Public Works Department-PWD has published Provision For Providing And Laying Of Tactile Path In Corridors And School Campus, Construction Of New Ramp, Stainless Steel Railing, New Cwsn Toilet As Per Requirement, Replacement Of Damaged Water Line By New Gi Pipe, Waterproofing Of Old Building Provi. Submission Date for this Tender is 02-08-2023. GI Pipe Tenders in puram Delhi. Bidders can get complete Tender details and download the document.
Sl. No. | Item Description |
1 | Earth work in excavation by mechanicalmeans (Hydraulic excavator) / manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan), including dressing of sides and ramming of bottoms, for all lift, including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 m. |
2 | All kinds of soil. |
3 | Fillingavailableexcavatedearth (excludingrock)intrenches,plinth.sidesof foundationsetc.inlayersnotexceeding 20cmindepth,consolidatingeach deposited layer by ramming and watering, lead up to 50 m and for all lift |
4 | Surface dressing of the ground including removing vegetation and in- equalities not exceeding 15 cm deep and disposal of rubbish, lead up to 50 m and lift up to 1.5 m. |
5 | All kinds of soil |
6 | Providingandlayinginpositioncementconcreteof specified grade excluding the cost of centering and shuttering - All work up to plinth level : |
7 | 1:2:4 (1 cement : 2 coarse sand (zone-III) derived from natural sources : 4 graded stone aggregate 20 mm nominal size derived from natural sources) |
8 | 1:5:10 (1 cement : 5 coarse sand (zone-III) derived from natural sources : 10 graded stone aggregate 40 mm nominal size derived from natural sources) |
9 | Providing and laying damp-proof course 50mm thick with cement concrete 1:2:4 (1 cement : 2 coarse sand (zone-III) derived from natural sources : 4 graded stone aggregate 20mm nominal size derived from natural sources). |
10 | Making plinth protection 50mm thick of cement concrete 1:3:6 (1 cement : 3 coarse sand (zone-III) derived from natural sources : 6 graded stone aggregate 20 mm nominal size derived from natural sources) over 75mm thick bed of dry brick ballast 40 mm nominal size, well rammed and consolidated and grouted with fine sand, including necessary excavation, levelling & dressing & finishing the top smooth. |
11 | Reinforced cement concrete work in beams, suspended foors, roofshavingslopeupto 15*landings,balconies,shelves, chajjas, lintels, bands, plain window sills, staircases and spiral stair cases above plinth level up to foor five level, excluding the cost of centering, shuttering, finishing and reinforcement with 1:1.5:3 (1 cement : 1.5 coarse sand(zone-III) derived from natural sources: 3 graded stone aggregate 20 mm nominal size derived from natural sources). |
12 | Centering and shuttering including strutting, propping etc. and removal of form for |
13 | Shelves (Cast in situ) |
14 | Edges of slabs and breaks in floors and walls |
15 | Under 20 cm wide |
16 | Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete above plinth level. |
17 | Thermo-Mechanically Treated bars of grade Fe-500D or more. |
18 | Brick work with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in foundation and plinth in: |
19 | Cement mortar 1:6 (1 cement : 6 coarse sand) |
20 | Brick work with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in superstructure above plinth levelup to floor V level in all shapes and sizes in : |
21 | Cement mortar 1:6(1 cement: 6 coarse sand) |
22 | Half brick masonry with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in superstructure above plinth level up to floor V level. |
23 | Cement mortar 1:4 (1 cement :4 coarse sand) |
24 | Providing and fixing 18 mm thick gang saw cut, mirror polished, premoulded and prepolished, machine cut for kitchen platforms, vanitycounters,windowsills,faciasandsimilarlocationsof required size, approved shade, colour and texture laid over 20 mm thick base cement mortar 1:4 (1 cement : 4 coarse sand), joints treated with white cement, mixed with matching pigment, epoxy touch ups, including rubbing, curing, moulding and polishing of edges to give high gloss finish etc. complete at all levels. |
25 | Granite stone slab of colour black, Cherry/Ruby red |
26 | Area of slab over 0.50 sqm |
27 | Providing and fixing Ist quality ceramic glazed wall tiles conforming to IS: 15622 (thickness to be specified by the manufacturer), of approved make, in all colours, shades except burgundy, bottle green, black of any size as approved by Engineer-in-Charge, in skirting, risers of steps and dados, over 12 mm thick bed of cement mortar 1:3 (1 cement : 3 coarse sand) and jointing with grey cement slurry @ 3.3kg per sqm, including pointing in white cement mixed with pigment of matching shade complete. |
28 | Providing and fixing aluminium sliding door bolts, ISI marked anodised (anodic coating not less than grade AC 10 as per IS : 1868), transparent or dyed to required colour or shade, with nuts and screws etc. complete : |
29 | 300x16 mm |
30 | 250x16 mm |
31 | Providing and fixing aluminium tower bolts, ISI marked, anodised (anodic coating not less than grade AC 10 as per IS : 1868 ) transparent or dyed to required colour or shade, with necessary screws etc. complete : |
32 | 300x10 mm |
33 | Providing and fixing aluminium handles, ISI marked, anodised (anodic coating not less than grade AC 10 as per IS : 1868) transparent or dyed to required colour or shade, with necessary screws etc. complete : |
34 | 100 mm |
35 | Providing and fixing Fiber Glass Reinforced plastic (FRP) Door Frames of cross-section 90 mm x 45 mm having single rebate of 32 mm x 15 mm to receive shutter of 30 mm thickness. The laminate shall be moulded with fire resistant grade unsaturated polyester resin and chopped mat. Door frame laminate shall be 2mm thick and shall be filled with suitable wooden block in all the three legs. The frame shall be covered with fiber glass from all sides. M.S. stay shall be provided at the bottom to steady the frame. |
36 | Providing and fixing to existing door frames. |
37 | 30 mm thick Glass Fibre Reinforced Plastic (FRP) panelled door shutter of required colour and approved brand and manufacture, made with fire - retardant grade unsaturated polyester resin, moulded to 3 mm thick FRP laminate for forming hollow rails and styles, with wooden frame and suitable blocks of seasoned wood inside at required places for fixing of fittings, cast monolithically with 5 mm thick FRP laminate for panels conforming to IS: 14856, including fixing to frames. |
38 | Structural steel work in single section, fixed with or without connecting plate, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer all complete. |
39 | Structural steel work riveted, bolted or welded in built up sections, trusses and framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer all complete. |
40 | Providing and fixing 1mm thick M.S. sheet door with frame of 40x40x6 mm angle iron and 3 mm M.S. gusset plates at the junctions and corners, all necessary fittings complete, including applying a priming coat of approved steel primer. |
41 | Using M.S. angels 40x40x6 mm for diagonal braces |
42 | Steel work in built up tubular (round, square or rectangular hollow tubesetc.)trussesetc.,includingcutting,hoisting,fixingin position and applying a priming coat of approved steel primer, including welding andbolted withspecial shaped washers etc. complete. |
43 | Hot finished welded type tubes |
44 | Providing and fixing stainless steel ( Grade 304) railing made of Hollow tubes, channels, plates etc., including welding, grinding, buffing, polishing and making curvature (wherever required) and fitting the same with necessary stainless steel nuts and bolts complete, i/c fixing the railing with necessary accessories & stainless steel dash fasteners , stainless steel bolts etc., of required size, on the top of the floor or the side of waist slab with suitable arrangement as per approval of Engineer-in- charge, (for payment purpose only weight of stainless steel members shall be considered excluding fixing accessories such as nuts, bolts, fasteners etc.). |
45 | Precast terrazo tiles 22 mm thick with graded marble chips of size upto 12 mm, laid in foors, and landings, jointed with neat cement slurry mixed with pigment to match the shade of the tiles, including rubbing and polishing complete, on 20 mm thick bed of cement mortar 1:4 (1 cement:4 coarse sand) : |
46 | Dark shade pigment using ordinary cement |
47 | Chequerred precast cement concrete tiles 22 mm thick in footpath & courtyard, jointed with neat cement slurry mixed with pigment to match the shade of tiles, including rubbing and cleaning etc. complete, on 20 mm thick bed of cement mortar 1:4 (1 cement: 4 coarse sand). |
48 | Dark shade pigment using ordinary cement |
49 | Providing and laying Ceramic glazed floor tiles of size 300x300 mm (thickness to be specified by the manufacturer) of 1st quality conforming to IS : 15622 of approved make in colours such as White, Ivory, Grey, Fume Red Brown, laid on 20 mm thick cement mortar 1:4 (1 Cement : 4 Coarse sand), Jointing with grey cement slurry @ 3.3 kg/sqm including pointing the joints with white cement and matching pigment etc., complete. |
50 | Making khurras 45x45 cm with average minimum thickness of 5 cm cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate of 20 mm nominal size) over P.V.C. sheet 1 m x1 m x 400 micron, finished with 12 mm cement plaster 1:3 (1 cement : 3 coarse sand) and a coat of neat cement, rounding the edges and making and finishing the outlet complete. |
51 | Providing sand stone slab for roofing and laying them in cement mortar 1 : 4 (1 cement : 4 coarse sand) over wooden karries or R.C.C. battens or structural steel sections (Karries or battens or structural steel sections to be paid separately), including pointing the ceiling joints with cement mortar 1:3 (1 cement : 3 fine sand ) complete : |
52 | Red sand stone slab |
53 | 40 to 50 mm thick |
54 | Providing and fixing on wall face unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion, (i) Single socketed pipes. |
55 | 110 mm diameter |
56 | Providing and fixing onwall face unplasticised - PVC moulded fittings/ accessories for unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion. |
57 | Bend 87.5" |
58 | 110 mm bend |
59 | Providingandfixingunplasticised PVCpipeclipsof approved design to unplasticised - PVC rain water pipes by means of 50x50x50 mmhard wood plugs,screwed with M.S. screws of required length, including cutting brick work and fixing in cement mortar 1:4 (1 cement: 4 coarse sand) and making good the wall etc. complete. |
60 | 110 mm |
61 | Providing and Fixing 15 mm thick densified tegular edged eco friendly light weight calcium silicate false ceiling tiles of approved texture of size 595 x 595 mm in true horizontal level, suspended on inter locking metal grid of hot dipped galvanised steel sections (galvanising @ 120 grams per sqm including both side) consisting of main ‘T’ runner suitably spaced at joints to get required length and of size 24x38 mm made from 0.33 mm thick (minimum) sheet, spaced 1200 mm centre to centre, and cross “T” of size 24x28 mm made out of 0.33 mm (Minimum) sheet, 1200 mm long spaced between main’T’ at 600 mm centre to centre to form a grid of 1200x600 mm and secondary cross ‘T’ of length 600 mm and size 24 x28 mm made of 0.33 mm thick (Minimum) sheet to be inter locked at middle of the 1200x 600 mm panel to from grid of size 600x600 mm, resting on periphery walls /partitions on a Perimeter wall angle pre-coated steel of size(24x24X3000 mm made of 0.40 mm thick (minimum) sheet with the help of rawl plugs at 450 mm centre to centre with 25 mm long dry wall screws @ 230 mm interval and laying 15 mm thick densified edges calicum silicate ceiling tiles of approved texture in the grid, including, cutting/ making opening for services like diffusers, grills, light fittings, fixtures, smoke detectors etc., wherever required. Main ‘T’ runners to be suspended from ceiling using G.I. slotted cleats of size 25x35x1.6 mm fixed to ceiling with 12.5 mm dia and 50 mm long dash fasteners, 4 mm G.I. adjustable rods with galvanised steel level clips of size 85 x 30 x 0.8 mm, spaced at 1200 mm centre to centre along main ‘T’, bottom exposed with 24 mm of all Tsections shall be pre-painted with polyster baked paint, for all heights, as per specifications, drawings and as directed by Engineer-in-Charge. Note :- Only calcium silicate false ceiling area will be measured from wall to wall. No deduction shall be made for exposed frames/opening (cut outs) having area less than 0.30 sqm.The calcium silicate ceiling tile shall have NRC value of 0.50 (Minimum), light reflection > 85%, non- combustible as per B.S. 476 part IV, 100% humidity resistance and also having thermal conductivity <0.043 w/mK. |
62 | 12 mm cement plaster of mix : |
63 | 1:6 (1 cement: 6 fine sand) |
64 | 15 mm cement plaster on the rough side of single or half brick wall of mix : |
65 | 1:6 (1 cement: 6 fine sand) |
66 | Distemperingwith 1stqualityacrylicdistemper (ready mixed)havingVOCcontentlessthan50gram/litre,of approved manufacturer, of required shade and colour all complete: |
67 | New work (two or more coats) over and including water thinnableprimingcoat withcement primerhavingVOC content less than50 pram/litre |
68 | Finishing walls with Acrylic Smooth exterior paint of required shade . |
69 | New work (Two or more coat applied @ 1.67 ILO 0 sqm over and including priming coat of exterior primer applied @ 0.90 litre/10 sarM |
70 | Painting with synthetic enamel paint of approved brand and manufacture to give an even shade : |
71 | Two or more coats on new work |
72 | Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete. |
73 | Demolishing cement concretemanually/ bymechanicalmeans includingdisposalofmaterialwithin 50metresleadasper direction of Engineer - in - charge. |
74 | Nominal concrete 1:3:6 or richer mix (i/c equivalent design mix) |
75 | Demolishing brick work manually/ by mechanical means including stacking of serviceable material and disposal of unserviceable material within 50 metres lead as per direction of Engineer-in-charge. |
76 | In cement mortar |
77 | Dismantling doors, windows and clerestory windows (steel or wood) shutter including chowkhats, architrave, holdfasts etc. complete and stacking within 50 metres lead : |
78 | Of area 3 sq. metres and below |
79 | Dismantling tile work in floors and roofs laid in cement mortar including stacking material within 50 metres lead. |
80 | For thickness of tiles 10 mm to 25 mm |
81 | Dismantling stone slab flooring laid in cement mortar including stacking of serviceable material and disposal of unserviceable material within 50 metres lead. |
82 | Dismantling G.I. pipes (external work) including excavation and refilling trenches after taking out the pipes, manually/ by mechanical means including stacking of pipes within 50 metres lead as per direction of Engineer-in-charge : |
83 | Above 40 mm nominal bore |
84 | Dismantling old plaster or skirting raking out joints and cleaning the surface for plaster including disposal of rubbish to the dumping ground within 50 metres lead. |
85 | Disposalofbuildingrubbish /malba /similarunserviceable, dismantled or waste materials by mechanical means, including loading, transporting, unloading to approved municipal dumping ground or as approved by Engineer-in-charge, beyond SO m initial lead, for all leads including all lifts involved. |
86 | Taking out existing CC interlocking paver blocks from footpath/ centralverge, including removal of rubbish etc., disposal of unserviceablematerial to the dumping ground, for which payment shall be madeseparately and stacking of serviceable material within 50 metre leadas per direction of Engineer-in-Charge. |
87 | Providing and laying tactile tile (for vision impaired persons as perstandards) of size 300x300x9.8mm having with water absorption lessthan 0.5% and conforming to IS:15622 of approved make in all coloursand shades in for outdoor floors such as footpath, court yard, multimodals location etc., laid on 20mm thick base of cement mortar 1:4(1 cement : 4 coarse sand) in all shapes & patterns including groutingthe joints with white cement mixed with matching pigments etc.complete as per direction of Engineer-in-Charge. |
88 | Providing and laying factory made chamfered edge Cement Concretepaver blocks in footpath, parks, lawns, drive ways or light trafficparking etc, of required strength, thickness & size/ shape, made bytable vibratory method using PU mould, laid in required colour &pattern over 50mm thick compacted bed ofsand, compacting andproper embedding/laying of inter locking paver blocks into the sandbedding layer through vibratory compaction by using plate vibrator,filling the joints with sand and cutting of paver blocks as per requiredsize and pattern, finishing and sweeping extra sand. complete all asper direction of Engineer-in-Charge. |
89 | 60mm thick cement concrete paver block of M-35 gradewith approved colour, design & pattern. |
90 | Providing and fixing white vitreous china pedestal type water closet(European type W.C. pan) with seat and lid, 10 litre low level whiteP.V.C. flushing cistern, including flush pipe, with manually controlleddevice (handle lever), conforming to IS : 7231, with all fittings andfixtures complete, including cutting and making good the walls andfloors wherever required : |
91 | W.C. pan with ISI marked white solid plastic seat and lid |
92 | Providing and fixing white vitreous china flat back half stall urinal ofsize 580x380x350 mm with white PVC automatic flushing cistern,with fittings, standard size C.P. brass flush pipe, spreaders withunions and clamps (all in C.P. brass) with waste fitting as per IS :2556, C.I. trap with outlet grating and other couplings in C.P. brass,including painting of fittings and cutting and making good the wallsand floors wherever required : |
93 | Range of four half stall urinals with 10 litre P.V.C.automatic flushing cistern |
94 | Providing and fixing wash basin with C.I. brackets, 15 mm C.P. brasspillar taps, 32 mm C.P. brass waste of standard pattern, includingpainting of fittings and brackets, cutting and making good the wallswherever require: |
95 | White Vitreous China Wash basin size 630x450 mmwith a pair of 15 mm C.P. brass pillar taps |
96 | Providing and fixing 8 mm dia C.P. / S.S. Jet with flexible tube upto1 metre long with S.S. triangular plate to Eureopean type W.C. ofquality and make as approved by Engineer - in - charge. |
97 | Providing and fixing P.V.C. waste pipe for sink or wash basin includingP.V.C. waste fittings complete. |
98 | Flexible pipe |
99 | 32 mm dia |
100 | Providing and fixing 600x450 mm beveled edge mirror of superiorglass (of approved quality) complete with 6 mm thick hard boardground fixed to wooden cleats with C.P. brass screws and washerscomplete. |
101 | Providing and fixing soil, waste and vent pipes : |
102 | 100 mm dia |
103 | Centrifugally cast (spun) iron socket &spigot (S&S) pipe as per IS: 3989 |
104 | Providing and filling the joints with spun yarn, cement slurry andcement mortar 1:2 ( 1 cement : 2 fine sand) in S.C.I./ C.I. Pipes : |
105 | 75 mm dia pipe |
106 | Providing and fixing bend of required degree with access door, insertionrubber washer 3 mm thick, bolts and nuts complete. |
107 | 100 mm dia |
108 | Sand cast iron S&S as per IS - 3989 |
109 | Providing and fixing plain bend of required degree. |
110 | 100 mm dia |
111 | Sand cast iron S&S as per IS : 3989 |
112 | Providing and fixing single equal plain junction of required degreewith access door, insertion rubber washer 3 mm thick, bolts andnuts complete. |
113 | 100x100x100 mm |
114 | Sand cast iron S&S as per IS - 1729 |
115 | Providingandfixing trapof self cleansingdesign with screwed down or hinged grating with or without vent arm. complete, including cost of cutting and making good the walls and floors: |
116 | 100 mm inlet and 100 mm outlet |
117 | Sand cast iron S&S as per IS: 3989 |
118 | Providing and fixing PTMT liquid soap container 109 mm wide, 125 mm high and 112 mm distance from wall of standard shape with bracket of thesamematerials withsnap fittingsof approved quality and colour, weighing not less than 105 gms. |
119 | Providing and fixing PTMT towel ring trapezoidal shape 215 mm long,200 mm wide with minimum distances of 37 mm from wall face withconcealed fittings arrangement of approved quality and colour,weighing not less than 88 gms. |
120 | Providing and fixing G.I. pipes complete with G.I. fittings and clamps, i/c cutting and making good the walls etc. Internal work - Exposed on wall |
121 | 20 mm dia nominal bore |
122 | 25 mm dia nominal bore |
123 | Providing and fixing G.I. Pipes complete with G.I. fittings and clamps, i/c making good the walls etc. concealed pipe, including painting with anti corrosive bitumastic paint, cutting chases and making good the wall : |
124 | 15 mm dia nominal bore |
125 | 20 mm dia nominal bore |
126 | Providing and fixing G.I. pipes complete with G.I. fittings including trenching and refilling etc. External work |
127 | 50 mm dia nominal bore |
128 | Making connection of G.I. distribution branch with Cl. main of following sizes by providing and fixing tee, including cutting and threading the pipe etc. complete: |
129 | 25 to 40 mm nominal bore |
130 | Providing and fixing brass bib cock of approved quality : |
131 | 15 mm nominal bore |
132 | Providing and fixing brass stop cock of approved quality : |
133 | 15 mm nominal bore |
134 | Providing and fixing gun metal gate valve with C.I. wheel of approved quality (screwed end) : |
135 | 20 mm nominal bore |
136 | Providing and fixing ball valve (brass) of approved quality, High or low pressure, with plastic floats complete : |
137 | 20 mm nominal bore |
138 | Painting G.I. pipes and fittings with two coats of anti-corrosive bitumastic paint of approved quality : |
139 | 50 mm diameter pipe |
140 | Providing and filling sand of grading zone V or coarser grade, allround the G.I. pipes in external work : |
141 | 50 mm diameter pipe |
142 | Providing and fixing G.I. Union in G.I. pipe including cutting and threading the pipe and making long screws etc. complete (New work): |
143 | 15 mm nominal bore |
144 | 20 mm nominal bore |
145 | 25 mm nominal bore |
146 | Providing and placing on terrace (at all floor levels) polyethylene water storage tank, IS : 12701 marked, with cover and suitable locking arrangement and making necessary holes for inlet, outlet and overflow pipes but without fittings and the base support for tank. |
147 | Providing and fixing C.P. brass long body bib cock of approved quality conforming to IS standards and weighing not less than 690 gms. |
148 | 15 mm nominal bore |
149 | Providing and fixing C.P. brass angle valve for basin mixer and geyser points of approved quality conforming to IS:8931 |
150 | 15mm nominal bore |
151 | Providing and fixing PTMT grating of approved quality and colour. |
152 | Circular type |
153 | 100 mm nominal dia |
154 | Providing and laying non-pressure NP2 class (light duty) R.C.C. pipes with collars jointed with stiff mixture of cement mortar in the proportion of 1:2 (1 cement : 2 fine sand) including testing of joints etc. complete : |
155 | 100 mm dia. R.C.C. pipe |
156 | Constructing brick masonry manhole in cement mortar 1:4 ( 1 cement : 4 coarse sand ) with R.C.C. top slab with 1:1.5:3 mix (1 cement : 1.5 coarse sand (zone-Ill) : 3 graded stone aggregate 20 mm nominal size), foundation concrete 1:4:8 mix (1 cement : 4 coarse sand (zone-Ill) : 8 graded stone aggregate 40 mm nominal size), inside plastering 12 mm thick with cement mortar 1:3 (1 cement:3coarsesand)finishedwithfloating coat of neat cement and making channels in cement concrete 1:2:4(1 cement 7 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) finished with a floating coat of neat cement complete as per standard design 7 |
157 | Inside size 90x80 cm and 45 cm deep including C.I. cover with frame (light duty) 455x610 mm internal dimensions, total weight of cover and frame to be not less than 38 kg (weight of cover 23 kg and weight of frame 15 kg) : |
158 | With common burntclay F.P.S. (non modular)bricks of Class designation 7.5 |
159 | Providing and fxing aluminium work for doors, windows, ventilators and partitions with extruded built up standard tubular sections/appropriate Z sections and other sections of approved make conforming to IS: 733 and IS: 1285, fixing with dash fasteners of required dia and size, including necessary filling up the gaps at junctions, i.e. at top, bottomandsideswithrequiredEPDMrubber/ neoprene gasket etc. Aluminium sections shall be smooth, rustfree, straight, mitred and jointed mechanically wherever required including cleat angle, Aluminium snap beading for glazing I paneling, C.P. brass / stainless steel screws, all complete as per architectural drawings and the directions of Engineer-in-charge. (Glazing, paneling and dash fasteners to be paid for separately) : |
160 | Forshuttersof doors,windows&ventilatorsincluding providing and fxing hinges/ pivots and making provision for fixing of fittings wherever required including the cost of EPDM rubber / neoprene gasket required (Fittings shall be paid for separately) |
161 | Powder coated aluminium (minimum thickness of pqwder coating 50 micron) |
162 | Providing and fixing 12 mm thick prelaminated particle board flat pressed three layer or graded wood particle board conforming to IS: 12823 Grade l Type ll, in panelling fixed in aluminum doors, windows shutters and partition frames with C.P. brass / stainless steel screws etc. complete as per architectural drawings and directions of engineer-in-charge. |
163 | Pre-laminated particle board with decorative lamination on both sides |
164 | Grading roof for water proofing treatment with |
165 | Cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20mm nominal size) |
166 | Providing and fixing Retro-reflective regulatory sign board of size 900 mm dia meter made out of 2 mm thick aluminium sheet, face to be fully covered with high intensity ncapsulated lens type retro -reflective sheeting as approved by Engineer-in-charge . Letter, symbols, borders etc. will be as per IRC - 67 with required colour scheme n the boards and with the high intensity grade A. complete in all respects as per direction of Engineer-in-charge. |
167 | Providing and fixing 10mm thick clear or in required colour blue, brown or green etc. poly carbonate multi walled sheet of brand as approved by Engineer- in-Charge. The multi walled poly carbonate sheet shall be fixed on tubular steel structure with 25 micron thick powder coated aluminium strip of size 40x2 mm and weather proof Neoprin EPDM rubber gasket on both side of joints, top and bottom, so as to make the whole structure water tight as per approved design/drawings. The aluminium section shall be fixed on joints and both end of poly carbonate sheet to fix the sheet rigidly on steel frame structure. The weather proof neoprene and aluminium profile shall be fixed and sealed with silicon scalent to make the joints fully water proof. The poly carbonate sheet and profile shall be fixed with self taping and self drilling 50mm long steel screws fixed not less than 150mm center to centre. The rates are be inclusive of cost of all material involved such as poly carbonate sheet,aluminium profile channel, EPDM gasket, self taping screws, nut bolts, silicon sealant or any other material requiredfor fixing the sheet but excluding the cost of steel structure which shall be paid for separately. The cost also include the rate of labour required for cutting, bending and fixing of poly carbonate sheet aluminium profile, hoisting in position etc. complete as per direction of Engineer in Charge. (End to endFinished curved surface area of poly carbonate sheet fixed over steel tubular structure shall be measured for the purpose of the payment). |
168 | Renewing glass panes/transclucent white acrylic plastic sheet with putty and nails wherever necessary including racking out the old putty: |
169 | Float transclucent white acrylic plastic sheet of thickness 4 mm |
170 | Cutting Marble/Sand Stone/Kota Stone/Granite Slabs up to 50 mm thick by mechanical device and dismantling existing Marble/Sand Stone/Kota Stone/Granite Slabs laid in cement mortar including stacking of serviceable material and disposal of unserviceable material within 50 metres lead. |
171 | Design, Supply and fixing of Acrylic multilingual Braille Tactile signages -like building entrance, door signages, name plates, (raised domes) signboards of minimum size 9"x6" (225x150mm) to for doors, specific areas like toilets, water etc & directions (without maps or drawings), designed as per the drawings issued and having 3+2mm thick blue Acrylic non glare base plate, and 0.5mm thick aluminium plate at backside, with upper case san serif words, with upper case san serif words made of white acrylic non glare cut out letters of height 15mm raised 0.8mm above base plate and the equivalent word/s written in Hindi with Devnagri non glare acrylic letters of height 15mm raised 0.8mm above base plate. Signage to have a relevant symbol made of white cut out acrylic and raised by 0.8mm above base plate, Grade 1 Braille consisting of raised domes of 1.5 to 1.6mm dia. and spacing as per Braille standards given by GOI to be integral with the sign face and be raised 0.6 to 0.9mm above base plate. Each signboard to be fixed as per manufacturers specifications at the specified locations at a height of 1200mm from FFL and up to the satisfaction of the engineer in charge. (These rates for all sizes specific to sizes from 22.5cmx15cm upto or below of 60cmx60cm maximum dimensions, in two colour scheme only). |
172 | Providing and fixing vinyl floor marking tape, colour contrasting strip 75mmx5mm thick of approved make complete as per direction of Engineer in charge. |
173 | Credit to work on account of taking away the dismanlted material from site as per direction of Engineer in Charge i.e. Bars, Z-section, Rolled steel sections, Structural Steel section, G.I. barbed wire, Expended metal/IRC fabric, CI/SCI pipes of various diameter, GI pipes of various diameter, CI pipes of various diameter (Broken in pieces), CI Manhole cover & frames( Broken in pieces) CI, DI, LA, etc. |
Copyright © 2024 · All Rights Reserved. Terms of Usage | Privacy Policy