Tender For Installation Of 3 Semi High Mast Light At Park (Opposite B-13 Lajpat Nagar 2 - 01 No. Shm, Park In Front Of L-26 Lajpat Nagar 2- 01 No. Shm, Park In 6 Block Nehru Nagar - 01 No. Shm) In Central Zone.-Electrical Work, Delhi-Delhi

Municipal Corporation-MC has published Tender For Installation Of 3 Semi High Mast Light At Park (Opposite B-13 Lajpat Nagar 2 - 01 No. Shm, Park In Front Of L-26 Lajpat Nagar 2- 01 No. Shm, Park In 6 Block Nehru Nagar - 01 No. Shm) In Central Zone.-Electrical Work. Submission Date for this Tender is 31-07-2023. Electrical Maintenance Tenders in Delhi Delhi. Bidders can get complete Tender details and download the document.




Tender Notice

38801674
Tender For Installation Of 3 Semi High Mast Light At Park (Opposite B-13 Lajpat Nagar 2 - 01 No. Shm, Park In Front Of L-26 Lajpat Nagar 2- 01 No. Shm, Park In 6 Block Nehru Nagar - 01 No. Shm) In Central Zone.-Electrical Work
Open Tender
Indian
Delhi
Delhi
31-07-2023

Tender Details

Installation Of 3 Semi High Mast Light At Park ( Opposite B-13 Lajpat Nagar 2 - 01 No. Shm, Park In Front Of L-26 Lajpat Nagar 2- 01 No. Shm, Park In 6 Block Nehru Nagar - 01 No. Shm ) In Central Zone.-Electrical Work. 1 OD5263/2023-2024:Earthing with G.I. earth pipe 4.5 metre long, 40 mm dia including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe etc. with charcoal/ coke and salt as required. 2 OD5264/2023-2024:Providing and laying earth connection from earth electrode with 6 SWG dia G.I. Wire in 15 mm dia G.I. pipe from earth electrode including connection with G.I. thimble excavation and re-filling as required. 3 OD5265/2023-2024:Laying of one number PVC insulated and PVC sheathed/ XLPE power cable of 1.1 KV grade of following size in the existingRCC/HUME/METAL pipe as required. Up to 35 sqmm 4 OD5267/2023-2024:Laying and fixing of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size in the existing masonry open duct as required. Up to 35 sqmm 5 OD5268/2023-2024:Supplying and fixing of light class GI pipe of 50 mm dia (nominal) 3 meters length along the pole for protection of under ground cable as required. 6 OD5269/2023-2024:S/L of following size DWCHDPEPipe ISI marked along with all accessories like socket ,bend ,couplers etc.conforming to IS 14930 ,partII complete with fittingand cutting ,jointing etc .direct in ground (75 cm below ground level )including excavationand refilling the trench but excluding sand cushioning and protective covering etc, complete as required (a)63mm dia (OD-63mm ID -51mm nominal ). 7 16.61:Providing Retro - reflective regulatory sign board of size 900 mm diameter made out of 2 mm thick aluminiumsheet, face to be fully covered with high intensity encapsulated lens type retro reflective sheeting as approved by Engineer-in-Charge.Letter, symbols, borders etc. will be as per IRC. 67 with required colour scheme on the boards and with the high intensity grade A.The aluminium sheet to be riveted to M.S. frame of M.S. angle 50x50x4 mm , 4 m long welded to the frame with adequate anti-theft arrangement. Sheet work to be painted with two or more coats of synthetic enamel paint over an under coat ( primer ) and back side of aluminium sheet to be painted with two or more coats of epoxy paint including appropriate priming coat complete in all respects as per direction of Engineer- in-charge . 8 122.2.24:Providing and laying of HDPE PIPE OF 40mm outer dia with PN 4 rating by hand Moling/Mannual method Confirming to IS 4984 592 9 122.1.3:Supply of XLPE insulated PVC sheathed Al. Conductor Armoured Cable 1.1KV grade conforming to IS-7098 of following size:-2C*10 sqmm 10 122.2.19:Fabrication,Supplying,Installation,testing,Commissioning of 12 mtr high mast System with its accessories ,Mast shaft shall be in one section , hot dip galvanized 4mm thick(Single dip ) inside & out sides &suitable for wind velocity as per IS 875 part3 .There shall be in longitudinal seam weld per section and No circumferential weld. It should also included accessories For High Mast head frame ,2 point suspension system, 5*2.5 sqmm Cu conductor with steel wire rope 5mm dia. (7/19construction) single drum winch ,galvanized lantern carriage arrangement suitable for 4/6 Nos. Flood Light luminariessymmetrically And its control gears boxes and lighting finial ,the mast shall have integral type manual tool mounted at the base compartment of its raising and lowering operation with foundation bolts and Anchor plate and control panelhousing suitable RCC (1:2:4) shallowfoundation of size 1m(L) x 1m wide and 2m deep i/c excavation of earth, providing cutting, bending and placing in position, reinforcement of cold twisted bars of 12 mm dia -2100mm long (approx.) - 16 nos.and reinforcement of cold twisted bar of 8 mm dia - 3700 mm (approx.) - 13 nos. (with 150 mm spacing) as required with positioning of foundation bolts and providing DWC HDPE pipe for cable entry & exit as required for the high mast considering The safe soil bearing capacity at site as 10T/sqm at 2mts. Depth with all material i/c 4Nos S.P MCB,63Amp.DPIsolator etc as reqd. Logo/Name of manufacturer shall be embossed on the pole. Galvanization as per relevant IS. 11 OD5270/2023-2024:Supply and fabrication of pole protection system made up 8 SWG steel wire mesh of size 25mm x75mm rectangular with 50mm x50mm x6mm MS angle iron for supporting the mesh i/c MV Danger Plate and grounding the protection system in suitable quality of CC etc.

Key Value

Document Fees
INR 590 /-
EMD
INR 12686.0 /-
Tender Value
INR 6.30 Lakhs /-

BOQ Items

Name of Work:Installation of 3 Semi High Mast Light at park (opposite B-13 Lajpat Nagar 2 - 01 no. SHM, Park in front of L-26 Lajpat Nagar 2- 01 no. SHM, Park in 6 block Nehru Nagar - 01 no. SHM) in Central Zone.-Electrical Work
Sl. No. Item Description
1OD5263/2023-2024:Earthing with G.I. earth pipe 4.5 metre long, 40 mm dia including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe etc. with charcoal/ coke and salt as required.
2OD5264/2023-2024:Providing and laying earth connection from earth electrode with 6 SWG dia G.I. Wire in 15 mm dia G.I. pipe from earth electrode including connection with G.I. thimble excavation and re-filling as required.
3OD5265/2023-2024:Laying of one number PVC insulated and PVC sheathed/ XLPE power cable of 1.1 KV grade of following size in the existingRCC/HUME/METAL pipe as required. Up to 35 sqmm
4OD5267/2023-2024:Laying and fixing of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size in the existing masonry open duct as required. Up to 35 sqmm
5OD5268/2023-2024:Supplying and fixing of light class GI pipe of 50 mm dia (nominal) 3 meters length along the pole for protection of under ground cable as required.
6OD5269/2023-2024:S/L of following size DWCHDPEPipe ISI marked along with all accessories like socket ,bend ,couplers etc.conforming to IS 14930 ,partII complete with fittingand cutting ,jointing etc .direct in ground (75 cm below ground level )including excavationand refilling the trench but excluding sand cushioning and protective covering etc, complete as required (a)63mm dia (OD-63mm ID -51mm nominal ).
716.61:Providing Retro - reflective regulatory sign board of size 900 mm diameter made out of 2 mm thick aluminiumsheet, face to be fully covered with high intensity encapsulated lens type retro reflective sheeting as approved by Engineer-in-Charge.Letter, symbols, borders etc. will be as per IRC. 67 with required colour scheme on the boards and with the high intensity grade A.The aluminium sheet to be riveted to M.S. frame of M.S. angle 50x50x4 mm , 4 m long welded to the frame with adequate anti-theft arrangement. Sheet work to be painted with two or more coats of synthetic enamel paint over an under coat ( primer ) and back side of aluminium sheet to be painted with two or more coats of epoxy paint including appropriate priming coat complete in all respects as per direction of Engineer- in-charge .
8122.2.24:Providing and laying of HDPE PIPE OF 40mm outer dia with PN 4 rating by hand Moling/Mannual method Confirming to IS 4984 592
9122.1.3:Supply of XLPE insulated PVC sheathed Al. Conductor Armoured Cable 1.1KV grade conforming to IS-7098 of following size:-2C*10 sqmm
10122.2.19:Fabrication,Supplying,Installation,testing,Commissioning of 12 mtr high mast System with its accessories ,Mast shaft shall be in one section , hot dip galvanized 4mm thick(Single dip ) inside & out sides &suitable for wind velocity as per IS 875 part3 .There shall be in longitudinal seam weld per section and No circumferential weld. It should also included accessories For High Mast head frame ,2 point suspension system, 5*2.5 sqmm Cu conductor with steel wire rope 5mm dia. (7/19construction) single drum winch ,galvanized lantern carriage arrangement suitable for 4/6 Nos. Flood Light luminariessymmetrically And its control gears boxes and lighting finial ,the mast shall have integral type manual tool mounted at the base compartment of its raising and lowering operation with foundation bolts and Anchor plate and control panelhousing suitable RCC (1:2:4) shallowfoundation of size 1m(L) x 1m wide and 2m deep i/c excavation of earth, providing cutting, bending and placing in position, reinforcement of cold twisted bars of 12 mm dia -2100mm long (approx.) - 16 nos.and reinforcement of cold twisted bar of 8 mm dia - 3700 mm (approx.) - 13 nos. (with 150 mm spacing) as required with positioning of foundation bolts and providing DWC HDPE pipe for cable entry & exit as required for the high mast considering The safe soil bearing capacity at site as 10T/sqm at 2mts. Depth with all material i/c 4Nos S.P MCB,63Amp.DPIsolator etc as reqd. Logo/Name of manufacturer shall be embossed on the pole. Galvanization as per relevant IS.
11OD5270/2023-2024:Supply and fabrication of pole protection system made up 8 SWG steel wire mesh of size 25mm x75mm rectangular with 50mm x50mm x6mm MS angle iron for supporting the mesh i/c MV Danger Plate and grounding the protection system in suitable quality of CC etc.
Disclaimer :