Maintenance Of Gachirampara L.I Scheme Under Gachiramparaadc Village Of Dasda Rd Block Under Water Resource Sub-Divison, Kanchanpur , North Tripura During The Year 2023-2024.Sh:- Remodeling Of Upvc Distribution System Etc..
Tender Overview
Project Description
Maintenance Of Gachirampara L.I Scheme Under Gachiramparaadc Village Of Dasda Rd Block Under Water Resource Sub-Divison, Kanchanpur , North Tripura During The Year 2023-2024.Sh:- Remodeling Of Upvc Distribution System Etc..
BOQ
| Sl. No. | Item Description |
| 1 | Providing, fixing and laying fabricated UPVC end cap conforming to IS : 10124 (Part 4) with solvent cementconforming to IS : 14182 including testing of joints complete as perCPWD specification and direction of the Engineer - in - charge.a) 90 mm dia |
| 2 | b) 110 mm dia |
| 3 | c) 140 mm dia |
| 4 | d) 160 mm dia |
| 5 | Providing, fixing and laying fabricated UPVC straight reducer conforming to IS : 10124 (Part 3) with solvent cementconforming to IS : 14182 including testing of joints complete as per CPWD specification and direction of the Engineer - in - charge.a) 110 x 90 mm dia |
| 6 | b) 140 x 110 mm dia |
| 7 | c) 140 x 90 mm dia |
| 8 | d) 160 x 140 mm dia |
| 9 | Providing & fixingC.I. sluice valve (with CAP)completewith bolts, nuts, rubber indertions etc. ( the tail piece if required will be paid separetely ) as per CPWD specification and direction of the Engineer-in-charge. a) 100 mm dia PN-1.6 |
| 10 | b) 125 mm dia PN-1.6 |
| 11 | c) 150 mm dia PN- 1.6 |
| 12 | d) 200 mm dia PN-1.6 |
| 13 | e) 250 mm dia PN-1.6 |
| 14 | Constructing masonry Chamber 90 x 90 x 100 cm, inside with brick work in cement mortar 1 : 4 ( 1 cement : 4 fine sand ) for sluice valve, with C.I. surface box 100 mm top diameter, 160 mm bottom diameter and 180 mm deep ( inside ) with chained lid and RCC top slab 1 : 2 : 4 mix ( 1 cement : 2 fine sand:4 graded stone aggregate 20 mm nominal size ) necessary excavation foundation concrete 1 : 5 : 10 ( 1 cement : 5 fine sand : 10 graded stone aggregate 40 mm nominal size ) and inside plastering with cement mortar 1 : 3 ( 1 cement : 3 fine sand ) 12 mm thick finished with a floating coat of neat cement complete as per standard design, CPWD specification and direction of the Engineer - in - charge.A. With 1st class bricks. |
| 15 | Providing & fitting fixing MS tail piece with MS flange suitable for pipes complete as per CPWD Specification & direction of Engineer in-charge.a) 100 mm dia PVC Pipe |
| 16 | b) 125 mm dia PVC Pipe |
| 17 | c) 150 mm dia PVC Pipe |
| 18 | d) 200 mm dia PVC Pipe |
| 19 | e) 250 mm dia PVC Pipe |
| 20 | Providing and fitting fixing of different dia rigid UPVC unequal Tee (including earth cutting & backfilling all socketted) suitable for pipes as per IS specification of Working pressure 2.5/4.0 kg/sq.cm confirming to IS: 10124 (Part-V) as per CPWD Specification & direction of Engineer-in-charge.a) 315 x 315 x 250 mm dia |
| 21 | b) 315 x 315 x 200mm dia |
| 22 | c) 315 x 315 x 160 mm dia |
| 23 | d) 250 x 250 x 200mm dia |
| 24 | e) 250 x 250 x 160mm dia |
| 25 | f) 250 x 250 x 140 mm dia |
| 26 | g) 200 x 200 x 160 mm dia |
| 27 | h) 200 x 200 x 140 mm dia |
| 28 | i) 200 x 200 x 110 mm dia |
| 29 | j) 160 x 160 x 140mm dia |
| 30 | k) 160 x 160 x 110 mm dia |
| 31 | l) 160 x 160 x 90 mm dia |
| 32 | m) 140 x 140 x 110 mm dia |
| 33 | n) 140 x 140 x 90mm dia |
| 34 | o) 110 x 110 x 90 mm dia |
| 35 | Providing and fitting fixing of different dia rigid UPVC equal Tee (including earth cutting & backfilling all socketted) suitable for pipes as per IS specification of Working pressure 2.5/4.0 kg/sq.cm confirming to IS: 10124 (Part-V) as per CPWD Specification & direction of Engineer-in-charge.a) 90 x 90 X 90 mm dia |
| 36 | b) 110 x 110 X 110 mm dia |
| 37 | c) 140 x 140 X 140 mm dia |
| 38 | d) 160 x 160 X 160mm dia |
| 39 | Providing and fitting fixing rigid UPVC Reducing socket (one size lower at one end, both end socketted) suitable for pipes of Working pressure 2.5/4.0 kg/sq.cm. as per CPWD Specification & direction of Engineer-in-charge.a) 315x250 mm dia |
| 40 | b) 250x200 mm dia |
| 41 | c) 200x160 mm dia |
| 42 | d) 160x140 mm dia |
| 43 | e) 140x110 mm dia |
| 44 | f) 110x90 mm dia |
| 45 | Providing&fittingfixingrigidUPVCbend (30degree, 45degree, 60 degree,90 degree) for UPVC pipes as per IS specification of Working pressure 2.5/4.0 kg/sq.cm as per CPWD Specification & direction of Engineer-in-charge.a) 160 mm dia |
| 46 | b) 140 mm dia |
| 47 | c) 110 mm dia |
| 48 | d) 90 mm dia |
| 49 | Excavating trenches of required width for pipes, cables, etc.includingexcavationfor socketsand dressingof sidesramming of bottoms , depth minimum 1.25mincluding getting out the excavated soil and then returning the soil as required in layers not exceeding20cmindepthincludingconsolidatingeachdeposited layers by ramming watering etc. and disposal of surplus excavated soil as directed within a lead of 50 m as per CPWD Specification & direction of Engineer-in-charge.A) All kinds of soil.a) Pipe , cables etc. exceeding 75mm diabut not exceeding 160 mm dia . |
| 50 | b) Pipe , cables etc. exceeding 200 mm diabut not exceeding 315 mm dia . |
| 51 | Providing and fitting fixing of G.I hydrant suitable for PVC pipesas per standard specification complete as per direction of Engineer-in- charge (Rate excluding the cost of NTP controlvalve). 80 X 50 mm dia |
| 52 | Providing and fitting fixing of CI(Cast Iron) NTP control valve (40mm) suitable for fitting fixing with GI hydrant point as per CPWD Specification & direction of Engineer-in-charge. |
| 53 | Providing and laying different dia rigid UPVC pipes of Working Pressure 2.5 kg/4.0 kg/ sq.cm. complete with necessary coupler and solvent cement as per CPWD Specification & direction of Engineerin- charge.a) 90 mm dia |
| 54 | b) 110 mm dia |
| 55 | c) 140 mm dia |
| 56 | d) 160 mm dia |
| 57 | e) 200 mm dia |
| 58 | f) 250 mm dia |
| 59 | g) 315 mm dia |
| 60 | Providing and fitting fixing of M.S shore manifold made with 3mm thick MS sheet of size one way 315 mm dia & three way 125 mm dia made with suitable flange(all end) including coating with sheet primer (tailpiece if required will be paid separately) including proper alignment with pipe line & earth cutting ,backfilling complete as per direction of Engineer-in-charge. |
| 61 | Labour charge for laying of G.I pipe conforming IS 1161,3589 & 1239 including fitting fixing complete as per direction of Engineer-in-Charge.a) 125 mm dia |
| 62 | b) 150 mm dia |
| 63 | Supplying & fitting fixing of G.I bend of approved quality.a) 150 mm dia |
| 64 | b) 125 mm dia |
| 65 | Supplying & fitting fixing of 125 mm dia G.I bend of approved quality. |
| 66 | Providing & fitting fixing M.S flange (10mm thick) at site of work of approved quality.a) 150 mm dia |
| 67 | b) 125 mm dia |
| 68 | Providing & fitting fixing Rubber flange washer 6 mm thick at site of work of approved quality.a) 150 mm dia |
| 69 | b) 125 mm dia |
AI Tender Summary
Tender Timeline
Tender Published
Tender notice published.
CompletedBid Submission Deadline
Online submission via eProcurement portal.
CompletedBid Opening Date
Technical bids will be opened and evaluated.
CompletedTender Documents
Download All (ZIP) ↓We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender