| 1 | Supply and laying in replacement of Cross linked poly-ethylene (XLPE) insulated, screened, PVC bedded, galvanised steel strip or wire armoured, electric power cables ( heavy duty) with stranded aluminium conductor, 1100 voltsLT grade of cross-sectionalarea 10 Sqmm 02 core laid in trenches/through pipein road crossings/ paths /drains /ducts /floors /along poles/walls/ceilings/ equipments etcsupplied, fixed/ laid in repair including commissioning and testingcomplete all as specified and as directed by Engineer-in-Charge.(Note: :-(i) Necessary excavation and earth work, brick protection, sand cushioning and cover and GI pipe shall be measured and paid for separately.(ii) Road manually cutting/floor cutting/cutting holes etc in wall required for laying /fixing of cable etc shall be made good as per existing site condition. Nothing extra shall be admissibleon this accountand quoted rate for this item shall bedeemed to include for the same) Note for Item No 1 to 71 Make :- Havells/KEI/POLYCAB2. LT fault / reapir and maintanace intimated to the contractor or his rep at any time day or night, through complaint slip or telephonically must be rectified by the contractor within 8 Hrs. If contractor fails to rectify the fault with in 8 Hrs a panelty of Rs 500 per day per complaint will be deducted till the fault/complaint is rectified.3. All Material required for the repair and matainance work considered in the CA will be made available by the contractor with in 3 Hr. |
| 2 | Ditto All as per Srl item No 01 here in above but size of cable 16 Sqmm 4 core |
| 3 | Ditto All as per Srl item No 01 here in above but size of cable 25 Sqmm 2 core |
| 4 | Ditto All as per Srl item No 01 here in above but size of cable 25 Sqmm 4 core |
| 5 | Ditto All as per Srl item No 01 here in above but size of cable 35 Sqmm 3.5 core |
| 6 | Ditto All as per Srl item No 01 here in above but size of cable 50 Sqmm 3.5 core |
| 7 | Ditto All as per Srl item No 01 here in above but size of cable 95 Sqmm 3.5 core |
| 8 | Ditto All as per Srl item No 01 here in above but size of cable 120 Sqmm 3.5 core |
| 9 | Ditto All as per Srl item No 01 here in above but size of cable 150 Sqmm 3.5 core |
| 10 | Ditto All as per Srl item No 01 here in above but size of cable 185Sqmm 3.5 core |
| 11 | Dismantling Cross-Arms of Mild Steel Channel or Angle Sections, etc, including Mild Steel Bolts, Nuts, Washers, etc., complete all as specified and as directed. |
| 12 | Dismantling Insulators like Pin type, Shackle type from existing Electric Poles of any description and any size, seggregating Seviceable Insulators and keep in safe custody for re-use, complete all as specified and as directed. |
| 13 | Dismantling ACSR or AAC Conductors from the Disturbed Span including Line Spacer, etc., complete all as specified and as directed. |
| 14 | Dismantling Earth Wire, Cradle Guarding, etc., complete all as specified and as directed. |
| 15 | Cable jointing kitfor LV/LT 1100 V cable for straight through, heat shrinkable type joint kit complete with jointing material and accessories suitable for 25 Sqmm to 50 Sqmm 3.5 coreXLPE armoured aluminium conductor cable including testing after jointing, fixing in replacementcomplete all as specified as directed by Engineer-in-Charge. |
| 16 | Ditto All as per Srl item No 15 here in above but 70 Sqmm to 150 sqmm 3.5 Core |
| 17 | Ditto All as per Srl item No 15 here in above but 185 Sqmm to 300 sqmm 3.5 Core |
| 18 | Cable indoor / outdoor end terminals jointing kitfor LV/LT 1100 V cable heat shrinkable type joint kit complete with jointing material and accessories, thimbles etc suitable for 25 Sqmm to 50 Sqmm 3.5 coreXLPE armoured aluminium conductor cable including testing after jointing, fixing in replacementcomplete all as specified as directed by Engineer-in-Charge. |
| 19 | Ditto All as per Srl item No 18 here in above but 70 Sqmm to 150 sqmm 3.5 Core |
| 20 | Ditto All as per Srl item No 18 here in above but 185 Sqmm to 300 sqmm 3.5 Core |
| 21 | Taking out old LT underground cable and laying after removing of defects any type/size laid in trenches/through pipein road crossings/ paths /drains /ducts /floors /along poles/walls/ceilings/ equipments etc including commissioning and testingcomplete all as specified and as directed by Engineer-in-Charge. |
| 22 | Supply and laying un-reinforce precast concrete cable cover, class LV type-1 Flat , size 250 mmX150 mmx 40mm for protection of cablecomplete all as specified and as directed by Engineer-in-Charge. |
| 23 | Dismantling unserviceable LT Poles of any description and any size including demolition of Cement Concrete (as/if required) and made good disturbed Ground complete all as specified and as directed.Note : Unsv Poles will be dismantled at Ground Level and disturbed ground will made good as directed for which Earthwork, demolition of Cement Concrete, etc. will not be measured and paid separately. |
| 24 | Supply & Erecting Steel Tubular Swaged Pole Type 410-SP-31 (9.0 Metre long) including Cast Iron Base Plate, Finial Taper Plug, Cap, Mild Steel Bolts, Nuts, Screws including applying two coats of Black Bituminous Paint Internally and Externally from bottom End of Pole upto PCC Coping and applying with two coats of Aluminium Painting over a coat of red oxide Primer (Externally from Top of Coping)and applying Two Coats of Synthetic Enamel Painting in alternate Yellow & Black Strips Painting (4 No. Each Strip 300mm wide) andalso including numbering to poles with synthetic enamel paint on black base of size 15 cm x 10 cm and numbering in 8 cm height of number with white paint complete all as specified and as directed.Note : Earthwork, Cement Concrete, etc. will be measured and paid under approprite Items. |
| 25 | S&F Pre-stressed concrete poles 9 meter long, 102mm x 172mm at top and 102 mm x 279 mm at bottom, class 10, complying with requirements of IS-1678, including painting with two coats of synthetic enamel paint (in alternate black & white/yellow strips of 30 cm height) upto 1.5 meter height from top of PCC coping and also including numbering to poles with synthetic enamel paint on black base of size 15 cm x 10 cm and numbering in 8 cm height of number with white paint complete all as specified and as directed by the Engineer-in-Charge. |
| 26 | Supply and Fixing in replacement Stay assembly complete with 16 mm dia, 2000 mm long GI stay rod, with threaded ends and GI nuts, two number thimbles, MS galvanised clamps made out of 40mmx 6mm flat iron including MS nuts, bolts and washers, 300mm x 300mm x 6mm MS galvanised stay plate, stay bow, galvanized stay strand 7/4 mm including shackle and stay clamp and also including painting of exposed MS work with two coats of aluminium paint over a coat of red oxide zinc chromate primer, materialand labourcomplete all as shown in electrical plate No 1 of MES Schedule Part-I completeall as specified and as directed by Engineer-in-Charge.(Note: -(i) Excavation & earthwork, concrete pit, loop type insulators shall be measured & paid for separately under appropriate items of this Schedule .) |
| 27 | Plain cement concrete (1:3:6) type C-2 using 20mm graded stone aggregates as in foundation for stay and copping of pole above ground levelincludingfinishing to exposed concrete surfaces even and fair and provision of form work for rough finished surfaces complete all as specified and as directed by Engineer-in-Charge. |
| 28 | Plain cement concrete (1:4:8) type D-2 using 40mm graded stone aggregates as in foundation for pole complete all as specified and as directed by Engineer-in-Charge. |
| 29 | Demolition of old PCC foundation block/copping of LT/HT pole complete all as specified and as directed by Engineer-in-Charge. |
| 30 | Excavating in trenches, n exc 1.5 m wide and n exc 1.5 m in depth; for foundation, etc. or for shafts, wells, cesspits, manholes, pier holes, etc. nexc 10 sq m on plan and n exc 1.5 m in depth and getting out in soft/loose soil. complete all as specified and as directed by Engineer-in-Charge. |
| 31 | Excavating in trenches, n exc 1.5 m wide andexc 1.5 m in depth; for foundation, etc. or for shafts, wells, cesspits, manholes, pier holes, etc. nexc 10 sq m on plan andexc 1.5 m in depth but not exc 3 m in depth and getting out in soft/loose soilcomplete all as specified and as directed by Engineer-in-Charge. |
| 32 | Returning, filling in soft/loose soil including spreading, leveling, watering and well ramming, in layers not exc 25 cm complete all as specified and as directed by the Engineer-in-Charge. |
| 33 | Removingof surplus soil to a distance not exc. 50 meter and depositing where directed at a level not exc.1.5 metre above the starting point complete all as specified and as directed by the Engineer-in-Charge. |
| 34 | Removing building materials etc ( other than spoil payable underitem no 33 above) to a distance of n exc 3 Km or under , beyond the lead included in the rates , including, loading unloading and stacking at the destination.complete all as specified and directed by Engineer in Charge. |
| 35 | Local tibba dry sand cushioning and cover (8 cmthick layer of sand before laying of cable and 15 cm thick layer of sand after laying of cable)for protection of cable, material and labour complete all as specified and as directed by Engineer-in-Charge. |
| 36 | Supplyand fixing in replacement GI pipe light grade 40 mm bore (ISI marked) laid in trenches/ road crossings/ fixed to poles/ceiling / along walls/ path /drain/floors with and including all necessary clamps, nuts, bolts, washers etc and all fittings as required, complete all as specifiedand as directed by the Engineer-in-Charge.(Note :- Necessary excavation, earth work and same work shall be measured and paid for separately.) |
| 37 | Ditto All as per Srl item No 36 here in above but dia of pipe 50 mm |
| 38 | Ditto All as per Srl item No 36 here in above but dia of pipe 80 mm |
| 39 | Boring of holes under road 110 mm dia, pavement, hard standingby trench less technology(manually) with out disturbing the top surface of roadsfor laying of cables/GI pipescomplete all as specified and as directed by the Engineer-in-Charge. |
| 40 | Supply and fixingin replacementMCCB,63Amps, 4 pole, 415 Volts, rupturingcapacity not less than 25 KA Ics=100%Icu,fixed Thermal Megnetic Release including thimbles, nuts, bolts, washers etc. making including incoming and outgoing connectioncompleteall as specified. Make: ABB/L&T/havells Note :- contractor shall have to purchase all items from sl no. 39 to 43 on immediate acceptance of the contract and same shall be deposited to MES store and fixing of the same will be carried out based on complaint. |
| 41 | Ditto All as per Srl item No 40 here in above but 100 Amps |
| 42 | Ditto All as per Srl item No 40 here in above but 160 Amps |
| 43 | Ditto All as per Srl item No 40 here in above but 36 KA 200 Amps |
| 44 | Ditto All as per Srl item No 40 here in above but 36 KA 400 Amps |
| 45 | Supplying and laying heavy duty PVC cable insulated standard Aluminium conductor 1100 volt grade served with inner sheathing of PVC tape and overall PVC sheathed in service connection suspended by insulating hangers more than 1 mtr apart including 4mm suspension wire, one twin core cable flat or circular, size 06 sq mm in replacement complete all as specified and as directed by Engineer-in-Charge. |
| 46 | Ditto All as per Srl item No 45 here in above but 10 Sqmm |
| 47 | Ditto All as per Srl item No 45 here in above but 16 Sqmm |
| 48 | Supplying and stringing in replacement Aluminium conductor, steel reinforced (ACSR)any type of ACSR conductor as per site requirement of size /make as ordered including stringingfor overhead line on LT poles including aluminum binding wire 14 SWG, jumpers, line tapes, conducting jelly etc complete all as specified and as directed by Engineer-in-Charge.(Notes : (i) The ACSR conductors shall be conforming to IS-398 and as specified in SSR Part-I.(ii) The unit rate quoted shall also be deemed to include for supply & fixing of aluminium binding wire, aluminium tapes etc which shall not be included in the weight of conductors.(iii) Weight of conductors shall be determined by measuring true horizontal distance between centers of two adjacent poles and compoundingthe weight of conductors of that size and length and 3% extra added for sag, jointing, jumpers etc.(iv) Weight of the conductors shall be calculated from the nominal weights given in tables in the relevant IS.) |
| 49 | M & L preparing old painted surfaces by scraping and removing old paints, rust, etc. from Steel Tubular Poles (above the Planting Depth and PCC Copings) and Mild Steel Cross Arms, Cable Protection Pipe, Brackets, etc. and applying one Coat of Red Oxide Zinc Chrome Primer, alternate Yellow & Black Strips Painting (5 No. Each Strip 300 mm wide) and remaining portion of Pole also including numbering to poles with synthetic enamel paint on black base of size 15 cm x 10 cm and numbering in 8 cm height of number with white paint and Cross Arms, Cable Protection Pipe, Brackets, etc. treated with Two Coats of Aluminium Paintcomplete all as specified and as directed. |
| 50 | M & L preparing old painted surfaces by scraping and removing old paints, rust, etc. from Pre-stressed Concrete Pole (above the Planting Depth and PCC Copings) and Mild Steel Cross Arms, Cable Protection Pipe, Brackets, etc. and applying Two Coats of Synthetic Enamel Painting in alternate Yellow & Black Strips Painting (5 No. Each Strip 300mm wide) and remaining portion of Pole treated with Two Coats of Exterior Weather Proof Paint also including numbering to poles with synthetic enamel paint on black base of size 15 cm x 10 cm and numbering in 8 cm height of number with white paintand Mild Steel Cross Arms, Cable Protection Pipe, Brackets, etc. treated with Two Coats of Aluminium Paintcomplete all as specified and as directed. |
| 51 | Supply and fixing in replacement of Galvanised steel wire, 4mm dia (No 8 SWG) for continuous earth wire and Cradies, hexagonal/rectangular, fabricated with galvanised steel wire 3.15 or 4 mm dia complete all as specified by Engineer-in-Charge. |
| 52 | supply and fixing Cross arms, bracings, supports, clamps and back plates fabricated from structural steel sections conforming to Fe-410-0 or Fe-310-0 grade including necessary nuts, bolts, washers, welding, bending cold or hot, drilling holes for bolts, in any shape and size as directed and including applying two coats of aluminium paint (under & finishing coats) over a coat of red oxide zinc chromate primer on exposed steel surfaces after preparation of surfaces, suppliedand fixed in repair complete all as specified and as directed by Engineer-in-Charge.(Note: - (i) Sizes & types of members and shape of the cross arms etc shall be as required at site all as directed by the Engineer-in-Charge.(ii) Un-exposed steel surfaces shall be given one coat of red-oxide zinc chromate primer only.Cost of the same is included in unit rate of the item and nothing extra shall be paid on this account.) |
| 53 | Supplied and fixed inrepair Pin type, porcelain, vitreous, white, brown or green insulator including one galvanised mild steel spindle, two galvanised iron washers and one galvanised iron nut, 100 mm height, 65 mm dia. for working pressure 1100 volts grade, completeall as specified and as directed by Engineer-in-Charge. |
| 54 | S&F in replacement for shackle type,vitreous, white, brown, or green insulators, including galvanised mild steel strips, washers, insulators bolts,washers and nut for working pressure 1100 Volt, 100mm height 115mm dia, glavanised steel fitting strips of size 21 x 5mm, 14mm dia bolts completeall as specified and as directed by Engineer-in-Charge. Make : Bengal potteries/ Jay Sree/Bikaner ceramics/Mysore. |
| 55 | Danger notice plate of size 20cm x 15 cm x 1.60 mm thick of mild steel sheet, vitreous, enameled white, with letters, figures and conventional skull & bones in signal red colour and fixed with MS clamps made out of 25 mm x 3mm MS flat iron including bolts and nuts of approved size for LT 1100 volts, complete all as specified and as directed by Engineer-in-Charge. |
| 56 | Supplied and fixed in replacement of GI strip of size 32mm x 6.0 mm complete all as specified and as directed by the Engineer-in-Charge. |
| 57 | Earthing complete with galvanized steel earth plate electrode 60 cm x 60 cm x 6 mm thick buried directly in ground (earth pit not less than2.25 m below normal ground level) withtop edge of the plate at a depth not less than 1.5 m below ground level,the earth electrode surrounded by adequate quantity of charcoal dust and salt to a packed thickness of 15 cm on all sides, connected to galvanized earth wire 4 mm dia with and includingnuts, bolts, check nuts & washers of galvanized iron or steel and riveted to earth plate at one end and connecting to main switch board ormetallic bodies of HT/LT equipments etc at the other end, GI wire encased in and including 20 mm boreGIlight grade pipe with all fittings,from top of electrode to body of equipment fixed with and including 25 x 6mm flat iron clamps, bolts, nuts and washer and also including providing watering pipe 20mm bore GI pipe light grade and including funnel, wire mesh, copper lugs etc from bottom of earth pit to top of electrode complete with earth pit in PCC 1:3:6 type C-2 using 40 mm graded crushed stone aggregate and CIcover complete all specified and shown in electrical plate No 05 of SSR Pt-I connectingearth electrode to test point with and includingearthing lead including necessary excavation and earthwork in any type of soil, returning, filling in approved soil and disposal of surplus soil to a distance n.exc 50m, material and labour complete all as specified and as directed by Engineer-in-Charge.(Notes 1. The rate quoted shall be deemed to include for all the above provisions. 2.PCC chamber shall be constructed at least 1.5 m away from the earth electrode and pipe for watering shall be provided in slanting manner). |
| 58 | Ditto all as per Seiral item No 57 here in before but using galvanised iron strip 32 x 6 mm as earthing lead complete all as specified and as diredted by Engineer-In-Charge. |
| 59 | Cutting unaxious green growth and wild grass by manual labour or by machine at Electrical Installation Premises, around Pole, along the boundary Fencing, removing rubbish from the Site of Work and deposting where directed not exc. 100 Metre from the starting Point, complete all as specified and as directed.Note : The Item shall be operated maximum 2 times in the entire period of the Contract and the measurement will be taken every time independently for Payment. |
| 60 | Disconnect the electric supply from Main GO/DOand taking down old existing LooseACSR conductor mounted on Steel/PCC pole4 to 6 Conductorand Re-stringing of existing over head line ACSR conductor/GI wire of any size/type including repair of conductor broken due to wind storm/expansion, contraction etc, on existing LT steel and/orPCC pole including replacement of aluminium binding wire of suitable size andrefixing of all old accessoriescarefully without damaging of insulator etccomplete all as specified and directed by Engineer-in-Charge.(Note: A Team of workers for emergency are avlaible24 Hours) |
| 61 | Ditto all as per Seiral item No 60 here in before butusing7 to 9 Conductor complete all as specified and as diredted by Engineer-In-Charge. |
| 62 | Trimming/pruning of the tree branches comming cross electric power head line HT/LT feeder cleaning the span and making it free from touching the tree branches complete all as specified and as diredted by Engineer-In-Charge.(Note :-(i) All item of LT overhead lines taken together shall be measured as one unit for the payment purpose under this item.(ii) Only such length shall be measured where trees are required to be cut/trimmed as directed by Engineer-In-Charge.(ii) Removing branches from road and diposition at a distance of more than 500 meter) |
| 63 | S & F PVC/ Fibre Separator for LT Lines 1100 Volts OH Conductor 2 Wire system for horizontal spacing of Conductor, fixing with Nuts, Bolts, Washers, etc , complete all as specified and as directed. |
| 64 | S & F PVC/ Fibre Separator for LT Lines 1100 Volts OH Conductor 4 Wire system for horizontal spacing of Conductor, fixing with Nuts, Bolts, Washers, etc., complete all as specified and as directed. |
| 65 | M & L Writing Letter on Steel Tubular/Pre-stressed Concrete Pole (8 Cm in height) with Synthetic Enamel Paint (White) on base of Black Paint15 X 10 Cm , complete all as specified and as directed. |
| 66 | Supply and fixingdecorative light luminaries comprises by spun housing and clear cover post Top LED light , 40 watt with IP 65 protection resistance to impact and corrosion gare free and better uniformity.The fixture shall have a corelated color temperature of at least 5000K and a CRI of minimum 70 .The fixture shall be designed for a system life of 50,000 hours @70% lumen maintenance. Ingress Protection of IP65 (lamp and gear Compartment and Mechanical Impact Resistance Rating of IK >=05. The fixture driver should be withstand up to 440v for 8hrs, two surge proection not less than 4KV one on driver and 5 KVone external surge protection, PF >0.95 and THD<20% .The fixture should comply with the parameters as per IS10322 and for EMI and LM 79testreports complete all as specified and directed by Engr in Charge. |
| 67 | Supply and errecting of decorative steel pole made out of GI section with cast iron embellishments. The poles have diameter 90 mm at TOP, diameter 114 mm in middle and 104 mm at the bottom. Base is made of die cast iron with holes suitable for 20 mm and 24 mm foundation bolts. pole shall be pure polyester based powder coated with high cocorrision resistance and chemical chromatised protection, fixing ofdouble arm decorative bracket suitable to mount on 60mm/90mm pole diameter. The bracket shall be painted with multiple coat of weather resistance polyurethene paint .complete all as specified and directed by engr-in -chargemake :- Decorative pole - Crompton catpart No. Crompton BRASSO decorative pole /Wipro/Philips , Decorative bracket :- Crompton Greaves Catpart No.HM-DECO-DA-NS(DOUBLE ARM)/ Wipro/Philips |