Jharkhand Industrial Infrastructure Development Corporation Limited has published Tender For Development Of Modular Operation Theater At Sadar Hospital Ramgarh Jharkhnad. Submission Date for this Tender is 28-07-2023. Modular Operation Theater Tenders in ramgarh Jharkhand. Bidders can get complete Tender details and download the document.




Tender Notice

38770619
Tender For Development Of Modular Operation Theater At Sadar Hospital Ramgarh Jharkhnad
Open Tender
Indian
Jharkhand
ramgarh
28-07-2023

Tender Details

Development Of Modular Operation Theater At Sadar Hospital Ramgarh Jharkhnad

Key Value

Document Fees
INR 11800 /-
EMD
INR 458000.0 /-
Tender Value
INR 4.57 Crore /-

BOQ Items

Name of Work: Development of Modular Operation Theatre at Sadar Hospital, Ramgarh, Jharkhand
Sl. No. Item Description
1•Standard wall partitions in Operation Theatre are composite construction of two skins of PPGI/PPGI with a panel thickness of 50 mm, over a GI framework with a sealed and insulated interior. The standard panel has of dimensions 1000mm x 2425mm. Standard panels are an overall thickness 50 mm. The self-supporting internal walls are constructed with an interior GI framework. Partition-to-partition connections are maintained with precision with GI profiles that create uniform seams.The partition seams are sealed by silicone with a perfectly flush finish. PUF insulation material is sandwiched between two skin layers and sealed from the exterior by a GI framework. Self-supporting wall provide in modular units consisting of external skins (exposed to room) in PPGI, outer (skin not exposed into the room) PPGI, which will be 0.6mm thick, with a protective film to prevent surface damage during shipping and installation. The movable wall includes the following: a) PUF insulation - 40 Kg/Cum (High pressure) b) GI profile c) Silicone sealant (clear, white) d) Sheet thickness 0.6 for PPGI
2After erection of GFRG wall panels, seal all GFRG wall joints with paper tape temporarily. Water proofing treatment of vertical joints with Zycosil/equivalent water proofing Solution (1 litre of Zycosil/equivalent & 20 litres of water stirred first & 2 litres of Zycoprime/equivalent added and stirred (total 23 litres)) with 50 ml syringe till the gap and in filled concrete is completely saturated. After removing the paper seal, seal off the vertical joints with water proofing material "Grout RW/equivalent " (Sealing cost excluded.)
3• Ceiling panels are designed to fit within each other and suspended by threaded tension bars with adjustable turnbuckles fastened to the overhead support at fixed intervals, Standard Ceiling Panels are 50 mm thick, walkable type, and have a composite construction of two skins of PPGI/PPGI, over a GI framework with a sealed and insulated interior. The ceiling includes the following: a) PUF insulation - 40 Kg/Cum (High Pressure) b) GI. c) Silicone sealant (clear & white).
4• One main advantage of vinyl floors is that they are durable. Vinyl flooring can last for a very long time with minimum maintenance. This flooring is highly recommended for Operation Rooms as it can withstand high levels of foot traffic and is resistant to stains. Operation Theatre flooring will be 2mm thick with covings, with welded joints with the following specifications: a. Flooring in each operating room will be seamless with perfectly curved flash-covings. b. It shall have anti-bacterial and fungicidal properties. c. Flooring is a static-conductive, flexible homogeneous vinyl floor.
5• Hermetically sealed sliding doors are specially designed to control the clean air pressure in the room which is of utmost importance at a Hospital. The door is developed especially for operation theatres and sterile areas. Normally an operation theatre runs under pressure. At this pressure and leakage losses will still not be measurable due to the hermetic sealing property of the door. • Hermetically sealed Manual in ICU/OT with the size 1500 mm*2100 mm for fixing on the wall with the following specifications: a) Door Blade: Door core of 50-60mm thick built up with HPL sheet as the skin at both sides of the door to provide better strength CFC-free, high-density polyurethane puff (density 40 kg/m^3), thickness. b) Door Profile: The door core is surrounded by 2.5mm thick high-grade aluminium extrusion profiles with natural anodizing of 15 microns finish. The aerodynamic design of profiles shall make the door ROBUST in its segment league. c) Gaskets: The door blade is made with a 3-tier specially designed 3 side’s heavy duty replaceable EPDM gasket against the wall frame. Bottom sealing with 2-tier heavy-duty EPDM gasket to flush with the finished floor. d) Window: High-quality double-glazed flush vision window of 300mmx300mm view size on both sides flush with the door blade. e) Wall Frame: High-grade Al extrusion with natural anodized 15-micron finish wall frame profile. This wall frame profile is 3 sided blind fixed with cladding on the wall cut-out section from inside & outside of the room. f) Operation: Door opening/Closing options Manual.
6• Laminar flow is defined as airflow in which the entire body of air within a designated space is uniform in both velocity and direction. • Specialized Air Distribution based on Total Pressure Displacement so as to ensure Uniform air quality & quantity along the complete Laminar Airflow (LAF) area. Minimum total air changes are maintained by more than 30 per hour. It is a terminal filter (HEPA filter is fitted across total filtration area i.e. 8 sq. ft & 24sq.ft = 2 Nos.), Ultra Clean ventilation system with unidirectional flow. It is a draft-free, comfortable room climate, and minimal, undisruptive noise level. It has a filtration area of at least 600 mm X 300 mm and (1220X1830mm) = 2 NOS and capable of filtering 4500 cfm of air. It has minimal pathogen concentration < 10 c.fu./Cum. Specifications are as follows: a) Plenum Body - Filter housing and pressure chamber made out of high-end stainless steel 304 medical grade steel with matt polish sheet thickness 1.2mm specially designed to deliver uniform velocity across the entire HEPA plenum to maintain uniform linearity of air-01 No. Plenum fitted with SS grill with perforation. b) Return air risers of stainless steel 0.8mm thick with matt polish with aluminum polished/powder coated grill from where the return air shall be picked up. Return air grills in the main sterile zones are located such as to avoid dead air pockets. They are placed at the level of approx. 8 inches above the floor level.UV lamps are placed inside the risers. The quantity for each OT is 4 pieces with 9mm insulation antibacterial foam. c) Fresh air positive pressure consisting a of 5-micron washable filter EU4 grade & made of HDPE non-woven material. The fresh air component of the air change is required to be a minimum of 12-15 air changes/hour. d) Mini plate (H 14) HEPA, low-pressure drop filter to remove practices sizing up to 0.3 microns with 99.97% particle removing efficiency. e) 2 Air Handling Unit Capacity 4500 cfm. f) The Air Handling unit has electrical safety and has EN-1886 Certification for mechanical strength. The air handling in its double skin construction, internal coving design, and thermal break panel’s draw-throw type consisting of various sections, filter section fan section, coil section, and mixing box. Flexible canvas connection will be provided between fan outlets and panels, to avoid fan vibration to the body of AHU. The fan motor is energy efficient and shall 415 volts, 50 cycles, 3 phase totally enclosed fan cooled class F with IP 55 protection motor, drives FBE provided with belt drive arrangements. g) The coil is designed with inter-winding circuits to suit the DX system. The coil is in 2 sets with 6 rows in each set. h) Dampers are opposed to blade type. They are made of a double-skinned aero foil aluminum section with an internal gasket and assembled within a rigid extruded alloy frame. i) Fine filter and miscellaneous accessories are Microvee filters (2 pieces) with 98% efficiency down to 5 microns 610x610x305 mm and GI "B" class drain piping with insulation. Fresh air arrangement with louvers, bird screen & damper. j) Surgeons control panel & AHU control panel are membrane-type control panels, comprising-Complete of the following features. I. Day Time Clock – 1 No. II. Time Lapse Clock – 1 No. III. AHU, AC, Peripheral light controls – 1 No. IV. Lighting control. k. AHU control panel is with VFD (Variable Frequency Drive) IP 20 with provision for Hand on/Bypass Mode for appropriate blower fan motor, mains failure relays, electrical distribution equipment, and circuit protection equipment for all circuits within the operation theatre. All internal wiring is terminated in connectors with screw and clamps spring connections of the Clip-on type mounted, on a DIN rail and labeled with indelible proprietary labels. Individual fuses or miniature circuit breakers protect all internal circuits. l. Integration of 1 AHU with the outdoor unit is 5.5 Tr with proper copper piping, expansion valve & dryer filter. m. Integration of AHU with Outdoor unit with Expansion valve, dryer filter, side glass, Proper copper tubing, etc.
7• Ducting is an approach to air management that uses a series of metal or plastic pipes to carry heated or cooled air from one place to another. A duct system is often referred to as ductwork. • Duct in Modular Operation Theatre is made by assembling and erecting GI sheet with flange rectangular/square of "L" shaped hollow profile which includes all accessories such as carriage bolt, Gasket & appropriate sealant on longitudinal joints, etc. complete set of 24 gauge.
8• UV rays are very effective in killing a large number of pathogenic organisms of bacterial, viral, and fungi commonly seen in operating theaters such as pseudomonas, Clostridium difficile, MRSA, and VRE
9• Fumigation in Operation Theatre is a process of gaseous sterilization that is used for the killing of micro-organisms and prevention of microbial growth in the air, the surface of the wall, or the floor. • De-fumigation control panel is installed outside the operation theatre to monitor the room pressure and to start the de-fumigation system from outside the operation theatre. It will de-fumigate the theatre in a given time and will switch-On the AHU to increase operation theatre pressure without operating the Surgeon control panel
10• Medical Services Pendants, also known as Booms, are one of the most important pieces of equipment within the operation theatre, which ensure efficient use of space to provide staff with a method of transporting required medical services to the patient quickly and effectively. • Traditionally, staff has been required to run hoses and cables across the floor to power the tools they use each day in the pursuit of improved patient outcomes. This approach creates many issues, including trip hazards for staff, decreased theatre usability from unintended "no-walk" zones, and the need to install equipment on mobile trolleys which require storage outside of the theatre after each procedure. • Medical Services Pendants address all of these issues by relocating the necessary electrical, gas, audio-visual, and data services from their usual wall panel to thependant carrier unit, which can be moved around the theatre and positioned in close proximity to the surgeon, anesthetist, and patient. • This carrier is suspended from the ceiling via one or two rotating arms allowing the required services to be brought right to the area of work. This allows for maximum configurations of the operating theatre and provides the staff unhindered access around the room, without the risk of injury to themselves or others.
11• The X-Ray viewing screen is a device, which is placed behind a transparent screen to view the developed x-rays. These are specifically designed to offer backlighting for a radiographic picture. These devices are also used in Operation theatres, as they aid them greatly in seeing the developed x-rays with enough detail.
12• The magnetic writing board usually in the size of 2 X 3 feet for operating rooms is used for writing down information by doctors/surgeons. The information might be the list of instruments/implants or how the operation needs to be performed. The magnetic writing board is flushed into the Cleanroom wall.
13• Peripheral light provides overall room illumination and is designed to create a consistent light level across the space, irrespective of any special lighting required in specific locations. • A specially designed Peripheral Light for Operation theatre with dimensions of 585 X 585m.m. and 36 Watt with LED life of minimum 50,000 Hours and Lumen of 3000 Lux to be installed in the ceiling.
14Electric C-Arm Compatible Multipurpose OT Table • Length of Table:1900 m • Width of Table Top: 520 mm • Minimum Height (Without Mattress) : Min. 750mm • Maximum Height (Without Mattress): Max. 1000mm • Trendelenburg:25° • Reverse Trendelenburg: 25° • Lateral Tilt: ±20’ • Back Section: ±70° • Head Section : ±60° • Leg Section: 0°-90° • Floor Locking System: Center Floor Locking
15• Color: Silver • Finishing: Powder Coated • Material: Stainless Steel • Adjustable & Portable
16• Intensity: 1,80,000 + 1,80,000 Lux • Shadow less Feature: Yes • Numbers of LED"s: 48 + 48 • Intensity Control: 10~100 Digital Capacitive Feather Touch (Fully Remote Controlled) • Fitting Options Available: Ceiling 180 Degree, Ceiling 360 Degree, Mobile, Wall Mounted • Spot Diameter: 200-250 mm • Depth of Light Penetration: 150 mm • Color Temperature: 3800 – 4800 K • Color Rendering Index: 95 Ra • Focusing: Adjustable • LED Average life: >50000 Hrs. • Diameter of Light: 700 mm • Power Supply: 220V/50Hz AC • Power Consumption: 100 Watt • Optional Special Features: Battery Backup
17INSTRUMENT Trolley with two S.S Shelves, Frame made of stainless steel Mounted on five 7.5 cm. swivel castors. Wholly made of 304G stainless steel. Size: (30L x 18W X 32H) inch
18INSTRUMENT Trolley with two S.S Shelves, Frame made of stainless steel Mounted on five 7.5 cm. swivel castors. Wholly made of 304G stainless steel. Size: (38L x 20W X 32H) inch.
191. Four legs full SS. 2. HT: 18-39inch (Screw adjt.) SS top dia: 30cm.
20Full SS 304g with bowl.
21• Overall approx. step size:505mmL x 305mmW • First step height230mm and second step size 450 mm • Step made of full SS 304g
221. Overall Approx. Size: 37 Lx 19W x 60H inch. 2. S.S tubular frame. 3. Six removable plastic bins and two polystyrene lockable storage units with three drawers each. 4. Four swivel Castors, 150mm dia. (Two with Brakes.) 5. Complete with corner buffers, oxygen cylinder holders’ IV Rods’, cardiac massage board and electric lamp.
23• Conduits & bends • Switch boxes • Light boxes • Fan boxes • Junction boxes • Wires • Switches & Plates • MCBs
24• Peripheral light provides overall room illumination and is designed to create a consistent light level across the space, irrespective of any special lighting required in specific locations. A specially designed Peripheral Light for Operation theatre with dimensions of 585 X 585m.m. and 36 Watt with LED life of minimum 50,000 Hours and Lumen of 3000 Lux to be installed in the ceiling
25• Ophthalmic OT Table with three section for drainage system in the head section. The table should have sturdy base, column made of stainless steel, antibacterial and is easy to clean. Electromotive height and Trendelenburg positions with light weight hand held control unit. I. Length of Table - 1900 Mm II. Width of Table Top - 520 Mm III. Minimum Height (Without Mattress) - Min. 750 Mm IV. Maximum Height (Without Mattress) - Max.1000 Mm V. Trendelenburg- 25 Degree VI. Reverse Trendelenburg - 25 Degree VII. Leg Section - 0 - 90 Degree
26• Mayfield Attachment: 1. Stable, High Precision 3 point fixation of the head during surgery. 2. Suitable for Children and Adults. 3. Made up of SS 304 G. • Horse Shoe Attachment: 1. Made up of SS 304 G. 2. Horse shoe shaped section for positioning of head and desired level during surgery. 3. Stable and Comfortable. • Sujita Attachment: 1. 4 pin attachment. 2. Made up of SS 304 G. 3. Suitable for Children and adult. 4. Stable and comfortable
27• HV electrical components should be in the junction box. a) It Should be fully automatic and Foot Operated b) 24 VAC operated fascia. c) It should comply with LV requirement. d) The Bowl must be constructed in such a manner that it should eradicate back splash of water. e) Drainage should be precisely designed to avoid any overflowing. f) The sinks should have the capability to provide the convenience and it should also work on water saving concept. g) Material : Stainless Steel h) Color: Silver
28Air Conditioner
29Dustbin (Trio)
30GST@18%