Tender For Repair And Maintenance Of E/M Installation And Other Misc Work At Mil Stn Dappar Under Age (I) Dappar
Tender Value
Ref. Documents
Estimated cost
Bid Submission
12 Aug 2023
0 days left
EMD
30000
Bank guarantee accepted
Document Fee
500
Non-refundable
Tender Type
Online
Tender Overview
Organization
Tender ID
Competition Type
NCB
Bidding Type
Tender
Location / State
dappar → Punjab
EMD Exemption
Not Available
Quantity
Not Available
Website
Contact Person
Address
Project Description
Repair And Maintenance Of E / M Installation And Other Misc Work At Mil Stn Dappar Under Age ( I ) Dappar
BOQ
| Sl. No. | Item Description |
| 1 | Disconnecting & Taking out old unserviceable LT cable of size up to 120 sq mm 3.5 core |
| 2 | Supply, laying, jointing, connecting, testing & commissioning UG cable XLPE insulated, screened, PVC bedded, galvanised steel strip armoured electric power cable (heavy duty 1100 volts grade with standard aluminium conductor of cross sectional area 120 sqmm x 3.5 core all as specified and directed by Engr-in-Charge.NOTE - (a). The quoted rate is deemed to be inclusive of arranging respective shutdown, disconnection of cables, commissioning of feeder after the completion of job and inclusive of any minor spares and jobs required for the completion of the job. (c). The cost of excavation, returning, filling, removal and PCC cable covers will be measured and paid under relevant items of this schedule. |
| 3 | Description all as per ser item No 9 here-in-before but size of LT under ground cable 10 sqmm 2core. |
| 4 | Excavation in trenches in soft/loose/hard soil n exc 1.5 m wide and not exc 1.5 m in depth and getting out including forming bottom to required level or slope for laying pipes / laying of cable complete all as specified and as directed by Engineer-in-Charge. |
| 5 | Returning filling in soft / loose soil in trenches including spreading, leveling and well ramming in 25 cm thick layers complete all as specified and as directed by Engineer-in-Charge. |
| 6 | Removal of surplus soil to a distance n exc in 50 m and deposited where directed at a level n exc 1.5 m above the starting point complete all as specified and as directed by Engineer-in-Charge. |
| 7 | Material and labour sand cushioning (dry river sand) to underground cable for cable protection 23 cm thick in two layers (8 cm thick before laying of cables and 15 cm thick after laying the cable and punning down the sand to 18 cm thickness.). Complete all as specified and as directed by Engineer-in-Charge. (Note:- Only punned thickness 18 cm of sand shall be measured for payment purposes). |
| 8 | M&L precast concrete cable cover, class LV, type 1 with peak, size 250mm x 150mm x 40mm. |
| 9 | Material and labour for galvanized iron tubing size 80 mm bore (Light grade) with all necessary fittings laid in trenches under road crossing or fixed on poles / walls / under floors for cable protectioncomplete all as specfied and as directed. Make:- Jindal. Complete all as specified and as directed by Engineer-in-Charge. |
| 10 | M & L for earthingwith galvanised iron earth plate of size 600x600x6mm thick buried directly in ground not less than 2.25m below normal ground level,earth plate packed on all sides with charcoal mixed with salt in alternate layers of 15 cm thickness connected by galvanised iron earth earth strip 32x6mm soldered & riveted toearth plate, galvanised iron earth strip will be provided by using 50mm bore galvanised iron pipe (light grade) earth plate to transformer body and neutralor test point of transformer, including flat iron clamp 25x3mm including bolts, nuts and washers complete including watering galvanised iron pipe 20 mm dia \"Light grade\" 2.5mm long the earthing includes PCC pit including necessary earth works and disposal of surplus soil to a distance not less than 50m, chamber of PCC 1:4:8 type D-2 using 40mm graded stone aggregate, coping shall be of PCC 1:3:6 type C-I using 20mm graded stone aggregate, RCC pit cover 50mm thick in1:2:4 type B-I using 20mm graded stone aggregate, rein forced with 8mm dia @ 15cm c/c complete all as shown on sketch No 3 of SSR-I of 2009 and as specified and as directed by Engr-in-Charge. |
| 11 | M & L for Black/Green over earthing pit and Pit cover with numbering with Stencil size of 12CM art in white on Earthing Pit cover with two coats of 1st quality synthetic enamel paint of Black/ Greenover a coat of primer and anti rust paint incld Cleaning, replacement of funal, minor repair and watering (On own arrangement) the earthing pits complete all as specified and directed. |
| 12 | M & L earth continuity conductorGI of 32x6 mm of GI strip by means of bolts, nuts, check nuts and GI washers complete all as specified. |
| 13 | M & L Synthetic insulating mat (rubber matting), ISI Marked suitable for 1100 Volts electrical grade 2mX1mX19mm thick chequered top, ISI marked to be laid in front of LT panel board complete all as specified and directed. |
| 14 | M&L for Danger notice boards of 1.6mm thick mild steel sheet, vitreous enamelled white,with letters, figures and conventional skull and bones in signal red colour and fixed with MS clamps, bolts, nuts and washers of approved size for LT/HT 25x20cm size. |
| 15 | S & F fuse wire (Tin & Copper) 16/18/20 SWG complete all as specified and as directed by Engr-in-Charge. |
| 16 | S&F in First Aid items/medicines i.e. Betadine-1, Dettol-01, Anteseptic medicinal tube for curing burnt skin-1,bandage-10, one sanitizer 100 Ml, Cotton-01, cotton Bandage-01 etc. with in a Plastic/ Steel box all complete and as specified by Engr.-in-charge. |
| 17 | Supply and fix energy efficient LED flood light 80W, Aluminium die cast housing luminarie with unique lense system for enhanced uniform illumination and thoughned glass with silicon gasket for IP gasket for IP 66 protection of Wipro Cat Pat No LF19-931-060-57-XX or equivalent in Philips / Crompton. PVC insulated FRLSH multistranded copper conductor cable 2.5 Sqmm - 02 runs upto 2 RM drawn through 20 MM dia poly propylyene felxible conduit pipe complete all as specified and directed by Engineer-in-Charge. |
| 18 | Suppy and fixing exhaust fan steelbody with louvers of size380 mm sweep, 900 RPM 230 volts single phase AC supply complete with, bolt, nuts and washers, suitably embedded in the wall including making suitable opening and provisioning of flexible cord copper of size 23/0.0076 from ceiling rose to exhaust fan for giving connection complete all as specified and directed by Engineer-in-Charge. |
| 19 | Suppy and fixing exhaust fan steelbody with louvers of size 450 mm sweep, 900 RPM 230 volts single phase AC supply complete with, bolt, nuts and washers, suitably embedded in the wall including making suitable opening and provisioning of flexible cord copper of size 23/0.0076 from ceiling rose to exhaust fan for giving connection complete all as specified and directed by Engineer-in-Charge. |
| 20 | Dismantaling of old worn out/rusted Fencing wire mesh/Barbed wire fence & Chain link fencing ofany type complete. |
| 21 | M&L forMS galvanised Chain link fencing, of size 55 mm x 55 mm aperuture made of 8 guage GI wire including line wires, any mesh, size and type to any type of standards, rails, straining bolts, etc complete all as specified and directed. |
| 22 | M&L for surafe excavation of soft/loose soil n exc (not exceeding) 30cm deep and averaging 15cm deep and getting out complete all as specified. |
| 23 | S&F Mild steel works as in posts and struts in fencing including cutting tops to shape as directed, drilling holes, notching for wire, etc. flat iron fillets (for securing wire mesh etc.) including all necessary drilling, bolting or riveting, locking arrangement, hinges etc., complete all as specified and directed. |
| 24 | S&F Mild steel screw bolts (machine made) with hexagonal or square heads at one end and screwed the other or screwed both ends, each screwed end to be fitted with washers and one hexagonal or square nut, n exc 5cm longand 10 mm diacomplete all as specified and directed. |
| 25 | S&F TMT 10 mm dia and over cut to lengths bent to shape required cranking including bending, hooking ends etc. and binding with mild steel wire (annealed) not less than 0.9 mm dia complete all as specified and directed. |
| 26 | S&F in replacement plates (plain or chequered) channels, square cut or notched (ordinary and counter sunk) forming holes, without any attachment Fe 410-W (Gde-E- 250) quality-A for cable duct in E/M installations all as specified and directed by Engr-in-Charge. |
| 27 | M & L for Painting steel surface over 10 cm in width or girth with two coats of 1st quality synthetic enamel paint of Black/ Yellow / silver over a coat of aluminium primer and anti rust paint incld Cleaning by sand papercomplete all as specified and directed. |
| 28 | Demolition of cement concrete (unreinforced) in ground floors and pavings n. exc 15 cm thickness (below or above GL) removal of rubbish/debries MD land. |
| 29 | Supply, spreading and levelling 40 mm graded crushed stone agg with laying of 250 micron polithene sheet in various EM installations all as directed by Engr-in-Charge |
| 30 | M&L Brickwork with sub class‘B’ bricks, straight or curved on plan exc 6m mean radius built in cement mortar 1:6 complete all as specified and directed by Engr-in-Charge. |
| 31 | M&L rendering 15mm thick in CM 1:4 to thebrick/concrete surface finishing the surface even and smooth with 2 Coats of white distemper paint complete all as specified and directed. |
AI Tender Summary
Tender Timeline
Jul 24, 2023
11:30 IST
Tender Published
Tender notice published.
CompletedAug 12, 2023
17:00 IST
Bid Submission Deadline
Online submission via eProcurement portal.
CompletedAug 14, 2023
Bid Opening Date
Technical bids will be opened and evaluated.
CompletedTender Documents
Download All (ZIP) ↓
Disclaimer
We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender