| 1 | Aerial Bunched Cable LT 3x70 + 1x16 + 1x50 sq.mm (Insulated Messenger) |
| 2 | Anchor / Dead End Clamp for AB Cables 70 sq.mm |
| 3 | Suspension Clamp for AB Cables 70 sq.mm |
| 4 | Cable Tie UV Plast Heavy Duty 300 mm |
| 5 | End Cap for LT ABC 70 Sq mm |
| 6 | End Cap for LT ABC 50 Sq mm |
| 7 | End Cap for LT ABC 16 Sq mm |
| 8 | Insulation Piercing Connector - Main: 16 sq mm to 95 sq mm; Tap : 1.5 sq mm to 16 sq mm |
| 9 | Insulation Piercing Connector - Main: 16 sq mm to 95 sq mm; Tap : 16 sq mm to 95 sq mm |
| 10 | PIERCING CONNECTOR for ABC TO ABC (TEE CONNECTION) |
| 11 | Post mounting Distribution box for effecting LT service connection |
| 12 | Stainless Steel Strap [20 mm x 0.7 mm] |
| 13 | Stainless Steel Buckle Slot width 20.5 mm x 1.5 mm,Thickness 1.2 mm. |
| 14 | Earth Connector 95 Sqmm |
| 15 | Pre-Insulated Midspan Joints and Terminal Lugs 70 Sq.mm |
| 16 | Pre-Insulated Midspan Joints and Terminal Lugs 50 Sq.mm |
| 17 | Pre-Insulated Midspan Joints and Terminal Lugs 16 Sq.mm |
| 18 | Satellite connector – Main : 16 sq mm to 95 sq mm; Tap : 1.5 sq mm to 35 sq mm (4 way) |
| 19 | Cable 1.1 kV PVC AL 4c x25 sq mm (Un Armoured) |
| 20 | INSULATION TAPE for ABC |
| 21 | Insulation Piercing Satellite connector – Main : 16 sq mm to 95 sq mm; Tap : 4 sq mm to 50 sq mm (4 way) |
| 22 | Cable Tie UV Plastic Heavy Duty 500 mm Length |
| 23 | Insulation Piercing Connector Main 16 sq mm to 95 sq mm; Tap 4 sq.mm to 35 sq.mm |
| 24 | Insulation Piercing Connector - Main: 16 sq mm to 95 sq mm; Tap : 16 sq mm to 95 sq mm |
| 25 | IPC FOR ABC 3X95+1X70+1X16 Tap 1.5-10 sqmm |
| 26 | Stainless Steel Buckle Slot width 10.5 mm x 1.5 mm,Thickness 1.2 mm. |
| 27 | Stainless Steel Strap 10 mm x 0.7 mm-For clamping earth wire |
| 28 | Insulation Piercing Connector Main 16 sq mm to 95 sq mm; Tap 4 sq.mm to 50 sq.mm |
| 29 | Pipe GI 40 mm dia -2.5 m Length( Earth Pipe) |
| 30 | Ferrules 5 Sq.mm(GI) |
| 31 | Earthing Coil GI 115 Turns 50 mm internal Dia dia |
| 32 | G.I.WIRE. 4MM (8 SWG) |
| 33 | Stringing of 1.1 kV Aerial bunched cable of size 3 x 70 + 1 x 16+1x 50 sqmm with bare/insulated Messenger through existing poles |
| 34 | Erection of Anchor clamp / dead end clamp for LT ABC of any size |
| 35 | Erection of suspension clamp for LT ABC of any size |
| 36 | Installing One No. Insulation piercing connector of size Main :16 to 95 ,Tap:1.5 to 16 Sq.mm |
| 37 | Installation of Insulation piercing connector for main to service line main :16-95 sqmm, Tap 16-95 sqmm |
| 38 | Installation of Insulation piercing connector for main to service line main :16-95 sqmm, Tap : 4-35 sqmm |
| 39 | Fitting of one No. pole top service connection box of standard size (up to 4 way) using ss strap/B&N of suitable size in to the PSC/A poles at the standard height excluding giving connections |
| 40 | Providing one Earth using earth pipe incl. digging separate pit at standard distance away from the pole/structure & backfilling. |
| 41 | Installation of Pre-insulated straight through joints for 70sqmm cable |
| 42 | Installation of Pre-insulated straight through joints for 50sqmm cable |
| 43 | Installation of Pre-insulated straight through joints for 16sqmm cable |
| 44 | Installing One No. 4 way Satellite Connector of size Main :16 to 95, Tap:4 to 35 Sq.mm to the LT AB cable of Standard size |
| 45 | Providing End Caps |
| 46 | Providing Cable Tie |
| 47 | Providing one Coil Earth using GI earth wire, digging separate pit at standard distance away from the pole/structure & backfilling. |