Tender For Construction Of Feeder Channel, Pump House,Sump Well, Diggi, Supply And Installation Of Mono Block Pump And Boundary Wall Of Diggi At Tail Of Kolayat Disty And Laying Pipe Line For Kapil Sarovar, Bikaner-Rajasthan

Indira Gandhi Canal Project Rajasthan-IGCPR has published Tender For Construction Of Feeder Channel, Pump House,Sump Well, Diggi, Supply And Installation Of Mono Block Pump And Boundary Wall Of Diggi At Tail Of Kolayat Disty And Laying Pipe Line For Kapil Sarovar. Submission Date for this Tender is 17-08-2023. Pipe Laying Tenders in Bikaner Rajasthan. Bidders can get complete Tender details and download the document.




Tender Notice

38897887
Tender For Construction Of Feeder Channel, Pump House,Sump Well, Diggi, Supply And Installation Of Mono Block Pump And Boundary Wall Of Diggi At Tail Of Kolayat Disty And Laying Pipe Line For Kapil Sarovar
Open Tender
Indian
Rajasthan
Bikaner
17-08-2023

Tender Details

Construction Of Feeder Channel, Pump House, Sump Well, Diggi, Supply And Installation Of Mono Block Pump And Boundary Wall Of Diggi At Tail Of Kolayat Disty And Laying Pipe Line For Kapil Sarovar

Key Value

Document Fees
INR 10000 /-
EMD
INR 1000000.0 /-
Tender Value
INR 4.98 Crore /-

BOQ Items

Name of Work: CONSTRUCTION OF FEEDER CHANNEL, PUMP HOUSE,SUMP WELL, DIGGI, SUPPLY AND INSTALLATION OF MONO BLOCK PUMP AND BOUNDARY WALL OF DIGGI AT TAIL OF KOLAYAT DISTY AND LAYING PIPE LINE FOR KAPIL SAROVAR.
Sl. No. Item Description
1PART-A Building work
2Earth work in excavation in foundation, trenches or drain (not exceeding 1.50 m in width) including dressing of sides and ramming of bottom, lift up to 1.5 m including getting out the excavated soil anddisposals of surplus excavated soil as directed with a lead in a 50 m, All kind of soil.
3Filling available excavated earth (excluding rock) in trenches, plinth side of foundation etc in layer not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering including lead up to 50m and all lift.
4P & L in position cement concrete including curing compaction etc. complete using stone aggregate 40 mm nominal size in foundation plinth, excluding the cost of shuttering using 1 Cement:4sand:8 aggregate .
5Brick masonary in foundation and plinth with brick designation 75in cement sand mortar 1:5
6Add extra over item no.6 (a)For using brick class designation 100 instend of class designation 75,
7Extra for brick work in superstructure above plinth level for every 5 m and part thereof
8Centering & shuttering with plywood or steel including strutting, propping, bracing both ways with wooden members and removal of form work for superstructure up to 4.5 mtr. Height above plinth level including material. Suspended floors, roofs landings staircases landing, balconies, girders, cantilevers, bands coping bed plates, anchor blocks sills, chajjas etc.
9P/L cement concrete in R.C.Cwork for suspended floors, roofs girders, cantilevers, stair cases, landing, balconies, shelves, chajjas, lintels bands, coping, bed plates, anchored blocks, Sills & Beams etc. in super structure up tofloor three level including curing compaction finishing with rendering in cement sand mortar 1:3 ( 1 cement :3 coarse sand) & making good the joints excluding cost of shuttering and centering & reinforcement.M-20 grade mix 1:1½:3 (1 cement : 1½ coarsesand : 3 graded stone aggregate 20mm nominal size)
10Providing and fabricating steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and bindings complete including cost of binding wire in foundation and super structure 4.5 mtr. height above plinth level. Hot rolled deformed (IS 1139) cold twisted (IS 1786 ) bars
11Providing and Fixingunplasticised (UPVC) SWR pipes type B FOR SCILAND waste discharge system (is:13592:1992 mark) of approved quailty /make (i) single socketed pipes Tpye B 110 mm dia
12Providing and Fixingunplasticised (UPVC) SWR pipesfittings type B FOR SCILAND waste discharge system (is:13592:1992 mark) of approved quailty /make (i) single bend w/o door 87.5" 110 mm dia
13Cement Plaster with cement sand mortar 1:5 including racking of joints, smooth finishing and curing etc. complete including all leads of all materials of thickness 12 mm thick in 1 coats.
14Supply and fixing machine cut fine dressed Red/Pink sand stone dasa or coping with full moulding if required laid on cement mortar 1:4 including pointing with admixture of pigment matching with the stone shade 50mm thick.
15Cement concrete flooring grade 1:2:4 (1 cement, 2 course sand, 4graded stone aggregate) rounded off edge etc. but excluding the cost of nosing etc. complete,40 mm thick with 20 mm nominal size aggregate.
16Providing & fixing steel glazed doors, windows and ventilators with shutters of standred rolled steel section joint mitred and welded with steel 13x3mm lugs 10 Cm. long embedded in cement concrete blocks 15x10x10 Cm. of 1:3:6 (1-Cement:3-coarse sand:6-graded stone aggregate 20 mm nominal size) or with wooden plugs and screws or rawl plugs and screws or with fixing clips or with bolts and nuts as required, including providing and fixing of plain glass panes 4mm thick with copper glazing clips and special metal-sash putty of approved make, or metal beading with screws complete including priming coat of approved steel primer, excluding the cost of metal beading and other fittings except necessary hinges of pivots steel handles and peg stay etc. as required.
17Providing and fixing welded mesh/expanded metal mesh in frame work, flat iron beading 20x3mm including top cross laps inside and out sides welding, iron bolts, crews, clips etc. complete (excluding frame work) of size. Welded mesh 25mmx25mmx2.10mm
18Providing and fixing T-iron frames for doors window and ventilators of mild steel tee-sections, joints mitered and welded with 15x3 mm lugs 10 cm long embedded in cement concrete blocks 15 x 10 x 10 cm of 1:3:6 (1 cement :3 course sand : 6 graded stone aggregate 20mm nominal size) or with wooden plug and screw or rawl plugs and screws of with fixing clips or with bolts and nuts as require including fixing of necessary but hinges and screw and applying a priming coat of approved steel primer.
19Providing and fixing MS sheetdoors, shutter in angle iron frame 35 x35 x5mm suitably diagonally braced with 25 x3mm flat iron above and below lock rail of size 50 x5mm beading extra including all fitting, as per direction of Engineer Incharge but excluding cost of Chowkhats : including two coats of anti corrosive red oxide primer paint MS sheet 22 S.W.G
20(a) Single leaf shutters
21(b) Double leaf shutters add extra 20 % in item no 17 (a)
22Distempering with 1st quality Acrylic washable distemper (ready mixed) of approved manufacturer and of required shade and colour complete including all scaffolding as per manufacturers specification. Two or more coats on new work including preparation of base with primer, putty, lippy etc. complete in all respect.
23Finishing walls with Acrylic smooth exterior paint of required shade including all scaffolding. New work(Two or more coat applied @ 1.67 Ltr./10 sqm over and including base coat of water proofing cement paint applied@20.20 kg/10sqm).
24Painting withenamel paint of approved brand and manufacture to give an even shade. : two or more coats on new work.
25P & F Indian type white glazed vitreous china Ist quality WC Orissa pan (IS : 2556 Mark) with 100 mm vitreous China p or S trap including cutting and making good the wall and floor/ Size 580 x 440 mm
26P & F G I pipes (External works) with G I fittingexcluding union( IS: 1239 Mark) including trenching & refilling earth etc. 15 mm dia nominal bore Class - B
2725 mm dia nominal bore type b
28P&F Bib cock(is:8931 mark) superior quailty of approved make( brass 400 gm 15 mm nominal bore)
29P & F Storage tank ( IS : 12701 marked indicated the BIS license No), approved make with cover, 25 mm dia IM long G I over flow pipe & 25 Cm long wash out pipe with plug & socket, including making connection etc. complete of approved design.( 500 ltrs)
30P & F Flush Cock/flush valve ( IS:9758 Mark) for W/C of approved quality make.CP brass half turn Exposed 25 mm nominal bore.
31Construction of soakage well in all type of soil with 300 mm thick dry masonry, top and bottom 300 mm course in CM 1:6, 80mm thick stone slab, jointing of slab in CM 1 : 3, Ralthal, Kharanja, 40 mm thick M-15 grade C.C flooring , earthwork complete as per approved drawing including disposal of earth within a lead of 50 mtr.: 3.22.1 Size 300 Cm. dia outside & 300 Cm. depth
32Providing and Laying and jointing Glazed S W Pipe grade A ( IS 651 marked) of approved make with spun yarn and stiff mixer of cement mortar 1:1 excavation and refilling of earth in all type of soil upto 1.20 mtr depth S W fitting including testing of joints etc complete. 100 mm dia
33Providing & Laying C.C. 1:5:10 (Stone aggregate 40mm nominal size) all around S.W. pipe including 15 Cm. thick bed concrete (Width W= Diameter of pipe in Cm+30 Cm.)( Excluding cost of pipe) 100mm dia S.W. Pipe.
34Providing and laying cement concreting including curing, compation etc. complete using stone aggregate 20 mm nominal size in foundition and plinth, excluding cost of shuttering using. M-15 grade mix 1:2:4 (1 Cement:2 coarse sand: 4 graded stone aggregate)
35Making khurras 450 x 450mm with average minimum thickness 50 mm cement concrete 1:2:4 over P.V.C. Sheet 1 Mtr. x 1 Mtr. x 40 micron finished with 12 mm cement plaster 1:3 and one coat of neat cement, rounding edges and making and finishing the out let complete.
36Electrification of Pump House
37Wiring of light point/fan/exhaust fan point/cell bell point as per PWD specification for electrical woeks with ISI marked 1.5 sq. mm nominal size FR PVC insulated unsheathed flexible copper conduct 1.1 KV grade(IS:694) and 1.50 sq mm nominal size FR PVC insulated unsheathed flexible copper earth conductor 1.1 KV grade (IS 694) in recessed ISI marked (IS (IS:9537 P-II) rigid steel conduit & its all accessories, round tiles,18 SWG G.I box with earth terminal, 6 A switch, 3 pin celling rose/ Lamp holder/ 3 point connector,3.0 mm thick ISI marked phenolic laminated sheet, PVC bushes, check nuts, Ai. alloy/ cadmium plated iron screws 20mm cup washers etc. All as per pre approved by Engineer in charge, making connections, testing etc. complete as per required. For specification of copper conductor, phenolic Laminated sheets & Electrical/ wiring accessories refer Chapter E-05& E-07. For additional technical parameters of products/ work, refer Annexure "A" attached with this BSR.
38i- shortpoint(upto 3 Mtr)
39ii- medium point ( Upto 6 Mtr)
40iii- long point (Upto 10 mtr)
41Wiring of 3/5 pin6 amp. Litght plug point as per PWD specification for electrical work with ISI marked 1.5 sq. mm nominal size FR PVC insulated unsheathed flexible copper conduct 1.1 KV grade( IS:694) in and 1.5 sq mm nominal size FR PVC insulated unsheated flexible copper earth conductor 1.1KV grade (IS: 694) in recessed ISI marked (IS:9537P-II) rigid steel conduit & its all accessories, required size 18 SWG, G.I. box with earth terminal,6A switch,3/5 pin 6A socket,3.0 mm thick ISI marked phenolic sheet pvc bushes, check nuts, Al. alloy/ cadmium plated iron screws 20mm cup washers etc. All as per pre approved by Engineer in charge, making connections, testing etc. complete as per required. For specification of copper conductor, phenolic Laminated sheets & Electrical/ wiring accessories refer Chapter E-05& E-07. For additional technical parameters of products/ work, refer Annexure "A" attached with this BSR. On board
42Providing & Fixing of 240/415 V MCB with positive isolation of braking capaciy not less then 10 KA ( B/C tripping characteristic as per type of load and site requirement) 4KV impulse withstand voltage, as per PWD specification for electrical works with ISI marked IS 8828(1996)/ conforming to IEC 60898-1 2002,IEC 60947-2 low watt losses, trip free mechanisum, energy limiting of class 3 as per IEC, minimm phase termination capacity of 35sq.mm, conductorline load reversibility, label holding acility, IP 20 contact protection and fitted with existing distribution board/sheets, min. operation 20000 upto 32 A rating and 10,000 upto 63 A, 5000 for 80 A rating including making cannections testing etc. as required. OEM shall have submit NABL/CPRI/ERDA accrediated lab test report before execution & all as per pre approved by Engineer in charge. For additional technical parameters of products/ work, refer Annexure "A" attached with this BSR ( Double pole MCB 40 A rating)
4363A rating Group II
44P & F 18 swg MS Recessed fan box hexagonal/round of size 130 mm dia, depth 75mm, 12mm dia rod fan hook with 100mm length extended on each side.All as per pre approved by Engineer in charge. For additional technical parameters of products/ work, refer Annexure "A" attached wit this BSR
45Providing & Fixing of energy efficient /energy saving IP 20 LED direct retrofit Bulb in existing holder or fixture as required with system lumen efficacy =100 lm/Watt output pf 0.95, CRI >70, minimum life time of minimum 25000 Burning Hours with, 70% of intial Lumen maintaned till ife ends, CCT 3000°K / 4000"K 5700K /6000"K/6500"K (As per ANSI Bin) maximum power consumption should not more than the specified rating and Fixture shall be of BIS standard andtrade mark certificate ( TC).Manufactures word mark/name Engraved/embossing/screen painting on housing OEM must have its own in house NABL lab setup for all testing facilites for LED fixtures (LM 79/LM80 ) certificate/report from OEM shall be submitted. All as per pre approved by engineer in charge for additional technical parameters of product/ work, refer Annexure "A" attached with this BSR.15 Watt
46Supply and erection of M.S. galvanized Octagonal pole( as per BSEN 40-3-3:2003/ BSEN 10025/IS 2062 IS:875 Part-1-2015/ for MS plate for base glange) of following length and dimension as per table P-01 with base plate on the cement concrete foundation of M-20 grade(1:1.5:3) as per IS 456/2911. with the help of anchor bolts of grade 6.8 (IS:1367 P III). The pole shall have a weatherproff flush door and locking arrangements. complete in all respect. All as per pre approved by Engineer in charge. For additional technical parameters of products/ work, refer Annexure "A" attached with this BSR.( 8 MTR)
47LED Street Light fixture 45 Watt
48Labour charges for Excavation of 30cmX75cm size tranch in loose soil including refilling of excavated earth, compaction of earh, makingbgood the same complete as required.
49Providing & Laying / XLPE insulated & P.V.C. sheathed un-armoured/ Armoured copper cable of 1.1 KV grade as per PWD specification for electrical works in existing RCC/Hume/Stoneware/PVC pipe/ open duct/ cable tranch with filling of wxcavated earth in tranch, on existing cable trays or on surface etc. including making necessary connection, testing etc. as required of size and as per points (a),(b),(c) mentinoed below:- (a) Copper conductor of electrlytic grade copper, purity>99.97% ISI marked as per IS:1554 P-1/IS:7098 P-1(B) Conductor shall made of copper rods confirming to IS 613-1964,IS 3975-1999 for sheath IS 10810 (Part 0 to 64) for testing procedures.(c) OEM must have ISO 9001 & 14001 certifications & its own in house NABL lab setup for all testing facilities for cables. Appropriate type test certificate/ OEM test report shall be submitted.All above as per pre approved bu Engineer in charge. For additional technical parameters of product/work,refer Annexure "A" attached with this BSR.(2.5 sq.mm 2 core)
50Providing & Fixing of IK07 IP 66 protected LED Street Light Luminaire on existing bracket/pole. Fixture made of powder coated single piece pressure die cast aluminum LM6/ ADC12 material with heat dissipation fins on housing with UV stabilized PC/Toughened Glass cover (UV stablzation report submitted for UV cover ) and secondary lens on each LED & should be SMD type.The system level luminaire efficacy>=120 lm/wt wit high power LEDs is to be used and potted driven must be potted & has a unique BIS R number with input voltage AC 120 to270 V AC with voltage cutoff@>=300 V AC and auto resetting safty, input Frequency 50 HZ+-3% power factor> 0.95 driver efficiency >85%, THD(I)<1% humidity 10% to 90% RH working temp-5C to 45C. driver curent< 1000mA shown in LM79 report. the luminaire shall be BIS certified and T.C. certified. life expectancy equal or more tha 50000 buring hrs with minimum 70% lumen maintened, color rendering index>70 and CCT 5700K +355K. Surge protection shall be min>4 kv internal and min 10 kv external. driver should be phase to phase protection of 440 v for 4 hrs. Manufactures word mark/name engraved/embossing on die cast housing to allow traceability/authenticity. Fixture shall be AS per IS 10322 Coplianced. OEM must have its own in house NABL lab setup for all testing facilities for LED fixtures. (LM79/LM80) Certificate/report with liable warranty of product/accessories from OEM shall be submitted all as per pre approved by Engineer in charge. For additional technical parameters of products/work, refer Annexure"A"attached with this BSR.(LED Street light fixture 100 watt).
51P & F paper phenolic resin bounded laminated confirming to IS : 2036-1995 for boxes/ frames including making holes for switches etc with brass/ zinc plated screws, washers, nut and bolts as required. All as per pre approved by Engineer in charge. For additional technical paremeters of products/work, refer Annexure "A"attached with this BSR 4.8 mm thickGroup I
523x 2.5 sq mmGroup I
53P & F of ISI marked (IS:1258) 6amp batten/angle lamp holder as per PWD specifications for electrical works made out from industrial grade polycarbonate or fire resistant making connection testing etc. As required all as per pre approved by Engineer in Charge. for additional technical parameters of products/work refer annexure "A" atteached with this BSR
54Providing & Fixing of non modular socket size flush type 120 watt rotary minimum 5 step fan regulator as per PWD specification for electrical Works, ISI marked (IS:11037) made out from industrial grade Polycarbonate or fire resistant ABS material including making connection testing etc. as required. all as per pre approved by Engineer in Charge. for additional technical parameters of products/work refer annexure "A" atteached with this BSR
55Supplying and drawing FR PVC insulated and unsheathed flexible copper conductor as per PWD specifications for electrical withISI marked ( IS: 694) and as per IS 8130 : 2013 of 1.1 KV grade wire should be made from 99.99% purity copper, class 5 stranding in acc. to IEC 60228 for lower watt loss, oxygen free (<10ppm) for less chances of oxidization and higer silver content for gives better conductivity, insulation PVC type A, flame retardent as per IS 10810-53, better amprage rating as per VDE 0298 part 4, in existing surface or recessed PVC/MS conduit/casing capping including or as per pre approved by Engineer in Charge, making connections, etc. as required. OEM must have its own in house NABL lab setup for all testing facilities for wires. for additional technical parameters of products/work refer annexure "A" atteached with this BSR
56Providing & Fixing of IK09 recessed/surface mounting heavy duty horizontal type sheet steel of1.6 mm thick Distribution board as per PWD specification for electrical works ISI marked conforming to IS-13032 & IS-8623 / conforming to IEC 61439-3.Phosphatised/ powder painted complete with suitable rating insulated copper bus bar, shorting link, neutral link, earth link, connecting wire of suitable rating and din bar,masking sheet, including making internal DB terminations with copper lugs and with detachable gland plate, including makingconnections, testing etc.as required.OEM shall have submit NABL/CPRI/ERDA accrediated lab test reports before execution & All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure "A" attached with thisIP-43 Double door (single phase)8 Way (8 O/G +2 I/C)
57Providing & Fixing of ISO Certified company made BEE star rated copper wounded double ball bearing capacitor start, aluminium body & metallic blade ceiling fan as per PWDspecification for electrical work, conforming to IS :374-2019&IS:1885-P-V1981. with down rod up to 30 cm with secondary support safaty cable(steel wire),cotter pin with 3x1.5 sq.mm pvc insuleted flixible copper conductor making connection testing etc.as required Appropriate OEM test certificate shall be submitted by chsrge. Foe refer Annexure"A"attached with this BSR( 1200 MM Sweep bee 2 star rated(service value>=5.0to<5.5)
58PART-B Constg of Diggies
59E/W excavation in ordinary soil undressed inclusive of all lift but with combined lead upto 200 mtrs
60Extra for laying earth in 15 to 20 cm layers, watering, dressing but excluding cost of Rolling. Extra for rolling of earth to 90 % of maximum dry density of soil by mechanically driven machines , rollers or Vibro compactors as per requirement ofthe soil. (i) Ordinary soil
61Supplying HDPE film 300 micron as per IS code
62Single PCC block(M-15) lining 74 mm thick with PCC blocks size 30x15x4 cms in bed laid in 6mm thick cement mortar1:3 ( 1cement:3 bajri) over base plaster of 12mm thickin CM 1:6 ( 1 cement: 6 Bajri& 16mm thick sand witch plaster in CM 1:3 ( 1cement:3 bajri)including Mechanical Mixing of Mortar, Dressing of Bed Scaffolding Laying and Jointing of LDPE/HDPE and curing28 days complete as per specifications excluding cost of HDPE film but including cost of jointing material
63in sides (Single PCC block M-15)
64P and L Cement concreting including curing compaction etc complete using stone aggregate 20mm nominal size in foundation and plinth, excluding cost of shuttering using M10 grade mix 1:3:6 (1 cement:3 Bajri, 6 graded stone aggregate)as per specification
65Brick masonry in foundation and plinth with brick designation 100 in cement mortar 1:5
66(a)For using brick class designation 100 instend of class designation 75
67Cement Plaster with cement sand mortar 1:4 including racking of joints smooth finishing and curing etc complete including all leads of all construction material of thickness 12 mm in 1 coats.
68120 cm high fencing with angle iron posts 50x50x6 mm placed at every 3.0 mtr apart 30 cm in ground embedded in CC 1:3:6 (30x30x45 cm) corner and every tenth post to be strutted with 50x50x6 mm angle iron provided with 3 horizontal line and 2 diagonal of blackbarbed wire between two post fitting and fixed with G I staple including earth work in excavation etc complete
69Providing and fixing steel gate grating and grills made of angles tees square bars or other flats black pipes with hold fast and fitting complete as per design and drawing including cutting welding and fabrication with priming coat of red oxide
70PART-C Feeder Channel
71E/W excavation in ordinary soil undressed inclusive of all lift but with combined lead upto 200 mtrs
72Brick masonry in foundation and plinth with brick designation 75 in cement mortar 1:5
73(a)For using brick class designation 100 instend of class designation 75
74Cement Plaster with cement sand mortar 1:3 including racking of joints smooth finishing and curring etc complete including all leads o all construction material of thickness 10 mm. in One Coat
75PART-D Sump Well (Tank)
76E/W excavation in foundation trenches or drains ( not exceeding 1.50 mtr in width) depth, includingdressing of sides and ramming of bottom lift up to 1.50 mtr including getting out the excavated soil and disposal of surplus excavated soil as directed with in a lead of 50 mtr all kind of soil.
77(Add extra for one additional lift of 1.50 mtr)
78Providing laying cement concrete including curing compaction etc. complete using stone aggregate 20mm nominal size in foundation plinth, excluding cost of shuttering (M-10) grade mix 1:3:6
79Brick masonary in foundation and plinth with brick designation 75 in cement snd mortar 1:5
80(a)For using brick class designation 100 instend of class designation 75
81Providing laying cement concrete including curing compaction etc. complete using stone aggregate 20mm nominal size in foundation plinth, excluding cost of shuttering (M-15) grade mix 1:2:4
82Cement Plaster with cement sand mortar 1:4 including racking of joints smooth finishing and curing etc complete including all leads of all construction material of thickness 12 mm in 1 coats.
83Providing and laying jointing R.C.C class NP-2 non pressure pipe ( IS 458 make ) of approved make with collar jointed with CM 1:2 or heaving spigot and shocket ends with flexible rubber ring joint including testing joints etc. complete 300mm dia internal
84Providing and fixing steel gate grating and grills made of angles tees square bars or other flats black pipes with hold fast and fitting complete as per design and drawing including cutting welding and fabrication with priming coat of red oxidefor sumpwell cover
85PART-E BOUNDARY WALL
86Construction of boundary wall of Brick/ stone masonary as per enclosed GA drawing, scope of work and technical specifications complete work in all respect. Brief details of boundary wall parameter is as below: 1. Depth of foundation- 900 mm. 2. PCC in M-10, width -900 mm and thickness 100 mm, 3. Stone masonary in CM: 1:6 section of foundation above PCC,600 mm (W )x 450 mm (D) and 450 mm (W) x 450 mm (D) 4. Superstructure work: Stone masonary in CM: 1:6, W-300, height-1650 mm,/ Brick work in CM: 1:6 W-230 mm, height- 1650 mm. 5. Cement mortar pointing on Stone masonary and cement mortar plaster 20 mm thick on brick masonary in CM 1:6. 6. Expansion joint shall be on every 30 mtr. 7. On top of wall there shall be CC Coping 75 mm thick (1:2:4) shall be provided. 8. Pillar for main gate 350x350 mm in size is part of boundary wall. 9. Cement paint of approved colour in 3 coat shall be done.
87Structural steel work in single section fixed with or without connecting plate including cutting, hoisting (height upto 10 m ), fixing in position and applying a priming coat of approved steel primer all complete.
88Providing and fixing steel gate grating and grills made of angles tees square bars or other flats black pipes with hold fast and fitting complete as per design and drawing including cutting welding and fabrication with priming coat of red oxide
89Painting with synthetic enamel paint of approved brand and manufacture to give an even shade :(a)two or more coats on new work ( Pwd BSRP.NO :-B-12 ITEM NO 12.48,12.48.1)
90Pipe Net work and Mono Block pump
91Providing, lowering, laying and jointing in trenches,  standard lengths HDPEISI marked Pipes as per IS-4984: 1995 (amended up to date)with necessary jointing material like mechanical connectors, i.e. thread/ insert joint/ quick release coupler joint/ compression fitting joint or flanged joint and specials jointing pipe by butt fusion/ electro fusion welding method, including all taxes , transportation and freight charges, inspection charges, loading/ unloading charges, stacking of pipes, including cost of labour and material, specials (Tee, bend etc.), satisfactory hydraulic testing, disinfection, commissioning etc. complete as per technical specifications and direction of Engineer-in-charge of following class and diameter. (excluding earth work). Note : Providing and fixing of all requisite specials as per drawing, design and layout are inclusive in RM measurement of the item and shall not be paid separately. Supply of pipe shall be in straight length in 6/12 M.(HDPE PE-100 PN-10)
92dia 225mm
93dia140 mm
94Earth work in excavation by mechanical means (Hydraulic Excavator )/ manual means in trenches of required width and gradient for laying and jointing of pipe line including excavation for sockets, and dressing of sides, ramming of bottoms, depth up to 1.5 Mtr. including taking out the excavated soil, and then returning the soil as required in layers not exceeding 20cm in depth including consolidating each deposited layer by ramming, watering etc. and disposal of surplus excavated soil as directed within a lead of 50 Mtr. including required all safety provisions etc.: All kinds of soil
95Earth work excavation in ordinary soil, undressed inclusive of all lift bt with combined lead up to 200 mtrs.
96Providing and laying cement concreting including curing, compation etc. complete using stone aggregate 20 mm nominal size in foundition and plinth, excluding cost of shuttering using. M-10 grade mix 1:3:6 (1 Cement:3 coarse sand: 6 graded stone aggregate)
97Brick masonary in foundition and plinth with brick designation 75.(d) In cement sand motor 1:5
98Providing and laying cement concreting including curing, compation etc. complete using stone aggregate 20 mm nominal size in foundition and plinth, excluding cost of shuttering using. M-15 grade mix 1:2:4 (1 Cement:2 coarse sand: 4 graded stone aggregate)
99Cement plaster with cement sand motor (1:5) including racking of joints, smooth finishing and curing etc. complete including all leads of all construction materials of thickness. 12 mm thick in 1 coats.
100Providing,lowering, aligning,fixingin positionin pipeline,CID/FSluicevalvesstraight and pocket less body passage of approved make of following Pressure rating & dia complete, confirming to IS:14846 (amended up to date) and of following specifications: Body, Bonnet, Wedge, Gland, Thrust Plate, Cap & Hand wheel of Grey cast iron of IS:210/ FG200Stem - SS 304 ,Body Seat ring, Wedge facing ring & Bushes - LTB2/ SS, Face to face dimensions as per IS 14846/2000 (amended up to date) ,Epoxy ( Non-Toxic- suitable for drinking water) applied inside and outside,Flanges Drilled as per IS 1538. Nut-Bolt confirming to IS:1363 and IS: 1367/ CS/ galvanised steelInsertion rubber of black EPDM 6mm thick . Sluice valves including all jointing & jointing material, labour, testing and commissioning along with pipe line as per Technical Specifications and as per direction of Engineer-in-charge. Note: Rates are exclusive of tail piece/ dismantling joints and earth work.Dia 250mm HW
101Providing supplying installing hydraulic pressure relief valve of following size 65 mm dia
102Providing, lowering, aligning, fixing in position in pipe line, CI double flanged swing type Non Return Valves (NRV)of approved make of following Pressure rating & dia complete, confirming to IS: 5312 (part -1)/ 2004 (amendedup to date) and of following specifications: Body, Cover & disc of Grey cast iron of IS:210/ FG200. Face to face dimensions as per IS 5312 (part -1):2004 , Flanges Drilled as per IS:1538. Epoxy(Non-Toxic & suitable for drinking water) applied on body, cover and disc inside and outside . Body seat ring of SS/CS Door face ring - EPDM/ Neoprene (food grade quality) ,Shaft of HTB1/ SS- AISI- 410 ,Hinge Malleable cast iron / SS AISI 316/410 ,Bonnet Gasket EPDM, Bush- Leaded tin Bronze/ PTET, GasketEPDM/NBR,Nut-Bolt as per IS:1363 and IS: 1367 (galvanised steel) ,Insertion rubber of black EPDM 6mm thick. Suitablesupport structure as per directions of EIC including jointing & jointing material, labour, testing and commissioning along with pipeline as per Technical Specification & as per direction of Engineer-in-charge. Note: Rates are exclusive of tail piece/ dismantling joints and earth work.Dia 250mm
103Providing installation testing and commissioning of glycerin filled pressure gauge of following ranges with isolation valve and tape of pipe complete in all respect as per techinical speciflcation and as per direction of engineer 0 to 6.0 kg/cm²
104PART-B Mono Block
105Desiging, supplying construction, installation, testing & commissioning of motor driven Horizonatal Centrifugal Pumping sets of monoblock type for operation on 3 phase 50 HZ AC supply betwwen 300 to 440 voltage ranges and SAND CAST SS Impeller. The set should as per IS 9079-2002 with latest amendment .
10625 H.P + Stand by
107Providing and fixing suction pipe to pipe inlet and delivery pipe from pump outlet to raising mains of respectine section with M.S. medium class pipe with required pipe and pipe fittings Such as flanges, bends, tees, reducer, enlarger, tail pipeces, blind flanges, puddel collar dismanteling pieces, nut & bolts gaskents, etc including foot valve and suction strainer. 125mm dia.
108Supply and fixing of electric control panel of 16 SWG (CRCA) in masonry wall for suitable for 2 Nos. electric driven pump sets comprising MCCB, MCB, automatic star delta starer, phase indicator, lighting arrangement etc. complete suitable for three phase pump set. All these equipments shall be fixed on 12 mm thick backalite sheet which fixed on M.S. angle frame of size 1800x1200 i.e made angle iron 50x50x6 mm including making good the surface of wall
10930 HP
110Providing and laying PVC insulated and PVC sheathed cable of 1.1 KV grade with alluminium conductor of IS : 1554and Group-I approved make incluing testing exsting extra etc. as required of size.Laid in open duct
11125 sqmm 4 core (Armoured)
112Providing and laying PVC insulated and PVC sheathed cable of 1.1 KV grade with alluminium conductor of IS : 1554and approved make incluing testing exsting extra etc. as required of size.
11316 sqmm 4 core (Armoured)
114Earthing with G.I earth plate 600mm x 600mm x 6 mm thick including accessories embodying by digging 3 to 4 mts below the ground level and refilling with 6 to 10 alternate layers of salt and charcoal and providing masonry enclosure with cover plate and watering pipe with funnel etc. as per I.S 3043 complete as required.
115Providing and installing hydrocyclon filter IS (14743) capacity of 120 cum per hrs 150 mm.
116P& F G.I. pipes with G.I. fittings excluding nion (IS: 1239 Mark) including trenchig & refilling earth etc.:-(Extrenal Work) Medium Duty Pipes: 80 mm dia nominal bore class A
117" Supply laying and pushing of MS casing pipe of specified thickness approved by concerned department authority by trenchless method adopting any suitable technology below ground at required depth under running traffic condition as per Highway/ Railway standard including carrying out survey work at the job site for determining underground cable trenches like telephone, cable, water & sanitary lines and resistivity test for finding the soil strata using necessary equipments for completion of works, mobilizing of machineries and specialized crew at the job site complete in all respect, including excavation of driven pit and exit pit (up to 3 meter depth) with proper protection at these sites with shoring sheets and ISMB. Providing MS cutting edges for front shield and constructing thrust bed at designated level. Necessary dewatering and providing concrete foundation at the base of the driven pit, PVC/Rubber saddle as per the requirement of Highway/Railway authority, crane for handing of pipe and any other machinery, tools, and tackles required, construction of temporary works as per design, drawing and method as per approved byauthority specification and the direction of the Engineer. Apply corrosion, resistant, protection on inside and outside of casing pipeas per technical specification. "400 mm Dia 8 mm thick casing pipe .
118OPERATION & MAINTENANCE
119Operation and maintenance of already installed pumping machinary including repairing of pump set, electric panel etc.
120Operation and maintenance of various size HDPE pipe line including patrolling, dewatering, T & P transportation of jointing material, reparing of pipe line removal of choking of pipe line and operation of valve etc.For 18 months
Disclaimer :