Bids Are Invited For 80000 , Custom Bid For Services - 32000 , Custom Bid For Services - 17500 , Custom Bid For Services - 12000 , Custom Bid For Services - 30000 , Custom Bid For Services - 35000 , Custom Bid For Services - 20000 , Custom Bid For Services - 24000 , Custom Bid For Services - 40000 H-019 H-187 Plastic Hexagon Shape Dome Bolt Nut Protection Caps Of Crane Deteriorated. Protection Caps To Be Renewed As Per Sample. ( Mat- Polyethylene, Qty- 20 Nos, Mat- Yard Supply ) H-020 Securing Clamp With Wire Locking Pin Arrangement Of Erb Securing Cradle Kink / Diameter Reduced. Securing Clamp With Wire Locking Pin Arrangement To Be Renewed As Per Sample. ( Mat- Ss, Qty- 04 Nos, Mat- Yard Supply ) H-021 Securing Clamp With Wire Locking Pin Arrangement Of Expansion Tank Cover Flap And Excess Grill Of Engine Bay Exhaust Deteriorated. Securing Clamp With Wire Locking Pin Arrangement To Be Renewed As Per Sample. ( Mat- Ss, Qty- 04 Nos, Material- Yard Supply ) H-022 Rubber Beading Of Engine Bay Hatch Perished And Deteriorated. Rubber Beading To Be Renewed As Per Sample. ( Length- 06 Mtrs, Material- Neoprene Rubber, Qty-02, Material- Yard Supply ) H-024 02 In Nos. Nylon Strap For Securing Of Life Rafts Perished And Deteriorated. Securing Strap Be Renewed As Per Sample. ( Length- 1.5 Mtrs Each, Materialnylon, Qty- 02 Nos. ) H-026 Overhead Ceiling Panel In Passenger Cabin Deteriorated And Corroded. Overhead Ceiling Panel To Be Renewed As Per Sample. ( Material- Aluminum, Size Of Panel2.50×0.20 Mtrs, Qty- 05 Nos ) H-017 H-191 Sliding Mechanism Of Chart Table Drawer Fitted In Passenger Cabin Defective And Deteriorated. Sliding Mechanism To Be Renewed As Per Sample. ( Qty- 02 Nos, Mat-Ss, Mat- Yard Supply ) H-018 Rubber Beading Of Emergency Window In Crew Cabin Perished And Deteriorated. Rubber Beading To Be Renewed As Per Sample. ( Length- 1.5 Mtrs Each, Materialneoprene Rubber, Qty- 02 Nos, Mat- Yard Supply ) H-015 H-189 Sliding Mechanism Of Chart Table Drawer Fitted In Passenger Cabin Defective And Deteriorated. Sliding Mechanism To Be Renewed As Perp Sample. ( Qty- 02 Nos, Mat-Ss ) H-016 Nylon Strap Of Aft & Fwd Ballast Tank And Fresh Water Tank Perished And Deteriorated. Nylon Strap With Ratchet Type Lock To Be Renewed As Per Sample. ( Length- 2.5 Mtrs Each, Material- Nylon, Total Qty- 10 Nos, Material- Yard Supply ) H-030 Port And Stbd Gullwing Door Locking Mechanism Not Working. Locking Mechanism To Be Renewed Along With Handles And Proved For Satisfactory Operations. ( Mat- Ss, Qty- 02 Nos, Material- Yard Supply ) H-031 Nylon Strap For Securing Of Life Rafts Perished And Deteriorated. Securing Strap Be Renewed As Per Sample. ( Length- 1.5 Mtrs Each, Material- Nylon, Qty- 02 Nos ) H-032 Securing Clamp With Wire Locking Pin Arrangement Of Expansion Tank Cover Deteriorated. Securing Clamp With Wire Locking Pin Arrangement To Be Renewed As Per Sample. ( Mat- Ss, Qty- 02 Nos, Material- Yard Supply ) H-033 Bracket Clamps Welded On Outer Engine Exhaust Pipe And Wire Securing System Deteriorated And Thinned Down Due To Material Ageing. Securing Bracket And Wire Locking Mechanism To Be Renewed By Welding. ( Size Of Bracket- 04×03 Inch, Thickness- 05Mm, Mat- Aluminum, Qty- 04 Nos, Material- Yard Supply ) H-034 Steering Oil Tank Cover Side Plate Deteriorated And Thinned Down. Plate To Be Renewed As Per Sample. Inway Job Includes Followings:- ( A ) Removal And Fitment Of Steering Oil Tank Cover. ( B ) Fabrication And Fitment Of Plate As Per Sample. ( Size Of Plate- 350×250 Mm, Qty- 01 No. ) H-035 Plastic Hexagon Shape Dome Bolt Nut Protection Caps Of Crane Securing Nuts & Bolt Deteriorated. Protection Caps To Be Renewed As Per Sample. ( Matpolyethylene, Qty- 20 Nos, Material- Yard Supply ) E-034 H-191 Hydraulic Oil Leakage Observed From Steering Cylinder. Suspect Seal Worn Out. Seal Kit To Be Renewed As Per Sample And System To Be Proved For Sat Operation. E-035 Exhaust Leakage Observed From Stbd Main Engine Inner Side Exhaust Manifold. Defect To Be Rectified And Proved For Sat Operation. Inway Job Includes:- ( A ) Removal And Re-Fitment Of Exhaust Manifold. ( B ) Gasket To Be Replaced. ( Spares Cg Supply ) 2. Price Bid Format Is Placed At Annex-B Enclosed. 3. Consignee Details: Headquarters, No. 15 Coast Guard Dist ( North Guj ) Post Box No.16, Port Okha, Dist: Devbhumi Dwarka, Gujarat-361350 4. Technical Details: ( A ) Specifications / Drawings - Na ( B ) Requirement Of Testing / Commissioning / Routines –Yes ( C ) Any Other Details, As Considered Necessary – All The Spares Required For Defect Rectification Will Be Supplied By Firm. No Spares Will Be Provided By Coast Guard And System To Be Proved For Satisfactory Operation. 5. Two Bid System: In Respect Of Two Bid System, Bidders Are Required To Furnish Clause By Clause Compliance Of Specifications Bringing Out Clearly The Deviations From Specifications, If Any. The Bidders Are Advised To Submit The Compliance Statement In The Following Format Along With The Technical Bidser Technical Bid Requirements Yes / No Remarks ( A ) Emd Yes ( B ) Gst Registration Certificate Yes ( C ) Pan Certificate Yes ( D ) Repair / Renewal / Routines On Similar Jobs ( Work Done To Be Enclosed ) Yes ( E ) Firm Registered In Coast Guard / Indian Navy / Central Govt Organization Yes Part Iii – Standard Conditions Of Rfp ( You Are Required To Give Confirmation Of Your Acceptance Of The Standard Conditions Of The Rfp Mentioned Below Which Will Automatically Be Considered As Part Of The Contract ( Wherever Applicable ) Concluded Between The Buyer And Seller. Failure To Do So May Result In Rejection Of The Bid Submitted By The Bidder. Only The Relevant Portions Of The Standard Conditions Have Been Reproduced Below. For The Complete Conditions You May Log On To Ministry Of Defence Website. ) 1. Law: The Contract Shall Be Considered And Made In Accordance With The Laws Of The Republic Of India. The Contract Shall Be Governed By And Interpreted In Accordance With The Laws Of The Republic Of India. E-026 H-187 & H-189 Main Engines Air Filter Securing Clamp Worn Out. Same To Be Fabricated And Fitted As Per Sample ( Mat: Ss, Dia- 300 Mm, Qty- 08, Locking Clamp Type ) E-027 H-187 & H-189 Ac Compressor Safety Guard To Be Fabricated As Per Sample ( Mat- Ss, Length450mm, Width- 300 Mm, Qty-02 ) E-028 H-189 & H-191 Canvas Cover Worn Out ( Mat- Canvas, Qty-03 ) And Securing Plate Deteriorated From Base Of Cpp Tank System. ( Mat- Aluminum, Qty-02 ) . Same To Be Fabricated As Per Sample. E-029 H-187 Bme Exhaust Manifold And Turbocharger Lagging Perished And Deteriorated. Lagging To Be Renewed And Secured With Heat Resistance Stainless Steel Wire Mesh As Per Sample. ( Dia- 150 Mm, Length-18 Mtrs Mat- Glass Wool ) E-037 Air Leakage Observed At Multiple Locations From Bme Intercoolers Copper Tubes. Copper Tubes To Be Repaired And Pressure Tested Upto 02 Bar. Defect To Be Rectified And Proved For Satisfactory Operations. Inway Job Includes:- ( A ) Removal And Refittment Of Intercoolers. ( B ) Removal Of Rubber Joints And Refittment. ( All Spares / Material Firm Supply ) . Total Quantity :