}

Kiifb-Construction Of Sub RegistrarS Office, Thiruvallam-Electrification-General Electrical Work, Thiruvananthapuram-Kerala

Kerala State Construction Corporation Ltd has published Kiifb-Construction Of Sub RegistrarS Office, Thiruvallam-Electrification-General Electrical Work. Submission Date for this Tender is 31-07-2023. Electrical Maintenance Tenders in Thiruvananthapuram Kerala. Bidders can get complete Tender details and download the document.




Tender Notice

38785385
Kiifb-Construction Of Sub RegistrarS Office, Thiruvallam-Electrification-General Electrical Work
Open Tender
Indian
Kerala
Thiruvananthapuram
31-07-2023

Tender Details

Kiifb-Construction Of Sub RegistrarS Office, Thiruvallam-Electrification-General Electrical Work

Key Value

Document Fees
INR 2760 /-
EMD
INR 34673.0 /-
Tender Value
INR 13.86 Lakhs /-

BOQ Items

Work Name:KIIFB-Construction of Sub Registrar"s office, Thiruvallam-Electrification-General Electrical Work
Sl. No. Item Description
1Estimate
2OD71808/2023-2024:Supply and wiring points according to IS 732-1989 using rigid PVC medium conduit of minimum size 20 mm with specials conforming to IS 9537 part III 1983 and with suitable size specials conforming to IS 3419-1988, cutting the walls, fixing the conduit concealed suitably and with 1.50 sq mm FRLS PVC insulated stranded single core copper conductor cable 650V grade, including providing switch board main and continuous earthing with 1.50 sq mm green coloured FRLS PVC insulated stranded single core copper conductor cable 650V grade, required quantity of copper earth socket, brass bolt and nut crimping/ soldering etc complete with suitable size modular type metal switch boxes, modular type front plates (white) etc. up to and including 6A modular type SP switches and making good the surface of wall, colour washing etc. complete. All the terminations in the switch boards and DB"s shall be tinned and the wires shall be drawn and fixed along the periphery of the box using suitable ties, tie mounts etc as required. (RoHS compliant modular accessories).Single Control light point with 6A, plate ceiling rose - Short point
3OD71809/2023-2024:Supply and wiring points according to IS 732-1989 using rigid PVC medium conduit of minimum size 20 mm with specials conforming to IS 9537 part III 1983 and with suitable size specials conforming to IS 3419-1988, cutting the walls, fixing the conduit concealed suitably and with 1.50 sq mm FRLS PVC insulated stranded single core copper conductor cable 650V grade, including providing switch board main and continuous earthing with1.50 sq mm green coloured FRLS PVC insulated stranded single core copper conductor cable 650V grade, required quantity of copper earth socket, brass bolt and nut crimping/ soldering etc complete with suitable size modular type metal switch boxes, modular type front plates (white) etc. up to and including 6A modular type SP switches and making good the surface of wall, colour washing etc. complete. All the terminations in the switch boards and DB"s shall be tinned and the wires shall be drawn and fixed along the periphery of the box using suitable ties, tie mounts etc as required. (RoHS compliant modular accessories). Twin Control light point with 6A, plate ceiling rose - Short point
4OD71810/2023-2024:Supply and wiring points according to IS 732-1989 using rigid PVC medium conduit of minimum size 20 mm with specials conforming to IS 9537 part III 1983 and with suitable size specials conforming to IS 3419-1988, cutting the walls, fixing the conduit concealed suitably and with 1.50 sq mm FRLS PVC insulated stranded single core copper conductor cable 650V grade, including providing switch board main and continuous earthing with 1.50 sq mm green coloured FRLS PVC insulated stranded single core copper conductor cable 650V grade, required quantity of copper earth socket, brass bolt and nut crimping/ soldering etc complete with suitable size modular type metal switch boxes, modular type front plates (white) etc. up to and including 6A modular type SP switches and making good the surface of wall, colour washing etc. complete. All the terminations in the switch boards and DB"s shall be tinned and the wires shall be drawn and fixed along the periphery of the box using suitable ties, tie mounts etc as required. (RoHS compliant modular accessories). Single control light point without ceiling rose - Short point
5OD71811/2023-2024:Supply and wiring points according to IS 732-1989 using rigid PVC medium conduit of minimum size 20 mm with specials conforming to IS 9537 part III 1983 and with suitable size specials conforming to IS 3419-1988, cutting the walls, fixing the conduit concealed suitably and with 1.50 sq mm FRLS PVC insulated stranded single core copper conductor cable 650V grade, including providing switch board main and continuous earthing with 1.50 sq mm green coloured FRLS PVC insulated stranded single core copper conductor cable 650V grade,required quantity of copper earth socket, brass bolt and nut crimping/ soldering etc complete with suitable size modular type metal switch boxes, modular type front plates (white) etc. up to and including 6A modular type SP switches and making good the surface of wall, colour washing etc. complete. All the terminations in the switch boards and DB"s shall be tinned and the wires shall be drawn and fixed along the periphery of the box using suitable ties, tie mounts etc as required. (RoHS compliant modular accessories).Single control ceiling fan point with 6 A, 3 plate ceiling rose & with socket size stepped electronic regulator. - Short point
6OD71812/2023-2024:Supply and wiring points according to IS 732-1989 using rigid medium gauge PVC conduit of minimum size 20 mm with specials conforming to IS 9537 part III 1983 and with suitable size specials conforming to IS 3419-1988, cutting the walls, fixing the conduit concealed suitably and with 1.50 sq mm FRLS PVC insulated stranded single core copper conductor cable 650V grade, including providing switch board main and continuous earthing with 1.50 sq mm green coloured FRLS PVC insulated stranded single core copper conductor cable 650V grade, required quantity of copper earth socket, brass bolt and nut crimping/ soldering etc complete with suitable size modular type metal switch boxes, modular type front plates (white) etc. up to and including 6A modular type SP switches and making good the surface of wall, colour washing etc. complete. All the terminations in the switch boards and DB"s shall be tinned and the wires shall be drawn and fixed along the periphery of the box using suitable ties, tie mounts etc as required. (RoHS compliant modular accessories). Call bell point with 6 A bell push at one end and 6 A, 3 plate ceiling rose at other end - Short point
7OD71813/2023-2024:Supply and wiring points according to IS 732-1989 using rigid PVC medium conduit of minimum size 20 mm with specials conforming to IS 9537 part III 1983 and with suitable size specials conforming to IS 3419-1988, cutting the walls, fixing the conduit concealed suitably and with 1.50 sq mm FRLS PVC insulated stranded single core copper conductor cable 650V grade, including providing switch board main and continuous earthing with 1.50 sq mm green coloured FRLS PVC insulated stranded single core copper conductor cable 650V grade, required quantity of copper earth socket, brass bolt and nut crimping/ soldering etc complete with suitable size modular type metal switch boxes, modular type front plates (white) etc. up to and including 6A modular type SP switches and making good the surface of wall, colour washing etc. complete. All the terminations in the switch boards and DB"s shall be tinned and the wires shall be drawn and fixed along the periphery of the box using suitable ties, tie mounts etc as required. (RoHS compliant modular accessories). Combined plug point with 6 A, 5 pin plug socket controlled by 6 A, switch in the same switch board as that of light points
8OD71814/2023-2024:Supply and wiring points according to IS 732-1989 using rigid PVC medium gauge conduit of minimum size 20 mm with specials conforming to IS 9537 part III 1983 and with suitable size specials conforming to IS 3419-1988,cutting the walls, fixing the conduit concealed suitably and with 1.50 sq mm FRLS PVC insulated stranded single core copper conductor cable 650V grade, including providing switch board main and continuous earthing with 1.5 sqmm green coloured FRLS PVC insulated stranded single core copper conductor ,required quantity of copper earth socket, brass bolt and nut crimping/ soldering etc complete with suitable size modular type metal switch boxes, modular type front plates (white) etc. up to and including 6A modular type SP switches and making good the surface of wall, colour washing etc. complete. All the terminations in the switch boards and DB"s shall be tinned and the wires shall be drawn and fixed along the periphery of the box using suitable ties, tie mounts etc as required. (RoHS compliant modular accessories). Independent plug - Short point
91.21.1:Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/ recess including cutting the wall and making good the same in case of recessed conduit as required.20 mm
101.21.2:Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/ recess including cutting the wall and making good the same in case of recessed conduit as required.25 mm
111.27.1:Supplying and fixing following size/ modules, GI box alongwith modular base & cover plate for modular switches in recess etc as required.1 or 2 Module (75mmX75mm)
121.27.2:Supplying and fixing following size/ modules, GI box alongwith modular base & cover plate for modular switches in recess etc as required.3 Module (100mmX75mm)
131.27.4:Supplying and fixing following size/ modules, GI box alongwith modular base & cover plate for modular switches in recess etc as required.6 Module (200mmX75mm)
141.27.5:Supplying and fixing following size/ modules, GI box alongwith modular base & cover plate for modular switches in recess etc as required.8 Module (125mmX125mm)
151.17.3:Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface / recessed steel/ PVC conduit as required.3 X 1.5 sq.mm
161.17.6:Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface / recessed steel/ PVC conduit as required.6 x 1.5 sq. mm
171.17.12:Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface / recessed steel/ PVC conduit as required.3 x 2.5 sq. mm
181.17.30:Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface / recessed steel/ PVC conduit as required.3 x 6 sq. mm
191.18.2:Supplying and drawing following pair 0.5 mm dia FRLS PVC insulated annealed copper conductor,unarmored telephone cable in the existing surface/ recessed steel/ PVC conduit as required.2 Pair
201.24.1:Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.5/6 amps switch
211.24.3:Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.15/16 amp switch
221.24.4:Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.3 pin 5/6 amp socket outlet
231.24.5:Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.6 pin 15/16 amp socket outlet
241.24.6:Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.Telephone socket outlet
251.24.7:Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.TV antenna socket outlet
261.26:Supplying and fixing modular blanking plate on the existing modular plate & switch box excluding modular plate as required.
271.22.1:Supplying and fixing metal box of following sizes (nominal size) on surface or in recess with suitable size of phenolic laminated sheet cover in front including painting etc as required.75 mm X 75 mm X 60 mm deep
2890.5.1.3:Supply and fixing the following types of superior quality 250V A.C call bell on existing M.S. box and giving connections with required length of 3 core, 16 / 0.20mm 650/1100V grade PVC insulated and PVC sheathed round copper conductor flex wire conforming to relevant ISS or with the extended original wiring, earthing the MS box and making good the surface as required.Ding dong bell
2990.3.18.2:Supply, fabrication, conveyance and fixing the following sizes of B class GI pipe bent to shape / cut and welded to shape and fixing the same to wall / parapet using clamps as noted along with each size, painting with 2 coats of synthetic enamel paint over a coat of zinc chromate primer, making good the damages, colour washing etc as required.32 mm dia with HG company fabricated clamps
3090.3.20.3:Supply & installation of light fittings on TW round block Supply, conveyance installation testing and commissioning the light fittings of following types made of CRCA with 0.5mm thicknesscomplete with all accessories andlamps etc. directly on wall or ceiling with PVC round block neatly painted to suit the fitting and giving connection with required length of 16/0.20mm 3 core copper conductor flex wire conforming to relevant ISS and giving connections as required.1200 mm 1X20W LED Lamp with box type fixture
3190.3.21.3:Supply & installation of light fittings on "C/U" shaped flat iron bracket Supply, conveyance, installation, testing and commissioning the light fittings of following types made from 0.5mm CRCA sheet complete with all accessories andlamps etc. directly on wall using 2 nos. "C/U" brackets made from 20 x 3 mm MS flat, painting the flat iron bracket and giving connections with required length of 16/0.20mm 3 core copper conductor flex wire conforming to relevant ISS or extending the original wiring and giving connection etc. as required.1200 mm 1X20W LED Lamp with box type fixture
3290.15.4.1:Supply Conveyance, installation, testing and commissioning of 20W LED street light output greater than 105lumen/W 4000-6000 K with IP 66 protection LED Chip make Cree/Lumilled/Nichea with power factor greater than 0.95 at full load, internal surge protection up to 8 KV,and Aluminium pressure die-cast Powder coated housing,acrylic cover complete with THD Less than10%, power factor greater than 0.98, RoHS compliant, duly wired up for use on 230 V AC supply. Driver compartment should be seperatly accessible for maintenance (LM 79&80 certificates from NABL accredited Third party lab to be produced mentioning chip manufacturer)
33OD71815/2023-2024:Supply and fixing low glare high efficiency square surface mounted LED flat panel 230V 50Hz 36 w light fitting complete with all required accessories etc. as required
34OD71816/2023-2024: Supply and fixing cast aluminium stove enameled bulk head fitting with deep drawn anodised aluminium body, epoxy powder coated, heat resistant prismatic glass cover suitable for 9 W LED light to wall / ceiling including giving connections with required length of 16/0.20mm PVC insulated and PVC sheathed 3 core round copper conductor flex wire conforming to relevant ISS or extending the original wiring and making good the surface as required.
35OD71817/2023-2024:Supply and fixing angle / straight brass lined skirt type, bakelite batten holder with aluminium shade, 9W LED bulb and giving connection etc as required
3690.4.1:Supply and installation of suitable size MS rod type fan clamp in the RCC slab as per IS 732 as required.
3790.4.5.2:Supply, conveyance, installation, testing and commissioning of ceiling fans of the following sizesusing standard accessories excluding resistance type regulator, wiring the down rod with 16/0.20mm PVC insulated and PVC sheathed 650/1100V grade 3 core round copper conductor flex wire or with extended original wiring etc. as required. Supply, conveyance, installation, testing and commissioning of ceiling fans of the following sizesusing standard accessories excluding resistance type regulator, wiring the down rod with 16/0.20mm PVC insulated and PVC sheathed 650/1100V grade 3 core round copper conductor flex wire or with extended original wiring etc. as required.1200mm sweep -5star rated ceiling fan complete with 300mm down rod , canopies, shackeles and blades and resistance type regulator working on 230V/240V single phase A/C
3890.4.8:Charges for cutting holes suitable for accommodating exhaust fans up to 305mm sweep including plastering colour washing etc. as required.
39OD71818/2023-2024:Supply, conveyance, installation, testing and commissioning of 225mm light duty exhaust fan in metal frame in the existing opening, fixing necessary bolt and nuts, making good the damages etc. as required including giving connections with required length of 24/0.20mm PVC insulated and PVC sheathed 3 core round copper conductor flex wire conforming to relevant ISS.
4090.9.2.1:Supply and fixing 100 x 50 mm PVC Cable Management System with base and lid along with the following accessories conforming to IEC 61084/ BS 476 & 4678 on surface / recessincluding cutting the wall and making good the damages in case of recessed installation as required.100 x 50 mm CMS with base and lid
4190.9.2.2:Supply and fixing 100 x 50 mm PVC Cable Management System with base and lid along with the following accessories conforming to IEC 61084/ BS 476 & 4678 on surface / recessincluding cutting the wall and making good the damages in case of recessed installation as required.Cable devider
4290.9.2.3:Supply and fixing 100 x 50 mm PVC Cable Management System with base and lid along with the following accessories conforming to IEC 61084/ BS 476 & 4678 on surface / recessincluding cutting the wall and making good the damages in case of recessed installation as required.External angle 90 degree
4390.9.2.4:Supply and fixing 100 x 50 mm PVC Cable Management System with base and lid along with the following accessories conforming to IEC 61084/ BS 476 & 4678 on surface / recessincluding cutting the wall and making good the damages in case of recessed installation as required.Flat angle 90 degree
4490.9.2.5:Supply and fixing 100 x 50 mm PVC Cable Management System with base and lid along with the following accessories conforming to IEC 61084/ BS 476 & 4678 on surface / recessincluding cutting the wall and making good the damages in case of recessed installation as required.Internal angle 90 degree
4590.9.2.7:Supply and fixing 100 x 50 mm PVC Cable Management System with base and lid along with the following accessories conforming to IEC 61084/ BS 476 & 4678 on surface / recessincluding cutting the wall and making good the damages in case of recessed installation as required.Flat cross
4690.9.2.8:Supply and fixing 100 x 50 mm PVC Cable Management System with base and lid along with the following accessories conforming to IEC 61084/ BS 476 & 4678 on surface / recessincluding cutting the wall and making good the damages in case of recessed installation as required.End cap
4790.9.2.10:Supply and fixing 100 x 50 mm PVC Cable Management System with base and lid along with the following accessories conforming to IEC 61084/ BS 476 & 4678 on surface / recessincluding cutting the wall and making good the damages in case of recessed installation as required.Joint cover
4890.9.2.11:Supply and fixing 100 x 50 mm PVC Cable Management System with base and lid along with the following accessories conforming to IEC 61084/ BS 476 & 4678 on surface / recessincluding cutting the wall and making good the damages in case of recessed installation as required.Cable retainer
4990.9.2.12:Supply and fixing 100 x 50 mm PVC Cable Management System with base and lid along with the following accessories conforming to IEC 61084/ BS 476 & 4678 on surface / recessincluding cutting the wall and making good the damages in case of recessed installation as required.1 to 3 module mounting box
5090.9.2.13:Supply and fixing 100 x 50 mm PVC Cable Management System with base and lid along with the following accessories conforming to IEC 61084/ BS 476 & 4678 on surface / recessincluding cutting the wall and making good the damages in case of recessed installation as required.4 to 5 module mounting box
51OD71819/2023-2024:Supply, testing and installation of Jack Cat6 Keystone UTP with Collapsible Shutter-White Make - D Link NKJ-C6WHI1B21 or equivalent
52OD71820/2023-2024:Supply, testing and installation of Face Plate-Single(Keystone jack, square) Make - D Link NFP-OWHI11 or equivalent
53OD71821/2023-2024:Supply, testing and installation of Back Box Make - D Link NBB-011 or equivalent or equivalent
541.53.1:Supplying and drawn of UTP 4 pair CAT 6 LAN cable in the existing surface/recessed steel/PVC conduit as required1 run of Cable
5590.10.1.1:Supply & Fixing the following types/ sizes of boxes suitable for modular accessories in surface/ recess including making good the damages, colour washing etc as required (RoHS compliant )1 module moulded plastic box on surface
5690.10.1.3:Supply & Fixing the following types/ sizes of boxes suitable for modular accessories in surface/ recess including making good the damages, colour washing etc as required (RoHS compliant )3 module moulded plastic box on surface
5790.10.1.5:Supply & Fixing the following types/ sizes of boxes suitable for modular accessories in surface/ recess including making good the damages, colour washing etc as required (RoHS compliant )6 module moulded plastic box on surface
581.28.1:Supplying and fixing following Modular base & cover plate on existing modular metal boxes etc. as required.1 or 2 Module
591.28.2:Supplying and fixing following Modular base & cover plate on existing modular metal boxes etc. as required.3 Module
601.28.4:Supplying and fixing following Modular base & cover plate on existing modular metal boxes etc. as required.6 Module
6190.11.1.15:Supply and installation ofsheet steel, phosphatised and painted, dust and vermin proof enclosure of MCB DB including copper /brass bus bar, neutral link, earth bus and DIN rail suitable for fixing MCB/isolator etc. fixed on wall using suitable anchor bolts or fixed in recess including cutting hole on the wall , making good the damages, colour washing etc. as required6 way (8+18) - double cover TPN vertical DB with provision for fixing 4P MCB / Isolator/ RCCB/ RCBO as incomer and SP/ TP MCB as outgoing (IP 42/43)
6290.11.1.16:Supply and installation ofsheet steel, phosphatised and painted, dust and vermin proof enclosure of MCB DB including copper /brass bus bar, neutral link, earth bus and DIN rail suitable for fixing MCB/isolator etc. fixed on wall using suitable anchor bolts or fixed in recess including cutting hole on the wall , making good the damages, colour washing etc. as required8 way (8+18) - double cover TPN vertical DB with provision for fixing 4P MCB / Isolator/ RCCB/ RCBO as incomer and SP/ TP MCB as outgoing (IP 42/43)
632.3.3:Supplying and fixing following way, single pole and neutral, sheet steel, MCB distribution board, 240 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCBIRCCB/Isolator12 way, Double door
642.10.1:Supplying and fixing 5 amps to 32 amps rating, 240/415 volts, "C" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required.Single pole
652.10.4:Supplying and fixing 5 amps to 32 amps rating, 240/415 volts, "C" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required.Triple pole
662.11:Supplying and fixing single pole blanking plate in the existing MCB DB complete etc. as required.
672.12.1:Supplying and fixing following rating, double pole, 240 volts, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required.40 amps
682.13.1:Supplying and fixing following rating, four pole, 415 volts, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required.40 amps
692.14.1:Supplying and fixing following rating, double pole, (single phase and neutral), 240 volts, residual current circuit breaker (RCCB), having a sensitivity current upto 300 milliamperes in the existing MCB DB complete with connections, testing and commissioning etc. as required.25 amps
702.15.1:Supplying and fixing following rating, four pole, (three phase and neutral), 415 volts, residual current circuit breaker (RCCB), having a sensitivity current upto 300 milliamperes in the existing MCB DB complete with connections, testing and commissioning etc. as required.25 amps
712.15.2:Supplying and fixing following rating, four pole, (three phase and neutral), 415 volts, residual current circuit breaker (RCCB), having a sensitivity current upto 300 milliamperes in the existing MCB DB complete with connections, testing and commissioning etc. as required.40 amps
722.16:Supplying and fixing DP sheet steel enclosure on surface/ recess along with 25/32amps 240 volts "C" curve DP MCB complete with connections, testing and commissioning etc. as required.
7390.12.7.40:Supply, laying and clamping of 1 no. PVC insulated and PVC sheathed armoured aluminium power cable, 1.1 KV grade of the following sizes using clamps noted along with the cables, spacing of clamps not exceeding 60cms, making good the damages , colour washing etc. as required.4 core 10 sq mm with factory made clamp
7490.12.7.41:Supply, laying and clamping of 1 no. PVC insulated and PVC sheathed armoured aluminium power cable, 1.1 KV grade of the following sizes using clamps noted along with the cables, spacing of clamps not exceeding 60cms, making good the damages , colour washing etc. as required.4 core 16 sq mm with factory made clamp
7590.12.24.4:Supply of superior quality copper tubular cable socket and making core termination of cables of the following sizes including crimping etc. as required.10 sq mm
7690.12.24.5:Supply of superior quality copper tubular cable socket and making core termination of cables of the following sizes including crimping etc. as required.16 sq mm
779.1.32:Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.4 X 10 sq. mm (25mm)
789.1.33:Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.4 X 16 sq. mm (28mm)
79OD71822/2023-2024:Supplying and providing earth clamps for siemens/ tripodular type cable glands of suitable length and other dimensions noted along with each size of glands for 4sqmm-16 sq mm sizes of cables with 12 mm wide x 1 mm thick clip as required.
8090.16.1.3:Supply and drawing bare earthing conductors of the following sizes along with wiring/ cables and giving connection as required3.15 mm copper conductor ( 10 SWG)
815.4:Earthing with G.I. earth plate 600 mm X 600 mm X 6 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 metre long etc. with charcoal/ coke and salt as required.
82OD71823/2023-2024:Supply and laying bare earthing conductors of size3.15 mm copper conductor (10 SWG) laid 0.6 m below ground level including excavating trench of suitable size and refilling etc. as required (in ordinary soil).
83OD71824/2023-2024:Supply and providing 25 x 3 mm GI strip earth lead from the test joint to the earth electrode using the following sizes of conductors/ strips including cutting, drilling necessary holes (in case of strip) and fixing firmly with plate test joint etc as required.
84OD71825/2023-2024:Supply and providing test joint for the earthing system using 2 Nos of 2x25x3mm of GI strip including cutting and bending to shape, drilling necessary holes and fixed to the watering pipe etc as required.
85OD71826/2023-2024:Supply and providing 25 x 6 mm brass bolt & nut with washers on the existing MS box / earth bus etc. as required including drilling necessary holes as required
86OD71827/2023-2024:Supply and providing 25 x 3 mm brass bolt & nut with washers on the existing MS box / earth bus etc. as required including drilling necessary holes as required
87OD71828/2023-2024:Supply and providing 12 x 3 mm brass bolt & nut with washers on the existing MS box / earth bus etc. as required including drilling necessary holes as required
8890.16.2.2:Supply and laying of the following sizes of B class GIpipe laid 0.6 m below ground level including excavating trench of suitable size and refilling etc, as required.20 mm dia. G.I pipe ( medium class)
8990.16.5.3:Supply of superior quality copper earth socket for the following size of earth conductor including crimping etc. as required.3.15 mm (10 SWG)
902.1.2:Providing and fixing following capacity TP&N disconnector fuse switch unit inside the existing panel board with ISI marked HRC fuses including drilling holes in cubicle panel, making connections, etc. as required.63 Amp TP & N
91OD71829/2023-2024: Fabricating and fixing enclosure for 63 Amps TP&N dis-connector fuse switch unit with handle assembly and HRC fuse as required.
92OD71830/2023-2024:Supply, testing and installation of 1 phase 1 HP submersible open well pump & motor with head range 20-40 mtrs having maximum flow rate of 90 LPH at 25 Mtrs and necessary accesories excluding pipe and extra length of wire (make Texmo/Crompton/Kirloskar/CRI)
93OD71831/2023-2024:Supply, testing and installation of single phase 1/2 HP mono block open well pump (CRI / Texmo)
9490.6.6.2:Supply and drawing FRLS PVC insulated & sheathed 650/1100 V grade 3 core copper conductor flat cable for submersible pump motor conforming to IS 694 part I 1990 as required including giving necessary connections of the following sizes.2.50 sq mm
9590.12.10.2:Supply & laying of DWC pipe in ordinary soil 0.75m below ground level including excavation50/38 mm or nearest size
96OD71832/2023-2024:63 A, 415 V, DIN type fuse base
97OD71833/2023-2024:Supply and fixing 63 A, 415 V, 2 way neutral link mounted on DMC/ SMC base
98OD71834/2023-2024:Supply and fixing 2 -80A, DIN type fuse link of size in the existing meter board and giving connections etc.
99OD71835/2023-2024:Supply and Installation / Fixing / Provision of Outdoor type HENSEL make (600X300x214 mm Mi 2410) suitable to fix Single Phase / Three Phase Energy Meter in suitable base plate and having a provision for Fuse / MCB cutout with complete tamper proof SEALING facility.
100OD71836/2023-2024:Supply and clamping the following sizes of "B" class GI pipe on wall with all required accessories & clamps etc., including cutting and making good the walls, painting the exposed portions etc.,asprotective covering to earth leads / cables/service entry pipe
101OD71837/2023-2024:Supply & providing First Aid Chart duly framed and placed ina conspcious location for clear vision
102OD71838/2023-2024: Supply and providing 5 Kg. Dry Chemical Powder type Fire Extinguisher with hose and clamps including fixing it to wall as required.
103OD71839/2023-2024:Painting letters or figures of size 2.50 cm, 4 cm or 5 cm height with enamel paint as identification mark to SB, DB, panel board etc as required
104OD71840/2023-2024:Supply, installation, testing and commissioning of Dumb Waiter 100 kgs capacity with the following specifications: 1. Speed - 0.25m/second 2. Type of drive - Single speed 3. Machine motor unit - 3 phase induction motor 415V 4. Location of machine room - Above lift well 5. Travel - Apprx. 4 metre 6. Serving - 2 floors, 2 opening 7. Power supply - 415V 3 phase 50 hz AC 8. Car enclosure : SS hairline finish 9. Car size - 700mm W x 700mm D x 800mm H 10. Flooring - Anti skid PVC flooring 11. Car entrance - Vertical Bi parting door SS 700 mm x 800 mm 12. Landing entrance - Vertical Bi parting door SS 700 mm x 800 mm 13. Type of controller - Micro Processor Down Collective 14. Special features : Stainless steel face plate for landing, Push button and floor position indicators for landings Machine Components Worm gear consisting of worm wheel of centrifugally cast bronze and worm of specially forged steel. Worm wheel to be coupled to specially designed motor suitable for elevator duty. Arrangement for releasing the brake manually and bringing the car to the nearest floor by a hand wheel/fly wheel to be provided. Structural steel ca frame to support the car platform and enclosure to be provided with suitable safety grar fixed underneath the frame. Control board with enclosure to be installed in the machine room. Automatic door operation consisting of a motor operated device on elevator car for smooth and quiet opening and closing of can and landing doors simultaneously to be provided. A fixed cam to be provided on top of elevator. Guide rails to be of machined ground steel T - section with suitable fixing arrangement and counter weight of structural steel frame loaded with appropriate filler wrights to be provided. Steel wire ropes for suspension to be provided. Special steel/ oil buffers to be provided as per standard design. Electro mechanical locks to be provided for each landing doors and should have mechanical interlocking with built in electric contacts. Electric cable/ wiring to be provided as per design and car name plate to be fitted on car indicating elevator capacity.
105OD71841/2023-2024:Supply and installation of High Pressure Water Mist and CAF Fire extinguisher back pack 9L capacity with Fire rating of 55A, 233B, 1000V with Special AFFF Compound with Pressure Vessel and Cylinder made of Ultralight Carbon composite material , Fire rating 55A, 233B, 1000V with one spare compressed Air Cylinder 2 Litre x 300 bar (Ultralight carbon composite with PET Liner), 10 Nos. O-rings for pressure vessel, one can 5 Litre special AFFF compound and one tool kit. Total weight 20kg and nozzle weight 750 grams.SPECIFICATIONSGENERIC1.Conformity to EN 3-7:2004+A1:2007-08 standards The complete system shall be tested for compliance from an internationally/nationally accredited laboratory for compliance to all 29 clauses (3.2, 3.15, 4.2, 4.3, 4.4, 4.5, 6.1, 6.2, 6.3, 7.1.1, 7.1.2, 7.2, 7.3, 7.4, 8.1, 8.2, 9.2, 10.1, 10.2, 10.4, 10.5, 10.6.1 & 10.6.2, 14.1, 14.2, 15.2, 15.3, 16.1, 16.2) of EN 3 - 7:2004 + Al: 2007-08 (E) Standard mandatorily applicable for the complete system.2.Mounting Type: Backpack3.Configuration : Shall be mounted on a sturdy frame suitably cushioned for comfort, provided with shoulder pads for carrying as a backpack and a handle to be carried by hand. All materials used shall be of fire retardant type. Backpack shall be supplied with two air cylinders.4.Main Components: Pressure vessel to hold the media with safety valve, compressed air cylinder coupled with a reducer, hose pipes for discharge of water mist media, extinguishing gun.Constructional1.Air Cylinder Material should be Ultralight Carbon composite with PET Liner2.Type of Foam should be Special AFFF Compound conforming to manufacturer own specifications for higher fire rating A55, B233, Spreading coefficient for special AFFF Compound shall be +5 minimum, concentration shall be 6%.3.Commercial Brand Name of the Special foam (fire extinguishing medium) as per accredited laboratory test report wherein higher fire ratings i.e A55,B233, E1000 V (Die Electric Suitability) achieved, to be declared in the single Test Report of complete system.4.Characteristics of extinguishing medium of Special AFFF Compound (manufacturer own specifications) with infrared spectrogram to be furnished like Density, Viscosity, pH factor, Refractive index at 20 ± 2deg C.5.Pressure Vessel Material & Capacity (Nominal Charge) should be Ultralite Carbon Composite with PET Liner of 9 liter capacity to be drawn by accredited test report.6.Extinguishing gun material should be stainless steel7.Extinguishing gun weight should 750 grams approx.8.Length of EN marked Hose should be 1.3 meter for backpack system9.Weight of fully charged Backpack system below 20 kg having Ultralite Carbon Composite with PET Liner Vessel.PERFORMANCE1.Air Cylinder Capacity (Ltrs) should be 2 Liters2.Air Cylinder pressure (Bar) 300 bar3.High Pressure Type Dynamic Operating pressure to be tested in the accredited laboratory test report which will be considered as high pressure as per clause No. 3.15 of EN 3 - 7:2004 + Al: 2007-08 (E) Standard. > = 35 for Ultralite Carbon Composite with PET Liner vessel4.Lancing Distance of Gun: should be 12 meter approx.5.The air hoses shall be suitable for minus 40 deg C to 100 Deg C temperature and EN mark on hose6.Minimum operating time in full throttle for Ultralight Carbon composite with PET Liner vessel should be 29 seconds7.System shall be designed for maximum operating temperature TS max and minimum operating temperature TS min of 60 deg C or more and 5 Deg C or less respectively and certified by the manufacturer accordingly as per Clause 7.4 of EN 3-7:2004+A1:2007-08 standards as per the accredited test report for backpack system.8.Fire Rating: 55A, 233B, 1000V with Special AFFF Compound as per manufacturer own specifications with commercial brand name of fire extinguishing medium as per accredited laboratory test report for Backpack SystemCERTIFICATION 1.PED approval as per Directive 97/23/EC should be available.2.Pressure Vessel shall include a pressure gauge fitted on the Pressure Reducer (CE Marked from notified body) to measure the air cylinder pressure.3."No objection certificate (NOC) for Pressure Vessel from Petroleum and Explosives Safety Organization (PESO) Nagpur "should be submitted.4.Pressure Vessel should have CE Marking from Notified body5.The air cylinders shall have PESO, Nagpur approval to be used with Water Mist Fire Fighting System6.Specific consent of the OEM for the value additions made along with a confirmation that fire ratings of the equipment would not be affected by these value additions.7.Test Report to EN Standard as per above serial number 1 of Generic should be submitted.
106OD71842/2023-2024:Payment to KSEB Ltd. for three phase power connection
Disclaimer :
We takes all possible care for accurate & authentic tender information, however Users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender.
Tell us about your Product / Services,
We will Find Tenders for you

Copyright © 2024 · All Rights Reserved. Terms of Usage | Privacy Policy

For Tender Information Services Visit : TenderDetail