Retender Electrical Installation Works For ( Gplus3 ) Model For Single 100 Bedded Covid Ward At Haldia Sd Hospital, In The District Of Purba Medinipur----Supply Installation Testing And Commissioning Of Hvac System With Negative Room Pressure System., haldia-West Bengal

Public Works Department-PWD has published Retender Electrical Installation Works For ( Gplus3 ) Model For Single 100 Bedded Covid Ward At Haldia Sd Hospital, In The District Of Purba Medinipur----Supply Installation Testing And Commissioning Of Hvac System With Negative Room Pressure System.. Submission Date for this Tender is 07-08-2023. Electrical Maintenance Tenders in haldia West Bengal. Bidders can get complete Tender details and download the document.




Tender Notice

38795187
Retender Electrical Installation Works For ( Gplus3 ) Model For Single 100 Bedded Covid Ward At Haldia Sd Hospital, In The District Of Purba Medinipur----Supply Installation Testing And Commissioning Of Hvac System With Negative Room Pressure System.
Open Tender
Indian
West Bengal
haldia
07-08-2023

Tender Details

Retender Electrical Installation Works For ( Gplus3 ) Model For Single 100 Bedded Covid Ward At Haldia Sd Hospital, In The District Of Purba Medinipur----Supply Installation Testing And Commissioning Of Hvac System With Negative Room Pressure System.

Key Value

Document Fees
Refer document
EMD
INR 81554.0 /-
Tender Value
Refer document

BOQ Items

Name of Work:EI works for (G+3) model for single 100 bedded covid ward at Haldia SD Hospital, in the district of Purba Medinipur----SITC of HVAC system with negative room pressure system.
Sl. No. Item Description
1Supply of Ceiling Mounted Ductable DX type Air Conditioning Unit with minimum 198000 btu/hr or higher Cooling capacity, minimum 6600 CFM or higher Air Flow, with 2 / 3 nos., Scroll compressor, 400V/3 PH/50 Hz Microprocessor based Controllerof minimum 16.5 TR or higher nominal capacity with R-32 / R-407 / R-410A Refrigerant. (Make : Hitachi /Daikin / Carrier /Voltas)
2Supply of Single Skin Centrifugal Cabinet Type Fan complete with DIDW- forward curved belt driven centrifugal blower Rotaion of fan 1760 RPM, Epoxy/ galvanized steel sheet cabinet with service access doors, Inlet & outlet drilled flanges 5.6 KW, 4 pole, IE - 2, IP -55 Standard 3Ph/415V/50 hz VFD Motor(Make: ABB/Cromptom) with Fixed base, common base frame with spring isolators,Flange at inlet and outlet are provided to facilitate duct connection necessary hanging/supporting members, water prof VFD Panel for Fan"s Speed control etc. Sound level-65 dba. Capacity 70mm/wc Static pressure, 7500 CFM, (Elta/Edgetech/VTS).
3SITC ofTreated Fresh Air arrangementwith multi stage filtration, Control damper, Actuator, complete with linkage control, Bird screen, etc.
4SITC of 10 Micron Pre Filter with Frame, it will be fitted on Centrifugal Exhust fan, TFA Units& on the Fresh air Damper (Make: Spectrum/ AFI).
5SITC of 10 Micron Fine Filter with Frame, it will be fitted on Centrifugal Exhust fan, TFA Units& on the Fresh air Damper (Make: Spectrum/ AFI).
6SITC of MERV-17 0.3 Micron Hefa Filter with minimum 450mm Depth, it will be fitted on Centrifugal Exhust fan.(Make: Spectrum/ AFI).
7Supply and fixing of UVC EMIITTER for the above fan"s for prevention of fungus , The minimum UV intensity in the coils shall be 700-800 UW-SEC/CM2. The unit shall be UL.Listed (UL-1995) to be fitted on Centrifugal Exhaust and IDUs.
8Installation, Testing & Commissioningof the aboveExhaust &Air Conditioning systems with all necessary accessiores for hanging Indoor & Outdoor Units
9For 16.5 TR Ductable Units.
10For 7500 CFM Centrifugal Exhaust system.
11Copper refrigeration pipe line for liquid and suctionline with hard drawn copper piping with supports &brackets
12Cu.HD Pipes Liquid line dia 12.7 mm .with 9mm thick nitrile insulation.
13Cu.HD Pipes Suction line dia 22.2 mm with 13mm thick nitrile insulation.
14Supply and fixing of necessary electrical arrangements of Air Conditioning Units, PVC insulated FRLS grade Copper cable for connection betweeen indoor and outdoor units, 1.1 KV grade.[FINOLEX / POLYCAB / RR KABEL]
157 core x 1.5 mm²
164 core x 6 mm²
17Supply & fixingof dia UPVC drain pipes with all necessary hanging arrangements & 9mm Heat Retardant Thermal insulutaion.
18Dia 32mm
19Dia 25mm
20SITCofSiteFabricated G.I Sheet Metal SquareAir Duct complete with Angle, Fastner, supports, dampers etc.as perspecifications & site requirement.
21For 24 SWG
22For 22 SWG
23For 20 SWG
24Supply and Fixing of Air Duct Insulation.
25Supply andfixingHeat Retardant closedcell Class"O" 9mm thk NitrileRubberinsulation inside Supply Air duct.
26Supply andfixingHeat Retardant closedcell Class"O" 9mm thk NitrileRubberinsulation with AI Foil Faced Outside Supply Air duct.
27Supply & Fixing of Air Diffuser With VCD. (Duct Bottom Surface Mounted)
28Supply & Fixing of Liner type AI Powder Coated Continuous Grill with VCD for Exhaust Air. (Duct Bottom Surface Mounted monted)
29Supply and Fixing ofMotorized Volume Control Damper.
30Supply and Fixing ofMotorized Non-Return Type Flow Control Damper .
31Supply & Fixing of Fusiable Link Fire Damper,Galvanized Steel Sheet with 125 GSM Zink Coated, Certified by CBRI ( U-555, 1995),with minimum fire rating not less than 120 min, must be Fusiable Link Spring with 74°C Temerature rating Ul Listed
32Providing and fixing fire retardantnonporous doublelayer flexibleconnectionbetween IDU, Exhaust, TFA units and duct.
33SITC of heavy duty anti vibrational pad to protect the system from any kind of unwanted vibration.
34Supply & Fixing of G.I Cable tray 50mmx 300mm x 50mm
35Lifting Shifting of Indoor and Outdoor units,TFA Units, Exhaust units, Scafolding, Minor Civil Work for mending the goodsand Carriage of Lowside materials
36Supplying, fabrication & fixing03 Nos. M.S. Angle/M.S C chanel of size (75 mm x 75 mmx6mm) for placingthe outdoor unitof ductablesplit AC incl. drilling 05 nos holes in each Angle including cutting holes into the wall & grouting the same (1:1 ½ :3) etc for Air Conditioning Units
37Supplying, fabrication & fixing 4 Nos. M.S u-channel of 6 mm thick of size (75 mm x 40 mm x 40 mm) for making Base Frame table type for installation of Exhaust Cabinet incl. drilling 2 nos holes in each channel. fabricated with 4 Nos.Baricated the same for maintenance horizontal angle of 50 mm x 50 mm x 6 mm Inscl Platform as per direction of E.I.C.. Area of Platform 9mtr x 1.8mtr for Placing the Exhaust Units & TFA.