Tender For Provision Of 01 X 320 Kva Generator Set And Amf Panel For Generator Set And Special Repair To Ug Cables And Connected Items At Rajouri Of Age E / M Under Ge 862 Ews, Udhampur-Jammu And Kashmir

Military Engineer Services-MES has published Tender For Provision Of 01 X 320 Kva Generator Set And Amf Panel For Generator Set And Special Repair To Ug Cables And Connected Items At Rajouri Of Age E / M Under Ge 862 Ews. Submission Date for this Tender is 24-08-2023. Diesel Generators Tenders in Udhampur Jammu And Kashmir. Bidders can get complete Tender details and download the document.




Tender Notice

38799192
Corrigendum : Tender For Provision Of 01 X 320 Kva Generator Set And Amf Panel For Generator Set And Special Repair To Ug Cables And Connected Items At Rajouri Of Age E / M Under Ge 862 Ews
Open Tender
Indian
Jammu And Kashmir
Udhampur
24-08-2023

Tender Details

Provision Of 01 X 320 Kva Generator Set And Amf Panel For Generator Set And Special Repair To Ug Cables And Connected Items At Rajouri Of Age E / M Under Ge 862 Ews

Corrigendum Details

Sr No CorrigendumDate Corrignedum CorrigendumType NewSubmissionDate
1 17-Aug-2023 Bid Auto Extn Corrigendum Bid Auto Extn Corrigendum 24-08-2023

Key Value

Document Fees
INR 500 /-
EMD
INR 79000.0 /-
Tender Value
INR 39.50 Lakhs /-

BOQ Items

Name of Work:-Provn of 01 x 320 KVA Generator Set and AMF Panel for Generator Set and Special repair to UG cables and connected items at Rajouri of AGE E/M under GE 862 EWS
Sl. No. Item Description
1Supply, installation, testing and commissioning complete of OEM manufactured, static silent (sound proof enclosure) diesel Engine Driven generating set capable of delivering 320 KVA, Water cooled, 415 volts (AC three phase, 4 wire system of supply) 50 Hz at power factor 0.8 minimum. Engine as per IS:10001/ 10002 and Alternator as per IS: 13364 complete with relay panel and switch gears.The DG set shall consists of diesel engine coupled to a matching alternator, through flexible coupling and mounted on common base frame and complete with control panel standardised by manufacturer, fuel tank with mounting arrangements and inlet, outlet, return andinlet oil arrangement, exhaust pipe complete and suitable for conditions prevalent at Rajouri (J&K)(capacity of Engine, alternators shall be worked out taking all derating factors into consideration), with all provisions to operate through AMF panel & including PCC foundation of suitable size leaving at least 0.5 M all around for easy of movement and 0.5 M height, anti vibration pads, including all features to complete with latest CPCB guidelines and comprising of following :- (i) ENGINE (Prime Mover) : Diesel Engine 1500 RPM, direct injection type , confirming to ISO 3046 / BS 5514, Water cooled, naturally turbo charged, capable of giving adequate BHP to drive alternator capable of delivering 320 KVA at outdoor atmospheric conditions at Rajouri (J&K), ( Taking all derating factor into consideration), Dry cell battery ( Make: Exide / Amaron / HBL ) to be provided as per manufacturer recommendations with suitable bettery charger, electric battery start, complete with flywheel all standard fittings / fixtures as per manufacturer and including suitable panel with tachometer, lub oil, temperature, pressure gauge and frequency meters and also including self starter system, dynamo, fuel electric control panel with electronic speed governor (ECPG) and engine protection system (shut down, High water temperature, low lub oil, oil pressure, over speed etc) fuel tank, emergency stop button and first fill of lub oil and other consumables including Diesel for commisioning test etc.
2(ii) ACCOUSTIC ENCLOSURE :-Sheet metal fabricated cope type silent enclosure manufactured on CNC machines as per norms and powder coated after seven tank process, the enclosure shall be designed for reducing the sound level to 75 DB (A) at a distance of 1 M at 75% load under field condition. (iii) Foundation / Plinth / Base :Shall be providedas per manufactures recommendations, however minimum 0.5 M space should be available all around the set and height of plinth shall not be less than 0.5 M above ground level. (iv) Diesel storage tank of adequatecapacityfor storage of diesel for 12 hrs operation of Gen Set. (v) MISC : Tool kit, operation and maintenance catalogue, spare part list, overhauling manuals, guarantee card etc shall be provided as per manufacturer"s standard practices. (vi) ALTERNATOR :Brushless AC alternator, 3 phase, 415 volt, 4 wire, rated for output of 320 KVA, Minimum power factor 0.8, 1500 RPM, IP 65 protection class enclosure, insulation class “H” sailent pole, revolving field single bearing automatic voltage regulator coupled through flexible coupling with and to match the above engine.
3Supply,laying, jointing and testing,XLPE insulated, screened, PVC bedded, galvanized steel strip or wire armoured heavy duty electric cable with aluminium conductor 1100 volts grade of size 300 Sqmm 3.5 core laid in trenches, ducts, pipes, on poles and connection with necessary cables lugs, glands nut bolts complete after taking down old unserviceable cable all as specified and directed. (Note :- Excavation of earth work, removing, returning filling in, sand cushioning, brick protection cable cover and protection GI pipe shall be measured and paid separately and length of cable shall be one length unless otherwise as directed by GE).
4Excavating in trenches, n.exc 1.5m wide and n.exc 1.5m in depth in any type of soil for foundation, etc, or for laying of cables, n.exc 10 Sqm on plan and getting out, complete all as specified and directed.
5Returning, filling in, any type of soil, including spreading, levelling, watering and well ramming in layers not exceeding 25 cm thick ,complete all as specified and as directed.
6Removing excavated material ,not exceeding 50 m and depositing where directed at a level not exceeding 1.5 m above the starting point, complete all as specified and directed.
7M&L for dry sand cushioning to underground cable, provided with a layer 8 cm thick before and 15 cm deep after laying and stretching jointing and testing the cable complete all as specified and as directed. (Note: Punned thickness of sand shall be measured and paid).
8M&L for brick covering with width equal to length of brick as mechanical protection to cable using sub class ‘B’ bricks laid in trenches flat,size 230mm x 115mmx 75mm, complete all as specified and as directed.
9M&Lfor 40mm bore galvanized steel tubing (light grade) with complete all fittings such as elbow, unions, nipples, tees, bends, short pieces, connections, check-nuts, caps, plugs, diminishing pieces and flanges etc as in pole, crossing of roads, laid in trenches, fixed on walls for protection, completeall as specified and directed.
10M&Lfor earthing complete with galvanised steel earth plate electrode 600x600x6mm thick, burried directly in ground (earth pit not less than 2.25m deep below ground level) with top edge of the plate not less than 1.5m below normal ground level,connected to and including 32X6mm thick galvanised iron strip by means ofbolts, nuts, check nuts and washers of galvanised iron or steel all as specified in electrical plate No 3 of SSR (2009) part-I including 40mm bore GI pipe light grade for protection of earth strip and PCC 1:2:4 type B-1 as in pit, Precast RCC earth pit cover 8 cm thick reinforced with 8mm dia TMT bars @150mm c/c and two handles, excavation and earth work in any type of soil and alternate layers of charcoal, common salt and 20mm bore galvanised medium grade steel tubing for watering with one end fixed with cast iron funnel and wire mesh and testing on completion, complete all as specified and directed. (Note:-Earth strip and protection pipe upto test point is included in the rate quoted)
11S&F for change over switch, 4 pole, 415 Volts of rating 400 Amps, front handle operated type, on load type in sheet metal enclouser of 2mm thick CRCA sheet, powder coated wheather proof fixed on wall complete including connected to incoming and outgoing cables with suitable lugs, glands, nuts, bolts, and washers etc, completeall as specified and directed.
12Supply,laying, jointing and testing,XLPE insulated, screened, PVC bedded, galvanized steel strip or wire armoured heavy duty electric cable with aluminium conductor 1100 volts grade of size 70 Sqmm 3.5 core laid in trenches, ducts, pipes, on poles and connection with necessary cables lugs, glands nut bolts complete after taking down old unserviceable cable all as specified and directed. (Note :- Excavation of earth work, removing, returning filling in, sand cushioning, brick protection cable cover and protection GI pipe shall be measured and paid separately and length of cable shall be one length unless otherwise as directed by GE).
13Supply,laying, jointing and testing,XLPE insulated, screened, PVC bedded, galvanized steel strip or wire armoured heavy duty electric cable with aluminium conductor 1100 volts grade of size 25 Sqmm 3.5 core laid in trenches, ducts, pipes, on poles and connection with necessary cables lugs, glands nut bolts complete after taking down old unserviceable cable all as specified and directed. (Note :- Excavation of earth work, removing, returning filling in, sand cushioning, brick protection cable cover and protection GI pipe shall be measured and paid separately and length of cable shall be one length unless otherwise as directed by GE).
14Supply,laying, jointing and testing,XLPE insulated, screened, PVC bedded, galvanized steel strip or wire armoured heavy duty electric cable with aluminium conductor 1100 volts grade of size 16 Sqmm 2 core laid in trenches, ducts, pipes, on poles and connection with necessary cables lugs, glands nut bolts complete after taking down old unserviceable cable all as specified and directed. (Note :- Excavation of earth work, removing, returning filling in, sand cushioning, brick protection cable cover and protection GI pipe shall be measured and paid separately and length of cable shall be one length unless otherwise as directed by GE).
15S&F in replacement for change over switch, 4 pole, 415 Volts of rating 63Amps, front handle operated type, on load type in sheet metal enclouser of 2mm thick CRCA sheet, powder coated wheather proof fixed on wall including all fixing arrangement and connected to incoming and outgoing cables with suitable lugs, glands, nuts, bolts, and washers etc, complete all as specified and directed.
16S&F for LED secutity light fitting 35 watts, made in pressure diecast housing with eppoxy power coated dark graphite grey colour finish, parismatic polycarbonate cover with individual LED lense with IP 65 complete with all accessories and necessary fixing arrangement on wall / pole at any height including three core 0.5 sqmm copper cable from connector to fitting and after taking down old unserviceable light fittings of any type, completeall as specified and directed
17S&F for FRP looping box of size 325x220x150 mm with aluminium bus bar (02 Nos) 100 Amps capacity connector and comprising oF MCB SP 6 Amps, ISI marked 240 V, "C" series/curves complete with including providing GI calmps, nuts bolts etc suitable for fixing on PCC pole/wall etc and after taking down old unserviceable looping box of any type complete all as specified and directed.
18M&L for GI bracket pipe of size 40mm bore medium grade of 1.2 mtr long bent to shape hot or cold suitable for streetstreet light fitting and making the one end of GI pipe bracket suitable for fixing of street light fittings of any type and the GI bracket shall be fixed on wall/pole surfaces by providing suitable MS iron 25x4 mm clamps 2 Nos of suitable length, duly fixed to the bracket pipe and painting to MS clamps and fixing with necessary suitable nuts, bolts and washers and after taking down old unserviceable GI brakcet of any type complete all as specified and directed.
19S&F for copper conductor cable, PVC insulated, sheathed flexible, multistranded ISI marked 1100 volts grade 3 core 1.5 sqmm and including connection and testing and after taking down old unserviceable copper conductor cable, complete all as specified and directed.
20S&Ffor decorative LED Bollard light with cone shaped integral decorative with polycarbonate diffuser type LED Bollard light 9W, IP 65 lihgt including all accessories and connecting materials such as clamps, brackets, nut bolts reducer etc with base PCC 1:2:4 fixed on wall/floor and making electrical connection with copper cable, after taking down old unserviceable light fittings of any type, complete all as specified and directed.
21S&F in repair for post top lantern light fitting 35 watts with cast aluminium spigot lid cover and clear acrylic cover with IP65 protection complete with all accessories including fixing arrangement by providing GI pipe of suitable size and length as per site requirement and making good the distrubed portion to match with existing surface, after taking down old unserviceable light fittings of any type, completeall as specified and directed.
22S&F bus bar chamber panel out door type 3.15mm of suitable size with 4 strips 200 Amp bus bar aluminium along with MCCB of 125 Amp four pole adjustable type duly connected to aluminium strip at incoming side with suitable space for 2 incoming cables and outgoing of 2 cables, bus bar fixed on insulators in zig-zag position, clearance in each strip and clearance at both side should not be less than 125mm with sufficient working space, height of bus abr chamber not less than 1 mtr, mounted MS angle 50x6mm, made of CRCA sheet 2mm thick outdoor type powder coated both side opening shutter in two halves cable opening from bottom side with indicators RYB hinges through out the length of shutter with half turn locking arrangement, including grouting in PCC, after taking down old unserviceable bus bar chamber panel of any type, complete all as specified and directed. Note:Bus bar chamber panel of size 600x900x350mm.
23M&L in repairfor 50mm bore galvanized steel tubing (light grade) with complete all fittings such as elbow, unions, nipples, tees, bends, short pieces, connections, check-nuts, caps, plugs, diminishing pieces and flanges etc as in pole, crossing of roads, laid in trenches, fixed on walls for protection, completeall as specified and directed.
24Supply, intallation, testing and commissioning AMF Panel board suitable for 320 KVA Gen Set, working on 3 phase, 4 wire, 415 volts, AC, 50 Hz outdoor type, cubicle, floor mounted, free standing, dust and vermin proof, air ventilation, factory fabricated suitable for accommodating all accessories with following functions and facilities complete all as specified and directed by Engr-in-Charge. (a) Automatic and manual modes of operation with selector switch. (b) Auto operation after suitable time delay to switch the load to DG set if mains fail or one or more phases of mains is not available or low / high voltage beyond permissible limits. (c) Switch the load back to main suppply after suitable time delay when healthy main supply is restored and stopping the engine after prescribed duration by OEM. (d) Attempt to start the engine upto three times on failure of early attempts with suitable time intervals. (e) Fuel sensor system to display fuel level in the DG tank. (f) AMF relay should be easily programmable and should have facility for Rs. 232 and Rs. 485 communication interfaces. (g) Indicating lamps to indicate the status of DG set. (h) Inbuit battery of suitable size and its charging and monitoring system. (j) Automatic shutdown during DG fault. (k) Hooter / alarm annunciation system to start and emergency stop. (l) Two Nos of 4 pole MCCBs 400 Amp for incomers and all required power contractors and its control system. (m) All internal connections of control circuit with suitable size multistranded copper conductor cable. (n) Suitable meters and arrangements to display the parameters such as 3 Phase voltage, 3 Phase current, frequency, KWH of mains and DG set supplies, PF, DG running status and DG speed. (o) Foundation for AMF Panel shall be provided as per OEM recommendation and cost of the same shall be deemed to be including in the unit rate. Note: Cost of copper cable of suitable size including all connected accessories requried for connection of AMF Panel to DG Set shall be included in the quoted rate under this item.
Disclaimer :
We takes all possible care for accurate & authentic tender information, however Users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender.
Tell us about your Product / Services,
We will Find Tenders for you

Copyright © 2024 · All Rights Reserved. Terms of Usage | Privacy Policy

For Tender Information Services Visit : TenderDetail