Tender For Comprehensive Maint Of Dg Sets, Amf Panels And Repair Replacement Of Unsv Streets Light, Perimeter Light, Timer Panels, Pole Box And High Mast Led Flood Light, Street Light, Fascad Light Drivers And New Opd At Bhdc Under Ge (East) Delhi Ca, delhi-Delhi

Military Engineer Services-MES has published Tender For Comprehensive Maint Of Dg Sets, Amf Panels And Repair Replacement Of Unsv Streets Light, Perimeter Light, Timer Panels, Pole Box And High Mast Led Flood Light, Street Light, Fascad Light Drivers And New Opd At Bhdc Under Ge (East) Delhi Ca. Submission Date for this Tender is 12-08-2023. Halogen Light Tenders in delhi Delhi. Bidders can get complete Tender details and download the document.




Tender Notice

38778213
Tender For Comprehensive Maint Of Dg Sets, Amf Panels And Repair Replacement Of Unsv Streets Light, Perimeter Light, Timer Panels, Pole Box And High Mast Led Flood Light, Street Light, Fascad Light Drivers And New Opd At Bhdc Under Ge (East) Delhi Ca
Open Tender
Indian
Delhi
delhi
12-08-2023

Tender Details

Comprehensive Maint Of Dg Sets, Amf Panels And Repair Replacement Of Unsv Streets Light, Perimeter Light, Timer Panels, Pole Box And High Mast Led Flood Light, Street Light, Fascad Light Drivers And New Opd At Bhdc Under Ge (East) Delhi Cantt-10

Key Value

Document Fees
INR 500 /-
EMD
INR 97540.0 /-
Tender Value
INR 48.77 Lakhs /-

BOQ Items

Name of Work: COMPREHENSIVE MAINT OF DG SETS, AMF PANELS AND REPAIR REPLACEMENT OF UNSV STREETS LIGHT, PERIMETER LIGHT, TIMER PANELS, POLE BOX AND HIGH MAST LED FLOOD LIGHT, STREET LIGHT, FASCAD LIGHT DRIVERS AND NEW OPD AT BHDC UNDER GE (EAST) DELHI CANTT-10
Sl. No. Item Description
1Comprehensive maintenance and repair 320 KVA DG Set with AMF Trauma Centre including replacement of defective parts/ fitting inclunding all required electrical and mechanical Spares required for comprehensive maintenance during the entire contract period of utility press. Make- Greaves
2Comprehensive maintenance and repair 320 KVA DG Set with AMF Main Power House including replacement of defective parts/ fitting inclunding all required electrical and mechanical Spares required for comprehensive maintenance during the entire contract period of utility press. Make- Greaves
3Comprehensive maintenance and repair 200 KVA DG Set with AMF Main ICU including replacement of defective parts/ fitting inclunding all required electrical and mechanical Spares required for comprehensive maintenance during the entire contract period of utility press. Make- Cummins
4Comprehensive maintenance and repair 63 KVA DG Set with AMF Old Base including replacement of defective parts/ fitting inclunding all required electrical and mechanical Spares required for comprehensive maintenance during the entire contract period of utility press. Make- Kirlosker
5Comprehensive maintenance and repair 40 KVA DG Set with AMF Power House including replacement of defective parts/ fitting inclunding all required electrical and mechanical Spares required for comprehensive maintenance during the entire contract period of utility press. Make- Kirlosker
6Comprehensive maintenance and repair 110 KVA DG Set with AMF Dental Dept including replacement of defective parts/ fitting inclunding all required electrical and mechanical Spares required for comprehensive maintenance during the entire contract period of utility press. Make- Cummins
7Repair, preventive and periodical maintenance, testing and commissioningof DG Set 500/ 400 KVAMake : Greaves installed at OT Substation & COVID ICU Substation in Base Hospital including servicing and replacement of unserviceable parts etc complete all as specified and as directed. Notes:(i) Spare parts shall be measured and paid separately as "Supply only" under respective item of this Schedule. (ii)Coolant and Lub oil shallbe measured and paid separately under relevant item of this schedule.
8Supply only in replacement following Spare parts ofDG Set 500/ 400KVAMake : Greaves installed at X ray Substation in Base Hospital complete all as specified and as directed:-
9Filter Element With O ring
10Filter INSRT with O ring
11Element Air filter
12L.O Filter, Element V8/V6
13Repair, preventive and periodical maintenance, testing and commissioningof DG Set 320KVAMake : Greaves installed at X ray Substation in Base Hospital including servicing and replacement of unserviceable parts etc complete all as specified and as directed. Notes:(i) Spare parts shall be measured and paid separately as "Supply only" under respective item of this Schedule. (ii)Coolant and Lub oil shallbe measured and paid separately under relevant item of this schedule.
14Supply only in replacement following Spare parts ofDG Set 320KVAMake : Greaves installed at X ray Substation in Base Hospital complete all as specified and as directed:-
15Flt Element with O ring
16Flt INSRT with O Ring
17L.O Filter, Element V8/V6
18Element Air Filter
19Repair, preventive and periodical maintenance, testing and commissioningof DG Set 160 KVAMake : Cotton Greaves installed at X-Ray Sub Stn, Main Lab, Truma Substation,Cath Lab (100 KVA), Psychiatric ward, Psycatric Ward Oxygen Plantin Base Hospital including servicing and replacement of unserviceable parts etc complete all as specified and as directed. Notes:(i) Spare parts shall be measured and paid separately as "Supply only" under respective item of this Schedule. (ii)Coolant and Lub oil shallbe measured and paid separately under relevant item of this schedule.
20Supply only in replacement following Spare parts ofDG Set 160 KVAMake : Cotton Greaves installed atX-Ray Sub Stn, Main Lab, Truma Substation,Cath Lab (100 KVA), Psychiatric ward, Psycatric Ward Oxygen Plantin Base Hospitalcomplete all as specified and as directed:-
21Kit fuel filter and rings Cat Part No
22Air Filter
23Lub oil filter
24Repair, preventive and periodical maintenance, testing and commissioningofDG Set 200KVAMake : Cotton Greaves installed at GE Centre,Surgical-III, Ortho I&II in Base Hospital including servicing and replacement of unserviceable parts etc complete all as specified and as directed. Notes:(i) Spare parts shall be measured and paid separately as "Supply only" under respective item of this Schedule. (ii)Coolant and Lub oil shallbe measured and paid separately under relevant item of this schedule.
25Supply only in replacement following Spare parts of DG Set 200KVAMake : Cotton Greaves installed at GE Centre,Surgical Substation , Ortho I&II,in Base Hospitalcomplete all as specified and as directed:-
26Kit fuel filter and rings
27Air Filter
28Lub oil filter
29Repair, preventive and periodical maintenance, testing and commissioningofDG Set 62.5/50 KVAMake :Cotton Greaves installed at, ICU Substation, Mortuary, Dialysis, in Base Hospital including servicing and replacement of unserviceable parts etc complete all as specified and as directed. Notes:(i) Spare parts shall be measured and paid separately as "Supply only" under respective item of this Schedule. (ii)Coolant and Lub oil shallbe measured and paid separately under relevant item of this schedule.
30Supply only in replacement following Spare parts of DG Set 62.5 KVAMake :Cotton Greaves installed at Main Power House, ICU Substation, Mortuary in Base Hospital complete all as specified and as directed:-
31Kit fuel filter and rings
32L.O Filter, Element V8/V6
33Air Filter Primary
34Air Filter safety 8"
35Lub oil filter 8" (Note:Item Nos 1.00 to 16.05 shall be executed by the Authorised service dealer of OEM.Dealer Name- Airmen Engineers & Services Pvt Ltd (Rohini Delhi)/SSM Diesel (Janakpuri Delhi)/Ambika Power Point (Gaziabad, U.P))
36Supply only inhibitor corrosion (Coolant) green/red suitable for DG Sets 40 KVA to 320 KVAcapacity, of make Cummins, Kirloskar and Crompton Greaves completeall as specified and as directed.
37Supply only Lub oil 20W/40 multigrade, suitable for DG Sets 40 KVA to 320 KVAcapacity, of make Cummins, Kirloskar and Crompton Greaves completeall as specified and as directed.
38S&F in replacement fuse base suitable for cylindrical/DIN type HRC/HBC fuse link type 630/400 A for AMF panel for DG Sets of following capacities complete all as specified and as directed:-
39DG Set 500/320/310 KVA
40DG Set 160/166/200 KVA
41DG Set 40 KVA
42S&F in replacement power contactor series MNX/MCX -3 pole, AC control suitable for AMF panel of DG Sets of following capacity complete all as specified and as directed:-
43MNX -40
44MNX-45
45MNX -250
46MNX -650
47S& F in repairset of Copper lead (Wire) 2.50 metre long with clamp for 12Volts 180 AHBatteries complete all as specified and as directed.
48S&F in repair Lead Acid Battery 12Volts, 180AH suitable for DG set complete all as specified and as directed.
49Cleaning of fuel tank made out of MS sheet of capacity up to 320 KVA DG Set of 500/1000 litre capacity approx by draining out fuel in a separate container, taking out all silt/ dirt, deposition inside the tank, cleaning it completely by manual labour and necessary T&P and refitting and connecting with fuel pipes with DG sets all as per site requirementcomplete all as specified and as directed.
50M&L for servicing and setting of AMF panel of DG Set including replacement of complete wiring, Phase Preventer, Panel Indicator, Battery Charger, Selector Switch, Voltmeter & Ammeter, Engine Starting Relay, Under Voltage Relay & On Delay Timer complete all as specified and as directed.
51Supply only in replacement single Phase Preventer as per sample complete all as specified and as directed.Model: VSP-2 Make- Minilec/ L&T
52Supply only in replacement Engine Starting Relay as per sample at site complete all as specified and as directed.
53Supply only in replacement selector switch as per sample at site complete all as specified and as directed.
54Supply only in replacement On-Delay timer of 230 VAC, Range: 0 to 60 sec. complete all as specified and as directed.
55Supply only in replacement Under Voltage relay as per sample at site complete all as specified and as directed.
56Supply only in replacement single core copper conductor PVC insulated unsheathed240 V grade, flexible, 4 Sqmm complete all as specified and as directed.
57All as per ser Item No 30.00 here in before but 6 Sqmm complete all as specified and as directed.
58Supply and topping Distilled Water for DG Set battery complete all as specified and as directed.
59Excavation in trenches not exc 1.5 m wide and not exc 1.5 m in depthfor foundation/ fixing pole/ laying cable and pipe line etc or for man hole etc not exc 10 Sqm on plan and getting out in soft / loose soil complete all as specified and as directed.
60Returning filling in including spreading, levelling, watering and well ramming in layers, not exceeding 25 cm thick using excavated soil complete all as specified and as directed.
61Removing excavated Soil to a distance not exceeding 50 metre and depositing where directed at a level not exceeding 1.5 metre above the starting point complete all as specified and as directed.
62M&L for providing dry river sand as in sand cushioning to under ground electric cable including punning down of sand in layer complete all as specified and as directed. Note:For measurement & payment purpose, punned thickness of sand only shall be considered.
63Supply and Laying in replacement burn brick, sub class "B", old size for cable coveringcomplete all as specified and as directed.
64Supply, laying, connecting, testing and commissioning in replacement, LT cable XLPE insulated, screened,PVC inner sheathed, armoured with galvanised steelstrip or wire, electric power cable, heavy duty with stranded aluminium conductor 1100 Volt grade, laid in trenches / duct, passing through pipe / duct or fixed on pole, of size 10 Sqmm, 2 core including taking out old cable complete all as specified and as directed.
65All as per item No 38.00 here in before but cable of size 16 Sqmm, 2 core complete all as specified and as directed.
66All as per item No 38.00 here in before but cable of size 25 Sqmm, 4 core complete all as specified and as directed.
67Supply, laying, connecting and testing in repair95 Sqmm, 3.5core, XLPE insulated, PVC inner sheathed, armoured with galvanised steelstrip or wire, heavy duty, LT underground cable, with aluminium multistranded conductor, 1100 Volt grade, laid in trenches / duct, passing through pipe / duct or fixed on pole including taking down old cable complete all as specified & as directed.
68Supply, laying, connecting and testing in repair70 Sqmm, 3.5core, XLPE insulated, PVC inner sheathed, armoured with galvanised steelstrip or wire, heavy duty, LT underground cable, with aluminium multistranded conductor, 1100 Volt grade, laid in trenches / duct, passing through pipe / duct or fixed on pole including taking down old cable complete all as specified & as directed.
69Supply, laying, connecting and testing in repair50 Sqmm, 3.5core, XLPE insulated, PVC inner sheathed, armoured with galvanised steelstrip or wire, heavy duty, LT underground cable, with aluminium multistranded conductor, 1100 Volt grade, laid in trenches / duct, passing through pipe / duct or fixed on pole including taking down old cable complete all as specified & as directed.
70Supply, fixing and connecting in repair 90W New generation energy saving and environment friendly long life LED street light made up of pressure die cast aluminium housing alloy for effective thermal management, sturdiness, excellent corrosion resistant with high power LED as lighting source and lens embedded PC/ toughened glass cover with IP66 protection and impact resistance of IK07, minimum Lumen output of fixture 9900lumens with minimum efficacy of 110lm/W, CRI>70, THD<10%, PF>.95, CCT- 5700K, 4KV surge protection complete all as specified and as directed.
71Supply, fixing and connecting in repair 120W New generation energy saving and environment friendly long life LED street light made up of pressure die cast aluminium housing alloy for effective thermal management, sturdiness, excellent corrosion resistant with high power LED as lighting source and lens embedded PC/ toughened glass cover with IP66 protection and impact resistance of IK07, minimum Lumen output of fixture 13200 lumens with minimum efficacy of 110lm/W, CRI>70, THD<10%, PF>0.95, CCT- 5700K, 4KV surge protection complete all as specified and as directed.
72supply, installation, testing and commissioning in repair factory made CPRI approved, outdoor type, wall mounted LT panel Board confirming to IS 8623 with IP-54 protection made out of 3.15mm thick CRCA sheet 415 V, 3P, 50 Hz with front openable double door with provision of locking arrangement, dust & vermin proof, gasket, TPN Bus bar duly insulated with colour coated heat shrinkable sleeves and mounted on proper insulator gland welding hinges of dust proof, overall powder coated, suitable for andconsisting of the following equipments & Accessories, including dismantling of old panelcomplete all as specified and as directed: - (a) MCCB TP, 415V, 100 Amp, 35 KA - 01 No (b) Power Contractor, 3 Pole, 73 Amp - 01 No Make BCH Cat No CE15KN3 or equivalent model of Make Schneider/Siemens/L&T or any other make mentioned in PS (c) Auto/Manual switch - 01 No (d)R-Y-B indicator Lamp, (e) Timer Switch Clock Type
73Supply, Installation, testing and commissioning PVC, weather proof KIOSK box, size 333 x 233 x 120 mm (outside) and minimum 1.5 mm wall thickness, made out of one piece mounted SMC base and door pole mounted hinged door,comprising of aluminium bus bar 4 strips for 3 phase and neutral 63 Amp including 06 Amp MCB, SP,for controlling the street light fitting including PVC sheathed copper stranded conductor cable, 1.5 Sqmm, two run, from street light fitting to KIOSK box and mild steel flat iron clamps 30x 4 mm with necessary MS nuts bolts and washers including embossing/ painting of Danger notice of size not less than 10 cm x 7.5cm with letters, figures and conventional skull and bones in signal red colour on front face of KIOSK box body complete all as specified and as directed.Make Sintex Cat part No GS JB 3020 or equivalent model of Make- FINOLEX/ UNIVERSAL Switchgear
74M&Lin repair PVC insulated, multistranded copper cable,three core, 2.5 Sqmm,1100 volts grade, drawn in existing conduit/ Casing Capping complete all as specified and as directed.
75Supply, jointing and testing straight through, heat shrinkable, jointing kit suitable for PVC/ XLPE insulated armoured heavy duty aluminium conductor 1100 volt grade of size 10/16 Sqmm, 4 core including taking out faulty portion of cable in any situation/ position complete all as specified and as directed.
76All as per srl item No 49.00 here in before but for cable of size 25/35 Sqmm, 3.5 core complete all as specified and as directed.
77All as per srl item No 49.00 but for cable of size 50/70 Sqmm, 3.5 core complete all as specified and as directed.
78All as per srl item No 49.00 but for cable of size 95/120 Sqmm, 3.5 core complete all as specified and as directed.
79M&L for locating the fault in underground electrical power cable of any length & any type of 1100 volt grade LT cables, by arranging fault locating Machine & pin point the fault, cutting the cable at fault to fixing the joint including testing of the cable after locating fault and jointing cable including excavation and earth work in any type of soil completeall as specified and as directed. Note:- (i) Jointing of cable shall be measured and paid separately under respective item of this Schedule. (ii) If fault is not rectified within 24 hours after receiving Message, the contractor shall be charged penalty for Rs 500/- per hour per complaint and shall be deducted from next payment due to contractor.
80M&L for painting on steel tubular Pole (of any height) for street light fittings including GI pipe/brackets fixed on poles, by applying two coats of synthetic enamel paint of aluminium colour including cleaning & preparingthe surface properly with sand paper including making strip with yellow/black/ white colour synthetic enamel paint (road signal paint) of the required width as directed at site up to 1.5 metre height from ground level, writing numbers and letters of required size as directed at site above 1.5 metre height from ground level complete all as specified and as directed. Note:Quoted Rate shall deemed to be Inclusive of Painting numbering of Poles after Painting work.
81M&L for painting on PCC Pole (of any height) for street light fittings including GI pipe/brackets fixed on poles, by applying two coats of water Bonding cement based paint, Grey colour, including cleaning and preparation of surface properly with sand paper, making strip with yellow/black/ white colour synthetic enamel paint (road signal paint) of the required width as directed at site up to 1.5 metre height from ground level, writing numbers and letters of required size as directed at site above 1.5 metre height from ground level complete all as specified and as directed. Note:Quoted Rate shall deemed to be Inclusive of painting numbering of Poles after Painting work.
82S&F in replacement timer electronic type 415 Volt, 50HZ, one dial daily, complete all as specified and as directed.
83Cutting/trimming of tree branches around street light fitting up to 5 metre distance at all sides and disposal of debris out side MOD land complete all as specified and as directed.
84M&L excavation in trenches for tracing out the faults in any size of LT underground cable, in any type of soil i.e. Soft/loose/hard/dense soil, taking out the faulty portion of cable for jointing, jointing cables, refilling the excavatedtrenches with excavated material, disposal of surplus soils outside MOD land and making the disturbedsurfaces to match with the surrounding area complete all as specified and as directed.
85Taking out street light pole any type/sizeand shifting to another place and other similar situation, re-connecting the electrical connection in the same/new position including PCC and coping work of pole Complete all as specified and as directed.
86Supply, fixing and connecting in repair40 Watt, decorative post top Lantern, for 360 degree indirect light, with IP 65 Protection, resistant to impact and corrosion, Glare free and better uniformity including taking out old unserviceable post Top lanternsComplete all as specified and as directed.Make CG Cat No LPTO-40-CDL/M or equivalent Model of Make mentioned in PS.
87S&F LED Street Light fitting 25 watt, system efficiency not less than 100 lumen / watt, IP65 protection,consisting of high / low voltage cut off, maintenance free isolated Electronic driver circuits, Low THD, PMMA grade high quality Transmittance lens, Epoxy powder coated Die Cast Aluminium housing with weather proof gasket for lamp & driver compartment, Heat resistance toughened glass fitted in cast aluminium housing with SS screws,fixed on existing bracket & connecting including taking down old light fitting of any description complete. Make :- CG ,Philips, Wipro, Havell"s, halonix, Polycab
88S&F LED Street Light fitting 45 watt, system efficiency not less than 100 lumen / watt, IP65 protection,consisting of high / low voltage cut off, maintenance free isolated Electronic driver circuits, Low THD, PMMA grade high quality Transmittance lens, Epoxy powder coated Die Cast Aluminium housing with weather proof gasket for lamp & driver compartment, Heat resistance toughened glass fitted in cast aluminium housing with SS screws,fixed on existing bracket & connecting including taking down old light fitting of any description complete. Make :- CG ,Philips, Wipro, Havell"s, halonix, Polycab
89S&F in replacementBollard light fitting 10 watt LED type Integral decorative LED chip & driver, opal acrylic with IP-65 protection including all accessories, fixing arrangement internally pre-wired,fixedin position complete with excavation, post hole of size 300 mm x 300 mm x 300 mm deep & filling the same with PCC 1:3:6 and grouting the bolts for fixing light fitting & connectingcomplete all as specified and directed by Engg –in-charge. Make:- Crompton make mention in Wipro, Philips, Havell"s, halonix
90S&F LED FLOOD Light fitting 180 watt, system efficiency not less than 100 lumen / watt, IP65 protection,consisting of high / low voltage cut off, maintenance free isolated Electronic driver circuits, Low THD, PMMA grade high quality Transmittance lens, Epoxy powder coated Die Cast Aluminium housing with weather proof gasket for lamp & driver compartment, Heat resistance toughened glass fitted in cast aluminium housing with SS screws fixed on existing bracket & connecting, including taking down old light fitting of any description complete.Make :- CG ,Philips, Wipro, Havell"s, halonix, Polycab
91S&F LED FLOOD Light fitting 240/250 watt, system efficiency not less than 100 lumen / watt, IP65 protection,consisting of high / low voltage cut off, maintenance free isolated Electronic driver circuits, Low THD, PMMA grade high quality Transmittance lens, Epoxy powder coated Die Cast Aluminium housing with weather proof gasket for lamp & driver compartment, Heat resistance toughened glass fitted in cast aluminium housing with SS screws fixed on existing bracket & connecting, including taking down old light fitting of any description complete. Make :- CG ,Philips, Wipro, Havell"s, halonix, Polycab
92S&F LED FLOOD Light fitting 300 watt, system efficiency not less than 100 lumen / watt, IP65 protection,consisting of high / low voltage cut off, maintenance free isolated Electronic driver circuits, Low THD, PMMA grade high quality Transmittance lens, Epoxy powder coated Die Cast Aluminium housing with weather proof gasket for lamp & driver compartment, Heat resistance toughened glass fitted in cast aluminium housing with SS screws fixed on existing bracket & connecting, including taking down old light fitting of any description complete. Make :- CG ,Philips, Wipro, Havell"s, halonix, Polycab
93Supply and fix in repairs weather proof twin core PVC Insulated, PVC sheathed cable,1100 V grade, copper multistrandard conductor of size 2.5 Sqmm, as in service wire conductorfor looping box, O/H line to street light fittings complete including testing commission all as directed
94Supply and fix in repairs brackets of light grade GI pipe of 40 mm dia bore and 1200 mm long with a bend of 120 degree suitable for street light fittings with 2 sets of clamps of mild steel flat 30 mm x 6 mm suitable for RCC pole with nuts, bolts and washers complete all as directed.
Disclaimer :
We takes all possible care for accurate & authentic tender information, however Users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender.
Tell us about your Product / Services,
We will Find Tenders for you

Copyright © 2024 · All Rights Reserved. Terms of Usage | Privacy Policy

For Tender Information Services Visit : TenderDetail