| Sr No | Corrigendum Date | Corrigendum | Type | New Submission Date |
|---|---|---|---|---|
| 1 | 16-08-2023 | Bid Auto Extn Corrigendum | Bid Auto Extn Corrigendum | 23-08-2023 |
| Sl. No. | Item Description |
| 1 | AMC for, servicing, maintanence, repairing completeforPackage type Air conditioning plant of capacity 8.75 TR condensing unit, Model :- DSA1052R1, Make Blue star and kept it in 100% serviceable condition at all times with temperature/ humidity control (temperature24 degree + 2 degre with RH 55% + 5%) inEquiptment room atAF station Kanheri hill at Technical Area.The following scope of work including the above work. (No. of plant=3 Nos, 2 Nos running one standby) (i)Testing, Checking, serviceing the indoor and out door units, Fresh air duct and return air ducts, all the filter, dumper, grill, electric control panel, Intelligent Microprocessor controller complete. (ii) Three Nos AC plants to be made serviceable condition, Two number will running at at time and one number standalternativelythrough auto control switch. (iii)Checking and serviceablity ofall controlling equiptment, Push button , ON -OFF switch , Selector switch on PLC Panels for various mode of operation.. (iv)Checking all the connection of cables end termination for any damge or Loose connection .(v) Checking of compressor, condensing coil, Solenoid valves , auto control switch, Automation system. (vi)Checkingthe pressure of Condensing gas and if required charging the gas.(vii)Checking of allinsulating material and repair/replace.(viii)CheckingFresh air /Return duct,dumper,Grill, repair/maintanence/Replace if needed.(ix) Chekinginstallation of equiptmentand repair if found unserviceable.Note:-(a)Spares for repair including Gas will be measured and paid seperatly in respectively items.(b)Serviceing to be done every month, if additional vist required the same will be born by contractor in his own cost. |
| 2 | Supply and fixing PCB circuit for intelligent cooling ambient sensor suitable for 8.75 TR AC plant.Make Blue star. |
| 3 | Supply and fixing DLT sensor suitable for 8.75 TR AC plant. Make Blue star. |
| 4 | Supply and fixing HP/LP sensor suitable for 8.75 TR AC plant. Make Blue star. |
| 5 | Supply and fixing thermostate suitable for 8.75 TR AC plant Make Blue star. |
| 6 | Supply and fixing blade for condenser blower motor suitable for 8.75TR AC plant.Make Blue star. |
| 7 | Supply and fixing Filter suitable for 8.75 TR AC plant.Make Blue star |
| 8 | Supply and fixing expansion valve for 8.75 TR AC plant.Make Blue star |
| 9 | Taking down and dismantling outdoor fan motor of 8.75 TR AC plant and material and labour for rewinding with supper enamelled copper winding wire as per existing pattern including replacement ofgun metal bushes, shaft, clamps includingtesting and commissioning complete all as specified and directed by Engr-in-charge. |
| 10 | Supply and fixing outdoor (condensor) fan motor of existing capacity and size for 8.75 TR AC plant.Make Blue star |
| 11 | S&F in replacement insulation (closed cell elastomeric insulation in tubing) over copper tubing (suction or discharge) wherever required using approved material & size and thickness of insulation as per manufacturers recommendation for 8.75 TR AC plant.Make Blue star complete all as specified and directed. |
| 12 | Dismantling/taking out defective compressor unit and supply and fixing re-appropriated company sealed compressor scroll type of 4.38TR (suitable for 8.75 TR capacity AC plant) obtained from the factory outlet / authorised dealer under their replacement scheme complete including connecting fitting and fixtures making brazing work and leak test and recharging refrigerant including solering of copper pipes, replacement of foundation rubber bushes, nuts, bolts etc complete all as specified and directed by Engr-in-charge.Note :- This item shall not include cost of gas and gas charging which shall be measured and paid forseparately under respective items . |
| 13 | AMC for ,servicing ,maintanence,repairing completefor Package type Air conditioning plant of capacity 5.5 TR condensing unit ,Model :-DPA661R1 ,Make Blue starand kept it in 100% serviceable condition at all times with temperature/ humidity control (temperature24 degree +/- 2 degre with RH 55% +/- 5%) inEquiptment roomatAF station Thane Site \"P\" .The following scope of work including the above work. (No of units-2 nos, 1 nos running one stand (i)Testing,Checking ,servicing the indoor and out door units,Fresh air duct and return air ducts, all the filter, dumper, grill, electric control panel, Intelligent Microprocessor controller complete.(ii)Checking and serviceable all controlling equiptment, Push button , ON -OFF switch , Selector switch on PLC Panels for various mode of operation.. (iii)checking all the connection of cables end termination for any damge or Loose connection . (iv) Checking of compressour ,condensing coil, Solenoid valves ,auto control switch, Automation system.(v) Checkingthe pressure of Condensing gas and if required charging the gas.(vi) Checking of allinsulating material and repair/replace .(vii) ChekcingFresh air /Return duct,dumper,Grill, repair/maintanence/Replace if needed.(viii) Chekinginstallation of equiptmentand repair if found unserviceable. Note: (a)Spares for repair including Gas will be measured and paid seperatly in respectively items.(b)Serviceing to be done every month, if additional vist required the same will be born by contractor in his own cost. |
| 14 | Supply and fixing in replacement ofPCB circit for intelligent cooling ambient sensor suitable for 5.5 AC plant all as specified and directed by Engineer-in-Charge.Make Blue star. |
| 15 | Supply and fixing in replacement of thermostate suitable for 5.5 AC plant all as specified and directed by Engineer-in-Charge.Make Blue star. |
| 16 | Supply and fixing in replacement of Propeller type PVC blade for condenser blower suitable for 5.5 AC plantall as specified and directed by Engineer-in-Charge.Make Blue star. |
| 17 | Supply and fixing in replacement of Non Woven Polyster Media Enclosed by HDPE mesh Filter suitable for 5.5 AC plant all as specified and directed by Engineer-in-Charge.Make Blue star. |
| 18 | Supply only Refrigerant R-22 refrigerant gas. (Note :- Charges for gas charging shall be paid in respective AMC item No.1 & 13.00 of Sch A ) |
| 19 | Taking down carefully existing storage type geyser 25/50 ltr capacity and disconnection of inlet and outlet water connection taking out all accessories inside the body removing nut bolt from base plate assembly cleaning of inside of stainless steel/copper tank with the help of brush, checking any leakage testing of each unserviceable parts/spairs for its functioning and replacement of unserviceable parts, re fixing the same after cleaning and making proper functioning to maintain proper water temperature, complete all as specified and directed by Engineer-in-Charge.Note: (i) The accessories/spare parts which are required to be replaced shall be measured and paid for separately as \"Supply only\" under respective items of BOQ. |
| 20 | Taking out leakage storage type water heater 25/50 ltr cap dismantling and taking out the inner tank, find out the leakage point brazing the leakage point and replacement of glass wool insulations using glass wool and refixing the same after testing all as directed by Engr-in-Charge. |
| 21 | Supply only heating element of capacity 2/1.5 KW including rubber washer, bolts, clamps etc for geysers of 50/25 ltr capacity of any type & make complete all as specified and as directed by Engineer-in-charge. |
| 22 | Supply only non return valve brass chromium plated 15mm bore horizontal/vertical type suitable for 25/50 ltr capacity geysers complete all as specified and as directed by Engineer-in-charge.Note : The quoted rate shall deemed to include opening of existing GI fitting and cutting & threading of existing pipe line, if required for fixing new NRV. |
| 23 | Supply only pressure release valve (spring controlled) brass chromium plated for geysers of 25/50 ltr capacity of any make and type complete all as specified and as directed by Engineer-in-charge. |
| 24 | Supply only heavy duty PVC connection 450 mm long suitable for 15 mm bore GI pipe including PTMT nuts on both sides complete all as specified and as directed by Engineer-in-charge. |
| 25 | Supply only base plate assembly consisting of inlet and outlet CP brass pipe, thermostatic, CP brass pipe, drain plug, pressure release valve spring controlled and rubber gasket, bolts, washers etc as per existing pattern suitable for 25/50 ltr capacity geyser complete all as specified and as directed by Engineer-in-charge. |
| 26 | Supply only indicator lamp round/rectangular type as per existing suitable for 25/50 ltr capacity geysers working on 230 volt AC supply complete all as specified and as directed by Engineer-in-charge. |
| 27 | Supply only thermostatic cutout/thermostatic switch (ISI marked) suitable for 25/50 ltr capacity geyser complete all as specified and as directed by Engineer-in-charge. |
| 28 | Supply only outer shell duly spray painted as per existing size and shape made of 20 gauge MS sheet suitable for 25/50 ltr capacity geyser of any make including rubber ring and screws complete all as specified and as directed by Engineer-in-charge. |
| 29 | M&L for preparing surfaces of geyser of capacity of 25/50 Ltrs, making dust free, scratching rust and old paint wherever required with sand paper and wire brush and spray painting with one coat of red oxide & one coat of synthetic enamelled paint of approved shade to ) complete all as specified and directed by Engr-in-charge. |
| 30 | Supply only copper tank of 25/50 ltr capacity geysers as per existing size and shape complete all as specified and as directed by Engineer-in-charge. |
| 31 | Supply only fusible safety brass plug as per existing suitable for 25/50 ltr capacity geysers complete all as specified and as directed by Engineer-in-charge. |
| 32 | S&F in repair 15mm bore stop valve fancy type, chromium plated, cast copper alloy, screwed down, high pressure with crutch or butterfly handle screwed both ends for iron pipe or for unions complete all as specified and as directed by Engineer-in-charge. |
| 33 | M&L for periodical repairs and maintenance of water cooler of cooling capacity upto 40/120/150 ltrs/hrs and storage capacity upto 80/120/150 Ltrs complete with disconnecting the water connection, inserting dead plug, dismalting the fan motor, fan blades, condensor etc. Checking up and rectification of wiring and connections, replacement of necessary parts accessories, cleaning of the cold water tank, piping, refrigerant lines, realigment of the fan coil unit and replacement of drain pipe,descaling with carbon dioxide gas to ensure smooth flow of refrigerant gas and connecting to water supply line testing(nitrogen Testing if required).Note: Equipment shall be serviced once in three months and no repeated maintenace shall be measured. Labour charge for on site repair is deemed to be included in the quoted rate of the job. |
| 34 | M&L for Opening up and disconnecting the defective unserviceable sealed compressor unit of water cooler storage type of any capacity andfixing compressor re-appropriated by the manufactures suitable,including testing(nitrogen Testing),nessessary fittings with existing unit complete all as directed complete all as specified and directed by Engr-in-charge. Make: BLUE STAR /GODREJ/EMERSON COPELAND/KIRLOSKARNote :- This item shall not include the cost of gas and gas charging which shall be measured and paid for separately under respective items.ii) Nitrogen gas and its testing charges are included in this item nothing shall be paid extra in this account. |
| 35 | S&F in replacement of relay suitable for compressor of water cooler with clips, relay cover and screws complete all as specified and directed by Engr-in-charge. |
| 36 | S&F in replacement of OLP suitable for compressor of water cooler with clips, relay cover and screws complete all as specified and directed by Engr-in-charge. |
| 37 | S&F in replacement of starting capacitor 40/60/80 MFD complete all as specified and directed by Engr-in-charge. |
| 38 | S&F in replacement of running capacitor 10/15 MFD complete all as specified and directed by Engr-in-charge |
| 39 | Taking down and dismantling blower motor of water cooler and material and labour for rewinding with supper enamelled copper winding wire as per existing pattern including replacement ofgun metal bushes, shaft, clamps includingtesting and commissioning complete all as specified and directed by Engr-in-charge. |
| 40 | S&F in replacement of fan blade of blower motor made out of aluminum alloy fixed with mild steel chromium plated screw etc complete all as specified and directed by Engr-in-charge. |
| 41 | S&F in replacement of 15 mm bore push type water tap brass chromium plated complete all as specified and directed by Engr-in-charge. |
| 42 | S&F in replacement of PVC flexiblehose pipe, 32mm dia as in connections fixed at one end of waste water trapwith clamp and other end left free to open at appropriate distance complete all as specified and directed by Engr-in-charge. |
| 43 | S&F in replacement of blower motor of capacity (1/32HP) including material and labour for replacement of mild steel clamps, rubber rings & capacitor of complete all as specified and directed by Engr-in-charge. |
| 44 | S&F in replacement of condenser made out of copper tubes of heavy grade of adequate size including necessary screws, brazing to existing gas pipes & testing complete all as specified and directed by Engr-in-charge. |
| 45 | M&L for preparing surfaces of water cooler, making dust free, scratching rust and old paint wherever required with sand paper and wire brush and spray painting with one coat of red oxide & one coat of synthetic enamelled paint of approved shade to water cooler of any capacity complete all as specified and directed by Engr-in-charge. |
| 46 | S&F in replacement of thermostat switch/thermostat suitable for water cooler of any capacity including knob, plate and screws complete all as specified and directed by Engr-in-charge. |
| 47 | S&F in replacement of capillary tube for water cooler of any capacityincluding brazing and connecting with existing system complete all as specified and directed by Engr-in-charge. |
| 48 | S&F in replacement of waste water drain tray for water cooler of any capacityincluding pvc clamp necessary screw and connecting with existing system complete all as specified and directed by Engr-in-charge. |
| 49 | S&F in replacement PVC insulated & PVC sheathedmulti stranded copper conductor cable flexible3 core, 2.5Sqmm complete all as specified. Make:- Polycab/Finolex/Anchor. |
| 50 | M&L for periodical Services of Refrigerator of any capacities complete with dismantling internal and external units into components, cleaning of components fan motor, blower, housing, filters etc. Checking up and rectification to wiring and connections, cleaning and reinsulation of refrigerant lines, replacement of necessary parts and accessories, realligment of the fan coil unit and replacement of drain/ condensate pipe connecting and testing (nitrogen Testing if required), descaling with carbon dioxide gas to ensure smooth flow of refrigerant gas and to make the unit fully working condition complete all as directed by Engineer-in-Charge.Note: Equipment shall be serviced once in three months and no repeated maintenace shall be measured. Labour charge for on site repair is deemed to be included in the quoted rate of the job |
| 51 | M&L for Opening and disconnecting the defective unserviceable sealed compressor unit of refrigerator of any make and type AC 230 volts single phase of capacity 165/175/180/190/280 to 310/320 ltr and supply and fixing compressor re-appropriated by the manufactures suitable,including testing(nitrogen Testing), nessessary fittings with existing unit complete all as directed complete all as specified and directed by Engr-in-charge.Make: BLUE STAR /GODREJ/EMERSON COPELAND/KIRLOSKAR Note:- This item shall not include the cost of gas and gas charging which shall be measured and paid for separately under respective items.ii) Nitrogen gas and its testing charges are included in this item nothing shall be paid extra in this account. |
| 52 | S&F in replacement of relay assembly suitable for 165/180/190/280 to 310/320 litre capacity refrigerator including relay cover, clips and screws complete all as specified and directed by Engr-in-charge. |
| 53 | S&F in replacement of thermostat switch/thermostat suitable for refrigerator capacity 165/180/190/310/320 litre including knob, plate and screws complete all as specified and directed by Engr-in-charge. |
| 54 | S&F in replacement of condenser suitable for 165/180/190/310/320 litre capacity refrigerator made out of mild steel powder coatedtubes of heavy grade of adequate size including necessary mild steel clamps and mild steel CP screws, brazing and connecting to existing gas system complete all as specified and directed by Engr-in-charge. |
| 55 | S&F in replacement of door gasket magnetic type suitable for refrigerator of capacity 165/180/190/310/320 litreincluding strip cover and mild steel CP screws complete all as specified and directed by Engr-in-charge. |
| 56 | S&F in replacement OLP 43/33 suitable for refrigerator 165/180/190/280 to 310/320 ltr complete all as specified and directed by Engr-in-charge. |
| 57 | Supply only in replacement of chiller tray of PVC suitable for refrigerator 165/180/190/280 to 310/320 Ltrs capacity as per existing pattern complete all as specified and directed by Engr-in-charge. |
| 58 | Supply only in replacement of PVC vegetable tray suitable for Refrigerator of capacity 165/180/190/280 to 310/320 Ltrs as per existingpattern complete all as specified and directed by Engr-in-charge. |
| 59 | S&F in replacement of evaporator / freezer cabinet complete with freezer door made out of aluminum tubes of adequate sizefor refrigerator of capacity 165/180/270/310 litre including making connection with old system complete all as specified and directed by Engr-in-charge. |
| 60 | S&F Screw type bulb AC 230 Volt suitable for refrigerator of capacity 165/180/190/280 to 310/320 Ltrs complete all as specified and directed by Engr-in-charge. |
| 61 | S&F in replacement of capillary tube for refrigerator of capacity 165/180/190/280 to 310/320 Ltrsincluding brazing and connecting with existing system complete all as specified and directed by Engr-in-charge. |
| 62 | S&F in replacement of door push button for refrigerator of capacity 165/180/190/280 to 310/320 Ltrs complete all as specified and directed by Engr-in-charge. |
| 63 | S&F in replacement of filter dyer for refrigerator of capacity 165/180/190/280 to 310/320 Ltrs complete all as specified and directed by Engr-in-charge. |
| 64 | S&F in replacement of PCB (printed control board) and sensor complete all as specified and directed. |
| 65 | S&F in replacement freezer compartment including door and accessories for 300 ltrs capacity refrigerator complete all as specified and directed. Make:- Godrej/LG/Whirlpool/Samsung /Kelvinator. |
| 66 | S&F in replacement freezer compartment including door and accessories for 165/175 ltrs capacity refrigerator complete all as specified and directed. Make:- Godrej/LG/Whirlpool/Samsung/Kelvinator. |
| 67 | M&L for periodical Services of Deep Freezer of any capacity complete with dismantling units into components, cleaning of components fan motor. Checking up and rectification to wiring and connections, cleaning and reinsulation of refrigerant lines, replacement of necessary parts and accessories, realligment of the fan coil unit and replacement of drain/ condensate pipe, connecting and testing(nitrogen Testing if required), to make the unit fully working condition complete all as directed by Engineer-in-Charge.Note: Equipment shall be serviced once in three months and no repeated maintenace shall be measured.Labour charge for on site repair is deemed to be included in the quoted rate of the job. |
| 68 | M&L for Opening and Disconnecting the defective unserviceable sealed compressor unit of deep freezer of any make and type, AC 230 volts single phase of any capacity and fixing compressor re-appropriated by the manufactures suitable,includingtesting(nitrogen Testing) ,nessessary fittings with existing unit complete all as directed complete all as specified and directed by Engr-in-charge.Make: BLUE STAR /GODREJ/EMERSON COPELAND/KIRLOSKARNote :- This item shall not include cost of gas and gas charging which shall be measured and paid forseparately under respective item.ii) Nitrogen gas and its testing charges are included in this item nothing shall be paid extra in this account. |
| 69 | S&F in replacement of relay assembly suitable for deep freeze including relay cover, clips and screws complete all as specified and directed by Engr-in-charge. |
| 70 | S&F in replacement of thermostat switch suitable for deep freezeincluding knob, plate and screws complete all as specified and directed by Engr-in-charge. |
| 71 | S&F in replacement of door gasket magnetic type suitable for deep freezeincluding strip cover and mild steel CP screws complete all as specified and directed by Engr-in-charge. |
| 72 | S&F in replacement of OLP suitable for deep freezecomplete all as specified and directed by Engr-in-charge. |
| 73 | S&F as per sample type bulb AC 230 volt suitable for deep freezer all as specified and directed by Engr-in-Charge. |
| 74 | S&F in replacement of blower motor for deep frezeer of existing type and capacity including material and labour for replacement of mild steel clamps, rubber rings & capacitor of complete all as specified and directed by Engr-in-charge. |
| 75 | S&F in replacement of Replacement of filter for deep frezeer ,Complete all as specified and directed. |
| 76 | M&L for periodical services of Split type AC capacity 2/1.5 ton complete with dismantling internal and external units into components, cleaning of components fanc motor, housing, filters etc. Checking up and rectification to wiring and connections, cleaning and reinsulation of refrigerant lines, replacement of necessary parts and accessories, reallignment of the fan coil unit and replacement of drain/condensate pipe, connecting up and testing (nitrogen testing if required) to make the unit fully working condition complete all as specified and directed by Engineer-in-Charge.Make: BLUE STAR /GODREJ/EMERSON COPELAND/KIRLOSKARNote: Equipment shall be serviced once in three months and no repeated maintenace shall be measured. Labour charge for on site repair is deemed to be included in the quoted rate of the job |
| 77 | Dismantling/taking out defective compressor unit and supply and fixing re-appropriated company sealed compressor rotary/reciprocating type of 1/1.5 TR capacity obtained from the factory outlet / authorised dealer under their replacement scheme complete including connecting fitting and fixtures making brazing work and leak test (nitrogen Testing) and recharging refrigerant including solering of copper pipes, replacement of foundation rubber bushes, nuts, bolts etc complete all as specified and directed by Engr-in-charge.Note :- This item shall not include cost of gas and gas charging which shall be measured and paid forseparately under respective items .ii) Nitrogen gas and its testing charges are included in this item nothing shall be paid extra in this account. |
| 78 | All as per srl item No.67 but of capacity 2 Ton Spilt type AC . |
| 79 | S&F in replacement of air filter made out of Jute/PVC suitable for split type AC having capacity 1/1.5/2 ton complete all as specified and directed by Engr-in-charge. |
| 80 | S&F in replacement of running capacitor 36+4,36+6,45+4, 45+6,50±2.5,50±4,55+4, 55+6 MFD complete all as specified and directed by Engr-in-charge. |
| 81 | S&F in replacement of capacitor 4/6 MFD complete all as specified and directed by Engr-in-charge. |
| 82 | S&F in replacement of contactor relay complete all as specified and directed by Engr-in-charge. |
| 83 | S&F of Printed Circuit Board (PCB) plate for Split type AC of any make and type(invertor & non-invertor), of capacity 2TR/1.5/1 TR complete all as specified and directed.(Note:- for invertor type AC PCB of outdoor type shall be measured in this item) |
| 84 | S&F of swing assembly motor as per existing model/make for split type AC 1.5/2/1 TR unit, including rubber bush complete all as specified and directed. |
| 85 | S&F in replacement of blower motor (Evaporator motor) for Split type AC of any make and type including material and labour for replacement of mild steel clamps, rubber rings & capacitor of complete all as specified and directed by Engr-in-charge.Make- CROMPTON/AUE/GE |
| 86 | S&F in replacement copper condenser coil for 2/1.5/1 TR capacity Spilt type AC/window type AC including welding/ brazing of pipe line, charging of refrigerantgas and testing of leakage as required complete all as specified. |
| 87 | S&F in replacement copper cooling coil for 2/1.5/1 TR capacity splittype AC including welding/ brazing of pipe line, charging of refrigerantgas and testing of leakage as required including taking out existing one complete all as specified. |
| 88 | S&F in replacement insulation (closed cell elastomeric insulation in tubing) over copper tubing wherever required using approved material as per manufacturers recommendation complete all as specified and directed. |
| 89 | S&F in replacement of thermostat for 2/1.5/1 TR capacity splittype AC including knob, plate and screws complete all as specified and directed by Engr-in-charge. |
| 90 | S&F in replacement of Indoor blower motor for Split type AC of any make and type including material and labour for replacement of mild steel clamps, rubber rings complete all as specified and directed by Engr-in-charge. |
| 91 | Supply only in replacement Remote control for Split AC of any make and any capacity or as per sample complete all as specified and directed by Engr-in-charge. |
| 92 | S&F in replacement of capillary tube for Spilttype AC including brazing and connecting with existing system complete all as specified and directed by Engr-in-charge. |
| 93 | S&F in replacement copper suction pipe line of size 1/2\" dia and other all as per manufacturers recommendation complete with cutting, brazing work and insulation including fittings required at site complete all as specified and directed by Engineer-in-Charge. |
| 94 | S&F in replacement copper discharge pipe line of size 1/4\" dia and other all as per manufacturers recommendation complete with cutting, brazing work and insulation including fittings required at site complete all as specified and directed by Engineer-in-Charge. |
| 95 | S&F in replacement of housing (outer cover) for Split type AC as per sample. |
| 96 | S&F in replacement of Indoor cabinet for split type AC of any make and any capacity or as per sample. |
| 97 | S&F in replacement of Outdoor cabinet for split type AC of any make and any capacity or as per sample. |
| 98 | S&F in replacement of out door unit wall mount stand of Split AC 1.5/2 ton or as per sample for fixing of equipment on wall.(Note :- Charges for umounting and refixing of outdoor unit is included in this items, nothing shall be extra paid in this account) |
| 99 | M&L charging of Refrigerents/Top up to Split AC/ Window AC up to maintain reqd temperature as per site condition complete all as specified and directed. (Note :- Price of refrigerant gas any type (i.e R-22,R-12, R-410A, 407A etc or as required at site) is included in this item). |
| 100 | M&L charging of Refrigerentsto Water cooler/ Refrigerator/ Deep freezer up to maintain reqd temperature as per site condition complete all as specified and directed.(Note :- Price of refrigerant gas any type (i.e R-134a or as required at site) is included in this item). |
| 101 | Removing the worn out old painted from surface of split unit external, scraping cleaning the old paint and repainting with proper colour as approved on external surface over a coat of red oxide primer by spraying painting all as specified and directed by Engineer-in-Charge. |
| 102 | M&L for Rewinding with super enameled copper winding wire of standarad gauge, blower motor including replacement of ball bearing,insulating material complete for AC 1.5 to 2.0 Toncomplete all as specified and directed.Make : Hindustan/Atlas/CCI. |
| 103 | M&L for Removing the old acoustic padding and supply and fix new acoustic (\"U\" form) padding with all packing material for refrigeranttubingfrom outdoor unitto indoor unitall as specified and directed. |
| 104 | Taking out the old unserviceable PVC drain pipe from wall at any height andincluding its fittings and supply and fix newPVC pipe 25 mm dia, ISI markedincluding bends, tees, elbows, sockets, saddles, etc for condensed water complete all as directed. |
| 105 | Taking out the old unserviceable PVC drain pipe from wall at any height andincluding its fittings and supply and fix newPVC pipe 40 mm dia, ISI markedincluding bends, tees, elbows, sockets, saddles, etc for condensed water complete all as directed. |
| 106 | M&L for Removing old unserviceable 2-3 way refrigerant controlvalve from split air conditioner outdoor unit after evacuatingof refrigrant gas and supply and fix2-3 way valve suitable for split type ACs of capacity upto 2 TR and testing complete all as specified and directed. |
| 107 | Supply fix in repair timer for split air conditioner of any capacity all as specified & directed. Make as per existing |
| 108 | M&L for cutting and taking out the rusted/damaged portion of the sheet metal of Geyser/AC/WATER COOLER /DEEP FREEZER /REFRIGERATOR of any capacity and providing new sheet of exiting gauge including welding/brazing as required and painting with two coat of red oxide primer all as specified and directed by Engineer-in-Charge. |
| 109 | Supply and fix in replacement of wall mounting type AC timer havingDelay Time Facility, Auto & manual switch ,Suitable for window ,splits type AC of capacity 1.5/2 TR.Operating on AC input Supply: 230VAC +/- 15 %, 50Hz. Output: 230V, 25 Amp. Separate for 2 A/Cs having Protections for Over voltage (OV): Cutoff 270 V & Cut in 260 V Under voltage (UV): Cutoff 160 V & Cut in 170 V working for 24 Hours timer in 4 to 8 hours time intervals all as specified and directed by Engineer-in-Charge. |
| 110 | S&F in replacment of 3 way backlite connector of capacity 20Amps all as specified and directed by Engineer-in-Charge. |
| 111 | S&F in replacement MCB 6-32 Amps, Single Pole 240 Volts, 10 KA, ‘C’ Curve, complete all as specified and directed by Engineer-in-charge. |
| 112 | S&F in replacement ofsheet metal plug & socket DB, SP, with a two pin and earth plug with socket,230 Volts with & including one MCB SP ‘C’ Curve 10 kA, 20 Amps complete all as specified and directed by Engineer-in-charge. |
| 113 | S&F in replacement of PVC sheathed cable 3 core copper conductor of size 70/.0076mm, flexible for making connection of Geyser/ Spilt type AC complete all as specified and directed by Engr-in-charge. |
| 114 | S&F in replacement of PVC sheathed cable 4 core copper conductor of size 70/.0076mm, flexible for making connection ofSpilt type AC complete all as specified and directed by Engr-in-charge. |
| 115 | S&F in replacement of plug top 3 pin 5 Amps heavy duty for refrigerator/water cooler complete all as specified and directed by Engr-in-charge. |
| 116 | S&F in replacement of plug top 3 pin 15 amps heavy duty for Geyser & Air Conditioner complete all as specified and directed by Engr-in-charge. |
| 117 | Supply and fixing in replacement of Voltage stabilizer of capacity 5 KVA working range between 170-270V with built in thermal overload protection, high & low votage cutoff, time delay system with accuracy of ± 5% complete all as specified and as directed by Engr-in-charge. |
| 118 | Supply and fixing in replacement of Voltage stabilizer of capacity 4 KVA working range between 170-270V with built in thermal overload protection, high & low votage cutoff, time delay system with accuracy of ± 5% complete all as specified and as directed by Engr-in-charge. |
| 119 | Supply and fixing in replacement of water drain pipe suitable for split AC of any capacity and size as per site requirement complete all as specified and as directed by Engr-in-charge. |
| 120 | M and Lfor dismantling the indoor and outdoor units of Air conditioner Split type completely, reinstalled in new location ,including connection commissioning complete all as directed. |
| 121 | M and Lfor dismantling the indoor and outdoor units of Air conditioner Split type completely, transporting to Workshop for carrying out repairs, transporting back to the site, reinstalling the same on the new /existing location complete all for satisfactory functioning of the equipment all as directed by Egineer-in-Charge.Note:- 1.Spare replaced during the proces of repair shall be measured and paid separetly under relivant item Sch A.2.Rates include the cost of dismantling and transporting the AC to workshop and labour element for carrying out repairs. 3 The decision the Engineer -in -charge shall be final and binding on whether machine is required to be sent to workshop for repair or not. |
| 122 | Supply and fix in replacement of sheet metal enclosureswith two pin and earth plug and socket complete with single pole MCB 20 Amps complete all as specified and directed.Make:- Anchor/Havells/Indo Asian. |
| 123 | Supply and fix in repairMS wall bracket prefabricated, duly paintedsuitable for fixing of out door unit of split type Air Conditioner with necessary nuts, bolts & washers and removing old unserviceable items and making good disturbed surfaces to match with the existing complete all as specified and directed |