Military Engineer Services-MES has published Tender For Repair / Maintenance Of Dg Sets Amf Panels, Replacement Of Battery And Charger, Hot And Eot Cranes, Swimming Pool, Sewage Treatment Plant At Cod Chheoki Under Ge West Prayagraj.. Submission Date for this Tender is 09-08-2023. Dry Cell Batteries Tenders in prayagraj Uttar Pradesh. Bidders can get complete Tender details and download the document.




Tender Notice

38744505
Tender For Repair / Maintenance Of Dg Sets Amf Panels, Replacement Of Battery And Charger, Hot And Eot Cranes, Swimming Pool, Sewage Treatment Plant At Cod Chheoki Under Ge West Prayagraj.
Open Tender
Indian
Uttar Pradesh
prayagraj
09-08-2023

Tender Details

Repair / Maintenance Of Dg Sets Amf Panels, Replacement Of Battery And Charger, Hot And Eot Cranes, Swimming Pool, Sewage Treatment Plant At Cod Chheoki Under Ge West Prayagraj.

Key Value

Document Fees
INR 500 /-
EMD
INR 76000.0 /-
Tender Value
INR 38 Lakhs /-

BOQ Items

Name of Work: Repair/Maint of DG sets AMF panels, replacement of battery and charger, HOT and EOT cranes, Swimming pool, sewage treatment plant at COD Chheoki under GE (West) Prayagraj.
Sl. No. Item Description
1SECTION "A" (DG SET)
2M&L for periodicalservicing of diesel engine driven Gen set 3 phase 415 volts 50 c/s AC supply by cleaning thoroughly and replacing fuel filters, air filters, oil filtersdraining out engine oil etc. and replacing with new oil, tightening of all gaskets , connection of battery terminals, electric cable connections foundation bolts, coupling bolts etc includingtest running and tappet setting of alternator by checking and setting of voltage and frequency complete all as directed. Note: Engine oil, Fuel filters, Air filters, oil filtersreplaced will be measured and paid separately under respective item ofSch "A" . forfollowingcapacities of DG set
3500 KVA DG SET
4320 KVA DG SET
5225 KVA DG SET
663/62.5 KVA DG SET
7Supply only following spare parts for Ceiling / Exhaust fan : -
8Supply and fixing in replacement of maintenance free batterywith initiallychargedcapacity 180 AH , 12 Volt complete all as specified and as directed.
9Supply and fixing in replacement of maintenance free batterywith initiallychargedcapacity 150 AH , 12 Volt complete all as specified and as directed.
10Supply and fixing in replacement of maintenance free batterywith initiallychargedcapacity90 AH , 12 Volt complete all as specified and directed.
11Supply, fixing & testing in replacement of Radiator of 320 KVA DG Setwater cooled of kirloskar make with coppertubing including replacement of connected items such as inlet & outlet rubber hoses & all other connected items complete all as specified and directed.
12Supply, fixing & testing in replacement of Radiator of 62.5 /100 KVA DG Setwater cooled of kirloskar make with coppertubing including replacement of connected items such as inlet & outlet rubber hoses & all other connected items complete all as specified and directed.
13S&F in replacement of UNSV radiatorhose pipeset complete forDG set of 500 KVA capacity complete all as specified and directed.
14S&F in replacement of UNSV radiatorhose pipeset complete forDG set of 320 KVA capacity complete all as specified and directed.
15S&F in replacement of UNSV radiatorhose pipeset complete forDG set of 225 KVA capacity complete all as specified and directed.
16S&F in replacement of UNSV radiatorhose pipeset complete forDG set of 63/62.5 KVA capacity complete all as specified and directed.
17M & L in replacement of UNSV fan belts for DG setsof 500 KVA capacity complete all as specified and directed.
18M & L in replacement of UNSV fan belts for DG setsof 320 KVA capacity complete all as specified and directed.
19M & L in replacement of UNSV fan belts for DG setsof 225 KVA capacity complete all as specified and directed.
20M & L in replacement of UNSV fan belts for DG setsof 63/ 62.5 KVA capacity complete all as specified and directed.
21M&L in replacement of stranded copper conductor battery lead for 24 volts DC grade red for (+) ve terminal and black for (-) ve terminal fitted with battery terminal at one end & battery lug at other end complete length 1.5 mtr complete all as specified and directed.
22M&L for cleaning of radiator by cleaning agent/ Ready wash (make: Fleet guard/cool guard) including removal/ dismantling of radiator from engine transporting to work shop or cleaned at site, soldering / brazing, testing for any leakage , remounting to its original positionfor 500/ 320 KVA capacity DG Set complete all as specified and directed.
23M&L for cleaning of radiator by cleaning agent/Ready wash (make: fleet guard/cool guard) including removal/ dismantling of radiator from engine transporting to work shop or cleaned at site , soldering / brazing, testing for any leakage , remounting to its original position for 200/ 250 capacity DG Set complete all as specified and directed.
24M&L for cleaning of radiator by cleaning agent/Ready wash (make: Fleet guard/Cool guard) including removal/ dismantling of radiator from engine transporting to work shop or cleaned at site , soldering / brazing, testing for any leakage , remounting to its original position for 63/ 62.5 KVA capacity DG Set complete all as specified and directed.
25M&L for replacement of set of hose clips for 320 KVA DG sets complete all as specified and directed.
26M&L for replacement of set of hose clips for 225 KVA DG sets complete all as specified and directed.
27M&L for replacement of set of hose clips for 63/62.5 KVA DG sets complete all as specified and directed.
28M&L for coolant radicool SFO premixfor DG set complete all as specified and directed.
29M&L to drain out the old used engine oil from sump of DG sets& cleaning & refilling with new engine oil 15 W 40 up to required level including top up complete all as specified and directed.
30M&L for replacement of defective self starter assembly by new self starter assembly 12/24 volts complete all as specified and directed. Make: lucas / Bosch
31M&L for replacement of defective alternator assembly by new alternator assembly 12/24 volts complete all as specified and directed. Make: lucas / Bosch
32M&L in for replacement of PCB card Procom R E L-7-1.0 for 225/63.5 KVAAMF pannel complete all as specified and directed.
33M&L in for replacement coil Relay-24 volts,5 Amp 240 volt AC 5Amp 30 volts DC model HJQ 22 F –VZ make YOI/ Siemens for 160/100KVA AMF panel complete all as specified and directed.
34M&L in for replacement coil Relay-24 volts,5 Amp 240 volt AC 5Amp 30 volts DC model HJQ 22 F –VZ make YOI/ Siemens for 62.5/40KVA AMF panel complete all as specified and directed.
35M&L in for replacement of timer switch0 to 80 seconds MakeSiemens for160/100KVA AMF panel complete all as specified and directed.
36M&L for servicing of DG set 320 KVA AMF panel, setting of time delay switch ,tightening of all electrical incoming & outgoingconnections including replacement of cable lugs& adjustment of solenoid switches & relays complete all as specified & directed.
37M&L for servicing of DG set 225 KVA AMF panel, setting of time delay switch ,tightening of all electrical incoming & outgoingconnections including replacement of cable lugs & adjustment of solenoid switches & relays complete all as specified & directed.
38M&L for servicing of DG set 62.5/40 KVA AMF panel, setting of time delay switch ,tightening of all electrical incoming & outgoingconnections including replacement of cable lugs & adjustment of solenoid switches & relays complete all as specified & directed.
39Supply, installation, commissioning & testing of electronic battery charging setsuitable for charging batteries12/24 V, 10/12Amps complete with meter equipments, selector switch with required size of copper wire up to required lengthand 1No. 3 pin plug top 5 Amps including disconnecting & taking out of existing battery charging set complete all as specified.
40M & L for painting of Generating set of capacity225KVA to 320KVA complete in existing colour with twocoat of synthetic enamelled paint byspray machineafter preparation of surfaces complete all as specified and as directed.
41M & L for painting of Generating set of capacity7.5KVA to 62.5KVA complete in existing colour with twocoat of synthetic enamelled paint with spray machine after preparation of surfaces complete all as specified and as directed.
42S & F in repair on load four pole change over with advance Neutral On load change over switch I-O-II ,current Rating 100 Amps, 415 Volts complete all as specified and directed.
43S & F in repair On load four pole change over with advance Neutral On load change over switch I-O-II ,Current Rating 200 Amps,415 Volts complete all as specified and directed.
44S & F in repair On load four pole change over with advance Neutral On load change over switch I-O-II ,Current Rating 400 Amps, 415 Volts complete all as specified and directed.
45Supply only Diesel Filter suitable for 62.5 KVA to 100 KVA DG set complete all as specified and directed.
46Supply only Diesel Filter suitable for 200KVA to 320KVA DG set complete all as specified and directed.
47Supply only Lube Oil filter suitable for 62.5 KVA to 100 KVA DG set complete all as specified and directed.
48Supply only Lube Oil Filter suitable for 200KVA to 320KVA DG set complete all as specified and directed.
49Supply only Airfilter suitable for 62.5 KVA to 100 KVA DG set complete all as specified and directed.
50Supply only Air Filter suitable for 200 KVA to 320KVA DG set complete all as specified and directed.
51Supply & fixing of spare parts & accessories of original make for repair of DG set of capacity 62.5 KVA/ 100 KVA/ 200 KVA/ 320 KVA all as directed by Engr-in-Charge. Note :- (i) All spares & accessories shall be fixed in the DG set only after prior inspection & approval of Engineer-in-Charge for which these shall be produced by the contractor at store yard of AGE E/M New Cant. (ii) Spare parts shall be measured & paid under respective items.
52Kit Fuel filter
53KitLube oil filter
54Kit bypass filter
55Kit Air cleaner
56Air filter
57Upper Gasket set (Cylinder head)
58Valve exhaust
59Valve inlet
60Valve seat Exhaust
61Valve seat Inlet
62Guide valve
63Collect Valve
64Spring valve
65Kit turbo charging
66Collar thrust
67Kit injector
68Kit Piston and ring set
69Kit Cylinder liner
70Kit Sump Gasket
71Gear pump assembly (Fuel pump FIP)
72Weight & carrier
73Barrel sleeve
74Gasket Set
75Suction filter
76Governor Pressure valve (Hydraulic Governor)
77Gear assembly
78Ball bearing
79Head gasket
80Nozzle
81Block
82Liner
83Battery terminal
84Packing Kit
85Crank
86Main bearing
87CR bearing
88Came bush
89Connecting Rod
90Rod balancing
91Bush
92Third washer
93Valve seal
94Governor controller
95Dismantling ofDG Set Alternator of capacity 65 to 225 KVA carefully and carry to authorised workshop for repair and re-fixing the same in its original position after repair and testing the same up to satisfaction of AGE E/M complete all as specified & directed. Note:- Necessary winding of alternator & repairing of armature shaft and required parts to be replaced shall be paid as supply only under respective items here-in-after.
96Cutting out old burnt winding of alternator, cleaning the slot of stator and rewinding the same with super enamelled copper winding wire of appropriate gauge complete with all insulating materials, nomex paper, cotton tape, glass sleeve, soldering rod, Grease etc complete all as specified & directed.
97Repairing ofarmature shaft both side by depositing metal on it, grinding & polishing to make appropriate size of the shaft complete all as specified & directed.
98Supply only ball bearing at DE (Driven End) side of No.6310 complete all as specified & directed.
99Supply only rectifier diode complete all as specified & directed.
100Supply only AVR (Automatic Voltage Regulator) complete all as specified & directed.
101Supply only connection plate of suitable size complete all as specified & directed.
102Dismantling ofDG Set Alternator of capacity 320 / 500 KVA carefully and carry to authorised workshop for repair and re-fixing the same in its original position after repair and testing the same up to satisfaction of AGE E/M complete all as specified & directed. Note:- Necessary winding of alternator & repairing of armature shaft and required parts to be replaced shall be paid as supply only under respective items here-in-after.
103Cutting out old burnt winding of alternator, cleaning the slot of stator and rewinding the same with super enamelled copper winding wire of appropriate gauge complete with all insulating materials, nomex paper, cotton tape, glass sleeve, soldering rod, Grease etc complete all as specified & directed.
104Repairing ofarmature shaft both side by depositing metal on it, grinding & polishing to make appropriate size of the shaft complete all as specified & directed.
105Supply only ball bearing at DE (Driven End) side of No.6310 /6311/6312/6314 complete all as specified & directed.
106Supply only rectifier diode complete all as specified & directed.
107Supply only AVR (Automatic Voltage Regulator) complete all as specified & directed.
108Supply only connection plate of suitable size complete all as specified & directed.
109Dismantling ofDG Set Alternator of capacity 62.5 KVA carefully and carry to authorised workshop for repair and re-fixing the same in its original position after repair and testing the same up to satisfaction of AGE E/M complete all as specified & directed. Note:- Necessary winding of alternator & repairing of armature shaft and required parts to be replaced shall be paid as supply only under respective items here-in-after.
110Cutting out old burnt winding of alternator, cleaning the slot of stator and rewinding the same with super enamelled copper winding wire of appropriate gauge complete with all insulating materials, nomex paper, cotton tape, glass sleeve, soldering rod, Grease etc complete all as specified & directed.
111Repairing ofarmature shaft both side by depositing metal on it, grinding & polishing to make appropriate size of the shaft complete all as specified & directed.
112Supply only ball bearing at DE (Driven End) side of No.6310 /6311/6312/6314 complete all as specified & directed.
113Supply only rectifier diode complete all as specified & directed.
114Supply only AVR (Automatic Voltage Regulator) complete all as specified & directed.
115Supply only connection plate of suitable size complete all as specified & directed.
116S & F in repair MCCB 100 Amps, 415 Volts, 4 Pole, breaking capacity 16/25 KA, ISI marked, fix type complete all as specified & directed.
117S & F in repair MCCB 200 Amps, 415 Volts, 4 Pole, breaking capacity 25KA, ISI Marked, Fix / Adjustable type complete all as specified & directed.
118M&L for repair/overhauling of existing starter panel board of any size/type including cleaning with compressed air tightening of all electric connections to switches including repair/replacement of existing MCB/ switch fuse disconnect or units each of anyratingincluding testing complete with fixing of door (front & backside) with proper fixing & locking arrangement replacement of worn-out lugs, nut, bolts, internal wiring with suitable size (minimum 1.5 Sqmm) of PVC copper conductor wire and lugs, proper connection to main earth lead, to be provided/replaced as required at cable entries, fixing of door front & back with copper locking arrangement as required as site and painting with spray machine with super enamelled paint light grey paint in outer/ inner side of panel after cleaningand preparing surface including sign writing complete all as specified and directed. Note : Defective parts to be replaced& shall be measured and paid separately as supply only under respective item.
119Supply only contractor TF 34 make Siemens or equivalent approved
120Supply only contactor TF 30 Make Siemens or equivalents approved
121Supply only Contactor TF 31 Make Siemens or equivalents approved
122Supply only PVC Connector
123Supply only over Load Relay capacity 20-30 amp Make Siemens or equivalents approved
124Supply only over Load Relay capacity 10-20 Make Siemens or equivalents approved
125Supply only MCB TPN 63amps "C" series 415 Volt
126Supply only MCB TPN 32amps "C" series 415 Volt
127S & F in replacement of exhaust silencer complete with muffler of 100 KVA/62.5 KVA DG set complete & connect engine and DG silencer to drive away hot gases generated during operation of DG to atmosphere through silencer complete all as specified & directed.
128Dismantling and taking out the self starter,12 Volt DCfitted in 15to 62.5 KVA 3 phase 50 HZof DG setsand strip opening of self starter 12 Volt DC for carrying out repair/ servicing /overhauling mechanically ,cleaning, oiling/greasing/varnishing, fixing of serviceable parts in position, removing & replacement of defective / unserviceable parts with new parts, complete and re-assembling ofself starter 12 Volt DC after repair/ servicing /overhaulingand fixing the same in position and testing complete all as specified and directed .Notes :- (i)Repairs/servicing / reassembling and testing of Self starter 12 Volt DC shall be carried out through a authorised service centre .(ii) The quoted rates of the contractor includes for fixing the serviceable parts in position and replacement of unserviceable parts with new parts.The new replaced parts shall bemeasured and paid for separately under appropriate item of Sch `A’ as `supply only ‘ but quoted rates are inclusive of replacement of small/minor parts such as nuts, bolts, washers, shim, small springs, screws/gaskets/ packing /studs etc. (iii) The quoted rates of contractor are deemed to be included cost of transportation toauthorized service centre & return back to site. (iv) Contractor shall have no claim on account of variation of quantities of any item or non execution of any item.
129Supply only solenoid switch suitable for self starter, 12 Volt DC
130Supply only commutator suitable for self starter, 12 Volt DC
131Supply only carbon brush suitable for self starter, 12 Volt DC
132Supply only field coils suitable for self starter, 12 Volt DC
133Supply only bendix pinion assembly suitable for self starter, 12 Volt DC
134Supply only Bush suitable for self starter, 12 Volt DC
135Supply & fixing ofmicro processer start/stop control PCB panel for 250/100/62.5 KVA DG set including taking out unserviceable relay complete with following parameters Make: Kirlosker/ Greaves /Cummins (a)Individual phase current (Amps) (b) Phase voltages (V) (c ) Generator output frequency (Hz) (d) Engine water temperature (Deg.C) (e) Lube oil pressure (kpa) (f) Working hours (g) Push button (Starter) & (stop) (h) LED indications for main function
136Material & labour for replacement of unserviceable interconnection wiring and its interlocking system in AMF electric control panel for DG setwith using and including PVC insulated and unsheathed stranded copper conductor cable, single core, minimum 1.5 Sqmm size or as required 1100 Volts grade cable for making functional controls of the DG set, auxiliary contactor, push buttons, indicator, amps meter, volt meter complete as required at site for functioning of DG set in auto and manual mode, checking AC/DC circuits and removing & replacement of defective / unserviceable parts with new parts,complete all as specified and directed . Notes:(i) The complete panel shall be checked and tested on full load after necessary repairs and replacement of unserviceable wiring. for its smooth functioning and proper interlocking including shut down on high water temperature and low Oil pressure. (ii)All control wires shall be properly bunched, tied, ferruled for proper identification and crimped with adequate size of copper lugs. the cost of same are deemed to include under these items.(iii) The quoted rates of the contractor includes for fixing the serviceable parts in position and replacement of unserviceable parts with new parts.The new replaced parts shall bemeasured and paid separately under appropriate item of Sch `A’ as `supply only ‘ but quoted rates are inclusive of replacement of small/minor parts such as nuts, bolts, washers, shim, small springs, screws/gaskets/ packing /studs etc.(iv) Contractor shall have no claim on account of variation of quantities of any item or non execution of any item.
137Supply only electronic timer, on delay type, dual range, suitable of 220 Volts/ 24 Volts, 2NO+2NC, 50 Hz, AC supply/ DC supply, for 0-60 seconds.
138Supply only Power contactor 3 polewith 2NO + 2NC auxiliary contacts, coil voltage 220 volts, AC 3 rating 300/325/330 Amps. Complete all as specified and directed .
139Supply only Power contactor 3 polewith 2NO + 2NC auxiliary contacts, coil voltage 220 volts, AC 3 rating 400 Amps. Complete all as specified and directed .
140Supply only Power Contactor No volt coil suitable for 400Amp Contactor
141Supply only Power Contactor No volt coil suitable for 300/325/330 Amp Contactor
142Supply only Auxiliary relay 8 pin, 24 Volts ,DC , 2 change over.
143Supply only Auxiliary relay 8 pin, 220 Volts , AC , 2 change over.
144Supply only Bimetal under volt / over volt relay suitable for 3 phase, 3 wire with 2 NO+2NC auxiliary contacts
145Supply only Engine starting relay with sequence timer & Master timer suitable for 12 / 24 Volts DC supply.
146Supply only Selector switch 3 way for auto manual operation .
147Supply only Selector switch 4 way for operation of volt meters & Ammeter.
148Supply only Indicating lamps LEDtype with holderfor 12 / 24 volts DC supply
149Supply only Digital electronic ammeter double ratio with 5 Amps secondary current of any range, flush pattern sequence type size 96 mm X 96 mm suitable for existing CT ratiofor maintaining on 415 Volts built in selector switch
150Supply only Digital electronic volt meter 0-50 V range suitable for 12 / 24 volt DC supply panel flush pattern square type size 96mm X 96mm
151Supply only Digital electronic volt meter 0-500 V range suitable for 415 Volts panel flush pattern square type size 96mm X 96mm
152Supply only Digital electronic Frequency meter 40-99.99 HZ built in selector switch, suitable for 415 Volts panel flush pattern square type size 96mm X 96mm
153Supply only HRC fuse DIN type with base for AC circuit 415 volts having rating of 400 Amps .
154M & L for cleaning of MS fuel tank of DG sets of 100 to 300 ltr capacity by collecting the fuel in cleaned barrels and removing sludge deposited/accumulated inside the tank of and disposal of sludge at a distance not exceeding 100 metre and cleaning the tank with kerosene oil including replacement of fuel tank strainer and unserviceable fuel gauge with new PVC fuel level indicator fixed with clips to the tank and marking levels for every 10 litre by marking and numbering on the side of fuel tank with synthetic enamelled paint and refilling the collected fuel after filtration complete all as specified and directed.
155S & F in replacement of exhaust silencer complete with muffler of 320 KVA DG set complete & connect engine and DG silencer to drive away hot gases generated during operation of DG to atmosphere through silencer complete all as specified & directed.
156S&F in replacement ofAmp meter, digital type Make: AE/Rishabh
157S&F in replacement of Volt meter , digital type Make: AE/ Rishabh
158S&F in replacement of AC spare coil 240/415V for contactor 50 to 100 Amps capacity complete Make: Havells/ L&T/ HPL
159S&F in replacement of AC spare coil 240/415V for contactor 125 to 185 Amps capacity complete Make: Havells /L&T /HPL
160S & F in replacement of SMF battery 12 volt 17 AHcomplete as directed.
161S & F in replacement of standard projection head push button with indicatorand selector actuator 22.5 mm dia with contact block forHC61A & HC61B2completeMake: L & T Cat part No. HF45CO
162S&F inreplacementPower contractor MCX 44 for AMF Panel as specified and directed .Make L&T
163S&F inreplacementPower contractor MCX 40 for AMF Panel as specified and directed .Make L&T
164S&F under voltage relay 415 volts for AMF panel as specified and directed .
165Section "B" (Cranes)
166S&F in replacement of DOL starter three phase,415 volt suitable for upto 5HP motor as specified and directed
167S&F in replacement of flame proof suspension type pendent / hanging controlling unit with flame proof star/ stop push buttons with indicator lamp and emergency control remote , lifting hock for UP and DOWN , long travel motion ,cross travel and connoting to controlling micro speed panel suitable for safe and smooth operating system of EOT crane of 2 Tons capacity including making cable connection and testing complete all as specified and directed. Make BCH or equivalent as approved by Engr-in-charge.
168S&F in replacement of flame proof suspension type pendent / hanging controlling unit with flame proof start / stop push buttons with indicator lamp and emergency control remote , lifting hock for UP and DOWN, long travel motion ,cross travel and connoting to controlling micro speed panel suitable for safe and smooth operating system of EOT crane of 10 Tonsto 20 tons capacity including making cable connection and testing complete all as specified and directed. Make BCH or equivalent as approved by Engr-in-charge.
169S&F MCCB fixed thermal and fixed magnetic setting type of capacity 400 amps , 4 pole of breaking capacityicu 36kA,415 volts AC 50Hz as per including fitted with suitable sixe of aluminium lugs complete and taking down of existing MCCBs all as specified and directed Make- Havells , L&T , ABB or equivalent as approved by Engr-in-charge.
170S&F MCCB fixed thermal and fixed magnetic setting type of capacity 315 amps , 4 pole of breaking capacityicu 36kA,415 volts AC 50Hz as per including fitted with suitable sixe of aluminium lugs complete and taking down of existing MCCBs all as specified and directed Make- Havells , L&T , ABB or equivalent as approved by Engr-in-charge.
171S&F main switch DP switch HRC type of capacity 400 amps , 4 pole in metal 415 volts AC 50Hz as per including fitted with suitable sixe of aluminium lugs complete and taking down of existing Main switch all as specified and directed Make- Havells , L&T , ABB or equivalent as approved by Engr-in-charge.
172S&F in replacement of unserviceable main gear box oil seal packing ,gear box ball bearing etc or other defected connecting parts as required at site sample /type and making it oil leak proof and sound less proof complete and including testing on load of 2 ton EOT crane complete all as specified and directed .
173S&F in replacement of unserviceable main gear box oil seal packing, gear box ball bearing etc or other defected connecting parts as required at site sample /type and making it oil lask proof and sound less proof complete and including testing on load of10 ton to 20 ton EOT crane complete all as specified and directed .
174M&L for servicing of over head crane complete including checking / tightening of nuts , bolts and breakers complete system, adjusting of breaks motions and VFD adjustment setting as per load testing run of flame proof / non flame proof / normal type EOT/ HOT cranes with having single or double girder type and providing greasing &oiling of travelling / moving parts of cranes with connecting motor girder parts for movement of cranes hoist / long /cross travelling and including maintained the controlling of speed /creeping micro speed of motors with minor maintenance/repair the electrically operated main control panel wire with connecting control wiringsystem consisting of main switch ,step down transformer, contractor ,HRC fuse , VFD, PLR ,control pendent , wire rope with break drumunit , gear box unit ,oil levels , motor bed / foot, electrical control cable , motor terminal, end cable carriage trolley , motor shaft , bush flange bearing with lathe work , chain pulley block , racketclutch ,gear block , chain wheel ,chain etc and including locating the defected fault and rectification of the fault and rectification of oil leakage etc any type and size and replacement of defected nut, bolts& washer and making it sound less proof and after trails testing runcomplete all as specified in present of Engr-in- charge Note:- (i) Servicing , adjusting etc of breaks motions and testing run work will be carried out by well qualified technician having good experience in the about repairing field of EOT cranes. (ii) It is personally responsibly / liability of contractor for smoothfunction of cranes for 09 month after the handing /taking over of all site without any extra cost to department(iii) Contractor shall be immediately depute suitable nos of experienced technician to attend the complaints on required basis for found unserviceable of crane with in the effected time after launching of complaints or all as specified and directed by Engr-in-charge
175EOT crane of capacity 20 tons
176EOT crane of capacity 2 tons
177EOT crane of capacity 10 tons
178S &F Limit switch for crane from 10 tons to 20 ton
179S&F Crane operatingPush button Remote 2 tons to 20 tons
180S&F in replacement of magnetic brake 0.5HP 415V alongwith connecting fixing accessories as per existing sample / model suitable for break system of 2 Tons EOT cranes complete specified and directed.
181S&F in replacement of hydraulic brake 1HP 415V alongwith connecting fixing accessories as per existing sample / model suitable for break system of 10 Tons to 20 tons EOT cranes complete specified and directed.
182M&L for taking down of unserviceable motor from Over HeadCranes and including transporting and rewinding electric motor of capacity upto 2 HP ,3 phase 415 volts ,with supper enamelled copper conductor wire as per existing size/gauge including making vanishing drying and connecting fixing accessories etc including refixing on same position and testing on load complete all as specified and directed.
183M&L for taking down of unserviceable motor from Over HeadCranes and including transporting and rewinding electric motor of capacity upto 5 HP ,3 phase 415 volts ,with supper enamelled copper conductor wire as per existing size/gauge including making vanishing drying and connecting fixing accessories etc including refixing on same position and testing on load complete all as specified and directed.
184M&L for Rail repair of cranes 10 to 20 tons making smooth for functional , cleaning dust, welding works complete all as specified and directed.
185S&F in replacement of FRLS PVC insulated electric cable with multi stranded copper conductor cable with having of single 4 core of 10 Sqmm ,1100 volts grade and making cable connection complete all as specified and directed.
186S&F in replacement of FRLS PVC insulated electric cable with multi stranded copper conductor cable with having of single 4 core of 6 Sqmm ,1100 volts grade and making cable connection complete all as specified and directed.
187S&F in replacement of FRLS PVC insulated electric cable with multi stranded copper conductor wire with having of single 2 core of 2.5 Sqmm ,1100 volts grade and making cable connection complete all as specified and directed.
188Supply and Fixing inreplacementPower contractor MNX -110for EOT Crane Make:- L&T
189Supply and Fixing inreplacementPower contractor MNX 95for EOT Crane Make :- L&T
190Supply and Fixing inreplacementPower contractor MNX 32for EOT Crane Make :- L&T
191Supply and Fixing inreplacementPower contractor MNX 22for EOT Crane Make :-L&T
192Supply and Fixing inreplacementPower contractor MNX 18for EOT Crane Make :-L&T
193Supply and fixing in replacement over relay 415 Volts
194Supply and fixing in replacement bearing VC 210 for HOT Crane Make NBC
195Supply and fixing in replacement bearing VC 205 for HOT Crane Make NBC
196Supply and fixing in replacement Electric Hose10/20 Ton Capacity 415 Volts
197Supply and fixing in replacement AC drive ( inventer ) 10/20 HP415 Volts
198Supply and fixing in replacement PT coil 415 Volt
199Section "C" (Swimming Pool)
200Quarterly Periodical, preventive and comprehensive maintenance of suction sweeper machine with motor and trolleyby dis-assembly, repairing, overhauling, servicing, connection & testing complete of following equipments all as specified & directed.
201Quarterly Periodical, preventive and comprehensive maintenance of Induction motor 20 HP capacity including pumpby dis-assembly, repairing, overhauling, servicing, connection & testing complete all as specified & directed.
202M & L foropening the filter tank of swimming pool plant and taking out old sand and carbon media including cleaning/ washing complete all as directed. NOTE: Sand and carbon media measured and paid separately in relevant item.
203Supply, transporting & filling of TTCA 95% granules in 45 Kg container complete all as directed.
204Supply, transporting & filling of copper sulphate granules in 25 Kg bag complete all as directed.
205Testing of Chemical & Bacteriological quality of inlet (Raw Water) and out let (treated water) sewage water offollowing parameters:(i)    PH value (ii)   Suspended solids (iii)    Total dissolved solids (iv)   C.O.D (v)    BOD (vi)    Oil & Grease
206S&F 150mm bore sluice valve, heavy duty both ends flanged class PN-I with high tensile brass spindle cast iron head operated wheel and cap top, nuts and bolts, washers including 3mm thick rubber gasket joint including taking down old unserviceable valve complete all as specified and directed.
207S&F 100mm bore sluice valve, heavy duty both ends flanged class PN-I with high tensile brass spindle cast iron head operated wheel and cap top, nuts and bolts, washers including 3mm thick rubber gasket joint including taking down old unserviceable valve complete all as specified and directed.
208S&F in replacement horizontal type Submersible cable 4 sqmm 3 core 230 Volts including connection lugs with pumps complete all as specified and directed.
209M&L for pea Gravel in filtration plant of swimming pool and change with old gravel as complete all as specified and directed
210Supply, installation, testing and commissioning in replacement ofindoor type cubical panel board suitable for 3 phase, 4 wire, 415V, 50 Hz and CPRI approved manufacturerfactory fabricated with CRCA sheet not less than 3.15 mm thick having modern fabrication process powder coating in approved shade provided with suitable gasket to make it dust and vermin proof and general constructions conforming to IS : 8623/93. The LT panel shall be front and back open able andduly compartmentalized for each control gears. The panel should have suitable size of aluminium Bus -bar three phase 4 wire system having current carrying capacity 400 Amps of the incomer MCCB. The panel should have the following incoming and outgoing controls duly fixed with the panel by means of suitable link plates complete all as specified and as directed by Engineer -in-charge. Note: PCC platform of suitable size for mounting the LT Panel is deemed to be included in the quoted rate. (i) MCCB 4, pole 35 KA with adjustable thermal setting, 415V, 160 Amp- 01 No. (ii) MCCB 4, pole 35 KA with adjustable thermal setting, 415V, 100 Amp- 01 No (iii)Star delta starter comprising suitable size of 3 pole contactors for 10 HP submersible pump with thermal over load relay complete - 01 No (iv) Motor protection relay for single phase, over load, over voltage (v)Digital Volt meter 0-500 volts (vi)Ammeter 0-500 amps with suitable size of Cts (vii) All connections to be done through suitable size PVC insulated copper cables (viii) LED RYB indicator - 01 Set (ix)MCCB" TP 32 Amps 16 KA - 02 No (x)MCB SPN 32 Amps 10 KA - 02 No (xi) Single phase preventer - 01 No
211Section "D" (Sewage Pump)
212Taking out/dismantling non clog sewage pump unit 20 HP capacity and overhauling, oiling & greasing including replacement of impeller, bush &oil sealand worn out bolt &washer, grinding & polishing if required complete all as specified & directed. Note: (i) Required spare parts like impeller, bush &oil seal will be measured and paid separately as supply only under respective item here-in-after. (ii) Quoted rates are inclusive of replacement of small / minor parts such as nuts, bolts, washers, shim, small springs, screws/gaskets/ packing /studs etc.
213Supply only Non clogging heavy impeller for 20HP
214Supply only bush for 20HP
215Supply only oil seal for 20HP
216Repair/Overhauling / unserviceable non clog sewage pump including electric motor 20 HP, 3 phase, 415 Volts, disconnecting the electric connection and dismantling the motor. Cutting the burnt winding and cleaning the slots with non greasy materials and rewinding with PVC insulated copper wire as per existing size with insulating material, complete reassembling the motor, repair and overhauling of pumps, replacement of bearing, remetalling of gun metal impeller, grinding, polishing, greasing complete all as directed and testing complete to entire satisfaction of Engr-in-charge
Disclaimer :