Tender For Electrical & Data Cabling Works In New Premises Of Mahoba Branch, District - Mahoba, mahoba-Uttar Pradesh

Indian Bank-IB has published Tender For Electrical & Data Cabling Works In New Premises Of Mahoba Branch, District - Mahoba. Submission Date for this Tender is 07-08-2023. Electrical Maintenance Tenders in mahoba Uttar Pradesh. Bidders can get complete Tender details and download the document.




Tender Notice

38804210
Tender For Electrical & Data Cabling Works In New Premises Of Mahoba Branch, District - Mahoba
Open Tender
Indian
Uttar Pradesh
mahoba
07-08-2023

Tender Details

Tender For Electrical & Data Cabling Works In New Premises Of Mahoba Branch, District - Mahoba 1 ELECTRICAL WIRING & EARTHING 1.1 Supply, laying, connection & testing of light, fan point, wiring by 2 x 1.5 mm sq (2x3/.029) + 1 x 1mmsq PVC insulated, multi-strand single core copper conductor FRLS wire maintaining the color code as per direction in PVC conduit of 20mm with ISI mark 1.5mm thickness to conceal in wall partition mending good the damage, complete with PVC circular box, bend to be done as per drawing including 3 point ceiling rows wherever required GI saddle to be used for fixing, metal flexible/PVC flexible pipe may use if required in partition wall. All PVC pipes should be with ISI mark. No joints will be allowed inside pipe, light, fan & plug point complete with modular type switch plate & MS box rate Including the main circuit line 2 x 2.5mmsq + 1 x 1.5 mm sq earth PVC insulated Cu. Wire from DB to switch board, maintaining the color code. Circuit line for lighting switch board & 6Amps plug board are to be drawn from lighting DB to Lighting board & plug point board (independent ), 6/16 Amps plug point line are to be draw from power DB as per DB schedule /SLD a) 1 light by 1 switch (ATM 1 No),UPS Pt 3 In branch 1 in ATM Nos. 30 b) 2 light by 1 switch Nos. 16 c) 3 light by 1 switch Nos. 6 e) Ceiling fan point with step type electronic regulator No 7 f) Same as above, but for exhaust fan excluding regulator. No 3 g) Same as above 5A Point in the switchboard itself. (for branch 4 No & ATM 1 No) No 10 h) same as above Wiring for call-bell point including buzzer No 1 i) Wiring (2 x 2.5mmsq + 1 x 1.5mmsq from power DBs) for independent 6A multi pin socket at walls along with 6A modular type switches board housed in painted MS box (up to 3 independent plug points can be taken in one circuit). For wall Fan No 12 1.2 Supply and installation of modular type 2 nos 6A & multi pin sockets with 2 nos 6 Amp one way switch housed in MS box to be fixed in partitions or concealed in wall. The box shall be painted with 2 coats of enamel paint over a coat of red oxide primer including wiring for Raw power socket outlet using 2 R runs of 2.50 Sq mm and single run of 1.5 sq mm PVC insulated multi stranded single core copper conductor FRLS wire in 20mm PVC conduit to be laid in floor, partitions, etc. complete with all accessories (looping 2 sets of 2x6A socket outlet in one circuit- from DB) (Raw power) for counter (Each counter 1 Nos +BM :2 Nos, ATM 1No:,Pantry 1No.:) No 10 1.3 Supply and installation modular type 16A, 5-pin socket with 16A one way switch housed in MS box to be fixed in partitions or concealed in wall. The box shall be painted with 2 coats of enamel paint over a coat of red oxide primer, the rate shall include wiring fusing 2R 4.0 sq mm & single run of 2.5 sq mm PVC insulated multi stranded single core copper conductor Nos. 13 FRLS wire in 25mm PVC conduit to be laid in floor, partitions, etc complete with all accessories (for line printer: or optional). (up to 2 independent plug points can be taken in one circuit) C.C:1No. BM.;1 No.: Alternative counter 2No + Banking Hall 1 No+ Pantry 1No, ATM :1No) 1.4 Supply and installation of power supply disconnection arrangement for strong room consisting of 1 no 10A DP MCB housed in manufacturers powder coated MS box to be fixed inside the strong room and connected with 1 no 3-pin metal clad plug with 2 meter long 3 core 2.5 sq mm PVC insulated flexible copper conductor cable. Set 1.00 1.5 ACs electrification (a) Supply and fixing 25 Amps 3-pin modular socket with 25 Amp one way switch with indicator (near AC indoor unit) housed in manufacturers MS powder coated box to be concealed in wall including Wiring using 2R4.0 sq mm & single run of 2.5 sq mm PVC insulated multi stranded single core copper conductor FRLS wire in 25mm PVC conduit to be laid in floor, partitions, etc complete with all accessories. (for split AC units) -(from Stabilizer to IDU)Supply. (2 Nos for ATM), Stabilizer to be installed in the panel room. Nos 7 (b) Supply and fixing 25 Amp - 3 pin metal clad socket with plug controlled by a 25 Amp SP MCB (for Ac wall mounted stabilizers) housed in manufacturers MS powder coated box to be concealed in wall including Wiring using 2R 4.0 sq mm & single run of 2.5 sq mm PVC insulated multi stranded single core copper conductor FRLS wire in 25mm PVC conduit to be laid in floor, partitions, etc complete with all accessories. (for split AC units) from AC DB to Stabilizer (2 Nos for ATM) Nos 7 (c) Supply and fixing 20A 3-pin modular socket with 20A one way switch with indicator (near AC indoor unit) housed in manufacturers MS powder coated box to be concealed in wall including Wiring using 2R 2.5 sq mm & single run of 2.5 sq mm PVC insulated multi stranded single core copper conductor FRLS wire in 25mm PVC conduit to be laid in floor, partitions, etc complete with all accessories. (for split AC units) - (from Stabilizer to IDU) Supply. Stabilizer to be installed in the panel room. Nos 0 (d) Supply and fixing 20A - 3 pin metal clad socket with plug controlled by a 20A SP MCB (for Ac wall mounted stabilizers) housed in manufacturers MS powder coated box to be concealed in wall including Wiring using 2R 2.5 sq mm & single run of 2.5 sq mm PVC insulated multi stranded single core copper conductor FRLS wire in 25mm PVC conduit to be laid in floor, partitions, etc complete with all accessories. (for split AC units) from AC DB to Stabilizer Nos 0 2 LAYING OF CABLE : 2.1 Supply laying fixing main power with 50mm sq 3.5 core PVC insulated, PVC sheated Alu. Conductor, 1100 v. grade armored cable complete with 02 nos 8 SWG bear GI wire as running earth. ( Meter panel to Main Panel & Dgset to Main Panel ) Mts. 40 2.2 End termination of 50mmsq 3.5 Core armored cable, complete with brass cable gland, Alu. Lug, PVC tape. Nos 80 2.3 - Do - 3.5 x 16 sq mm with 02 nos 8 SWG bear GI wire as Mts 50 running earth. for Light D.B 2.4 - Do - 3.5 x 25 sq mm th with 02 nos 8 SWG bear GI wire as running earth. for POWER & A.C D.B , UPS & ATM Mts 40 2.5 - Do - termination of 25 & 16 Sq mm 3.5 Core Nos 8 3 Outdoor type glow sign board wiring :- 3.1 Supply laying of main line with 2x2.5 +1x1.5 mm sq through MS conduit from main panel to glow sign board. Mts 25 3.2 Supply installation of 16 amps DP MCB at main entrance Glow sign board & With Electronic timer as required. Set 1 4 EARTHING STATION : (i) Earthing installation as per I.E. rule conforming Set 2 Supply, Installation, Testing and Commissioning of Maintenance Free Earthing system made up of copper bonded rod of 10 feet length, 23 mm dia. (Minimum copper bonding shall be 0.25mm) along with Rod-to Conductor connectors, Earth enhancement material, Pit Cover and other accessories as required and as per specification and other applicable codes (include chamber for earthing, Earthing certificate to be submitted along with the bill). (ii) Supply laying 2x8SWG copper bear wire from earth spike to main panel. (Electrolyte wire) Mts 20 5 MAIN ELECTRICAL DISTRIBUTION 5.1 S/F of 3 nos. 200Amps Kit kat set link type with heavy duty neutral link and making its connection from electronic meter c/w wooden board etc. Set 1 5.2 Main Panel (wall Mounted Type) Supply, fabricating, assembling, internal- connection, testing & connecting with incoming, outgoing power cables & lines as required completing the job of cubical type electrical panel made from 14SWG CRC. M.S. sheet with proper earthing terminal(Nut- bolt &washer) 02 No. outside of panel, same nut- bolt to tighten with internal earth busbar of panel situated inside loose wire box(on top portion of panel) On top side of panel cable entry arrangement to be done for incoming & outgoing of lines. Painting powder coating electrical grey/ seimens grey to be done. one 6x4 enamel type 440Volt Danger board to fix up on main panel bus-bar cover, components are as follows :-All switches are front handle operated & all MCB knob should be visual, all component to provide in separate compartment only DBs in one compartment. Incomer - 100A 4P MCCB 25Ka with adjustable thermal & Magnetic trip unit -1 Nos OUTGOINGS - 63 Amps 4 pole MCB. = 04 Nos.(AC & Power DB, ATM, UPS, spare ) 40 Amp 4 Pole MCB: 2 nos (Lighting DB, Spare) 25 Amps DP MCB = 02 Nos. (sign board , Fire Alarm) Amps Meter 0-100 Amps with 3 Nos. CT & selector switch 96x96mm 01 Set (Changeover should be ON-LOAD type.) 100Amps 4pole Cu. Bus Bar. 01 Set. 100Amps 4 pole Change over switch. 01 No. 100 Amps FP MCCB 25KA as Gen - Set main incoming 01 NO Volt meter 0-500volt A.C. 50 Hz.96x96mm with selector switch. AE make.n 01 Set 20mm dia LED indicator lamp 03 Nos. 02 Amps Sliding Fuse. 06 Set. 150x100mm enamel Danger board 440 volt. (to set on bus bar cover). 01 No. Cable entry from top & bottom - removable gland plates (bottom at 2 points) c/w powder coated Grey paint (two coats) with name labels for all incoming & outgoing feeders. The panel shall be complete in all respects including all accessories such as earthing bus, Air ventilators, lifting hooks etc. Set 1 5.3 POWER DB & AC DB. Make standard/Legrand/ABB, Double door 6 way TPN MCB DB with TP MCB as incoming 63 TP&N MCB as main 16Amps SP MCB - 8 Nos (Ac: 3 Nos + 2 X 6amp: 4Nos and 1Nos spare) +32AMPS SP X10 NOS. (Ac 3 Nos+15 Amp: 6 Nos, 1No Spare) Including Neutral Bar. 01 Set Set 1 5.4 LIGHTING DB Make standard/Legrand/ABB 6 way TPN MCB DB with TP MCB as incoming 63A TP&N MCB as main 32 AMPS DB MCB 1No: For Strong room ) 16 Amps SP MCB - 03 Nos.+ (BM +Toilet) each 1No + 1No spare 12 Amps SP MCB - 12 Nos. (Hall - 4Nos + Store room 1 No +External Lighting 1No.:+ Ups 1No + wall Fan 3 Nos.2 No spare) Including Neutral Bar. 01 Set Set 1 6 UPS SYSTEM (Branch) 6.1 UPS Main DB Supply, erection, testing and commissioning of three phase 4 WAY, TPN MCB DB double door type with C Curve MCBs, IP 42 powder coated for UPS with 63A 4P MCBs – 1No as INCOMER 32A TP MCBs – 3 Nos. as OUTGOING (UPS: 2Nos and 1 set Spare Including all interconnections & accessories etc Make standard/ Legrand/ ABB Nos 1 6.2 Supply & Fixing of 32A DP MCB in 2way SPN Db IP 20 metallic directly on wall Raw power Incoming & Outgoing supply for UPS (Branch :2 Nos & ATM 1No.) Nos 4 6.3 UPS DB-1 & 2 combined 12 Way SPN MCB DB with C curve MCBs. Incoming: 2 No. 40A DP MCB Outgoing: 8 Nos 6/10A (BM: 1+1 Nos with lighting: Server & Data Rack (1+1) Nos: C.C 2Nos with lighting: counter: 2 Nos) SPO MCBs Make standard/Legrand/ABB. Respective UPS lighting to be connected. (BM, C.C, Banking hall 2Nos) or as per SLD Nos 1 6.4 Supply and installation of modular type 3 nos 6A multi pin sockets with 2 nos 6A one way switch with indicator housed in MS box to be fixed in partitions or concealed in wall. The box shall be painted with 2 coats of enamel paint over a coat of red oxide primer including making connections complete the rate inclusive of Supplying and running of 3 runs of 2.5 sq.mm UPS DBs to individual power station through. (looping 2 sets of Nos 13 3X6 A socket outlet in one circuit / or as per SLD the following size of 660 volts grade, Finolex brand PVC insulated wire (For UPS point only).(For B.M, C.C, Server each 2Nos.) +5 Nos for Counter + Rack 1Nos) 6.5 Supply & Laying of 4 runs of 6.0 Sq mm and 2 runs of 2.5 sq mm, PVC insulated, single core, multi-stranded copper conductor cable in suitable rigid / flexible metal conduit from Main UPS DB to auto phase shifter. mtr 10 6.6 Supply, installation, testing and commissioning of 40A rated 3 phase to single phase auto phase shifter for 3.0 KVA UPS (SLHD of Swift make) Nos 2.00 6.7 Supply & Laying of 2 runs of 6.0 Sq mm and 1 run of 2.5 sq mm, PVC insulated, single core, multi-stranded copper conductor cable in suitable rigid PVC conduit from auto-match phase shifter to UPS unit mtr 10 6.8 Supply and Installation of Moduler type 2 X 20A plug & socket housed in for UPS output control (Branch 2 Nos & ATM 1No.) Nos 3.00 6.9 Supply & Laying of 2 runs of 4.0 Sq mm and 1 run of 2.5 sqmm, PVC insulated, single core, multi-stranded copper conductor cable in suitable rigid / flexible metal conduit from 3 KVA UPS to UPS DB mtr 10 8 ELECTRICAL FITTINGS (S/I/T/C) 8.1 Supply and Installation Recess mounted 2’-0X2-0” watt, 38 W LED FULL GLOW Philips MAKE. Light should be fixed through SS threaded bolt tighted the upper end on ceiling using anchor bolt and lower end on Light fitting with nut and bolt (RC380B G2 LED35S-6500/4000 PSU OD WH) PHILIPS/WIPRO MAKE (ATM 2 No) Nos. 22 8.2 Supply, Installation, testing and commissioning of single colored , 8 meter LED light strip of 5W per meter complete with necessary drivers, all accessories and etc for cove lighting in column paneliling (Bajaj BCFL 300 25W/ Wipro LS 06 005 120/ Philips/Crompton) including connection & mounting arrangement as required w.r.t site conditions.(Fitting and drivers shall be of IP20 protection class) Nos. 0 8.3 SQUARE SHAPE DOWNLIGHTER - INTEGRA 15W, 3000K, LHEBGTP5Z1W015, PHILIPS Razor/WIPRO MAKE (ATM 2NOS) Nos. 32 8.4 TUBELIGHT - LED TUBELIGHT 36 W, PHILIPS/WIPRO MAKE. ATM 1 No Nos 16 8.5 HANGING LIGHT - LHECDOL5PW1W040 (40WATTS), PHILIPS/WIPRO MAKE NOS. 3 8.6 150 mm dia Heavy Duty Exhust fan 230 voltA.C.( Havells / Crompton make).(UPS & Toilet ) Nos 4 8.7 M.S body frame Wall mounting fan 450 mm dia 230 volt A.C. PHILIPS/WIPRO MAKE Nos. 12 8.8 Supply of Ceiling fan with 1200mm sweep, double ball bearing motor, capacitor, three MS blades die cast Al housing in stove enameled white with, suspension rod including all accessories of approved make. (5 star rated) (ORIENT/KHAITAN). (UPS, Strong room & Store room) Nos. 7 TOTAL FOR BRANCH ELECTRICAL WORK (B) 1.0 TELEPHONE SYSTEM 1.1 Wiring for telephone points with 2 pair 4/5 pair .51mm dia ATC (annealed tinned Cu wire) with PVC insulated PVC sheathed telephone cable from tag block to the point including providing ferrules at both ends and termination at both ends including providing & fixing RJ 11 outlet, faceplate and mounting box complete of modular type 9 where 2 such points are shown, 2 such wires shall be provided) This work includes providing PVC conduits in chases from the raceway to the point. (1 each for branch manager, C.C. P. officer & Clerk). separate IO box to be provided for Telephone Nos. 6 1.2 Supplying, laying effecting terminations, testing and commissioning of 0.51mm dia Cu. Conductor, twisted, color coded with polythene capor barrier, telephone cables in the existing tray or in conduit including providing & fixing conduit pipe or cable tray as required from building tag block to the floor as required. a 0.5mm, 5 pair armored telephone cable from telephone connection in the premises to the crone box. rmt 20 b Supplying & fixing 20 pair krone tag block with enclosure. Nos. 1 2.0 DATA SYSTEM - CONDUITING & CABLING 2.2 Wiring for computer networking from I/O hub to computer workstation with UTP Cat-6 computer cable including providing ferrules at both ends and termination at both ends including providing & fixing frame for with shutter, RJ 45 outlet, faceplate and mounting box complete of modular type, This work includes providing PVC conduits (1/2, 3/4 size or as required0 in chases from the I/O hub to the point. The cost includes testing, commissioning etc complete. Note: Do not run more than 3 wires in single pipe & should be concealed. ( Server, BM, CC & ATM each 2Nos and counter 5Nos) Nos. 12 2.3 Supply of Cat - 6 D-Link patch cord 7 0 (ATM 1No) Nos. 12 2.4 Supply of Cat - 6 D-Link patch cord 3 0(ATM 2No) Nos. 12 2.5 Supply & fixing 24 Port Jack Panel Make:-D-Link Nos. 1 2.6 19 Rack 9U with Glass Door , Locking system Make: APW Nos. 1 2.7 24PORT 10/100Mbps Switch Nos. 1 TOTAL FOR BRANCH LAN & TELEPHONE (C) 1 ELECTRICAL WIRING & EARTHING 1.1 Supply, laying, connection & testing of light, fan point, wiring by 2x1.5mmsq(2x3/.029) +1x1mmsq PVC insulated, multi-strand single core copper conductor FRLS wire maintaining the color code as per direction in PVC conduit of 20mm with ISI mark 1.5mm thickness to conceal in wall partition mending good the damage, complete with PVC circular box, bend to be done as per drawing including 3 point ceiling rows wherever required GI saddle to be used for fixing, metal flexible/PVC flexible pipe may use if required in partition wall. All PVC pipes should be with ISI mark. No joints will be allowed inside pipe, light, fan & plug point complete with modular type switch plate & MS box rate Including the main circuit line 2x2.5mmsq+1x1.5mmsq earth PVC insulated Cu. Wire from DB to switch board ,maintaining the color code. Circuit line for lighting switch board & 6Amps plug board are to be drawn from lighting DB to Lighting board & plug point board (independent ), 6/16 Amps plug point line are to be draw from power DB as per DB schedule /SLD a) 1 light by 1 switch (ATM 1 No),UPS Pt 1 in ATM Nos. 4 g) Same as above 5A Point in the switchboard itself. ( ATM 1 No) No 1.00 1.2 Supply and installation of modular type 2 nos 6A & multi pin sockets with 2 nos 6 Amp one way switch housed in MS box to be fixed in partitions or concealed in wall. The box shall be painted with 2 coats of enamel paint over a coat of red oxide primer including wiring for Raw power socket outlet using 2 R runs of 2.50 Sq mm and single run of 1.5 sq mm PVC insulated multi stranded single core copper conductor FRLS wire in 20mm PVC conduit to be laid in floor, partitions, etc. complete with all accessories (looping 2 sets of 2x6A socket outlet in one circuit- from DB) (Raw power). ( ATM 1No) No 1.00 1.3 ACs electrification :- (a) Supply and fixing 20A 3-pin modular socket with 20A one way switch with indicator (near AC indoor unit) housed in manufacturers MS powder coated box to be concealed in wall including Wiring using 2R 2.5 sq mm & single run of 2.5 sq mm PVC insulated multi stranded single core copper conductor FRLS wire in 25mm PVC conduit to be laid in floor, partitions, etc complete with all accessories. (for split AC units) - (from Stabilizer to IDU) Supply. Stabilizer to be installed in the panel room. Nos 2.00 (b) Supply and fixing 20A - 3 pin metal clad socket with plug controlled by a 20A SP MCB (for Ac wall mounted stabilizers) housed in manufacturers MS powder coated box to be concealed in wall including Wiring using 2R 2.5 sq mm & single run of 2.5 sq mm PVC insulated multi stranded single core copper conductor FRLS wire in 25mm PVC conduit to be laid in floor, partitions, etc complete with all accessories. (for split AC units) from AC DB to Stabilizer Nos 2.00 4 DISTRIBUTION BOARDS. Make standard/Legrand/ABB for ATM 4.1 Main DB :S/I of 4 way TPN DB approved brand legrand /Standard/ABB with 63 Amp 4p Isolator 63A FOUR POLE Isolator as main (incomer) 32 A 3 POLE MCB 2 NOS (for UPS-1 & Power & Lighting -1Nos) 10 Amps SP MCB 1 NO FOR LIGHT AND 10A SP MCB 2NOS FOR POWER. 2 No. 20 AMP MCB SP FOR SPLIT AC and 1 No 10 Amp spare Or as per SLD Including Neutral Bar. 01 Set Set 1 4.2 UPS DB : 8 WAY SPN DB FOR UPS , 32AMP DP 2 Nos ( 1 No for Incoming ) 10A SP MCB 1 NO FOR UPS LIGHT, 16A SP MCB 2NOS FOR ATM , 1No16A MCB FOR CCTV power point and 2 Nos Spare or as per SLD Set 1 4.3 Supply, installation, testing and commissioning of 32Amp rated 3 phase to single phase auto phase shifter for ATM UPS (SLHD of Swift make) Nos 0 4.4 Supply & Laying of 4 runs of 4.0 Sq mm and 2 run of 2.5 sq mm, PVC insulated, single core, multi-stranded copper conductor cable in suitable rigid PVC conduit from DB TO AUTO PHASE SHIFTER Mts 0 4.5 Supply & Laying of 2 runs of 4.0 Sq mm and 1 run of 2.5 sq mm, PVC insulated, single core, multi-stranded copper conductor cable in suitable rigid / flexible metal conduit from UPS output / Input control to UPS DB mtr 6 5 as stated item No,:1,1 but UPS lighting, 6/16 Amps plug point line are to be draw from power DB as per DB schedule /SLD a) 1 light by 1 switch (ATM 1N) Nos. 0 b) Wiring (2 x 2.5 mm sq + 1 x 1.5 mm sq from power DBs) for independent 2X6A multi pin socket along with 6A modular type switches housed in painted MS box. For ATM CCTV UPS No 2.00 6 Supply and installation modular type 16A, 5-16 pin sockets with 16A one way switch housed in MS box to be fixed in partitions or concealed in wall. The box shall be painted with 2 coats of enamel paint over a coat of red oxide primer , the rate shall include wiring fusing 2R 4.0 sq mm & single run of 2.5 sq mm PVC insulated multi stranded single core copper conductor FRLS wire in 25mm PVC conduit to be laid in floor, partitions, etc complete with all accessories.(UPS wiring for ATM) one circuit for one 16 amps pin socket .The rate inclusive of machine cutting the tiles from ATM power input to the ATM and laying of 25mm UPVC sleevs in order to run th wire with concealed manner. No power point shall be visible from ATM room inside.(From ATM UPS) Nos. 2 7 Earthing 7.1 Supply, Installation, Testing and Commissioning of Maintenance Free Earthing system made up of copper bonded rod of 10 feet length,23 mm dia. (Minimum copper bonding shall be 0.25mm) along with Rod-to Conductor connectors, Earth enhancement material, Pit Cover and other accessories as required and as per specification and other applicable codes (include chamber for earthing, Earthing certificate to be submitted along with the bil 7.2 1 run of 7 /20 PVC insulated wire along with PVC conduits for earthing. Mts 10 8 ELECTRICAL FITTINGS (S/I/T/C) 8.1 Supply and Installation Recess mounted 2’-0X2-0” watt, 38 W LED FULL GLOW Philips MAKE. Light should be fixed through SS threaded bolt tighted the upper end on ceiling using anchor bolt and lower end on Light fitting with nut and bolt (RC380B G2 LED35S-6500/4000 PSU OD WH) PHILIPS/WIPRO MAKE Nos. 2 8.2 Supply, Installation, testing and commissioning of single colored , 8 meter LED light strip of 5W per meter complete with necessary drivers, all accessories and etc for cove lighting in column paneliling (Bajaj BCFL 300 25W/ Wipro LS 06 005 120/ Philips/Crompton) including connection & mounting arrangement as required w.r.t site conditions.(Fitting and drivers shall be of IP20 protection class) Nos. 4 8.3 SQUARE SHAPE DOWNLIGHTER - INTEGRA 15W, 3000K, LHEBGTP5Z1W015, PHILIPS Razor/WIPRO MAKE Nos. 7 8.4 150 mm dia Heavy Duty Exhaust fan 230 volt A.C. (Havells / Crompton make).(UPS & Toilet ) Nos. 1 8.5 BULB HOLDER - LED. Nos 1 TOTAL FOR ATM ELECTRICAL WORK (D) E SCHEDULE - E (LAN & TELEPHONE WORK ) S.NO. DESCRIPTION UNIT QTY. RATE AMOUNT 1.0 DATA SYSTEM - CONDUITING & CABLING 1.1 1.2 Wiring for computer networking from I/O hub to computer workstation with UTP Cat-6 computer cable including providing ferrules at both ends and termination at both ends including providing & fixing frame for with shutter, RJ 45 outlet, faceplate and mounting box complete of modular type, This work includes providing PVC conduits (1/2, 3/4 size or as required0 in chases from the I/O hub to the point. The cost includes testing, commissioning etc complete. Note: Do not run more than 3 wires in single pipe & should be concealed. (ATM each 2Nos ) Nos. 2 1.3 Supply of Cat - 6 D-Link patch cord 7 0 (ATM 1No) Nos. 1 1.4 Supply of Cat - 6 D-Link patch cord 3 0(ATM 2No) Nos. 1 TOTAL FOR ATM LAN & TELEPHONE (E) GRAND TOTAL ELECTRICAL & DATA CABLING WORK AT BRANCH & ATM (B+C+D+E)

Key Value

Document Fees
Refer document
EMD
INR 5500.0 /-
Tender Value
INR 5.48 Lakhs /-
Disclaimer :