}

Tender For Electrical, Data Cabling & Air Conditioning Works In New Premises Of Indian Bank Lbc Mahoba, District - Mahoba, mahoba-Uttar Pradesh

Indian Bank-IB has published Tender For Electrical, Data Cabling & Air Conditioning Works In New Premises Of Indian Bank Lbc Mahoba, District - Mahoba. Submission Date for this Tender is 07-08-2023. Electrical Maintenance Tenders in mahoba Uttar Pradesh. Bidders can get complete Tender details and download the document.




Tender Notice

38804134
Tender For Electrical, Data Cabling & Air Conditioning Works In New Premises Of Indian Bank Lbc Mahoba, District - Mahoba
Open Tender
Indian
Uttar Pradesh
mahoba
07-08-2023

Tender Details

Tender For Electrical, Data Cabling & Air Conditioning Works In New Premises Of Indian Bank Lbc Mahoba, District - Mahoba 1 ELECTRICAL WIRING & EARTHING 1.1 Supply, laying, connection & testing of light, fan point, wiring by 2x1.5mmsq(2x3/.029) +1x1mmsq PVC insulated, multi-strand single core copper conductor FRLS wire maintaining the color code as per direction in PVC conduit of 20mm with ISI mark 1.5mm thickness to conceal in wall partition mending good the damage, complete with PVC circular box, bend to be done as per drawing including 3 point ceiling rows wherever required GI saddle to be used for fixing, metal flexible/PVC flexible pipe may use if required in partition wall. All PVC pipes should be with ISI mark. No joints will be allowed inside pipe, light, fan & plug point complete with modular type switch plate & MS box rate Including the main circuit line 2x2.5mmsq+1x1.5mmsq earth PVC insulated Cu. Wire from DB to switch board ,maintaining the color code. Circuit line for lighting switch board & 6Amps plug board are to be drawn from lighting DB to Lighting board & plug point board (independent ), 6/16 Amps plug point line are to be draw from power DB as per DB schedule /SLD a) 1 light by 1 switch (ATM 1 No),UPS Pt 3 In branch Nos. 12 b) 2 light by 1 switch Nos. 12 c) 3 light by 1 switch Nos. 0 e) Ceiling fan point with step type electronic regulator No 1 f) Same as above, but for exhaust fan excluding regulator. No 3 g) Same as above 5A Point in the switchboard itself. (for branch 4 No & ATM 1 No) No 5 h) same as above Wiring for call-bell point including buzzer No 1 i) Wiring (2x2.5mmsq+1x1.5mmsq from power DBs) for independent 6A multi pin socket at walls along with 6A modular type switches board housed in painted MS box (up to 3 independent plug points can be taken in one circuit). For wall Fan No 4 1.2 Supply and installation of modular type 2 nos 6A & multi pin sockets with 2 nos 6 Amp one way switch housed in MS box to be fixed in partitions or concealed in wall. The box shall be painted with 2 coats of enamel paint over a coat of red oxide primer including wiring for Raw power socket outlet using 2 R runs of 2.50 Sq mm and single run of 1.5 sq mm PVC insulated multi stranded single core copper conductor FRLS wire in 20mm PVC conduit to be laid in floor, partitions, etc. complete with all accessories (looping 2 sets of 2x6A socket outlet in one circuit- from DB) (Raw power) for counter ( Each counter 1 Nos +BM :2 Nos, ATM 1No:,Pantry 1No.:) No 3 1.3 Supply and installation modular type 16A, 5-pin socket with 16A one way switch housed in MS box to be fixed in partitions or concealed in wall. The box shall be painted with 2 coats of enamel paint over a coat of red oxide primer, the rate shall include wiring fusing 2R 4.0 sq mm & single run of 2.5 sq mm PVC insulated multi stranded single core copper conductor Nos. 5 FRLS wire in 25mm PVC conduit to be laid in floor, partitions, etc complete with all accessories (for line printer : or optional).(up to 2 independent plug points can be taken in one circuit) C.C :1No. BM.;1 No.: Alternative counter 2No + Banking Hall 1 No+ Pantry 1No ,ATM :1No) 1.5 ACs electrification :- (a) Supply and fixing 25 Amps 3-pin modular socket with 25 Amp one way switch with indicator (near AC indoor unit) housed in manufacturers MS powder coated box to be concealed in wall including Wiring using 2R4.0 sq mm & single run of 2.5 sq mm PVC insulated multi stranded single core copper conductor FRLS wire in 25mm PVC conduit to be laid in floor, partitions, etc complete with all accessories. (for split AC units) -(from Stabilizer to IDU)Supply. (2 Nos for ATM), Stabilizer to be installed in the panel room. Nos 2 (b) Supply and fixing 25 Amp - 3 pin metal clad socket with plug controlled by a 25 Amp SP MCB (for Ac wall mounted stabilizers) housed in manufacturers MS powder coated box to be concealed in wall including Wiring using 2R 4.0 sq mm & single run of 2.5 sq mm PVC insulated multi stranded single core copper conductor FRLS wire in 25mm PVC conduit to be laid in floor, partitions, etc complete with all accessories. (for split AC units) from AC DB to Stabilizer (2 Nos for ATM) Nos 2 2 LAYING OF CABLE : 2.1 Supply, laying fixing main power with 50mm sq 3.5 core PVC insulated PVC sheated Alu. Conductor, 1100 v. grade armored cable complete with 02 nos 8 SWG bear GI wire as running earth .( Meter panel to Main Panel & Dgset to Main Panel ) Mts. 20 2.2 End termination of 50mmsq 3.5 Core armored cable, complete with brass cable gland, Alu. Lug, PVC tape. Nos 5 2.3 - Do - 3.5 x 16 sq mm with 02 nos 8 SWG bear GI wire as running earth. for Light D.B Mts 30 2.4 - Do - 3.5 x 25 sq mm th with 02 nos 8 SWG bear GI wire as running earth. for POWER & A.C D.B , UPS & ATM Mts 20 2.5 - Do - termination of 25 & 16 Sq mm 3.5 Core Nos 8 3 Outdoor type glow sign board wiring :- 3.1 Supply, laying of main line with 2x2.5 +1x1.5 mm sq through MS conduit from main panel to glow sign board. Mts 20 3.2 Supply installation of 16 amps DP MCB at main entrance Glow sign board & With Electronic timer as required. Set 1 4 EARTHING STATION : (i) Earthing installation as per I.E. rule conforming Set 2 Supply, Installation, Testing and Commissioning of Maintenance Free Earthing system made up of copper bonded rod of 10 feet length, 23 mm dia. (Minimum copper bonding shall be 0.25mm) along with Rod-to Conductor connectors, Earth enhancement material, Pit Cover and other accessories as required and as per specification and other applicable codes (include chamber for earthing, Earthing certificate to be submitted along with the bill). (ii) Supply laying 2x8SWG copper bear wire from earth spike to main panel. (Electrolyte wire) Mts 20 5 MAIN ELECTRICAL DISTRIBUTION 5.1 S/F of 3 nos. 100Amps Kit kat set link type with heavy duty Set 1 neutral link and making its connection from electronic meter c/w wooden board etc. 5.2 Main Panel (wall Mounted Type) Supply & erection of 6way Electric panel made of 16 gauge M.S sheet with double coated painting consisting 3No (4x40)mm copper strips of suitable length for 200 Amp current rating with supply & erection of followings 1) 63Amp TPN switch 1No make HPl/ Havells/ standard with HRC fuses ll) 63 Amp D.P change over switch 1No lll) 63A Rotary switch -1No lV)10 Amp SP MCB-6No v)Three phase indicator NOTE- Cost of connection of 3 Phase energy meter is including in the job & All internal wiring in D.B Should be 10Sq mm wire. Set 1 5.3 POWER DB & AC DB. Make standard/Legrand/ABB, Double door 6 way TPN MCB DB with TP MCB as incoming 63 TP&N MCB as main 16Amps SP MCB - 8 Nos (Ac: 3 Nos + 2X6amp: 4Nos and 1Nos spare ) +32AMPS SP X10 NOS. (Ac 3 Nos+15 Amp: 6 Nos, 1No Spare) Including Neutral Bar. 01 Set Set 1 5.4 LIGHTING DB Make standard/Legrand/ABB 6 way TPN MCB DB with TP MCB as incoming 63A TP&N MCB as main 32 AMPS DB MCB 1No: For Strong room ) 16 Amps SP MCB - 03 Nos.+ (BM +Toilet) each 1No + 1No spare 12 Amps SP MCB - 12 Nos. (Hall - 4Nos + Store room 1 No + External Lighting 1No.:+ Ups 1No + wall Fan 3 Nos.2 No spare) Including Neutral Bar. 01 Set Set 1 6 UPS SYSTEM (Branch) 6.1 UPS Main DB Supply, erection, testing and commissioning of three phase 4 WAY, TPN MCB DB double door type with C Curve MCBs, IP 42 powder coated for UPS with 63A 4P MCBs – 1No as INCOMER 32A TP MCBs – 3 Nos. as OUTGOING (UPS :2Nos and 1 set ,: Spare Including all interconnections & accessories etc Make standard/Legrand/ABB Nos 1 6.2 Supply & Fixing of 32A DP MCB in 2way SPN Db IP 20 metallic directly on wall Raw power Incoming & Outgoing supply for UPS (Branch :2 Nos & ATM 1No.) Nos 2 6.3 UPS DB-1 & 2 combined 12 Way SPN MCB DB with C curve MCBs. Incoming: 2 No. 40A DP MCB Outgoing: 8 Nos 6/10A (BM: 1+1 Nos with lighting : Server & Data Rack (1+1) Nos: C.C 2Nos with lighting :counter :2 Nos) SPO MCBs Make standard/Legrand/ABB. Respective UPS lighting to be connected.(BM, C.C, Banking hall 2Nos) or as per SLD Nos 1 6.4 Supply and installation of modular type 3 nos 6A multi pin sockets with 2 nos 6A one way switch with indicator housed in MS box to be fixed in partitions or concealed in wall. The box shall be painted with 2 coats of enamel paint over a coat of red oxide primer including making connections complete the rate inclusive of Supplying and running of 3 runs of 2.5 sq.mm UPS DBs to individual power station through. (looping 2 sets of 3X6 A socket outlet in one circuit / or as per SLD the following Nos 4.00 size of 660 volts grade, Finolex brand PVC insulated wire (For UPS point only).(For B.M, C.C, Server each 2Nos.) +5 Nos for Counter + Rack 1Nos) 6.5 Supply & Laying of 4 runs of 6.0 Sq mm and 2 runs of 2.5 sq mm, PVC insulated, single core, multi-stranded copper conductor cable in suitable rigid / flexible metal conduit from Main UPS DB to auto phase shifter. mtr 10 6.6 Supply, installation, testing and commissioning of 40A rated 3 phase to single phase auto phase shifter for 3.0 KVA UPS (SLHD of Swift make) Nos 2.00 6.7 Supply & Laying of 2 runs of 6.0 Sq mm and 1 run of 2.5 sq mm, PVC insulated, single core, multi-stranded copper conductor cable in suitable rigid PVC conduit from auto-match phase shifter to UPS unit mtr 10 6.8 Supply and Installation of Moduler type 2 X 20A plugs & socket housed in for UPS output control (Branch 2 Nos & ATM 1No.) Nos 2.00 6.9 Supply & Laying of 2 runs of 4.0 Sq mm and 1 run of 2.5 sq mm, PVC insulated, single core, multi-stranded copper conductor cable in suitable rigid / flexible metal conduit from 3 KVA UPS to UPS DB mtr 10 8 ELECTRICAL FITTINGS (S/I/T/C) 8.1 Supply and Installation Recess mounted 2-0X2-0 watt, 38 W LED FULL GLOW Philips MAKE . Light should be fixed through SS threaded bolt tighted the upper end on ceiling using anchor bolt and lower end on Light fitting with nut and bolt (RC380B G2 LED35S-6500/4000 PSU OD WH)PHILIPS/WIPRO MAKE (ATM 2 No) Nos. 6 8.3 SQUARE SHAPE DOWNLIGHTER - INTEGRA 15W, 3000K, LHEBGTP5Z1W015, PHILIPS Razor/WIPRO MAKE (ATM 2NOS) Nos. 23 8.4 TUBELIGHT - LED TUBELIGHT 36 W, PHILIPS/WIPRO MAKE. ATM 1 No Nos 4 8.5 HANGING LIGHT - LHECDOL5PW1W040 (40WATTS), PHILIPS/WIPRO MAKE NOS. 2 8.6 150 mm dia Heavy Duty Exhaust fan 230 volt A.C .(Havells / Crompton make).(UPS & Toilet ) Nos 3 8.7 M.S body frame Wall mounting fan 450 mm dia 230 volt A.C. PHILIPS/WIPRO MAKE Nos. 4 8.8 Supply of Ceiling fan with 1200mm sweep, double ball bearing motor, capacitor, three MS blades die cast Al housing in stove enameled white with, suspension rod including all accessories of approved make. (5 star rated) (ORIENT/KHAITAN). (UPS, Strong room & Store room) Nos. 1 TOTAL FOR ELECTRICAL WORK (B) C SCHEDULE - C (LAN & TELEPHONE WORK ) S.NO. DESCRIPTION UNIT QTY. RATE AMOUNT 1.0 TELEPHONE SYSTEM 1.1 Wiring for telephone points with 2 pair 4/5 pair .51mm dia ATC (annealed tinned Cu wire) with PVC insulated PVC sheathed telephone cable from tag block to the point including providing ferrules at both ends and termination at both ends including providing & fixing RJ 11 outlet, faceplate and mounting box complete of modular type 9 where 2 such points are shown, 2 such wires shall be provided) This work includes providing PVC conduits in chases from the raceway to the point. (1 each for branch manager, C.C. P. officer & Clerck). separate IO box to be provided for Telephone Nos. 2 1.2 Supplying, laying effecting terminations, testing and commissioning of 0.51mm dia Cu. Conductor, twisted, color coded with polythene capor barrier, telephone cables in the existing tray or in conduit including providing & fixing conduit pipe or cable tray as required from building tag block to the floor as required. a 0.5mm, 5 pair armored telephone cable from telephone connection in the premises to the crone box. rmt 10 b Supplying & fixing 20 pair krone tag block with enclosure. Nos. 1 2.0 DATA SYSTEM - CONDUITING & CABLING 2.2 Wiring for computer networking from I/O hub to computer workstation with UTP Cat-6 computer cable including providing ferrules at both ends and termination at both ends including providing & fixing frame for with shutter, RJ 45 outlet, faceplate and mounting box complete of modular type, This work includes providing PVC conduits (1/2, 3/4 size or as required0 in chases from the I/O hub to the point. The cost includes testing, commissioning etc complete. Note: Do not run more than 3 wires in single pipe & should be concealed. ( Server, BM, CC & ATM each 2Nos and counter 5Nos) Nos. 5 2.3 Supply of Cat - 6 D-Link patch cord 7 0 (ATM 1No) Nos. 5 2.4 Supply of Cat - 6 D-Link patch cord 3 0(ATM 2No) Nos. 5 2.5 Supply & fixing 24 Port Jack Panel Make:-D-Link Nos. 1 2.6 19 Rack 9U with Glass Door , Locking system Make: APW Nos. 1 2.7 24PORT 10/100Mbps Switch Nos. 1 TOTAL FOR LAN & TELEPHONE (C) AIR CONDITIONING WORKS 1 All items of work under this Contract shall be executed strictly to fulfill the requirements laid down in the specifications. Type of equipment, material specification, methods of installation and testing and type of control shall be in accordance with the specifications, approved shop drawings and the relevant Indian Standards, however capacity of each component and their quantities shall be such as to fulfill the above mentioned requirement. The basis of the design to be submitted by contractor for approval by Bank. 2 The rate for each item of work included in the Schedule of Quantities shall, unless expressly stated otherwise, include cost of: a) All materials, fixing materials, accessories, appliances tools, plants, equipment, transport, labour and incidentals required in preparation for and in the full and entire execution, testing, balancing, commissioning and completion of work called for in the item and as per Specifications and Drawings. b) Wastage on materials and labor. c) Loading, transporting, unloading, handling/double handling, hoisting to all levels, setting, fitting and fixing in position, protecting, disposal of debris and all other labor necessary in and for the full and entire execution and for the job in accordance with the contract documents, good practice and recognize principles. d) Liabilities, obligations and risks arising out of Conditions of Contract. e) All requirements of Specifications, whether such requirements are mentioned in the item or not. The Specifications where available, are to be read as complimentary to and part of the Schedule of Quantities and any work called for in one shall be taken as required for all. f) In the event of conflict between Schedule of Quantities and other documents including the Specifications and approved basis of design, the most stringent shall apply. The interpretation of the Bank shall be final and binding. 3 All equipment, quantities and technical data indicated in this Schedule are for the Contractor’s guidance only. This schedule must be read in conjunction with other documents and site conditions. The Contractor shall be paid for the actual quantity of work executed by him in accordance with the approved Shop Drawings & Basis of Design at the contract rates. 4 This Schedule shall be fully priced and the extensions and totals duly checked. The rates for all items shall be filled in INR including NIL items. 5 No alteration whatsoever is to be made to the text or quantities of this Schedule unless such alteration is authorized in writing by Services Consultant. Any such alterations, notes or additions shall, unless authorized in writing, be disregarded when bid documents are considered. 6 The Contractor shall procure and bring Materials/Equipment to the site only on the basis of site conditions and not on the basis of Schedule of Quantities which are approximate only. This also applies to the Contractor’s requisition for Owner supplied materials. 7 The unit rate for all local equipment or materials in Indian Rupees shall include cost of equipment and materials including all taxes and duties and also including forwarding, freight, insurance and transport into Contractor’s store at site, storage, installation, testing, balancing, commissioning and other works required. 8 The Contractor / Vendor are free to make site visit to ascertain the working conditions and other relevant site feasibility/feature 9 One year (12 months) on site Comprehensive Warranty (DLP) for complete work from the date Of acceptance by Bank. AIR CONDITIONING WORK) 1 Supplying, installation, testing and commissioning of 3-Star rated as per 2024 version Hi-wall split air conditioner of following capacity with On Off Timer along with wireless remote controller including providing and laying the standard length of 5 m copper, electrical and 25mm dia heavy duty PVC drain piping with all necessary fittings duly insulated with 9mm thick nitrile rubber pipe insulation including Initial refrigerant charge suitable for 5 Mtrs distance between IDU and ODU along with drilling the holes and packing and making good the damaged surfaces good comprising and 5 mtr Condenstate drain pipe as specified spec of the following:- i) Indoor unit consisting of evaporator coil, blower fan with motor, filters, insulated drain pan control panel with cabling between control panels and units etc ii) Outdoor unit consisting of hermatically sealed Rotary Compressor to operate on 230 V, Single Phase, 50 Hz AC Supply, Anti Corrosive Coated Condensor Coil with fan and motor, interconnecting refrigeration piping, starters/ controls/ cutouts/ relays etc., mounted inside a powder coated sheet metal cabinet duly treated for corrosion protection the rate included interconnecting cable from indoor unit to outdoor unit (APPROVED BRAND :DAIKIN, BLUE STAR, CARRIER, HITACHI, O GENERAL) B 3-Star rated Hi-wall split air conditioner of 1.5 TR capacity *blue Star/Hitachi/Carrier Each 2 MAKE MODEL WARRANTY C 3-Star rated Hi-wall split air conditioner of 1.0 TR capacity Each 0 2 Charges for providing additional copper pipes (one circuit) for the above split units with necessary insulation and with adequate PVC insulated copper wire from indoor to outdoor units concealed and taken through beyond the standard 5 mtr length. Rmt 20 3 Charges for providing additional 25 mm dia heavy duty PVC drain piping with all necessary fittings duly insulated with 9mm thick nitrile rubber pipe insulation drain pipe concealed / surface mounted and taken through wall / partition beyond the standard 5m length for the above split units. Rmt 20 4 Supply, installation, testing and commissioning of wall mounting 4KVA stabilizers for 1.5Tr & 1.0Tr Hi-Wall Split Air Conditioning units with input voltage range of 170-270 Volts and output 220 +/- 10% as required. Each 2 6 Providing and fixing standard powder coated support brackets & including grille gauge with locking arrangement for the above split / cassette units including fasteners and other accessories as required. a For split air conditioner Each 2 7 Supplying and fixing 0-24 hrs electronic timer with 2nos 25A SP MCBs, 2 nos 25A TP contactors completely wired housed in a suitable powder coated enclosure with hinged door and mounted on wall with all interconnections. (for ac units in System Room) No 2 8 Supplying, installation, testing and commissioning of CASSETTE type split air conditioner of 2 TR capacity ,with 3star rated as per 2024 with On Off Timer along with wireless remote controller including Initial refrigerant charge suitable Each 0 for 5 Mtrs distance between IDU and ODU along with drilling the holes and packing and making good the damaged surfaces and min 5 mtr Condenstate drain pipe as specified spec (2nos in Banking Hall) comprising of the following:- Min 3 star rated as per 2024 i) Indoor unit consisting of evaporator coil, BLDC Fan Motor, filters, insulated drain pan, drain pump, One motor per vane in Indoor unit to control each of the four vanes independently, etc ii) Outdoor unit consisting of hermatically sealed Rotary Compressor to operate on 230 V, Single Phase, 50 Hz AC Supply, Anti Corrosive Coated Condensor Coil with fan and motor, interconnecting refrigeration piping, starters/ controls/ cutouts/ relays, etc., mounted inside a powder coated sheet metal cabinet duly treated for corrosion protection the rate included interconnecting cable from indoor unit to outdoor unit (APPROVED BRAND :DAIKIN, BLUE STAR, CARRIER, HITTACHI, O GENERAL) 9 Supply and installation of Liquid and Gas Hot Line Copper tubing, thermal insulation of Copper Pipes, Condenser fan Cabling, earthing, clamping, control cabling if any, between IDU & ODU of CCDS units.(beyond 5 meter) Rmt 0 10 Providing and laying 25 mm dia heavy duty hard drain piping for all Cassette type split air-conditioners with all necessary fittings, accessories and supports including insulating the drain pipe properly with closed cell elastometric Nitrile rubber / EPS section.(beyond 5 meter) Rmt 0 TOTAL FOR AIR CONDITIONING (D) GRAND TOTAL-B+C+D

Key Value

Document Fees
Refer document
EMD
INR 3500.0 /-
Tender Value
INR 3.58 Lakhs /-
Disclaimer :
We takes all possible care for accurate & authentic tender information, however Users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender.
Tell us about your Product / Services,
We will Find Tenders for you

Copyright © 2024 · All Rights Reserved. Terms of Usage | Privacy Policy

For Tender Information Services Visit : TenderDetail