer of size 100 mm x 50mm x 3 mm containing/ punching. (a) of unique number as decided by the department with a punch head. (b) Date of repair.
8610KVA
8725KVA
8863KVA
89100KVA