Sales : +91-777 804 8217
| Sl. No. | Item Description |
| 1 | Construction of Ramp for Additional Ward Block |
| 2 | EARTH WORKS: |
| 3 | Earth work in excavation by mechanical means (Hydraulic Excavator)/ manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan) including dressing of sides and ramming of bottoms, lift upto 1.5 m. including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50m. |
| 4 | All kinds of soil |
| 5 | Filling available excavated earth (excluding rock) in trenches. plinth, sides of foundations etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift upto 1.5 m. |
| 6 | Supplying and filling in plinth with sandy soil under floors including watering, ramming, consolidating & dressing complete. |
| 7 | Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering -All work upto plinth level: |
| 8 | 1:4:8(1 Cement:4 coarse sand:8 graded stone aggregate: 40 mm nominal size). |
| 9 | Providing and laying in position specified grade of reinforced cement concrete, excluding the cost of centering, shuttering, finishing and reinforcement - All work upto plinth level |
| 10 | 1:1.5:3 (1 cement : 1.5 coarse sand : 3 graded stone aggregate 20 mm nominal size) |
| 11 | Reinforced cement concrete work in walls (any thickness), including attached pilasters, buttresses, plinth and string courses, fillets, columns, pillars, piers, abutments, posts and struts etc. above plinth level up to floor five level, excluding cost of centering, shuttering, finishing and reinforcement : |
| 12 | 1:1.5:3 (1 cement :1.5 coarse sand :3graded stone aggregate 20 mm nominal size) |
| 13 | R.C.C. work in beams, suspended floors, roofs having slope uptp 15o landings, balconies, shelves, chajjas,lintels, band, plain window sills, staircases and spiral staircases above plinth level upto floor fivelevel excluding the cost of centering, shuttering, finishing and reinforcement, with 1 : 1 .5: 3 (1 cement :1.5 coarse sand :3 graded stone aggregate 20 mm nominal size) |
| 14 | Reinforcement for R.C.C work including straightening, cutting, bending, placing in position and binding all complete. Above Plinth Level. |
| 15 | Thermo-Mechanically Treated bars |
| 16 | Centering and shuttering including strutting, propping etc. and removal of form for: |
| 17 | Foundations, footings, bases of columns, etc. for mass concrete |
| 18 | Lintels, beams, plinth beams, girders, bressumers and cantilevers. |
| 19 | Columns, pillars, piers, abutments, posts and struts. |
| 20 | Suspended floors, roofs, landings, balconies and access platform |
| 21 | BRICK WORKS: |
| 22 | Brick work with 1st class common burnt clay F.P.S. (non modular) bricks in foundation and plinth in: |
| 23 | Cement mortar 1:4 (1 cement : 4 coarse sand) |
| 24 | Half brick masonry with 1st class common burnt clay F.P.S. (non modular) bricks in superstructure above plinth level upto floor V level in |
| 25 | Cement mortar 1:3 (1cement:3coarse sand) |
| 26 | Providing aluminium works for door windows ventilators and partitions with extruded built up standard tubular sections/appropriate Z sections and other sections of approved make conforming to !S:733 and IS :1285 fixed with rawl plug and screws or with fioxing clamp or with expansion hold fastner including necessary filling up gaps at junctions at top bottom & side with required EPDM rubber/neoprene gasket etc. Aluminium snap beading for glazing panelling CP brass/stainless screws all complete as per architectural dwg and direction of the engineer incharge (Glazing and panelling to be paid seperately) |
| 27 | Anodised aluminium (anodised transparent or dyed to required shade according to IS 1868 minimum anodic coating of grade AC 15).s |
| 28 | Providing and fixing glazing in aluminium door, window. ventilator shutters and partitions etc. with EPDM rubber/neoprene gasket etc. complete as per the architectural drawings and the directions of engineer-in-chargo . (Cost of aluminium snap beading shall be paid in basic item): |
| 29 | With float glass panes of 4.0 mm thickness |
| 30 | FLOORING WORK |
| 31 | Providing and laying Vitrified tiles in floor in diffe rent sizes (thickness to be specified by the manufacturer) with water absorption less than 0.080/0 and conforming to 19.15622, of approved brand & manufacturer, in all colours and shade, laid on 20 mm thick cement mortar 1:4 (1 cement: 4 coarse sand) jointing with grey cement slurry @3.3 kg/sqm including grouting the joints with white cement and matching pigments etc. The tiles must be cut with the zero chipping diamond cutter only . Laying of tiles will bo done with the notch trowel, plier, wedge, clips of required thickness, leveling system and rubber mallet for placing the tiles gently and easily. |
| 32 | Double charge vitrified tile polished finish of size |
| 33 | Size of Tile 600x600 mm |
| 34 | Kota Stone slab flooring over 20mm( Average ) thick base laid over and jointed with grey cement slurry mixed with pigment to match shade of the slab including rubbing and polishing complete with base of cement Motar 1: 4 ( I cement : 4 Coarse sand ). |
| 35 | 25mm thick |
| 36 | Kota Stone slab 25mm thick in riser of step, skirting dado, and pillar laid on 12mm( Average) thickcement Motar 1: 3 ( I cement : 3 Coarse sand )and jointed with grey cement slurry mixed with pigment to match shade of the slab including rubbing and polishing complete. |
| 37 | STEEL WORK |
| 38 | Providing andfixing in position collapsible steel shutter wit vertical channels 20x10x2mm and braced with iron digonals 20 x5mm size with topp and bottom rail o T- iron 40x40x mmwit 40mm dia., steel pully s complete with bolts nuts, locking arrangement, stoppers handles including a priming coat of approve steel primer. |
| 39 | Providing and fixing stainless steel ( Grade 304) railing made of Hollow tubes, channels, plates etc., including welding, grinding, buffinge polishing and making curvature (wherever required) and fittingn the same with necessary stainless steel nuts and bolts complete, i/c fixing the railing with necessary accessories & stainless steel dash fasteners , stainless steel bolts etc., of required size, on the top of the floor or the side of waist slab with suitable arrangement as per approval of Engineer-in-charge, (for payment purpose only weight of stainless steel members shall be considered excluding fixing accessories such as nuts, bolts, fasteners etc.). the same with necessary stainless steel nuts and bolts complete, i/c fixing the railing with necessary accessories & stainless steel dash fasteners , stainless steel bolts etc., of required size, on the top of the floor or the side of waist slab with suitable arrangement as per approval of Engineer-in-charge, (for payment purpose only weight of stainless steel members shall be considered excluding fixing accessories such as nuts, bolts, fasteners etc.). |
| 40 | FINISHING: |
| 41 | 15 mm cement plaster on rough side of single or half brick wall finished with a floating coat of neat cement of mix : |
| 42 | 1:3 (1 cement: 3 fine sand) |
| 43 | Distempering with oil bound washable distemper of approved brand and manufacture to give an even shade:- |
| 44 | New work (Two or more coat ) over and including priming coat with cement primer |
| 45 | Finishing walls with textured exterior paint of required shade: |
| 46 | New work (Two or more coat applied @ 3.28 ltr/10 sqm over and including base coat of water proofing cement paint applied @ 2.20 kg/10 sqm) |
| 47 | Providing and applying white cement based putty of average thickness 1mm,of approved brand and manufacturer, over the plasterod wall surface to prepare the surface even and smooth complete. |
| 48 | Providing and fixing on wall face unplasticied ridgid PVC rain water pipe conforming to IS : 13592 typea A including oining wuith sealed ring confirming to Ius 5382 leaving 10mm gap for thermal expansion (i)Single socked ed pipes |
| 49 | 75mm diameter |
| 50 | Making plinth protection 50 mm thick of cement concrete 1:3:6 ( 1 cement: 3 coarse sand : 6 graded stone aggregate 20 mm nominal size) over 75 mm bed of dry brick ballast 40 mm nominal size well rammed and consolidated and grouded with fine sand including finishing the top smooth. |
| 51 | Sub-Head -I (Wiring) |
| 52 | Wiring for light point / fan point/Exhaush Fan point /call bell point with 1.5 sq.mm FR PVC insulated copper conductor single core cable in surface /recessed steel conduit with modular type switch,phemolic laminated sheet suitable size M.S. box and earthing the point with 1.5 sq.mm FR PVC insulated copper conductor single core cable etc as required. |
| 53 | Group A |
| 54 | Wiring for circuit / sub main wiring alongwith earth wire with following size of FR PVC insulated copper conductor, single core cable in surface /recessed steel conduit as required. |
| 55 | (b) 2X2.5.mm² +1x2.5mm² |
| 56 | Sub- Head-II |
| 57 | ( Fittings & Accessories) |
| 58 | S/F Recess Mounting LED down Lighter BGSL 0601WH,220227,cast aluminium housing fixed with collimated lens,6x1W white LED mounted on MCPCB ,extruded Al heat sink spring loaded mounting clips, complete with connections etc as reqd. |
| 59 | Supply and fixing of following size of PVC casing and capping along with accessories etc. |
| 60 | (a) 25mm |
| 61 | Single Piece cast Al. with full glass cover integral lumineries (ip66) HPSv-150W grey powder coated dia-cast Al.housing complete with all accessories. (BGEST-250 SV FG SHN WOB/BJOS 250 SV/MH) (C188507/168797). |
| 62 | ERECTION OF STEEL TUBULAR POLES |
| 63 | Erection of steel tubular pole of length not less than 8mtrs but not exxceeding 10mtrs.in cement concrete 1:3:6 (1 cement : 3 coarse sand :6 graded stone agtt. 40mm nominal size) foundation i/c excavation & re-felling etc.as reqd |
| 64 | Sub-Head - IV |
| 65 | ( Earthing ) |
| 66 | Earthing with Copper earth plate 600mmx600mmx6mm thick i/c accessories, and providing masonary encloure with cover plate having locking arrangement and watering pipe etc.(but without charcoal or coke and salt ) as required. |
| 67 | Providing and fixing 8 SWG dai G wire on surface of in surface or in recess for loop earthing along with existing surface/recessed conduit/submain wiring /cable,as required. |
| 68 | Providing and fixing of lightning conductor finial made of 25 mm dia 300mm long copper tube having single prong at top with 85mm dia 3mm thick copper platemi/c holes etc. complete as reqd |
| 69 | Sub- Head- II |
| 70 | (DB,s & MCB,s) |
| 71 | S/F 6way, (2+6 way) single door single pole and neutral, prewired, sheet steel MCB distribution board, 240V on surfuce/ recessed complete with loose wire box, terminal blocks, tinned copper bus bar, neutral link, earth bar, din bar, detachable gland plate, interconnection, including powder coat painting, earthing etc as reqd. (but without MCB/RCCB/Isolator). |
| 72 | S/F \"B\" series,SP MCB. Supplying and fixing following 5 amps to 32 amps rating 240 Volts, B series, miniture circuit breaker suitable for lighting and other load of following poles in the existing MCB DB complete with connection, testing and commissioning etc as required. |
| 73 | (a) Double Pole |
| 74 | S/FDP MCBisolator: Supplying and fixing following rating, double pole,240 volts, isolator in the existing MCB DB complete with connection, testing and commissioning etc. as required. |
| 75 | (b) 100 amps. |
| 76 | METAL CLAD SFU WITH HRC FUSES & MCB\"S RCCB\"S |
| 77 | 32 amps TP & N-dis-connector fuse switch unit with HRC fuse |
| 78 | LAND DEVELOPMENT |
| 79 | Excavation in Hill Area in soil by Mechanical Means (Excavation in soil in hilly area by manual means including cutting and trimming of side slopes and disposing of excavated earth with all lifts and lead upto 1000 meters). |
| 80 | Construction of Vehicle Shed for District Hospital Ukhrul at Ukhrul. |
| 81 | EARTHWORK |
| 82 | Earth work in excavation in foundation trenches ordrainsi/c. dressing of sides and ramming of bottoms lift upto 1.5m including getting out the excavated soil anddisposalof surplusexcavated soil as directed,within a lead of50m in |
| 83 | a) All kind of soil |
| 84 | Fillingavailableexcavated earth(excludingrock) intrenches, pinth, sidesoffoundationsetc. in layers not exceeding 20 cm in depth, consolidation each deposited layer by rammingand watering, lead upto 50mand lift upto 1.5m. |
| 85 | Supplying and Filling in plinth with sandy soil under floors including watering ramming, consolidating and dressing complete. |
| 86 | CONCRETE WORK |
| 87 | Providing and laying cement concrete in foundation. Plinth excluding the cost of centering and shuttering with 1:5:10 ( 1 cement : 4 c/sand : 8 graded stone aggregate. 40mm. nominal size). |
| 88 | DAMP-PROOF COURSE |
| 89 | Providing and laying damp proof course 50mm thick with cement concrete1:2:4 ( 1 cement : 2 c/sand : 4 graded stone aggregate. 20mm. nominal size). |
| 90 | REINFORCED CEMENT CONCRETE WORK |
| 91 | Reinforced cement concrete work in beams, suspended floors, roofs having slope up to 15° landings, balconies, shelves, chajjas, lintels, bands, plain window sills, staircases and spiral stair cases above plinth level up to floor five level, excluding the cost of centering, shuttering, finishing and reinforcement, with ( a) 1:1.5:3 ( 1 cement : 1.5 coarse sand : 3 graded stone aggregate 20 mm nominal size) |
| 92 | Reinforced cement concrete work in walls (any thickness), including attached pilasters, buttresses, plinth and string courses, fillets, columns, pillars, piers, abutments, posts and struts etc. above plinth level up to floor five level, excluding cost of centering, shuttering, finishing and reinforcement : (a) 1:1.5:3 ( 1 cement : 1.5 coarse sand : 3 graded stone aggregate 20 mm nominal size) |
| 93 | STEEL REINFORCEMENT |
| 94 | Reinforcement for RCC work including Straightening, cutting, bending,placing in position and binding all complete. |
| 95 | (a) Thermo-Mechanically treated bars. |
| 96 | BRICK WORK |
| 97 | Brick work in 1st class common burnt clay F.P.S ( non modular ) bricks in foundation and plinth in : Cement motar 1:4 (1cement:4 coarse sand) |
| 98 | HALF BRICK WORK |
| 99 | Brick work 7cm thick with 1st class common burnt clay F.P.S ( non modular ) bricks incement motar 1:3 (1cement:3 coarse sand) in superstructure above plinth level and upto floor five level. |
| 100 | FORM WORK |
| 101 | Providing form work i/c shuttering and centering so as to give a rough finish, strutting and propping etc. height of propping and centering below supporting floor to ceiling not exceeding 4m. And removal of the same for in-situ reinforced concrete and plain concrete work in |
| 102 | b) Columns, Pillars, Piers, Abutments, Posts and Struts. |
| 103 | c) Lintels, beams, plinth beams, girders, bressumers and cantilevers. |
| 104 | TUBULAR TRUSSES |
| 105 | Steel work in built up tubular ( round, square or rectangular tubes etc.) including cutting, hoisting fixing in position and applying a priming coat of approved steel primer, including welding and bolted including special shaped washers etc. complete. |
| 106 | Electric resistance or induction butt welded tubes. |
| 107 | WOOD WORK |
| 108 | Providing wood works in frames of doors, windows, clerestory windows & other frames, wrought framed & fixed in position with hold fast lugs or with dash fastener of required dia and length ( hold fast lugs or dash fastener shall be paid for separately : |
| 109 | b) Local best quality Uningthou wood |
| 110 | Providing and fixing panelled or panelled andglazed shutters for doors, windows and clerestory windows including ISI marked M.S butt hinges bright finished of required size with necessary screws, excluding panelling which will be paid for separately, all complete as per direction of Engineering-in-charge. |
| 111 | Local best quality Tolhao wood35 mm thick shutters. |
| 112 | Providing 40x5 mm flat iron hold fast 40cm long including fixing to frame with 10 mm diameter bolts, nuts and wooden plugs and embedding in cement concrete block 30x10x15cm 1:3:6 mix ( 1 cement : 3 coarse sand : 6 graded stone aggrigate 20mm nominal size) |
| 113 | Providing and fixing bright finished steel 100 mm door mortice latch and apair of levers handles with necessary screws complete ( indian make of approved quality) |
| 114 | Providing and fixing ISI marked oxidised M.S tower bolt black finish, (Barrel type) with necessary screws etc. complete : |
| 115 | a) 200 x 10 mm |
| 116 | Providing and fixingISI marked M.S pressedbut hinges bright finished with necessary screws etc. complete : |
| 117 | 125x65x3mm |
| 118 | FLOORING |
| 119 | 75 mm thick cement concrete flooring with concrete hardener topping under layer 40 mm thick cement concrete 1:2:4 (1 cement: 2 coarse sand:4 stone aggregate 20 mm nominal size) and top layer 12mm thick cement hardener consisting of mix 1:2 (1 cement hardener mix : 2 graded stone aggregate 6 mm nominal size) by volume. hardening compound is mixed @ 2 litre per 50 kg of cement or as per manufacturers specifications. This includes cost of cement slurry, but excluding the cost of nosing of steps etc. complete. |
| 120 | PROFILE SHEET ROOFING |
| 121 | Trapzoidal Pre-painted Profile Sheet roofing of approved brand DYNA Roof or equivalent with selt drilling screws of 68 mm long Xylon coated screws with PVC washer & caps complete, excluding the coat of purlins & trusses. Pre- painted galvalume sheet (PPGL) |
| 122 | i) Profile sheet 0.50 mm/4.2 kgs/sqm |
| 123 | Trapzoidal Pre-painted Profile Sheet for RidgesGutter or Valley 610 mm wide of approved brand DYNA Roof or equivalent fixed with selt drilling screws of 68 mm long Xylon coated screws with PVC washer & caps completed, excluding the coat of purlins rafter & trusses. |
| 124 | i) Profile sheet 0.50 mm/4.2 kgs/sqm |
| 125 | FINISHING |
| 126 | Internall wall plaster 12mmthick Cement mortar 1 :4 ( 1 Cem : 4 c/sand) |
| 127 | External wall plaster 15 mm thick with cement mortar :1:4 (1 cement: 4 fine sand) |
| 128 | Providing and fixing on wallface unplasticised Rigid PVC rain water pipes conforming to IS: 13592 Type A including jointing with seal ring conforming to IS: 5382 leaving 10mm gap for thermal expansion, i) Single Socketed pipes |
| 129 | 75 mm diameter |
| 130 | Providing and fixing on wallface unplasticised Rigid PVC molded fittings accessories for unplasticised Rigid PVC rain water pipes conforming to IS: 13592 Type A including jointing with seal ring conforming to IS: 5382 leaving 10mm gap for thermal expansion |
| 131 | CEMENT PAINTING ORDINARY |
| 132 | Applying one coat of cement primer of approved quqlity on wall surface |
| 133 | Distemperingwith dry distemper of approved brand and manufacturer (two or more coats) and required shade on new work, over and including priming coat whiting to give an even shade :- |
| 134 | PRIMING COAT |
| 135 | Applying one coat of water thinnable cement primer of approved brand and manufacture on wall surface |
| 136 | SUPERIOR READY MIXED PAINT |
| 137 | Painting ( two or more coats ) with superior gloss enamael paint of any shade of approved quality on new steen work to give an even shade |
| 138 | SUPERIOR GLOSS ENAMELPAINT |
| 139 | Painting ( two or more coats ) with superior gloss enamael paint of any shade of approved quality on new steen work to give an even shade |
| 140 | PLASTIC EMULSIONPAINT |
| 141 | Painting ( two or more coats ) with superior gloss enamael paint of any shade of approved quality on new steen work to give an even shade |
| 142 | INTERNAL ELECTRIFICATION AND INSTALLATION |
| 143 | Sub-Head -I (Wiring) |
| 144 | Wiring for light point / fan point/Exhaush Fan point /call bell point with 1.5 sq.mm FR PVC insulated copper conductor single core cable in surface /recessed steel conduit with piano type switch,phemolic laminated sheet suitable size M.S. box and earthing the point with 1.5 sq.mm FR PVC insulated copper conductor single core cable etc as required. |
| 145 | Group A |
| 146 | Wiring for circuit / sub main wiring alongwith earth wire with following size of FR PVC insulated copper conductor, single core cable in surface /recessed steel conduit as required. |
| 147 | (a) 2X1.5.mm² +1x1.5mm² |
| 148 | (b) 2X2.5.mm² +1x2.5mm² |
| 149 | Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required. |
| 150 | (a) 5/6 A switch |
| 151 | Supplying and fixing following size/ modules, GI box alongwith modular base & cover plate for modular switches in recess etc. as required.. |
| 152 | (d) 12 Module (200mmX150mm) |
| 153 | Sub- Head-II |
| 154 | ( Fittings & Accessories) |
| 155 | S/F Vertical down lighters with LED 1x10/13 white powder coated CRCA ring, bright finished reflector i/c connection etc. (ref. 538536 BJDR 110/113 WEB/VI, D type CFL 1x10/13 W). |
| 156 | Single Piece cast Al. with full glass cover integral lumineries (ip66) HPSv-70W grey powder coated dia-cast Al.housing complete with all accessories. |
| 157 | ERECTION OF STEEL TUBULAR POLESes) |
| 158 | Erection of steel tubular pole of length not less than 8mtrs but not exxceeding 10mtrs.in cement concrete 1:3:6 (1 cement : 3 coarse sand :6 graded stone agtt. 40mm nominal size) foundation i/c excavation & re-felling etc.as reqd |
| 159 | Sub-Head - IV |
| 160 | ( Earthing ) |
| 161 | Earthing with Copper earth plate 600mmx600mmx6mm thick i/c accessories, and providing masonary encloure with cover plate having locking arrangement and watering pipe etc.(but without charcoal or coke and salt ) as required. |
| 162 | Providing and fixing 8 SWG dai G wire on surface of in surface or in recess for loop earthing along with existing surface/recessed conduit/submain wiring /cable,as required. |
| 163 | Sub- Head- II |
| 164 | (DB,s & MCB,s) |
| 165 | S/F 6way, (2+6 way) single door single pole and neutral, prewired, sheet steel MCB distribution board, 240V on surfuce/ recessed complete with loose wire box, terminal blocks, tinned copper bus bar, neutral link, earth bar, din bar, detachable gland plate, interconnection, including powder coat painting, earthing etc as reqd. (but without MCB/RCCB/Isolator). |
| 166 | S/F \"B\" series,SP MCB. Supplying and fixing following 5 amps to 32 amps rating 240 Volts, B series, miniture circuit breaker suitable for lighting and other load of following poles in the existing MCB DB complete with connection, testing and commissioning etc as required. |
| 167 | (a) Single Pole and neutral. |
| 168 | S/FDP MCBisolator: Supplying and fixing following rating, double pole,240 volts, isolator in the existing MCB DB complete with connection, testing and commissioning etc. as required. |
| 169 | (b) 100 amps. |
| 170 | METAL CLAD SFU WITH HRC FUSES & MCB\"S RCCB\"S |
| 171 | 32 amps TP & N-dis-connector fuse switch unit with HRC fuse |
| 172 | Construction of Kitchen |
| 173 | Earth work in excavation in foundation trenches ordrainsi/c. dressing of sides and ramming of bottoms lift upto 1.5m including getting out the excavated soil anddisposalof surplusexcavated soil as directed,within a lead of50m in Hard dense Soil |
| 174 | Fillingavailableexcavated earth(excludingrock) intrenches, pinth, sidesoffoundationsetc. in layers not exceeding 20 cm in depth, consolidation each deposited layer by rammingand watering, lead upto 50mand lift upto 1.5m. |
| 175 | Supplying and Filling in plinth with sandy soil under floors including watering ramming, consolidating and dressing complete. |
| 176 | Providing and laying cement concrete in foundation. Plinth excluding the cost of centering and shuttering with 1:5:10 ( 1 cement : 5 c/sand : 10 graded stone aggregate. 40mm. nominal size). |
| 177 | Providing and laying damp proof course 50mm thick with cement concrete1:2:4 ( 1 cement : 2 c/sand : 4 graded stone aggregate. 20mm. nominal size). |
| 178 | Reinforcement for RCC work including Straightening, cutting, bending,placing in position and binding all complete. |
| 179 | (a) Thermo-Mechanically treated bars. |
| 180 | Reinforced cement concrete work in beams, suspended floors, roofs having slope up to 15° landings, balconies, shelves, chajjas, lintels, bands, plain window sills, staircases and spiral stair cases above plinth level up to floor five level, excluding the cost of centering, shuttering, finishing and reinforcement, with ( a) 1:1.5:3 ( 1 cement : 1.5 coarse sand : 3 graded stone aggregate 20 mm nominal size) |
| 181 | Reinforced cement concrete work in walls (any thickness), including attached pilasters, buttresses, plinth and string courses, fillets, columns, pillars, piers, abutments, posts and struts etc. above plinth level up to floor five level, excluding cost of centering, shuttering, finishing and reinforcement : (a) 1:1.5:3 ( 1 cement : 1.5 coarse sand : 3 graded stone aggregate 20 mm nominal size) |
| 182 | Providing form work i/c shuttering and centering so as to give a rough finish, strutting and propping etc. height of propping and centering below supporting floor to ceiling not exceeding 4m. And removal of the same for in-situ reinforced concrete and plain concrete work in |
| 183 | b) Columns, Pillars, Piers, Abutments, Posts and Struts. |
| 184 | c) Lintels, beams, plinth beams, girders, bressumers and cantilevers. |
| 185 | Brick work in 1st class common burnt clay F.P.S ( non modular ) bricks in foundation and plinth in : Cement motar 1:4 (1cement:4 coarse sand) |
| 186 | Brick work 7cm thick with 1st class common burnt clay F.P.S ( non modular ) bricks incement motar 1:3 (1cement:3 coarse sand) in superstructure above plinth level and upto floor five level. |
| 187 | Providing wood works in frames of doors, windows, clerestory windows & other frames, wrought framed & fixed in position with hold fast lugs or with dash fastener of required dia and length ( hold fast lugs or dash fastener shall be paid for separately : |
| 188 | b) Local best quality Uningthou wood |
| 189 | Providing and fixing panelled or panelled andglazed shutters for doors, windows and clerestory windows including ISI marked M.S butt hinges bright finished of required size with necessary screws, excluding panelling which will be paid for separately, all complete as per direction of Engineering-in-charge. |
| 190 | Local best quality Tolhao wood35 mm thick shutters. |
| 191 | Providing 40x5 mm flat iron hold fast 40cm long including fixing to frame with 10 mm diameter bolts, nuts and wooden plugs and embedding in cement concrete block 30x10x15cm 1:3:6 mix ( 1 cement : 3 coarse sand : 6 graded stone aggrigate 20mm nominal size) |
| 192 | Providing and fixing ISI marked oxidised M.S sliding door bolts with screws etc. complete.300X16 mm |
| 193 | Providing and fixing ISI marked oxidised M.S tower bolt black finish, (Barrel type) with necessary screws etc. complete :250 X 10 mm |
| 194 | a) 250 x 10 mm |
| 195 | Providing and fixing oxidised M.S hasp and stable(safety type) conforming to IS: necessary screws etc. complete : |
| 196 | 100x75x3.50mm |
| 197 | Steel work in built up tubular ( round, square or rectangular tubes etc.) including cutting, hoisting fixing in position and applying a priming coat of approved steel primer, including welding and bolted including special shaped washers etc. complete. |
| 198 | Electric resistance or induction butt welded tubes. |
| 199 | Providing & fixing precoated galvanised iron profile sheets (size, shape and pitch of corrugation as approved by Engineer-in-Charge) with zinc caoting 120 grams per sqm as per IS:277, in 240 mpa steel grade, 5-7 microns epoxy primer on both side of the sheet and polyester top coat 15-18 microns. Sheet should have protective guard film of 25 microns minimum to avoid scratches during transportation and should be supplied in single length upto 12 metres or as desired by Engineers-in-charge. |
| 200 | Precoated galvanished iron profile sheets 0.50 mm thick . |
| 201 | Providing & fixing precoated galvanised steel roofing accessories, Zinc caoting 120 grams per sqm as per IS:277, in 240 mpa steel grade, 5-7 microns epoxy primer on both side of the sheet and polyester top coat 15-18 microns using self drilling/self tapping screws or with polymer coated J or L hooks, bolts and nuts and or GI seam bolts and nuts, G.I plain and bitumen washers complete : |
| 202 | Ridges plain (500 -600mm) |
| 203 | Precoated galvanished iron profile sheets 0.50 mm thick . |
| 204 | 52 mm thick cement concrete flooring with concrete hardener topping under layer 40 mm thick cement concrete 1:2:4 (1 cement: 2 coarse sand:4 stone aggregate 20 mm nominal size) and top layer 12mm thick cement hardener consisting of mix 1:2 (1 cement hardener mix : 2 graded stone aggregate 6 mm nominal size) by volume. hardening compound is mixed @ 2 litre per 50 kg of cement or as per manufacturers specifications. This includes cost of cement slurry, but excluding the cost of nosing of steps etc. complete. |
| 205 | 12mm Cement Plaster of mix 1 :4 ( 1 Cem : 4 c/sand) |
| 206 | 15 mm cement plaster on rough side of single or half brick wall finished with a floating coat of neat cement of mix : 1:3 (1 cement: 3 fine sand) |
| 207 | Providing and fixing on wallface unplasticised Rigid PVC rain water pipes conforming to IS: 13592 Type A including jointing with seal ring conforming to IS: 5382 leaving 10mm gap for thermal expansion, i) Single Socketed pipes |
| 208 | 75 mm diameter |
| 209 | Finishing walls with textured exterior paint of required shade :New work (two or more coat of water proofing cement paint applied @ 2.20 kg/10 sqm. |
| 210 | Applying priming coat :-with ready mixed pink or Grey primer of approved brand and manufacture on wood work (hard and soft wood ) |
| 211 | Providing and applying two coats of fire retardant paint unthinned on cleaned wood/ply surface @ 3.5 sqm per litre per coat including preparation of base surface as per recommendation of manufacturer to make the surface fire retardant. |
| 212 | Distemperingwith oil bound washable distemper of approved brand and manufacturer to give an even shadeNew work (two or more coats) over and including priming coat with cement primer :- |
| 213 | SH:- Water Supply & Sanitory Installation |
| 214 | Septic Tank |
| 215 | Earth work in excavation in foundation trenches ordrainsi/c. dressing of sides and ramming of bottoms lift upto 1.5m including getting out the excavated soil anddisposalof surplusexcavated soil as directed,within a lead of50m in Hard dense Soil |
| 216 | Fillingavailableexcavated earth(excludingrock) intrenches, pinth, sidesoffoundationsetc. in layers not exceeding 20 cm in depth, consolidation each deposited layer by rammingand watering, lead upto 50mand lift upto 1.5m. |
| 217 | Providing and laying cement concrete in foundation. Plinth excluding the cost of centering and shuttering in 1 : 4 : 8 ( 1 cement :4 c/sand : 8 graded stone aggregate. 40mm. nominal size). |
| 218 | Brick work in 1st class common burnt clay F.P.S ( non modular ) bricks in foundation and plinth in : Cement motar 1:4 (1cement:4 coarse sand) |
| 219 | Brick work 7cm thick with 1st class common burnt clay F.P.S ( non modular ) bricks incement motar 1:3 (1cement:3 coarse sand) in superstructure above plinth level and upto floor five level. |
| 220 | Reinforced cement concrete work in beams, suspended floors, roofs having slope up to 15° landings, balconies, shelves, chajjas, lintels, bands, plain window sills, staircases and spiral stair cases above plinth level up to floor five level, excluding the cost of centering, shuttering, finishing and reinforcement, with ( a) 1:1.5:3 ( 1 cement : 1.5 coarse sand : 3 graded stone aggregate 20 mm nominal size) |
| 221 | Reinforcement for RCC work including Straightening, cutting, bending,placing in position and binding all complete. |
| 222 | (a) Thermo-Mechanically treated bars. |
| 223 | Providing form work i/c shuttering and centering so as to give a rough finish, strutting and propping etc. height of propping and centering below supporting floor to ceiling not exceeding 4m. And removal of the same for in-situ reinforced concrete and plain concrete work in |
| 224 | d) Weather shade, chajjas , corbels etc. including edges. |
| 225 | 15 mm cement plaster on rough side of single or half brick wall finished with a floating coat of neat cement of mix : 1:3 (1 cement: 3 fine sand) |
| 226 | Providing and fixing UPVC soil, waste, rain water and vent pipes including all requisite fittings, jointing of pipes & fitting with solvent cement, tenching, refilling & testing of joints complete as per direction of Engineer in charge. |
| 227 | 75 mm dia |
| 228 | 110 mm dia |
| 229 | Supplying and fixing C.I. Cover with frame (for manhole and chambers) |
| 230 | 600x450 mm rectangular C.I. Cover (light duty) 23 kg |
| 231 | Providing and fixing 600x450 mm bovolod cdgo mirror of superior glass (Of approved quality) complete with 6 mm thick hard board ground fixed to wooden cleats with C.P. brass scrows and washers complete. |
| 232 | Providing and Fixing 600x20mm C.P brass towel rail complete with C.P brass brackets fixed to woodencleats with C.P brass screws (hook type) |
| 233 | Providing and fixing solid plastic seat with lid for pedestal type W.C. pan complete |
| 234 | White solid plasticseat with lid. |
| 235 | P/F white vitreous china wash basin i/c making all connections but excluding the cost of fittings |
| 236 | Flate back wash basin of size 450x300 mm |
| 237 | Providing and fixing white vitreous china pedestal type water closet (European type W.C. pan) with scat and lid, 10 litre low level white P.V.C. flushing cistern, including flush pipe, with manually controlled device (handle lever). conforming to IS : 7231. with all fittings and fixtures complete. including cutting and making good the walls and floors wherever required : |
| 238 | W.C. pan with ISI marked white solid plastic seat and lid |
| 239 | P/F 8mm dia C.P./SS Jet with flexible tube upto 1 metre long with triangular plate to European type W.C. of quality and make as approved by E ngineer-in-charge |
| 240 | P/FP.V.C. low level flushing cistern with manually controlled device (handle lever) conforming to IS: 7231, with all. |
| 241 | 10 litre capacity -white |
| 242 | P/F P.V.C. waste pipe for sink or wash basin i/c P.V.C. waste fittings complete. |
| 243 | Flexible pipe |
| 244 | 32mm dia. |
| 245 | Providing and fixing grating of approved quality for Nahni trap. |
| 246 | Stainless steel |
| 247 | 100 mm nominal diameter |
| 248 | WATER SUPPLY |
| 249 | Earth work in excavation in foundation trenches ordrainsi/c. dressing of sides and ramming of bottoms lift upto 1.5m including getting out the excavated soil anddisposalof surplusexcavated soil as directed,within a lead of50m in Hard dense Soil |
| 250 | Fillingavailableexcavated earth(excludingrock) intrenches, pinth, sidesoffoundationsetc. in layers not exceeding 20 cm in depth, consolidation each deposited layer by rammingand watering, lead upto 50mand lift upto 1.5m. |
| 251 | Providing and laying cement concrete in foundation. Plinth excluding the cost of centering and shuttering in 1 : 4 : 8 ( 1 cement :4 c/sand : 8 graded stone aggregate. 40mm. nominal size). |
| 252 | Providing and laying in position specified grade of reinforced cement concrete, excluding cost of centering, shuttering finishing and reinforcement All work upto plinth level :1:2:4 ( 1 cement : 2c/sand : 4 graded stone aggregate 20mm. Nominal size). |
| 253 | Reinforcement for RCC work including Straightening, cutting, bending,placing in position and binding all complete. |
| 254 | (a) Thermo-Mechanically treated bars. |
| 255 | Providing form work i/c shuttering and centering so as to give a rough finish, strutting and propping etc. height of propping and centering below supporting floor to ceiling not exceeding 4m. And removal of the same for in-situ reinforced concrete and plain concrete work in |
| 256 | a) foundation footings, bases of columns etc. and mass concrete. |
| 257 | Steel work in built up tubular trusses(round, square or rectangular tubes erc) including cutting, hoisting, fixing in position and applying a coat of approved steel primer red including welding and bolted including special shape washer etc. complete. |
| 258 | Hot finished welded type tubes |
| 259 | Structure Steel work in single sections fixing with or without connecting plate including cutting, hoisting, fixing in position & applying a priming all complete. |
| 260 | Supplying H.D. bolts 150 cm. long with 12 mm dia iron rod for fixing the post plate or wall plate i/c cost of nuts. |
| 261 | Providing and placing on tcrrace (at all floor levels) polyethylene per litre 10.20 water storage tank, IS : 12701 marked, with cover and suitable locking arrangement and making necessary holes for inlet, outlet and overflow pipes but without fittings and tho baso support for tank. |
| 262 | Providing and fixing white vitreous china laboratory sink including making all connections excluding cost of fittings |
| 263 | 450 x 300 x 150 mm |
| 264 | Providing and fixing G.I. pipes complete with G.I. fittings and clamps i/c cutting and making good the walls etc. (Internal work). |
| 265 | 25 mm nominal outer dia Pipes |
| 266 | 20 mm nominal outer dia Pipes |
| 267 | 15 mm nominal outer dia Pipes |
| 268 | Providing and fixing ball valve (brass) of approved quality, High or low pressure, with plastic floats complete |
| 269 | 25 mm nominal bore |
| 270 | Providing and fixing C.P. brass stop cock (concealed) of standard design and of approved make conforming to 1S.8931. |
| 271 | a) 15 mm diameter |
| 272 | Providing and fixing brass bib cock of approved quality |
| 273 | 15 mm nominal bore |
| 274 | SH:- Internal Electrification and Installation |
| 275 | Sub-Head -I (Wiring) |
| 276 | Wiring for light point / fan point/Exhaush Fan point /call bell point with 1.5 sq.mm FR PVC insulated copper conductor single core cable in surface /recessed steel conduit with piano type switch,phemolic laminated sheet suitable size M.S. box and earthing the point with 1.5 sq.mm FR PVC insulated copper conductor single core cable etc as required. |
| 277 | Group A |
| 278 | Wiring for light point /power point plug with 2x4 sq.mm FR PVC insulated copper conductor single core cable in surface /recessed steel conduit alongwith 1 no.4.sq.mm FR PVC insulated copper conductor single core cable for loop earting etc as required. |
| 279 | Wiring for circuit / sub main wiring alongwith earth wire with following size of FR PVC insulated copper conductor, single core cable in surface /recessed steel conduit as required. |
| 280 | (a) 2X1.5.mm² +1x1.5mm² |
| 281 | (b) 2X2.5.mm² +1x2.5mm² |
| 282 | (c) 4X4.mm² +2x4mm² |
| 283 | Sub- Head-II |
| 284 | (Fittings & Accessories) |
| 285 | S/F Vertical down lighters with LED 1x10/13 white powder coated CRCA ring, bright finished reflector i/c connection etc. (ref. 538536 BJDR 110/113 WEB/VI, D type CFL 1x10/13 W). |
| 286 | Supplying, installation testing and commissiong of ceiling fan, capacitor type suitable for low voltage operation including wiring the down rods of standard length (upto 30 cm ) with 1.5 sq.mm FR PVC insulated, copper conductor, single core cable including providing and fixing phenolic laminated sheet cover on the fan box etc. as required. (ISI marked approved) |
| 287 | a) 1200 mm sweep |
| 288 | Supplying, Installation of exhaust fan upto 305 mm sweep in the opening, including marking the holes to suit the size of above fan, making good the damage, connection, testing, commissioning etc. as required. |
| 289 | Sub- Head- II |
| 290 | (DB,s & MCB,s) |
| 291 | S/F 6way, (2+6 way) single door single pole and neutral, prewired, sheet steel MCB distribution board, 240V on surfuce/ recessed complete with loose wire box, terminal blocks, tinned copper bus bar, neutral link, earth bar, din bar, detachable gland plate, interconnection, including powder coat painting, earthing etc as reqd. (but without MCB/RCCB/Isolator). |
| 292 | S/F \"B\" series,SP MCB. Supplying and fixing following 5 amps to 32 amps rating 240 Volts, B series, miniture circuit breaker suitable for lighting and other load of following poles in the existing MCB DB complete with connection, testing and commissioning etc as required. |
| 293 | (a) Single Pole and neutral. |
| 294 | S/FDP MCBisolator: Supplying and fixing following rating, double pole,240 volts, isolator in the existing MCB DB complete with connection, testing and commissioning etc. as required. |
| 295 | (b) 63 amps. |
| 296 | Construction of Toilet Complex |
| 297 | EARTH WORK |
| 298 | 1. Earth work in excavation by mechanical means ( Hydraulic excavation)/ manual means over areas (exceeding 30cm in depth. 1.5 m in width as well as 10 sqm on plan) including getting out and disposal of excavated earth, lead upto 50m and lift upto 1.5 m, as directed by the Engineer-in-charge. |
| 299 | Fillingavailableexcavated earth(excludingrock) intrenches, pinth, sidesoffoundationsetc. in layers not exceeding 20 cm in depth, consolidation each deposited layer by rammingand watering, lead upto 50mand lift upto 1.5m. |
| 300 | Supplying and Fillingin plinth with sandy soil under floors i/c watering, ramming, consolidating and dressing complete. |
| 301 | CONCRETE & RCC WORK |
| 302 | Providing and laying cement concrete in foundation. Plinth excluding the cost of centering and shuttering with 1 : 4 : 8 ( 1 cement :4 c/sand : 8 graded stone aggregate. 40mm. nominal size). |
| 303 | 1 : 1.5 : 3 ( 1 cement : 1.5 c/sand : 3 graded stone aggregate. 40mm. nominal size). |
| 304 | R.C.C. work in beams, suspended floors, roofs having slope upto 15` landing, balconies, shelves, chajjas,lintels, bands, plain window sills, staircases and spiral stair cases above plinth level upto floor five level, excluding the cost of centering, shuttering, finishing and reinforcement with 1:1.5:3 (1cement : 1.5 coarse sand :3 graded stone aggregate 20 mm nominal size). |
| 305 | R.C.C. work in walls (any thickness), including attached pilasters, buttresses, plinth and string courses, fillets, columns, pillars, piers, abutments, posts and struts etc.above plinth level upto floor five level excluding cost of centering, shuttering, finishing and reinforcement 1:1.5:3 (1cement : 1.5 coarse sand :3 graded stone aggregate 20 mm nominal size). |
| 306 | Reinforcement for R.C.C. work i/cstraightening, cutting,bending and placing in position and binding allcomplete upto plinth level. With Thermo-Mechanically treated bars. |
| 307 | FORM WORK |
| 308 | Centering and shuttering including strutting, propping etc. and removal of form for : |
| 309 | Foundations, footings, bases of columns, etc. for mass concrete. |
| 310 | Walls (any thickness) including attached pilasters, buttresses, plinth and string courses etc. |
| 311 | Suspended floors, roof, landings, balconies and access platform. |
| 312 | Lintels, beams, plinth beams, girders, bressumers and cantilevers. |
| 313 | Columns, pillars, Piers, Abutments, Posts and Struts. |
| 314 | Weather shade, chajjas, corbels etc., including edges. |
| 315 | BRICK WORK |
| 316 | Brick work in 1st class common burnt clay F.P.S ( non modular ) bricks in foundation and plinth in : Cement motar 1:4 (1cement:4 coarse sand) |
| 317 | Half brick masonary with 1st class common burnt clay F.P.S ( non modular ) bricks in in superstructure above plinth level and upto floor five level in.cement motar 1:3 (1cement:3 coarse sand) |
| 318 | Honey comb brick work 10/11.4 cm thick with 1st class common burnt clay F.P.S ( non modular ) bricks in superstructure above plinth level and upto floor V level in : Cement motar 1:4 (1cement:4 coarse sand) |
| 319 | WOOD WORK |
| 320 | Providing wood work in frames of doors windows, clerestory windows and other framed and fixed in position with hold fast lugs or with dash fastener of required dia and length ( hold fast lugs or dash fastener shall be paid for separately : Local best quality Tolhao wood. |
| 321 | Providing and fixing panelled or penelled and glazed shutters for doors windows, clerestory windows including ISI marked M.S butt hinges bright finished of required size with necessary screws, excluding panelling which will be paid for separately :all complete as per direction of Engineer-in-charge. Local best quality Tolhao wood. 35 mm thick shutters |
| 322 | Providing and fixing aluminium sliding door bolts ISI marked anodised (anodic coating not less tha gradeAC 10 as per IS: 1868) transparent or dyed to required colour shade with nuts and screws etc complete :250 X 16 mm |
| 323 | Providing and fixing aluminium tower bolts, ISI marked anodised (anodic coating not less tha gradeAC 10 as per IS: 1868) transparent or dyed to required colour or shade with necessary screws etc complete :200 X 10 mm |
| 324 | Providing and fixing aluminium handles, ISI marked anodised (anodic coating not less tha gradeAC 10 as per IS: 1868) transparent or dyed to required colour or shade withnecessaryscrews etc complete :125 mm |
| 325 | FINISHING WORK |
| 326 | 12 mm cement plastern of mix : 1:4 (1 cement: 4 coarse sand) |
| 327 | 20 mm cement plaster 1:4 (1 cement: 4 coarse sand) |
| 328 | 6 mm cement plaster of mix :1:4 (1 cement: 3 fine sand) |
| 329 | Finishing walls with water proofing cement paint of required shade : new work (two or more coats applied @ 3.84 kg/10 sqm) |
| 330 | Painting with oil type wood preservative of approved brand and manufacture :New work (two or more coat) |
| 331 | Varnishing with varnish of approved brand and manufacture : Two or more coats of glue sizing with copal varnish over an under coat of flatting varnish. |
| 332 | Providing and applying two coats of fire retardant paint unthinned on cleaned wood/ ply surface @ 3.5 sqm per litre per coat including preparation of base surface as per recommendations of manufacturer to make the surface fire retardant |
| 333 | Applying one coat of water thinnable cement primer of approved brand and manufacture on wall surface :Water thinnable cement primer |
| 334 | wall painting with plastic emulsion paint of approved brand and manufacture to give an even shade : Two or more coats on new work |
| 335 | Painting top of roofs with bitumen of approved quality at 17kg per 10 sqm impregnated with a coat of coarse sand at 60 cudm per 10 sqm including cleaning the slab surface with brushes and finally with a piece of cloth lightly soaked in kerosene oil complete : |
| 336 | Marble stone flooring with 18 mm thick marble stone (sample of marble shalle be approved by Engineer-in-charge) over 20 mm (average) thick base of cement slurry including rubbing and polishing complete with :Agaria White |
| 337 | Tile work in skirting, risers of steps and dado ( upto 2m height) over 12 mm thick bed of cement mortar 1:3 (1cement:3 c/sand) and jointed with grey cement slurry @ 3.3 kg/sqm including pointing in white cement mixed with pigment of matching shade complete.Marble tiles (polished) Raj Nagar. 8mm thick |
| 338 | WATER SUPPLY & SANITORY INSTALLATION |
| 339 | Providing & fixing water closet squatting pan ( Indian type W.C pan with 100 mm Sand Cast Iron P or S trap, 10 litres white P.V.C flushing cistern, including flush pipe, manually controlled device ( handle lever), including cutting and making good the walls and floors wherever required: White Vitreous china Orissa pattern W.C pan of size 580x440 mm with integral type foot rests |
| 340 | Providing and fixing wash basin with C.I brackets, 15 mm dia CP Brass single hole basin mixer of approvedquality and make, including painting of fittings and brackets, cutting and making good the walls wherever required :- A) White Vitreous China Wash basin size 550x400 mm with a 15 mm CP Brass |
| 341 | Providing flanged joints to double flanged C.I/D.I pipes and Specials, including testing of joints :100 mm diameter pipe |
| 342 | Singlehalf stall urinals with 5 litre P.V.C automatic cistern. |
| 343 | Providing & fixing mirror of superior glass (of approved quality) and of required shape and size with plastic moulded frame of approved make and shape with 6mm thick hard board backing :Rectangular shape 1500x450 mm |
| 344 | Providing and fixing UPVC soil, waste, rain water and vent pipes including all requisite fittings, jointing of pipes & fitting with solvent cement, tenching, refilling & testing of joints complete as per direction of Engineer in charge. |
| 345 | a) 75 mm dia |
| 346 | b) 110 mm dia |
| 347 | Providing and fixing brass bib cock of approved quality |
| 348 | 15 mm nominal bore |
| 349 | Providing and fixing C.P. brass stop cock (concealed) of standard design and of approved make conforming to 1S.8931. |
| 350 | 15 mm nominal bore |
| 351 | Providing and fixing ball valve (brass) of approved quality, High or low pressure, with plastic floats complete |
| 352 | 25 mm nominal bore |
| 353 | Providing and Chlorinated polyvinyl chloride ( CPVC) pipes aving thermal stability for hot and cold watter supply including all CPVC plain and brass treaded fittings, i/c fixing pipe with clamps at 1.00 m spacing. This includesjoining of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good te same including testing of joints compare as per directiopn of engineer in charge. |
| 354 | Concealed work, including cutting chases and making good the walls etc. |
| 355 | 15 mm nominal outer dia pipes |
| 356 | 20 mm nominal outer dia pipes |
| 357 | 25 mm nominal outer dia pipes |
| 358 | Providing and Chlorinated polyvinyl chloride ( CPVC) pipes aving thermal stability for hot and cold watter supply including all CPVC plain and brass treaded fittings. This includesjoining of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good te same including testing of joints compare as per directiopn of engineer in charge. |
| 359 | External works |
| 360 | 25 mm nominal outer dia pipes |
| 361 | Providing and placing on tcrrace (at all floor levels) polyethylene per litre 10.20 water storage tank, IS : 12701 marked, with cover and suitable locking arrangement and making necessary holes for inlet, outlet and overflow pipes but without fittings and tho baso support for tank. |
| 362 | Providing and Fixing PTMT liquid soap container 109mm wide, 125 mm high and 112 mm distance from wall of standard shape with bracket of the same materials with snap fitting of approved quality and colour,weighing not less than 105 gms. |
| 363 | 600 mm long towel rail with total length of 645 mm, width 78 mm and effective height of 88 mm, weighing not less than 60 gms. |
| 364 | SH:- Internal Electrification and Installation |
| 365 | Sub-Head -I (Wiring) |
| 366 | Wiring for light point / fan point/Exhaust Fan point /call bell point with 1.5 sq.mm FR PVC insulated copper conductor single core cable in surface /recessed steel conduit with modular type switch,phemolic laminated sheet suitable size M.S. box and earthing the point with 1.5 sq.mm FR PVC insulated copper conductor single core cable etc as required. |
| 367 | Group C |
| 368 | Wiring for circuit / sub main wiring alongwith earth wire with following size of FR PVC insulated copper conductor, single core cable in surface /recessed steel conduit as required. |
| 369 | a) 2X1.5.mm² +1x1.5mm² earth wire |
| 370 | b) 2X2.5.mm² +1x2.5mm² earth wire |
| 371 | Sub- Head-II |
| 372 | ( Fittings& Accessories) |
| 373 | S/F Recess Mounting LED down Lighter BGSL 0101WH,220223,cast aluminium housing fixed with collimated lens,1x1W white LED mounted on MCPCB ,extruded Al heat sink spring loaded mounting clips, complete with connections etc as reqd. |
| 374 | Supplying, installation testing and commissiong of ceiling fan, capacitor type suitable for low voltage operation including wiring the down rods of standard length (upto 30 cm ) with 1.5 sq.mmFR PVC insulated, copper conductor, single core cable including providing and fixing phenolic laminated sheet cover on the fan box etc. as required. (ISI marked approved) |
| 375 | a) 1200 mm sweep |
| 376 | Supplying, Installation of exhaust fan upto 305 mm sweep in the opening, including marking the holes to suit the size of above fan, making good the damage, connection, testing, commissioning etc. as required. |
| 377 | Supply and fixing of following size of PVC casing and capping along with accessories etc. |
| 378 | (a) 20mm |
| 379 | Sub- Head- III |
| 380 | (DB,s & MCB,s) |
| 381 | Supplying and fixing following way, single pole and neutral ( SPN) , sheet steel, MCB disbutribution board ,240 Volts on surface / recess, neutral bus bar, earth bar, din interconnection,s phosphatized and power paintted including earthing etc. as required.( But without MCB/RCCB/Isolator). |
| 382 | (a) 4 way singleDoor |
| 383 | S/F \"B\" series,SP MCB. Supplying and fixing following 5 amps to 32 amps rating 240 Volts, B series, miniture circuit breaker suitable for lighting and other load of following poles in the existing MCB DB complete with connection, testing and commissioning etc as required. |
| 384 | (a) Single pole and neutral |
| 385 | S/FDP MCBisolator: Supplying and fixing following rating, double pole,240 volts, isolator in the existing MCB DB complete with connection,testing and commissioning etc. as required. |
| 386 | (a) 63 amps. |
Copyright © 2025 · All Rights Reserved. Terms of Usage | Privacy Policy