Tender For Repairing Of Pre-Fabricated Bsl Iii Laboratory With 2Yrs Of Cmc And The Cmc May Be Extended Up To 5Yrs (On Yearly Basis), kolkata-West Bengal

Animal Resources Development Department has published Tender For Repairing Of Pre-Fabricated Bsl Iii Laboratory With 2Yrs Of Cmc And The Cmc May Be Extended Up To 5Yrs (On Yearly Basis). Submission Date for this Tender is 11-08-2023. Autoclave and Sterilizer Equipment Tenders in kolkata West Bengal. Bidders can get complete Tender details and download the document.




Tender Notice

38763767
Tender For Repairing Of Pre-Fabricated Bsl Iii Laboratory With 2Yrs Of Cmc And The Cmc May Be Extended Up To 5Yrs (On Yearly Basis)
Open Tender
Indian
West Bengal
Kolkata
11-08-2023

Tender Details

Repairing Of Pre-Fabricated Bsl Iii Laboratory With 2Yrs Of Cmc And The Cmc May Be Extended Up To 5Yrs ( On Yearly Basis ) , The Repair Of Pre-Fabricated Bsl-Iii Lab , Installation Of New Plc / Bms Control For Bsl 3 Lab Operation & Monitoring , Supply& Installation Ofahu With Pre & Fine Filters , Exhaust Ahu Motor Repair , Supply & Installation Of Supply Terminal Gel Seal Mini Pleat Hepa Filters H13 – 5 No , Supply & Installation Of Exhaust Terminal Gel Seal Mini Pleat Hepa Filters H13–04No , Service & Maintenance Of Double Door Autoclave , Replacement Of Air Cooled Chiller With 11 Tr Condensing Unit. , Replacement Of Ahu Water Pipes With Condensing Unit Coil , Repair Of Cassette Ac 2 Ton01 No , Repair Of 1.5 Ton Split Ac – 03 No , Repair Of Biosafety Cabinet B2 Type -01 No , Replacement / Repair Of 20 Kva Ups , Supply & Installation Of 20 Kva Ups Batteries , Supply & Installation Of Temp / Rh / Dp Monitor With Alarm For The Facility – 02 N0 , Supply & Installation Of Differential Pressure Gauges – 06 No , Smoke Detectors And Alarm System: , Replacement Of Faulty Ceiling Lights , Repair Of Static Pass Box – 02 No , Repair And Replacement Of Cctv Cameras- 04Camera, Dvr And Monitor , Service / Maintenance Of Dg Set , Repair & Maintenance Of Decontamination System , Repair Of Refrigerator , Repair Of -86 Deep Freezer , Air Balancing For Maintaining Negative Pressure Gradient Inside The Facility. , Execution Of Cmc , 1St Year Cmc , 2Nd Year Cmc , 3Rd Year Cmc , 4Th Year Cmc , 5Th Year Cmc

Key Value

Document Fees
Refer document
EMD
INR 255000.0 /-
Tender Value
Refer document