Tender For Upgradation Of Existing Sports Facilities And Construction Of New Facilities At Jnp Township Phase - I, Raigad-Maharashtra

Jawaharlal Nehru Port Trust-JNPT has published Tender For Upgradation Of Existing Sports Facilities And Construction Of New Facilities At Jnp Township Phase - I. Submission Date for this Tender is 18-08-2023. Sports Complex Tenders in Raigad Maharashtra. Bidders can get complete Tender details and download the document.




Tender Notice

38763896
Corrigendum : Tender For Upgradation Of Existing Sports Facilities And Construction Of New Facilities At Jnp Township Phase - I
Open Tender
Indian
Maharashtra
Raigad
18-08-2023

Tender Details

Upgradation Of Existing Sports Facilities And Construction Of New Facilities At Jnp Township Phase - I

Corrigendum Details

Sr No CorrigendumDate Corrignedum CorrigendumType NewSubmissionDate
1 16-Aug-2023 Corrigendum_2 Date 18-08-2023

Key Value

Document Fees
INR 23600 /-
EMD
INR 3586000.0 /-
Tender Value
INR 15.19 Crore /-

BOQ Items

Name of Work:Upgradation of existing sports facilities and construction of new facilities at JNP Township (Phase - I).
Sl. No. Item Description
1PART A -PAVILION BUILDING & CRICKET GROUND
2CIVIL WORK
3EARTH WORKS
4Excavation for roadway in earth, soil of all sorts, sand gravel, or soft murum including dressing section to the required grade, camber and isde slopes and conveying the excavated materials with all lifts upto a lead of 50m and spreading for embackment or stacking as directed.
5Watering and compacting of embankment formed of materials obtained from the road cutting with in a lead of 50m,not less than 97% of standard Proctor density after laying them in layers of 20cm.to 30 cm. with Power roller.
6Filling in plinth and floors withapprovedexcavated material in 15cm. to 20cm. layers including watering and compacting etc. complete.
7Disposal of excavated excess earth/Ordinary rock away from the site including conveyance of materials up to an average lead of 5KM away from the site, and correspondiong required lift, loading, unloading etc complete as directed by the Engineer-in-charge. (The quantity is net quantity of capacity of truck after deduction of 20% for looseness)(considering the maximum disposal location at 5 KM distance)
8earth By mechanical transport including loading, unloading and stacking. (Lead upto 5KM away from the site)
9Providing dry rubble stone pitching 23cm (about 9") thick including all material, quarry spalls, labour etc. complete.
10TOTAL (EARTH WORK)
11CONCRETEWORKS
12Providing and laying Cast in situ/Ready Mix cement concrete in M-10 of trap/ granite/ quartzite/ gneiss metal for foundation and bedding including bailing out water, formwork, laying/pumping, compacting, roughening them if special finish is to be provided, finishing if required and curing complete, with fully automatic micro processor based PLC with SCADA enabled reversible Drum Type mixer/concrete Batch mix plant (Pan mixer) etc. complete.With natural sand/V.S.I. quality Artificial Sand
13Providing and laying Cast in situ/Ready Mixcement concrete in M15 of trap/ granite/quartzite/gneiss metal for steps including steel centering, plywood/steel formwork, laying/pumping, compacting, roughening them if special finish is to be provided, finishing uneven and honeycombed surface and curing etc. complete. The Cement Mortar 1:3 plaster is considered for rendering uneven and honeycombed surface, only. Newly laid concrete shall be covered by gunny bag, plastic, tarpaulin etc. (Wooden centering will not be allowed.),with fully automatic micro processor based PLC with SCADA enabled reversible Drum Type mixer/concrete Batch mix plant (Pan mixer) etc. complete. With natural sand/V.S.I. quality Artificial Sand
14Providing and laying Cast in situ/Ready Mix cement concrete M-25 of trap / granite /quartzite/ gneiss metal for R.C.C. work in foundations like raft, strip foundations, grillage and footings of R.C.C. columns and steel stanchions etc. including bailing out water, formwork ,cover blocks, laying/pumping, compaction and curing roughening the surface if special finish is to be provided (Excluding reinforcement and structural steel) etc. complete, with fully automatic micro processor based PLC with SCADA enabled reversible Drum Type mixer/ concrete Batch mix plant (Pan mixer) etc. complete. With fine aggregate (Natural Sand / Crushed sand VSI Grade finely washed etc)
15Providing and fixing in position TMT - FE - 500 bar reinforcement of various diameters for R.C.C. pile caps, footings, foundations, slabs, beams columns, canopies, staircase, newels, chajjas, lintels pardis, copings, fins, arches etc. as per detailed designs, drawings and schedules. including cutting, bending, hooking the bars, binding with wires or tack welding and supporting as required complete.
16TOTAL (CONCRETEWORKS)
17BRICK WORK
18Providing second class Burnt Brick masonry with conventional/ I.S. type bricks in cement mortar 1:6 in foundations and plinth of inner walls/ in plinth external walls including bailing out water manually , striking joints on unexposed faces, raking out joints on exposed faces and watering etc. Complete.
19Providing second class Burnt Brick masonry with conventional/ I.S. type bricks in cement mortar 1:4 in half brick thick wall including mild steel longitudinal reinforcement of 2 bars of 6 mm diameter / 2 hoop iron strips 25 mm X 1.6 mm placedat every third course, properly bent and bonded at ends scaffolding, racking out joints and watering etc. complete.
20TOTAL (BRICKWORKS)
21STEEL WORK
22Providing and fabricating structural steel work in rolled sections like joists, channels, angles, tees etc. as per detailed design and drawings or as directed including cutting, fabricating, hoisting, erecting, fixing in position making riveted / bolted /welded connections without connecting plates, braces etc. and including one coat of anticorrosive paint and over it two coats of oil painting of approved quality and shade etc. complete.
23Providing structural steel work in hollow section of various thickness and sizes in square, rectanular and round shape from 25mm to 450mmsection as per IS 4923 YST 310 Grade produced from iron ore and blast furnace route etc. as per detailed designs and drawing or as directed including cutting, fabricating, hoisting, erecting, fixing in position, making riveted/bolted/ welded connections and painting complete.
24TOTAL (STEEL WORK)
25FINISHING WORK
26Providing internal cement plaster 12mm thick in single coat in cement mortar 1:3 without neeru finish to concrete or brick surfaces, in all position including scaffolding and curing etc. complete.
27TOTAL (FINISHING WORK)
28ROAD WORK
29Providing and laying C.C. pavement of mix M-25 with ready mixed concrete from batching plant. The ready mixed concrete shall be laid and finished with screed board vibrator , vacuum dewatering process and finally finished by floating, brooming with wire brush etc. complete as per specifications and directions of Engineer-incharge. (The panel shuttering work shall be paid for separately).
30Providing and laying 125micron Low Density Polyethylene (LDPE) sheet confirming to IS 3395 : 1997 below concrete pavement including all materials and labour complete.
31Providing and laying 60mm thick faciory made cement concrete interlocking paver block of M -30 grade made by block making machine with strong vibratory compaction, of approved size, design & shape, laid in required colour and pattern over and including 50mm thick compacted bed of coarse sand, filling the joints with line sand etc. all complete as per the direction of Engineer-in-charge.
32Providing and fixing G.I. chain link fabric fencing of required width in mesh size 50x50 mm including strengthening with 2 mm dia wire or nuts, bolts and washers as required complete as per the direction of Engineer-incharge. Made of G.I. wire of dia 4 mm
33Providing and applying two coats of synthetic enamel paint of approved colour to new /old structural steel work and wood work in buildings, including scaffolding if necessary, cleaning and preparing the surface (excluding primer coat) etc. complete.
34Providing and fixing factory made precast RCC perforated drain covers, having concrete of strength not less than M-25, of size 1000 x 750x50 mm, reinforced with 8 mm dia four nos longitudinal & 9 nos cross sectional T.M.T. hoop bars, including providing 50 mm dia perforations @ 100 to 125 mm c/c, including providing edge binding with M.S. flats of size 50 mm x 1.6 mm complete, all as per direction of Engineerin- charge.
35TOTAL (ROAD WORK)
36TOTAL CIVIL WORK
37ELECTRICAL WORKS
38SUBHEAD- I:DISTRIBUTION BOARD
39Supplying and erecting single pole and neutral distribution board (SPNDB) with door surface/flush mounted with 2 ways for incoming and 10 ways for outgoing SP MCB’s on iron/ GI frame as per specification no. SW-SWR/MCBDB
40Supplying erecting and marking double pole isolator only switch version of miniature circuit breaker of 40A with required wiring
41Supplying, erecting & marking SPMCB 6A to 32A, C-series (for motor/power) in provided distribution board as per specification no. SW-SWR/MCB
42Providing, erecting and commissioning 2 pole RCCB only of electromagnetic type with 30/100/300 mA sensitivity and having capacity of 63A complete as per specification no. SWRCCB/ RCCB
43Total SUB HEAD -I
44SUB-HEAD - II: INTERNAL WIRING
45Point wiring for light/fan/bell hybrid type (Surface type under false ceiling and concealed type for drops & switch boards on walls) in min 20 mm PVC conduit / casing n capping with 1.5 sq.mm. (2+1E) FR grade copper wires, modular type switch,earthing and required accessories as per specification No: WGPW/ HW
46Secondary point wiring for additional light/ bell point, concealed type in min 20 mm PVC conduit with 1.5 sq.mm. (2+1E) FR/FRLSH grade copper wires with required accessories as per specification No: WG-PW/CW
47Supplying & erecting mains with 3x2.5 Sq.mm F.R copper PVC insulated wire laid in provided conduit/trunking/inside pole/Bus bars or any other places as per specification No: WGMA/ BW
48Supplying & erecting mains with 3x4 sq.mm FR copper PVC insulated wire laid in provided conduit/trunking/inside pole/Bus bars or any other places as per specification No: WGMA/ BW
49Supplying & erecting mains with 3x6 sq.mm F.R copper PVC insulated wire laid in provided conduit/trunking/inside pole/Bus bars or any other places as per specification No: WGMA/ BW
50Supplying & erecting mains with 3x10 sq.mm F.R copper PVC insulated wire laid in provided conduit/trunking/inside pole/Bus bars or any other places as per specification No: WGMA/ BW
51Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed steel conduit as required
52Supplying and erecting ISI mark modular type switch 6A / 10A duly erected on provided plate and box with wiring connections complete.
53Supplying and erecting ISI mark modular type 5 pin socket with safety shutters 3 module socket 6A 240V AC supply, duly erected on provided plate and box with wiring connections complete duly erected
54Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 6 pin 5/6 & 15/16 amps modular socket outlet and 15/16 amps modular switch, connection etc. as required.
55Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providng and fixing 2 nos. 3 pin 5/6 A modular socket outlet and 2 nos. 5/6 A modular switch, connections etc. as required. (For light plugs to be used in non residential buildings).
56Supplying & erecting original 1.25 mm CRCA sheet metal enclosures with 20A. 2 pin plug & earth socket and 20A. 3 pin plug top with 20A/30A single pole MCB complete erected on angle iron/ GI frame.
57Supplying and erecting electronic type step regulator for ceiling fan 600/ 900/ 1200/ 1400 mm. sweep, complete erected on provided switch board.
58Total SUB HEAD -II
59SUB-HEAD III - FANS & LIGHT FIXTURES:
60Supplying & erecting LED 20W tube light fitting (4 feet) with aluminium housing, heat sink, integrated HF electronic driver complete Approved make:- Polycab
61Supplying and erecting LED square / circular 13 to 15W down lighter having pressure die-cast aluminum housing, opal translucent cover, mounting arrangement with board for surface type or spring loaded mounting clips for flush type complete.Approved make:- Polycab
62Supplying and erecting LED square / circular 16 to 20W down lighter having pressure die-cast aluminium housing, opal translucent cover, mounting arrangement with board for surface type or spring loaded mounting clips for flush type complete.Approved make:- Polycab
63Supplying and erecting LED Mirror Light with integrated driver including 7W to 9W lamp with polycarbonate housing and opal diffuser to be fixed above mirror or as required on clamps complete.. Approved make:- Polycab
64Supplying and erecting regular/ standard model ceiling fan of 1400mm. sweep complete erected in position as per specification no. FG-FN/CF Approved make:- Polycab
65Supplying and erecting fresh air cum exhaust fan of light duty 250 V A.C. 50 cycles 300mm. 1400 RPM rust proof body & blades, wire mesh, duly erected in an approved manner.Approved make:- Polycab
66Supplying and erecting decorative oval bulk head edge-lit 10W LED luminaire comprising of high brightness LED Fitting on provided PVC block / wooden board. Approved make:- Polycab
67TOTAL SUB HEAD III
68SUB HEAD-IV : T.V. , TELEPHONE, DATA SYSTEM, CONDUITING andLAN SYSTEM
69Supplying & erecting telephone copper cable 2 pair with 0.5 mm dia. laid in provided PVC casing capping/ conduit as per specification No. WG-TW
70Providing, fixing connecting and testing of under noted size of solderless telephone tag block Krone make in surface/recess in wall required size of M.S. box with hinged lockable cover duly stove enamel painted.
715 pair tag block
72Supplying and erecting PVC trunking (PVC casing-ncapping)of size 20 mm with accessories on wall/ceiling as per specification No: WG-MA/CON.
73Supplying and erecting PVC trunking (PVC casing-ncapping)of size 32 mm with accessories on wall/ceiling as per specification No: WG-MA/CON.
74Supplying and erecting ISI mark GI pipe 75/80 mm dia. ‘B’ class at position with accessories complete. Specification no. CW-PLB/GP.
75Supplying and erecting ISI marked modular type telephone(RJ-11) socket one gang with safety shutter, duly erected on provided plate and box with wiring connections complete.
76Supplying and erecting ISI mark modular type T.V. socket single outlet, duly erected on provided plate and box with wiring connections complete.
77Supplying & installing co-axial copper cable low voltage grade RG-6 as per specification No. WG-TW
78Supplying and fixing M.S. box with Phenolic laminate plate 4- way splitter box for TV antennacomplete as required.
79Supplying and fixing of 1 or 2 module (75mm x75mm) size GI boxes with modular base and cover plate for modular switches in recess etc complete as required
80Supplying & installing UTP networking cat-6 cable suitable for LAN / WAN Computer net-working as per specification No. WG-COC/NC
81Supplying and fixing 24 port patch panel with tool-less keystone jacks in provided U Rack complete as per specification no. WG-NAS/PP
82TOTAL SUB HEAD IV:
83SUB HEAD - V: UPS (UNINTERRUPTED POWER SUPPLY)
84Supplying, installing, testing and commissioning of 1400 VA to 1600 VA Digital pure sine wave inverter based on Insulated Gate Bipolar Transistor (IGBT) technology single phase 230V,50 Hz complete as per specification no. APINV (Without batteries)
85TOTAL SUB HEAD V:
86Sub-Head - VI -CCTV AND PA SYSTAM
87Video Surveillance System(IP CCTV)
88Supplying, installation, testing and commissioning of 2 megapixels resolution Network Dome Camerafor true HD quality images,2.8 – 12 mm varifocal lens,True Day/Night (TDN) functionality for true color image ,Motion Detection 4 Zones, Multi- Level Sensitivity Privacy Zones 4 Zones,SnapshootSupport JPEG format Password Protection Support Character Display Support(Channel /Date) ONVIF Yes,IR Illumination20-30M IR illuminators for clear images in low light conditions Wide Dynamic Range 3D noise reduction for sharper images and lower bandwidth use in low lightONVIF compliant complete in all respect.Make-Tyco/Mobotix/Pelco.
89Supply, installation, testing and commissioning of 2 megapixels resolution Network Bullet camera camera,Imager 1/2.8”SONY 2.43 mega low illumination CMOS,Video Compression. .H.264/MJPEG,Day/Night .Mechanical ICR,Minimum Illumination-0Lux/F1.4(IR ON) IR Illumination-40-50M,,Electronic Shutter-Auto/Manual(1/25~1/10000) Lens 2.8 – 12 mm varifocal lens,Resolution Main-stream:D1/Q1080P(960*540)/HD720P/ HD1080P 1-25/30fps,Digital Noise Reduction-3D,Wide Dynamic Range-Digital WDR Motion Detection -4 Zones, Multi- Level Sensitivity,Privacy Zones-4 Zones,Snapshoot-Support JPEG format,Password Protection-Support,Character Display-Support(Channel /Date).Regulatory Emissions-FCC Part 15 CE: EN55022,Immunity -CE: EN50130-4,IP Rating- IP66 rated enclosure to protect against dust and water damage ONVIF compliant .Make-Tyco/Mobotix/Pelco.
90Supply, installation, testing & commissioning of 12 Port PoE+ Switch with 2 SFP slots 12 x 10/100/1000 Base-T PoE+ ports and additional 2 100/1000X SFP PORTS Should support PoE+ as per IEEE 802.3 at with PoE budget of 100W.Should support STP, RSTP, MSTP, IGMP v1/v2/v3 snooping, STP root guard, Voice VLAN, MLD snooping (MLDv1 and v2), IEEE 802.3ac VLAN tagging IEEE 802.17/equivalent for sub 50ms ring protection in following scenario : single, dual fibre cuts in ring and when fibre cut at common shared link in between two or more rings.
91Supply, Installation, Testing and Commissioning of 8 Channel 4K NVR with specifications as follow: Processor Quad-core embedded processor; Operating System Embedded LINUX; IP Camera Input 16 channel; Two-way Talk 1 channel Input, 1 channel Output, RCA User Interface GUI; Video Output 2 HDMI, 1 VGA; Video Resolution 3840× 2160, 1920× 1080, 1280× 1024, 1280× 720, 1024× 768 Video Display Split 1st screen: 1/4/8/9/16/25/36 , 2nd screen: 1/4/8/9/16; Channel 16; Motion Detection MD Zones: 396(22×18); Video Loss Supports; Alarm Input 16 Channel, Low Level Effective, Green Terminal Interface; Alarm Output 6 Channel, NO/NC. Playback Play, Pause, Stop, Rewind, Fast play, Slow Play, Next File, Previous File, Next Camera, Previous Camera, Full Screen, Repeat, Shuffle, Backup Selection, Digital Zoom; Max User Account 128 users; Record Interval 1~120 min (default: 60 min), Pre-record: 1~30 sec, Post-record: 10~300 sec; Ethernet 2 RJ-45 port (10/100/1000Mbps); Interface Ports 2 HDMI, 1 VGA, 4 ports (2 Rear USB3.0,2 Front USB2.0), 1 eSATA port, 1 RS485, 1 RS232, 2 RJ45; Protocols HTTP, TCP/IP, IPv4/IPv6, UPNP, RTSP, UDP, SMTP, NTP, DHCP, DNS, IP Filter, PPPOE, DDNS, FTP, Alarm Server, IP Search, ONVIF 2.4, CGI Conformant; Power Supply Single, AC 100~240V, 50/60 Hz; Power Consumption <16.7W (without HDD); Working Temp -10 ~+55°C / 10~90%RH / 86~106kpa;Certifications: UL,FCC ,CE, ISO certified.
92Supply, Installation, Testing and Commissioning of 4 TB Internal Surveillance Hard Disk for recording .
93Supply, Installation, Testing & Commissioning of 9U Rack with specifications as follows: Width x Depth: 550mm(width) * 500mm (Depth); Height: 9U; Ventilation: Fan 90CFM 230V AC fitted on rack top; Provisions:Front toughened glass with lock and key; Wiring: 1U Cable Manger Metal with PVC Loop; Cable Manager: On bottom of Rack; Power Distribution: PDU 6 Point 5Amp Socket, indian round pin with power Cable; Accessories : Mounting hardware packet of 10 piece.
94Supplying and fixing of HDMI Cable 3 mtrs length.
95Network Wiring for Cameras/devices with CAT 6e cable from NVR in exposed / recessed 25 mm dia MS Conduit including termination and providing/fixing 1.2 mm thick GI box with grid plates with earthing complete in all respect.
96Power wiring for Cameras/devices with 3 x 1.5 sq mm FRLS wire in exposed / recessed 25 mm dia MS Conduit including termination and providing/fixing 1.2 mm thick GI box with grid plates with earthing complete in all respect.
97TOTAL SUB HEAD VI:
98Sub-Head - VII - DISTRIBUTION PANELS
99Design, manufacture, supply,including supervision during installation, testing and commissioningof 2 mm thick MS sheet steel fabricated cubicle type Panel dust and verminproof complete with hinged and lockable doors .The Sheet Steel shall under go minimum eight tank treatment followed by finishing treatment of powder coating with 70 micron minimum thickness. All the panels shall be floor mounted and dead front construction complete with interconnections.
100Note:-
101The panels shall beFRONT operated, with cable entry from the top.Earth bus shall be part of the panel.) (All MCB to be "C" Curve)
102The following provisions shall be required to be made in the Distribution Panel as detailed below:
103All live accessible parts shall be shrouded with 1mm thick polycarbonate/3 mm thick FRP sheet and all equipment shall be finger touch proof. The busbar insulation shall be with heat shrinkable sleeves according to the colour code. SMC shrouds and busbar supports shall be used. All MCCB door handle shall be interlocked and lockable in OFF position.
104Galvanised hardware with zinc passivation shall be used in fabrication of Switchboards.
105Suitable Aluminium earth bus to be provided throughout the length of Switchboards.
106All indication lamps / illuminated push buttons shall be LED type.
107Coil of all motor starters shall be fed from 440 V / 230 V Control Transformer.
1082A SP MCBs shall be used as backup protections.
109All MCCBs shall be variable plug setting type with thermal magnetic up to 630 A rating and with microprocessor based releases above 630 A rating, line load reversibility, Ics = 100% Icu,& rotary handle.
110All control& power wiring shall be broughtout upto the cable alley in the terminal blocks.
111An approval shall be taken for each panel before manufacturing.
112Provision of one 6/16 amp socket & compartment lighting for each vertical section of main panel.
113Illuminated push button on Starter Panels of Pumps.
114Interlocking / Auto start command terminals for starter Panels.
115All breaking Capacity for ACB to be Ics=100%Icu and Icw for 1 sec..
116All breaking Capacity for MCCB to beIcs=100%Icu.
117All MCB to be C Curve
118Pavilion Panel
119Incoming:
1201 no. of 100Amp FPMCCB of 16 KA breaking capacity &Trip setting as required.
121Metering for incoming:
122Digital Multifunction meter (MFM-4) with RS-485 communication port for measurement ofPF, V, A & Hz , equivalent to EM6459, with CT as required.
123Phase indicating lamps RYBwith 6 Amps SP MCB back up.
124Bus Bars:
125Electrolytic high conductivity Aluminium three phase and neutral busbars rated at 150 Amps, insulated with heat shrinkable coloured PVC sleeves & clip on shrouds for joints. Current density of Bus Bar to be 1.3 sq.mm / amp.
126Outgoing (All MCB/MCCB shall be suitable for motor duty):
1273 Nos. 63A FP MCB of 10 KA breaking capacity.
1282 Nos. 63A DP MCB of 10 KA breaking capacity.
129Pavilion Panelas described above shall be complete with all interconnections, risers, internal wiring, labels, terminal blocks etc. complete as required.
130TOTAL SUB HEAD VII:
131Sub-Head -VIII- MISCELLANEOUS ITEMS CABLE & SAFETY CHART
132Supplying, erecting & terminating XLPE armoured cable 3½ core 35 sq. mm. aluminium conductor with continuous 5.48 sq. mm. (12 SWG) G.I. earth wire complete erected with glands & lugs, on wall/ trusses/pole or laid in provided trench/ pipe as per specification no. CB-LT/AL
133Supplying, erecting & terminating XPLE armoured cable 4 core 16 sq. mm. aluminium conductor with continuous 5.48 sq. mm. (12 SWG) G.I. earth wire complete erected with glands & lugs, on wall/ trusses/pole or laid in provided trench/ pipe as per specification no. CB-LT/AL
134Providing & erecting epoxy outdoor / indoor end termination kit for LT XLPE armoured cable 2.5 to 16 sq. mm. cable, with necessary material as per specification no. CB-JT/LT
135Providing & erecting epoxy outdoor / indoor end termination kit for LT XLPE armoured cable 25 to 50 sq. mm. cable, with necessary material as per specification no. CB-JT/LT
136Supplying and laying (including excavation of suitable width & depth up to 90 cm) 200 mm outside dia, double wall corrugated pipes (DWC) of HDPE for enclosing cable below ground/road surface, to required depth complete.
137TOTAL SUB HEAD VIII:
138SUB-HEAD -IX: EARTHING
139Providing earthing with galvanized iron earth plate size 60 x 60 x 0.6 cm complete with all materials, testing & recording the results as per specification no. EA-EP
140Providing earthing with copper earth plate size 30 x 30 x 0.315 cm complete with all materials, testing & recording the results as per specification no. EA-EP
141Supplying and erecting aluminium strip of required sizes used for earthing on wall and/or any other purpose with necessary aluminium clamps fixed on wall painted with bituminous paint in an approved manner with joints required. As per specification no EAEP.
142Supplying and erecting copper strip of required size used for earthing on wall and/or any other purpose with necessary copper clamps fixed on wall painted with bituminous paint in an approved manner with joints required. As per specification no. EA-EP.
143Supplying and erecting GI earth wire of high purity of different sizes used for earthing or any other purposes on wall with necessary G. I. Clamps fixed on wall/cable/ conduit with screws in an approved manner.
144Providing pipe type earthing with 40mm. dia. G.l. pipe or 20 mm dia. G.l. Rod complete with all materials as per specification no. EAEP
145TOTAL SUB HEAD IX:
146SUB-HEAD -X: INTELLIGENT FIRE ALARM SYSTEM
147Supplying, installing, testing and commissioning manual call point (Pill box) with break glass push button in metal enclosure complete as per specification no. FF-FAAS/MCP
148Supplying, installing, testing and commissioning hooters with CRCA enclosure complete as per specification no. FF-FAAS/HTR
149TOTAL SUB HEAD X:
150SUB-HEAD -XI:-EXTERNAL LIGHTING (Cricket GROUND)
151Supplying, erecting & terminating XLPE armoured cable 2 core 6 sq. mm. aluminium conductor with continuous 5.48 sq. mm. (12 SWG) G.I. earth wire complete erected with glands & lugs, on wall/ trusses/pole or laid in provided trench/ pipe as per specification no.CB-LT/AL
152Supplying, erecting & terminating XLPE armoured cable 2 core 10 sq. mm. aluminium conductor with continuous 5.48 sq. mm. (12 SWG) G.I. earth wire complete erected with glands & lugs, on wall/ trusses/pole or laid in provided trench/ pipe as per specification no. CB-LT/AL
153Supplying, erecting & terminating XLPE armoured cable 4 core 6 sq. mm. aluminium conductor with continuous 5.48 sq. mm. (12 SWG) G.I. earth wire complete erected with glands & lugs, on wall/ trusses/pole or laid in provided trench/ pipe as per specification no. CB-LT/AL
154Supplying, erecting & terminating XLPE armoured cable 3½ core 50 sq. mm. aluminium conductor with continuous 5.48 sq. mm. (12 SWG) G.I. earth wire complete erected with glands & lugs, on wall/ trusses/pole or laid in provided trench/ pipe as per specification no. CB-LT/AL
155Providing & erecting epoxy outdoor / indoor end termination kit for LT XLPE armoured cable 2.5 to 16 sq. mm. cable, with necessary material as per specification no. CB-JT/LT
156Providing & erecting epoxy outdoor / indoor end termination kit for LT XLPE armoured cable 25 to 50 sq. mm. cable, with necessary material as per specification no. CB-JT/LT
157Supplying & erecting mains with 3x2.5 Sq.mm F.R copper PVC insulated wire laid in providedonduit/trunking/inside pole/Bus bars or any other places as per specification No: WGMA/ BW
158Supplying and laying (including excavation of suitable width & depth up to 90 cm) 200 mm outside dia, double wall corrugated pipes (DWC) of HDPE for enclosing cable below ground/road surface, to required depth complete.
159Supplying and erecting steel tubular swaged pole 139.7 x 114.3 x 88.9 mm. dia with 4.5x3.65x3.25 mm thickness (4.5 + 1.75 + 1.75 m) length respectively and total 8 m long with pole cap, base plate in provided foundation.(weight 101 kg.) as per specification no. OH-PL/STP
160High Mast
161Supplying and erecting 12.5 m (clear height) High Mast (Top- 150mm, Bottom- 360mm) with lowering and raising motorized unit, lantern carriage assembly suitable for max. 6 nos. luminaries and its control gear box, lightning finial arrangement for fixing aviation light and foundation bolts on provided foundation as per specification no.OH-PL/HM (excluding luminaries ).
162Supplying and erecting 25 m (clear height) High Mast (Top-150mm, Bottom- 540mm) with lowering and raising motorized unit, lantern carriage assembly suitable for max. 12 nos. luminaries and its control gear box, lightning finial arrangement for fixing aviation light and foundation bolts on provided foundation as per specification No. OH-PL/HM (excluding luminaries).
163Supplying and erecting LED Flood light fitting of 120W, including lamp, with PF > 0.95,class IP 65 and above Housing of pressure die cast aluminium alloy and heat sink extruded aluminium complete per specification No FG-ODF/FLS-2 Specification of light :- (Alpha 120W High-efficiency IP66 LED floodlight design in aluminium pressure die-cast housing for better heat dissipation. Colour Temprature 5700K (cool white), Rated Lumen : 10000Lm, LED module with SMD LED package mounted with PC lens to ensure better uniformity of light distribution, Front cover: Toughened glass, Lumen maintenance: 50,000 Hrs @ L70 , Size Dimensions L : 324mm, W : 328mm, H: 139mm)
164Supplying and erecting LED Flood light fitting of 200W, including lamp, with PF > 0.95,class IP 65 and above Housing of pressure die cast aluminium alloy and heat sink extruded aluminium complete per specification No FG-ODF/FLS-2 Specification of light :- Alpha 200W High-efficiency IP66 LED floodlight design in aluminium pressure die-cast housing for better heat dissipation. Colour Temprature 5700K (cool white), Rated Lumen : 20000Lm, LED module with SMD LED package mounted with PC lens to ensure better uniformity of light distribution, Front cover: Toughened glass, Lumen maintenance: 50,000 Hrs @ L70, Size Dimensions L : 324mm, W : 328mm, H: 139mm
165Supplying and erecting LED street light fitting 100W, including lamp, with PF > 0.95 class IP 65 and above housing of pressure die cast aluminium alloy and heat sink extruded aluminium complete per specification No FG-ODF/FLS-2. Specification of light :- Fiesta Plus 110W Highly efficient front/top maintainable IP66 LED street-light with aluminium pressure die-cast housing, toughened glass in the front and peanut lens for batwing light distribution.Colour Temprature 5700K (cool white), Rated Lumen : 11000Lm, Dimensions L : 446mm, W : 205mm, H : 85mm, Pole OD : 60mm
166F.P.(External Lighting)
167Design, manufacture,Supply, Installation, testing and commissioning at works ofDouble door panel fabricated with minimum 2mm thick CRCA sheet, Conform to IS Specification, with IP-55 enclosure protection, as per IS-2137(Revised), floor mounting free standing on a suitable massanory pedestal outdoor type panel,provided with hinged detachable and lockable outer opening doors with the following incoming/outgong MCCB/ MCBs mounted therein including making connections/ interconnections, earthing, painting etc. as required.The panel shall have canopy arrangement on the top.All MCB to be C curve .
168Feeder Pillar
169Incoming
170The incoming shall comprise the following :-
1711 No 100 A FP MCCB, 16 KA service breaking capacity with heavy duty solid neutral link alongwith Earth fault relay and CBCT.
172Metering for incoming:
173Digital Multifunction meter (MFM-4) with RS-485 communication port for measurement ofPF, V, A & Hz , equivalent to EM6459, with CT as required.
174Phase indicating lamps RYBwith 2 Amps SP MCB back up.
175Bus Bars
17680 Amps TPN Aluminium Bus Bars of suitable length Bus bars shall be colour coded and insulated by heat shrinkable sleaves & clip on shrouds for joints. The current density of Bus bar shall be 1.2 sq.mm./amp.
177Outgoing (All MCB shall be suitable for motor duty& with heavy duty detachable solid neutral link ):
17836 nos 25A DP MCB 10 KA breaking capacity controlled by and including providing 63 DP MCB, 63 A DP contactor and Timer.
179Feeder Pillardescribed as above and all as per specification.
180Earthing
181Providing earthing with galvanized iron earth plate size 60 x 60 x 0.6 cm complete with all materials, testing & recording the results as per specification no. EA-EP
182Supplying and erecting aluminium strip of required sizes used for earthing on wall and/or any other purpose with necessary aluminium clamps fixed on wall painted with bituminous paint in an approved manner with joints required. As per specification no EAEP.
183Supplying and erecting GI earth wire of high purity of different sizes used for earthing or any other purposes on wall with necessary G. I. Clamps fixed on wall/cable/ conduit with screws in an approvedmanner.
184Providing pipe type earthing with 40mm. dia. G.l. pipe or 20 mm dia. G.l. Rod complete with all materials as per specification no. EAEP
185TOTAL SUB HEAD XI:
186TOTAL ELECTRICAL WORK
187EXTERNAL PLUMBING WORKS
188(EXTERNAL SEWERAGE SYSTEM)
189Excavating trenches of required width for pipes, cables, etc including excavation for sockets, and dressing of sides, ramming of bottoms, depth upto 1.5 m including getting out the excavated soil, and then returning the soil as required, in layers not exceeding 20 cm in depth, including consolidating each deposited layer by ramming, watering, etc. and disposing of surplus excavated soil as directed, within a lead of 50 m :
190All Kind of Soil
191Pipes, cables etc. exceeding 80 mm dia. but not exceeding 300 mm dia.
192Providing, laying and jointing glazed stoneware pipes class SP-1 with stiff mixture of cement mortar in the proportion of 1:1 (1 cement : 1 fine sand) including testing of joints etc. complete :
193150 mm diameter
194200 mm diameter
195250 mm diameter
196Providing and laying cement concrete 1:5:10 (1 cement : 5 coarse sand : 10 graded stone aggregate 40 mm nominal size) all-round S.W. pipes including bed concrete as per standard design :
197150 mm diameter S.W. pipe
198200 mm diameter S.W. pipe
199250 mm diameter S.W. pipe
200Providing and laying cement concrete 1:5:10 (1 cement : 5 coarse sand : 10 graded stone aggregate 40 mm nominal size) up to haunches of S.W. pipes including bed concrete as per standard design :
201150 mm diameter S.W. pipe
202200 mm diameter S.W. pipe
203250 mm diameter S.W. pipe
204Providing and fixing square-mouth S.W. gully trap class SP-1 complete with C.I. grating brick masonry chamber with water tight C.I. cover with frame of 300 x300 mm size (inside) the weight of cover to be not less than 4.50 kg and frame to be not less than 2.70 kg as per standard design:
205180x150 mm size P type
206With Sewer bricks conforming to IS : 4885
207Constructing brick masonry manhole in cement mortar 1:4 ( 1 cement : 4 coarse sand ) with R.C.C. top slab with 1:1.5:3 mix (1 cement : 1.5 coarse sand (zone- III) : 3 graded stone aggregate 20 mm nominal size), foundation concrete 1:4:8 mix (1 cement : 4 coarse sand (zone- III) : 8 graded stone aggregate 40 mm nominal size), inside plastering 12 mm thick with cement mortar 1:3 (1 cement : 3 coarse sand) finished with floating coat of neat cement and making channels in cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) finished with a floating coat of neat cement complete as per standard design :
208Inside size 90x80 cm and 45 cm deep including precast RCC Cover with frame (light duty) 455x610 mm internal dimensions, total weight of cover and frame to be not less than 38 kg (weight of cover 23 kg and weight of frame 15 kg) :
209With Sewer bricks conforming to IS : 4885
210Inside size 120x90 cm and 90 cm deep including C.I. cover with frame (heavy duty) 560 mm internal diameter, total weight of cover and frame to be not less than 208 kg (weight of cover 108 kg and weight of frame 100 kg)
211With Sewer bricks conforming to IS : 4885
212Extra for depth for manholes :
213Size 90x80 cm
214With Sewer bricks conforming to IS : 4885
215Size 120x90 cm
216With Sewer bricks conforming to IS : 4885
217Providing orange colour safety foot rest of minimum 6 mm thick plastic encapsulated as per IS : 10910, on 12 mm dia steel bar conforming to IS: 1786, having minimum cross section as 23 mmx25 mm and over all minimum length 263 mm and width as 165 mm with minimum 112 mm space between protruded legs having 2 mm tread on top surface by ribbing or chequering besides necessary and adequate anchoring projections on tail length on 138 mm as per standard drawing and suitable to with stand the bend test andchemical resistance test as per specifications and having manufacture’s permanent identification mark to be visible even after fixing, including fixing in manholes with 30x20x15 cm cement concrete block 1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size) complete as per design.
218Making connection of drain or sewer line with existing manhole including breaking into and making good the walls, floors with cement concrete 1:2:4 mix (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) cement plastered on both sides with cement mortar 1:3 (1 cement : 3 coarse sand), finished with a floating coat of neat cement and making necessary channels for the drain etc. complete :
219For pipes 250 to 300 mm diameter
220TOTAL (EXTERNAL SEWERAGE SYSTEM) C/F TO SUMMARY
221(EXTERNAL STORM WATER SYSTEM)
222Earth work in excavation by mechanical means (hydraulic excavator)/manual means over areas (exceeding 30cm in depth. 1.5m in width as well as 10 sqm on plan) including disposal of excavated earth, lead upto 50m and lift upto 1.5m; disposed earth to be levelled and neatly dressed.
223Providing and laying non-pressure NP2 class (light duty) R.C.C. pipes with collars jointed with stiff mixture of cement mortar in the proportion of 1:2 (1 cement : 2 fine sand) including testing of joints etc. complete :
224150 mm dia. R.C.C. pipe
225250 mm dia. R.C.C. pipe
226300 mm dia. R.C.C. pipe
227Constructing brick masonry road gully chamber 50x45x60 cm with bricks in cement mortar 1:4 (1 cement : 4 coarse sand) including 500x450 mm pre-cast R.C.C. horizontal grating with frame complete as per standard design :
228With common burnt clay F.P.S. (non modular) bricks of class designation 7.5
229Constructing brick masonry road gully chamber 110x50x77.5 cm with bricks in cement mortar 1:4 (1 cement : 4 coarse sand) including 500x450 mm precast R.C.C. horizontal grating with frame and vertical grating complete as per standard design :
230With common burnt clay F.P.S. (non modular) bricks of class designation 7.5
231Providing and laying Non Pressure NP-3 class (Medium duty) R.C.C. pipes including collars/spigot jointed with stiff mixture of cement mortar in the proportion of 1:2 (1 cement : 2 fine sand) including testing of joints etc. complete
232450 mm dia RCC pipes
233Making connection of drain or sewer line with existing manhole including breaking into and making good the walls, floors with cement concrete 1:2:4 mix (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) cement plastered on both sides with cement mortar 1:3 (1 cement : 3 coarse sand), finished with a floating coat of neat cement and making necessary channels for the drain etc. complete :
234For pipes 250 to 300 mm diameter
235Total (EXTERNAL STORM WATER SYSTEM) C/F TO SUMMARY
236(EXTERNAL DOMESTIC WATER SYSTEM)
237Providing and fixing G.I. pipes complete with G.I. fittings including, trenching and refilling etc. external works
23825 mm dia nominal bore
23932 mm dia nominal bore
240Painting G.I. pipes and fittings with two coats of anti-corrosive bitumastic paint of approved quality :
24125 mm dia nominal bore
24232 mm dia nominal bore
243Providing and filling sand of grading zone V or coarser grade all-round the G.I. pipes in external work.
24425 mm dia nominal bore
24532 mm dia nominal bore
246Providing and fixing gun metal gate valve with C.I. wheel of approved quality
247(screwed end) :
24825mm nominal bore
24932mm nominal bore
25040mm nominal bore
25150mm nominal bore
252Constructing masonry Chamber 60x60x75 cm inside, in brick work in cement mortar 1:4 (1 cement : 4 coarse sand) for sluice valve, with C.I. surface box 100mm top diameter, 160 mm bottom diameter and 180 mm deep ( inside) with chained lid and RCC top slab 1:2:4 mix (1 cement : 2 coarse sand : 4 graded stone aggregate 20mm nominal size ) , i/c necessary excavation, foundation concrete 1:5:10 (1 cement : 5 fine sand : 10 graded stone aggregate 40 mm nominal size) and inside plastering with cement mortar 1:3 (1 cement : 3 coarse sand) 12 mm thick, finished with a floating coat of neat cement complete as per standard design :
253With common burnt clay F.P.S.(non modular) bricks of class designation 7.5
254TOTAL (EXTERNAL DOMESTIC WATER SYSTEM) C/F TO SUMMARY
255TOTAL (EXTERNAL PULMBIMG)
256PAVILION BUILDING - CRICKET GROUND FIRE FIGHTING WORKS
257SUB HEAD-A (PIPING & VALVES)
258Providing, laying, testing & commissioning of "C" class heavy duty MS pipe conforming to IS 3589/IS 1239 including Welding, fittings like elbows, tees, flanges ,tapers, nuts bolts, gaskets etc. and fixing the pipe on the wall/ceiling with suitable clamp/support frame and painting with two or more coats of synthetic enamel paint of required shade complete as required :
25925 mm dia.
26050 mm dia.
261100mm dia
262Providing, installation, testing and commissioning of non-return valve of following sizes confirming to IS:5312 complete with rubber gasket, GI bolts, nuts,washers etc.as required :
263Providing and fixing gun metal gate valve with C.I. wheel of approved quality (screwed end) :
26425 mm dia.
265Supplying, fixing, testing and commissioning of butterfly valve of PN 1.6 rating with bronze/gunmetal seat duly ISI marked complete with nuts, bolts, washers, gaskets conforming to IS 13095 of following sizes as required :
266100 mm dia.
267Providing and fixing dial type pressure gauge with isolation cock and copper pipeat hydrant station.
268Providing,installation,testingandcommissioningof stainlesssteelY-strainerfabricatedoutof1.6mm thickstainlesssteel,Grade304,sheetwith3mmdia holes with stainless steel flange.
269Providing & fixing of pressure switch in M.S. pipe line including connection etc. as required.
270TOTAL SUB HEAD-A (PIPING & VALVES) C/F TO SUMMARY
271SUB HEAD-B (FIRE HYDRANT ACCESSORIES)
272Supplying and fixing single headed internal hydrant valve with instantaneous Gunmetal/Stainless Steel coupling of 63 mm dia with cast iron wheel ISI marked conforming to IS 5290 (Type -A) with blank Gunmetal/Stainless Steel cap and chain as required :
273Single headed Gunmetal
274Supplying and fixing first-aid Hose Reel with MS construction spray painted in post office red, conforming to IS 884 complete with the following as required. 20 mm nominal internal dia water hose thermoplastic (Textile reinforced) type -2 as per IS: 12585 20 mm nominal internal dia gun metal globe valve & nozzle. Drum and brackets for fixing the equipmets on wall. Connections from riser with 25 mm dia stop gun metal valve & M.S. Pipe and socket.
27530m
276Supplying and fixing 63 mm dia, 15 m long RRL hose pipe with 63 mm dia male and female couplings duly bound with GI wire, rivets etc. conforming to IS 636 (type-A) as required :
277Gun Metal
278Supplying & fixing 63 mm dia gun metal short branch pipe with 20 mm nominal internal diameter size nozzle conforming to IS 903 suitable for instantaneous connection to interconnect hose pipe coupling as required :
279Gun Metal
280Providing and fixing doorwith frame for all internal fire hydrants fabricated from 20x20x3mm and40x20x3 mm aluminium hollow box sections mounted with 3 no. of 100 mm Aluminium butt hinge onAluminium angle frame of 45x45x5mm size with hold fasts fixed to wallwithP.C.C. (1:2:4) blocks 100x100x100 mm including 2 nos allen key lock for locking along with padlock arrangement& fully glazed with 4 mm thick float glass approved by local Fire Authority, powder coated fire red finish with " fire hose" written on front suitable to house 15 mm long two length of canvas hose with couplings, one no of branch pipe, one fire mans axe and two numbers of portable extinguishers, first aid fire hose and supports for hoses, branch pipes, Axe and hose reel. Size 1200x 600 mm complete as per approved design including necessary fixing arrangement for hoses & axe and branch pipe.)
281Supplying and fixing of Fire Man"s Axe with heavy insulated rubber tested upto 20 KV and confirming to IS :926.
282Supplying and fixing orifice plate made out of 6 mm thick stainless steel (Grade 304) with orifice of required size to be fitted between flange & landing valve of external and internal hydrants to reduce pressure at the outlet to the level of 3.5 kg/cm2 complete as required.
283Supplyingandfixingoffirebrigadeconnectionof cast iron body with gun metal male instantaneous inlet couplingscompletewithcapandchainasreqd.for suitabledia MS pipe connectionconforming to IS 904 as required :
2842 way-100 mm dia M.S. Pipe
285Supplying and fixing air vessel made of 250 mm dia, 8 mm thick MS sheet, 1200 mm in height with air release valveontopandflangedconnectiontoriser,drain arrangementwith25mmdiagunmetalwheelvalve withrequiredaccessories,pressuregaugeand paintingwith synthetic enamel paint of approved shade as required.
286TOTAL SUB HEAD-B (FIRE HYDRANT ACCESSORIES) C/F TO SUMMARY
287SUB HEAD-C (FIRE EXTINGUISHERS & MISC. ITEMS)
288Providing and fixing Carbon-di-oxide fire extinguishers consisting of welded M.S cylindrical body, squeeze lever discharge valve fitted with internal discharge tube, 30cms long high pressure discharge hose, dischargenozzle, suspension bracket, confirming to IS: 15683 finished externally with redenamelpaint andfixed towall with brackets with rawl plug/dash fasteners complete with internal charge. Capacity 4.5 kg. ISI Marked.( Contractor should submit test certificate form manufacturer along with serial number of every extinguishers supplied.)
289Providing and fixing waterCo2(ISI marked) extinguishers includingall accessoriesas per IS specification with wall bracket with rawl plug
290Capacity 9 liters.(IS:15683)
291Providing and fixing of self illuminated / auto glow "EXIT" signs printed on photoluminescentsheet containing self illuminated base chemical, of appropriate size not less than 400 x 150 mm, suspended from ceiling or fixed to the walls with accessories as required and as directed at site.
292TOTAL SUB HEAD-C (FIRE EXTINGUISHERS & MISC. ITEMS) C/F TO SUMMARY
293SUB HEAD-D (FIRE PUMPS & ACCESSORIES)
294Supplying,installation,testingandcommissioningof electric driven terrace pump suitable forautomatic operationandconsistingoffollowing,completeinall
295respects, as required: (Terrace Pump)
296(a)Horizontal type, multistage, centrifugal, split casing pump of cast iron body & bronze impeller with stainless steel shaft, mechanical confirming to IS : 1520
297b)SuitableHPsquirellcageinductionmotorTEFCtype suitable for operation on 415 volts, 3 phase, 50 Hz, AC supplywithIP55classofprotectionforenclosure, horiziontalfootmountedtypewithClass-"F"insulation,conforming to IS-325.
298(c)M.S.fabricated common base plate, coupling, coupling guard, foundation bolts etc.as required.
299(d)Suitablecementconcretefoundationdulyplastered and with anti vibration pads.
300450 lpm at 35 m Head
301Providingandfixingliquidlevel controller for fire pumpto stop fire pump in caseoflow level of water in tank , cost of conduit, cable and panel including making connection to pump panel and commissioning complete.
302Float type Sensor with panel and installation
303Providing and fixing rubber expansion joint (to provide relief from stresses at pipe flanges)as per specification of the manufacturers and direction of Engineer in chief PN-16 rating
304100 mm dia
305150 mm dia
306TOTAL SUB HEAD- D (FIRE EXTINGUISHERS & MISC. ITEMS) C/F TO SUMMARY
307TOTAL FIRE FIGHTING WORKS
308HVAC Works
309GENERAL NOTES:
310All items of work under this Contract shall be executed strictly to fulfill the requirements laid down under “Basis of Design” in the specifications. Type of equipment, material specification, methods of installation and testing and type of control shall be in accordance with the specifications, approved shop drawings and the relevant Indian Standards, however capacity of each component and their quantities shall be such as to fulfill the above mentioned requirement.
311The unit rate for all equipments or materials shall include cost in RUPEES for equipment and materials including all taxes and duties, including forwarding, freight, insurance and transport into Contractor’s store at site, storage, installation, testing, balancing, commissioning and other works as required.
312The rate for each item of work included in the Schedule of Quantities shall, unless expressly stated otherwise, include cost of :
313All materials, fixing materials, accessories, appliances tools, plants, equipment, transport, labour and incidentals required in preparation for and in the full and entire execution, testing, balancing, commissioning and completion of work called for in the item and as per Specifications and Drawings.
314Wastage on materials and labour.
315Loading, transporting, unloading, handling/double handling, hoisting to all levels, setting, fitting and fixing in position, protecting, disposal of debris and all other labour necessary in and for the full and entire execution and for the job in accordance with the contract documents, good practice and recognize principles.
316Liabilities, obligations and risks arising out of Conditions of Contract.
317All requirements of Specifications, whether such requirements are mentioned in the item or not. The Specifications and Drawings where available, are to be read as complimentary to and part of the Schedule of Quantities and any work called for in one shall be taken as required for all.
318In the event of conflict between Schedule of Quantities and other documents including the Specifications, the most stringent shall apply. The interpretation of the Consultant/Project Manager shall be final and binding.
319All equipments, quantities and technical data indicated in this Schedule are for the Contractor’s guidance only, these are based on the documents prepared by the Consultant. This schedule must be read in conjunction with other documents.The Contractor shall be paid for the actual quantity of work executed by him in accordance with the approved Shop Drawings at the contract rates.
320This Schedule shall be fully priced and the extensions and totals duly checked. The rates for all items shall be filled in INK including NILitems.
321No alteration whatsoever is to be made to the text or quantities of this Schedule unless such alteration is authorised in writing by Consultant. Any such alterations, notes or additions shall, unless authorized in writing, be disregarded when tender documents are considered
322In the event of an error occurring in the amount of the Schedule, as a result of wrong extension of the unit rate and quantity, the unit rate quoted by the tenderer shall be regarded as firm and the extensions shall be amended on the basis of rates.
323Any error in totaling in the amount column and in carrying forward total shall be corrected. Any error, in description or in quantity, omission of items from this Schedule shall not vitiate this Contract but shall be corrected and deemed to be variation required by the Consultant/Project Manager.
324Rates have been called for a number of items of works, as alternatives which, for the present do not form part of the total value of tender. However the rates for these items shall be quoted, with due care so that in the event of choice of an alternative item of work, said rate shall form part of the contract and shall not violate the contract any way.
325The Contractor shall procure and bring Materials/Equipment to the site only on the basis of drawings approved for construction and shop drawings and not on the basis of Schedule of Quantities which are provisional only. This also applies to the Contractor’s requisition for Owner supplied materials.
326Minimum gauge for duct fabrication shall be 24 gauge wether it is site fabricated or factory fabricated.
327Electrical for HVAC
328All the starters of HVAC equipments shall have BMS compatibility.
329In specific, each starter shall have-
330AUTO/MANUAL switch/status
331Accept start/stop command from BMS
332PFC to BMS for run status & trip status.
333PFC to BMS for Auto/Manual.
334SUB-HEAD-I-VRF/INDOOR UNIT
335Supplying, erecting, testing and commissioning 16 HP, VRF / VRV air conditioning system, out door unit (ODU) complying type-IV OEM standards working on HFC free refrigerant R410A or other required/suitable green equivalent refrigerant, for cooling capacity delivering 100% at 47 deg. celcius and non stop cooling even at 56 deg. celsius and coefficient of performance (COP) 3.00 to 4.00, modular type horizontal/vertical hot air discharge suitable for total piping length upto 1000 metre operation in cooling mode with inverter based VRF/VRV technology microprocessor based control compressor starter/control panel complete with scroll compressor, air cooled anti corrosive copper condenser coil of suitable shape for increasing maximum heat transfer area, built in oil separator, accumulator and oil receiver, copper tube aluminium fin air cooled condenser, condenser fan with motor suitable for 415V ± 10%, 50 Hz, 3 phase power supply, internal copper refrigerant piping, internal wiring
336VRF TYPE INDOOR UNITS: (Tailor made Airhandling units and shall be procured from other vendors duly approved by the manufacturer of the VRV units)
337Supply, installation, testing and commissioning of VRF/VRV based ceiling suspended 4 Way cassette indor unit (IDU) compact / standard size of nominal cooling capacity 4.1TR ( 1218 cfm ) to 5.0TR ( 1624 cfm ) having EER as per BEE standards and specifications, suitable as per site requirement with swing louvers and adjustable blades from sides. Indoor Units complete with in-built drainage arrangements, fan, refrigerant liquid and refrigerant piping, cordless remote control, and fresh air port etc. IDU shall have anticorrosive coating suitable for coastal area complete in all respects, to operate on 1-phase, 230V, 50Hz, AC input supply, consisting with any additional refrigerant and oil charge as per requirement during installation and connected to the system complete.
338Supply, installation, testing and commissioning of VRF/VRV based ceiling suspended 4 Way cassette indor unit (IDU) compact / standard size of nominal cooling capacity 2.0TR ( 618 cfm ) / 2.3TR ( 671 cfm ) having EER as per BEE standards and specifications, suitable as per site requirement with swing louvers and adjustable blades from sides. Indoor Units complete with in-built drainage arrangements, fan, refrigerant liquid and refrigerant piping, cordless remote control, and fresh air port etc. IDU shall have anticorrosive coating suitable for coastal area complete in all respects, to operate on 1-phase, 230V, 50Hz, AC input supply, consisting with any additional refrigerant and oil charge as per requirement during installation and connected to the system complete.
339FITTINGS & CONTROLLERS
340SITC ofRemote controllers (Corded) for operation of indoor units. (For recirculation type only, for TFA / Recirculated AHU unitsit is a part of VRV kit)
341REFRIGERANT PIPING WORK
342Supplying, laying / fixing, testing and commissioning of appropriate nominal refrigerant copper pipe of 9.5 mm dia (OD) for liquid line / suction line supply and return piping of suitable gauge ( hard drawn copper pipe for liquid main line and for refrigerant ) along with necessary supports, hangers, clamps, vibration isolators and fittings such as bends, tees, valves, gauges, strainers with insulation of 19 mm thick elastomeric nitrile rubber along with application of multicoating suitable for use with VRV / VRF piping for protection against mechanical damages, fungal growth, flame spread, water permeance and ultra violet radiations complete with OEM standards of VRV / VRF air conditioning system.
343Supplying, laying / fixing, testing and commissioning of appropriate nominal refrigerant copper pipe of 12.7 mm dia (OD) for liquid line / suction line supply and return piping of suitable gauge ( hard drawn copper pipe for liquid main line and for refrigerant ) along with necessary supports, hangers, clamps, vibration isolators and fittings such as bends, tees, valves, gauges, strainers with insulation of 19 mm thick elastomeric nitrile rubber along with application of multicoating suitable for use with VRV / VRF piping for protection against mechanical damages, fungal growth, flame spread, water permeance and ultra violet radiations complete with OEM standards of VRV / VRF air conditioning system.
344Supplying, laying / fixing, testing and commissioning of appropriate nominal refrigerant copper pipe of 15.9 mm dia (OD) for liquid line / suction line supply and return piping of suitable gauge ( hard drawn copper pipe for liquid main line and for refrigerant ) along with necessary supports, hangers, clamps, vibration isolators and fittings such as bends, tees, valves, gauges, strainers with insulation of 19 mm thick elastomeric nitrile rubber along with application of multicoating suitable for use with VRV / VRF piping for protection against mechanical damages, fungal growth, flame spread, water permeance and ultra violet radiations complete with OEM standards of VRV / VRF air conditioning system.
345Supplying, laying / fixing, testing and commissioning of appropriate nominal refrigerant copper pipe of 22.2 mm dia (OD) for liquid line / suction line supply and return piping of suitable gauge ( hard drawn copper pipe for liquid main line and for refrigerant ) along with necessary supports, hangers, clamps, vibration isolators and fittings such as bends, tees, valves, gauges, strainers with insulation of 19 mm thick elastomeric nitrile rubber along with application of multicoating suitable for use with VRV / VRF piping for protection against mechanical damages, fungal growth, flame spread, water permeance and ultra violet radiations complete with OEM standards of VRV / VRF air conditioning system.
346Supplying, laying / fixing, testing and commissioning of appropriate nominal refrigerant copper pipe of 34.9 mm dia (OD) for liquid line / suction line supply and return piping of suitable gauge ( hard drawn copper pipe for liquid main line and for refrigerant ) along with necessary supports, hangers, clamps, vibration isolators and fittings such as bends, tees, valves, gauges, strainers with insulation of 19 mm thick elastomeric nitrile rubber along with application of multicoating suitable for use with VRV / VRF piping for protection against mechanical damages, fungal growth, flame spread, water permeance and ultra violet radiations complete with OEM standards of VRV / VRF air conditioning system.
347CONTROL CABLING
348Providing & fixing control cum transmission wiring of 2 core x 1.5 sqmm copper in suitable25 mm dia heavy duty PVC conduits or wall chasebetween indoor units and outdoor units and indoor units and remote controllers.
349Condensate Drain Piping
350Supply, installation, testing andcommissioningof condensatedrainwaterpiping of CPVC completewithfittingslikeelbows,tees,reducers, bends, U-traps, braided flexible pipe connections with GI clamps, flanges, supports, solvent etc. as required conforming to tender specificationsand of following sizes
35132 mm dia pipe
352TOTAL SUB-I
353SUB-HEAD-II-THERMAL INSULATION AND Y JOINT
354Drain Pipe Insulation:
355Supplying & installation of 6 mm thick closed cell nitrile rubber insulation with approved sample ofblack colour factory laminated fibre glass cloth with density 40-60 Kg/ Cum/ Aluminium foil faced XLPE insulation with density 25-30 Kg/Cum, class "O" complete as per specifications in the form of pre-formed pipe sections and complete in all respects as per specifications and drawingson condensate drain pipes of the following sizes:
356Quotedpriceshallbeinclusiveofadhesive and UV/mechanical protection using UV resistant paint/starbond coating spread over Glass cloth as per specifications.
35732mm dia
358Y or T- Joints /
359Supplying and installation of high pressure grade required size copper connection Y or T- Joints / refnet for liquid and suction line complete erected on wall/ceiling with supports/raceways, Nitrile rubber insulation, painting etc. with brazing and testing for leakages confirming the normal operation of the VRV / VRF air conditioning system.
360TOTAL SUB-II
361SUB-HEAD-III : ELECTRICAL WORK
362Preamble to BOQ for MCC , Distribution Boards & wall mounted Starter Panels
363General Notes & Specifications as given below shall be applicable to all panels.The vendors shall consider the following details in their item rates, wherever required:
364Supporting rigid steel framework.
365Cubicle type, 14 gauge CRCA  sheet steel enclosure.
366Panel Complete with interconnections and distribution bus bars.
367Proper bonding to earth.
368Painting/lettering  on Breakers and distribution boards,  the location  they serve,  Providing on each panel its circuit diagram.
369Providing cable clamps / supports within distribution boards cable alley.
370TPN  MCCBs  shall mean 3 pole MCCBs  with adequate size of neutral link.
371All MCBs shall be of minimum 10 KA breaking capacity.
372All motor feeders MCCBs shall be of motor duty.
373Distribution  panels shall be Powder Coated with Siemens gray paint shade no. RAL-7032 of IS-5.
374Degree of protection for following type of distribution panel enclosure shall be as per IS:13947-1993.
375IP 52 for indoor panels.
376IP 55 for outdoor panels with double door enclosure.
377All  MCCB’s   shall be provided with operating   mechanism  for door interlock.
378Current density of aluminium  shall be 1 sq mm for 1.0 amps for rated current of bus bars and current density of copper shall be 1 sq.mm for 1.25 amps for rated current of bus bars.
379Tinned copper earth bus shall be provided through out the length of each board.
380All measuring instruments (Meters) shall be of digital electronic with LED of approved make and compatible with BAS.
381All indicating lamps shall be LED type.
382All current/voltage transformers shall be cast resin type.
383All hinged door shall be earthed through 2.5 sq mm tinned braided copper wire.
384All panels shall have provision of the following:
385Pad locking of Switch board doors.
386Pad locking of MCCB’s handles in “OFF” Position.
387Additional set of C.T.s, potential free contacts, connectors, contactors with wiring etc are to be provided for BAS including space required for various transducers in Main Switch Board sections.  Only transducers shall be supplied by BAS contractor.
388All MCB’s used for protection of resistive and lightly inductive load shall be type “B” characteristic and inductive (motor) load shall be of type “C” characteristic and discharge lamps and UPS etc. shall be of type D characteristic.
389All incoming and outgoing air circuit breakers shall be placed on middle portion of the vertical in single tier formation.
390All PTs / control transformers shall be provided with centre tap earth secondary.
391All DOL & Star-Delta Starters shall be provided with voltage based SPPR (single phase preventor relay) and 2 nos. of Aux.Contacts for Remote operation/monitor.
392The Panel fabricator shall provide Aluminium Bus-bars link from Breakers wherever more than two nos. of cables are terminated in the breakers.
393Readymade 16SWG Sheet steel Enclosure with cutout For MCBs
394The  breaking  capacity of MCCB’s shall bementioned  panel  wise. All MCCB’s shall be with thermal magnetic releases upto 250 amps and miroprocessor based above 250 amps capacity, unless specified otherwise.
395All internal control wiring shall be heat resistant type.
396Bus bar chamber shall be provided at top only. Incoming and outgoing cable entry shall be from top/bottom as required.
397Live parts shall not be accessible after opening the door, Transparent acrylic sheet to be provided to cover the same.
398Spare contacts of ACBs / MCCBs / Relay / Contactor shall be wired upto terminal block.
399All Switchgear used in Starter Circuit shall be type-2 coordinated. Contactor rating shall be selected as per the kVAR rating of the capacitor bank from capacitor duty contactor range. Vendor to furnish the type-2 coordination chart and capacitor duty contactor selection chart.
400Protection Releases Microprocessor based (PRMB) & Thermal magnetic (PRTM) shall be as described below .
401Protection Release Microprocessor Based (PRMB-1)
402Over-current/long time protection range  105% - 120 % with Time setting
403short circuit /short time protection range  100% - 1000 % with Time setting
404Instantaneous short circuit Protection range  200% - 1500 % with Time setting
405Earth Fault Protection range  20% - 100 % with Time setting
406Under voltage & over voltage protection
407Reverse power
408Current unbalance
409Phase sequence
410Measurements
411Voltage
412Current
413Power (Active,Reactive & Apparent)
414Energy ((Active,Reactive & Apparent)
415Power factor
416Frequency
417Protection Release Microprocessor Based (PRMB-2)
418Over-current/long time protection range  105% - 120 % with Time setting
419short circuit /short time protection range  100% - 1000 % with Time setting
420Instantaneous short circuit Protection range  200% - 1500 % with Time setting
421Earth Fault Protection range  20% - 100 % with Time setting
422Measurements
423Current
424Protection Release Microprocessor Based (PRMB-3)
425Over-current/long time protection range  105% - 120 % with Time setting
426Instantaneous short circuit Protection range  200% - 1500 % with Time setting
427Protection Release Thermal-Magnetic Based (PRTM)
428Over-current
429Short circuit
430VFD STARTER
431Design, manufacture, supply, installation, testing and commissioning of the following cubicle type, dead front, sheet steel, wall mounted AHU starter panels including anchoring into the wall with following details:
432All outgoing shall be provided with Stop / Manual /Auto selector switch to facilitate operation through BAS. All starters shall be provided with potential free Contacts for Connections to Building Automation System.
433The panel shall include the following components and accessories.
43414G CRCA Powder Coated panel enclosure with earthing studs & hinged locable doors. IP52 Protection, suitable for 415V, 3 Phase, 4 wire, 50Hz system.
435Incomer switch shall be TP MCCB (motor duty) of required rating & 20KA fault withstand capacity. MCCB shall be with overload & short circuit protection.
436R,Y,B LED Type Phase indication lamps with control MCB"s.
437ON"/OFF/TRIPIndication LED Type lamp with control MCB.
438Digital voltmeter and digital ammeter with in built selector switches.
439VFD (Variable Frequency Drive) with all inbuilt features like protection against over load, short circuit & single phasing. VFD shall have inbuilt auto / manual / BMS operation functions selection & shall be BMS compatible. Drive shall have ON/OFF/Trip displays & metering & display of electrical parameters.Drive shall be Danfoss Vacon-20 series /Equivalent.
440View window to read VFD parameters.
441For on/off/remote and local operation, 3 pole single throw switch shall be provided in each AHU panel to facilitate override of the automatic operation.
442A fire detection relay module for tripping of AHU motor on receiving fire signal & fire damper interlocking. Necessary nos. of auxillary contactors & Relays shall be included in cost as required for the interlocking with smoke extraction fans & motorised firedampers.
443240/24V AC Step down transformerfor powering to 2 Way / 3 Way motorized valve with control MCB and wiring & conduiting upto valve in the chilled water line. 24V AC supply shall also be used for fire module relay.
4443 Nos of Single Pole MCB"s Shall be provided at the incoming section of the starter panel for DDC Panel , fire damper actuator & AHU limit switch/Bulk head lighting.
445Time delay relay for delayed automatic restart of air handling unit motor.
446Airwasherpanel shall have an additional set of On/Off push button with indication, set of contactor and overload relay for the operation of 1 no. pump and shall be BMS compatible
447Scrubber panel shall have additional set of On/Off push button with indication, set of contactor and overload relay for the operation of 1no. dry scrubberand shall be BMS compatible.
448Terminal block for power distribution.
449Panel shall have adequate ventilation arrangement for heat dissipated by VFD.
450Note: Vendor to include the cost of all related power& control cabling (for AHU door limit switch,Bulk head light etc) on GI cable tray along with copper earthing ,from airhandling unit motors to VFD control panels, from dry scrubber to control paneland from Airwasher pumps to control panel. (For sizes of cables ,refer to the detailed specifications of Electrical section).All cables shall be FRLS XLPE insulated armoured.
451The no. of VRF control panels/VFD starters shall be as per KW ratings given below:
452VRF Panel for 16HP KW Motor
453Isolator/MCB/ELCB Switches With Metal Enclosure
45463A MCCB (300mA),4pole switch for VRV Outdoor units with sheet metal enclosure, rain protection etc. as required to suit the site condition. (Enclosure shall be suitable for out door installation.)
455TOTAL SUB-III
456TOTAL HVAC WORK
457INTERNAL PLUMBING
458SANITARY INSTALLATIONS
459Providing and fixing European type white glazed earthenware coupled closet symphonic trap with symphonic low level white glazed 10 litres cistern with black backlite seat with all necessary pipe connection etc. complete.
460Providing and fixing Hand shower (health faucet) with 8mm dia. 1m long flexible tube having wall hook with approved make including necessary sockets/ union nut etc. complete as directed by Engineer in charge.
461Providing and fixing White glazed with bottle trap earthenware Wash Hand Basin of 55x40 cm size including cold water piller taps, brackets, rubber plugs and brass chain, stop tap, chromium plate bottle trap and necessary pipe connections including UPAC waste pipe and trap upto the outside face of the wall, making good the damaged surface, testing etc. complete.
462Providing and fixing C.P. BIB cock with wall flange of approved make including necessary sockets/ union nut etc. complete as directed by Engineer in charge.
463Providing and fixing white glazed urinal of size 710x460x300mm with sensotronic concealed type flushing valve for urinal with complete kit having fittings, inlet pipe with stop tap, brackets for fixing the cistern, 32mm diameter P.V.C. flush pipe with fitting and flushing arrangement including lead soil pipe, lead trap & soil pipe connection upto the outside face of wall etc complete.
464Providing and fixing C.P. Angular stop clock with wall flange of approved make continental including necessary sockets/union nut etc. complete.
465Providing and fixing PTMT liquid soap container 109 mm wide, 125 mm high and 112 mm distance from wall of standard shape with bracket of the same materials with snap fittings of approved quality and colour, weighing not less than 105 gms.
466Providing and fixing uplasticised PVC connection pipe with brass unions :
46745 cm length
46815 mm nominal bore
469Total SANITARY INSTALLATIONS
470INTERNAL SEWERAGE & DRAINAGE
471Supplying installation testing and commissoning of Hubless centrifugally cast iron pipes as per ISI 15905 equivalent to NECO inclusive of all necessary special fitting like bends, tees, and caps, "Y" bends for cleaning offsets, junctions, cowls, etc. lad under floor/fixed on walls and in pipe shafts etc. complete. The quoted rate should include lead and lifting charges to all levels, necessary scaffolding and supports like hanger supports grip bolts and CV sheet 304 grade clamps etc. with prior approval of concerned Superitending Engineer.
472100 mm dia
473Providing and fixing on walls/ ceiling/ floors, 32 mm dia. heavy grade having embossed as ISI Mark galvanised iron pipes weight of 3.89 Kg/meter with necessary fittings . remaking good the demolished portion and applying primer of anti-corrosive oil paint 2 coats Including necessary scaffolding and removing existing pipe line if necessary and conveying and stacking the same in PWD chowky or as directed etc. complete.
474Providing and fixing on walls/ ceiling/ floors, 40 mm dia. heavy grade having embossed as ISI Mark galvanised iron pipes weight of 4.49 Kg/meter with necessary fittings and remaking good the demolished portion and applying primer of anti-corrosive oil paint 2 coats Including necessary scaffolding and removing existing pipe line if necessary and conveying and stacking the same in PWD chowky or as directed etc. complete.
475Providing and fixing on walls/ ceiling/ floors, 50 mm dia heavy grade having embossed as ISI Mark galvanised iron pipes weight of 6.33 Kg/meter with necessary fittings.and remaking good the demolished portion and primer of anti corrossive oil paint 2 coats Including necessary scaffolding and removing existing pipe line if necessary and conveying and stacking the same in PWD chowky or as directed etc. complete.
476Providing and fixing 10cm C.I. Nahani Trap including C.I. grating bend and piece of C.I. pipe upto the outside face of the wall complete.
477Providing and fixing P.V.C. Rain water pipes of 110mm outer diameter and having wall thickness of 2.2 to 2.7 mm confirming to I.S. 13592- 1992 including proper rainwater receiving recess with P.V.C. plug, bend, necessary fittings, such as, offsets, shoes, inluding fixing the pipe on wall using approved wooden cleats projecting 25mm to 40mm from face of wall a fixing with clips of approved quality and number ,filing the joint using rubber gasket with solvent cement and properly resting the shoe of pipes on C.C. or masonry blocks, including necessary scaffolding and maintenance for 3 yrs for any leakages or dislocations of pipes. All the P.V.C. fittings and additional 2 piece socket clips shall be got approved from engineer in charge etc. complete.
478Providing and fixing to the inlet mouth of rain water pipe cast iron grating 15 cm diameter and weighing not less than 440 grams.
479Providing and fixing Ductile iron Man Hole Covers/ Strom Water Grating and Grating with frame of Various sizes, weight and types and load bearing capacity as per EN-124, equivalent NECO with prior approval of concerned Superitending Engineer.
480Total INTERNAL SEWERAGE & DRAINAGE
481INTERNAL WATER SUPPLY
482Providing and fixing on walls/ ceiling/ floor 15 mm dia. CPVC pipe with necessary fittings, remaking good the demolished portion etc. complete. Including removing existing pipe line if necessary and conveying and stacking the same in PWD chowky or as directed etc. complete.
483Providing and fixing on walls/ceiling/floor 20 mm dia. CPVC pipe with necessary fittings, remaking good the demolished portion etc. complete. Including removing existing pipe line if necessary and conveying and stacking the same in PWD chowky or as directed etc. complete.
484Providing and fixing on walls/ ceiling/ floor 25 mm dia. CPVC pipe with necessary fittings, remaking good the demolished portion etc. complete. Including removing existing pipe line if necessary and conveying and stacking the same in PWD chowky or as directed etc. complete.
485Providing and fixing on walls/ ceiling/ floor 32 mm dia. CPVC pipe with necessary fittings, remaking good the demolished portion etc. complete. Including removing existing pipe line if necessary and conveying and stacking the same in PWD chowky or as directed etc. complete.
486Providing and fixing on walls /ceiling/ floor 40 mm dia. CPVC pipe with necessary fittings, remaking good the demolished portion etc. complete. Including removing existing pipe line if necessary and conveying and stacking the same in PWD chowky or as directed etc. complete.
487Providing and fixing on walls/ ceiling/ floors, 25 mm dia. heavy grade having embossed as ISI Mark galvanised iron pipes weight of 3.01 Kg/meter with necessary fittings . remaking good the demolished portion and applying primer of anti-corrosive oil paint 2 coats Including necessary scaffolding and removing existing pipe line if necessary and conveying and stacking the same in PWD chowky or as directed etc. complete.
488Providing and fixing on walls/ ceiling/ floors, 40 mm dia. heavy grade having embossed as ISI Mark galvanised iron pipes weight of 4.49 Kg/meter with necessary fittings and remaking good the demolished portion and applying primer of anti-corrosive oil paint 2 coats Including necessary scaffolding and removing existing pipe line if necessary and conveying and stacking the same in PWD chowky or as directed etc. complete.
489Providing and fixing gun metal gate valve with C.I. wheel of approved quality (screwed end) :
49025 mm nominal bore
49132 mm nominal bore.
49240 mm nominal bore
493Providing and fixing ball valve (brass) of approved quality, High or low pressure, with plastic floats complete :
49425 mm nominal bore
49532 mm nominal bore
496Prividing and Fixing automatic "NO-Touch " electric hand-driers complete with all accessories & fittings. (Make: Jaquar Model No. HDR-SAP-M99ACS)
497Providing and fixing Water cooler with inbuilt RO and storage complete including fixing in position.
498Providing and fixing H.D.P container Syntex or alike one piece moulded water tank made out of low density polythyler and built corrugation including of delivery up to destination hoisting and fixing of accessories such as inlet, outlet overflow of all tanks capacity above 1000 to 20,000 litres.
499Total INTERNAL WATER SUPPLY
500TOTAL INTERNAL PLUMBING COST (RS.)
501PAVILION BUILDING , BOQ - CIVIL WORKS
502EARTH WORKS
503Excavation for foundation in earth, soil of all types, sand, gravel and soft murum, including removing the excavated material upto adistance of 50m. beyond the building area and stacking and spreading as directed, dewatering, preparing the bed for the foundation and necessary backfilling, ramming, watering including shoring and strutting etc. complete. (Lift upto 1.5 m.) By Mechanical Means.
504Excavation for foundation in earth, soils of all types, sand,gravel and soft murum, including removing the excavated material upto a distance of 50 metres beyond the building area and stacking and spreading as directed, dewatering, preparing the bed for the foundation and necessary back filling, ramming, watering including shoring and strutting etc. complete. (Lift from 1.5m to 3.0m)
505Excavation for foundation in Soft rock and old cement or lime masonry foundations including removing the excavated material upto a distance of 50 metres beyond the building area and stacking as directed, including dewatering, preparing the bed for the foundation and necessary back filling with available earth /murum, ramming, watering including shoring and strutting etc. complete (lift upto 1.5m)
506Excavating trenches of required width for pipes, cables, etc. including excavation for sockets, and dressing of sides, ramming of bottoms, depth upto 1.5m including getting out the excavated soil, and then returning the soil as required, in layers not exc
507All kinds of soil.
508Pipes, cables, etc. exceeding 80mm dia but not exceeding 300mm dia.
509Filling in plinth and floors withapprovedexcavated material in 15cm. to 20cm. layers including watering and compacting etc. complete.
510Disposal of excavated excess earth/Ordinary rock away from the site including conveyance of materials up to an average lead of 5KM away from the site, and correspondiong required lift, loading, unloading etc complete as directed by the Engineer-in-charge. (The quantity is net quantity of capacity of truck after deduction of 20% for looseness)(considering the maximum disposal location at 5 KM distance)
511Earth: By mechanical transport including loading, unloading and stacking. (Lead upto 5KM away from the site)
512Ordinary rock:By mechanical transport including loading, unloading and stacking. (Lead upto 5KM away from the site)
513Providing and filling in the foundation with sand of approved quality including watering, compacting etc. complete. (To be executed with prior approval of Superintending Engineer)
514Labour charges for removing grass, thorney shrubs, Jungli shrub, Kubabul and alike grass along roadside making the ground clean by showel and phavaras etc. complete.
515Providing preconstructional antitermite treatment as per I.S. 6313 (Part-II) by treating the top surface of plinth filling at the rate of 5 litres of emulsion concentrate at 1.0 percent ofclorophyrifosper square metre of surface area covering ten years guarantee on bond paper.
516Providing general pest control services to the building to control the nuisance of cockroaches, lizards, pin bores and other insects etc. with 4 operations in a year and monthly check up.
517TOTAL (Earth work)
518CONCRETEWORKS
519Providing and laying Cast in situ/Ready Mix cement concrete in M-10 of trap/ granite/ quartzite/ gneiss metal for foundation and bedding including bailing out water, formwork, laying/pumping, compacting, roughening them if special finish is to be provided, finishing if required and curing complete, with fully automatic micro processor based PLC with SCADA enabled reversible Drum Type mixer/concrete Batch mix plant (Pan mixer) etc. complete.With natural sand/V.S.I. quality Artificial Sand
520Providing and laying Cast in situ/Ready Mixcement concrete in M15 of trap/ granite/quartzite/gneiss metal for steps including steel centering, plywood/steel formwork, laying/pumping, compacting, roughening them if special finish is to be provided, finishing uneven and honeycombed surface and curing etc. complete. The Cement Mortar 1:3 plaster is considered for rendering uneven and honeycombed surface, only. Newly laid concrete shall be covered by gunny bag, plastic, tarpaulin etc. (Wooden centering will not be allowed.),with fully automatic micro processor based PLC with SCADA enabled reversible Drum Type mixer/concrete Batch mix plant (Pan mixer) etc. complete. With natural sand/V.S.I. quality Artificial Sand
521Providing and laying damp proof course 50 mm thick in M20 cement concrete layer and bitumen / using cement with waterproofing compound curing, formwork etc. complete.
522Providing and applying Bitumen VG30/VG40 layer at 2 kg. per square meter over the terrace, structural slab including cleaning the surface for waterproofing as directed complete
523Making plinth protection 50mm thick of cement concrete 1:3:6 (1 cement : 3 coarse sand (zone - III) : 6 graded stone aggregate 20 mm nominal size) over 75mm thick bed of dry brick ballast 40 mm nominal size, well rammed and consolidated and grouted with fine sand, including necessary excavation, levelling & dressing & finishing the top smooth.
524TOTAL (CONCRETEWORKS)
525REINFORCED CEMENT CONCRETE WORK
526Providing and laying Cast in situ/Ready Mix cement concrete M-25 of trap / granite /quartzite/ gneiss metal for R.C.C. work in foundations like raft, strip foundations, grillage and footings of R.C.C. columns and steel stanchions etc. columns as per detailed designs and drawing or as directed including centering, formwork, cover blocks laying/pumping, compaction finishing the formed surfaces with cement mortar 1:3 of sufficient minimum thickness to give a smooth and even surface or roughening if special finish is to be provided and curing etc. complete. (Excluding reinforcement and structural steel). with fully automatic micro processor based PLC with SCADA enabled reversible Drum Type mixer/ concrete Batch mix plant (Pan mixer) etc. complete. With natural sand/V.S.I. quality Artificial Sand
527Providing and laying Cast in situ/Ready Mix cement concrete M-25 of trap / granite /quartzite/ gneiss metal for R.C.C. columns as per detailed designs and drawings or as directed including centering, formwork, cover blocks compacting and roughening if special finish is to be provided and curing etc. complete. (Excluding reinforcement and structural steel).with fully automatic micro processor based PLC with SCADA enabled reversible Drum Type mixer/ concrete Batch mix plant (Pan mixer) etc. complete. With natural sand/V.S.I. quality Artificial Sand
528Providing and laying Cast in situ/Ready Mix cement concrete in M-25 of trap/ granite/ quartzite/ gneiss metal for R.C.C. beams and lintels as per detailed designs and drawings or as directed including centering, formwork, cover blocks, laying/pumping, compactionand roughening the surface if special finish is to be provided and curing etc. complete. (Excluding reinforcement and structural steel).with fully automatic micro processor based PLC with SCADA enabled reversible Drum Type mixer/ concrete Batch mix plant (Pan mixer) etc. complete. With natural sand/V.S.I. quality Artificial Sand
529Providing and laying Cast in situ/Ready Mix cement concrete M-25 of trap/ granite / quartzite/ gneiss metal for R.C.C. slabs and landingsas per detailed designs and drawings including centering, formwork, cover blocks, compaction, finishing the formed surfaces with cement mortar 1:3 of sufficient minimum thickness to give a smooth and even surface or roughening if special finish is to be provided and curing etc. complete.(Excluding reinforcement and structural steel).with fully automatic micro processor based PLC with SCADA enabled reversible Drum Type mixer/ concrete Batch mix plant (Pan mixer) etc. complete. With natural sand/V.S.I. quality Artificial Sand
530Providing and laying Cast in situ/Ready Mix cement concrete inM-25 of trap / quartzite /granite /gneiss metal for R.C.C. Waist slab, and steps of staircases as per detailed design and drawings or as directed including steel centering, plywood/ steel formwork, steel props, laying/pumping, compaction, finishing uneven and honeycombed surface with C.M. 1:3 of sufficient minimum thickness to give a smooth and even surface or roughening the surface if special finish is to be provided and curing etc. complete. (Excluding einforcement, including cover block).(Newly laid concrete shall be covered by gunny bag, plastic, tarpaulin etc.) with fully automatic micro processor based PLC with SCADA enabled reversible Drum Type mixer/ concrete Batch mix plant (Pan mixer) etc. complete. With natural sand/V.S.I. quality Artificial Sand
531Providing and fixing in position TMT - FE - 500 bar reinforcement of various diameters for R.C.C. pile caps, footings, foundations, slabs, beams columns, canopies, staircase, newels, chajjas, lintels pardis, copings, fins, arches etc. as per detailed designs, drawings and schedules. including cutting, bending, hooking the bars, binding with wires or tack welding and supporting as required complete.
532TOTAL (REINFORCED CEMENT CONCRETE WORK)
533BRICK WORK
534Providing second class Burnt Brick masonry with conventional/ I.S. type bricks in cement mortar 1:6 in foundations and plinth of inner walls/ in plinth external walls including bailing out water manually , striking joints on unexposed faces, raking out joints on exposed faces and watering etc. Complete.
535Providing second class Burnt Brick masonry with conventional/ I.S. type bricks in cement mortar 1:6 in superstructure including striking joints, raking out joints, watering and scaffolding etc. Complete
536Providing second class Burnt Brick masonry with conventional/ I.S. type bricks in cement mortar 1:4 in half brick thick wall including mild steel longitudinal reinforcement of 2 bars of 6 mm diameter / 2 hoop iron strips 25 mm X 1.6 mm placedat every third course, properly bent and bonded at ends scaffolding, racking out joints and watering etc. complete.
537Brick edging 7cm wide 11.4 cm deep to plinth protection with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 including grouting with cement mortar 1:4 (1 cement : 4 fine sand).
538TOTAL (BRICK WORK)
539MARBLE & GRANITE WORK
540Providing and fixing machine cut mirror polished 18 mm to 20 mm thick telephone black / Amba White / Cat bary brown / RBI red / Ocean Brown granite stone partition with rounding the edgesetc. complete. One side polish
541Extra for providing opening of required size & shape for wash basins/ kitchen sink in kitchen platform, vanity counters and similar location in marble/Granite/Stone work including necessary holes for pillar taps etc. including rubbing and polishing of cut edge etc. complete.
542TOTAL (MARBLE & GRANITE WORK)
543STEEL WORK
544Providing and fabricating structural steel work in rolled sections like joists, channels, angles, tees etc. as per detailed design and drawings or as directed including cutting, fabricating, hoisting, erecting, fixing in position making riveted / bolted /welded connections without connecting plates, braces etc. and including one coat of anticorrosive paint and over it two coats of oil painting of approved quality and shade etc. complete.
545Providing and Fixing mat finish stainless steel (of 302 grade ) railing with toppipe of 50 mm dia. and vertical pipe of 38 mm dia at 0.60 m c/c or as required and horizontal pipes of 25 mm dia in three rows, all pipes of 2 mm thick including buffing,fabricating fixtures and fastening including pipe base of appropriate diameter and ball base of 75 mm dia above newel post of 75 mm diameter etc. complete (Prior approval of sample and brand by Ex.Engineer is necessary before use)
546TOTAL (STEEL WORK)
547FLOORING WORK
548Providing and laying cement concrete flooring 40 mm thick with M15 cement concrete laid to proper level and slope in alternate bays including compaction, filling joints, marking lines to give the appearance of tiles of 30 cm x 30 cm or other size laid diagonally /square etc finishing smooth (with extra cement) in any colour as directed and curing etc.complete. With Natural Sand
549Providing and laying machine cut machine Polished Kota stone flooring 25mm to 30mm thick and required width in plain/ diamond pattern on bed of 1:6 C. M. including cement float, filling joints with neat cement slurry, curing, polishing and cleaningetc. complete.
550Providing and fixing in required position skirting or dado of polished Kotah Stone slab 25mm to 30mm thick fixed on base on plaster of cement mortar 1:4 including cement float, filling joints with cement slurry, curing rubbing, polishing and cleaning complete.
551Providing and laying machine cut machine polished machine cut Kota stone slabs 20 to 25 mm thick for treads and risers of steps and staircases, with rounded nosing for the treads on a bed of 1:4 cement mortar including cement float, filling joints with neat cement slurry, curing, polishing and cleaning etc. complete.
552Providing and laying vitrified mirror / glossy finish tiles decorative typehaving size 590 mm to 605 mm x 590 mm to 605 mm of 8 to 10 mm thickness and confirming to IS. 15622-2006 ( group Bla) of approved make, shade and pattern for flooring in required position laid on a bed of 1:4 cement mortar including neat cement float, filling joints, curing and clearingetc. complete. a) Flooring
553Providing and laying vitrified mirror / glossy finish tiles having size 590 mm to 605 mm x 590 mm to 605 mm of 8 to 10 mm thickness and confirming to IS. 15622-2006 ( group Bla) of approved make, shade and pattern for flooring in required position laid on a bed of 1:4 cement mortar including neat cement float, filling joints, curing and clearingetc. complete.b) Skirting
554Providing and laying ceramic tileshaving size 30 cm. x 45 cm. confirming to corresponding I.S. for dado and skirting in required position with readymade adhesive mortar of approved quality on plaster of 1:2 cement mortar including joint filling with white/ colour cement slurry cleaning curing etc. complete.
555Providing and laying Antiskid Ceramic tiles of approved qualityof size 30 cm x 30 cm and confirming to IS 15622-2006 (Group-B IIA) for antiskid flooring in required position laid on a bed of 1:4 cement mortar including cement float, filling joint with cement slurry cleaning curing etc. complete.
556TOTAL (FLOORING WORK)
557ROOFING
558Providing and fixing P.V.C. Rain water pipes of 110mm outer diameter and having wall thickness of 2.2 to 2.7 mm confirming to I.S. 13592-1992 including proper rainwater receiving recess with P.V.C. plug, bend, necessary fittings, such as, offsets, shoes, inluding fixing the pipe on wall using approved wooden cleats projecting 25mm to 40mm from face of wall a fixing with clips of approved quality and number ,filing the joint using rubber gasket with solvent cement and properly resting the shoe of pipes on C.C. or masonry blocks, including necessary scaffolding and maintenance for 3 yrs for any leakages or dislocations of pipes. All the P.V.C. fittings and additional 2 piece socket clips shall be got approved from engineer in charge etc. complete. (The contractor shall give 3 yrs guarantee bond for payment)
559Providing and laying pressed clay tiles (as per approved pattern 20 mm nominal thickness of approved size) on roofs jointed with cement mortar 1:4 (1 cement : 4 coarse sand) mixed with 2% integral water proofing compound, laid over a bed of 20 mm thick cement mortar 1:4 (1 cement : 4 coarse sand) and finished neat complete.
560Providing and fixing in position Gypsum board false ceiling with 12.5mm thick Gypsum boards, screwed /fixed to the under structure of suspended G.I.Grid constructed and suspended from the main ceiling consisting of ceiling sections of size 25x50mm maximum center to center distance of 600 milimetre perimeter channel and intermediate channels at maximum center to center distance 1200 milimetre galvanized grid should be fixed to reinforced cement concrete slab. The gypsum board should be fixed to galvanized iron grid with necessary screws. The boards should be taped and filled from under side to give smooth, seamless ceiling. The rate should include necessary additional ceiling sections and intermediate channels. Additional intermediate channels should be fixed to strap hangers for additional support to prevents trap pin gate very 1200 milimetre item to be completed in all respect including necessary sleeves for ducts finishing of joints cutouts, painting includinglabour,material,liftsetc.all complete.
561Providing and Fixing of GI Lay in Plain metal ceiling consisting of 600x600mm Lay in tiles of pre coated galvanized steel in 0.5 mm thickness in Global white color tile to be laid ongrid systems with 15mm wide T - section flanges color white having rotary stitching on the Main Runner, 1200 mm and 600 mm Cross Tees.Providing and Fixing of GI Lay in Plain metal ceiling consisting of 600x600mm Lay in tiles of pre coated galvanized steel in 0.5 mm thickness in Global white color tile to be laid on grid systems with 15mm wide T - section flanges color white having rotary stitching on the Main Runner, 1200 mm and 600 mm Cross Tees.products approved as per GRIHA and BS 476 etc. complete.
562TOTAL (ROOFING)
563FINISHING WORK
564Providing internal cement plaster 12mm thick in single coat in cement mortar 1:4 without neeru finish to concrete or brick surfaces, in all positions including scaffolding and curing etc. complete.
565Providing rough cast cement plaster externally in two coats to concrete,brick or stone masonry surfaces in all positions with base coat of 12 to 15mm thick in C.M.1:4 and rough cast treatment 12mm thick in proportion 1:11/2:3 including scaffolding and fourteen days curing complete.
566Labour charges for providing groove in external plaster having width and spaced as directed by engineer incharge etc. complete.
567Providing internal cement plaster 6 mm thick in a single coat in cement mortar 1:3 without neeru finish to concrete surface in all positions including scaffolding and curing etc. complete.
568Providing and fixing chicken mesh of 22 gauge, with about 30 cm. width at the junction of R.C.C members and brick work, of approved quality including fixing mesh in position by necessary drilling in concrete /B.B.masonry and or tying by binding wire etc. complete.
569Providing and applying washable oil-bound distemper of approved colour and shade to old and new surfaces in two coats including scaffolding, preparing the surfaces. (excluding the primer coat.) etc. complete.
570Providing and applying priming coat on concrete/ masonary/ Asbestos Cement plastered surfaces including scaffolding if necessary, preparing the surface by thoroughly cleaning oil, grease, dirt and other foreign matter and sand papering as required etc. complete.
571Providing and applying two coats of textured synthetic paint of approved shade and quality and one coat of primer before applying textured paint including scaffolding if necessary preparing surface by thoroughly cleaning oil, grease, dirt and other materials as required, etc. complete.
572Providing and applying plastic emulsion paint of approved quality, colour and shade to old and new surfaces in two coats including scaffolding, preparing the surface. (excluding the primer coat)etc. complete.
573Providing and applying Two coats of wall care Putty of 2mm thickness for plastered surface and 5-6mm thickness finished concrete surface to Ceiling and Walls to prepare surface even and smooth of Brands BIRLA WHITE, BERGER, BISION, J.K., make, etc complete.a) For plastered walls/ceiling 2mm
574Providing and applying two coats of synthetic enamel paint of approved colour to new /old structural steel work and wood work in buildings, including scaffolding if necessary, cleaning and preparing the surface (excluding primer coat) etc. complete.
575TOTAL (FINISHING WORK)
576ALUMINIUM WORK
577Providing and fixing in position aluminium partly openable and partly fixed window of any size as per detailed drawing and as directed by Engineerincharge with all necessary alluminium sections including necessary fixtures and fastening with 5 mm thick float glass etc. complete. b) With powder coating Note While arriving at the rate of item of item weight at 6.90 kg/Sqm is considered.
578Providing and fixing in position, Double shuttered aluminium extruded powder coated openable door of specified size with aluminium door frame of powder coated section 101.60 x 44.75mm , 3.18 mm thick and shutter comprising of powder coated section having bottom and lock rail of size 150 mm x 44.5 mm x 3.00 mm thick top rails 47.62 x 44.45 mm x 3.00 mm thick , vertical style 47.62 x 44.45 mm, 3.00 mm thick and for shutter plain glass panes 5 mm thick for top panels and 12mm thick both side laminated phenol bonded particle board panels for bottom panels etc. , I.S.I. mark , heavy duty, Hydraulic floor spring of 150 kg capacity , having heavy duty concealed lock, necessary beading, glazing clips, PVC gaskets, 250mm length aluminium tower bolts, 150mm dia. pad handle, etc. as per detailed design and drawing or as directed by engineer in charge including all materials , labours, and equipment etc.complete
579Providing and fixing in position, Single shuttered aluminium extruded powder coated openable door of overall size 0.9mx2.4m with aluminium door frame of powder coated section 101.60 x 44.75mm , 3.18 mm thick and shutter comprising of powder coated section having bottom and lock rail of size 150 mm x 44.5 mm x 3.00 mm thick top rails 47.62 x 44.45 mm x 3.00 mm thick , vertical style 47.62 x 44.45 mm, 3.00 mm thick and for shutter plain glass panes 5 mm thick for top panels and 12mm thick both side laminated phenol bonded particle board panels for bottom panels etc. , I.S.I. mark , heavy duty, Hydraulic floor spring of 150 kg capacity , having heavy duty concealed lock, necessary beading, glazing clips, PVC gaskets, 250mm length aluminium tower bolts, 150mm dia. pad handle, etc. as per detailed design and drawing or as directed by engineer in charge including all materials , labours, and equipment etc.complete
580Providing and supplying aluminium extruded tubular and other aluminium sections as per the architectural drawings and approved shop drawings , the aluminium quality as per grade 6063 T5 or T6 as per BS 1474, including super durable powder coating of 60-80 microns conforming to AAMA 2604 of required colour and shade as approved by the Engineer-in-Charge. ( The item includes cost of material such as cleats, sleeves, fasteners screws etc as desired. necessary for fabrication of extruded aluminium frame work. Nothing extra shall be paid on this account). The weight of aluminium extruded section shall be taken for purpose of payment.
581Designing, fabricating, testing, protection, installing and fixing in position semi (grid) unitized system of structural/ curtain wall glazing (with open joints) for linear as well as curvilinear portions of the building for all heights and all levels, including :
582a) Structural analysis & design and preparation of shop drawings for the specified design loads conforming to IS 875 part III (the system must passed the proof test at 1.5 times design wind pressure without any failure), including functional design of the aluminum sections for fixing glazing panels of various thicknesses, aluminium cleats, sleeves and splice plates etc. gaskets, screws, toggles, nuts, bolts, clamps etc., structural and weather silicone sealants, flashings, fire stop (barrier)-cum-smoke seals, microwave cured EPDM gaskets for water tightness, pressure equalization & drainage and protection against fire hazard including:
583b) Fabricating and supplying serrated M.S. hot dip galvanized / Aluminium alloy of 6005 T5 brackets of required sizes, sections and profiles etc. to accommodate 3 Dimensional movement for achieving perfect verticality and fixing structural glazing system rigidly to the RCC/ masonry/structural steel framework of building structure using stainless steel anchor fasteners/ bolts, nylon separator to prevent bimetallic contacts with nuts and washers etc. of stainless steel grade 316, of the required capacity and in required numbers..
584c) Providing and filling, two part pump filled, structural silicone sealant and one part weather silicone sealant compatible with the structural silicone sealant of required bite size in a clean and controlled factory / work shop environment , including double sided spacer tape, setting blocks and backer rod, all of approved grade, brand and manufacture, as per the approved sealant design, within and all around the perimeter for holding glass
585d) Providing and fixing in position flashings of solid aluminium sheet 1 mm thick and of sizes, shapes and profiles, as required as per the site conditions, to seal the gap between the building structure and all its interfaces with curtain glazing to make it watertight.
586e) Making provision for drainage of moisture/ water that enters the curtain glazing system to make it watertight, by incorporating principles of pressure equalization, providing suitable gutter profiles at bottom (if required), making necessary holes of required sizes and of required numbers etc. complete. This item includes cost of all inputs of designing, labour for fabricating and installation of aluminium grid, installation of glazed units, T&P, scaffolding and other incidental charges including wastages etc., enabling temporary structures and services, cranes or cradles etc. as described above and as specified. The item includes the cost of getting all the structural and functionaldesign including shop drawings checked by a structural designer, dully approved by Engineer-in-charge.
587The item also includes the cost of all mock ups at site, cost of all samples of the individual components for testing in an approved laboratory, field tests on the assembled working structural glazing as specified, cleaning and protection till the handing over of the building for occupation. In the end, the Contractor shall provide a water tight structural glazing having all the performance characteristics etc. all complete as required, as per the Architectural drawings, as per item description, as specified, as per the approved shop drawings and as directed by the Engineer in-Charge.
588Note:- 1. The cost of providing extruded aluminium frames, shadow boxes, extruded aluminium section capping for fixing in the grooves of the curtain glazing and vermin proof stainless steel wire mesh shall be paid for separately under relevant items under this subhead. However, for the purpose of payment, only the actual area of structural/ curtain wall glazing (including width of grooves ) on the external face shall be measured in sqm. up to two decimal places.
589Providing, assembling and supplying vision glass panels (IGUs) comprising of hermetically-sealed 6-12- 6 mm insulated glass (double glazed) vision panel units of size and shape asrequired and specified, comprising of an outer heat strengthened (as approved) glass 6mm thick, of approved colour and shade with reflective soft coating on surface # 2 of approved colour and shade, an inner heat strengthened (as approved) clear float glass 6mm thick, spacer tube 12mm wide, desiccants, including primary seal and secondary seal (structural silicone sealant) etc. all complete for the required performances, as per the Architectural drawings, as per the approved shop drawings, as specified and as directed by the Engineer-in-Charge. The IGUs shall be assembled in the factory/ workshop of the glass processor. (Payment for fixing of IGU Panels in the curtain glazing is included in cost of item No.1.8.16 above). For payment, only the actual area of glass on face # 1 of the glass panels (excluding the areas of the grooves and weather silicone sealant) provided and fixed in position, shall be measured in sqm. (To be fixed on extruded aluminium sections. and cost of aluminium sections to be paid in relevant item)
590(i) Coloured tinted float glass 6mm thick Heat Strengthened substrate with reflective soft coating on face # 2, + 12mm Airgap + 6mm Heat Strengthened clear Glass of approved make having properties as visible Light transmittance (VLT) of 25 to 35 %, Light reflection internal 10 to 15%, light reflection external 10 to 20 %, shading coefficient (0.25- 0.28) and U value of 3.0 to 3.3 W/m2 degree K etc.
591TOTAL (ALUMINIUM WORK)
592WATER PROOFING
593Providing cement based water proofing treatment to terraces (Indian water proofing or alike) with brick bats laid in required slope to drain the water for any span after cleaning the base surface. Applying a coat of cement slurry admixed with approved water proofing compound and laying the brick bats on bottom layer in C.M.1:5 admixed with approved water proofing compound filling up to half depth of brick bats, curing this layer for 3 days, applying cement slurry over this layer joints of brick bats with C.M.1:3 admixed with approved water proofing compound and finally top finishing with average 20 mm. thick layers of same mortar added with jute fiber at 1 Kg per bag including finishing the surface smooth with cement slurry admixed with approved water proofing compound. Marking finished surface with false squares of 300mm x 300 mm. making the junctions at the parapet rounded and tapered top for required height, with drip mould at the junction of plaster and parapet and curing and covering 10 years Guarantee against leakproofness on Court fee stamp paper of Rs. 500/- including ponding test etc. complete.
594TOTAL (WATER PROOFING)
595TOTAL PAVILION BUILDINGCIVIL WORKS
596TOTAL PART-A PAVILION BUILDING & CRICKET GROUND
597PART-B KITCHEN & DINING HALL
598CIVIL WORKS
599EARTH WORKS
600Excavation for foundation in earth, soil of all types, sand, gravel and soft murum, including removing the excavated material upto adistance of 50m. beyond the building area and stacking and spreading as directed, dewatering, preparing the bed for the foundation and necessary backfilling, ramming, watering including shoring and strutting etc. complete. (Lift upto 1.5 m.) By Mechanical Means.
601Excavation for foundation in earth, soils of all types, sand,gravel and soft murum, including removing the excavated material upto a distance of 50 metres beyond the building area and stacking and spreading as directed, dewatering, preparing the bed for the foundation and necessary back filling, ramming, watering including shoring and strutting etc. complete. (Lift from 1.5m to 3.0m)
602Excavation for foundation in Soft rock and old cement or lime masonry foundations including removing the excavated material upto a distance of 50 metres beyond the building area and stacking as directed, including dewatering, preparing the bed for the foundation and necessary back filling with available earth /murum, ramming, watering including shoring and strutting etc. complete (lift upto 1.5m)
603Excavating trenches of required width for pipes, cables, etc. including excavation for sockets, and dressing of sides, ramming of bottoms, depth upto 1.5m including getting out the excavated soil, and then returning the soil as required, in layers not exc
604All kinds of soil.
605Pipes, cables, etc. exceeding 80mm dia but not exceeding 300mm dia.
606Filling in plinth and floors withapprovedexcavated material in 15cm. to 20cm. layers including watering and compacting etc. complete.
607Filling in plinth and floors with contractorsmaterial/brought from outside and approved by Engineer inchargein layers of 15 cmto 20 cm including watering and compaction etc. complete.
608Disposal of excavated excess earth/Ordinary rock away from the site including conveyance of materials up to an average lead of 5KM away from the site, and correspondiong required lift, loading, unloading etc complete as directed by the Engineer-in-charge. (The quantity is net quantity of capacity of truck after deduction of 20% for looseness)(considering the maximum disposal location at 5 KM distance)
609Ordinary rock:By mechanical transport including loading, unloading and stacking. (Lead upto 5KM away from the site)
610Providing and filling in the foundation with sand of approved quality including watering, compacting etc. complete. (To be executed with prior approval of Superintending Engineer)
611Labour charges for removing grass, thorney shrubs, Jungli shrub, Kubabul and alike grass along roadside making the ground clean by showel and phavaras etc. complete.
612Providing preconstructional antitermite treatment as per I.S. 6313 (Part-II) by treating the top surface of plinth filling at the rate of 5 litres of emulsion concentrate at 1.0 percent ofclorophyrifosper square metre of surface area covering ten years guarantee on bond paper.
613Providing general pest control services to the building to control the nuisance of cockroaches, lizards, pin bores and other insects etc. with 4 operations in a year and monthly check up.
614TOTALEARTH WORKS
615CONCRETEWORKS
616Providing and laying Cast in situ/Ready Mix cement concrete in M-10 of trap/ granite/ quartzite/ gneiss metal for foundation and bedding including bailing out water, formwork, laying/pumping, compacting, roughening them if special finish is to be provided, finishing if required and curing complete, with fully automatic micro processor based PLC with SCADA enabled reversible Drum Type mixer/concrete Batch mix plant (Pan mixer) etc. complete.With natural sand/V.S.I. quality Artificial Sand
617Providing and laying Cast in situ/Ready Mixcement concrete in M15 of trap/ granite/quartzite/gneiss metal for steps including steel centering, plywood/steel formwork, laying/pumping, compacting, roughening them if special finish is to be provided, finishing uneven and honeycombed surface and curing etc. complete. The Cement Mortar 1:3 plaster is considered for rendering uneven and honeycombed surface, only. Newly laid concrete shall be covered by gunny bag, plastic, tarpaulin etc. (Wooden centering will not be allowed.),with fully automatic micro processor based PLC with SCADA enabled reversible Drum Type mixer/concrete Batch mix plant (Pan mixer) etc. complete. With natural sand/V.S.I. quality Artificial Sand
618Providing and laying damp proof course 50 mm thick in M20 cement concrete layer and bitumen / using cement with waterproofing compound curing, formwork etc. complete.
619Providing and applying Bitumen VG30/VG40 layer at 2 kg. per square meter over the terrace, structural slab including cleaning the surface for waterproofing as directed complete
620Making plinth protection 50mm thick of cement concrete 1:3:6 (1 cement : 3 coarse sand (zone - III) : 6 graded stone aggregate 20 mm nominal size) over 75mm thick bed of dry brick ballast 40 mm nominal size, well rammed and consolidated and grouted with fine sand, including necessary excavation, levelling & dressing & finishing the top smooth.
621TOTAL CONCRETE WORK
622REINFORCED CEMENT CONCRETE WORK
623Providing and laying Cast in situ/Ready Mix cement concrete M-30 of trap / granite /quartzite/ gneiss metal for R.C.C. work in foundations like raft, strip foundations, grillage and footings of R.C.C. columns and steel stanchions etc. columns as per detailed designs and drawing or as directed including centering, formwork, cover blocks laying/pumping, compaction finishing the formed surfaces with cement mortar 1:3 of sufficient minimum thickness to give a smooth and even surface or roughening if special finish is to be provided and curing etc. complete. (Excluding reinforcement and structural steel). with fully automatic micro processor based PLC with SCADA enabled reversible Drum Type mixer/ concrete Batch mix plant (Pan mixer) etc. complete. With natural sand/V.S.I. quality Artificial Sand
624Providing and laying Cast in situ/Ready Mix cement concrete M-25 of trap / granite /quartzite/ gneiss metal for R.C.C. columns as per detailed designs and drawings or as directed including centering, formwork, cover blocks compacting and roughening if special finish is to be provided and curing etc. complete. (Excluding reinforcement and structural steel).with fully automatic micro processor based PLC with SCADA enabled reversible Drum Type mixer/ concrete Batch mix plant (Pan mixer) etc. complete. With natural sand/V.S.I. quality Artificial Sand
625Providing and laying Cast in situ/Ready Mix cement concrete in M-25 of trap/ granite/ quartzite/ gneiss metal for R.C.C. beams and lintels as per detailed designs and drawings or as directed including centering, formwork, cover blocks, laying/pumping, compactionand roughening the surface if special finish is to be provided and curing etc. complete. (Excluding reinforcement and structural steel).with fully automatic micro processor based PLC with SCADA enabled reversible Drum Type mixer/ concrete Batch mix plant (Pan mixer) etc. complete. With natural sand/V.S.I. quality Artificial Sand
626Providing and laying Cast in situ/Ready Mix cement concrete M-25 of trap/ granite / quartzite/ gneiss metal for R.C.C. slabs and landingsas per detailed designs and drawings including centering, formwork, cover blocks, compaction, finishing the formed surfaces with cement mortar 1:3 of sufficient minimum thickness to give a smooth and even surface or roughening if special finish is to be provided and curing etc. complete.(Excluding reinforcement and structural steel).with fully automatic micro processor based PLC with SCADA enabled reversible Drum Type mixer/ concrete Batch mix plant (Pan mixer) etc. complete. With natural sand/V.S.I. quality Artificial Sand
627Providing and laying Cast in situ/Ready Mixcement concrete M-25 of trap/ granite/ quartzite/ gneiss metal for R.C.C. chajja as per detailed design and drawings including centering, formwork, cover blocks, laying/pumping, compacting and roughening the surface if special finish is to be provided and curing complete. (Excluding reinforcement and structural steel). with fully automatic micro processor based PLC with SCADAenabled reversible Drum Type mixer/ concrete Batch mix plant (Pan mixer) etc. complete. With natural sand/V.S.I. quality Artificial Sand
628Providing and fixing in position TMT - FE - 500 bar reinforcement of various diameters for R.C.C. pile caps, footings, foundations, slabs, beams columns, canopies, staircase, newels, chajjas, lintels pardis, copings, fins, arches etc. as per detailed designs, drawings and schedules. including cutting, bending, hooking the bars, binding with wires or tack welding and supporting as required complete.
629TOTAL REINFORCED CEMENT CONCRETE WORK
630BRICK WORK
631Providing second class Burnt Brick masonry with conventional/ I.S. type bricks in cement mortar 1:6 in foundations and plinth of inner walls/ in plinth external walls including bailing out water manually , striking joints on unexposed faces, raking out joints on exposed faces and watering etc. Complete.
632Providing second class Burnt Brick masonry with conventional/ I.S. type bricks in cement mortar 1:6 in superstructure including striking joints, raking out joints, watering and scaffolding etc. Complete
633Providing second class Burnt Brick masonry with conventional/ I.S. type bricks in cement mortar 1:4 in half brick thick wall including mild steel longitudinal reinforcement of 2 bars of 6 mm diameter / 2 hoop iron strips 25 mm X 1.6 mm placedat every third course, properly bent and bonded at ends scaffolding, racking out joints and watering etc. complete.
634Brick edging 7cm wide 11.4 cm deep to plinth protection with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 including grouting with cement mortar 1:4 (1 cement : 4 fine sand).
635TOTAL BRICK WORK
636MARBLE & GRANITE WORK
637Providing and fixing machine cut mirror polished 18 mm to 20 mm thick telephone black / Amba White / Cat bary brown / RBI red / Ocean Brown granite stone partition with rounding the edgesetc. complete. One side polish
638Extra for providing opening of required size & shape for wash basins/ kitchen sink in kitchen platform, vanity counters and similar location in marble/Granite/Stone work including necessary holes for pillar taps etc. including rubbing and polishing of cut edge etc. complete.
639TOTAL MARBLE & GRANITE WORK
640STEEL WORK
641Providing and fixing rolling shutter fabricated from steel laths of minimum thickness 0.9 mm with lock plate of 3.15 mm thickness reinforced with 35 x 35 x 5 mm angle section fitted with sliding bolts and handles for both sides, deep M.S. channel section of depth and thickness not less than 65 mm and 3.15 mm respectively with hold fast arrangements, M.S. Bracket plate 300 x 300 x 3.15 mm minimum size and shape with square bar, suspension shaft of minimum 32 mm diameter, hood cover of M.S. sheet not less than 0.9 mm thickness and of any size at top and safety devices including mechanical gear operation arrangement consisting of worm gear wheels and worms of high grade cast iron or mild steel and one coat of red lead primer etc. complete. (I.S. 62481979) (With mechanical gear)
642Providing and fabricating structural steel work in rolled sections like joists, channels, angles, tees etc. as per detailed design and drawings or as directed including cutting, fabricating, hoisting, erecting, fixing in position making riveted / bolted /welded connections without connecting plates, braces etc. and including one coat of anticorrosive paint and over it two coats of oil painting of approved quality and shade etc. complete.
643Providing structural steel work in trusses, other similar trussed purlins and members with all bracing, gusset plates etc. as per detailed designs and drawings or as directed including cutting, fabricating, hoisting, erecting fixing in position, Making riveted/ bolted/ welded connection and one coat of anticorrosive paint and over it 2 coats of oil painting approved quality and shade etc. complete.
644Providing and Fixing mat finish stainless steel (of 302 grade ) railing with toppipe of 50 mm dia. and vertical pipe of 38 mm dia at 0.60 m c/c or as required and horizontal pipes of 25 mm dia in three rows, all pipes of 2 mm thick including buffing,fabricating fixtures and fastening including pipe base of appropriate diameter and ball base of 75 mm dia above newel post of 75 mm diameter etc. complete (Prior approval of sample and brand by Ex.Engineer is necessary before use)
645TOTAL STEEL WORK
646FLOORING WORK
647Providing and laying cement concrete flooring 40 mm thick with M15 cement concrete laid to proper level and slope in alternate bays including compaction, filling joints, marking lines to give the appearance of tiles of 30 cm x 30 cm or other size laid diagonally /square etc finishing smooth (with extra cement) in any colour as directed and curing etc.complete. With Natural Sand
648Providing and laying chequered tiles of approved qualityof size 30 cm x 30 cm, confirming to corresponding I.S. for flooring in required position laid on a bed of 1:4 cement mortar including cement float, filling joint with cement slurry cleaning curing etc. complete.
649Providing and laying machine cut machine Polished Kota stone flooring 25mm to 30mm thick and required width in plain/ diamond pattern on bed of 1:6 C. M. including cement float, filling joints with neat cement slurry, curing, polishing and cleaningetc. complete.
650Providing and fixing in required position skirting or dado of polished Kotah Stone slab 25mm to 30mm thick fixed on base on plaster of cement mortar 1:4 including cement float, filling joints with cement slurry, curing rubbing, polishing and cleaning complete.
651Providing and laying machine cut machine polished machine cut Kota stone slabs 20 to 25 mm thick for treads and risers of steps and staircases, with rounded nosing for the treads on a bed of 1:4 cement mortar including cement float, filling joints with neat cement slurry, curing, polishing and cleaning etc. complete.
652Providing and laying vitrified mirror / glossy finish tiles decorative typehaving size 590 mm to 605 mm x 590 mm to 605 mm of 8 to 10 mm thickness and confirming to IS. 15622-2006 ( group Bla) of approved make, shade and pattern for flooring in required position laid on a bed of 1:4 cement mortar including neat cement float, filling joints, curing and clearingetc. complete. a) Flooring
653Providing and laying vitrified mirror / glossy finish tiles having size 590 mm to 605 mm x 590 mm to 605 mm of 8 to 10 mm thickness and confirming to IS. 15622-2006 ( group Bla) of approved make, shade and pattern for flooring in required position laid on a bed of 1:4 cement mortar including neat cement float, filling joints, curing and clearingetc. complete.b) Skirting
654Providing and laying ceramic tileshaving size 30 cm. x 45 cm. confirming to corresponding I.S. for dado and skirting in required position with readymade adhesive mortar of approved quality on plaster of 1:2 cement mortar including joint filling with white/ colour cement slurry cleaning curing etc. complete.
655TOTAL FLOORING WORK
656ROOFING
657Providing and fixing plain zinc sheeting of 0.80 mm thick (22 B.W.G.) over the ridge hip or valley to galvanized iron sheet roofing including all fastening and bolt galvanised iron screws and bolts, lead and bitumen washers etc. complete.(Weight of 6.8 kg/sq.m.).
658Providing and fixing precoated galvanised steel sheet roofing accessories 0.50 mm (+ 0.05 %) total coated thickness, Zinc coating 120 grams per sqm as per IS: 277, in 240 mpa steel grade, 5-7 microns epoxy primer on both side of the sheet and polyester top coat 15- 18 microns using self drilling/ self tapping screws complete :
659Ridges plain (500 - 600mm)
660Barge board (Upto 300 mm)
661Gutter (600 mm over all girth)
662Providing and fixing in position Gypsum board false ceiling with 12.5mm thick Gypsum boards, screwed /fixed to the under structure of suspended G.I.Grid constructed and suspended from the main ceiling consisting of ceiling sections of size 25x50mm maximum center to center distance of 600 milimetre perimeter channel and intermediate channels at maximum center to center distance 1200 milimetre galvanized grid should be fixed to reinforced cement concrete slab. The gypsum board should be fixed to galvanized iron grid with necessary screws. The boards should be taped and filled from under side to give smooth, seamless ceiling. The rate should include necessary additional ceiling sections and intermediate channels. Additional intermediate channels should be fixed to strap hangers for additional support to prevents trap pin gate very 1200 milimetre item to be completed in all respect including necessary sleeves for ducts finishing of joints cutouts, painting includinglabour,material,liftsetc.all complete.
663TOTAL ROOFING
664FINISHING WORK
665Providing internal cement plaster 12mm thick in single coat in cement mortar 1:4 without neeru finish to concrete or brick surfaces, in all positions including scaffolding and curing etc. complete.
666Providing rough cast cement plaster externally in two coats to concrete,brick or stone masonry surfaces in all positions with base coat of 12 to 15mm thick in C.M.1:4 and rough cast treatment 12mm thick in proportion 1:11/2:3 including scaffolding and fourteen days curing complete.
667Labour charges for providing groove in external plaster having width and spaced as directed by engineer incharge etc. complete.
668Providing internal cement plaster 6 mm thick in a single coat in cement mortar 1:3 without neeru finish to concrete surface in all positions including scaffolding and curing etc. complete.
669Providing and fixing chicken mesh of 22 gauge, with about 30 cm. width at the junction of R.C.C members and brick work, of approved quality including fixing mesh in position by necessary drilling in concrete /B.B.masonry and or tying by binding wire etc. complete.
670Providing and applying washable oil-bound distemper of approved colour and shade to old and new surfaces in two coats including scaffolding, preparing the surfaces. (excluding the primer coat.) etc. complete.
671Providing and applying priming coat on concrete/ masonary/ Asbestos Cement plastered surfaces including scaffolding if necessary, preparing the surface by thoroughly cleaning oil, grease, dirt and other foreign matter and sand papering as required etc. complete.
672Providing and applying two coats of textured synthetic paint of approved shade and quality and one coat of primer before applying textured paint including scaffolding if necessary preparing surface by thoroughly cleaning oil, grease, dirt and other materials as required, etc. complete.
673Providing and applying plastic emulsion paint of approved quality, colour and shade to old and new surfaces in two coats including scaffolding, preparing the surface. (excluding the primer coat)etc. complete.
674Providing and applying Two coats of wall care Putty of 2mm thickness for plastered surface and 5-6mm thickness finished concrete surface to Ceiling and Walls to prepare surface even and smooth of Brands BIRLA WHITE, BERGER, BISION, J.K., make, etc complete.a) For plastered walls/ceiling 2mm
675Providing and applying two coats of synthetic enamel paint of approved colour to new /old structural steel work and wood work in buildings, including scaffolding if necessary, cleaning and preparing the surface (excluding primer coat) etc. complete.
676TOTAL FINISHING WORK
677ALUMINIUM WORK
678Providing and fixing in position aluminium partly openable and partly fixed window of any size as per detailed drawing and as directed by Engineerincharge with all necessary alluminium sections including necessary fixtures and fastening with 5 mm thick float glass etc. complete. b) With powder coating Note While arriving at the rate of item of item weight at 6.90 kg/Sqm is considered.
679Providing and fixing in position, Single shuttered aluminium extruded powder coated openable door of overall size 0.9mx2.4m with aluminium door frame of powder coated section 101.60 x 44.75mm , 3.18 mm thick and shutter comprising of powder coated section having bottom and lock rail of size 150 mm x 44.5 mm x 3.00 mm thick top rails 47.62 x 44.45 mm x 3.00 mm thick , vertical style 47.62 x 44.45 mm, 3.00 mm thick and for shutter plain glass panes 5 mm thick for top panels and 12mm thick both side laminated phenol bonded particle board panels for bottom panels etc. , I.S.I. mark , heavy duty, Hydraulic floor spring of 150 kg capacity , having heavy duty concealed lock, necessary beading, glazing clips, PVC gaskets, 250mm length aluminium tower bolts, 150mm dia. pad handle, etc. as per detailed design and drawing or as directed by engineer in charge including all materials , labours, and equipment etc.complete
680TOTAL ALUMINIUM WORK
681TOTAL CIVIL WORK
682ELECTRICAL WORKS
683SUBHEAD- I:DISTRIBUTION BOARD
684Supplying & erecting triple pole and neutral distribution board (TPNDB) with door surface/ flush mounted suitable for 3 pole MCCB as incomer & outgoing SP MCB (24 poles) or TP MCB of 8 ways (24 poles) , on iron/ GI frame. (vertical busbar type) as per specification no. SW-SWR/MCBDB1
685Supplying erecting and marking four pole isolators only switch version of miniature circuit breakers of 63A in provided distribution board complete.
686Supplying, erecting & marking SPMCB 6A to 32A, C-series (for motor/power) in provided distribution board as per specification no. SW-SWR/MCB
687Supplying, erecting & marking SPMCB 6A to 32A, B- series (for lighting) in provided distribution board as per specification no. SWSWR/ MCB
688Providing, erecting and commissioning 2 pole RCCB only of electromagnetic type with 30/100/300 mA sensitivity and having capacity of 63A complete as per specification no. SWRCCB/RCCB
689TOTAL SUB-HEAD I
690SUB-HEAD - II: INTERNAL WIRING
691Point wiring for light/fan/bell hybrid type (Surface type under false ceiling and concealed type for drops & switch boards on walls) in min 20 mm PVC conduit / casing n capping with 1.5 sq.mm. (2+1E) FR grade copper wires, modular type switch,earthing and required accessories as per specificationNo: WGPW/ HW
692Secondary point wiring for additional light/ bell point, concealed type in min 20 mm PVC conduit with 1.5 sq.mm. (2+1E) FR/FRLSH grade copper wires with required accessories as per specification No: WG-PW/CW
693Supplying & erecting mains with 3x2.5 Sq.mm F.R copper PVC insulated wire laid in provided conduit/trunking/inside pole/Bus bars or any other places as per specification No: WGMA/BW
694Supplying & erecting mains with 3x4 sq.mm FR copper PVC insulated wire laid in provided conduit/trunking/inside pole/Bus bars or any other places as per specification No: WGMA/ BW
695Supplying & erecting mains with 3x6 sq.mm F.R copper PVC insulated wire laid in provided conduit/trunking/inside pole/Bus bars or any other places as per specification No: WGMA/ BW
696Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed steel conduit as required
6974 x 10 sq.mm + 2 x 6sq.mm. earth wire
698Supplying and erecting ISI mark modular type switch 6A / 10A duly erected on provided plate and box with wiring connections complete.
699Supplying and erecting ISI mark modular type 5 pin socket with safety shutters 3 module socket 6A 240V AC supply, duly erected on provided plate and box with wiring connections complete duly erected
700Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 6 pin 5/6 & 15/16 amps modular socket outlet and 15/16 amps modular switch, connection etc. as required.
701Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providng and fixing 2 nos. 3 pin 5/6 A modular socket outlet and 2 nos. 5/6 A modular switch, connections etc. as required. (For light plugs to be used in non residential buildings).
702Supplying & erecting original 1.25 mm CRCA sheet metal enclosures with 20A. 2 pin plug & earth socket and 20A. 3 pin plug top with 20A/30A single pole MCB complete erected on angle iron/ GI frame.
703Supplying and erecting electronic type step regulator for ceiling fan 600/ 900/ 1200/ 1400 mm. sweep, complete erected on provided switch board.
704Providing & erecting Hot dipped galvanized perforated type cable tray manufactured from 16 swg (1.6 mm thick) GI sheet of 200 mm width & 75 mm height complete with necessary coupler plates & hardware in approved manner.
705TOTAL SUB HEAD II
706SUB-HEAD III - FANS & LIGHT FIXTURES:
707Supplying & erecting LED 20W tube light fitting (4 feet) with aluminium housing, heat sink, integrated HF electronic driver complete
708Supplying and erecting LED square / circular 16 to 20W down lighter having pressure die-cast aluminium housing, opal translucent cover, mounting arrangement with board for surface type or spring loaded mounting clips for flush type complete
709Supplying and erecting regular/ standard model ceiling fan of 1400mm. sweep complete erected in position as per specification no. FG-FN/CF
710Supplying and erecting fresh air cum exhaust fan of light duty 250 V A.C. 50 cycles 300mm. 1400 RPM rust proof body & blades, wire\ mesh, duly erected in an approved manner.
711Supplying and erecting exhaust fan heavy duty 230 V A.C. 50 cycles 450 mm. 1400 RPM complete erected in position as per specification no. FG-FN/EXF
712TOTAL SUB HEAD III
713SUB HEAD-IV : T.V. , TELEPHONE, DATA SYSTEM, CONDUITING andLAN SYSTEM
714Supplying & erecting telephone copper cable 2 pair with 0.5 mm dia. laid in provided PVC casing capping/ conduit as per specification No. WG-TW
715Supplying & erecting telephone copper cable 10 pair with 0.5 mm dia. laid in provided PVC casing capping / conduit as per specification No. WG-TW
716Providing, fixing connecting and testing of under noted size of solderless telephone tag block Krone make in surface/recess in wall required size of M.S. box with hinged lockable cover duly stove enamel painted.
71710 pair tag block
718Supplying and erecting PVC trunking (PVC casing-ncapping) of size 20 mm with accessories on wall/ceiling as per specification No: WG-MA/CON.
719Supplying and erecting PVC trunking (PVC casing-ncapping) of size 32 mm with accessories on wall/ceiling as per specification No: WG-MA/CON.
720Supplying and erecting ISI mark GI pipe 75/80 mm dia. ‘B’ class at position with accessories complete. Specification no. CW-PLB/GP.
721Supplying and erecting ISI marked modular type telephone(RJ-11) socket one gang with safety shutter, duly erected on provided plate and box with wiring connections complete.
722Supplying and erecting ISI mark modular type T.V. socket single outlet, duly erected on provided plate and box with wiring connections complete.
723Supplying & installing co-axial copper cable low voltage grade RG-6 as per specification No. WG-TW
724Supplying and fixing M.S. box with Phenolic laminate plate 4- way splitter box for TV antennacomplete as required.
725Supplying and fixing of 1 or 2 module (75mm x75mm) size GI boxes with modular base and cover plate for modular switches in recess etc complete as required
726TOTAL SUB HEAD IV:
727SUB HEAD - V: UPS (UNINTERRUPTED POWER SUPPLY)
728Supplying & erecting on line UPS pure sine wave of 5 kVA capacity complete with standard features, along with necessary SMF batteries for 30 mins battery backup, as per specification no. AP-UPS
729TOTAL SUB HEAD V
730Sub-Head - VI -CCTV AND PA SYSTAM
731Video Surveillance System(IP CCTV)
732Supplying, installation, testing and commissioning of 2 megapixels resolution Network Dome Camerafor true HD quality images,2.8 – 12 mm varifocal lens,True Day/Night (TDN) functionality for true color image ,Motion Detection 4 Zones, Multi- Level Sensitivity Privacy Zones 4 Zones,SnapshootSupport JPEG format Password Protection Support Character Display Support(Channel /Date) ONVIF Yes,IR Illumination20-30M IR illuminators for clear images in low light conditions Wide Dynamic Range 3D noise reduction for sharper images and lower bandwidth use in low lightONVIF compliant complete in all respect.Make-Tyco/Mobotix/Pelco.
733Supply, installation, testing & commissioning of 12 Port PoE+ Switch with 2 SFP slots 12 x 10/100/1000 Base-T PoE+ ports and additional 2 100/1000X SFP PORTS Should support PoE+ as per IEEE 802.3 at with PoE budget of 100W.Should support STP, RSTP, MSTP, IGMP v1/v2/v3 snooping, STP root guard, Voice VLAN, MLD snooping (MLDv1 and v2), IEEE 802.3ac VLAN tagging IEEE 802.17/equivalent for sub 50ms ring protection in following scenario : single, dual fibre cuts in ring and when fibre cut at common shared link in between two or more rings.
734Supply, Installation, Testing and Commissioning of 8 Channel 4K NVR with specifications as follow: Processor Quad-core embedded processor; Operating System Embedded LINUX; IP Camera Input 16 channel; Two-way Talk 1 channel Input, 1 channel Output, RCA User Interface GUI; Video Output 2 HDMI, 1 VGA; Video Resolution 3840× 2160, 1920× 1080, 1280× 1024, 1280× 720, 1024× 768 Video Display Split 1st screen: 1/4/8/9/16/25/36 , 2nd screen: 1/4/8/9/16; Channel 16; Motion Detection MD Zones: 396(22×18); Video Loss Supports; Alarm Input 16 Channel, Low Level Effective, Green Terminal Interface; Alarm Output 6 Channel, NO/NC. Playback Play, Pause, Stop, Rewind, Fast play, Slow Play, Next File, Previous File, Next Camera, Previous Camera, Full Screen, Repeat, Shuffle, Backup Selection, Digital Zoom; Max User Account 128 users; Record Interval 1~120 min (default: 60 min), Pre-record: 1~30 sec, Post-record: 10~300 sec; Ethernet 2 RJ-45 port (10/100/1000Mbps); Interface Ports 2 HDMI, 1 VGA, 4 ports (2 Rear USB3.0,2 Front USB2.0), 1 eSATA port, 1 RS485, 1 RS232, 2 RJ45; Protocols HTTP, TCP/IP, IPv4/IPv6, UPNP, RTSP, UDP, SMTP, NTP, DHCP, DNS, IP Filter, PPPOE, DDNS, FTP, Alarm Server, IP Search, ONVIF 2.4, CGI Conformant; Power Supply Single, AC 100~240V, 50/60 Hz; Power Consumption <16.7W (without HDD); Working Temp -10 ~+55°C / 10~90%RH / 86~106kpa;Certifications: UL,FCC ,CE, ISO certified.
735Supply, Installation, Testing and Commissioning of 4 TB Internal Surveillance Hard Disk for recording .
736Supply, Installation, Testing & Commissioning of 9U Rack with specifications as follows: Width x Depth: 550mm(width) * 500mm (Depth); Height: 9U; Ventilation: Fan 90CFM 230V AC fitted on rack top; Provisions:Front toughened glass with lock and key; Wiring: 1U Cable Manger Metal with PVC Loop; Cable Manager: On bottom of Rack; Power Distribution: PDU 6 Point 5Amp Socket, indian round pin with power Cable; Accessories : Mounting hardware packet of 10 piece.
737Supplying and fixing of HDMI Cable 3 mtrs length.
738Network Wiring for Cameras/devices with CAT 6e cable from NVR in exposed / recessed 25 mm dia MS Conduit including termination and providing/fixing 1.2 mm thick GI box with grid plates with earthing complete in all respect.
739Power wiring for Cameras/devices with 3 x 1.5 sq mm FRLS wire in exposed / recessed 25 mm dia MS Conduit including termination and providing/fixing 1.2 mm thick GI box with grid plates with earthing complete in all respect.
740TOTAL SUB HEAD V
741Sub-Head - VII - DISTRIBUTION PANELS
742Design, manufacture, supply,including supervision during installation, testing and commissioningof 2 mm thick MS sheet steel fabricated cubicle type Panel dust and verminproof complete with hinged and lockable doors .The Sheet Steel shall under go minimum eight tank treatment followed by finishing treatment of powder coating with 70 micron minimum thickness. All the panels shall be floor mounted and dead front construction complete with interconnections. (Form IIIB)
743Note:-
744The panels shall beFRONT operated, with cable entry from the top.Earth bus shall be part of the panel.) (All MCB to be "C" Curve)
745The following provisions shall be required to be made in the Distribution Panel as detailed below:
746All live accessible parts shall be shrouded with 1mm thick polycarbonate/3 mm thick FRP sheet and all equipment shall be finger touch proof. The busbar insulation shall be with heat shrinkable sleeves according to the colour code. SMC shrouds and busbar supports shall be used. All MCCB door handle shall be interlocked and lockable in OFF position.
747Galvanised hardware with zinc passivation shall be used in fabrication of Switchboards.
748Suitable Aluminium earth bus to be provided throughout the length of Switchboards.
749All indication lamps / illuminated push buttons shall be LED type.
750Coil of all motor starters shall be fed from 440 V / 230 V Control Transformer.
7512A SP MCBs shall be used as backup protections.
752All MCCBs shall be variable plug setting type with thermal magnetic up to 630 A rating and with microprocessor based releases above 630 A rating, line load reversibility, Ics = 100% Icu,& rotary handle.
753All control& power wiring shall be broughtout upto the cable alley in the terminal blocks.
754An approval shall be taken for each panel before manufacturing.
755Provision of one 6/16 amp socket & compartment lighting for each vertical section of main panel.
756Illuminated push button on Starter Panels of Pumps.
757Interlocking / Auto start command terminals for starter Panels.
758All breaking Capacity for ACB to be Ics=100%Icu and Icw for 1 sec..
759All breaking Capacity for MCCB to beIcs=100%Icu.
760All MCB to be C Curve
761Kitchen Panel
762Incoming:
7631 no. of 100Amp FPMCCB of 16 KA breaking capacity &Trip setting as required.
764Metering for incoming:
765Digital Multifunction meter (MFM-4) with RS-485 communication port for measurement ofPF, V, A & Hz , equivalent to EM6459, with CT as required.
766Phase indicating lamps RYBwith 6 Amps SP MCB back up.
767Bus Bars:
768Electrolytic high conductivity Aluminium three phase and neutral busbars rated at 150 Amps, insulated with heat shrinkable coloured PVC sleeves & clip on shrouds for joints. Current density of Bus Bar to be 1.3 sq.mm / amp.
769Outgoing (All MCB/MCCB shall be suitable for motor duty):
7705 Nos. 63A FP MCB of 10 KA breaking capacity.
7712 Nos. 63A DP MCB of 10 KA breaking capacity.
772Kitchen Panelas described above shall be complete with all interconnections, risers, internal wiring, labels, terminal blocks etc. complete as required.
773TOTAL SUB HEAD- VII
774Sub-Head -VIII- MISCELLANEOUS ITEMS CABLE & SAFETY CHART
775Supplying, erecting & terminating XLPE armoured cable 3½ core 35 sq. mm. aluminium conductor with continuous 5.48 sq. mm. (12 SWG) G.I. earth wire complete erected with glands & lugs, on wall/ trusses/pole or laid in provided trench/ pipe as per specification no. CB-LT/AL
776Providing & erecting epoxy outdoor / indoor end termination kit for LT XLPE armoured cable 25 to 50 sq. mm. cable, with necessary material as per specification no. CB-JT/LT
777Supplying and laying (including excavation of suitable width & depth up to 90 cm) 200 mm outside dia, double wall corrugated pipes (DWC) of HDPE for enclosing cable below ground/road surface, to required depth complete.
778TOTAL SUB HEAD VIII
779SUB-HEAD -IX: EARTHING
780Providing earthing with galvanized iron earth plate size 60 x 60 x 0.6 cm complete with all materials, testing & recording the results as per specification no. EA-EP
781Supplying and erecting aluminium strip of required sizes used for earthing on wall and/or any other purpose with necessary aluminium clamps fixed on wall painted with bituminous paint in an approved manner with joints required. As per specification no EAEP.
782Supplying and erecting GI earth wire of high purity of different sizes used for earthing or any other purposes on wall with necessary G. I. Clamps fixed on wall/cable/ conduit with screws in an approved manner.
783Providing pipe type earthing with 40mm. dia. G.l. pipe or 20 mm dia. G.l. Rod complete with all materials as per specification no. EAEP
784TOTAL SUB HEAD IX:
785SUB-HEAD -X: INTELLIGENT FIRE ALARM SYSTEM
786Supplying, installing, testing and commissioning manual call point (Pill box) with break glass push button in metal enclosure complete as per specification no. FF-FAAS/MCP
787Supplying, installing, testing and commissioning hooters with CRCA enclosure complete as per specification no. FF-FAAS/HTR
788Supplying, installing, testing and commissioning FR, XLPE armoured cable 2 core 1.5 sq.mm. copper conductor complete erected on wall/ ceiling complete as per specification no. CBLT/ CU
789TOTAL SUB HEAD X
790SUB-HEAD -XI:-EXTERNAL LIGHTING
791Supplying, erecting & terminating XLPE armoured cable 2 core 6 sq. mm. aluminium conductor with continuous 5.48 sq. mm. (12 SWG) G.I. earth wire complete erected with glands & lugs, on wall/ trusses/pole or laid in provided trench/ pipe as per specification no.CB-LT/AL
792Supplying, erecting & terminating XLPE armoured cable 4 core 6 sq. mm. aluminium conductor with continuous 5.48 sq. mm. (12 SWG) G.I. earth wire complete erected with glands & lugs, on wall/ trusses/pole or laid in provided trench/ pipe as per specification no. CB-LT/AL
793Providing & erecting epoxy outdoor / indoor end termination kit for LT XLPE armoured cable 2.5 to 16 sq. mm. cable, with necessary material as per specification no. CB-JT/LT
794Supplying & erecting mains with 3x2.5 Sq.mm F.R copper PVC insulated wire laid in providedonduit/trunking/inside pole/Bus bars or any other places as per specification No: WGMA/ BW
795Supplying and laying (including excavation of suitable width & depth up to 90 cm) 200 mm outside dia, double wall corrugated pipes (DWC) of HDPE for enclosing cable below ground/road surface, to required depth complete.
796Providing & erecting 4 m high (clear height) galvanised octagonal pole with foundation bolts having bottom of 130 mm A/F, top 70 mm A/F on provided foundation as per specification no.OHPL/ OPL
797Providing & erecting 7 m high (clear height) galvanised octagonal pole with foundation bolts having bottom of 130 mm A/F, top 70 mm A/F on provided foundation as per specification no.OHPL/ OPL.
798High Mast
799Supplying and erecting 12.5 m (clear height) High Mast (Top- 150mm, Bottom- 360mm) with lowering and raising motorized unit, lantern carriage assembly suitable for max. 6 nos. luminaries and its control gear box, lightning finial arrangement for fixing aviation light and foundation bolts on provided foundation as per specification no.OH-PL/HM (excluding luminaries ).
800Supplying and erecting LED Flood light fitting of 120W, including lamp, with PF > 0.95,class IP 65 and above Housing of pressure die cast aluminium alloy and heat sink extruded aluminium complete per specification No FG-ODF/FLS-2
801Supplying and erecting 40W LED post top made in cast aluminium spigot housing with decorative clear opal acrylic diffuser and IP65 protection on provided pole/ bracket
802Supplying and erecting mushroom shaped integral 12W-16W LED decorative bollard upto 680mm with IP65 protection on provided foundation complete.
803Supplying and erecting LED street light fitting 100W, including lamp, with PF > 0.95 class IP 65 and above housing of pressure die cast aluminium alloy and heat sink extruded aluminium complete per specification No FG-ODF/FLS-2.
804F.P.(External Lighting)
805Design, manufacture,Supply, Installation, testing and commissioning at works ofDouble door panel fabricated with minimum 2mm thick CRCA sheet, Conform to IS Specification, with IP-55 enclosure protection, as per IS-2137(Revised), floor mounting free standing on a suitable massanory pedestal outdoor type panel,provided with hinged detachable and lockable outer opening doors with the following incoming/outgong MCCB/ MCBs mounted therein including making connections/ interconnections, earthing, painting etc. as required.The panel shall have canopy arrangement on the top.All MCB to be C curve .
806Feeder Pillar
807Incoming
808The incoming shall comprise the following :-
8091 No 63 A FP MCCB, 16 KA service breaking capacity with heavy duty solid neutral link alongwith Earth fault relay and CBCT.
810Metering for incoming:
811Digital Multifunction meter (MFM-4) with RS-485 communication port for measurement ofPF, V, A & Hz , equivalent to EM6459, with CT as required.
812Phase indicating lamps RYBwith 2 Amps SP MCB back up.
813Bus Bars
81480 Amps TPN Aluminium Bus Bars of suitable length Bus bars shall be colour coded and insulated by heat shrinkable sleaves & clip on shrouds for joints. The current density of Bus bar shall be 1.2 sq.mm./amp.
815Outgoing (All MCB shall be suitable for motor duty& with heavy duty detachable solid neutral link ):
81612 nos 25A DP MCB 10 KA breaking capacity controlled by and including providing 63 DP MCB, 63 A DP contactor and Timer.
817Feeder Pillar - X described as above and all as per specification.
818Earthing
819Providing earthing with galvanized iron earth plate size 60 x 60 x 0.6 cm complete with all materials, testing & recording the results as per specification no. EA-EP
820Supplying and erecting aluminium strip of required sizes used for earthing on wall and/or any other purpose with necessary aluminium clamps fixed on wall painted with bituminous paint in an approved manner with joints required. As per specification no EAEP.
821Supplying and erecting GI earth wire of high purity of different sizes used for earthing or any other purposes on wall with necessary G. I. Clamps fixed on wall/cable/ conduit with screws in an approvedmanner.
822Providing pipe type earthing with 40mm. dia. G.l. pipe or 20 mm dia. G.l. Rod complete with all materials as per specification no. EAEP
823TOTAL SUB HEAD XI:
824TOTAL ELECTRICAL WORK
825EXTERNAL PLUMBING WORKS
826(EXTERNAL SEWERAGE SYSTEM)
827Earth work in excavation by mechanical means (hydraulic excavator)/manual means over areas (exceeding 30cm in depth. 1.5m in width as well as 10 sqm on plan) including disposal of excavated earth, lead upto 50m and lift upto 1.5m; disposed earth to be levelled and neatly dressed.
828Providing, laying and jointing glazed stoneware pipes class SP-1 with stiff mixture of cement mortar in the proportion of 1:1 (1 cement : 1 fine sand) including testing of joints etc. complete :
829150 mm diameter
830200 mm diameter
831250 mm diameter
832Providing and laying cement concrete 1:5:10 (1 cement : 5 coarse sand : 10 graded stone aggregate 40 mm nominal size) all-round S.W. pipes including bed concrete as per standard design :
833150 mm diameter S.W. pipe
834200 mm diameter S.W. pipe
835250 mm diameter S.W. pipe
836Providing and laying cement concrete 1:5:10 (1 cement : 5 coarse sand : 10 graded stone aggregate 40 mm nominal size) up to haunches of S.W. pipes including bed concrete as per standard design :
837150 mm diameter S.W. pipe
838200 mm diameter S.W. pipe
839250 mm diameter S.W. pipe
840Providing and fixing square-mouth S.W. gully trap class SP-1 complete with C.I. grating brick masonry chamber with water tight C.I. cover with frame of 300 x300 mm size (inside) the weight of cover to be not less than 4.50 kg and frame to be not less than 2.70 kg as per standard design:
841180x150 mm size P type
842With Sewer bricks conforming to IS : 4885
843Constructing brick masonry manhole in cement mortar 1:4 ( 1 cement : 4 coarse sand ) with R.C.C. top slab with 1:1.5:3 mix (1 cement : 1.5 coarse sand (zone- III) : 3 graded stone aggregate 20 mm nominal size), foundation concrete 1:4:8 mix (1 cement : 4 coarse sand (zone- III) : 8 graded stone aggregate 40 mm nominal size), inside plastering 12 mm thick with cement mortar 1:3 (1 cement : 3 coarse sand) finished with floating coat of neat cement and making channels in cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) finished with a floating coat of neat cement complete as per standard design :
844Inside size 90x80 cm and 45 cm deep including precast RCC Cover with frame (light duty) 455x610 mm internal dimensions, total weight of cover and frame to be not less than 38 kg (weight of cover 23 kg and weight of frame 15 kg) :
845With Sewer bricks conforming to IS : 4885
846Inside size 120x90 cm and 90 cm deep including C.I. cover with frame (heavy duty) 560 mm internal diameter, total weight of cover and frame to be not less than 208 kg (weight of cover 108 kg and weight of frame 100 kg)
847With Sewer bricks conforming to IS : 4885
848Extra for depth for manholes :
849Size 90x80 cm
850With Sewer bricks conforming to IS : 4885
851Size 120x90 cm
852With Sewer bricks conforming to IS : 4885
853Providing orange colour safety foot rest of minimum 6 mm thick plastic encapsulated as per IS : 10910, on 12 mm dia steel bar conforming to IS: 1786, having minimum cross section as 23 mmx25 mm and over all minimum length 263 mm and width as 165 mm with minimum 112 mm space between protruded legs having 2 mm tread on top surface by ribbing or chequering besides necessary and adequate anchoring projections on tail length on 138 mm as per standard drawing and suitable to with stand the bend test andchemical resistance test as per specifications and having manufacture’s permanent identification mark to be visible even after fixing, including fixing in manholes with 30x20x15 cm cement concrete block 1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size) complete as per design.
854Making connection of drain or sewer line with existing manhole including breaking into and making good the walls, floors with cement concrete 1:2:4 mix (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) cement plastered on both sides with cement mortar 1:3 (1 cement : 3 coarse sand), finished with a floating coat of neat cement and making necessary channels for the drain etc. complete :
855For pipes 250 to 300 mm diameter
856TOTAL (EXTERNAL SEWERAGE SYSTEM) C/F TO SUMMARY
857(EXTERNAL STORM WATER SYSTEM)
858Earth work in excavation by mechanical means (hydraulic excavator)/manual means over areas (exceeding 30cm in depth. 1.5m in width as well as 10 sqm on plan) including disposal of excavated earth, lead upto 50m and lift upto 1.5m; disposed earth to be levelled and neatly dressed.
859Providing and laying non-pressure NP2 class (light duty) R.C.C. pipes with collars jointed with stiff mixture of cement mortar in the proportion of 1:2 (1 cement : 2 fine sand) including testing of joints etc. complete :
860150 mm dia. R.C.C. pipe
861250 mm dia. R.C.C. pipe
862300 mm dia. R.C.C. pipe
863Constructing brick masonry road gully chamber 50x45x60 cm with bricks in cement mortar 1:4 (1 cement : 4 coarse sand) including 500x450 mm pre-cast R.C.C. horizontal grating with frame complete as per standard design :
864With common burnt clay F.P.S. (non modular) bricks of class designation 7.5
865Providing and laying Non Pressure NP-3 class (Medium duty) R.C.C. pipes including collars/spigot jointed with stiff mixture of cement mortar in the proportion of 1:2 (1 cement : 2 fine sand) including testing of joints etc. complete
866450 mm dia RCC pipes
867Making connection of drain or sewer line with existing manhole including breaking into and making good the walls, floors with cement concrete 1:2:4 mix (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) cement plastered on both sides with cement mortar 1:3 (1 cement : 3 coarse sand), finished with a floating coat of neat cement and making necessary channels for the drain etc. complete :
868For pipes 250 to 300 mm diameter
869Total (EXTERNAL STORM WATER SYSTEM) C/F TO SUMMARY
870(EXTERNAL DOMESTIC WATER SYSTEM)
871Providing and fixing G.I. pipes complete with G.I. fittings including, trenching and refilling etc. external works
87232 mm dia nominal bore
873Painting G.I. pipes and fittings with two coats of anti-corrosive bitumastic paint of approved quality :
87432 mm dia nominal bore
875Providing and filling sand of grading zone V or coarser grade all-round the G.I. pipes in external work.
87632 mm dia nominal bore
877Providing and fixing gun metal gate valve with C.I. wheel of approved quality
878(screwed end) :
87932mm nominal bore
880Constructing masonry Chamber 60x60x75 cm inside, in brick work in cement mortar 1:4 (1 cement : 4 coarse sand) for sluice valve, with C.I. surface box 100mm top diameter, 160 mm bottom diameter and 180 mm deep ( inside) with chained lid and RCC top slab 1:2:4 mix (1 cement : 2 coarse sand : 4 graded stone aggregate 20mm nominal size ) , i/c necessary excavation, foundation concrete 1:5:10 (1 cement : 5 fine sand : 10 graded stone aggregate 40 mm nominal size) and inside plastering with cement mortar 1:3 (1 cement : 3 coarse sand) 12 mm thick, finished with a floating coat of neat cement complete as per standard design :
881With common burnt clay F.P.S.(non modular) bricks of class designation 7.5
882TOTAL (EXTERNAL DOMESTIC WATER SYSTEM) C/F TO SUMMARY
883TOTAL EXTERNAL PLUMBING COST WITHOUT GST (Rs.)
884FIRE FIGHTING WORKS
885SUB HEAD-A (PIPING & VALVES)
886Providing, laying, testing & commissioning of "C" class heavy duty MS pipe conforming to IS 3589/IS 1239 including Welding, fittings like elbows, tees, flanges ,tapers, nuts bolts, gaskets etc. and fixing the pipe on the wall/ceiling with suitable clamp/support frame and painting with two or more coats of synthetic enamel paint of required shade complete as required :
88725 mm dia.
888100mm dia
889Providing, installation, testing and commissioning of non-return valve of following sizes confirming to IS:5312 complete with rubber gasket, GI bolts, nuts,washers etc.as required :
890100 mm dia
891Providing and fixing gun metal gate valve with C.I. wheel of approved quality (screwed end) :
89225 mm dia.
893Supplying, fixing, testing and commissioning of butterfly valve of PN 1.6 rating with bronze/gunmetal seat duly ISI marked complete with nuts, bolts, washers, gaskets conforming to IS 13095 of following sizes as required :
894100 mm dia.
895Providing and fixing in position the industrial type pressure gauges with gun metal / brass valves complete as required
896Providing,installation,testingandcommissioningof stainlesssteelY-strainerfabricatedoutof1.6mm thickstainlesssteel,Grade304,sheetwith3mmdia holes with stainless steel flange.
897100mm dia
898Providing & fixing of pressure switch in M.S. pipe line including connection etc. as required.
899Providinglaying,testing&commissioningof"C"class heavydutyMSPipeconformingtoIS1239/3589i/c fittingslikeelbows,tees,flanges,tapers,nutsbolts, gasketsetc.ingroundincludingwelding,excavation& providingcementconcreteblocksassupports, anticorrosivetreatmentwithcoaltar/asphalttapeasper IS10221,refillingthetrenchetc.offollowingsizes complete as required.
900TOTAL SUB HEAD-A (PIPING & VALVES)
901SUB HEAD-B (FIRE HYDRANT ACCESSORIES)
902Supplying and fixing single headed internal hydrant valve with instantaneous Gunmetal/Stainless Steel coupling of 63 mm dia with cast iron wheel ISI marked conforming to IS 5290 (Type -A) with blank Gunmetal/Stainless Steel cap and chain as required :
903Single headed Gunmetal
904Supplying and fixing first-aid Hose Reel with MS construction spray painted in post office red, conforming to IS 884 complete with the following as required. 20 mm nominal internal dia water hose thermoplastic (Textile reinforced) type -2 as per IS: 12585 20 mm nominal internal dia gun metal globe valve & nozzle. Drum and brackets for fixing the equipmets on wall. Connections from riser with 25 mm dia stop gun metal valve & M.S. Pipe and socket.
90530m
906Supplying and fixing 63 mm dia, 15 m long RRL hose pipe with 63 mm dia male and female couplings duly bound with GI wire, rivets etc. conforming to IS 636 (type-A) as required :
907Gun Metal
908Supplying & fixing 63 mm dia gun metal short branch pipe with 20 mm nominal internal diameter size nozzle conforming to IS 903 suitable for instantaneous connection to interconnect hose pipe coupling as required :
909Gun Metal
910Providing and fixing doorwith frame for all internal fire hydrants fabricated from 20x20x3mm and40x20x3 mm aluminium hollow box sections mounted with 3 no. of 100 mm Aluminium butt hinge onAluminium angle frame of 45x45x5mm size with hold fasts fixed to wallwithP.C.C. (1:2:4) blocks 100x100x100 mm including 2 nos allen key lock for locking along with padlock arrangement& fully glazed with 4 mm thick float glass approved by local Fire Authority, powder coated fire red finish with " fire hose" written on front suitable to house 15 mm long two length of canvas hose with couplings, one no of branch pipe, one fire mans axe and two numbers of portable extinguishers, first aid fire hose and supports for hoses, branch pipes, Axe and hose reel. Size 1200x 600 mm complete as per approved design including necessary fixing arrangement for hoses & axe and branch pipe.)
911Supplying and fixing of Fire Man"s Axe with heavy insulated rubber tested upto 20 KV and confirming to IS :926.
912Supplying and fixing orifice plate made out of 6 mm thick stainless steel (Grade 304) with orifice of required size to be fitted between flange & landing valve of external and internal hydrants to reduce pressure at the outlet to the level of 3.5 kg/cm2 complete as required.
913Supplyingandfixingoffirebrigadeconnectionof cast iron body with gun metal male instantaneous inlet couplingscompletewithcapandchainasreqd.for suitabledia MS pipe connectionconforming to IS 904 as required :
9142 way-100 mm dia M.S. Pipe
915Supplying and fixing air vessel made of 250 mm dia, 8 mm thick MS sheet, 1200 mm in height with air release valveontopandflangedconnectiontoriser,drain arrangementwith25mmdiagunmetalwheelvalve withrequiredaccessories,pressuregaugeand paintingwith synthetic enamel paint of approved shade as required.
916TOTAL SUB HEAD-B (FIRE HYDRANT ACCESSORIES)
917SUB HEAD-C (FIRE EXTINGUISHERS & MISC. ITEMS)
918Providing and fixing Carbon-di-oxide fire extinguishers consisting of welded M.S cylindrical body, squeeze lever discharge valve fitted with internal discharge tube, 30cms long high pressure discharge hose, dischargenozzle, suspension bracket, confirming to IS: 15683 finished externally with redenamelpaint andfixed towall with brackets with rawl plug/dash fasteners complete with internal charge. Capacity 4.5 kg. ISI Marked.( Contractor should submit test certificate form manufacturer along with serial number of every extinguishers supplied.)
919Providing and fixing waterCo2(ISI marked) extinguishers includingall accessoriesas per IS specification with wall bracket with rawl plug
920Capacity 9 liters.(IS:15683)
921Providing and fixing of self illuminated / auto glow "EXIT" signs printed on photoluminescentsheet containing self illuminated base chemical, of appropriate size not less than 400 x 150 mm, suspended from ceiling or fixed to the walls with accessories as required and as directed at site.
922TOTAL SUB HEAD-C (FIRE EXTINGUISHERS & MISC. ITEMS)
923SUB HEAD-D (FIRE PUMPS & ACCESSORIES)
924Supplying,installation,testingandcommissioningof electric driven terrace pump suitable forautomatic operationandconsistingoffollowing,completeinall
925respects, as required: (Terrace Pump)
926(a)Horizontal type, multistage, centrifugal, split casing pump of cast iron body & bronze impeller with stainless steel shaft, mechanical confirming to IS : 1520
927b)SuitableHPsquirellcageinductionmotorTEFCtype suitable for operation on 415 volts, 3 phase, 50 Hz, AC supplywithIP55classofprotectionforenclosure, horiziontalfootmountedtypewithClass-"F"insulation, conforming to IS-325.
928(c)M.S.fabricated common base plate, coupling, coupling guard, foundation bolts etc.as required.
929(d)Suitablecementconcretefoundationdulyplastered and with anti vibration pads.
930450 lpm at 35 m Head
931Providingandfixingliquidlevel controller for fire pumpto stop fire pump in caseoflow level of water in tank , cost of conduit, cable and panel including making connection to pump panel and commissioning complete.
932Float type Sensor with panel and installation
933Providing and fixing rubber expansion joint (to provide relief from stresses at pipe flanges)as per specification of the manufacturers and direction of Engineer in chief PN-16 rating
934100 mm dia
935150 mm dia
936TOTAL SUB HEAD-D ((FIRE PUMPS & ACCESSORIES)
937TOTAL FIRE FIGHTING WORKS
938INTERNAL PLUMBING
939SANITARY INSTALLATIONS
940Providing and fixing White glazed with bottle trap earthenware Wash Hand Basin of 55x40 cm size including cold water piller taps, brackets, rubber plugs and brass chain, stop tap, chromium plate bottle trap and necessary pipe connections including UPAC waste pipe and trap upto the outside face of the wall, making good the damaged surface, testing etc. complete.
941Providing and fixing C.P. BIB cock with wall flange of approved make including necessary sockets/ union nut etc. complete as directed by Engineer in charge.
942Providing and fixing C.P. Angular stop clock with wall flange of approved make continental including necessary sockets/union nut etc. complete.
943Providing and fixing PTMT liquid soap container 109 mm wide, 125 mm high and 112 mm distance from wall of standard shape with bracket of the same materials with snap fittings of approved quality and colour, weighing not less than 105 gms.
944Providing and fixing uplasticised PVC connection pipe with brass unions :
94545 cm length
94615 mm nominal bore
947Providing and fixing stainless steel sink of size 600 x 510 x 200 mm incluidng coupling, outlet pipe, elbow and other necessary fitting, finishing etc. complete.
948TOTAL SANITARY INSTALLATIONS
949INTERNAL SEWERAGE & DRAINAGE
950Supplying installation testing and commissoning of Hubless centrifugally cast iron pipes as per ISI 15905 equivalent to NECO inclusive of all necessary special fitting like bends, tees, and caps, "Y" bends for cleaning offsets, junctions, cowls, etc. lad under floor/fixed on walls and in pipe shafts etc. complete. The quoted rate should include lead and lifting charges to all levels, necessary scaffolding and supports like hanger supports grip bolts and CV sheet 304 grade clamps etc. with prior approval of concerned Superitending Engineer.
951100 mm dia
952Providing and fixing 10cm C.I. Nahani Trap including C.I. grating bend and piece of C.I. pipe upto the outside face of the wall complete.
953Providing and fixing P.V.C. Rain water pipes of 110mm outer diameter and having wall thickness of 2.2 to 2.7 mm confirming to I.S. 13592- 1992 including proper rainwater receiving recess with P.V.C. plug, bend, necessary fittings, such as, offsets, shoes, inluding fixing the pipe on wall using approved wooden cleats projecting 25mm to 40mm from face of wall a fixing with clips of approved quality and number ,filing the joint using rubber gasket with solvent cement and properly resting the shoe of pipes on C.C. or masonry blocks, including necessary scaffolding and maintenance for 3 yrs for any leakages or dislocations of pipes. All the P.V.C. fittings and additional 2 piece socket clips shall be got approved from engineer in charge etc. complete.
954Providing and fixing to the inlet mouth of rain water pipe cast iron grating 15 cm diameter and weighing not less than 440 grams.
955TOTAL INTERNAL SEWERAGE & DRAINAGE
956INTERNAL WATER SUPPLY
957Providing and fixing on walls/ ceiling/ floor 15 mm dia. CPVC pipe with necessary fittings, remaking good the demolished portion etc. complete. Including removing existing pipe line if necessary and conveying and stacking the same in PWD chowky or as directed etc. complete.
958Providing and fixing on walls/ceiling/floor 20 mm dia. CPVC pipe with necessary fittings, remaking good the demolished portion etc. complete. Including removing existing pipe line if necessary and conveying and stacking the same in PWD chowky or as directed etc. complete.
959Providing and fixing on walls/ ceiling/ floor 25 mm dia. CPVC pipe with necessary fittings, remaking good the demolished portion etc. complete. Including removing existing pipe line if necessary and conveying and stacking the same in PWD chowky or as directed etc. complete.
960Providing and fixing on walls/ ceiling/ floors, 25 mm dia. heavy grade having embossed as ISI Mark galvanised iron pipes weight of 3.01 Kg/meter with necessary fittings . remaking good the demolished portion and applying primer of anti-corrosive oil paint 2 coats Including necessary scaffolding and removing existing pipe line if necessary and conveying and stacking the same in PWD chowky or as directed etc. complete.
961Providing and fixing gun metal gate valve with C.I. wheel of approved quality (screwed end) :
96225 mm nominal bore
96320 mm nominal bore
96432 mm nominal bore.
96540 mm nominal bore
96650 mm nominal bore
967Providing and fixing ball valve (brass) of approved quality, High or low pressure, with plastic floats complete :
96815 mm nominal bore
96920 mm nominal bore
97025 mm nominal bore
971Prividing and Fixing automatic "NO-Touch " electric hand-driers complete with all accessories & fittings. (Make: Jaquar Model No. HDR-SAP-M99ACS)
972Providing and fixing Water cooler with inbuilt RO and storage complete including fixing in position.
973Providing and fixing H.D.P container Syntex or alike one piece moulded water tank made out of low density polythyler and built corrugation including of delivery up to destination hoisting and fixing of accessories such as inlet, outlet overflow of all tanks capacity above 1000 to 20,000 litres.
974TOTAL INTERNAL WATER SUPPLY
975TOTAL INTERNAL PLUMBING
976PART-BTOTAL OF KITCHEN AND DINNING HALL
977PART-C TOILETBUILDING
978CIVIL WORK OF TOILET BUILDING
979EARTH WORKS
980Excavation for foundation in earth, soil of all types, sand, gravel and soft murum, including removing the excavated material upto adistance of 50m. beyond the building area and stacking and spreading as directed, dewatering, preparing the bed for the foundation and necessary backfilling, ramming, watering including shoring and strutting etc. complete. (Lift upto 1.5 m.) By Mechanical Means.
981Excavation for foundation in earth, soils of all types, sand,gravel and soft murum, including removing the excavated material upto a distance of 50 metres beyond the building area and stacking and spreading as directed, dewatering, preparing the bed for the foundation and necessary back filling, ramming, watering including shoring and strutting etc. complete. (Lift from 1.5m to 3.0m)
982Excavation for foundation in Soft rock and old cement or lime masonry foundations including removing the excavated material upto a distance of 50 metres beyond the building area and stacking as directed, including dewatering, preparing the bed for the foundation and necessary back filling with available earth /murum, ramming, watering including shoring and strutting etc. complete (lift upto 1.5m)
983Excavating trenches of required width for pipes, cables, etc. including excavation for sockets, and dressing of sides, ramming of bottoms, depth upto 1.5m including getting out the excavated soil, and then returning the soil as required, in layers not exc
984All kinds of soil.
985Pipes, cables, etc. exceeding 80mm dia but not exceeding 300mm dia.
986Filling in plinth and floors withapprovedexcavated material in 15cm. to 20cm. layers including watering and compacting etc. complete.
987Disposal of excavated excess earth/Ordinary rock away from the site including conveyance of materials up to an average lead of 5KM away from the site, and correspondiong required lift, loading, unloading etc complete as directed by the Engineer-in-charge. (The quantity is net quantity of capacity of truck after deduction of 20% for looseness)(considering the maximum disposal location at 5 KM distance)
988Earth: By mechanical transport including loading, unloading and stacking. (Lead upto 5KM away from the site)
989Ordinary rock:By mechanical transport including loading, unloading and stacking. (Lead upto 5KM away from the site)
990Providing and filling in the foundation with sand of approved quality including watering, compacting etc. complete. (To be executed with prior approval of Superintending Engineer)
991Labour charges for removing grass, thorney shrubs, Jungli shrub, Kubabul and alike grass along roadside making the ground clean by showel and phavaras etc. complete.
992Providing preconstructional antitermite treatment as per I.S. 6313 (Part-II) by treating the top surface of plinth filling at the rate of 5 litres of emulsion concentrate at 1.0 percent ofclorophyrifosper square metre of surface area covering ten years guarantee on bond paper.
993Providing general pest control services to the building to control the nuisance of cockroaches, lizards, pin bores and other insects etc. with 4 operations in a year and monthly check up.
994TOTAL EARTH WORK
995CONCRETEWORKS
996Providing and laying Cast in situ/Ready Mix cement concrete in M-10 of trap/ granite/ quartzite/ gneiss metal for foundation and bedding including bailing out water, formwork, laying/pumping, compacting, roughening them if special finish is to be provided, finishing if required and curing complete, with fully automatic micro processor based PLC with SCADA enabled reversible Drum Type mixer/concrete Batch mix plant (Pan mixer) etc. complete.With natural sand/V.S.I. quality Artificial Sand
997Providing and laying Cast in situ/Ready Mixcement concrete in M15 of trap/ granite/quartzite/gneiss metal for steps including steel centering, plywood/steel formwork, laying/pumping, compacting, roughening them if special finish is to be provided, finishing uneven and honeycombed surface and curing etc. complete. The Cement Mortar 1:3 plaster is considered for rendering uneven and honeycombed surface, only. Newly laid concrete shall be covered by gunny bag, plastic, tarpaulin etc. (Wooden centering will not be allowed.),with fully automatic micro processor based PLC with SCADA enabled reversible Drum Type mixer/concrete Batch mix plant (Pan mixer) etc. complete. With natural sand/V.S.I. quality Artificial Sand
998Providing and laying damp proof course 50 mm thick in M20 cement concrete layer and bitumen / using cement with waterproofing compound curing, formwork etc. complete.
999Providing and applying Bitumen VG30/VG40 layer at 2 kg. per square meter over the terrace, structural slab including cleaning the surface for waterproofing as directed complete
1000Making plinth protection 50mm thick of cement concrete 1:3:6 (1 cement : 3 coarse sand (zone - III) : 6 graded stone aggregate 20 mm nominal size) over 75mm thick bed of dry brick ballast 40 mm nominal size, well rammed and consolidated and grouted with fine sand, including necessary excavation, levelling & dressing & finishing the top smooth.
1001TOTAL CONCRETE WORK
1002REINFORCED CEMENT CONCRETE WORK
1003Providing and laying Cast in situ/Ready Mix cement concrete M-30 of trap / granite /quartzite/ gneiss metal for R.C.C. work in foundations like raft, strip foundations, grillage and footings of R.C.C. columns and steel stanchions etc. columns as per detailed designs and drawing or as directed including centering, formwork, cover blocks laying/pumping, compaction finishing the formed surfaces with cement mortar 1:3 of sufficient minimum thickness to give a smooth and even surface or roughening if special finish is to be provided and curing etc. complete. (Excluding reinforcement and structural steel). with fully automatic micro processor based PLC with SCADA enabled reversible Drum Type mixer/ concrete Batch mix plant (Pan mixer) etc. complete. With natural sand/V.S.I. quality Artificial Sand
1004Providing and laying Cast in situ/Ready Mix cement concrete M-25 of trap / granite /quartzite/ gneiss metal for R.C.C. columns as per detailed designs and drawings or as directed including centering, formwork, cover blocks compacting and roughening if special finish is to be provided and curing etc. complete. (Excluding reinforcement and structural steel).with fully automatic micro processor based PLC with SCADA enabled reversible Drum Type mixer/ concrete Batch mix plant (Pan mixer) etc. complete. With natural sand/V.S.I. quality Artificial Sand
1005Providing and laying Cast in situ/Ready Mix cement concrete in M-25 of trap/ granite/ quartzite/ gneiss metal for R.C.C. beams and lintels as per detailed designs and drawings or as directed including centering, formwork, cover blocks, laying/pumping, compactionand roughening the surface if special finish is to be provided and curing etc. complete. (Excluding reinforcement and structural steel).with fully automatic micro processor based PLC with SCADA enabled reversible Drum Type mixer/ concrete Batch mix plant (Pan mixer) etc. complete. With natural sand/V.S.I. quality Artificial Sand
1006Providing and laying Cast in situ/Ready Mix cement concrete M-25 of trap/ granite / quartzite/ gneiss metal for R.C.C. slabs and landingsas per detailed designs and drawings including centering, formwork, cover blocks, compaction, finishing the formed surfaces with cement mortar 1:3 of sufficient minimum thickness to give a smooth and even surface or roughening if special finish is to be provided and curing etc. complete.(Excluding reinforcement and structural steel).with fully automatic micro processor based PLC with SCADA enabled reversible Drum Type mixer/ concrete Batch mix plant (Pan mixer) etc. complete. With natural sand/V.S.I. quality Artificial Sand
1007Providing and fixing in position TMT - FE - 500 bar reinforcement of various diameters for R.C.C. pile caps, footings, foundations, slabs, beams columns, canopies, staircase, newels, chajjas, lintels pardis, copings, fins, arches etc. as per detailed designs, drawings and schedules. including cutting, bending, hooking the bars, binding with wires or tack welding and supporting as required complete.
1008TOTAL REINFORCED CEMENT CONCRETE WORK
1009BRICK WORK
1010Providing second class Burnt Brick masonry with conventional/ I.S. type bricks in cement mortar 1:6 in foundations and plinth of inner walls/ in plinth external walls including bailing out water manually , striking joints on unexposed faces, raking out joints on exposed faces and watering etc. Complete.
1011Providing second class Burnt Brick masonry with conventional/ I.S. type bricks in cement mortar 1:6 in superstructure including striking joints, raking out joints, watering and scaffolding etc. Complete
1012Providing second class Burnt Brick masonry with conventional/ I.S. type bricks in cement mortar 1:4 in half brick thick wall including mild steel longitudinal reinforcement of 2 bars of 6 mm diameter / 2 hoop iron strips 25 mm X 1.6 mm placedat every third course, properly bent and bonded at ends scaffolding, racking out joints and watering etc. complete.
1013Brick edging 7cm wide 11.4 cm deep to plinth protection with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 including grouting with cement mortar 1:4 (1 cement : 4 fine sand).
1014TOTAL BRICK WORK
1015MARBLE & GRANITE WORK
1016Providing and fixing machine cut mirror polished 18 mm to 20 mm thick telephone black / Amba White / Cat bary brown / RBI red / Ocean Brown granite stone partition with rounding the edgesetc. complete. One side polish
1017Extra for providing opening of required size & shape for wash basins/ kitchen sink in kitchen platform, vanity counters and similar location in marble/Granite/Stone work including necessary holes for pillar taps etc. including rubbing and polishing of cut edge etc. complete.
1018TOTAL MARBLE & GRANITE WORK
1019STEEL WORK
1020Providing and fabricating structural steel work in rolled sections like joists, channels, angles, tees etc. as per detailed design and drawings or as directed including cutting, fabricating, hoisting, erecting, fixing in position making riveted / bolted /welded connections without connecting plates, braces etc. and including one coat of anticorrosive paint and over it two coats of oil painting of approved quality and shade etc. complete.
1021Providing structural steel work in trusses, other similar trussed purlins and members with all bracing, gusset plates etc. as per detailed designs and drawings or as directed including cutting, fabricating, hoisting, erecting fixing in position, Making riveted/ bolted/ welded connection and one coat of anticorrosive paint and over it 2 coats of oil painting approved quality and shade etc. complete.
1022Providing and Fixing mat finish stainless steel (of 302 grade ) railing with toppipe of 50 mm dia. and vertical pipe of 38 mm dia at 0.60 m c/c or as required and horizontal pipes of 25 mm dia in three rows, all pipes of 2 mm thick including buffing,fabricating fixtures and fastening including pipe base of appropriate diameter and ball base of 75 mm dia above newel post of 75 mm diameter etc. complete (Prior approval of sample and brand by Ex.Engineer is necessary before use)
1023TOTAL STEEL WORK
1024FLOORING WORK
1025Providing and laying cement concrete flooring 40 mm thick with M15 cement concrete laid to proper level and slope in alternate bays including compaction, filling joints, marking lines to give the appearance of tiles of 30 cm x 30 cm or other size laid diagonally /square etc finishing smooth (with extra cement) in any colour as directed and curing etc.complete. With Natural Sand
1026Providing and laying machine cut machine Polished Kota stone flooring 25mm to 30mm thick and required width in plain/ diamond pattern on bed of 1:6 C. M. including cement float, filling joints with neat cement slurry, curing, polishing and cleaningetc. complete.
1027Providing and fixing in required position skirting or dado of polished Kotah Stone slab 25mm to 30mm thick fixed on base on plaster of cement mortar 1:4 including cement float, filling joints with cement slurry, curing rubbing, polishing and cleaning complete.
1028Providing and laying machine cut machine polished machine cut Kota stone slabs 20 to 25 mm thick for treads and risers of steps and staircases, with rounded nosing for the treads on a bed of 1:4 cement mortar including cement float, filling joints with neat cement slurry, curing, polishing and cleaning etc. complete.
1029Providing and laying vitrified mirror / glossy finish tiles decorative typehaving size 590 mm to 605 mm x 590 mm to 605 mm of 8 to 10 mm thickness and confirming to IS. 15622-2006 ( group Bla) of approved make, shade and pattern for flooring in required position laid on a bed of 1:4 cement mortar including neat cement float, filling joints, curing and clearingetc. complete. a) Flooring
1030Providing and laying vitrified mirror / glossy finish tiles having size 590 mm to 605 mm x 590 mm to 605 mm of 8 to 10 mm thickness and confirming to IS. 15622-2006 ( group Bla) of approved make, shade and pattern for flooring in required position laid on a bed of 1:4 cement mortar including neat cement float, filling joints, curing and clearingetc. complete.b) Skirting
1031Providing and laying ceramic tileshaving size 30 cm. x 45 cm. confirming to corresponding I.S. for dado and skirting in required position with readymade adhesive mortar of approved quality on plaster of 1:2 cement mortar including joint filling with white/ colour cement slurry cleaning curing etc. complete.
1032Providing and laying Antiskid Ceramic tiles of approved qualityof size 30 cm x 30 cm and confirming to IS 15622-2006 (Group-B IIA) for antiskid flooring in required position laid on a bed of 1:4 cement mortar including cement float, filling joint with cement slurry cleaning curing etc. complete.
1033TOTAL FLOORING WORK
1034ROOFING
1035Providing and fixing plain zinc sheeting of 0.80 mm thick (22 B.W.G.) over the ridge hip or valley to galvanized iron sheet roofing including all fastening and bolt galvanised iron screws and bolts, lead and bitumen washers etc. complete.(Weight of 6.8 kg/sq.m.).
1036Providing and fixing precoated galvanised steel sheet roofing accessories 0.50 mm (+ 0.05 %) total coated thickness, Zinc coating 120 grams per sqm as per IS: 277, in 240 mpa steel grade, 5-7 microns epoxy primer on both side of the sheet and polyester top coat 15- 18 microns using self drilling/ self tapping screws complete :
1037Ridges plain (500 - 600mm)
1038Barge board (Upto 300 mm)
1039Gutter (600 mm over all girth)
1040Providing and fixing in position Gypsum board false ceiling with 12.5mm thick Gypsum boards, screwed /fixed to the under structure of suspended G.I.Grid constructed and suspended from the main ceiling consisting of ceiling sections of size 25x50mm maximum center to center distance of 600 milimetre perimeter channel and intermediate channels at maximum center to center distance 1200 milimetre galvanized grid should be fixed to reinforced cement concrete slab. The gypsum board should be fixed to galvanized iron grid with necessary screws. The boards should be taped and filled from under side to give smooth, seamless ceiling. The rate should include necessary additional ceiling sections and intermediate channels. Additional intermediate channels should be fixed to strap hangers for additional support to prevents trap pin gate very 1200 milimetre item to be completed in all respect including necessary sleeves for ducts finishing of joints cutouts, painting includinglabour,material,liftsetc.all complete.
1041TOTAL ROOFING
1042FINISHING WORK
1043Providing internal cement plaster 12mm thick in single coat in cement mortar 1:4 without neeru finish to concrete or brick surfaces, in all positions including scaffolding and curing etc. complete.
1044Providing rough cast cement plaster externally in two coats to concrete,brick or stone masonry surfaces in all positions with base coat of 12 to 15mm thick in C.M.1:4 and rough cast treatment 12mm thick in proportion 1:11/2:3 including scaffolding and fourteen days curing complete.
1045Labour charges for providing groove in external plaster having width and spaced as directed by engineer incharge etc. complete.
1046Providing internal cement plaster 6 mm thick in a single coat in cement mortar 1:3 without neeru finish to concrete surface in all positions including scaffolding and curing etc. complete.
1047Providing and fixing chicken mesh of 22 gauge, with about 30 cm. width at the junction of R.C.C members and brick work, of approved quality including fixing mesh in position by necessary drilling in concrete /B.B.masonry and or tying by binding wire etc. complete.
1048Providing and applying washable oil-bound distemper of approved colour and shade to old and new surfaces in two coats including scaffolding, preparing the surfaces. (excluding the primer coat.) etc. complete.
1049Providing and applying priming coat on concrete/ masonary/ Asbestos Cement plastered surfaces including scaffolding if necessary, preparing the surface by thoroughly cleaning oil, grease, dirt and other foreign matter and sand papering as required etc. complete.
1050Providing and applying two coats of textured synthetic paint of approved shade and quality and one coat of primer before applying textured paint including scaffolding if necessary preparing surface by thoroughly cleaning oil, grease, dirt and other materials as required, etc. complete.
1051Providing and applying plastic emulsion paint of approved quality, colour and shade to old and new surfaces in two coats including scaffolding, preparing the surface. (excluding the primer coat)etc. complete.
1052Providing and applying Two coats of wall care Putty of 2mm thickness for plastered surface and 5-6mm thickness finished concrete surface to Ceiling and Walls to prepare surface even and smooth of Brands BIRLA WHITE, BERGER, BISION, J.K., make, etc complete.a) For plastered walls/ceiling 2mm
1053Providing and applying two coats of synthetic enamel paint of approved colour to new /old structural steel work and wood work in buildings, including scaffolding if necessary, cleaning and preparing the surface (excluding primer coat) etc. complete.
1054TOTAL FINISHING WORK
1055ALUMINIUM WORK
1056Providing and fixing in position aluminium partly openable and partly fixed window of any size as per detailed drawing and as directed by Engineerincharge with all necessary alluminium sections including necessary fixtures and fastening with 5 mm thick float glass etc. complete. b) With powder coating Note While arriving at the rate of item of item weight at 6.90 kg/Sqm is considered.
1057Providing and fixing in position, Double shuttered aluminium extruded powder coated openable door of specified size with aluminium door frame of powder coated section 101.60 x 44.75mm , 3.18 mm thick and shutter comprising of powder coated section having bottom and lock rail of size 150 mm x 44.5 mm x 3.00 mm thick top rails 47.62 x 44.45 mm x 3.00 mm thick , vertical style 47.62 x 44.45 mm, 3.00 mm thick and for shutter plain glass panes 5 mm thick for top panels and 12mm thick both side laminated phenol bonded particle board panels for bottom panels etc. , I.S.I. mark , heavy duty, Hydraulic floor spring of 150 kg capacity , having heavy duty concealed lock, necessary beading, glazing clips, PVC gaskets, 250mm length aluminium tower bolts, 150mm dia. pad handle, etc. as per detailed design and drawing or as directed by engineer in charge including all materials , labours, and equipment etc.complete
1058Providing and fixing in position, Single shuttered aluminium extruded powder coated openable door of overall size 0.9mx2.4m with aluminium door frame of powder coated section 101.60 x 44.75mm , 3.18 mm thick and shutter comprising of powder coated section having bottom and lock rail of size 150 mm x 44.5 mm x 3.00 mm thick top rails 47.62 x 44.45 mm x 3.00 mm thick , vertical style 47.62 x 44.45 mm, 3.00 mm thick and for shutter plain glass panes 5 mm thick for top panels and 12mm thick both side laminated phenol bonded particle board panels for bottom panels etc. , I.S.I. mark , heavy duty, Hydraulic floor spring of 150 kg capacity , having heavy duty concealed lock, necessary beading, glazing clips, PVC gaskets, 250mm length aluminium tower bolts, 150mm dia. pad handle, etc. as per detailed design and drawing or as directed by engineer in charge including all materials , labours, and equipment etc.complete
1059TOTAL ALUMINIUM WORK
1060TOTAL CIVIL WORK
1061ELECTRICAL WORKS
1062SUBHEAD- I:DISTRIBUTION BOARD
1063Supplying & erecting triple pole and neutral distribution board (TPNDB) with door surface/ flush mounted suitable for 3 pole MCCB as incomer & outgoing SP MCB (24 poles) or TP MCB of 8 ways (24 poles) , on iron/ GI frame. (vertical busbar type) as per specification no. SW-SWR/MCBDB1
1064Supplying erecting and marking four pole isolators only switch version of miniature circuit breakers of 63A in provided distribution board complete.
1065Supplying, erecting & marking SPMCB 6A to 32A, C-series (for motor/power) in provided distribution board as per specification no. SW-SWR/MCB
1066Supplying, erecting & marking SPMCB 6A to 32A, B- series (for lighting) in provided distribution board as per specification no. SWSWR/ MCB
1067Providing, erecting and commissioning 2 pole RCCB only of electromagnetic type with 30/100/300 mA sensitivity and having capacity of 63A complete as per specification no. SWRCCB/ RCCB
1068TOTAL SUB HEAD-I
1069SUB-HEAD - II: INTERNAL WIRING
1070Point wiring for light/fan/bell hybrid type (Surface type under false ceiling and concealed type for drops & switch boards on walls) in min 20 mm PVC conduit / casing n capping with 1.5 sq.mm. (2+1E) FR grade copper wires, modular type switch, earthing and required accessories as per specification No: WGPW/ HW
1071Secondary point wiring for additional light/ bell point, concealed type in min 20 mm PVC conduit with 1.5 sq.mm. (2+1E) FR/FRLSH grade copper wires with required accessories as per specification No: WG-PW/CW
1072Supplying & erecting mains with 3x2.5 Sq.mm F.R copper PVC insulated wire laid in provided conduit/trunking/inside pole/Bus bars or any other places as per specification No: WGMA/ BW
1073Supplying & erecting mains with 3x4 sq.mm FR copper PVC insulated wire laid in provided conduit/trunking/inside pole/Bus bars or any other places as per specification No: WGMA/ BW
1074Supplying & erecting mains with 3x6 sq.mm F.R copper PVC insulated wire laid in provided conduit/trunking/inside pole/Bus bars or any other places as per specification No: WGMA/ BW
1075Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed steel conduit as required
10764 x 10 sq.mm + 2 x 6sq.mm. earth wire
1077Supplying and erecting ISI mark modular type switch 6A / 10A duly erected on provided plate and box with wiring connections complete.
1078Supplying and erecting ISI mark modular type 5 pin socket with safety shutters 3 module socket 6A 240V AC supply, duly erected on provided plate and box with wiring connections complete duly erected
1079Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 6 pin 5/6 & 15/16 amps modular socket outlet and 15/16 amps modular switch, connection etc. as required.
1080Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providng and fixing 2 nos. 3 pin 5/6 A modular socket outlet and 2 nos. 5/6 A modular switch, connections etc. as required. (For light plugs to be used in non residential buildings).
1081Supplying & erecting original 1.25 mm CRCA sheet metal enclosures with 20A. 2 pin plug & earth socket and 20A. 3 pin plug top with 20A/30A single pole MCB complete erected on angle iron/ GI frame.
1082Supplying and erecting electronic type step regulator for ceiling fan 600/ 900/ 1200/ 1400 mm. sweep, complete erected on provided switch board.
1083Providing & erecting Hot dipped galvanized perforated type cable tray manufactured from 16 swg (1.6 mm thick) GI sheet of 200 mm width & 75 mm height complete with necessary coupler plates & hardware in approved manner.
1084TOTAL SUB HEAD-II
1085SUB-HEAD III - FANS & LIGHT FIXTURES:
1086Supplying & erecting LED 20W tube light fitting (4 feet) with aluminium housing, heat sink, integrated HF electronic driver complete
1087Supplying and erecting LED square / circular 13 to 15W down lighter having pressure die-cast aluminum housing, opal translucent cover, mounting arrangement with board for surface type or spring loaded mounting clips for flush type complete.
1088Supplying and erecting LED square / circular 16 to 20W down lighter having pressure die-cast aluminium housing, opal translucent cover, mounting arrangement with board for surface type or spring loaded mounting clips for flush type complete
1089Supplying and erecting LED Mirror Light with integrated driver including 7W to 9W lamp with polycarbonate housing and opal diffuser to be fixed above mirror or as required on clamps complete..
1090Supplying and erecting regular/ standard model ceiling fan of 1400mm. sweep complete erected in position as per specification no. FG-FN/CF
1091Supplying and erecting fresh air cum exhaust fan of light duty 250 V A.C. 50 cycles 300mm. 1400 RPM rust proof body & blades, wire mesh, duly erected in an approved manner.
1092Supplying and erecting decorative oval bulk head edge-lit 10W LED luminaire comprising of high brightness LED Fitting on provided PVC block / wooden board.
1093TOTAL SUB HEAD-III
1094SUB HEAD-IV : T.V. , TELEPHONE, DATA SYSTEM, CONDUITING andLAN SYSTEM
1095Supplying and erecting PVC trunking (PVC casing-ncapping) of size 20 mm with accessories on wall/ceiling as per specification No: WG-MA/CON.
1096Supplying and erecting ISI mark modular type T.V. socket single outlet, duly erected on provided plate and box with wiring connections complete.
1097Supplying & installing co-axial copper cable low voltage grade RG-6 as per specification No. WG-TW
1098Supplying and fixing M.S. box with Phenolic laminate plate 4- way splitter box for TV antennacomplete as required.
1099Supplying and fixing of 1 or 2 module (75mm x75mm) size GI boxes with modular base and cover plate for modular switches in recess etc complete as required
1100TOTAL SUB HEAD-IV
1101Sub-Head - V -CCTV AND PA SYSTAM
1102Video Surveillance System(IP CCTV)
1103Supplying, installation, testing and commissioning of 2 megapixels resolution Network Dome Camerafor true HD quality images,2.8 – 12 mm varifocal lens,True Day/Night (TDN) functionality for true color image ,Motion Detection 4 Zones, Multi- Level Sensitivity Privacy Zones 4 Zones,SnapshootSupport JPEG format Password Protection Support Character Display Support(Channel /Date) ONVIF Yes,IR Illumination20-30M IR illuminators for clear images in low light conditions Wide Dynamic Range 3D noise reduction for sharper images and lower bandwidth use in low lightONVIF compliant complete in all respect.Make-Tyco/Mobotix/Pelco.
1104Supply, installation, testing & commissioning of 12 Port PoE+ Switch with 2 SFP slots 12 x 10/100/1000 Base-T PoE+ ports and additional 2 100/1000X SFP PORTS Should support PoE+ as per IEEE 802.3 at with PoE budget of 100W.Should support STP, RSTP, MSTP, IGMP v1/v2/v3 snooping, STP root guard, Voice VLAN, MLD snooping (MLDv1 and v2), IEEE 802.3ac VLAN tagging IEEE 802.17/equivalent for sub 50ms ring protection in following scenario : single, dual fibre cuts in ring and when fibre cut at common shared link in between two or more rings.
1105Supply, Installation, Testing & Commissioning of 9U Rack with specifications as follows: Width x Depth: 550mm(width) * 500mm (Depth); Height: 9U; Ventilation: Fan 90CFM 230V AC fitted on rack top; Provisions:Front toughened glass with lock and key; Wiring: 1U Cable Manger Metal with PVC Loop; Cable Manager: On bottom of Rack; Power Distribution: PDU 6 Point 5Amp Socket, indian round pin with power Cable; Accessories : Mounting hardware packet of 10 piece.
1106Supplying and fixing of HDMI Cable 3 mtrs length.
1107Network Wiring for Cameras/devices with CAT 6e cable from NVR in exposed / recessed 25 mm dia MS Conduit including termination and providing/fixing 1.2 mm thick GI box with grid plates with earthing complete in all respect.
1108Power wiring for Cameras/devices with 3 x 1.5 sq mm FRLS wire in exposed / recessed 25 mm dia MS Conduit including termination and providing/fixing 1.2 mm thick GI box with grid plates with earthing complete in all respect.
1109TOTAL SUB HEAD -V
1110Sub-Head -VI- MISCELLANEOUS ITEMS CABLE & SAFETY CHART
1111Supplying, erecting & terminating XPLE armoured cable 4 core 16 sq. mm. aluminium conductor with continuous 5.48 sq. mm. (12 SWG) G.I. earth wire complete erected with glands & lugs, on wall/ trusses/pole or laid in provided trench/ pipe as per specification no. CB-LT/AL
1112Providing & erecting epoxy outdoor / indoor end termination kit for LT XLPE armoured cable 2.5 to 16 sq. mm. cable, with necessary material as per specification no. CB-JT/LT
1113Supplying and laying (including excavation of suitable width & depth up to 90 cm) 200 mm outside dia, double wall corrugated pipes (DWC) of HDPE for enclosing cable below ground/road surface, to required depth complete.
1114TOTAL SUB HEAD-VII
1115SUB-HEAD -VII: EARTHING
1116Providing earthing with galvanized iron earth plate size 60 x 60 x 0.6 cm complete with all materials, testing & recording the results as per specification no. EA-EP
1117Supplying and erecting GI earth wire of high purity of different sizes used for earthing or any other purposes on wall with necessary G. I. Clamps fixed on wall/cable/ conduit with screws in an approved manner.
1118TOTAL SUB HEAD-VII
1119TOTAL ELECTRICAL WORK
1120EXTERNAL PLUMBING WORKS FOR COMMON TOILET
1121(EXTERNAL SEWERAGE SYSTEM)
1122Earth work in excavation by mechanical means (hydraulic excavator)/manual means over areas (exceeding 30cm in depth. 1.5m in width as well as 10 sqm on plan) including disposal of excavated earth, lead upto 50m and lift upto 1.5m; disposed earth to be levelled and neatly dressed.
1123Providing, laying and jointing glazed stoneware pipes class SP-1 with stiff mixture of cement mortar in the proportion of 1:1 (1 cement : 1 fine sand) including testing of joints etc. complete :
1124150 mm diameter
1125200 mm diameter
1126250 mm diameter
1127Providing and laying cement concrete 1:5:10 (1 cement : 5 coarse sand : 10 graded stone aggregate 40 mm nominal size) all-round S.W. pipes including bed concrete as per standard design :
1128150 mm diameter S.W. pipe
1129200 mm diameter S.W. pipe
1130250 mm diameter S.W. pipe
1131Providing and laying cement concrete 1:5:10 (1 cement : 5 coarse sand : 10 graded stone aggregate 40 mm nominal size) up to haunches of S.W. pipes including bed concrete as per standard design :
1132150 mm diameter S.W. pipe
1133200 mm diameter S.W. pipe
1134250 mm diameter S.W. pipe
1135Providing and fixing square-mouth S.W. gully trap class SP-1 complete with C.I. grating brick masonry chamber with water tight C.I. cover with frame of 300 x300 mm size (inside) the weight of cover to be not less than 4.50 kg and frame to be not less than 2.70 kg as per standard design:
1136180x150 mm size P type
1137With Sewer bricks conforming to IS : 4885
1138Constructing brick masonry manhole in cement mortar 1:4 ( 1 cement : 4 coarse sand ) with R.C.C. top slab with 1:1.5:3 mix (1 cement : 1.5 coarse sand (zone- III) : 3 graded stone aggregate 20 mm nominal size), foundation concrete 1:4:8 mix (1 cement : 4 coarse sand (zone- III) : 8 graded stone aggregate 40 mm nominal size), inside plastering 12 mm thick with cement mortar 1:3 (1 cement : 3 coarse sand) finished with floating coat of neat cement and making channels in cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) finished with a floating coat of neat cement complete as per standard design :
1139Inside size 90x80 cm and 45 cm deep including precast RCC Cover with frame (light duty) 455x610 mm internal dimensions, total weight of cover and frame to be not less than 38 kg (weight of cover 23 kg and weight of frame 15 kg) :
1140With Sewer bricks conforming to IS : 4885
1141Inside size 120x90 cm and 90 cm deep including C.I. cover with frame (heavy duty) 560 mm internal diameter, total weight of cover and frame to be not less than 208 kg (weight of cover 108 kg and weight of frame 100 kg)
1142With Sewer bricks conforming to IS : 4885
1143Extra for depth for manholes :
1144Size 90x80 cm
1145With Sewer bricks conforming to IS : 4885
1146Size 120x90 cm
1147With Sewer bricks conforming to IS : 4885
1148Providing orange colour safety foot rest of minimum 6 mm thick plastic encapsulated as per IS : 10910, on 12 mm dia steel bar conforming to IS: 1786, having minimum cross section as 23 mmx25 mm and over all minimum length 263 mm and width as 165 mm with minimum 112 mm space between protruded legs having 2 mm tread on top surface by ribbing or chequering besides necessary and adequate anchoring projections on tail length on 138 mm as per standard drawing and suitable to with stand the bend test andchemical resistance test as per specifications and having manufacture’s permanent identification mark to be visible even after fixing, including fixing in manholes with 30x20x15 cm cement concrete block 1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size) complete as per design.
1149Making connection of drain or sewer line with existing manhole including breaking into and making good the walls, floors with cement concrete 1:2:4 mix (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) cement plastered on both sides with cement mortar 1:3 (1 cement : 3 coarse sand), finished with a floating coat of neat cement and making necessary channels for the drain etc. complete :
1150For pipes 250 to 300 mm diameter
1151TOTAL (EXTERNAL SEWERAGE SYSTEM) C/F TO SUMMARY
1152(EXTERNAL STORM WATER SYSTEM)
1153Earth work in excavation by mechanical means (hydraulic excavator)/manual means over areas (exceeding 30cm in depth. 1.5m in width as well as 10 sqm on plan) including disposal of excavated earth, lead upto 50m and lift upto 1.5m; disposed earth to be levelled and neatly dressed.
1154Providing and laying non-pressure NP2 class (light duty) R.C.C. pipes with collars jointed with stiff mixture of cement mortar in the proportion of 1:2 (1 cement : 2 fine sand) including testing of joints etc. complete :
1155150 mm dia. R.C.C. pipe
1156250 mm dia. R.C.C. pipe
1157300 mm dia. R.C.C. pipe
1158Constructing brick masonry road gully chamber 50x45x60 cm with bricks in cement mortar 1:4 (1 cement : 4 coarse sand) including 500x450 mm pre-cast R.C.C. horizontal grating with frame complete as per standard design :
1159With common burnt clay F.P.S. (non modular) bricks of class designation 7.5
1160Providing and laying Non Pressure NP-3 class (Medium duty) R.C.C. pipes including collars/spigot jointed with stiff mixture of cement mortar in the proportion of 1:2 (1 cement : 2 fine sand) including testing of joints etc. complete
1161450 mm dia RCC pipes
1162Making connection of drain or sewer line with existing manhole including breaking into and making good the walls, floors with cement concrete 1:2:4 mix (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) cement plastered on both sides with cement mortar 1:3 (1 cement : 3 coarse sand), finished with a floating coat of neat cement and making necessary channels for the drain etc. complete :
1163For pipes 250 to 300 mm diameter
1164Total (EXTERNAL STORM WATER SYSTEM) C/F TO SUMMARY
1165(EXTERNAL DOMESTIC WATER SYSTEM)
1166Providing and fixing G.I. pipes complete with G.I. fittings including, trenching and refilling etc. external works
116732 mm dia nominal bore
1168Painting G.I. pipes and fittings with two coats of anti-corrosive bitumastic paint of approved quality :
116932 mm dia nominal bore
1170Providing and filling sand of grading zone V or coarser grade all-round the G.I. pipes in external work.
117132 mm dia nominal bore
1172Providing and fixing gun metal gate valve with C.I. wheel of approved quality
1173(screwed end) :
117432mm nominal bore
1175Constructing masonry Chamber 60x60x75 cm inside, in brick work in cement mortar 1:4 (1 cement : 4 coarse sand) for sluice valve, with C.I. surface box 100mm top diameter, 160 mm bottom diameter and 180 mm deep ( inside) with chained lid and RCC top slab 1:2:4 mix (1 cement : 2 coarse sand : 4 graded stone aggregate 20mm nominal size ) , i/c necessary excavation, foundation concrete 1:5:10 (1 cement : 5 fine sand : 10 graded stone aggregate 40 mm nominal size) and inside plastering with cement mortar 1:3 (1 cement : 3 coarse sand) 12 mm thick, finished with a floating coat of neat cement complete as per standard design :
1176With common burnt clay F.P.S.(non modular) bricks of class designation 7.5
1177TOTAL (EXTERNAL DOMESTIC WATER SYSTEM) C/F TO SUMMARY
1178TOTAL EXTERNAL PLUMBING COST
1179INTERNAL PLUMBING
1180SANITARY INSTALLATIONS
1181Providing and fixing European type white glazed earthenware coupled closet symphonic trap with symphonic low level white glazed 10 litres cistern with black backlite seat with all necessary pipe connection etc. complete.
1182Providing and fixing Hand shower (health faucet) with 8mm dia. 1m long flexible tube having wall hook with approved make including necessary sockets/ union nut etc. complete as directed by Engineer in charge.
1183Providing and fixing White glazed with bottle trap earthenware Wash Hand Basin of 55x40 cm size including cold water piller taps, brackets, rubber plugs and brass chain, stop tap, chromium plate bottle trap and necessary pipe connections including UPAC waste pipe and trap upto the outside face of the wall, making good the damaged surface, testing etc. complete.
1184Providing and fixing C.P. BIB cock with wall flange of approved make including necessary sockets/ union nut etc. complete as directed by Engineer in charge.
1185Providing and fixing white glazed urinal of size 710x460x300mm with sensotronic concealed type flushing valve for urinal with complete kit having fittings, inlet pipe with stop tap, brackets for fixing the cistern, 32mm diameter P.V.C. flush pipe with fitting and flushing arrangement including lead soil pipe, lead trap & soil pipe connection upto the outside face of wall etc complete.
1186Providing and fixing C.P. Angular stop clock with wall flange of approved make continental including necessary sockets/union nut etc. complete.
1187Providing and fixing PTMT liquid soap container 109 mm wide, 125 mm high and 112 mm distance from wall of standard shape with bracket of the same materials with snap fittings of approved quality and colour, weighing not less than 105 gms.
1188Providing and fixing uplasticised PVC connection pipe with brass unions :
118945 cm length
119015 mm nominal bore
1191TOTAL SANITARY INSTALLATIONS
1192INTERNAL SEWERAGE & DRAINAGE
1193Supplying installation testing and commissoning of Hubless centrifugally cast iron pipes as per ISI 15905 equivalent to NECO inclusive of all necessary special fitting like bends, tees, and caps, "Y" bends for cleaning offsets, junctions, cowls, etc. lad under floor/fixed on walls and in pipe shafts etc. complete. The quoted rate should include lead and lifting charges to all levels, necessary scaffolding and supports like hanger supports grip bolts and CV sheet 304 grade clamps etc. with prior approval of concerned Superitending Engineer.
1194100 mm dia
1195Providing and fixing on walls/ ceiling/ floors, 32 mm dia. heavy grade having embossed as ISI Mark galvanised iron pipes weight of 3.89 Kg/meter with necessary fittings . remaking good the demolished portion and applying primer of anti-corrosive oil paint 2 coats Including necessary scaffolding and removing existing pipe line if necessary and conveying and stacking the same in PWD chowky or as directed etc. complete.
1196Providing and fixing on walls/ ceiling/ floors, 40 mm dia. heavy grade having embossed as ISI Mark galvanised iron pipes weight of 4.49 Kg/meter with necessary fittings and remaking good the demolished portion and applying primer of anti-corrosive oil paint 2 coats Including necessary scaffolding and removing existing pipe line if necessary and conveying and stacking the same in PWD chowky or as directed etc. complete.
1197Providing and fixing on walls/ ceiling/ floors, 50 mm dia heavy grade having embossed as ISI Mark galvanised iron pipes weight of 6.33 Kg/meter with necessary fittings.and remaking good the demolished portion and primer of anti corrossive oil paint 2 coats Including necessary scaffolding and removing existing pipe line if necessary and conveying and stacking the same in PWD chowky or as directed etc. complete.
1198Providing and fixing 10cm C.I. Nahani Trap including C.I. grating bend and piece of C.I. pipe upto the outside face of the wall complete.
1199Providing and fixing P.V.C. Rain water pipes of 110mm outer diameter and having wall thickness of 2.2 to 2.7 mm confirming to I.S. 13592- 1992 including proper rainwater receiving recess with P.V.C. plug, bend, necessary fittings, such as, offsets, shoes, inluding fixing the pipe on wall using approved wooden cleats projecting 25mm to 40mm from face of wall a fixing with clips of approved quality and number ,filing the joint using rubber gasket with solvent cement and properly resting the shoe of pipes on C.C. or masonry blocks, including necessary scaffolding and maintenance for 3 yrs for any leakages or dislocations of pipes. All the P.V.C. fittings and additional 2 piece socket clips shall be got approved from engineer in charge etc. complete.
1200Providing and fixing to the inlet mouth of rain water pipe cast iron grating 15 cm diameter and weighing not less than 440 grams.
1201Providing and fixing Ductile iron Man Hole Covers/ Strom Water Grating and Grating with frame of Various sizes, weight and types and load bearing capacity as per EN-124, equivalent NECO with prior approval of concerned Superitending Engineer.
1202Total C/F to Summary
1203INTERNAL WATER SUPPLY
1204Providing and fixing on walls/ ceiling/ floor 15 mm dia. CPVC pipe with necessary fittings, remaking good the demolished portion etc. complete. Including removing existing pipe line if necessary and conveying and stacking the same in PWD chowky or as directed etc. complete.
1205Providing and fixing on walls/ceiling/floor 20 mm dia. CPVC pipe with necessary fittings, remaking good the demolished portion etc. complete. Including removing existing pipe line if necessary and conveying and stacking the same in PWD chowky or as directed etc. complete.
1206Providing and fixing on walls/ ceiling/ floor 25 mm dia. CPVC pipe with necessary fittings, remaking good the demolished portion etc. complete. Including removing existing pipe line if necessary and conveying and stacking the same in PWD chowky or as directed etc. complete.
1207Providing and fixing on walls/ ceiling/ floor 32 mm dia. CPVC pipe with necessary fittings, remaking good the demolished portion etc. complete. Including removing existing pipe line if necessary and conveying and stacking the same in PWD chowky or as directed etc. complete.
1208Providing and fixing on walls /ceiling/ floor 40 mm dia. CPVC pipe with necessary fittings, remaking good the demolished portion etc. complete. Including removing existing pipe line if necessary and conveying and stacking the same in PWD chowky or as directed etc. complete.
1209Providing and fixing on walls/ ceiling/ floors, 40 mm dia. heavy grade having embossed as ISI Mark galvanised iron pipes weight of 4.49 Kg/meter with necessary fittings and remaking good the demolished portion and applying primer of anti-corrosive oil paint 2 coats Including necessary scaffolding and removing existing pipe line if necessary and conveying and stacking the same in PWD chowky or as directed etc. complete.
1210Providing and fixing on walls/ ceiling/ floors, 50 mm dia heavy grade having embossed as ISI Mark galvanised iron pipes weight of 6.33 Kg/meter with necessary fittings.and remaking good the demolished portion and primer of anti corrossive oil paint 2 coats Including necessary scaffolding and removing existing pipe line if necessary and conveying and stacking the same in PWD chowky or as directed etc. complete.
1211Providing and fixing on walls/ ceiling/ floors, 50 mm dia heavy grade having embossed as ISI Mark galvanised iron pipes weight of 6.33 Kg/meter with necessary fittings.and remaking good the demolished portion and primer of anti corrossive oil paint 2 coats Including necessary scaffolding and removing existing pipe line if necessary and conveying and stacking the same in PWD chowky or as directed etc. complete.
1212Providing and fixing gun metal gate valve with C.I. wheel of approved quality (screwed end) :
121325 mm nominal bore
121440 mm nominal bore
121550 mm nominal bore
121665 mm nominal bore
1217Providing and fixing ball valve (brass) of approved quality, High or low pressure, with plastic floats complete :
121832 mm nominal bore
121940 mm nominal bore
122050 mm nominal bore
1221Prividing and Fixing automatic "NO-Touch " electric hand-driers complete with all accessories & fittings. (Make: Jaquar Model No. HDR-SAP-M99ACS)
1222Providing and fixing Water cooler with inbuilt RO and storage complete including fixing in position.
1223Providing and fixing H.D.P container Syntex or alike one piece moulded water tank made out of low density polythyler and built corrugation including of delivery up to destination hoisting and fixing of accessories such as inlet, outlet overflow of all tanks capacity above 1000 to 20,000 litres.
1224Total INTERNAL WATER SUPPLY
1225TOTAL OF INTERNAL PLUMBING
1226PART-C TOTAL OF TOILETBUILDING(3 nos.)
1227PART-D SPORTS WORK
1228Open GYM
1229EARTH WORKS:
1230Clearing grass, removal of rubbish up tp a distance of 50m outside the periphery of area
1231Excavation for roadway in earth, soil of all sorts, sand gravel, or soft murum including dressing section to the required grade, camber and isde slopes and conveying the excavated materials with all lifts upto a lead of 50m and spreading for embackment or stacking as directed.
1232Supply and stacking of good earth
1233DRAINAGE & TOE WALL WORKS
1234Providing and laying in position cement concrete M10 grade
1235Providing and laying in position cement concrete M15 grade
1236First class Brick work cement mortor 1:6
123712 mm cement plaster of mix :
1238providing and fixing of precast Rcc perforated drain cover of size 600 mm x600mm x75mm . With M30 Grade concrete and reinforcement 8 mm steel @ 100mm c/c. For easy flow of water.
1239ROAD WORKS:
1240Consolidation of subgrade with power road roller of 8 to 12 tonne capacity to required slopeincludingmaking goodtheundulations etc. with earth or quarry spoils etc.and rerolling the subgrade.
1241Construction of stabilised soil base with organo silance by providing lpcally available morum/soil 70% mixed with 30% granular sub-base
1242With material conforming to Grade-II (size range 53 mm to 0.075 mm ) having CBR Value-25
1243Providing, laying, spreading and compacting graded stone aggregate (size range 53 mm to 0.075 mm ) to wet mix macadam (WMM) specification including premixing the material with water at OMC in mechanical mix plant, carriage of mixed material by tipper to site,for all leads & lifts, laying in uniform layers with mechanical paver finisher in sub- base / base course on well prepared surface and compacting with vibratory roller of 8 to 10 tonne capacity to achieve the desired density, complete as per specifications and directions of Engineer-in-Charge.
1244Providing and applying primer coat
1245Providing and applying tack coat
1246Providing and laying Dense Bituminous macadam on prepared surface with specified graded crushed stone aggregate for profile corrective base/binder course including loading of aggregate with FE loader and hot mixing of stone aggregates and bitumen in hot mix plant, transporting the mixed material by tipper to paver and laying the mixed materialwith paver finisher fitted with electronic sensing deviceto the required level and grade androlling by road roller as per MORTH specifications, to achieve the desired density and compaction, but excluding the cost of primer /tack coat.
12474.5% bitumen
1248Providing and laying bituminous concreteon theprepared surface with specified graded crushed stone aggregate for wearing course including loading of aggregate with FE loader and hot mixing of stone aggregate, filler and bitumen in hot mix plant, transporting the mixed material by tipper to paver and laying the mixed materialwith paver finisher fitted with electronic sensing deviceto the required level and grade androlling by road roller as per MORTH specifications, to achieve the desired density, but excluding the cost of primer / tack coat.
1249@ 5.2% bitumen
1250OUTER DEVELOPMENT WORKS:
1251Fencing with 2" Ms pipe placed at 8 feet c/c 2.0 M high from GL welded together with 3/4" square hollow horizontal pipe and finished with pvc coated chain link 12 G -1.5" x 1.5" square tied up with binding wire incl excavation and foundation for MS pipe upto 750 mm deep embedded in PCC 1:3:6 (450X450X450) all complete
1252Providing and laying 80mm thick faciory made interlocking cement concrete blocks
1253SYNTHETIC WORKS:
1254Supply & installation of Silica PU synthetic (List approved Makes -Kdf,Polytan,Stockmeier)
1255Equipment & accesorries:
1256HS-510 Air Space Walker Double Specification- 1.Main frame 114mm. B class(3mm to 3.5mm. thickness) 2. Swinging paddle pipe 50mm. B class(3mm to 3.5mm. thickness) 3. Handle Pipe 30mm. B class(3mm to 3.5mm. thickness) 4. Permanent lubricated sealed bearing of reputed brand. 5. Nuts & Bolts Galvanized. 6. Nylon covers for covering the nuts & bolts. (List of approved makes-Trenz,Garden gym,Bajaj)
1257HS-511 Pull Chair Double Specification- 1. Center main pipe114mm. B class(3mm to 3.5mm. thickness) 2. Sitting pipe 40mm. B class(3mm to 3.5mm. thickness) 3. Both side vertical structure pipe 40mm. 4. Seat metallic sheet 3mm to 3.5mm. M.S 5. Seat moving pipe 2’’x2’’ square M.S 6. Upper handle pipe 40mm. 7. Grip handle 25 mm. 8. Permanent lubricated sealed bearing of reputed brand. 9. Nuts & Bolts Galvanized. 10. Nylon covers for covering the nuts & bolts. (List of approved makes-Trenz,Garden gym,Bajaj)
1258HS-513 Leg Press Specification- 1. Center main pipe114mm. B class (3mm to 3.5mm. thickness) 2. Sitting pipe 40mm.B class(3mm to 3.5mm. thickness) 3. Both side vertical structure pipe 40mm. 4.Seat metallic sheet 3mm to 3.5mm. M.S 5. Footrest M.S Checked plate 4mm. thickness 6. Permanent lubricated sealed bearing of reputed brand. 7. Nuts & Bolts Galvanized. 8. Nylon covers for covering the nuts & bolts. (List of approved makes-Trenz,Garden gym,Bajaj)
1259HS-514 Chest Press Specification- 1. Center main pipe114mm. B class(3mm to 3.5mm. thickness) 2. 2. Sitting pipe 40mm. B class(3mm to 3.5mm. thickness) 3. Both side vertical structure pipe 40mm. 4. Seat metallic sheet 3mm to 3.5mm. M.S 5. Seat moving pipe 2’’x2’’ square M.S 6. Upper handle pipe 40mm. 7. Grip handle 25 mm. 8. Permanent lubricated sealed bearing of reputed brand. 9. Nuts & Bolts Galvanized. 10. Nylon covers for covering the nuts & bolts. (List of approved makes-Trenz,Garden gym,Bajaj)
1260HS-519 Triple Twister Specification- 1. Center Standing pipe114mm. B class(3mm to 3.5mm. thickness) 2.Bottom twisting legs 32mm. B class(3mm to 3.5mm. thickness) or Iron channel 50mmX100mmX5mm 3. Twister plate 300mm. round 4. Handle Pipe 40mm. B class(3mm to 3.5mm. thickness) 5. Grip handle 25 mm. 6. Permanent lubricated sealed bearing of reputed brand. 7. Nuts & Bolts Galvanized. 8. Nylon covers for covering the nuts & bolts. (List of approved makes-Trenz,Garden gym,Bajaj)
1261HS-522 Bicycle Specification- 1.Main frame 114mm. B class(3mm to 3.5mm. thickness) 2.Upper frame 50mm. B class(3mm to 3.5mm. thickness) 3. Horizontal support 40mm. B class(3mm to 3.5mm. thickness) 4. Handle Pipe 30mm. B class(3mm to 3.5mm. thickness) 5. wheels Havey duly M.S plate 6. Revolving paddles. 7. Permanent lubricated sealed bearing of reputed brand. 8. Nuts & Bolts Galvanized. 9. Nylon covers for covering the nuts & bolts. (List of approved makes-Trenz,Garden gym,Bajaj)
1262HS-524 Arm Wheel Specification- 1.Central Standing Pipe 114mm. B class (3mm to 3.5mm. thickness) 2. Both side arm support 40mm. B class (3mm to 3.5mm. thickness) 3.Both side rotating wheels 30mm. B class (3mm to 3.5mm. thickness) 4. Both side central wheel supporting pipe 25 mm. B class(3mm to 3.5mm. thickness) 5. Permanent lubricated sealed bearing of reputed brand. 6. Nuts & Bolts Galvanized. 7. Nylon covers for covering the nuts & bolts. (List of approved makes-Trenz,Garden gym,Bajaj)
1263Parallel Bar Specification- 1.Central Standing Pipe 114mm. B class (3mm to 3.5mm. thickness) 2. Parallel handle pipe 32mm. B class (3mm to 3.5mm. thickness) 3. Nuts & Bolts Galvanized. 4. Nylon covers for covering the nuts & bolts. (List of approved makes-Trenz,Garden gym,Bajaj)
1264HS-536 Scaling Ladder Specification- 1.SidePipe 114mm. B class (3mm to 3.5mm. thickness) 2. Bars 30mm. B class (3mm to 3.5mm. thickness) (List of approved makes-Trenz,Garden gym,Bajaj)
1265TOTAL Open GYM
1266Badminton Court
1267EARTH WORKS:
1268Clearing grass, removal of rubbish up tp a distance of 50m outside the periphery of area
1269Excavation for roadway in earth, soil of all sorts, sand gravel, or soft murum including dressing section to the required grade, camber and isde slopes and conveying the excavated materials with all lifts upto a lead of 50m and spreading for embackment or stacking as directed.
1270Supply and stacking of good earth
1271DRAINAGE & TOE WALL WORKS
1272Providing and laying in position cement concrete M10 grade
1273Providing and laying in position cement concrete M15 grade
1274First class Brick work cement mortor 1:6
127512 mm cement plaster of mix :
1276providing and fixing of precast Rcc perforated drain cover of size 600 mm x600mm x75mm . With M30 Grade concrete and reinforcement 8 mm steel @ 100mm c/c. For easy flow of water.
1277ROAD WORKS:
1278Consolidation of subgrade with power road roller of 8 to 12 tonne capacity to required slopeincludingmaking goodtheundulations etc. with earth or quarry spoils etc.and rerolling the subgrade.
1279Construction of stabilised soil base with organo silance by providing lpcally available morum/soil 70% mixed with 30% granular sub-base
1280With material conforming to Grade-II (size range 53 mm to 0.075 mm ) having CBR Value-25
1281Providing, laying, spreading and compacting graded stone aggregate (size range 53 mm to 0.075 mm ) to wet mix macadam (WMM) specification including premixing the material with water at OMC in mechanical mix plant, carriage of mixed material by tipper to site,for all leads & lifts, laying in uniform layers with mechanical paver finisher in sub- base / base course on well prepared surface and compacting with vibratory roller of 8 to 10 tonne capacity to achieve the desired density, complete as per specifications and directions of Engineer-in-Charge.
1282Providing and applying primer coat
1283Providing and applying tack coat
1284Providing and laying Dense Bituminous macadam on prepared surface with specified graded crushed stone aggregate for profile corrective base/binder course including loading of aggregate with FE loader and hot mixing of stone aggregates and bitumen in hot mix plant, transporting the mixed material by tipper to paver and laying the mixed materialwith paver finisher fitted with electronic sensing deviceto the required level and grade androlling by road roller as per MORTH specifications, to achieve the desired density and compaction, but excluding the cost of primer /tack coat.
12854.5% bitumen
1286Providing and laying bituminous concreteon theprepared surface with specified graded crushed stone aggregate for wearing course including loading of aggregate with FE loader and hot mixing of stone aggregate, filler and bitumen in hot mix plant, transporting the mixed material by tipper to paver and laying the mixed materialwith paver finisher fitted with electronic sensing deviceto the required level and grade androlling by road roller as per MORTH specifications, to achieve the desired density, but excluding the cost of primer / tack coat.
1287@ 5.2% bitumen
1288OUTER DEVELOPMENT WORKS:
1289Fencing with 2" Ms pipe placed at 8 feet c/c 2.0 M high from GL welded together with 3/4" square hollow horizontal pipe and finished with pvc coated chain link 12 G -1.5" x 1.5" square tied up with binding wire incl excavation and foundation for MS pipe upto 750 mm deep embedded in PCC 1:3:6 (450X450X450) all complete
1290Providing and laying 80mm thick faciory made interlocking cement concrete blocks
1291SYNTHETIC WORKS:
1292Supply & installation of ( 8+2)mm synthetic Conipur HG eco system sports flooring approved by International basketball/hand ball / badmintion /federation List of approved Makes-(Conipur HG+, Polytan, Stockmeier)
1293Supply and installation of one layer of conipur 70 primer over concrete /bitumensurface at the rate of 0.15kg/sqm
1294Supply and installation of 8mm thick shockpad layer with SBR granules mixed with conipur 326 binder at the rate of 6 kg per sqm
1295Supply and installation of one layer sealing coat with conipur 220 at the rate of 750gm/sqm over the SBR
1296Supply and installation of 2-3mm thick conipur 227 PU
1297Supply and installation of top coat color PU paint as per approved shade.
1298Line marking as per international norms
1299Equipment & accesorries:
1300Supply & installation ofbadminton net and poles as approved .
1301TOTAL Badminton Court
1302Volleyball Court
1303EARTH WORKS:
1304Clearing grass, removal of rubbish up tp a distance of 50m outside the periphery of area
1305Excavation for roadway in earth, soil of all sorts, sand gravel, or soft murum including dressing section to the required grade, camber and isde slopes and conveying the excavated materials with all lifts upto a lead of 50m and spreading for embackment or stacking as directed.
1306Supply and stacking of good earth
1307DRAINAGE & TOE WALL WORKS
1308Providing and laying in position cement concrete M10 grade
1309Providing and laying in position cement concrete M15 grade
1310First class Brick work cement mortor 1:6
131112 mm cement plaster of mix :
1312providing and fixing of precast Rcc perforated drain cover of size 600 mm x600mm x75mm . With M30 Grade concrete and reinforcement 8 mm steel @ 100mm c/c. For easy flow of water.
1313ROAD WORKS:
1314Consolidation of subgrade with power road roller of 8 to 12 tonne capacity to required slopeincludingmaking goodtheundulations etc. with earth or quarry spoils etc.and rerolling the subgrade.
1315Construction of stabilised soil base with organo silance by providing lpcally available morum/soil 70% mixed with 30% granular sub-base
1316a) With material conforming to Grade-II (size range 53 mm to 0.075 mm ) having CBR Value-25
1317Providing, laying, spreading and compacting graded stone aggregate (size range 53 mm to 0.075 mm ) to wet mix macadam (WMM) specification including premixing the material with water at OMC in mechanical mix plant, carriage of mixed material by tipper to site,for all leads & lifts, laying in uniform layers with mechanical paver finisher in sub- base / base course on well prepared surface and compacting with vibratory roller of 8 to 10 tonne capacity to achieve the desired density, complete as per specifications and directions of Engineer-in-Charge.
1318Providing and applying primer coat
1319Providing and applying tack coat
1320Providing and laying Dense Bituminous macadam on prepared surface with specified graded crushed stone aggregate for profile corrective base/binder course including loading of aggregate with FE loader and hot mixing of stone aggregates and bitumen in hot mix plant, transporting the mixed material by tipper to paver and laying the mixed materialwith paver finisher fitted with electronic sensing deviceto the required level and grade androlling by road roller as per MORTH specifications, to achieve the desired density and compaction, but excluding the cost of primer /tack coat.
13214.5% bitumen
1322Providing and laying bituminous concreteon theprepared surface with specified graded crushed stone aggregate for wearing course including loading of aggregate with FE loader and hot mixing of stone aggregate, filler and bitumen in hot mix plant, transporting the mixed material by tipper to paver and laying the mixed materialwith paver finisher fitted with electronic sensing deviceto the required level and grade androlling by road roller as per MORTH specifications, to achieve the desired density, but excluding the cost of primer / tack coat.
1323@ 5.2% bitumen
1324Fencing with 2" Ms pipe placed at 8 feet c/c 2.0 M high from GL welded together with 3/4" square hollow horizontal pipe and finished with pvc coated chain link 12 G -1.5" x 1.5" square tied up with binding wire incl excavation and foundation for MS pipe upto 750 mm deep embedded in PCC 1:3:6 (450X450X450) all complete
1325Providing and laying 80mm thick faciory made interlocking cement concrete blocks
1326SYNTHETIC WORKS:
1327Supply & installation of ( 8+2)mm synthetic Conipur HG eco system sports flooring approved by International basketball/hand ball / badmintion /federation List of approved Makes-(Conipur MX+, Polytan, Stockmeier)
1328Supply and installation of one layer of conipur 70 primer over concrete /bitumensurface at the rate of 0.15kg/sqm
1329Supply and installation of 8mm thick shockpad layer with SBR granules mixed with conipur 326 binder at the rate of 6 kg per sqm
1330Supply and installation of one layer sealing coat with conipur 220 at the rate of 750gm/sqm over the SBR
1331Supply and installation of 2-3mm thick conipur 227 PU
1332Supply and installation of top coat color PU paint as per approved shade.
1333Line marking as per international norms
1334Equipment & accesorries:
1335Supply & installation ofvollyball net and poles as approved .
1336TOTAL Volleyball Court
1337Children Park
1338EARTH WORKS:
1339Clearing grass, removal of rubbish up tp a distance of 50m outside the periphery of area
1340Excavation for roadway in earth, soil of all sorts, sand gravel, or soft murum including dressing section to the required grade, camber and isde slopes and conveying the excavated materials with all lifts upto a lead of 50m and spreading for embackment or stacking as directed.
1341Supply and stacking of good earth
1342DRAINAGE & TOE WALL WORKS
1343Providing and laying in position cement concrete M10 grade
1344Providing and laying in position cement concrete M15 grade
1345First class Brick work cement mortor 1:6
134612 mm cement plaster of mix :
1347providing and fixing of precast Rcc perforated drain cover of size 600 mm x600mm x75mm . With M30 Grade concrete and reinforcement 8 mm steel @ 100mm c/c. For easy flow of water.
1348ROAD WORKS:
1349Consolidation of subgrade with power road roller of 8 to 12 tonne capacity to required slopeincludingmaking goodtheundulations etc. with earth or quarry spoils etc.and rerolling the subgrade.
1350Construction of stabilised soil base with organo silance by providing lpcally available morum/soil 70% mixed with 30% granular sub-base
1351With material conforming to Grade-II (size range 53 mm to 0.075 mm ) having CBR Value-25
1352Providing, laying, spreading and compacting graded stone aggregate (size range 53 mm to 0.075 mm ) to wet mix macadam (WMM) specification including premixing the material with water at OMC in mechanical mix plant, carriage of mixed material by tipper to site,for all leads & lifts, laying in uniform layers with mechanical paver finisher in sub- base / base course on well prepared surface and compacting with vibratory roller of 8 to 10 tonne capacity to achieve the desired density, complete as per specifications and directions of Engineer-in-Charge.
1353Providing and applying primer coat
1354Providing and applying tack coat
1355Providing and laying Dense Bituminous macadam on prepared surface with specified graded crushed stone aggregate for profile corrective base/binder course including loading of aggregate with FE loader and hot mixing of stone aggregates and bitumen in hot mix plant, transporting the mixed material by tipper to paver and laying the mixed materialwith paver finisher fitted with electronic sensing deviceto the required level and grade androlling by road roller as per MORTH specifications, to achieve the desired density and compaction, but excluding the cost of primer /tack coat.
13564.5% bitumen
1357Providing and laying bituminous concreteon theprepared surface with specified graded crushed stone aggregate for wearing course including loading of aggregate with FE loader and hot mixing of stone aggregate, filler and bitumen in hot mix plant, transporting the mixed material by tipper to paver and laying the mixed materialwith paver finisher fitted with electronic sensing deviceto the required level and grade androlling by road roller as per MORTH specifications, to achieve the desired density, but excluding the cost of primer / tack coat.
1358@ 5.2% bitumen
1359Fencing with 2" Ms pipe placed at 8 feet c/c 2.0 M high from GL welded together with 3/4" square hollow horizontal pipe and finished with pvc coated chain link 12 G -1.5" x 1.5" square tied up with binding wire incl excavation and foundation for MS pipe upto 750 mm deep embedded in PCC 1:3:6 (450X450X450) all complete
1360Providing and laying 80mm thick faciory made interlocking cement concrete blocks
1361SYNTHETIC WORKS:
1362Supply & installation of Silica PU synthetic List of approved Makes-(KDF,Polytan, Stockmeier)
1363Equipment & accesorries:
1364Equipment & accesorries:
1365TOTAL CHILDREN PARK
1366Renovation Tennis Court
1367EARTH WORKS:
1368Repair of existing surface
1369Fencing with 2" Ms pipe placed at 8 feet c/c 2.0 M high from GL welded together with 3/4" square hollow horizontal pipe and finished with pvc coated chain link 12 G -1.5" x 1.5" square tied up with binding wire incl excavation and foundation for MS pipe upto 750 mm deep embedded in PCC 1:3:6 (450X450X450) all complete
1370Providing and laying 80mm thick faciory made interlocking cement concrete blocks
1371SYNTHETIC WORKS:
1372Supply & installation of ( 8+2)mm synthetic Conipur HG eco system sports flooring approved by International basketball/hand ball / badmintion /federation List of approved Makes-(ConipurHG, Polytan, Stockmeier)
1373Supply and installation of one layer of conipur 70 primer over concrete /bitumensurface at the rate of 0.15kg/sqm
1374Supply and installation of 8mm thick shockpad layer with SBR granules mixed with conipur 326 binder at the rate of 6 kg per sqm
1375Supply and installation of one layer sealing coat with conipur 220 at the rate of 750gm/sqm over the SBR
1376Supply and installation of 2-3mm thick conipur 227 PU
1377Supply and installation of top coat color PU paint as per approved shade.
1378Line marking as per international norms
1379Equipment & accesorries:
1380Supply & installation oftennis net and polesas approved .
1381TOTAL RENOVATION TENNIS COURT
1382EXISTING BADMINTON COURT SEATING ARRANGEMENT
1383Providing and fabricating structural steel work in rolled sections like joists, channels, angles, tees etc. as per detailed design and drawings or as directed including cutting, fabricating, hoisting, erecting, fixing in position making riveted / bolted /welded connections without connecting plates, braces etc. and including one coat of anticorrosive paint and over it two coats of oil painting of approved quality and shade etc. complete.
1384Providing and fixing Indian teak wood planking 25mm thick for flooring plained on both sides, tongued and grooved including scaffolding, if necessary, and one coat of primer etc. complete.
1385Providing and applying external raincoat painting with crack filling acrylic polymer based chemical compound coating to the external surface of wal stoprevent water seepage in the masonry walls during monsoon added with required shade Steiner to give required shade to the surface in two coats. Including providing three coat of priming of polymer base primer including preparing surface scrapping the existing loose old paint, removing loose particles of sand on the surface opening and cleaning the cracks developed in the external plaster, removing loose particles by chiseling, filling cracks by chemicals compound of approved make with proper penetration etc. Coating of Raincoat with the help of brush and as per instructions and specification given by manufacturer and with instruction from Engineer in-charge. Work shall be executed by certified applicator only and covering gurantee of 3 years on court stamp paper of Rs.500/-and necessary testing etc. complete.
1386TOTAL EXISTING BADMINTON COURT SEATING ARRANGEMENT
1387ELECTRICAL WORKS FOR CHILDREN PARK
1388SUBHEAD- I:-EXTERNAL LIGHTING
1389Supplying, erecting & terminating XLPE armoured cable 2 core 6 sq. mm. aluminium conductor with continuous 5.48 sq. mm. (12 SWG) G.I. earth wire complete erected with glands & lugs, on wall/ trusses/pole or laid in provided trench/ pipe as per specification no.CB-LT/AL
1390Supplying, erecting & terminating XLPE armoured cable 2 core 10 sq. mm. aluminium conductor with continuous 5.48 sq. mm. (12 SWG) G.I. earth wire complete erected with glands & lugs, on wall/ trusses/pole or laid in provided trench/ pipe as per specification no. CB-LT/AL
1391Supplying, erecting & terminating XLPE armoured cable 4 core 6 sq. mm. aluminium conductor with continuous 5.48 sq. mm. (12 SWG) G.I. earth wire complete erected with glands & lugs, on wall/ trusses/pole or laid in provided trench/ pipe as per specification no. CB-LT/AL
1392Supplying, erecting & terminating XPLE armoured cable 4 core 16 sq. mm. aluminium conductor with continuous 5.48 sq. mm. (12 SWG) G.I. earth wire complete erected with glands & lugs, on wall/ trusses/pole or laid in provided trench/ pipe as per specification no. CB-LT/AL
1393Providing & erecting epoxy outdoor / indoor end termination kit for LT XLPE armoured cable 2.5 to 16 sq. mm. cable, with necessary material as per specification no. CB-JT/LT
1394Supplying & erecting mains with 3x2.5 Sq.mm F.R copper PVC insulated wire laid in providedonduit/trunking/inside pole/Bus bars or any other places as per specification No: WGMA/ BW
1395Supplying and laying (including excavation of suitable width & depth up to 90 cm) 200 mm outside dia, double wall corrugated pipes (DWC) of HDPE for enclosing cable below ground/road surface, to required depth complete.
1396Supplying and erecting steel tubular swaged pole 139.7 x 114.3 x 88.9 mm. dia with 4.5x3.65x3.25 mm thickness (4.5 + 1.75 + 1.75 m) length respectively and total 8 m long with pole cap, base plate in provided foundation.(weight 101 kg.) as per specification no. OH-PL/STP
1397High Mast
1398Supplying and erecting LED Flood light fitting of 120W, including lamp, with PF > 0.95,class IP 65 and above Housing of pressure die cast aluminium alloy and heat sink extruded aluminium complete per specification No FG-ODF/FLS-2
1399F.P.(External Lighting)
1400Design, manufacture,Supply, Installation, testing and commissioning at works ofDouble door panel fabricated with minimum 2mm thick CRCA sheet, Conform to IS Specification, with IP-55 enclosure protection, as per IS-2137(Revised), floor mounting free standing on a suitable massanory pedestal outdoor type panel,provided with hinged detachable and lockable outer opening doors with the following incoming/outgong MCCB/ MCBs mounted therein including making connections/ interconnections, earthing, painting etc. as required.The panel shall have canopy arrangement on the top.All MCB to be C curve .
1401Feeder Pillar
1402Incoming
1403The incoming shall comprise the following :-
14041 No 63 A FP MCB,
1405Metering for incoming:
1406Digital Multifunction meter (MFM-4) with RS-485 communication port for measurement ofPF, V, A & Hz , equivalent to EM6459, with CT as required.
1407Phase indicating lamps RYBwith 2 Amps SP MCB back up.
1408Bus Bars
140980 Amps TPN Aluminium Bus Bars of suitable length Bus bars shall be colour coded and insulated by heat shrinkable sleaves & clip on shrouds for joints. The current density of Bus bar shall be 1.2 sq.mm./amp.
1410Outgoing (All MCB shall be suitable for motor duty& with heavy duty detachable solid neutral link ):
14119 nos 25A DP MCB 10 KA breaking capacity controlled by and including providing 63 DP MCB, 63 A DP contactor and Timer.
1412Feeder Pillardescribed as above and all as per specification.
1413Earthing
1414Providing earthing with galvanized iron earth plate size 60 x 60 x 0.6 cm complete with all materials, testing & recording the results as per specification no. EA-EP
1415Supplying and erecting aluminium strip of required sizes used for earthing on wall and/or any other purpose with necessary aluminium clamps fixed on wall painted with bituminous paint in an approved manner with joints required. As per specification no EAEP.
1416Supplying and erecting GI earth wire of high purity of different sizes used for earthing or any other purposes on wall with necessary G. I. Clamps fixed on wall/cable/ conduit with screws in an approvedmanner.
1417Providing pipe type earthing with 40mm. dia. G.l. pipe or 20 mm dia. G.l. Rod complete with all materials as per specification no. EAEP
1418TOTAL ELECTRICAL WORKS FOR CHILDREN PARK
1419ELECTRICAL WORKS FOROPEN GYM AND TENNIS
1420SUBHEAD- I:-EXTERNAL LIGHTING
1421Supplying, erecting & terminating XLPE armoured cable 2 core 6 sq. mm. aluminium conductor with continuous 5.48 sq. mm. (12 SWG) G.I. earth wire complete erected with glands & lugs, on wall/ trusses/pole or laid in provided trench/ pipe as per specification no.CB-LT/AL
1422Supplying, erecting & terminating XLPE armoured cable 2 core 10 sq. mm. aluminium conductor with continuous 5.48 sq. mm. (12 SWG) G.I. earth wire complete erected with glands & lugs, on wall/ trusses/pole or laid in provided trench/ pipe as per specification no. CB-LT/AL
1423Supplying, erecting & terminating XLPE armoured cable 4 core 6 sq. mm. aluminium conductor with continuous 5.48 sq. mm. (12 SWG) G.I. earth wire complete erected with glands & lugs, on wall/ trusses/pole or laid in provided trench/ pipe as per specification no. CB-LT/AL
1424Supplying, erecting & terminating XPLE armoured cable 4 core 16 sq. mm. aluminium conductor with continuous 5.48 sq. mm. (12 SWG) G.I. earth wire complete erected with glands & lugs, on wall/ trusses/pole or laid in provided trench/ pipe as per specification no. CB-LT/AL
1425Providing & erecting epoxy outdoor / indoor end termination kit for LT XLPE armoured cable 2.5 to 16 sq. mm. cable, with necessary material as per specification no. CB-JT/LT
1426Supplying & erecting mains with 3x2.5 Sq.mm F.R copper PVC insulated wire laid in providedonduit/trunking/inside pole/Bus bars or any other places as per specification No: WGMA/ BW
1427Supplying and laying (including excavation of suitable width & depth up to 90 cm) 200 mm outside dia, double wall corrugated pipes (DWC) of HDPE for enclosing cable below ground/road surface, to required depth complete.
1428Supplying and erecting steel tubular swaged pole 139.7 x 114.3 x 88.9 mm. dia with 4.5x3.65x3.25 mm thickness (4.5 + 1.75 + 1.75 m) length respectively and total 8 m long with pole cap, base plate in provided foundation.(weight 101 kg.) as per specification no. OH-PL/STP
1429High Mast
1430Supplying and erecting 12.5 m (clear height) High Mast (Top- 150mm, Bottom- 360mm) with lowering and raising motorized unit, lantern carriage assembly suitable for max. 6 nos. luminaries and its control gear box, lightning finial arrangement for fixing aviation light and foundation bolts on provided foundation as per specification no.OH-PL/HM (excluding luminaries ).
1431Supplying and erecting LED Flood light fitting of 120W, including lamp, with PF > 0.95,class IP 65 and above Housing of pressure die cast aluminium alloy and heat sink extruded aluminium complete per specification No FG-ODF/FLS-2
1432F.P.(External Lighting)
1433Design, manufacture,Supply, Installation, testing and commissioning at works ofDouble door panel fabricated with minimum 2mm thick CRCA sheet, Conform to IS Specification, with IP-55 enclosure protection, as per IS-2137(Revised), floor mounting free standing on a suitable massanory pedestal outdoor type panel,provided with hinged detachable and lockable outer opening doors with the following incoming/outgong MCCB/ MCBs mounted therein including making connections/ interconnections, earthing, painting etc. as required.The panel shall have canopy arrangement on the top.All MCB to be C curve .
1434Feeder Pillar
1435Incoming
1436The incoming shall comprise the following :-
14371 No 63 A FP MCB,
1438Metering for incoming:
1439Digital Multifunction meter (MFM-4) with RS-485 communication port for measurement ofPF, V, A & Hz , equivalent to EM6459, with CT as required.
1440Phase indicating lamps RYBwith 2 Amps SP MCB back up.
1441Bus Bars
144280 Amps TPN Aluminium Bus Bars of suitable length Bus bars shall be colour coded and insulated by heat shrinkable sleaves & clip on shrouds for joints. The current density of Bus bar shall be 1.2 sq.mm./amp.
1443Outgoing (All MCB shall be suitable for motor duty& with heavy duty detachable solid neutral link ):
14449 nos 25A DP MCB 10 KA breaking capacity controlled by and including providing 63 DP MCB, 63 A DP contactor and Timer.
1445Feeder Pillardescribed as above and all as per specification.
1446Earthing
1447Providing earthing with galvanized iron earth plate size 60 x 60 x 0.6 cm complete with all materials, testing & recording the results as per specification no. EA-EP
1448Supplying and erecting aluminium strip of required sizes used for earthing on wall and/or any other purpose with necessary aluminium clamps fixed on wall painted with bituminous paint in an approved manner with joints required. As per specification no EAEP.
1449Supplying and erecting GI earth wire of high purity of different sizes used for earthing or any other purposes on wall with necessary G. I. Clamps fixed on wall/cable/ conduit with screws in an approvedmanner.
1450Providing pipe type earthing with 40mm. dia. G.l. pipe or 20 mm dia. G.l. Rod complete with all materials as per specification no. EAEP
1451TOTALELECTRICAL WORKS FOROPEN GYM AND TENNIS
1452ELECTRICAL WORKS FOR BADMINTON & VOLLEYBALL COURT
1453SUBHEAD- I:-EXTERNAL LIGHTING
1454Supplying, erecting & terminating XLPE armoured cable 2 core 6 sq. mm. aluminium conductor with continuous 5.48 sq. mm. (12 SWG) G.I. earth wire complete erected with glands & lugs, on wall/ trusses/pole or laid in provided trench/ pipe as per specification no.CB-LT/AL
1455Supplying, erecting & terminating XLPE armoured cable 2 core 10 sq. mm. aluminium conductor with continuous 5.48 sq. mm. (12 SWG) G.I. earth wire complete erected with glands & lugs, on wall/ trusses/pole or laid in provided trench/ pipe as per specification no. CB-LT/AL
1456Supplying, erecting & terminating XLPE armoured cable 4 core 6 sq. mm. aluminium conductor with continuous 5.48 sq. mm. (12 SWG) G.I. earth wire complete erected with glands & lugs, on wall/ trusses/pole or laid in provided trench/ pipe as per specification no. CB-LT/AL
1457Supplying, erecting & terminating XPLE armoured cable 4 core 16 sq. mm. aluminium conductor with continuous 5.48 sq. mm. (12 SWG) G.I. earth wire complete erected with glands & lugs, on wall/ trusses/pole or laid in provided trench/ pipe as per specification no. CB-LT/AL
1458Providing & erecting epoxy outdoor / indoor end termination kit for LT XLPE armoured cable 2.5 to 16 sq. mm. cable, with necessary material as per specification no. CB-JT/LT
1459Supplying & erecting mains with 3x2.5 Sq.mm F.R copper PVC insulated wire laid in providedonduit/trunking/inside pole/Bus bars or any other places as per specification No: WGMA/ BW
1460Supplying and laying (including excavation of suitable width & depth up to 90 cm) 200 mm outside dia, double wall corrugated pipes (DWC) of HDPE for enclosing cable below ground/road surface, to required depth complete.
1461Supplying and erecting steel tubular swaged pole 139.7 x 114.3 x 88.9 mm. dia with 4.5x3.65x3.25 mm thickness (4.5 + 1.75 + 1.75 m) length respectively and total 8 m long with pole cap, base plate in provided foundation.(weight 101 kg.) as per specification no. OH-PL/STP
1462High Mast
1463Supplying and erecting 12.5 m (clear height) High Mast (Top- 150mm, Bottom- 360mm) with lowering and raising motorized unit, lantern carriage assembly suitable for max. 6 nos. luminaries and its control gear box, lightning finial arrangement for fixing aviation light and foundation bolts on provided foundation as per specification no.OH-PL/HM (excluding luminaries ).
1464Supplying and erecting LED Flood light fitting of 120W, including lamp, with PF > 0.95,class IP 65 and above Housing of pressure die cast aluminium alloy and heat sink extruded aluminium complete per specification No FG-ODF/FLS-2
1465F.P.(External Lighting)
1466Design, manufacture,Supply, Installation, testing and commissioning at works ofDouble door panel fabricated with minimum 2mm thick CRCA sheet, Conform to IS Specification, with IP-55 enclosure protection, as per IS-2137(Revised), floor mounting free standing on a suitable massanory pedestal outdoor type panel,provided with hinged detachable and lockable outer opening doors with the following incoming/outgong MCCB/ MCBs mounted therein including making connections/ interconnections, earthing, painting etc. as required.The panel shall have canopy arrangement on the top.All MCB to be C curve .
1467Feeder Pillar - X
1468Incoming
1469The incoming shall comprise the following :-
14701 No 63 A FP MCB,
1471Metering for incoming:
1472Digital Multifunction meter (MFM-4) with RS-485 communication port for measurement ofPF, V, A & Hz , equivalent to EM6459, with CT as required.
1473Phase indicating lamps RYBwith 2 Amps SP MCB back up.
1474Bus Bars
147580 Amps TPN Aluminium Bus Bars of suitable length Bus bars shall be colour coded and insulated by heat shrinkable sleaves & clip on shrouds for joints. The current density of Bus bar shall be 1.2 sq.mm./amp.
1476Outgoing (All MCB shall be suitable for motor duty& with heavy duty detachable solid neutral link ):
14779 nos 25A DP MCB 10 KA breaking capacity controlled by and including providing 63 DP MCB, 63 A DP contactor and Timer.
1478Feeder Pillardescribed as above and all as per specification.
1479Earthing
1480Providing earthing with galvanized iron earth plate size 60 x 60 x 0.6 cm complete with all materials, testing & recording the results as per specification no. EA-EP
1481Supplying and erecting aluminium strip of required sizes used for earthing on wall and/or any other purpose with necessary aluminium clamps fixed on wall painted with bituminous paint in an approved manner with joints required. As per specification no EAEP.
1482Supplying and erecting GI earth wire of high purity of different sizes used for earthing or any other purposes on wall with necessary G. I. Clamps fixed on wall/cable/ conduit with screws in an approvedmanner.
1483Providing pipe type earthing with 40mm. dia. G.l. pipe or 20 mm dia. G.l. Rod complete with all materials as per specification no. EAEP
1484TOTAL ELECTRICAL WORKS FOR BADMINTON & VOLLEYBALL COURT
1485PART-D TOTAL SPORTS WORK
1486SUMMARY
1487Total Part A + Part B + Part C + Part D
Disclaimer :