Housing Urban and Rular Development Government Departments Closing in 0 days TDR #38858780

Tender For Modernization Of Visitor Room (Mulakaat Kaksh) At Central Jail Ajmer Sr.11

Issued by Government Departments · ajmer, Rajasthan
Tender Value
16 Lakhs
Estimated cost
Bid Submission
12 Aug 2023
0 days left
EMD
32000
Bank guarantee accepted
Document Fee
1180
Non-refundable
Tender Type
Online

Tender Overview

Competition Type
NCB
Bidding Type
Tender
Location / State
ajmer → Rajasthan
EMD Exemption
Not Available
Quantity
Not Available

Project Description

Modernization Of Visitor Room ( Mulakaat Kaksh ) At Central Jail Ajmer Sr.11

BOQ

Name of Work : Modernization of Visitor Room (Mulakaat Kaksh) at Central Jail Ajmer)
Sl. No. Item Description
1Demolishing cement concrete manually/ by mechanical means including disposal of material within 50 metres lead as per direction of Engineer-in-charge.1: 3: 6 or richer mix.
2Dismantling old plaster or skirting, raking out joints and cleaning the surface for plaster including disposal of rubbish to the dumping ground within 50 meter lead.
3Dismantling doors, windows and clearstory windows steel or wood shutter including chowkhats and holdfasts etc. complete and stacking within 50 meters lead:Of area 3 square meter and below.
4Taking out doors, windows and clearstory windows shutters (steel or wood) including stacking within 50 meters lead:
5Of area 3 square meter and below.
6Dismantling CC jali including cost of making grooves in plaster and making good and including disposal of unserviceable surplus material and stacking of serviceable material with in 50 meters lead as directed by Engineer-in-charge..
7Brick work with F.P.S. bricks of class designation 75 in superstructure above plinth level upto floor V level in all shapes and sizes in :Cement mortar 1 : 6 (1 cement : 6 coarse sand)
8Providing and laying in position cement concrete including curing, compaction etc. complete in specified grade excluding the cost of centering and shuttering - All work up to plinth level. M10 grade Nominal Mix 1: 3: 6 (1 cement : 3 coarse sand : 6 graded stoneaggregate 20mm nominal size).
9Grading roof water proofing treatment with : Cement concrete 1:2:4 (1-Cement:2-coarse sand:4-graded stone aggregate 20mm nominal size)
10Kota stone slab flooring 25 mm thick over 20 mm (average) thickbase laid over and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and polishing completewith base of cement mortar 1 : 4 (1 cement : 4 coarse sand)For area of each slab from 901 to 2000 Sq.Cm :
11Kota stone slabs 25 mm thick in risers of steps, skirting, dado and pillars laid on 12 mm (average) thick cement mortar 1:3 (1 cement 3 coarse sand) and jointed with grey cement slurry mixed with pigment to match the shade of the slabs, including rubbing and polishing complete
12Providing and fixing steel gate, grating , and grills made of angles, tees, square bars, flats,or black pipe with holdfast and fittings complete as per design and drawing including cutting welding and fabrication with priming coat of red oxide
13Providing and fixing T-iron frames for doors, windows and ventilators of mild steel Tee-sections, joints mitred and welded with 15x3 mm lugs 10cm long embedded in cement concrete blocks 15x10x10 cm of 1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size) or with wooden plugs and screws or rawl plugs and screws or with fixing clips or with bolts and nuts as require including fixing of necessary butt hinges and screws and applying a priming coat of approved steel primer.
14Providing&fixingprecastcementconcretecoping1:2:4mix50mmthickcompleteas per specification :
15Half brick masonry in Superstructure , above plinth level upto floor Vlevelusing bricks of designation 75
16Cement mortar 1 : 4 (1 cement : 4 coarse sand)
17Add extra providingand placing in position 2 Nos. ,6mm Ø M.S. barat every thirdcourse of half brick masonry .
18Repairs to plaster of thickness 12mm to 20mm in patches of area 2.5 sq. metres and under including cutting the patch in proper shape, raking out joints and preparing and plastering the surface of the walls complete including disposal of rubbish to the dumping ground within 50 m lead With cement mortar 1 :4 ( 1 cement : 4 coarse sand)
19Repair to stone masonary in cement sand mortar 1:6 with old and new stone.
20Plaster on new surface on walls in cement sand mortar 1:4 including rackingofjointsetc. complete fine finish :25 mm thick.
216 mm thick cement plaster to ceiling of mix1:3 (1cement : 3-fine sand)
22Plaster on new surface on walls in cement sand mortar 1:6 including racking of joint etc. complete fine finish : 20mm thick.
23Providing and applying white cement based puttyover plastered surface to prepare the surface even and smooth complete :- New Plastered Surface (three or more coats)
24Distempering with oil bound washable distemper of approved brand and manufacture to give an even shade including all scaffolding:Newwork(twoormorecoats)overandincludingscrappingandprimingcoatwithcement primer.
25Painting exterior surface ofWallwith 100% acrylic exterior paint of approved brand and manufacture to give an even shade with two or more coats including prepartion of base with sand papering, primer, putty,etc complete in all respect including scaffolding and safety provision Old Work
26Painting with synthetic enamel paint of approved brand and manufacture togive an even shade :
27Providing and fixing Granite stone slab mirror polished and machine edge cut in walls, pillars, steps, Shelves, Sills Counters, Floors etc. laid on 12mm (Av.) thick base of cement mortar 1:3 (1 cement : 3 coarse sand) jointing with white cement mortar 1:2 (1white cement : 2 marble dust) with pigment to match the shade of the marble slab including grinding, rubbing and polishing complete.South Zed Black Above 3601 Cm2 Slabs
28Providing & fixing factorymade 100% Solid WPC (Wood Polymer Composite) Door Frame 90mm x 45 mm ( Moulded ) Single Rebated,, made from Wood Polymer Composite (Single Extruded Process) material comparising of virign PVC polymer of K Value 58-60 ( Suspemsion Grade), Calcium Corbonate and Natural Fibers ( Wood Powder/ Rice Husk/ Wheat Husk) and Nor toxic additives fabricated with meter Joints after applying PVC solvent Cement & screwed with full body treaded star headed srews having minimum frame density of 780 kg/ cbm & manufactured by an ISO 9001 - 2015 Certified Company, having good screw holding capacity ( Screw Withrawal strength of 2200 N ( Face) & 1100 N ( Edge), Minimum Compissive Stength of 58 N/mm2, Moduus of elasticity 900N/mm2 and resistance to spread of flame of class A category with property of being termite / borer proof , water / Moisture Proof & Fire retardant & Fixed in postion with SS Dash Fasterns / Hold Fast of reuired dia and lenght, all as per specifications drawings as directed by the Engineer-In-Charge. Material test certificate and authentication should be compulsory provided by the manufacturing company ( Hold Fast or Dash Fastners shall be paid seperately)
29Anodised aluminum (anodised transparent 81 dyed to required shade according to IS : 1868. (Minimum anodic coating of grade AC 15, Anodizing to be got done from approved Anodizer) Anodised aluminum (anodised transparent 81 dyed to required shade according to IS : 1868. (Minimum anodic coating of grade AC 15, Anodizing to be got done from approved Anodizer)
30Powder coating aluminum( minimum thickness of powder coating 50 micron)
31Providing and fixing wood panelling or panelling and glazing in panelled or panelled and glazed shutters for doors, windows and clerestory windows (Area of opening for panel inserts excluding portion inside grooves or rebates to be measured). Panelling for panelled and glazed shutter 25 mm to 40 mm thick
3210 mm thick glass
33Extra for providing toughened glass panes instead of ordinary float glass panes in doors, windows and clerestory window shutters. (Area of opening for glass panes excluding portion inside rebate shall be measured).
34Providing and fixing external grade board solid core single leaf flush door shutters ISI 2202-67 marked using Phenol formal dehyderesinin glue both sides with approved steel fittings complete as per annexure \"A\":Commercial Veneer both side 35 mm thick .
35Extra for providing external lipping with 2ndclass teak wood battens 6 mm minimum depth on all edges of shutters (over all area of door shutter to be measured) Over item no. 8.13.
36Providing & laying broken glazed titles on roof ( broken glazed tilesnot less than 9 Kg/Sqm) on top of hot bitumen @ 1.7 Kg/Sqm. (1.40 Kg ofVG-40 (30/40 )grade and 0.30 Kg/Sqm. OfVG-10 (80/100) grade) and joints filled with cement mortar 1 :2 (1 cement:2 marble dust mixed with water proofing compund all complete as per direction of Engineer-in-charge.
37Providing gola 75x75 mm in cement concrete 1:2:4 (1 cement : 2coarse sand : 4 stone aggregate 10mm and down gauge) includingfinishing with cement mortar 1:3 (1 cement : 3 fine sand) as per standard design :
38Making khurras 450 x 450mm with average minimum thickness 50mmcement concrete 1 : 2:4 over P.V.C. Sheet 1 Mtr. x 1 Mtr. x 40micron finished with 12mm cement plaster 1 : 3 and onecoat of neat cement, rounding edges and making and finishing the out let complete.
39Providing and laying APP (Atactic Polypropylene Polymer) modified prefabricated five layer 3mm thick water proofing membrane, black finished reinforced with non-woven polyester mattconsisting of a coat of bitumen primer for bitumen membran @ 0.40 Itr/sq.mt. by the same membrane manufacture of density at 25°C, 0.87-0.89 kg/ltr and viscosity 70-160 cps. Over the primer coat the layer of membrane shall be laid using Butane Torch and sealing all joints etc., and preparing the surface complete. The vital physical and chemical parameters of the membrane shall be as under Joint strength in longitudinal and transverse direction at 23°C as 650/450N/5cm. Tear strength in longitudinal and transverse direction as 300/250N. Softening point of membrane not less than 150°C. Cold flexibility shall be upto -2°C when tested in accordance with ASTM, D-5147. The laying of membrane shall be got done through the authorized applicator of the manufacturer of membrane.3 mm thick
40Wiring of light point/ fan point/ exhaust fan point/ call bell point with1.5 sq. mm nominal size FR PVC insulated unsheathed flexible copperconductor 1.1 kV grade and 1.5 sq. mm nominal size FR PVC insulatedunsheathed flexible copper earth conductor 1.1 kV grade (IS:694) inrecessed ISI marked MMS ( IS:9537 P - III ) virgin material PVC conduit &it\"s ISI marked (IS:3419-1988) accessories, round tiles, 1.2 mm thick HotDipped Galvanized Modular Box with earth terminal, 10A Modularswitch,Modular face plate with grid plate, 3 pin ceiling rose / Holder /3way connector, screws, making connections, testing etc. as required.For specification of copper Conductor, Phenolic Laminated sheet\"s &Electrical/ Wiring accessories refer Chapter E - 04, E - 05 & E - 07 Foradditional technical parameters of product / work refer Annexure \"A\"attached with this BSR
41Short point (up to 3 mtr.)
42Medium point (up to 6 mtr.)
43Long point (up to 10 mtr.)
44Description Wiring of 3/5 pin 6 amp. Light plug point with 1.5 sq. mm nominal sizeFR PVC insulated unsheathed flexible copper conductor 1.1 kV grade and 1.5 sq. mm nominal size FR PVC insulated unsheathed flexible copper earth conductor 1.1 kV grade(IS:694) in recessed ISI marked MMS ( IS:9537 P - III ) PVC conduit & it\"s ISI marked (IS:3419- 1988)accessories, Hot Dipped Galvanized Modular box of 1.2 mm thick with earth terminal, 10 A modular switch, 3/5 pin 6 A modular socket, Modular face plate with grid plate, screws, making connections, testing etc. as required. For specification of copper Conductor, Phenolic Laminated sheet\"s & Electrical/ Wiring accessories refer Chapter E - 04, E- 05 & E - 07 For additional technical parameters of product / work refer Annexure \"A\" attached with this BSR
45On board
46Medium point (up to 6 mtr.)
47Long point (up to 10 mtr..)
48Supplying and fixing of power plug point with Modular accessories as perPWD specification for electrical Works, on hot dipped galvanized modularbox of 1.2 mm thick with earthing terminal/connector on surface or inrecessed with suitable size of modular face place with grid plate and coverplate including cost of ISI marked modular 16 amp. Switch (IS :3854) and6/16 amp. socket outlet (IS:1293) making connection , testing , etc. asrequired. For specification of Wiring accessories refer Chapter E - 07related item & For additional technical parameters of product / work referAnnexure \"A\" attached with this BSR
49Providing & Fixing of BEE Star rated copper wounded double ball bearing capacitor start, aluminium body & Metallic blade ceiling fan Conforming to all the performance requirements laid down in IS 374:2019 including all amendments, as applicable ; & Carry BIS licensing (i.e. ISI marking) with down rod up to 80 cm with secondary support safety cable ( steel rope) , cotter pin with 3 x 1.5 sq.mm pvc insulated flexible copper conductor making connection testing etc. as required. All as per pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annexure \"A\" attached with this BSR.
501200 mm Sweep BEE 3 Star rated (service value >=5.0 to< 5.5
51Providing & Fixing of IS 11037:1984 marked non modular socket size flush type 180 watt rotary minimum 5 step fan regulator with CM/L no. printed and made out from industrial grade Polycarbonate or fire resistant ABS material including making connection testing etc. as required.All as per pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annexure \"A\" attached with this BSR .
52Providing & Fixing of IP20 SMD Mid Power LED batten type integrated light fixture made from Powder coated Extruded aluminium housing with in built driver , System lumen efficacy = 110 lm/Watt output, internal surge protection of 2.5 KV with Short & Open circuit protection ,THD < 10% , P. F.=0.95, CRI >80 , life time of minimum 50000 Burning Hours with , 70% of intial Lumen maintaned till life ends , CCT 3000°K / 4000°K / 5700°K /6000°K/6500°K (As per ANSI Bin) , Maximum power consumption should not more than the specified rating and Fixture shall be of BIS standard and trade mark certificate ( T.C.). Manufactures Word Mark/ Name Engraved/ Embossing/ Screen printing on housing. OEM must have its own in house NABL lab setup for all testing facilities for LED fixtures. (LM79 & LM80) certificate/ Report from OEMshall besubmitted. All asper pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annexure \"A\" attached with this BSR .
531170mm(+/-10%) LED batten with min. lumen output 2200 lm
54Providing & Fixing of Recessed/surface mounting heavy duty horizontal type Double Door ( Metal / Glazed )Distribution board with Metal end box made out from Galvanized steel / CRCA sheetnot less then 1.2 mm thick conforming to IS-8623-1 & 3 / IEC61439- 1 & 3, powder painted complete with reversible door (fordouble door DB only )100 amp. insulated copper bus bar/shortinglink , copper neutral link, copper earth link , color codedinterconnecting wire set of suitable rating and dinbar,maskingsheet, making internal DB terminations with copper lugs, Ferrules,detachable gland plate, including making connections, testing etc.as required. OEM shall have submit NABL / CPRI / ERDA accrediatedlab type test reports & All as per pre approved by Engineer incharge. For additional technical parameters of product / work referAnnexure \"A\" attached with this BSR
558 Way (8+2)
56Providing & Fixing of 240/415 V AC MCB with positive isolation of 10 kA breaking capacity (B/ C/D tripping characteristic as per type ofload and site requirement) 4 KV impulse withstand voltage, ISImarked IS 8828(1996) / conforming to IEC 60898-1 2002, IEC 60947-2, low watt losses, trip free mechanisum , energy limiting of class 3 as per IEC, minimum phase termination capacity of 35sq.mm. ,conductor line load reversibility , IP 20 contact protection and fittedin existing distribution board/sheets, minimum electrical operation20,000 upto 20 A rating and 10,000 upto 63 A, 5000 for 80 A &above rating including making connections, testing etc. as required.OEM shall have submit NABL / CPRI / ERDA accrediated lab typetest reports & All as per pre approved by Engineer in charge. Foradditional technical parameters of product / work refer Annexure\"A\" attached with this BSR
57Double pole MCB(With B/C curve tripping Characteristics)
586 A to 32 A rating
59Single pole MCB (With B/C curve tripping Characteristics)
606 A to 32 A rating
61Supplying and drawing FR PVC insulated & unsheathed flexible copperconductor as per PWD specification for electrical Works with ISImarked (IS:694) and as per IS 8130 : 2013 of 1.1 kV grade . Wire shouldbe made from 99.90 % purity copper, class 5 stranding in acc. toIS:8130/IEC 60228 for lower watt loss , oxygen free for less chances of oxidization, insulation PVC type A/C/D , flame retardant as per IS 10810-53, better amperage rating as per IS:3961 part 5, in existing surface or recessed PVC/ MS conduit/casing capping makingconnections with Copper Lugs of suitable size, Ferrules,testing etc. asrequired. OEM Must have its own in house NABL lab setup for alltesting facilities for wires. For additional technical parameters ofproduct / work refer Annexure \"A\" attached with this BSR
622 x 4.0 sq. mm. + 1 x 2.5 sq. mm.
632 x 2.5 sq. mm. + 1x1.5sqmm
64S&F following sizes (dia.) of ISI marked virgin material MMS ( IS:9537 P -III ) PVC conduit along with ISI marked (IS:3419-1988) accessories asrequired in recess including cutting the wall, covering conduit andmaking good the same as required. For additional technical parametersof product / work refer Annexure \"A\" attached with this BSR
6525 mm
66Providing & Fixing of energy efficient /energy saving IP 20 LED direct retrofit Bulb inexisting holder or fixture as required with system lumen efficacy =100 lm/Watt output ,pf0.95 , CRI >70, minimum life time of minimum 25000 Burning Hours with , 70% of intialLumen maintaned till life ends , CCT 3000°K / 4000°K / 5700°K /6000°K/6500°K (As perANSI Bin) , maximum power consumption should not more than the specified rating andFixture shall be of BIS standard and trade mark certificate ( T.C.). Manufactures WordMark/ Name Engraved/ Embossing/ Screen printing on housing. OEM must have its own inhouse NABL lab setup for all testing facilities for LED fixtures. (LM79/LM80) certificate /Report from OEM shall be submitted. All as per pre approved by engineer in charge . foradditional technical parameters of product/ work, refer Annexure \"A\" attacheded with this BSR
679 Watt
68Providing & Fixing of of Double ball bearing, copper wounded capacitorstart single phase metallic blade fresh air fan, in existing openingincluding cost of hardware , flexible 3 core copper conductor ,makingconnections, testing etc. as required. All as per pre approved by Engineerin charge. For additional technical parameters of products/ work , referAnnexure \"A\" attached with this BSR
69300 mm sweep
70S&F following sizes of ISI marked ( IS:14927 P - II ) virgin material UPVCtrunking along with accessories like coupler, inner, outer, elbow,square box, tee, end cap etc. on surface with screws, expansionfasteners as required. For additional technical parameters of product /work refer Annexure \"A\" attached with this BSR
7150 mm x 50 mm
72Supply, Drawing and Testing of 4 pair, 23 AWG Solid Bare Copper wire insulated with PVC,UTP (Unshielded Twisted Pair), Category 6, Class E, 100 Ohm Impedance, Indoor Cable asper latest ammendments of ANSI/TIA/EIA-568 , The copper conductors should bebalancedtwisted in pairs, seperated by a cross-member fluted pair divider & protected by PVCJacket. Certified performance in a 4-connector configuration upto 100 Mtrs channelrequirements & transmission frequencies up to 250 Mhz. in existing MS/PVCConduits/casing capping including making connections to Information outlets and PatchPanels with jack & ferruling at both ends for identification with necessary tools forpunching, stripping, crimping and testing etc as required complete in all respect. All as perpre approved by Engineer in charge. For additional technical parameters of products/ work, refer Annexure \"A\" attached with this BSR .
73Supply , Installation and Testing of 4 pair, 100 Ohm impedance, Cat 6/6A /Class E/Ea patchcords should be constructed of minimum 23/24 AWG, stranded bare Copper cable withFRPVC/LSZH Jacket, with an enhanced performance by factory moulded RJ45 connectorswith strain relief boots as per ANSI/TIA/EIA 568-C.2 suitable for Cat 6/6A applicationcomplying to latest ammendments Category 6/6A Standards, According. to TIA568C.2,ISO/IEC 11801, EN 50173, IEC 60603-7-51, EN 60603-7, IEEE 802.3an minimum requirementfor 1G BASE-T to 10G BASE-T performance. Patch cords shall be straight thru cablecompatible with both T568-A and T568-B wiring schemes, should support IEEE 802.3af /IEEE 802.3at for POE applications, Minimum 750 to 1000 mating cycles in plug contacts forlong durability, Should support Ethernet 10GBASE-T, 1.2 Gb/s ATM, Token ring 4/16, Digitalvideo and broadband/baseband analog video, Voice over internet protocal (VOIP).All as perpre approved by Engineer in charge. For additional technical parameters of products/ work, refer Annexure \"A\" attached with this BSR .
74Cat 6, U/UTP (Unscreened/Un-sheilded Twisted Pair) Patch Cord
751 Mtr

AI Tender Summary

OUR REF NO 38858780
AUTHORITY Government Departments
TENDER VALUE 16 Lakhs
LAST DATE 12-08-2023
Authority
Authority Name Rajasthan Police Housing & Construction Corporation Limited
Work Description Modernization Of Visitor Room ( Mulakaat Kaksh ) At Central Jail Ajmer Sr.11
Basic Detail
Tender No NIT No. 16 of2023-24MD, RPIDCL, Jaipur
Bidding Type Tender
Location
City ajmer
State Rajasthan
Key Dates
Publish Date 27 Jul 2023
Submission Date 12 Aug 2023
Open Date 14 Aug 2023
Finance
Tender Value 16 Lakhs
Tender Fee 1180
EMD 32000
Exemption Not Available
Document List
c2564ee8-8751-47ed-b1b6-96b8008afc92.html
BOQ_629483.xls
Front_Page_.pdf
Listofapprovedmake.pdf
SpecialCondition.pdf
Tendernotice_1.pdf
Tendernotice_2.pdf
Tendernotice_3.pdf
Tendernotice_4.pdf
Tendernotice_5.pdf
Tendernotice_6.pdf

Unlock Full AI Tender Summary

Get instant access to the complete AI-generated analysis — scope, eligibility, timeline & more.

Instant Access Secure Free
Your details are secure and used only for document delivery.

Tender Timeline

Jul 27, 2023
11:30 IST

Tender Published

Tender notice published.

Completed
Aug 12, 2023
17:00 IST

Bid Submission Deadline

Online submission via eProcurement portal.

Completed
Aug 14, 2023

Bid Opening Date

Technical bids will be opened and evaluated.

Completed

Tender Documents

Download All (ZIP) ↓
html

c2564ee8-8751-47ed-b1b6-96b8008afc92.html

xls

BOQ_629483.xls

pdf

Front_Page_.pdf

pdf

Listofapprovedmake.pdf

pdf

SpecialCondition.pdf

pdf

Tendernotice_1.pdf

pdf

Tendernotice_2.pdf

pdf

Tendernotice_3.pdf

pdf

Tendernotice_4.pdf

pdf

Tendernotice_5.pdf

pdf

Tendernotice_6.pdf

Disclaimer

We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender

TenderDetail