Tender For Repair/Maintenance Of Lt Panels, Lt Ug Cable And Certain Allied Connected Works At Metcalfe House And Repair/Replacement And Maintenance Of Vrf System And Other Connected Works In Bhaskar Building At Metcalfe House Under Ge (I) Rnd Delhi, delhi-Delhi

Statutory Bodies & Commissions/Committees has published Tender For Repair/Maintenance Of Lt Panels, Lt Ug Cable And Certain Allied Connected Works At Metcalfe House And Repair/Replacement And Maintenance Of Vrf System And Other Connected Works In Bhaskar Building At Metcalfe House Under Ge (I) Rnd Delhi. Submission Date for this Tender is 04-09-2023. Electrification Work Tenders in delhi Delhi. Bidders can get complete Tender details and download the document.




Tender Notice

38895591
Corrigendum : Tender For Repair/Maintenance Of Lt Panels, Lt Ug Cable And Certain Allied Connected Works At Metcalfe House And Repair/Replacement And Maintenance Of Vrf System And Other Connected Works In Bhaskar Building At Metcalfe House Under Ge (I) Rnd Delhi
Open Tender
Indian
Delhi
Delhi
04-09-2023

Tender Details

Repair / Maintenance Of Lt Panels, Lt Ug Cable And Certain Allied Connected Works At Metcalfe House And Repair / Replacement And Maintenance Of Vrf System And Other Connected Works In Bhaskar Building At Metcalfe House Under Ge ( I ) Rnd Delhi. 1 M&L For Painting Of Lt Panel Indoor / Outdoor Type With Two Coats Of Synthetic Enamel Heat Resistant Grey Paint Including Preparation Of Old Painted Surfaces / Removing Old Faded / Rust / Cemented Material Of Using Spray Gun Surface Of Complete Lt Panel Complete All As Specified And Directed. 2 M&L For Replacement Of Old Rusted Mild Steel Angle Iron Work And Fixing / Fabrication Of Angle Iron Frame 40X40x5mm Thick For Lt Panel Complete Clamps, Nut Bolts And Necessary Fixing Arrangements At Site Complete All As Specified And Directed. 3 M&L In Repair To Lt Panel Body Of Any Size / Make Including Cutting, Welding Of Front Panel, Replacement Of Back Cover And Top Covermade Of Crca Steel Sheet Of Size Not Less Than 3.15Mm Thick, Matching With Existing Including Hinges And Locking Devices Complete All As Specified And Directed. 4 S&F In Replacement Of Aluminium Bus Bar Pvc Insulated In Red, Yellow, Blue & Black Colours Of Rating 400 Amps Complete All As Specified And Directed. 5 S&F In Replacement Of Aluminium Bus Bar Pvc Insulated In Red, Yellow, Blue & Black Colours Of Rating 800 Amps Complete All As Specified And Directed. 6 S&F In Replacement Of Aluminium Bus Bar Pvc Insulated In Red, Yellow, Blue & Black Colours Of Rating 1500 Amps Complete All As Specified And Directed. 7 S&F In Replacement Of Insulator Of Appropriate Size As Per Existing One Complete All As Specified And Directed. 8 M&L For Taking Shutdown The Lt Panel And Disconnecting The Power Cable For Necessary Repair And Servcing Of Acb 800 Amps To 1000 Amps Including Necessary Spare Parts And Testing Complete Includingcomplete All As Specified And Directed. Note :- Unserviceable Spare Parts Replaced Shall Be Deemed To Be Included In Quoted Rates. 9 All As Per Item Ser No 8.00 Above But Acb Of Capacity 1000A To 2000A 10 S&F In Replacement Of Acb 800 Amps 4 Pole With Thermal Magnetic Release ( Manual Fixed Type ) Completeall As Specified And Directed. 11 All As Per Item Ser No 10.00 Above But Acb Of Capacity 1000 Amps. 12 All As Per Item Ser No 10.00 Above But Acb Of Capacity 1250 Amps. 13 All As Per Item Ser No 10.00 Above But Acb Of Capacity 2000 Amps. 14 Disconnecting, Taking Out Old Unserviceable Joints & Supplying, Fixing, Jointing & Testing For Provision Of Straight Through Joints, Heat Shrinkable Epoxy Tube With Epoxy Jointing Materials Suitable For Xlpe Lt Cable 1100 Volts Grade, For Size 50 To 95 Sqmm 3.5 Core Complete All As Specified And Directed. 15 All As Per Item Ser No 14.00 Above But Size 120 Sqmm To 185 Sqmm 3.5 Core. 16 All As Per Item Ser No 14.00 Above But Size 240 Sqmm To 300 Sqmm 3.5 Core. 17 All As Per Item Ser No 14.00 Above But Size 400 Sqmm To 630 Sqmm 3.5 Core. 18 Disconnecting & Taking Outold Unserviceable Joints & Supplying, Fixing, Jointing & Testing For Indoor Termination Joint Kits, Heat Shrinkableepoxy Tube With Epoxy Jointing Materials Suitable For Xlpe Lt Cable 1100 Volts Grade Indoor For Size 95Sqmm To 185 Sqmm 3.5 Core Complete All As Specified And Directed. 19 All As Per Item Ser No 18.00 Above But Size 240 Sqmm To 300 Sqmm 3.5 Core. 20 All As Per Item Ser No 18.00 Above But Size 400 Sqmm To 630 Sqmm 3.5 Core. 21 S&F 3 Pole Mccb, 100 Amp, 50 Hz, 415 V With Rupturing Capacity 16 Ka Including Taking Out Old Unserviceable Mccb Complete All As Specified And Directed. 22 All As Per Item Ser No 21.00 Above But Mccb 3 Pole 125 Amp, 16 Ka 23 All As Per Item Ser No 21.00 Above But Mccb 3 Pole 160 Amp, 25 Ka 24 All As Per Item Ser No 21.00 Above But Mccb 3 Pole 250 Amp, 36 Ka 25 All As Per Item Ser No 21.00 Above But Mccb 3 Pole 400 Amp, 36 Ka 26 All As Per Item Ser No 21.00 Above But Mccb 3 Pole 630 Amp, 50 Ka 27 S&F 4 Pole Mccb, 160 Amp, 50 Hz, 415 V With Rupturing Capacity 36 Ka Including Taking Down Old Unserviceable Mccb Complete All As Specified And Directed. 28 All As Per Item Ser No 27.00 Above But Mccb 4 Pole 250 Amp, 36 Ka 29 All As Per Item Ser No 27.00 Above But Mccb 4 Pole 400 Amp, 36 Ka 30 All As Per Item Ser No 27.00 Above But Mccb4 Pole 630 Amp, 50 Ka 31 All As Per Item Ser No 27.00 Above But Mccb 4 Pole 800 Amp, 50 Ka 32 S&F In Repair Digital Multifunctional Meter As Per Matching To Existing Including All Accessories And Wiring Complete All As Specified And Directed. Make:- Ae / L&T Or Equivalent As Approved By Ge. 33 S&F In Repair Power Factor Meter Digital Type For Frequency Range ( 45-65 Hz ) As Per Matching To Existing Including All Accessories And Wiring Complete All As Specified And Directed. Make:- Ae / L&T Or Equivalent As Approved By Ge. 34 S&F In Repair Three Phase Overcurrent Earth Fault Relay Mc-61 As Per Matching To Existingincluding All Accessories And Wiring Complete All As Specified And Directed. Make:- Ae / L&T Or Equivalent As Approved By Ge. 35 Supply & Laying In Replacement Lt Cable Xlpe Insulated , Screened, Pvc Bedded, Galvanized Steel Strip Or Wire Armoured, Electric Power Cables ( Heavy Duty ) 1100 Volts Grade With Stranded Aluminium Conductor Of Size 16 Sqmm 4.0 Coreincluding Testing Complete All As Specified And Directed. 36 All As Per Item Ser No 35.00 Above But Of Cable 35 Sqmm 3.5 Core 37 All As Per Item Ser No 35.00 Above But Of Cable 70 Sqmm 3.5 Core 38 All As Per Item Ser No 35.00 Above But Of Cable 120 Sqmm 3.5 Core 39 All As Per Item Ser No 35.00 Above But Of Cable 185 Sqmm 3.5 Core 40 All As Per Item Ser No 35.00 Above But Of Cable 300 Sqmm 3.5 Core 41 All As Per Item Ser No 35.00 Above But Of Cable 400 Sqmm 3.5 Core 42 Excavation In Trenches In Soft / Loose Soil Not Exceeding 1.5M Wide And Not Exceeding 1.5M In Depth Over Energised Lt Cables For Carrying Out Brick Work For Preparation Of Cable Duct Including For Taking Out And Relaying Of Lt Cables, Road Cutting Etc Complete All As Specified And Directed. 43 All As Per Item Ser No 41.00 Above But In Hard / Dense Soil. 44 Returning Filling In Including Spreading Levelling Watering And Well Ramming In Layers Not Exceeding 25Cm Thick In Soft / Loose Soil Complete All As Specified And Directed. 45 Removing Surplus Soil To A Distance Not Exceeding 50 Mtr And Depositing Where Directed At A Level And Not Exceeding 1.5 Mtr Above The Starting Point Complete All As Specified Anddirected. 46 Supply & Laying Dry Fine Sand For Cushioning Of Underground Cable Laid In Trenches / Duct Complete All As Specified And Directed.Note : Punned Thickness Of Sand Cushioning Shall Be Measured. 47 M&L For Sub Class B Burnt Brick Flat Across The Cable, For Protection Of Cable Laid In Trenches Complete All As Specified And Directed. 48 Labour Only For Relaying Of Serviceable Sub Class B Burnt Brick Flat Across The Cable, For Protection Of Cable Laid In Trenches Complete All As Specified And Directed.Note: Old Serviceable Bricks Retrived Shall To Reused. 49 M&L For Boring Of Holes Under Road, Pavement, Hard Standing By Trenchless Techonology Using Ultra Sound Technique And Necessary Machine Including Supply And Laying Of Gi Pipe Of 100 Mm Dia Light Grade Complete All As Specified And Directed. 50 Supply And Laying In Replacement Of Gi Pipe Medium Grade 150Mm Dia Laid In Trenches For Protection Of Ug Cable Complete All As Specified And Directed. 51 Supply And Laying In Replacement Ofgi Pipe Medium Grade 100Mm Dia Laid In Trenches For Protection Of Ug Cable Complete All As Specified And Directed. 52 Supply And Laying In Replacement Of Gi Pipe Medium Grade 50Mm Dia Laid In Trenches For Protection Of Ug Cable Complete All As Specified And Directed. 53 Supply And Erection Of Steel Tubular Swaged Poles Complete With Cast Iron Base Plate, Finial Taper Plug, Bolts, Nuts & Screws As Specified Type 410 Sp-3109 Mtr Metres Long. Poles Shall Be Coated With Two Coats Of Black Bituminous Paint Throughout Internally, And Externally Up To The Planting Depth.The Remaining Portion Of The Exterior Shall Be Painted With One Coat Of Red Oxide Primer Including Taking Down Old Unserviceable Pole Complete All As Specified And Directed. 54 S&F In Replacement Junction Box Smc Kiosk Box Water Proof Ip-54 Of Size 140X140x95mm Including Fixing Of Terminal Connector 100A 4 Pole Suitable For In And Out Connection Of 3 Core 2.5Sqmm Cable Fixed To Termination Box To Ligt Fittings Complete All As Specified And Directed. 55 M&L For Wiring With Multistranded Copper Conductor Of Size 2.5 Sqmm 3 Core Frlsh Matching With Existing Size / Type Including Proper Laying With The Help Of Locking Device Including Taking Down Old Unserviceable Complete All As Specified And Directed. 56 M&L For Pcc 1:2:4 Type B-1 ( Using 20 Mm Graded Stone Aggregate ) For Lt Pole Coping Etc Including Filling In Road Cuts / Hard Standing Etc Complete All As Specified And Directed. 57 M&L For Pcc 1:3:6 Type C-1 ( Using 20 Mm Graded Stone Aggregate ) For Lt Pole Foundation Etc Including Filling In Road Cuts / Hard Standing Etc Complete All As Specified And Directed. 58 M&L For Pcc 1:4:8 Type D-2 ( Using 40 Mm Graded Stone Aggregate ) For Lt Pole Foundation Complete All As Specified And Directed. 59 Material And Labour For Earthing Complete With Steel Earth Plate Electrode 600Mmx600mmx6mm Thick Burried In Ground Vertically To A Depth Not Less Than 2.25Meters Below Ground Level With Top Edge Of The Earth Plate At A Depth Not Less Than 1.5 Meter Below The Ground Level, Earth Plate Surrounded 15Cm Thick Layers Of Common Salt And Charcoal Dust Starting From Ground Below 15 Cm Of Earth Plate And Up To 15 Cm Above The Same.Gi Plate Connected With Galvanised Iron Strip Of 25X4 Mmby Means Of Copper Nuts, Bolts And Washers.Strip Shall Be Laid In 40Mm Dia Light Grade Gi Pipe As Protection From Top Of The Plate Up To Test Point ( Cost Of Protection Pipe Up To 7.5 Meters From Earth Electrode Will Be Included In The Rates Quoted By The Contractor ) With Following Complete Including Taking Out Old Unserviceable Earthing All As Specified And Shown In Electrical Plate No 3 Of Ssr Part-I & Testing On Completion :- ( A ) Gi Strip Of Size 25Mm X 4Mm. ( B ) Watering Pipe Gi Light Grade 20Mm Dia From Top Of The Earth Electrode Up To Ms Funnel With Wire Mesh Embeded In Floor Of Pcc Earth Pit. ( Gi Funnel Should Properly Be Tightened On Gi Watering Pipe And Embeded In Pcc Earth Pit With Open Top Suitable For Watering Of Earth Pits ) ( C ) Excavation & Earthwork In Any Type Of Soil Pcc Earth Pit 30X30x30cm Constructed In Pcc 1:2:4 Type B1 Exposed Surfaces Smoothly Finished With 15Mm Thick Cement Mortar 1:6 Including Rcc Pit Cover 50Mm Thick 1:2:4 Type B1 Reinforced With 8Mm Dia Mild Steel Tmt Bar 75Mm Centre To Centre With 2 Nos Ms Handles Of 12Mm Dia Mild Steel Tmt Bars Suitable For Carrying Of Pit Cover. 60 M&L For Earth Continuity Conductor Passing Through & Including Pvc Conduit Of Size 40Mmmain Earthing Lead Fixed To Wall On Batten Or Recess Or Chases Or Burried In Ground Or Drawn In Conduit / Pipe Or Any Other Indicated Situation For Loop Earthing Etc As Required 25X4 Mm Galvanised Iron Strip Complete All As Specified And Directed. 61 Disconnecting Of Electric Supply And Servicing Of Any Make And Type Of Apfc Panel And Its Minor / Major Parts By Cleaning, Checking And All Setting Of Relays, Contactor, Removing Dust Particle From The Panel, Checking Spring Mechanism, Tightening Of All Nut & Bolts Of Entire Panel And Checking All Control Wiring Of Entire System As Directed Testing On Load Complete All As Specifed And Directed. 62 S&Fin Replacement Of Apfc Relay For 10 Kvar, 10 Stagescomplete All As Specified And Directed. 63 S&F In Replacement Of A / M Switch Complete All As Specified And Directed Make :- Cat Part No 61025 Of L&T Or Equivalent As Approved By Ge. 64 S&F In Repleacement Of Led Type Indicatinglamp Type Of Voltage Ac / Dc Set Of Ryb, As Per Matching To Existing Complete All As Specified And Directed. Make:- L&T Or Equivalent As Approved By Ge. 65 S&F In Replacement Of Capacitor Bank Mpp-H, 05 Kvar Capacity Rated 440 Volts Ac, 3Ø, 50Hz , Delta Connection, Round Type Complete All As Specified And Directed. Make :- L&T Or Equivalent As Approved By Ge. 66 S&F In Replacement Of Capacitor Bank Mpp-H, 10 Kvar Capacity Rated 440 Volts Ac, 3Ø, 50Hz , Delta Connection, Round Type Complete All As Specified And Directed. Make:- L&T Or Equivalent As Approved By Ge. 67 S&F In Replacement Of Capacitor Duty, Contactor Mo C5 Complete All As Specified And Directed. Make:- L&T Or Equivalent As Approved By Ge. 68 S&F In Replacement Of Capacitor Duty, Contactor Mo C 12.5 Complete All As Specified And Directed. Make:- L&T Or Equivalent As Approved By Ge. 69 S&F In Replacement Of Capacitor Duty, Contactor Mo C 25 Complete All As Specified And Directed. Make:- L&T Or Equivalent As Approved By Ge. 70 S&F In Replacement Of Capacitor Duty, Contactor Mo C 50 Complete All As Specified And Directed. Make:- L&T Or Equivalent As Approved By Ge. 71 Supply, Installation, Testing & Commissioning Of Outdoor Floor Mounted Cubical Type Lt Panelsize Suitable To Accommodate Accessories For 415 V, 3 Phase, 4 Wire 50 Hz Ac Supply System Having Front Operated, Fabricated In Compartmentalized Design From Crca Sheet Steel Of 2 Mm Thick For Framework And Covers, 3 Mm Thick For Gland Plates I / C Cleaning & Finishing Complete With 7 Tank Process For Powder Coating In Approved Shade, Having Ip-42 Degree Of Protection With Hinged Lockable Doors, Dust And Vermin Proof Cpri Approved Ip-54And1500 Amp Capacity Extensiblealuminium Bus Bars Of High Conductivity For Three Phase Supply, Dmc / Smc Bus Bar Supports, Bottom Base Channel Of Ms Section Not Less Than 100 Mm X 50 Mm X 5 Mm Thick, Entire Panel Shall Have A Common Copper Earth Bar Of Size 25 Mm X 5 Mm At The Rear With 2 Nos. Earth Stud, And Control Wiring With 1.5 Sq. Mm. Name Plate For Each Switch Gears, Danger Plate Pvc Insulated Copper Conductor Standard Connector Cable, Cable Alleys, Cable Gland Plates In Two Half, Comprising Withand Accommodating The Following Switchgears & Accessories.:- ( A ) Acb 4 Pole 1250 Amps With Thermal Megnetic Release Fixed Type-01No ( B ) Mccb 400 Amps 4 Pole 36 Ka Repturung Capacity-04 Nos ( C ) Mccb 200 Amps 25 Ka 4 Pole - 03 Nos ( D ) Mccb 100 Amos 4 Pole 16 Ka : 02 Nos ( E ) Timmer Complete With Contactor And All Accessories 20 Amps 415V: 01 No 72 S&F In Repair Aluminium Thimble Of Size 35 Sqmm For Terminal End Of Cable Complete All As Specified And Directed. 73 S&F In Repair Aluminium Thimble Of Size 50 Sqmm For Terminal End Of Cable Complete All As Specified And Directed. 74 S&F In Repair Aluminium Thimble Of Size 70 Sqmm For Terminal End Of Cable Complete All As Specified And Directed. 75 S&F In Repair Aluminium Thimble Of Size 95 Sqmm For Terminal End Of Cable Complete All As Specified And Directed. 76 S&F In Repair Aluminium Thimble Of Size 120 Sqmm For Terminal End Of Cable Complete All As Specified And Directed. 77 S&F In Repair Aluminium Thimble Of Size 150 Sqmm For Terminal End Of Cable Complete All As Specified And Directed. 78 S&F In Repair Aluminium Thimble Of Size 185 Sqmm For Terminal End Of Cable Complete All As Specified And Directed. 79 S&F In Repair Aluminium Thimble Of Size 240 Sqmm For Terminal End Of Cable Complete All As Specified And Directed. 80 S&F In Repair Aluminium Thimble Of Size 300 Sqmm For Terminal End Of Cable Complete All As Specified And Directed. 81 S&F In Repair Aluminium Thimble Of Size 400 Sqmm For Terminal End Of Cable Complete All As Specified And Directed. 82 Supply And Fix Earth Pit Chamber Alongwith Cover Of Polymer, Frp Pit Cover Of Heavy High Grade Polypropelene For High Stress And Starin Level Of Size 225X300x 195 Mm Complete All As Specified And Directed. 83 Supply And Laying In Replacementgi Pipe Medium Grade Of 40Mm Dia Laid In Trenches For Protection Of Ug Cable Complete All As Specified And Directed. 84 S&F In Repair Stop Valves, Of Size 20Mm Cast Copper Alloy, Screwed Down, High Pressure, With Crutch Or Butterfly Handle, Screwed Both Ends For Iron Pipe Or For Unions And Fixed Complete All As Specified And Directed. 85 M&L For Dismantling Of Outdoor Unit Covers Of Vrf / Vrv Units Of Any Capacity Completely By Disconnecting / Covering All Electrical / Electronic Boards And Wiring And Serviceing Condensor Coil Completelt Wet Servicing By Using Chemical Approved By Oem And Replace All Defective / Unserviceable Parts Of Units Through Oem Of M / S Daikin. Reassembling And Setting All Parameters By Using Sofewares By An Oem Engineer ( M / S Daikin ) Complete All As Specified And Directed. 86 Dismantling Of Any Types Of Indoor Unit Covers Of Vrv / Vrf Unit Of Any Capacity Completely By Disconnecting / Covering All Electronic Boards And Wiring And Servicing Cooling Coils, Expansion Valves, Indoor Refrigerant Pipe Lines, Indoor Drainage Pumps, Drainage Lines Completely Wet Servicng By Using Approved Chemicals And Replace All Defective / Unserviceable Parts Of Units By Oem ( Make: Daikin ) By Using Tray Jackets Including Cleaning The Surface After Servicing Testing Complete All As Specified And Directed. ( I ) Out Door Units ( Make: Daikin ) Of Capacity Mentioned Below:- ( A ) Total Number Of Outdoor Unit- 26 No And Total Capacity Of Outdoor Units- 338Hp. ( 13X14hp+13X12hp ) . ( Ii ) Indoor Units ( Make:Daikin ) Of Capacity Mentioned Below:- ( Total 54 Units ) ( A ) Cassette 3 Tr : 07 Nos ( B ) Ductable 8.50Tr : 5 Nos. ( C ) 6.0 Tr Ductable : 38 Nos ( D ) Split Ac 1.5 Tr : 4 Nos. ( Iii ) Remote Controlsnote- The Repair / Maintanance Of Vrf / Vrv Plant Shall Be Done Through Oem I.E, M / S Daikin Only. 87 S&F In Replacement Of Four-Way Reverse Valve Complete All As Specified And Directed. 88 S&F In Replacement Of Inverter Pcb For Vrf System 14Hp / 12Hp As Per Existing Oem Complete All As Specified And Directed. 89 S&F In Replacement Of Control Pcb For Vrf System 14Hp / 12Hp As Per Existing Oem Complete All As Specified And Directed. 90 S&F In Replacement Of Power Transistor For Vrf System 14Hp / 12Hp As Per Existing Oem Complete All As Specified And Directed. 91 S&F In Replacement Of Divort Module For Vrf System 14Hp / 12Hp As Per Existing Oem Complete All As Specified And Directed. 92 M&L For Repair To Old Indoor Pcb For Vrf System 14Hp / 12Hp As Per Existing Oem Complete All As Specified And Directed. 93 S&F And Testing In Replacement Of Indoor Pcb For Vrf System 14Hp / 12Hp As Per Existing Oem Complete All As Specified And Directed. 94 Supply And Charging The Refrigerant R-410A For Vrf System 14Hp / 12Hp As Per Existing Oem Including Pressure Testing With Application Of Nitrogen Gas To Find Out Any Leakage, Brazing And Stopping Of All Leakage Detected, Re-Application Of Nitrogen Pressure To Ensure Leak Proof Gas Circular System And Flushing Out The Nitrogen Gas Complete All As Specified And Directed. 95 Supply, Fixing And Testing In Replacement Of Indoor Unit & Outdoor Unit Sensor For Vrf System 14 Hp / 12 Hp As Per Exisiting Oem Complete All As Specified And Directed. 96 Supply, Installation And Testing In Replacement Of Hermitically Sealed Scroll Compressor 7 Hp Three Phase For 14 Hp Vrf System As Per Existing Oem Complete All As Specified And Directed. 97 Supply, Installation And Testing In Replacement Of Hermitically Sealed Scroll Compressor 12 Hp Three Phase For 12 Hp Vrf System As Per Existing Oem Complete All As Specified And Directed. 98 M&L For Proctective / Anti Epoxy Coating After Chemical Wash The Vrf Outdoor Unit To Remove Carbon, Rust And To Minimise The Air Conditioners Gas Leak Problems From Pipes / Brazing Joints, Cooling Coils, Or All Unprotected Copper Pipes From Weather / Environmental Effect / Prolonged Corroded Condition And Also To Improve Their Life Span And Further Protect From Corrosion By Applying Single Step Coat Of Automotive Solution Or Copper Preventive Coat Or Any Other Equivalent Solution Isi Marked And Approved By Oem By Spray Coating Machine In All Outer Door Unit Of Vrv System13x14 Hp And 13X12 Hp And Their Connected Indoor Units All Types Under A Skilled / Qualified SupervisorS Supervision Complete All As Specified And Directed.

Corrigendum Details

Sr No CorrigendumDate Corrignedum CorrigendumType NewSubmissionDate
1 18-08-2023 Corrigendum02 Other 28-08-2023
2 28-08-2023 Bid Auto Extn Corrigendum Bid Auto Extn Corrigendum 04-09-2023

Key Value

Document Fees
INR 500 /-
EMD
INR 99900.0 /-
Tender Value
Refer document