Tender For Providing Pumping Main Line ( 1350 ) M And Pump Room And Motor Accesseriesinmelakondai Panchayat ; 2 Pumping Main Line 3 Supply, Delivery, Laying And Jointing Of 90Mm Od Pvc 6Ksc Pipe Inlcuding Earth Work Excavation In All Strata Soil, Refilling And Hydraulic Testing, Adopting Standard Specification And As Directed By Twad Board Officer. 4 A.90Mm Pvc Bend 5 B 90Mm Pvc Threaded Coupler 6 Lab Testing Charges 7 Motor Accesseries 8 Supply, Delivery And Erection Of Submersible Pumpset Of50 Lpmx 175 Head As Per Sor Twad - Page 88 9 Supply And Delivery Of 3 Phase Panel Board D.O.L With Two Level Guard And Auto Start Confirming To Is Specification For 5 Hp Pumpset.Twad Sor Page 101 10 Supply, Delivery Of 1.1 Kv Grade, Pvc Insulated And Sheathed3 Core Flat Copper Submersible Cable With Isi Marking Conforming Of Is 694 / 1990 Of Reputed Make For Submersible Motor Erected In Borewell. 11 Supply And Delivery Of Ms Kiosk Of Size0.75M X 0.45M X 0.75M Made Up Of Msangle Of Size 50Mm X 50Mmx 4Mm Alroundcovered With 16 Gauge Ms Sheet And Kioskdoor Made Up Of Ms Plates Of Size 25 Mm X3 Mm Including Cutting, Welding, Grinding, Locking Arrangements And Labour Charges 12 50Mm Upvc Column Pipe 13 40Mm Gi Coupling Heavy Page 29 14 40Mm Gi Bend Heavy Page 29 15 50Mm Gi Flangeset Heavy Page 29 16 40Mm Ms Clampset Heavy Page 29 17 50Mm Gm Non Return Valve Page 30 18 50 X 40Mm Gi Reducer Heavy Page 26 19 63Mx50mmpvc T.Coupler Page 10 20 40Mm Ball Valve / Gm Gate Valve Page 30 21 ( I ) Aerial Fuse Board Of Size 15 X 10 X 6Cmwith 32 A Aerial Fuse Carrier ( 3 Nos. ) 22 ( Iii ) Wall Mounting Type Ms Cubical Eb Meter Box With Fuse Carrier ( 3 Nos ) Of 32 A Capacity At Eb Supply Point.This Box Is Also To Accommodate Tneb Energy Meter With Proper Ventilation As Approved By Tneb. 23 ( Ii ) Supply And Laying Of 7 / 20 Size Pvc Insulator Copper Conductor Cable From Aerial Fuse To Eb Supply Point Etc., Complete As Per I.E Rules. 24 25Mm Dia Gi Pipe For Service Point 25 25Mm Dia Gi Elbow 26 No.8 Gi Wire For Earth ( Twin Earthing ) 27 Stay Wire 7 / 20 28 20Mm Gi Pipe For Twin Earthing And Cable Encasing 29 4Way Nutral Link 30 Tw Banel Board ( 41 X 31 X 6Cm ) 31 Labour Charges For Erection Of Submersible Pump Set Including Fixing And Jointing The Submersible Cable With Clamps To The Required Depth, Valves And Errection Panel Board Control Room Twin Earthing As Per I.E Rules Including Cost Of Civil Works Upto 5 Hp 32 Construction Of Bore Pit Arrangements Complete Ect. 33 Pump Room 34 Earth Work Excavation & Depositing On Bankwith An Initial Lead Of 10 Metre & Initial Lift Of 2 Metre In Hard Shift Clay, Stiff Block Cotton, Hard Red Earth Shales, Murrum, Gravel, Stoney Earth, And Earth Mixed With Small Size Boulders And Hard Gravelly Soil ( Ss 20B ) For Foundation Including Shoring, Strutting, Baling Out Water Providing Danger Light Wherever Necessarydepositing Thesurplus Earth On Bank And Otherincedential Charges Etc., Complete And As Directed By Twad Board Officers 35 Levelling Course With P.C.C 1:4:8 ( One Cement, Four Sand And Eigth Course Aggregate ) Using 40 Mm H.B.G Stone Including Mixing Concrete, Laying, Curing And Compacting Of Concrete Etc., Complete And As Directed By The Twad Board Officers. 36 Earth Filling In Basement & Sides Of Foundation With Excavated Earth Including Ramming And Consolidation Etc., Complete 37 Supply And Filling The Foundation And Basement With Clear River Sand In Layers Complying With Standard Specification Including Consolidation And Watering Etc. Complete And As Directed By Twad Board Officers. 38 Brick Work In Cm 1:5 ( One Cement And Five Sand ) Using Country Bricks Of Size 8.75 X 4.25 X 2.00 Including Cost Of All Materials, Labour Charges, Curing Etc., Complete And As Directed By Twad Board Officers. 39 For Foundation And Basement 40 For Super Structure 41 Reinforced Cement Concrete 1 : 1 1 / 2: 3 ( One Cement, Oneand Half Sand And Three Coarse Aggregate ) Using 20Mm Size Hard Broken Stone Jelly ( Machine Crushed ) For The Following Members.The Rate To Excludethe Cost Of Steel For Reinforcement, Centering, Shuttering, Strutting But Includingcost Of Mixing Of Concrete, Placing, Vibrating With Mechanical Vibrator, Finishingand Curing Etc. Com 42 Reinforced Cement Concrete 1 : 1 1 / 2: 3 ( One Cement, Oneand Half Sand And Three Coarse Aggregate ) Using 20Mm Size Hard Broken Stone Jelly ( Machine Crushed ) For The Following Members.The Rate To Excludethe Cost Of Steel For Reinforcement, Centering, Shuttering, Strutting But Includingcost Of Mixing Of Concrete, Placing, Vibrating With Mechanical Vibrator, Finishingand Curing Etc. Com 43 Plastering With C.M. 1:5 ( One Part Of Cement And Five Parts Of Sand ) With 12Mm Thick Over Brickwork Portion Including Labour Charges For Mixing Finishing And Curing Etc., Complete And As Directed By Twad Board Officers. 44 Steel Centering For Soffits Of Rcc Members Including Shuttering, Strutting To The Centring And Providing Supports Etc.Complete For The Following Members Using Ms Sheets Of Size 90Cm X 60Cm And Bg 10 Gaugesstiffened With Welded Ms Angles Of Size 25 X 25 X3mm Laid Over Silver Oak ( Country Wood ) Joists Of Size 10 X 6.5 Cm ( Spaced At About 90Cm C / C ) And Supported By Casurania Props Of 10 Cmto 13 Cm Dia. Spaced At 75 Cm C / C And As Directed By Twad Board Officers.The Centring Materials Should Be Supplied And Should Be Removed After The Specified Stripping Time Of The Concrete As Per Is 456 / 1978. 45 Special Ceiling Plastering For Rcc Slab With C.M.1:3 ( One Part Of Cement And Three Parts Of Sand ) 10Mm Thickover Rcc Surface Including Labour Charges For Mixing Finishingand Curing Etc., Complete As Directed By Twad Board Officers 46 Flooring In C C 1:4:8 ( One Cement , Four Sand And Eight Hbs ) 10 Cm Thick Using 40Mm Hbs Metal And Top Finished With Cement Mortar 1:3 ( One Cement And Three Sand ) 12 Mm Thick Including Labour Charges For Mixing, Finishing And Curing Etc. Complete And As Directed By Twad Board Officers. 47 Supply And Fixing Of Ms Door ( Single Leaf ) Of Sizes 1.00 X 2.00M In Ms Angle 50 X 50 X 4Mm And Ms Flat 35 X 6Mm With Ms Sheet Of 18 Gauge Including Ventilating Arrangements Using 20Mm Square Ms Rods With Locing Arrangements Including Two Coats Of Approved Enamel Painting Over One Coat Of Primer 48 Supply, Fabricating And Fixing In Position Of Rts Rods Including Cost Of Steel And Binding Wire Etc., Complete. 49 Supply And Fixing Of Rcc Box Type Jolly Of Size 0.6 X 0.45 M 50 Painting Two Coats With Approved Cement Paint Over One Priming Coat Of White Cementover Cement Plastered Wall Surface And Ceiling Including Cleaning Preparing The Surface And Curing Etc., Complete ( Using Cement Paint Of Colour As Approved By The Departm 51 White Washing Two Coats Using Fine Screened Shell Lime For The New Plastered Surface For Inner And Outer Side Of The Room Including The Cost Of Materials Labour Charges Etc., Complete And As Directed By Twad Board Officers. 52 Weathering Coarse Over Rcc Roof Including Fixing One Coarse Of Pressed Tiles Etc., Complete. 53 Provision Of Lock And Key For Pump Room And Oht Ladder 54 Levelling The Site 55 Providingname Board 56 Photo Graphic Charges 57 Gst Amount For Providing Service To Government Contract Works For The Above Construction Works. { Gst Amount Is The Total Gst Amount For Total Overall Quoted Amount Above This Row In Column Bb For All Works In This Package }