| 1 | Each work in excavation by mechanicl means (Hydraulic excavator) / manual means over areas (exceeding 30 cm in depth, 1.5 m in width as well as 10 sqm on plan) including geting out and disposal of excavated earh lead up to 50 m and lif up to 1.5 m, as direced by Engineer-in-charge.All kinds of soil |
| 2 | Reinforced cement concrete work in beams, suspended floors, cum roofs having slope up to 15° landings, balconies, shelves, chajjas, lintels, bands, plain window sills, staircases and spiral stair cases above plinth level up to floor four level, excluding the cost of centering, shuttering, finishing and reinforcement with 1: 1.5:3 (1 cement : 1.5 coarse sand(zone-111) : 3 graded stone aggregate 20 mm nominal size). |
| 3 | Brick work with common burnt clay non-modular bricks of class designation 7 .5 in superstructure above plinth level up to floor IV level in all shapes and sizes in :Cement mortar 1:6 (1 cement: 6 coarse sand) |
| 4 | Rate for external plaster are for height upto 10m from groudn & IMIM cement plaster rates for external plaster are for height upto 10m from ground & IMIM cement plaseter1 :4 (1 cement: 4 fine sand |
| 5 | SAFETY ITEMSSupply and erection of Medium Voltage caution notice plate of size 200*150 mm in three languages. |
| 6 | Supply and erection of High Tension Voltage caution notice plate of size 250*200 mm in three languages. |
| 7 | EARTHING AND LIGHTENING ARRESTOREarthing with G.I. earth pipe 4.5 m long and 40 mm dia with masonry enclosures on the top etc. (but without charcoal or coke and salt) as required. |
| 8 | Extra for using salt and char coal/coke for pipe earth electrode as required. |
| 9 | Supplying and laying 25mm x 3 mm G.I. strip in 40 mm dia,GI pipe as/from earth electrode including soldering etc. as required. |
| 10 | Providing and fixing 25 mm x 3mm G.I. strip on surface or in recess for connections etc. as required with all labour and material. |
| 11 | Supply and erection of straight through joint (cable jointing kit) 1.1 KV grade complete with required quantity of resin, hardner, plastic mould G.P. Putty, adhesive, earth continuity, connections and fixing the same in postion complete with joint etc. - Straight through Joint.For 185 sqmm Cable 300 sqmm cable 3 to4 Core |
| 12 | Supplying and making outdoor cable end termination with heat shrinkable jointing kit complete with all accessories including lugs suitable for following size of 3 core, XLPE aluminium conductor cable of 11 KV grade as required :70 to 120 sqmm |
| 13 | Supply & erection of lighting arrestor modelALPRO / Alastem / LEMCO make suitable for 11KV 3 Phase 50 HZ ground neutral system comprising of spare gape type queen gap type in series with non linger resitar element house in Horizontally scale poreclam bushing with line and ground terminal along with mounting clamps conforming to ISS 3070 (Part-I) of 1985 with latest amendment with all labour and material required to the complete in all respect up to entire satisfaction of the Engineer-in-Charge of the works. |
| 14 | Supply & erection of 11KV gang operated switch Rashtriya / Jayshree / BHEL make conforming to IS with latest amendment including suitable size of copper blade erection of same on the existing \"H\"pole with the help of 3 Nos. channels of size 75mmx40mmx6mm, 1.8M long fixed with suitable size of MS clamp, nuts and bolts including cost of 6 Nos. 11KV insulator with GI pin, RD fuses and painting with 2 coat of approved paint and one coat of red oxide material required to complete the job in all respect up to entire satisfaction of the Engineer-in-Charge of the works. (Make and specification as per UHBVNL/DHBVNL) |
| 15 | Supply and erection of stay set with stay wire suitable for 11 M longPCC pole made out of 7/3 SWG GI wire with U type M.S. Rod 5/8\" dia duly threaded by means of angle iron of size 50 x 50 x 6 mm x 30 cm 6 feet long M.S. Rod buried in ground after fixing with cross channel size 75 x 40 x 6 mm x 60 cm long the stay wire will be binded on the top of the pole with help of suitable size of double U type M.S. Clamps and stay fixed with nuts and bolts the stay wire shall be insulated in the middle point with the help of egg insulator including all labour and material required to complete the job in all respect to the entire satisfaction of Engineer-in-charge of work. |
| 16 | Supply & Erection of rubber mat of size 1Mx2 M X 12mm thick suitable for 11 KV ISI marked complete in all respect upto the entire satisfaction of the engineer In-charge of the work. |
| 17 | Supply of Disc insulator Rashtriya / Jayshree / BHEL make with Disc fitting T&C type complete in all respect with erection of the same upto the entire satisfaction of the Engineer in Charge of work (Make and specification as per UHBVNL/DHBVNL) |
| 18 | S/E of M.S. chanel, MS angle, MS flat & nuts & bolts of required size including painting and cutting etc. with labour and material required to complete the job including fixing the same on existing pole complete in all respect |
| 19 | Supply & erection of fire extinguisher ISI marked Co 2 type 4.5 Kg. Capacity as Per ISI 7285 duly erected on wall with hook including the cost of hook, screw etc. with all the labour and material required to complete the job in all respect upto the entire satisfaction of the Engineer In charge of the work. Make: Ajay, Zenith, Minimax. |
| 20 | Supply and erection ofprestressed cement concrete pole as per IS : 1678-1960. 11 metres long 152 mm x 203 mm at top and 152 mm x 368 mm at bottom with working load of 360 Kg. burried 2.20 m in ground. (Make and specification as per UHBVNL/DHBVNL) including Erection of RCC/ PCC pole of following length in brick ballast and ramming the foundation, finishing with 150mm thick cement concrete (1 :3:6) layer on top with including excavation and refilling etc as required (As per HSR 24.4.10.4.)Above 8.0 metre and up to 11.0 metre. |
| 21 | Supply and erection of XLPE 11 or 33 kv HT aluminium conductor armoured cable ISI mark laid on surface/pipe/cable tray with all labour and material as required complete with necessary connections complete in all respect upto the entire satisfaction of Engineer in charge of the work 50 Sq. mm 3 Core Cable . |
| 22 | Supply and erection of RRC drain cover on existing trench having dimension of 914 mm x 610 mm x 30 mm with loading capacity of 500 Kg. complete with all labour and material as required to complete the job in all respect upto the entire satisfaction of Engineer in charge of the work |
| 23 | Supply and erection of G.I. chain link fencing (4 mm thickness G.I. wire) complete with all labour and material as required to complete the job in all respect upto the entire satisfaction of Engineer in charge of the work |