| 1 | Supply and erection in truely vertical position steel tubular swaged poles, type 410 SP-31 (9.00 meters) with 300 mm x 300 mm x 6 mm mild steel base plate continuously welded to poles, finial taper plug, bolts, nuts and screws all as specified including factory painted with two coats of black bituminous paint internally through out and externally for embedded portion and making 30 cms wide strips with yellow and black paint at alternatively upto 1.50 metre height and applying two coats of aluminium paint over a coat of red oxide primer on remaining exposed surface after erection including taking down of old unserviceable existing pole any size any type ,complete all as specified and directed by the Engr-in-Charge. |
| 2 | Earthing complete with galvanised mild steel earth plate electrode 60cmx60cmx6mm thick, burried directly in ground preferably in vertical position (Earth pit not less than 2.25 mtr below ground level) with top edge of the earth plate not less than 1.5 mtr below normal ground level, connected to galvanised iron strip 25×4 mmby means of bolts, nuts, check nuts and washers of galvanised iron including pit of PCC (1:2:4) type B-1, pre cast RCC cover slab of size 550x550x75mm, XPM reinforced not less than 1.60Kg/Sqm with suitable built in handle made from 12mm dia MS round bar, excavation and earth work in any type of soil, 20mm dia bore medium grade galvanised iron water tubing fixed with cast iron funnel and wire mesh at one end, 15mm bore light grade galvanised iron protection pipe for earth lead wire upto 5m length, charcol, common salt complete all as shown in electric plate No 3 of SSR 2009 Part I connected to equipment, testing on completion, complete all as specified and directed. |
| 3 | Excavation in trenches in hard/dense of soil not exc 1.5m wide and n.exc 1.5m in depth for electric poles stay foundation and under ground electric power cables and getting out, complete all as specified and directed. |
| 4 | Excavation in trenches in hard/dense of soil exc 1.5m wide and exc 1.5m in depth for electric poles stay foundation and under ground electric power cables and getting out, complete all as specified and directed. |
| 5 | Returning filling in, including spreading ,leveling ,watering and well ramming in layers not exc 25 cm complete all as specified. |
| 6 | Removing excavated soil to a distance not exceeding 50 mtr and deposting where directed at a level not exceeding 1.5 mtr above the starting point complete all as specified. |
| 7 | M&L for Brick covering with width equal to length of brick as mechanical protection to cables with well burnt sub class ‘B’ (old size) bricks laid dry flat, complete all as specified and directed. |
| 8 | Sand cushioning with fine sand to under ground cables in trenches/ducts in layers of 8 cm deep before laying the cable and 15 cm deep after laying and stretching the cable as specified in clause 19.75 of SSR Part-I, complete all as specified and directed by Engr-in-Charge. |
| 9 | Supply and lay in trenches, fixed to wall / pole/ tray etcUG cable XLPE insulated armouredheavy duty electric UG cable with aluminumconductor1100 volts grade of cross sectional area including taking down old cable, complete all as specified and directed by Engineer-in-Charge of following size all as specified and as directed. |
| 10 | 16 Sqmm 4 Core |
| 11 | 25 Sqmm 3.5 Core |
| 12 | 10 Sqmm 2 Core |
| 13 | XLPE insulated, armoured, heavy duty electric cables (heavy duty) with stranded aluminium conductor rating 1100 volts grade of size 50 Sqmm 3.5 core laid in trenches or passing through pipes/ducts or fixed to walls/polesincluding taking down old u/s cable, complete all as specified. Note:-(Earth work, brick protection and sand cushioning shall be measured and paid for separately). |
| 14 | All as per ser item No. 10.00 here in above but cross sectional area 70 sqmm 3.5 core |
| 15 | All as per ser item No. 10.00 here in above but cross sectional area 95 sqmm 3.5 core |
| 16 | All as per ser item No. 10.00 here in above but cross sectional area 120 sqmm 3.5 core |
| 17 | M & L for PCC 1:2:4 type B-1 (using 20 mm graded crushed stone aggregate) as in coping of pole around poleall as specified and as directed by Engineer-in-Charge. |
| 18 | M & L for PCC 1:4:8 type D-2 (using 40 mm graded crushed stone aggregate) as foundation of poleall as specified and as directed by Engineer-in-Charge. |
| 19 | M & L for PCC 1:3:6 type C-2 (using 40 mm graded crushed stone aggregate) as in foundation of pole around pole and for road filling all as specified and as directed by Engineer-in-Charge. |
| 20 | S&F in replacement of New generation energy saving and environmental friendly long life LED street light made up of pressure die cast aluminium housing with high power LED as lighting source with toughened glass top cover. TOP Opening seperate driver compartment with IP66 protection and impact resistance of IK07 with 10KV Built-in Surge Protection Device. of capacity 120 Watt including3 core 1.5 sqmm multistranded flexible copper conductor cable from connection junction box to light fittings deemed to be included in the quoted rate including taking down old unserviceable. Make : (Cat ENDURAPEARLMAGSL120WLED757PASYTOTGASTHO of Havells or equivalent cat part of make as specified in list of make here-in-after. |
| 21 | S&F in replacement ofEnergy saving, environment friendly, long life, exclusive innovative die-cast aluminium flood light with highly efficient IP- 66 LEDs as light source, suitable for highlighting architectural features or retail spaces of capacity150 Wattcompleted with connectionincluding3 core 1.5 sqmm multistranded flexible copper conductor cable from connection junction box to light fittings deemed to be included in the quoted rate and taking down old unserviceable. Make : (Cat JETAIRISFL150WLED757ARNBLTG of Havells or equivalent cat part of make as specified in list of make here-in-after. |
| 22 | Steel tubing galvanized (medium grade) 50 mm bore conforming to IS-1239 for passing cable under road/floor or fixing to poles for protection of underground cable complete with Flat iron 50x6mm clamps made to shape and 12mm dia bolts, nuts and washers for fixing where required. NOTE :- Excavation and earth work shall be measured and paid separatly |
| 23 | Steel tubing galvanized (medium grade) 40 mm bore conforming to IS-1239 for passing cable under road/floor or fixing to poles for protection of underground cable complete with Flat iron 50x6mm clamps made to shape and 12mm dia bolts, nuts and washers for fixing where required. NOTE :- Excavation and earth work shall be measured and paid separatly |
| 24 | M & L for pole painting 9.0 mtr long with two coat of aluminium paint after preparation of old painting surface by scrappining including marking of black and yellow strip not less than 30 cm width with sythethic enamelled paint from couping to upto height 1.5 mtr of pole alternative way including necessary `MES & Pole number to be wriiten in the circular yello batch on the pole all as specified and directed. |
| 25 | Supply and fixing in repairs earth continuity conductor or main earthing lead fixed to walls on batten or recess or chesses or buried in ground or fixed to poles or any other indicated situation for loop earthing with using 25 x 4 mm dia GI strip, complete all as specified and directed. |
| 26 | Supply and fix in replacement of stay assembly galvanised iron complete with accessories stay rod 20 mm dia, 180cm long with two nuts, stay bow 14mm dia and 38cm long with stay plate 300x300x6mm thick mild steel stay thimble and required length including binding to insulator stay bow and stay clamp galvanised iron stay strand wire 7/4mm dia, complete all as specified and shown in EP plate No 1 of SSR part-I, complete all as specified and directed.NOTE :- Excavation, earth work and concrete shall be measured and paid separatly |
| 27 | Supply and fix in replacement of Pin type, porcelain, vitreous, white, brown or green insulator including one galvanised mild steel spindle,two galvanised iron washers and one galvanised iron nut, 100mm height, 65mm dia for 1100 volts grade |
| 28 | Shackle Type, Porcelain, vitreous, white, brown or green insulator including galvanised mild steel straps, washers, insulator bolts, washers and nuts,1100 volt grade 75 x90 mm dia of bolt 12mm and section of straps 31x3mm, complete all as specifed and directed. |
| 29 | S&F in repair Aluminium conductor, steel reinforced of any size on LT Poles including straining,binding with insulators with Al/copper binding wire with insulators as in over head conductors, providing PVC Sleeves for jumper fixed as in repairs, complete all as specified and directed. |
| 30 | M&L in replacement of Galvanised steel wire 3.15 or 4mm dia,complete all as specified and directed. |
| 31 | M&L for painting of LT Panel Indoor/Outdoor typewith spray gun with two coats of synthetic enamel heat resistant grey paint including preparation of old painted surfaces/removing old faded/rust/ cemented material of surface of complete LT panel, complete all as directed. |
| 32 | M&L for replacement old rusted angle iron work and fixing/ fabrication of angle iron frame 40x40x5mm thick for LT Panel complete including fixing at site all as specified and directed by Egineer in charge. |
| 33 | M& L in repair to LT panel of any size/make incl cutting, welding of front panel, replacement of back cover and top covermade of CRCA steel sheet of size not less than 3.15mm thick, matching with existing inclhinges and locking devices complete all as directed by Engr-in-Charge. |
| 34 | S&F in replacement of aluminium bus bar PVC insulated in RED,yellow,Blue & Black colours of rating 400 Amps,complete all as specified and as directed. |
| 35 | Supply and fixing in replacementMCCB 100 Amps, three pole, 415 volt,50 Hz with breaking capacity 16 KA with adjustable type, complete all as specified and directed. |
| 36 | Supply and fixing in replacementMCCB 125 Amps, three pole, 415 volt,50 Hz with breaking capacity 16 KA with adjustable type, complete all as specified and directed. |
| 37 | Supply and fixing in replacementMCCB 160 Amps, three pole, 415 volt,50 Hz with breaking capacity 36 KA with adjustable type, complete all as specified and directed. |
| 38 | Supply and fixing in replacementMCCB 250 Amps, three pole, 415 volt,50 Hz with breaking capacity 36 KA with adjustable type, complete all as specified and directed. |
| 39 | Cross arm, bracings, supports, clamps and chequered steel back plates, angle iron equal size or any size fabricated from steel section including nuts, bolts, washers, welding bending cold or hot drilling holes for bolts in any shape or size for cover for cable duct any size and holdingoftwo pole strucures, GOD, street light GI bracket, junction boxes and fabrication of anti climbing devices, other works etc as indicated or directed and dulypainted with synthetic enamel aluminium/smooke grey paint over a coat of primerfixed \"as in repairs\",complete all as specified and directed . |
| 40 | M&L for loop type insulator Large size, with overall dimensions 90mmx140mm, clearance of hole 25.5mm suitable for stay assembly complete all as specified and directed. |
| 41 | M&L in replacement of1.1 KV LT (Heat shrinkable) cable jointing kit for 1.1 KV grade cable for straight through heat shrink type joint complete with jointing material and accessories suitable for 3.5 core XLPE armoured aluminium conductor cable of size up to 70 sq mm to 120 sqmm. |
| 42 | M&L in replacement of1.1 KV LT (Heat shrinkable) cable jointing kit for 1.1 KV grade cable for straight through heat shrink type joint complete with jointing material and accessories suitable for 3.5 core XLPE armoured aluminium conductor cable of size up to 25 sq mm to 50 sqmm. |
| 43 | House service bracket (hook type complete with 3.0m long G.I. pipe 40mm dia Med. grade, two nos 90 degree bends. M.S. hook and stay or guy |
| 44 | Supply and fix in replacment of1100 volts grade heavy duty cable PVC insulated aluminium conductor served with inner sheathing of PVC tape and overall PVC sheathed with stranded conductor 10 Sqmm twin core cable flat or circular complete all as specified. |
| 45 | Supply and fix in replacement of 1.5 Sqmm three core multi stranded copper conductor (FRLSH) cable PVC insulated unsheathed cable 1100 volt grade conformingto IS-694 complete all as specified and directed. |
| 46 | S&F in replacement of Junction feeder Panel alongwith busbar alumium busbar of 3 phase and neutral 400 Amps suitable for XLPE cable 95 Sqmm 3.5 Core to 120 Sqmm 3.5 core in and out, CPRI approved IP-54 duly painted with epoxy based powder coated paint, including base channel, of size 600x500x450 mmsuitable for out door type double door locking arrangement comprising ofits accessories, cable gland with hinged door, bus chamber with bolted double door etc dust & vermin proof construction attractive powder coated fixed/groutning on PCC foundation 45cm above ground level including all necessary excavation & earth work complete all as specified and directed. |
| 47 | Supply and Fix in replacemement of PVC separator four way suitable for LT over head lines all as specified and directed. |
| 48 | Supply, installation, commmissioning and testing CPRI approved LT Panel outdoor type size not less than 1.2X1.0X0.5 mtr ,double door (IP-54 Protection) floor mounted type CPRI type tested compartmentalised, made outoff 3.15 mm thick CRCA sheet duly powder coated complete with Copper bus bar (TPN) 600 Amps rating made up copper strip 50X5 mm duly drilled holes forconnection (TPN) and mounted on epoxy based insulators for 3 pahse 4 wire 415 volts 50 Hz, power supply system extended rotary handle Voltmeter, ammeter (Digital type)indicator lamps (RYB) internal wiring with suitable size of copper conductor PVC insulated and sheathed cable front and rear openable double door with locking arrangement, angle iron frame made out from 40x40x6mm angle iron frame and grouting with PCC,and foundation work and including the following items mentioned below:- |
| 49 | INCOMMER(i) MCCB 3 Phase, 4 Pole 400 Amps,36kA rupturing cap,ICs = 100%Icu with adjustble thermal and fixed magnetic setting 415 volts 50 HZ AC supply - 01 Nos (ii) Digital voltmeter 0 to 500 volt- 01 Set(iii) Digital ameter 0 to 400 amp- 01 Set(iv) Phase indicating lamp RYB with incating voltage in digital LED format ( set of three) - 01 SetOUTGOING(i) MCCB 3 Phase, 3 Pole 160 Amps,25 kA rupturing cap,ICs = 75%Icu with adjustble thermal and fixed magnetic setting 415 volts 50 HZ AC supply - 01 Nos (ii) MCCB 3 Phase, 3 Pole 100 Amps,25 kA rupturing cap,ICs = 75%Icu with adjustble thermal and fixed magnetic setting 415 volts 50 HZ AC supply - 03 Nos |
| 50 | Deduction to be made from BOQ for schedule of credit (Sch \"A\" Part - II) Amount of ? 36,283.00during AOCNote:- Tenderers shall not quote for this Schedule |