Upgradation Of Sh-262 Tiwadi To Marlegaon Road In Taluka Umarkheddistt. Yavatmalb) Upgradation Of Umarkhed To Takali Road Tq. Umarkhed Dist. Yavatmal Under Package No Adb-Yav(Ii)-09
Tender Value
Ref. Documents
Estimated cost
Bid Submission
31 Jul 2023
0 days left
EMD
9.16 Lakhs
Bank guarantee accepted
Document Fee
17700
Non-refundable
Tender Type
Online
Tender Overview
Organization
Tender ID
Competition Type
NCB
Bidding Type
Tender
Location / State
umarkhed → Maharashtra
EMD Exemption
Not Available
Quantity
Not Available
Website
Contact Person
Address
Project Description
Upgradation Of Sh-262 Tiwadi To Marlegaon Road In Taluka Umarkheddistt. Yavatmalb ) Upgradation Of Umarkhed To Takali Road Tq. Umarkhed Dist. Yavatmal Under Package No Adb-Yav ( Ii ) -09
BOQ
| Sl. No. | Item Description |
| 1 | UPGRADATION OF SH-262 TIWADITO MARLEGAON ROAD, TALUKA - UMARKHED, DISTRICT- YAVATMALCleaning grass and removal of rubbish up to a distance of 30m outside the periphery of the area as per Technical Specification Clause 201 (Item No. 2.1 ) |
| 2 | Scarifying the existing bituminous road surface to a depth of 150 mm and disposal of scarified material with a lift upto 3 m and lead upto 1000 m as per Technical Specification Clause 301.4.Item No. 3.2 UPGRADATION OF SH-262 TIWADITO MARLEGAON ROAD, TALUKA - UMARKHED, DISTRICT- YAVATMAL |
| 3 | Excavation for roadwork in soil with hydraulic excavator of 0.9 cum bucket capacity including cutting and loading in tippers, trimming bottom and side slopes, in accordance with requirements of lines, grades and cross-sections, and transporting to the embankment location with a lift upto 1.5 m and lead upto 1000 m as per Technical Specification Clause 302.3 .(Item No. 3.5(III))UPGRADATION OF SH-262 TIWADITO MARLEGAON ROAD, TALUKA - UMARKHED, DISTRICT- YAVATMAL |
| 4 | Construction of embankment with approved materials deposited at site from roadway cutting and excavation from drain and foundation of other structures graded and compacted to meet requirement of Table 300.1 and 300.2 as per technical specification clause 301.5 ( Item No. 3.3) for P.D. 95% to 100% UPGRADATION OF SH-262 TIWADITO MARLEGAON ROAD, TALUKA - UMARKHED, DISTRICT- YAVATMAL |
| 5 | Construction of embankment with approved material obtained from borrow pits with a lift upto 1.5 m, transporting to site, spreading , grading to required slope and compacting with vibratory roller to meet requirement of Tables 300.1 and 300.2with a lead upto 1000 m as per technical Specification Clause 301.5 ( Item No. 3.4A)UPGRADATION OF SH-262 TIWADITO MARLEGAON ROAD, TALUKA - UMARKHED, DISTRICT- YAVATMAL |
| 6 | Granular Sub-base with Well Graded Material (Table 400.1) Construction of granular sub-base by providing well graded material, spreading in uniform layers with motor grader on prepared surface, mixing by mix in place method with rotavator at OMC, and compacting with vibratory wheel roller to achieve the desired density, complete as per Technical Specification Clause 401..(Item No.4.1 (A) (ii)) UPGRADATION OF SH-262 TIWADITO MARLEGAON ROAD, TALUKA - UMARKHED, DISTRICT- YAVATMAL |
| 7 | Providing, laying, spreading and compacting stone aggregates of specific sizes to Water Bound Macadam specification including spreading in uniform thickness, hand packing, rolling with three wheel roller 80-100 kN static roller in stages to proper grade and camber, applying and brooming, crushable screening to fill-up the interstices of coarse aggregate, watering and compacting to the required density Grading 2 as per Technical Specification Clause 405.(Item No. 4.8 (2) (B))UPGRADATION OF SH-262 TIWADITO MARLEGAON ROAD, TALUKA - UMARKHED, DISTRICT- YAVATMAL |
| 8 | Construction of penetration macadam over prepared base by providing a layer of compacted crushed coarse aggregate using chips spreader with alternate applications of bituminous binder and key aggregates and rolling with a three wheel 80-100 kN static roller to achieve the desired degree of compaction as per Technical Specification Clause 506(Item No. 5.5 (A))UPGRADATION OF SH-262 TIWADITO MARLEGAON ROAD, TALUKA - UMARKHED, DISTRICT- YAVATMAL |
| 9 | Construction of subgrade and earthen shoulders with approved material obtained from borrow pits with all lifts and leads, transporting to site, spreading, grading to required slope and compacting with vibratory roller to meet requirement of Table 300.2 with lead upto 1000 m as per Technical Specification Clause 303.1. (Item No. 3.14 )UPGRADATION OF SH-262 TIWADITO MARLEGAON ROAD, TALUKA - UMARKHED, DISTRICT- YAVATMAL |
| 10 | Providing and applying tack coat on the prepared surface heating by fames in Boiler and spraying bitumen set footed in bitumen boller on B.T. surface 2.5 kg/10 sqm.(VG-30 bulk bitumen rates are considered to arrive at rates)(Item no 140 pg no 30 PWD CSR)UPGRADATION OF SH-262 TIWADITO MARLEGAON ROAD, TALUKA - UMARKHED, DISTRICT- YAVATMAL |
| 11 | Providing, laying and rolling of open-graded premix carpet of 20 mm thickness composed of 13.2 mm to 5.6 mm aggregates either using penetration grade bitumen or emulsion to required line, grade and level to serve as wearing course on a previously prepared base, including mixing in a suitable plant, laying and rolling with a three wheel 80-100 kN static roller capacity, finished to required level and grades to be followed by seal coat of either Type Aor Type B or Type C as per Technical Specification Clause 508. (I.No. 5.9- II (l))UPGRADATION OF SH-262 TIWADITO MARLEGAON ROAD, TALUKA - UMARKHED, DISTRICT- YAVATMAL |
| 12 | Providing and laying Seal Coat sealing the voids in a bituminous surface laid to the specified levels, grade and cross fall using Type B , as per Technical Specification Clause 510. By Mechanical Means.(Item No. 5.12- B/ Case -I, Type B (II) S-65)UPGRADATION OF SH-262 TIWADITO MARLEGAON ROAD, TALUKA - UMARKHED, DISTRICT- YAVATMAL |
| 13 | Supplying and fixing Reinforced cement concrete M-15 grade 5th KM Stone (Precast) of standard design as per IRC:8 fixing in position including painting and printing, etc as per drawing and Technical Specification Clause 1703.(I.No. 10.10 (i)) UPGRADATION OF SH-262 TIWADITO MARLEGAON ROAD, TALUKA - UMARKHED, DISTRICT- YAVATMAL |
| 14 | Supplying and fixing Reinforced cement concrete M15 grade kilometre stone/local stone of standard design as per IRC:8 fixing in position including painting and printing, etc as per drawing and Technical Specification Clause 1703.(I.No. 10.10 (ii) / P.No. 41)UPGRADATION OF SH-262 TIWADITO MARLEGAON ROAD, TALUKA - UMARKHED, DISTRICT- YAVATMAL |
| 15 | Supplying and fixing Reinforced cement concrete M-15 grade 200m Stone (Precast) of standard design as per IRC:8 fixing in position including painting and printing, etc as per drawing and Technical Specification Clause 1703.(I.No. 10.10 (ii,iii))UPGRADATION OF SH-262 TIWADITO MARLEGAON ROAD, TALUKA - UMARKHED, DISTRICT- YAVATMAL |
| 16 | Supplying and fixing Reinforced cement concrete M-15 grade Boundary Pillar/ Local Stone of standard design as per IRC: 25, fixed in position including finishing and lettering but excluding painting as per drawing and Technical Specification Clause 1704.(Item No. 10.11)(By using OPC 43 Grade Cement)UPGRADATION OF SH-262 TIWADITO MARLEGAON ROAD, TALUKA - UMARKHED, DISTRICT- YAVATMAL |
| 17 | Construction of Rounded Hump Type Speed Breaker as per IRC : 99 (1988) for traffic as per specification, including painting, fixing cationary boards etc. complete and as directed by Engineer-in-Charge.UPGRADATION OF SH-262 TIWADITO MARLEGAON ROAD, TALUKA - UMARKHED, DISTRICT- YAVATMAL |
| 18 | Providing and Laying hot applied thermo plastic road marking strip on Bituminous Surface of specified shade/ colour of 2.5mm thick including 1.5 Refractive index reflectorizing glass beads @ 250 gm/ sqm. Thickness of 2.5mm is exclusive of surface applied glass beads as per IRC 35:2015. Initial Dry reflectivity RL shall be >250m cd/ sqm/ lux measured in the initial 7 days and sustained reflectivity RL of 100 mcd/ sqm/ lux and Qd of 100 mcd/ sqm/ lux measured at the end of 2 years by means of a Standard Reflecto meter of Zehntner, Easylux, Delta make capable of measuring RL & QD both according to IRC 35:2015 clause 15.5. The finished surface to be level, uniform, and free from streak sand holes complete as per direction of Engineer-in-charge and inaccordance with applicable specifications. (Refer MORTH Clause 803 for technical Specification and Performance for IRC 35:2015). (SSR It. No. RF 6.12a / P.No. 48)UPGRADATION OF SH-262 TIWADITO MARLEGAON ROAD, TALUKA - UMARKHED, DISTRICT- YAVATMAL |
| 19 | Providing and fixing of typical PMGSY informatory sign board with Logo as per MORD specifications and drawing. Three MS Plates of 1.6 mm thick, top and middle plate duly welded with MS flat iron 25mm x 5m size on back on edges. The lower plate will be welded with MS angle iron frame of 25mm x 25mm x 5mm. The angle iron frame of the lower most plate and flat iron frame of middle plate will be welded to 2 nos. 75mm x 75 mm of 12 SWG sheet tubes posts duly embedded in cement concrete M-15 grade blocks of 450mm x 450mm x 600mm, 600mm below ground level. The top most diamond plate will be welded to middle plate by 47mm x 47mm of 12 SWG steel plate tube. All M.S. will be stove enameled on both sides. Lettering and printing arrows, border etc. will be painted with ready mixed synthetic enamel paint of superior quality in required shade and colour. All sections of framed posts and steel tube will be painted with primer and two coats of epoxy paint as per drawing Clause 1701 and Annexure 1700.1(item no 10.16)UPGRADATION OF SH-262 TIWADITO MARLEGAON ROAD, TALUKA - UMARKHED, DISTRICT- YAVATMAL |
| 20 | Providing and Fixing of Retro Reflectorised 900mm Cautionary sign boards made out of retro reflective sheeting of High Intensity prismatic grade conforming to IRC-67: 2012 & Type IV standards of ASTM D4956-09 specifications, fixed over 4mm thick ACP sheet supported with Back support frame of 25x25x3mm mild steel angle as approved , supported on a mild steel angle iron post 65 mm X 65 mm X 6 mm - 3.5 mtr height,firmly fixed to the ground by means of properly designed foundation with M20 grade cement concrete 45 cm X 45 cm X 60 cm , 60 cm below ground level as per approved drawing. Both border & background shall be retro reflective as per Type IV standards. 7 years Warranty for Retro Reflective Sheeting from the original sheeting manufacturer & a certified copy of three years outdoor exposure report from an independent test lab for the product offered shall be submitted by the contractor(Bottom of the board shall be at least 2.6 mtr. above ground level) Specification: IRC 67:2012. There shall be a stamp behind the ACP sheet carrying the name of the supplier, Name of sheeting Manufacturer, Type of retro reflective sheeting, Installation month & year, Warranty period for retro reflective sheeting.(SoR 2019-20, Item No. 10.2 (B)/ P.No. 39))UPGRADATION OF SH-262 TIWADITO MARLEGAON ROAD, TALUKA - UMARKHED, DISTRICT- YAVATMAL |
| 21 | Providing and erecting direction and place identification retroreflectorised sign as per IRC:67 made of encapsulated lens type reflective sheeting vide Clause 1701.2.3, fixed over aluminium sheeting, 2 mm thick with area not exceeding 0.9 sqm supported on 2 inch dia GI Pipe firmly fixed to the ground by means of properly designed foundation with M-15 grade cement concrete 450 x 450 x 600 mm, 600 mm below ground level as per approved drawing and Tehnical Specification Clause 1701( Item no 10.3)UPGRADATION OF SH-262 TIWADITO MARLEGAON ROAD, TALUKA - UMARKHED, DISTRICT- YAVATMAL |
| 22 | MMGSY / PMGSY Citizen\" s information Board- Providing and fixing of typical PMGSY Retro Reflective information board as per as per section1700 of MORD specifications and latest PMGSY Signage Manual / Circular and drawing. Two ACP (Aluminum Composite Panel) sheets of 4 mm thick, of 900 mm x 750mm size fixed at top & bottom duly rivetted with MS angles of 35 x 35 x 5 mm thick M.S angle shall be welded by two vertical M.S angle of 5 mm thick to 75 mm x 75 mm of 12 SWG square tubes / 75mm Dia Pipe posts duly embedded in cement concrete M-20 grade blocks of 600mm x 600mm x 75mm, below ground level. MMGSY / PMGSY logo, letters and numerals on the ACP should be made up of Retro Reflective sheeting of Class-A / Class-B grade as per the latest MORD section 1700 specifications (Refer Circular no. NRRDA-P013(11)/3/2019-Dir (Tech) dated 02.12.2019). Printing PMGSY Logo/MMGSY Logo/Project description on Class A or Class B type retro reflective sheeting using modern technology printing platform. The printer shall be approved by the retro reflective sheeting manufacturer and printed sign shall conform to retro reflective values as laid down in IRC 67-2012. The inks used for printing shall be eco friendly with VOC emissions complying to UL 2801 standards and specifications for the different kinds of platforms. The printed sign shall be laminated by UV protected laminate and shall carry a warranty of 5 years & 7 years for Class A and Class B sheeting respectively for traffic colors. All sections of framed posts and steel tube will be painted with primer and two coats of epoxy paints as per drawing Clause 1701 and Annexure 1700.1 (10.16). The design, painting and lettering shall be done as per the PMGSY Signage Guidelines Fig.3 and Fig.4 and as directed by Engineer-In-charge. . A warranty for 5 / 7 years for the Retro reflective sheeting for Class-A and Class-B respectively, from original manufacturer shall be submitted by contractorUPGRADATION OF SH-262 TIWADITO MARLEGAON ROAD, TALUKA - UMARKHED, DISTRICT- YAVATMAL |
| 23 | Supplying and Fixing of Molded Shank Raised Pavement Markers / Cat\"s Eye made of polycarbonate and ABS moulded body and reflective panels with micro prismatic lens capable of providing total internal reflection of the light entering the lens face and shall support a load of 16000 kg tested in accordance to ASTM D 4280 Type H and complying to Specifications of Category A of MORTH Circular No RW/NH/33023/10-97 DO III Dt 11.06. 1997. The height, width and length shall not exceed 50 mm, 100 mm and 102 +/- 2 mm and with minimum reflective area of 13 Sqcm on each side and the slope to the base shall be 35 +/- 5 degree. The strength of detachment of the integrated cylindrical shanks, (of diameter not less than 19 +/- 2 mm and height not less than 30+/- 2 mm) from the body is to be a minimum value of 500 Kg. Fixing will be by drilling holes on the road for the shanks to go inside, without nails and using epoxy resin based adhesive as per manufacturer\"s recommendation and complete as directed by the engineer.The contractor shall submit a two year warranty for satisfactory field performance including stipulated retro-reflectance of the reflecting panel, to the Engineer.(SSR 212,P.G. NO.47)UPGRADATION OF SH-262 TIWADITO MARLEGAON ROAD, TALUKA - UMARKHED, DISTRICT- YAVATMAL |
| 24 | Road Delineators: Supplying and installation of delineators (Roadway Indicators, Hazard markers, Object markers) 80 to 100 cm high above ground level, painted black and white in 15cm wide strips, fitted with 80x100mm rectangular or 75mm dia. circular reflectorised panels at the top, buried or pressed into the ground and confirming to I.R.C. 79 and the drawings (SSR It. No. RF 6.15 / P.No. 50) UPGRADATION OF SH-262 TIWADITO MARLEGAON ROAD, TALUKA - UMARKHED, DISTRICT- YAVATMAL |
| 25 | Sign Board of PMGSY Project Information :Providing and fixing of typical retro reflective PMGSY Project informatory sign board with Logo as per section1700 of MORD specifications and latest PMGSY Signage Manual / Circuler and drawing. The board will be a composite unit consisting of ThreePlates ACP (Aluminum Composite Panel), material specificaitons as per clause 17001.3. The top most plate will be of 3mm ACP in diamond shape of 600x600mm size, riveted with MS angle iron frame of 25mmx25mmx5mm size on back on edges. The middle 4mm ACP plate of will be 1200x150mm size riveted with MS angle iron frame of 25mmx25mmx5mm size on back on edges. The main 4mm ACP lower most plate will be 1500mmx600mm size, riveted with MS angle iron frame of 25mmx25mmx5mm size. Riveting of all the sheets over angle and flat iron frame will be done neatly to have plain surface on one side. The angle iron frame of lower most plate and flat iron frame of the middle plate will be welded to twonos. 75mm x75mm x 12 swg sheet tubes posts placed at 1125mm apart centre to centre. the top of the middle plate will be flushed with the top of 75mm dia medium steel tube posts and these posts will be embeded in cement concrete M15 grade block of 450x450x600mm below ground level. The height of the bottom of the lower plate will be 1200mm from normal ground level and the bottom of the middle plate will be 100mm above the toplevel of the lower most plate. the diamond shaped plate mounted over flat angle iron frame will be connected to middle plate by square steel section of 47mmx47mm, thickness12SWG having a spacing of 100mm between the diamond shaped plate and middle plate and this square section will be riveted to the bottom point of the diamond shaped plate. PMGSY logo, letters and numerals on the ACP should be made up of Retro Reflective sheeting of Class-A / Class-B grade as per the latest MORD section 1700 specifications (Refer Circuler no. NRRDA-P013 (11)/ 3/2019-Dir (Tech) dated 02.12.2019). Printing PMGSY Logo Project description on Class A or Class B type retro reflective sheeting using modern technology printing platform. The printer shall be approved by the retro reflective sheeting manufacturer and printed sign shall conform to retro reflective values as laid down in IRC 67-2012. The inks used for printing shall be eco friendly with VOC emissions complying to UL 2801 standards and specifications for the different kinds of platforms. The printed sign shall be laminated by UV protected laminate and shall carry a warranty of 5 years & 7 years for Class A and Class B sheeting respectively for traffic colors. All the section of the frame and posts shall be painted with primer and two coats of epoxy paint. The design, painting and lettering shall be done as per the PMGSY Signage Guidelines Fig.2 and as directed by Engineer-In-charge. . A warranty for 5 / 7 years for the Retro reflective sheeting for Class-A and Class-B respectively, from original manufacturer shall be submitted by contractor. (Item No. 10.21 (A) / P.No. 42)1700 specifications (Refer Circuler no. NRRDA-P013 (11)/ 3/2019-Dir (Tech) dated 02.12.2019). Printing PMGSY Logo Project description on Class A or Class B type retro reflective sheeting using modern technology printing platform. The printer shall be approved by the retro reflective sheeting manufacturer and printed sign shall conform to retro reflective values as laid down in IRC 67-2012. The inks used for printing shall be eco friendly with VOC emissions complying to UL 2801 standards and specifications for the different kinds of platforms. The printed sign shall be laminated by UV protected laminate and shall carry a warranty of 5 years & 7 years for Class A and Class B sheeting respectively for traffic colors. All the section of the frame and posts shall be painted with primer and two coats of epoxy paint. The design, painting and lettering shall be done as per the PMGSY Signage Guidelines Fig.2 and as directed by Engineer-In-charge. . A warranty for 5 / 7 years for the Retro reflective sheeting for Class-A and Class-B respectively, from original manufacturer shall be submitted by contractor. (SoR 2019-20, Item No. 10.21 (A) / P.No. 42) |
| 26 | Providing and layingin brick masonry/stone masonry, plain/reinforced concrete abutment, wing wall, return wall with 100 mm dia PVC pipe extending through the full width of the structures with slope of 1(V):20(H) towards drawing face complete as per drawing and technical specification Clauses 614, 709, 1204.3.7 .(Item No.12.9 (B))UPGRADATION OF SH-262 TIWADITO MARLEGAON ROAD, TALUKA - UMARKHED, DISTRICT- YAVATMAL |
| 27 | Construction of un-reinforced dowel jointed at expansion and construction joint only, plain cement concrete pavement, thickness as per design , over a prepared sub base, with 43 grade cement or any other type as per Clause 1501.2.2 M-30 (Grade) coarse and fine aggregate conforming to IS:383 maximum size of coarse aggregate not exceeding 25 mm mixed in a concrete mixer of not less than 0.2 cum capacity and appropriate weight bacher using approved mix design , laid in approved fixed side formwork ( steel channel , laying and fixing of 125 micron thick polythene film, wedges, steel plates including levelling the formwork as per drawing ), spreading the concrete with showels, rakes, compacted using needle, scared and plate vibrators and finished in continuous operation including provision of contraction and expansion , construction joints, applying debounding strips, primer, sealant, dowel bars, near approaches to bridge/ culvert and coustruction joints , admixtures as approved, curing of concrete slabs for 14 days, using curing compound (where spacified) and water lines and grade as per drawing and technical specification clause 1501 (I.No. 6.4) (By using OPC 43 Grade Cement)UPGRADATION OF SH-262 TIWADITO MARLEGAON ROAD, TALUKA - UMARKHED, DISTRICT- YAVATMAL |
| 28 | Earthwork in excavation for structures as per drawing and technical specifications Clause 305.1 including setting out, construction of shoring and bracing, removal of stumps and other deleterious material and disposal upto a lead of 50m, dressing of sides and bottom and backfilling in trenches with excavated suitable material.(Item No. 11.1 (I) (ii) UPGRADATION OF SH-262 TIWADITO MARLEGAON ROAD, TALUKA - UMARKHED, DISTRICT- YAVATMAL |
| 29 | Ordinary Soil |
| 30 | Soft Rock |
| 31 | Backfilling behind abutment, wing wall and return wall complete as per drawings and technical specification Clause 1204.3.8 (Item No. 12.10 (II) UPGRADATION OF SH-262 TIWADITO MARLEGAON ROAD, TALUKA - UMARKHED, DISTRICT- YAVATMAL |
| 32 | Providing concrete for plain cement concrete M-10in open foundations complete as per drawings and Technical Specification Clauses 802, 803, 1202 and 1203.(Item No. 11.4 (I) (i)) (By using OPC 43 Grade Cement)UPGRADATION OF SH-262 TIWADITO MARLEGAON ROAD, TALUKA - UMARKHED, DISTRICT- YAVATMAL |
| 33 | Fillling in foundation trenches as per drawing and technical specification Clause 305.3.9 Rubble filling (Item No. 11.2 (II))UPGRADATION OF SH-262 TIWADITO MARLEGAON ROAD, TALUKA - UMARKHED, DISTRICT- YAVATMAL |
| 34 | Providing concrete for plain cement concrete M-15 in foundations complete as per drawings and Technical Specification Clauses 802, 803, 1202 and 1203.(Item No. 11.4 (ii) (i))UPGRADATION OF SH-262 TIWADITO MARLEGAON ROAD, TALUKA - UMARKHED, DISTRICT- YAVATMAL |
| 35 | Providing Plain/reinforced cement concretein substructure complete as per drawings and technical specification Clauses 802, 804, 805, 806, 807, 1202 ans 1204(Item No. 12.5 (I)(i)) (M-15)UPGRADATION OF SH-262 TIWADITO MARLEGAON ROAD, TALUKA - UMARKHED, DISTRICT- YAVATMAL |
| 36 | Providing and layingR.C.C. M-20 Grade cement concrete in substructure complete as per drawings and technical specification Clause 802, 804, 805, 806, 807, 1202 and 1204 (Item No. 12.5 (III))UPGRADATION OF SH-262 TIWADITO MARLEGAON ROAD, TALUKA - UMARKHED, DISTRICT- YAVATMAL |
| 37 | Providing and laying reinforced cement concrete M-20 in superstructureas per drawing and Technical Specifications Clauses 800, 1205.4 and 1205.5 (Item No. 13.1 (I) (iii)/ P.No. 52)UPGRADATION OF SH-262 TIWADITO MARLEGAON ROAD, TALUKA - UMARKHED, DISTRICT- YAVATMAL |
| 38 | Providing and laying reinforced cement concrete M-25 in superstructure as per drawing and technical specifications Clauses 800, 1205.4 and 1205.5(Item No. 13.1(II) / P.No. 52) UPGRADATION OF SH-262 TIWADITO MARLEGAON ROAD, TALUKA - UMARKHED, DISTRICT- YAVATMAL |
| 39 | Supplying fitting, and placing HYSD bar reinforcement (Fe 415) in substructure complete as per drawing and technical spcifications Clauses 1002, 1005, 1010 and 1202 (Item No. 12.7 ) |
| 40 | Supplying, fitting and placing HYSD bar reinforcement (Fe 415) SAIL/TATA/JINDAL/RINL/ELECTRATERM or equivalent in substructrue complete as per drawings and technical specification Clauses 1002, 1005, 1010 & 1202 (Item No. 12.6)UPGRADATION OF SH-262 TIWADITO MARLEGAON ROAD, TALUKA - UMARKHED, DISTRICT- YAVATMAL |
| 41 | Providing and laying reinforced cement concrete pipe NP2 for culverts on first class bedding of granular material and single row including fixing collar with cement mortar 1:2 but excluding excavation, protection works, backfilling, concrete and masonry works in head walls and parapets. Clause 1106. (Item No. 9.4 (D) / P.No. 34)UPGRADATION OF SH-262 TIWADITO MARLEGAON ROAD, TALUKA - UMARKHED, DISTRICT- YAVATMAL |
| 42 | Dismantling of existing structures like culverts, bridges, retaining walls and other structure comprising of masonry, cement concrete, wood work, steel work, including T&P and scaffolding wherever necessary, sorting the dismantled material, disposal of unserviceable material and stacking the serviceable material with all lifts and lead of 1000m as per Technical Specification Clause 202. (Item No. 2.5 (II) (I)A)UPGRADATION OF SH-262 TIWADITO MARLEGAON ROAD, TALUKA - UMARKHED, DISTRICT- YAVATMAL |
| 43 | Removing all types of Hume pipes and stacking within a lead of 1000 m including Earthwork and Dismantalling of Masnory Works as per Technical Specification Clause 202 (Item No. 2.13 UPGRADATION OF SH-262 TIWADITO MARLEGAON ROAD, TALUKA - UMARKHED, DISTRICT- YAVATMAL Above 900 MM DIA |
| 44 | Providing and laying reinforced cement concrete pipe NP3 for culverts on first class bedding of granular material and single row including fixing collar with cement mortar 1:2 but excluding excavation, protection works, backfilling, concrete and masonry works in head walls and parapets. Clause 1106. As per(Item No. 9.3)UPGRADATION OF SH-262 TIWADITO MARLEGAON ROAD, TALUKA - UMARKHED, DISTRICT- YAVATMAL |
| 45 | Providingtarpaperbearing of approved quality in proper size etc. complete.(Item No. 13.16 (V) / P.No. 54)UPGRADATION OF SH-262 TIWADITO MARLEGAON ROAD, TALUKA - UMARKHED, DISTRICT- YAVATMAL |
| 46 | Providing and laying filter media with granular crushed aggregates as per specifications to a thickness of not less than 600 mm with smaller size towards the soil and bigger size towards the wall and providing over the entire surface behind abutment, wing wall, return wallto the full height compacted to firm condition complete as per drawing and technical specification Clause 1204.3.8 (Item No. 12.11 ) UPGRADATION OF SH-262 TIWADITO MARLEGAON ROAD, TALUKA - UMARKHED, DISTRICT- YAVATMAL |
| 47 | Construction of flexible apron 1 m thick comprising of loose stone boulders weighing not less then 25 kg beyond curtain wall (Item No. 14.10 )UPGRADATION OF SH-262 TIWADITO MARLEGAON ROAD, TALUKA - UMARKHED, DISTRICT- YAVATMAL |
| 48 | Providing weepholes in plain concrete abutment, wing wall, return wall with 100 mm dia AC pipe extending through the full width of the structures with slope of 1(v) :20(h) towards drawing face complete as per drawing and technical specification Clauses 614, 709, 1204.3.7(Item No. 12.9 (a) UPGRADATION OF SH-262 TIWADITO MARLEGAON ROAD, TALUKA - UMARKHED, DISTRICT- YAVATMAL |
| 49 | Providing and laying pitching on slopes laid over prepared filter media as per drawing and technical specifications Clause 1302 (Item No. 14.5)UPGRADATION OF SH-262 TIWADITO MARLEGAON ROAD, TALUKA - UMARKHED, DISTRICT- YAVATMAL |
| 50 | Expansion Joint with 25mm thick bituminous pad (Item No. 13.16 (II-A) P.No. 54)UPGRADATION OF SH-262 TIWADITO MARLEGAON ROAD, TALUKA - UMARKHED, DISTRICT- YAVATMAL |
| 51 | Painting two coats including prime coat with epoxy paint of approved brand on concrete/steel surfaces after through cleaning of surface to give an even shade as per drawing and Technical Specification Clause 1701(Item 10.7/page 40)UPGRADATION OF SH-262 TIWADITO MARLEGAON ROAD, TALUKA - UMARKHED, DISTRICT- YAVATMAL |
| 52 | Providing and fixing in position railing consisting of IS Rolled steel joist posts designation IS MB 100 (100 x 75) at 2.5m interval and three rows of 50 mm dia steel pipes ( light ) including fixing in position on bridge deck complete as per drawing and technical specification Clause 1208.2 (Item No. 13.8)UPGRADATION OF SH-262 TIWADITO MARLEGAON ROAD, TALUKA - UMARKHED, DISTRICT- YAVATMAL |
| 53 | UPGRADATION OF UMARKHED TO TAKALI, TALUKA - UMARKHED, DISTRICT- YAVATMALCleaning grass and removal of rubbish up to a distance of 30m outside the periphery of the area as per Technical Specification Clause 201 (Item No. 2.1 ) |
| 54 | Scarifying the existing bituminous road surface to a depth of 150 mm and disposal of scarified material with a lift upto 3 m and lead upto 1000 m as per Technical Specification Clause 301.4.Item No. 3.2UPGRADATION OF UMARKHED TO TAKALI, TALUKA - UMARKHED, DISTRICT- YAVATMALPACKAGE NO-ADB(II)-09 |
| 55 | Excavation for roadwork in soil with hydraulic excavator of 0.9 cum bucket capacity including cutting and loading in tippers, trimming bottom and side slopes, in accordance with requirements of lines, grades and cross-sections, and transporting to the embankment location with a lift upto 1.5 m and lead upto 1000 m as per Technical Specification Clause 302.3 .(Item No. 3.5(III))UPGRADATION OF UMARKHED TO TAKALI, TALUKA - UMARKHED, DISTRICT- YAVATMAL |
| 56 | Construction of embankment with approved materials deposited at site from roadway cutting and excavation from drain and foundation of other structures graded and compacted to meet requirement of Table 300.1 and 300.2 as per technical specification clause 301.5 ( Item No. 3.3) for P.D. 95% to 100% UPGRADATION OF UMARKHED TO TAKALI, TALUKA - UMARKHED, DISTRICT- YAVATMAL |
| 57 | Construction of embankment with approved material obtained from borrow pits with a lift upto 1.5 m, transporting to site, spreading , grading to required slope and compacting with vibratory roller to meet requirement of Tables 300.1 and 300.2with a lead upto 1000 m as per technical Specification Clause 301.5 ( Item No. 3.4A))UPGRADATION OF UMARKHED TO TAKALI, TALUKA - UMARKHED, DISTRICT- YAVATMAL |
| 58 | Granular Sub-base with Well Graded Material (Table 400.1) Construction of granular sub-base by providing well graded material, spreading in uniform layers with motor grader on prepared surface, mixing by mix in place method with rotavator at OMC, and compacting with vibratory wheel roller to achieve the desired density, complete as per Technical Specification Clause 401..(Item No.4.1 (A) (ii)))UPGRADATION OF UMARKHED TO TAKALI, TALUKA - UMARKHED, DISTRICT- YAVATMAL |
| 59 | Providing, laying, spreading and compacting stone aggregates of specific sizes to Water Bound Macadam specification including spreading in uniform thickness, hand packing, rolling with three wheel roller 80-100 kN static roller in stages to proper grade and camber, applying and brooming, crushable screening to fill-up the interstices of coarse aggregate, watering and compacting to the required density Grading 2 as per Technical Specification Clause 405.(Item No. 4.8 (2) (B)))UPGRADATION OF UMARKHED TO TAKALI, TALUKA - UMARKHED, DISTRICT- YAVATMAL |
| 60 | Construction of penetration macadam over prepared base by providing a layer of compacted crushed coarse aggregate using chips spreader with alternate applications of bituminous binder and key aggregates and rolling with a three wheel 80-100 kN static roller to achieve the desired degree of compaction as per Technical Specification Clause 506(Item No. 5.5 (A)))UPGRADATION OF UMARKHED TO TAKALI, TALUKA - UMARKHED, DISTRICT- YAVATMAL |
| 61 | Construction of subgrade and earthen shoulders with approved material obtained from borrow pits with all lifts and leads, transporting to site, spreading, grading to required slope and compacting with vibratory roller to meet requirement of Table 300.2 with lead upto 1000 m as per Technical Specification Clause 303.1. (Item No. 3.14 )UPGRADATION OF UMARKHED TO TAKALI, TALUKA - UMARKHED, DISTRICT- YAVATMAL |
| 62 | Providing and applying tack coat on the prepared surface heating by fames in Boiler and spraying bitumen set footed in bitumen boller on B.T. surface 2.5 kg/10 sqm.(VG-30 bulk bitumen rates are considered to arrive at rates)(Item no 140 pg no 30 PWD CSR))UPGRADATION OF UMARKHED TO TAKALI, TALUKA - UMARKHED, DISTRICT- YAVATMAL |
| 63 | Providing, laying and rolling of open-graded premix carpet of 20 mm thickness composed of 13.2 mm to 5.6 mm aggregates either using penetration grade bitumen or emulsion to required line, grade and level to serve as wearing course on a previously prepared base, including mixing in a suitable plant, laying and rolling with a three wheel 80-100 kN static roller capacity, finished to required level and grades to be followed by seal coat of either Type Aor Type B or Type C as per Technical Specification Clause 508. (I.No. 5.9- II (l)))UPGRADATION OF UMARKHED TO TAKALI, TALUKA - UMARKHED, DISTRICT- YAVATMAL |
| 64 | Providing and laying Seal Coat sealing the voids in a bituminous surface laid to the specified levels, grade and cross fall using Type B , as per Technical Specification Clause 510. By Mechanical Means.(Item No. 5.12- B/ Case -I, Type B (II) S-65))UPGRADATION OF UMARKHED TO TAKALI, TALUKA - UMARKHED, DISTRICT- YAVATMAL |
| 65 | Supplying and fixing Reinforced cement concrete M-15 grade 5th KM Stone (Precast) of standard design as per IRC:8 fixing in position including painting and printing, etc as per drawing and Technical Specification Clause 1703.(I.No. 10.10 (i)) )UPGRADATION OF UMARKHED TO TAKALI, TALUKA - UMARKHED, DISTRICT- YAVATMAL |
| 66 | Supplying and fixing Reinforced cement concrete M15 grade kilometre stone/local stone of standard design as per IRC:8 fixing in position including painting and printing, etc as per drawing and Technical Specification Clause 1703.(I.No. 10.10 (ii) / P.No. 41))UPGRADATION OF UMARKHED TO TAKALI, TALUKA - UMARKHED, DISTRICT- YAVATMAL |
| 67 | Supplying and fixing Reinforced cement concrete M-15 grade 200m Stone (Precast) of standard design as per IRC:8 fixing in position including painting and printing, etc as per drawing and Technical Specification Clause 1703.(I.No. 10.10 (ii,iii)))UPGRADATION OF UMARKHED TO TAKALI, TALUKA - UMARKHED, DISTRICT- YAVATMAL |
| 68 | Supplying and fixing Reinforced cement concrete M-15 grade Boundary Pillar/ Local Stone of standard design as per IRC: 25, fixed in position including finishing and lettering but excluding painting as per drawing and Technical Specification Clause 1704.(Item No. 10.11)(By using OPC 43 Grade Cement))UPGRADATION OF UMARKHED TO TAKALI, TALUKA - UMARKHED, DISTRICT- YAVATMAL |
| 69 | Construction of Rounded Hump Type Speed Breaker as per IRC : 99 (1988) for traffic as per specification, including painting, fixing cationary boards etc. complete and as directed by Engineer-in-Charge.UPGRADATION OF UMARKHED TO TAKALI, TALUKA - UMARKHED, DISTRICT- YAVATMAL |
| 70 | Providing and Laying hot applied thermo plastic road marking strip on Bituminous Surface of specified shade/ colour of 2.5mm thick including 1.5 Refractive index reflectorizing glass beads @ 250 gm/ sqm. Thickness of 2.5mm is exclusive of surface applied glass beads as per IRC 35:2015. Initial Dry reflectivity RL shall be >250m cd/ sqm/ lux measured in the initial 7 days and sustained reflectivity RL of 100 mcd/ sqm/ lux and Qd of 100 mcd/ sqm/ lux measured at the end of 2 years by means of a Standard Reflecto meter of Zehntner, Easylux, Delta make capable of measuring RL & QD both according to IRC 35:2015 clause 15.5. The finished surface to be level, uniform, and free from streak sand holes complete as per direction of Engineer-in-charge and inaccordance with applicable specifications. (Refer MORTH Clause 803 for technical Specification and Performance for IRC 35:2015). (SSR It. No. RF 6.12a / P.No. 48)UPGRADATION OF UMARKHED TO TAKALI, TALUKA - UMARKHED, DISTRICT- YAVATMAL |
| 71 | Providing and fixing of typical PMGSY informatory sign board with Logo as per MORD specifications and drawing. Three MS Plates of 1.6 mm thick, top and middle plate duly welded with MS flat iron 25mm x 5m size on back on edges. The lower plate will be welded with MS angle iron frame of 25mm x 25mm x 5mm. The angle iron frame of the lower most plate and flat iron frame of middle plate will be welded to 2 nos. 75mm x 75 mm of 12 SWG sheet tubes posts duly embedded in cement concrete M-15 grade blocks of 450mm x 450mm x 600mm, 600mm below ground level. The top most diamond plate will be welded to middle plate by 47mm x 47mm of 12 SWG steel plate tube. All M.S. will be stove enameled on both sides. Lettering and printing arrows, border etc. will be painted with ready mixed synthetic enamel paint of superior quality in required shade and colour. All sections of framed posts and steel tube will be painted with primer and two coats of epoxy paint as per drawing Clause 1701 and Annexure 1700.1(item no 10.16))UPGRADATION OF UMARKHED TO TAKALI, TALUKA - UMARKHED, DISTRICT- YAVATMAL |
| 72 | Providing and Fixing of Retro Reflectorised 900mm Cautionary sign boards made out of retro reflective sheeting of High Intensity prismatic grade conforming to IRC-67: 2012 & Type IV standards of ASTM D4956-09 specifications, fixed over 4mm thick ACP sheet supported with Back support frame of 25x25x3mm mild steel angle as approved , supported on a mild steel angle iron post 65 mm X 65 mm X 6 mm - 3.5 mtr height,firmly fixed to the ground by means of properly designed foundation with M20 grade cement concrete 45 cm X 45 cm X 60 cm , 60 cm below ground level as per approved drawing. Both border & background shall be retro reflective as per Type IV standards. 7 years Warranty for Retro Reflective Sheeting from the original sheeting manufacturer & a certified copy of three years outdoor exposure report from an independent test lab for the product offered shall be submitted by the contractor(Bottom of the board shall be at least 2.6 mtr. above ground level) Specification: IRC 67:2012. There shall be a stamp behind the ACP sheet carrying the name of the supplier, Name of sheeting Manufacturer, Type of retro reflective sheeting, Installation month & year, Warranty period for retro reflective sheeting.(SoR 2019-20, Item No. 10.2 (B)/ P.No. 39)UPGRADATION OF UMARKHED TO TAKALI, TALUKA - UMARKHED, DISTRICT- YAVATMAL |
| 73 | Providing and erecting direction and place identification retroreflectorised sign as per IRC:67 made of encapsulated lens type reflective sheeting vide Clause 1701.2.3, fixed over aluminium sheeting, 2 mm thick with area not exceeding 0.9 sqm supported on 2 inch dia GI Pipe firmly fixed to the ground by means of properly designed foundation with M-15 grade cement concrete 450 x 450 x 600 mm, 600 mm below ground level as per approved drawing and Tehnical Specification Clause 1701( Item no 10.3)UPGRADATION OF UMARKHED TO TAKALI, TALUKA - UMARKHED, DISTRICT- YAVATMAL |
| 74 | MMGSY / PMGSY Citizen\" s information Board- Providing and fixing of typical PMGSY Retro Reflective information board as per as per section1700 of MORD specifications and latest PMGSY Signage Manual / Circular and drawing. Two ACP (Aluminum Composite Panel) sheets of 4 mm thick, of 900 mm x 750mm size fixed at top & bottom duly rivetted with MS angles of 35 x 35 x 5 mm thick M.S angle shall be welded by two vertical M.S angle of 5 mm thick to 75 mm x 75 mm of 12 SWG square tubes / 75mm Dia Pipe posts duly embedded in cement concrete M-20 grade blocks of 600mm x 600mm x 75mm, below ground level. MMGSY / PMGSY logo, letters and numerals on the ACP should be made up of Retro Reflective sheeting of Class-A / Class-B grade as per the latest MORD section 1700 specifications (Refer Circular no. NRRDA-P013(11)/3/2019-Dir (Tech) dated 02.12.2019). Printing PMGSY Logo/MMGSY Logo/Project description on Class A or Class B type retro reflective sheeting using modern technology printing platform. The printer shall be approved by the retro reflective sheeting manufacturer and printed sign shall conform to retro reflective values as laid down in IRC 67-2012. The inks used for printing shall be eco friendly with VOC emissions complying to UL 2801 standards and specifications for the different kinds of platforms. The printed sign shall be laminated by UV protected laminate and shall carry a warranty of 5 years & 7 years for Class A and Class B sheeting respectively for traffic colors. All sections of framed posts and steel tube will be painted with primer and two coats of epoxy paints as per drawing Clause 1701 and Annexure 1700.1 (10.16). The design, painting and lettering shall be done as per the PMGSY Signage Guidelines Fig.3 and Fig.4 and as directed by Engineer-In-charge. . A warranty for 5 / 7 years for the Retro reflective sheeting for Class-A and Class-B respectively, from original manufacturer shall be submitted by contractorn UPGRADATION OF UMARKHED TO TAKALI, TALUKA - UMARKHED, DISTRICT- YAVATMAL |
| 75 | Supplying and Fixing of Molded Shank Raised Pavement Markers / Cat\"s Eye made of polycarbonate and ABS moulded body and reflective panels with micro prismatic lens capable of providing total internal reflection of the light entering the lens face and shall support a load of 16000 kg tested in accordance to ASTM D 4280 Type H and complying to Specifications of Category A of MORTH Circular No RW/NH/33023/10-97 DO III Dt 11.06. 1997. The height, width and length shall not exceed 50 mm, 100 mm and 102 +/- 2 mm and with minimum reflective area of 13 Sqcm on each side and the slope to the base shall be 35 +/- 5 degree. The strength of detachment of the integrated cylindrical shanks, (of diameter not less than 19 +/- 2 mm and height not less than 30+/- 2 mm) from the body is to be a minimum value of 500 Kg. Fixing will be by drilling holes on the road for the shanks to go inside, without nails and using epoxy resin based adhesive as per manufacturer\"s recommendation and complete as directed by the engineer.The contractor shall submit a two year warranty for satisfactory field performance including stipulated retro-reflectance of the reflecting panel, to the Engineer.(SSR 212,P.G. NO.47))UPGRADATION OF UMARKHED TO TAKALI, TALUKA - UMARKHED, DISTRICT- YAVATMAL |
| 76 | Road Delineators: Supplying and installation of delineators (Roadway Indicators, Hazard markers, Object markers) 80 to 100 cm high above ground level, painted black and white in 15cm wide strips, fitted with 80x100mm rectangular or 75mm dia. circular reflectorised panels at the top, buried or pressed into the ground and confirming to I.R.C. 79 and the drawings (SSR It. No. RF 6.15 / P.No. 50) )UPGRADATION OF UMARKHED TO TAKALI, TALUKA - UMARKHED, DISTRICT- YAVATMAL |
| 77 | Sign Board of PMGSY Project Information :Providing and fixing of typical retro reflective PMGSY Project informatory sign board with Logo as per section1700 of MORD specifications and latest PMGSY Signage Manual / Circuler and drawing. The board will be a composite unit consisting of ThreePlates ACP (Aluminum Composite Panel), material specificaitons as per clause 17001.3. The top most plate will be of 3mm ACP in diamond shape of 600x600mm size, riveted with MS angle iron frame of 25mmx25mmx5mm size on back on edges. The middle 4mm ACP plate of will be 1200x150mm size riveted with MS angle iron frame of 25mmx25mmx5mm size on back on edges. The main 4mm ACP lower most plate will be 1500mmx600mm size, riveted with MS angle iron frame of 25mmx25mmx5mm size. Riveting of all the sheets over angle and flat iron frame will be done neatly to have plain surface on one side. The angle iron frame of lower most plate and flat iron frame of the middle plate will be welded to twonos. 75mm x75mm x 12 swg sheet tubes posts placed at 1125mm apart centre to centre. the top of the middle plate will be flushed with the top of 75mm dia medium steel tube posts and these posts will be embeded in cement concrete M15 grade block of 450x450x600mm below ground level. The height of the bottom of the lower plate will be 1200mm from normal ground level and the bottom of the middle plate will be 100mm above the toplevel of the lower most plate. the diamond shaped plate mounted over flat angle iron frame will be connected to middle plate by square steel section of 47mmx47mm, thickness12SWG having a spacing of 100mm between the diamond shaped plate and middle plate and this square section will be riveted to the bottom point of the diamond shaped plate. PMGSY logo, letters and numerals on the ACP should be made up of Retro Reflective sheeting of Class-A / Class-B grade as per the latest MORD section 1700 specifications (Refer Circuler no. NRRDA-P013 (11)/ 3/2019-Dir (Tech) dated 02.12.2019). Printing PMGSY Logo Project description on Class A or Class B type retro reflective sheeting using modern technology printing platform. The printer shall be approved by the retro reflective sheeting manufacturer and printed sign shall conform to retro reflective values as laid down in IRC 67-2012. The inks used for printing shall be eco friendly with VOC emissions complying to UL 2801 standards and specifications for the different kinds of platforms. The printed sign shall be laminated by UV protected laminate and shall carry a warranty of 5 years & 7 years for Class A and Class B sheeting respectively for traffic colors. All the section of the frame and posts shall be painted with primer and two coats of epoxy paint. The design, painting and lettering shall be done as per the PMGSY Signage Guidelines Fig.2 and as directed by Engineer-In-charge. . A warranty for 5 / 7 years for the Retro reflective sheeting for Class-A and Class-B respectively, from original manufacturer shall be submitted by contractor. (Item No. 10.21 (A) / P.No. 42)1700 specifications (Refer Circuler no. NRRDA-P013 (11)/ 3/2019-Dir (Tech) dated 02.12.2019). Printing PMGSY Logo Project description on Class A or Class B type retro reflective sheeting using modern technology printing platform. The printer shall be approved by the retro reflective sheeting manufacturer and printed sign shall conform to retro reflective values as laid down in IRC 67-2012. The inks used for printing shall be eco friendly with VOC emissions complying to UL 2801 standards and specifications for the different kinds of platforms. The printed sign shall be laminated by UV protected laminate and shall carry a warranty of 5 years & 7 years for Class A and Class B sheeting respectively for traffic colors. All the section of the frame and posts shall be painted with primer and two coats of epoxy paint. The design, painting and lettering shall be done as per the PMGSY Signage Guidelines Fig.2 and as directed by Engineer-In-charge. . A warranty for 5 / 7 years for the Retro reflective sheeting for Class-A and Class-B respectively, from original manufacturer shall be submitted by contractor. (SoR 2019-20, Item No. 10.21 (A) / P.No. 42)UPGRADATION OF UMARKHED TO TAKALI, TALUKA - UMARKHED, DISTRICT- YAVATMAL |
| 78 | Providing and layingin brick masonry/stone masonry, plain/reinforced concrete abutment, wing wall, return wall with 100 mm dia PVC pipe extending through the full width of the structures with slope of 1(V):20(H) towards drawing face complete as per drawing and technical specification Clauses 614, 709, 1204.3.7 .(Item No.12.9 (B))UPGRADATION OF UMARKHED TO TAKALI, TALUKA - UMARKHED, DISTRICT- YAVATMAL |
| 79 | Construction of un-reinforced dowel jointed at expansion and construction joint only, plain cement concrete pavement, thickness as per design , over a prepared sub base, with 43 grade cement or any other type as per Clause 1501.2.2 M-30 (Grade) coarse and fine aggregate conforming to IS:383 maximum size of coarse aggregate not exceeding 25 mm mixed in a concrete mixer of not less than 0.2 cum capacity and appropriate weight bacher using approved mix design , laid in approved fixed side formwork ( steel channel , laying and fixing of 125 micron thick polythene film, wedges, steel plates including levelling the formwork as per drawing ), spreading the concrete with showels, rakes, compacted using needle, scared and plate vibrators and finished in continuous operation including provision of contraction and expansion , construction joints, applying debounding strips, primer, sealant, dowel bars, near approaches to bridge/ culvert and coustruction joints , admixtures as approved, curing of concrete slabs for 14 days, using curing compound (where spacified) and water lines and grade as per drawing and technical specification clause 1501 (I.No. 6.4) (By using OPC 43 Grade Cement)UPGRADATION OF UMARKHED TO TAKALI, TALUKA - UMARKHED, DISTRICT- YAVATMAL |
| 80 | Earthwork in excavation for structures as per drawing and technical specifications Clause 305.1 including setting out, construction of shoring and bracing, removal of stumps and other deleterious material and disposal upto a lead of 50m, dressing of sides and bottom and backfilling in trenches with excavated suitable material.(Item No. 11.1 (I) (ii))UPGRADATION OF UMARKHED TO TAKALI, TALUKA - UMARKHED, DISTRICT- YAVATMAL |
| 81 | Ordinary Soil |
| 82 | Soft Rock |
| 83 | Backfilling behind abutment, wing wall and return wall complete as per drawings and technical specification Clause 1204.3.8 (Item No. 12.10 (II) )UPGRADATION OF UMARKHED TO TAKALI, TALUKA - UMARKHED, DISTRICT- YAVATMAL |
| 84 | Providing concrete for plain cement concrete M-10in open foundations complete as per drawings and Technical Specification Clauses 802, 803, 1202 and 1203.(Item No. 11.4 (I) (i)) (By using OPC 43 Grade Cement)UPGRADATION OF UMARKHED TO TAKALI, TALUKA - UMARKHED, DISTRICT- YAVATMAL |
| 85 | Fillling in foundation trenches as per drawing and technical specification Clause 305.3.9 Rubble filling (Item No. 11.2 (II)))UPGRADATION OF UMARKHED TO TAKALI, TALUKA - UMARKHED, DISTRICT- YAVATMAL |
| 86 | Providing and laying reinforced cement concrete M-20 in superstructureas per drawing and Technical Specifications Clauses 800, 1205.4 and 1205.5 (Item No. 13.1 (I) (iii)/ P.No. 52))UPGRADATION OF UMARKHED TO TAKALI, TALUKA - UMARKHED, DISTRICT- YAVATMAL |
| 87 | Providing and laying reinforced cement concrete M-25 in superstructure as per drawing and technical specifications Clauses 800, 1205.4 and 1205.5(Item No. 13.1(II) / P.No. 52) )UPGRADATION OF UMARKHED TO TAKALI, TALUKA - UMARKHED, DISTRICT- YAVATMAL |
| 88 | Providing concrete for plain cement concrete M-15 in foundations complete as per drawings and Technical Specification Clauses 802, 803, 1202 and 1203.(Item No. 11.4 (ii) (i))UPGRADATION OF UMARKHED TO TAKALI, TALUKA - UMARKHED, DISTRICT- YAVATMAL |
| 89 | Providing Plain/reinforced cement concretein substructure complete as per drawings and technical specification Clauses 802, 804, 805, 806, 807, 1202 ans 1204(Item No. 12.5 (I)(i)) (M-15))UPGRADATION OF UMARKHED TO TAKALI, TALUKA - UMARKHED, DISTRICT- YAVATMAL |
| 90 | Supplying fitting, and placing HYSD bar reinforcement (Fe 415) in Foundation complete as per drawing and technical spcifications Clauses 1002, 1005, 1010 and 1202 (Item No. 11.7 )UPGRADATION OF UMARKHED TO TAKALI, TALUKA - UMARKHED, DISTRICT- YAVATMAL |
| 91 | Providing and laying reinforced cement concrete pipe NP2 for culverts on first class bedding of granular material and single row including fixing collar with cement mortar 1:2 but excluding excavation, protection works, backfilling, concrete and masonry works in head walls and parapets. Clause 1106. (Item No. 9.4 (D) / P.No. 34)UPGRADATION OF UMARKHED TO TAKALI, TALUKA - UMARKHED, DISTRICT- YAVATMAL |
| 92 | Dismantling of existing structures like culverts, bridges, retaining walls and other structure comprising of masonry, cement concrete, wood work, steel work, including T&P and scaffolding wherever necessary, sorting the dismantled material, disposal of unserviceable material and stacking the serviceable material with all lifts and lead of 1000m as per Technical Specification Clause 202. (Item No. 2.5 (II) (I)A)UPGRADATION OF UMARKHED TO TAKALI, TALUKA - UMARKHED, DISTRICT- YAVATMAL |
| 93 | Removing all types of Hume pipes and stacking within a lead of 1000 m including Earthwork and Dismantalling of Masnory Works as per Technical Specification Clause 202 (Item No. 2.13)UPGRADATION OF UMARKHED TO TAKALI, TALUKA - UMARKHED, DISTRICT- YAVATMALAbove 900 MM DIA |
| 94 | Providing and laying reinforced cement concrete pipe NP3 for culverts on first class bedding of granular material and single row including fixing collar with cement mortar 1:2 but excluding excavation, protection works, backfilling, concrete and masonry works in head walls and parapets. Clause 1106. As per(Item No. 9.3)UPGRADATION OF UMARKHED TO TAKALI, TALUKA - UMARKHED, DISTRICT- YAVATMAL |
| 95 | Providingtarpaperbearing of approved quality in proper size etc. complete.(Item No. 13.16 (V) / P.No. 54)UPGRADATION OF UMARKHED TO TAKALI, TALUKA - UMARKHED, DISTRICT- YAVATMAL |
| 96 | Providing and laying filter media with granular crushed aggregates as per specifications to a thickness of not less than 600 mm with smaller size towards the soil and bigger size towards the wall and providing over the entire surface behind abutment, wing wall, return wallto the full height compacted to firm condition complete as per drawing and technical specification Clause 1204.3.8 (Item No. 12.11 )UPGRADATION OF UMARKHED TO TAKALI, TALUKA - UMARKHED, DISTRICT- YAVATMAL |
| 97 | Construction of flexible apron 1 m thick comprising of loose stone boulders weighing not less then 25 kg beyond curtain wall (Item No. 14.10 )UPGRADATION OF UMARKHED TO TAKALI, TALUKA - UMARKHED, DISTRICT- YAVATMAL |
| 98 | Providing weepholes in plain concrete abutment, wing wall, return wall with 100 mm dia AC pipe extending through the full width of the structures with slope of 1(v) :20(h) towards drawing face complete as per drawing and technical specification Clauses 614, 709, 1204.3.7(Item No. 12.9 (a) UPGRADATION OF UMARKHED TO TAKALI, TALUKA - UMARKHED, DISTRICT- YAVATMAL |
| 99 | Painting two coats including prime coat with epoxy paint of approved brand on concrete/steel surfaces after through cleaning of surface to give an even shade as per drawing and Technical Specification Clause 1701(Item 10.7/page 40)UPGRADATION OF UMARKHED TO TAKALI, TALUKA - UMARKHED, DISTRICT- YAVATMAL |
| 100 | Providing and laying pitching on slopes laid over prepared filter media as per drawing and technical specifications Clause 1302 (Item No. 14.5)UPGRADATION OF UMARKHED TO TAKALI, TALUKA - UMARKHED, DISTRICT- YAVATMAL |
| 101 | Providing and fixing in position railing consisting of IS Rolled steel joist posts designation IS MB 100 (100 x 75) at 2.5m interval and three rows of 50 mm dia steel pipes ( light ) including fixing in position on bridge deck complete as per drawing and technical specification Clause 1208.2 (Item No. 13.8)UPGRADATION OF UMARKHED TO TAKALI, TALUKA - UMARKHED, DISTRICT- YAVATMAL |
| 102 | Expansion Joint with 25mm thick bituminous pad (Item No. 13.16 (II-A) P.No. 54)UPGRADATION OF UMARKHED TO TAKALI, TALUKA - UMARKHED, DISTRICT- YAVATMAL |
| 103 | Providing and laying of boulder apron laid in wire crates with 4 mm dia GI wire conforming to IS:280 and IS:4826 in 100mmx100mm mesh (wovendiagonally) including 10 percent extra for laps and joints laidwith stone boulders weighing not less than 25 kg each as per drawingand technical specifications Clause 1301(Item no 14.2 page no 54)UPGRADATION OF UMARKHED TO TAKALI, TALUKA - UMARKHED, DISTRICT- YAVATMAL |
AI Tender Summary
Tender Timeline
Jul 20, 2023
11:30 IST
Tender Published
Tender notice published.
CompletedJul 31, 2023
17:00 IST
Bid Submission Deadline
Online submission via eProcurement portal.
CompletedAug 01, 2023
Bid Opening Date
Technical bids will be opened and evaluated.
CompletedTender Documents
Download All (ZIP) ↓
Disclaimer
We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender