Execution Of Different Works Related To Chhit Bara Laukuthi Pipe Water Supply Scheme Under Jal Jeevan Mission, Coochbehar-West Bengal

Public Health Engineering Department-PHED has published Execution Of Different Works Related To Chhit Bara Laukuthi Pipe Water Supply Scheme Under Jal Jeevan Mission. Submission Date for this Tender is 09-08-2023. Water Pipe Line Tenders in Coochbehar West Bengal. Bidders can get complete Tender details and download the document.




Tender Notice

38736723
Execution Of Different Works Related To Chhit Bara Laukuthi Pipe Water Supply Scheme Under Jal Jeevan Mission
Open Tender
Indian
West Bengal
Coochbehar
09-08-2023

Tender Details

Execution Of Different Works Related To Chhit Bara Laukuthi Pipe Water Supply Scheme Under Jal Jeevan Mission- 1 Tubewelldrilling By Reverse Rotary Method Of Drilling Using 9 7 / 8” Dia.Bit For Pilot Bore Follwed By Subsequently Reaming Using 12 1 / 4” Dia. , 15 Dia. And 17.5 Dia. Rock Roller Bits / Drag Bits In Consolidated, Semi Consolidated And Soft Formation Up To Required Depth Including Casing Boring And Casing Lowering As Required Including Cost Of Fuels And Lubricants Etc. As Required For Drilling. 2 Rate For Drilling By 17.5 Dia. Bita ) From 6 Mtr. To 60 Mtr. 3 60 Mtr. To 90 Mtr. 4 90 Mtr. To 120 Mtr. 5 120 Mtr. To 144 Mtr. 6 Electro-Logging Charge. 7 Supply And Delivery Of Washed Gravels Size Ranging From 1.80 Mm To 4.74 Mm. Conforming To Is 4097 : 1967. 8 Site Preparation, Temporary Latrine, Placement & Levelling Of Rig Machine, Mast Hoisting And Casing Drilling ( Upto 6 Mtr. ) Placement Of Casing With All Allied Works Necessary To Commence Drilling Woks And Wind Up Of All Machineries After Completion Of Drilling. 9 Transportation Cost Of Drilling Equipment And Accessories Rig Machine Etc. Including Cost Of Fuel, Lubricant & Loading Unloading The Materials From Store / Stack Yard / Suppliers Godown And Unloading / Stacking The Same At Site. ( Upto 60.0 Km Distance ) 10 Lowering The Tube Well Assembly ( Upvc Casing Pipe , Well Pipe, Strainer Along With Upvc Accessories ) Vertically In A Position With Proper Lowering Arrangement By Applying Necessary Jointing Compound Including Labour Cost For Subsequent Gravel Packing And Machine Operation Cost Etc 11 Cost Of Consumables For Drilling Rigs And Machineries. 12 Supply And Delivery Of Upvc Pipe ( Cd ) Conforming To Is 12818:2010. ( Cipet Certified ) A ) 250 Mm Dia. 13 B ) 200 Mm Dia. 14 Supply And Delivery Of Upvc Deep Well Screen ( Rds ) Pipes With Ribs Conforming To Is 12818:2010 . ( Cipet Certified ) A ) 200 Mm Dia. 15 Supply And Delivery Of Upvc Reducera ) 250Mm X 200 Mm Dia. 16 Supply And Delivery Of Upvc Capa ) 200 Mm Dia. 17 B ) 250 Mm Dia. 18 Supply And Delivery Of M.S. Housing Clamp 250 Mm Dia. 19 Supply And Delivery Of M.S .Centre Guide ( Special Type ) . 20 Development ( Min. 8 Hr. Continuous ) Of Tube Well By Using Suitable Air Compressor ( Min. Capacity: 600Cfm & Operating Pressure 14 Bar ) Followed By Yield Testing With Bht Pump ( Head :45 To 50Mtr., Discharge :1100 To 1000 Lpm And 25 Bhp Engine ) All Complete Including To & Fro Transportation Cost And Cost Of Fuels, Lubricants & Labour Etc. 21 Water Sample Collection And Chemical Test Including Arsenic Test. 22 Protective Sealing The Annular Space Between Tube Well Pipes & The Bore By Bentonite Clay Balls / Cement Slurry Above The Shrouded Gravels ( 3 M. Height ) . 23 Packing The Annular Space Between The Outsides Of The Housing Pipe & The Bore With Puddle Clay Balls Of Approved Size As Per Direction Of E.I.C. Including Cost Of All Materials, Labour Complete. 24 Supply And Delivery Of Bentonite Powder Conforming To Is 6186 :1986. 25 Labour For Making Arrangement For Showing Verticality Test Including The Cost For Hire Charges Of Tools And Plants, Scafolding, Labour Etc. All Complete 26 Tubewelldrilling By Reverse Rotary Method Of Drilling Using 9 7 / 8” Dia.Bit For Pilot Bore Follwed By Subsequently Reaming Using 12 1 / 4” Dia. , 15 Dia. And 17.5 Dia. Rock Roller Bits / Drag Bits In Consolidated, Semi Consolidated And Soft Formation Up To Required Depth Including Casing Boring And Casing Lowering As Required Including Cost Of Fuels And Lubricants Etc. As Required For Drilling. 27 Rate For Drilling By 17.5 Dia. Bita ) From 6 Mtr. To 60 Mtr. 28 60 Mtr. To 90 Mtr. 29 90 Mtr. To 120 Mtr. 30 120 Mtr. To 144 Mtr. 31 Electro-Logging Charge. 32 Supply And Delivery Of Washed Gravels Size Ranging From 1.80 Mm To 4.74 Mm. Conforming To Is 4097 : 1967. 33 Site Preparation, Temporary Latrine, Placement & Levelling Of Rig Machine, Mast Hoisting And Casing Drilling ( Upto 6 Mtr. ) Placement Of Casing With All Allied Works Necessary To Commence Drilling Woks And Wind Up Of All Machineries After Completion Of Drilling. 34 Transportation Cost Of Drilling Equipment And Accessories Rig Machine Etc. Including Cost Of Fuel, Lubricant & Loading Unloading The Materials From Store / Stack Yard / Suppliers Godown And Unloading / Stacking The Same At Site. ( Upto 60.0 Km Distance ) 35 Lowering The Tube Well Assembly ( Upvc Casing Pipe , Well Pipe, Strainer Along With Upvc Accessories ) Vertically In A Position With Proper Lowering Arrangement By Applying Necessary Jointing Compound Including Labour Cost For Subsequent Gravel Packing And Machine Operation Cost Etc 36 Cost Of Consumables For Drilling Rigs And Machineries. 37 Supply And Delivery Of Upvc Pipe ( Cd ) Conforming To Is 12818:2010. ( Cipet Certified ) A ) 250 Mm Dia. 38 B ) 200 Mm Dia. 39 Supply And Delivery Of Upvc Deep Well Screen ( Rds ) Pipes With Ribs Conforming To Is 12818:2010 . ( Cipet Certified ) A ) 200 Mm Dia. 40 Supply And Delivery Of Upvc Reducera ) 250Mm X 200 Mm Dia. 41 Supply And Delivery Of Upvc Capa ) 200 Mm Dia. 42 B ) 250 Mm Dia. 43 Supply And Delivery Of M.S. Housing Clamp 250 Mm Dia. 44 Supply And Delivery Of M.S .Centre Guide ( Special Type ) . 45 Development ( Min. 8 Hr. Continuous ) Of Tube Well By Using Suitable Air Compressor ( Min. Capacity: 600Cfm & Operating Pressure 14 Bar ) Followed By Yield Testing With Bht Pump ( Head :45 To 50Mtr., Discharge :1100 To 1000 Lpm And 25 Bhp Engine ) All Complete Including To & Fro Transportation Cost And Cost Of Fuels, Lubricants & Labour Etc. 46 Water Sample Collection And Chemical Test Including Arsenic Test. 47 Protective Sealing The Annular Space Between Tube Well Pipes & The Bore By Bentonite Clay Balls / Cement Slurry Above The Shrouded Gravels ( 3 M. Height ) . 48 Packing The Annular Space Between The Outsides Of The Housing Pipe & The Bore With Puddle Clay Balls Of Approved Size As Per Direction Of E.I.C. Including Cost Of All Materials, Labour Complete. 49 Supply And Delivery Of Bentonite Powder Conforming To Is 6186 :1986. 50 Labour For Making Arrangement For Showing Verticality Test Including The Cost For Hire Charges Of Tools And Plants, Scafolding, Labour Etc. All Complete 51 Rising Cum Delivery Mainsupply Of Cidf & Specials As Per Is 1338-1992 52 Supply And Delivery Of Cidf Sluice Valve As Per I.S 14484-2000 ( Upadhaya / L&T / Kirlosker / Venus / Hazra ) I.S.I Make P.N -1.6.I ) 150 Mm Dia. 53 Ii ) 200 Mm Dia. 54 Iii ) 250 Mm Dia. 55 Supply Of C.I. Jeffy Coupling ( Flexible ) Joint Complete With Studtsnuts Bolts, Rubbon Sealing Reing As Per I.S.Specification.I ) 150 Mm Dia. 56 Ii ) 200 Mm Dia. 57 Iii ) 250 Mm Dia. 58 Carrying Ci / Di Pipes With Specials And Valves And Lowering Placing In Position And Laying Carefully Inside The Trenches In Proper Alignment And Gradient Etc. Including Earth Work In Excavation Of Adequate Width As Per Specification Having Min. Clear Cover From Top Of Pipe Is 1.10Mtr. Below Existing Ground Level In Any Kind Of Soil Including Mixed With Boulder, Road Sub-Grade And Its Flank, But Excluding Moorum And Laterite And Stone Etc.Without Damaging The Exisiting Telephone / Electric Cable Etc. ( In Case Of Damaged If Any Type Of Cable Line During Excecution , Necessary Damaged Charges As Applicable By The Respective Authority Will Be Borne By The Agency In His Own Cost ) Preparing The Bottom Surface For Continuous Bedding Of Pipe Line And Laying Pipes, Fitting, Fixing Specials And Valves With Bailing Out Water If Any Including Carriage Of Pipes, Specials And Valves From Local Deptt. Store Within 8Km And Back Filling The Trenches With Excavated Earth In Layers To Original Condition As Per Specification And Direction Of Eic. The Surplus Materials After Execution Of Work Are To Be Return To The Deptt. Store.N.B: I ) Any Deviation From Required Clear Cover Of 1.10Mtr., Due To Site Adverse Condition, Prior Permission Is To Be Obtained From The Eic In Exceptional Situation And Payment Will Be Made On Prorate Basis Over The Rate Of Entire Itemii ) No Payment Will Be Made Without Hydraulic Test Of The Pipe Line Either Part Or Fulliii ) The Pipes, Specials And Valves , Rubber Gasket Will Be Supplied Deptt. Free Of Cost.B ) 80 Mm Dia. 59 150 Mm Dia 60 200 Mm Dia 61 250 Mm Dia 62 Filling The Pipe Line With Water, Testing Hydraulically As Per I.S 3114-1965 ( Article-6 ) In Section Of A Length Not Exceeding 500Mtr. For Head Of Pressure As Per Specification Including Supplying Installing And Fixing All Equipments Such As Diesel Pump Set, Blank Flange, Pressure Gauge, Valve, Pressure Pump And All Other Tools And Plants Including Drilling Topping And Plugging Of Necessary Holes To Pipes, Blocking Ends Providing Temporary Thrust Block And Subsequent Blocking Of Holes And Other Jointing Materials And Dismantling And Removal Of The Same Including Disposal Of Water Etc. All Complete As Per Specification And Direction Of Eic. The Rate Is Inclusive Of Cost Of Requisite Water To Be Arranged By The Contractor ( Recovery Rate Of Water @ Rs.10.00 / M3, If Contractor Used Water From Deptt. Source ) .80 Mm Dia 63 150 Mm Dia 64 200 Mm Dia 65 250 Mm Dia 66 Cleaning Thoroughly The Inner Surface Of Pipe Line Including Specials And Valves By Flushing With Water And Subsequently Disinfection Of The Same Pipe Line By Flushing Again With Water Containing Bleaching Powder Resulting In Residual Chlorine Not Less Than 15Mg / Ltrs. After 24Hrs. Of Such Filling Including Laboratory Testing Of Water Samples Obtain From The Disinfested Pipe Line And Disposal Of Water From The Pipe Line After Completion Of The Work. The Rates Including Of Cost Of Requisite Water To Be Arranged By The Contractor ) ( The Rate Of Water @Rs. 10 / M3 May Be Recovered, If The Contractor Used Water From Deptt. Source ) .80 Mm Dia 67 150 Mm Dia 68 200 Mm Dia 69 250 Mm Dia 70 Labour For Horizontal Boring Under Pucca Road Etc…………....For Laying Of Pipe.I ) Up To 150 Mm Dia. ( Ci / Di / Ac / Gi ) / 180 Mm O.D Upvc & Hdpe 71 Making Rubber Gasket Joint To Ci / Di Pipes Maintaining Proper Alignment Level Etc. By Mechanical Arrangement With Or Without Using Mobile Cranes Where Necessary And With Help Of All Other Equipments Tools And Tackles Etc. As Required Providing Lubricants Of Approved Quality And Direction Of Eic. ( Rubber Gasket Will Be Supplied Deptt. Free Of Cost ) B ) 150 Mm Dia. 72 C ) 200 Mm Dia. 73 E ) 250 Mm Dia. 74 Making Flange Joint To Di / Ci Pipes, Specials And Valves Where Necessary With Supply Of Required Rubber Insertion And Nut Bolts, Washers Etc. Of Approved Quality And Type All Complete As Per Specification And Direction Of Eic ( Nut And Bolts Shall Be Of Tata / Gkw Rate ) .B ) 100 Mm Dia. 75 A ) 80 Mm Dia. 76 C ) 150 Mm Dia. 77 D ) 200 Mm Dia. 78 D ) 250 Mm Dia. 79 Construction Of Different Dia Sluice Valve / Air Valve / Washout Chamber In Different Sizes For Village Road Where Light Traffic Run And For Main Road Where Heavy Traffic Run As Deptt.Approved Drawing With 25Cm Thick Brick Work ( 1:6 ) Over Cement Concrete ( 4:2:1 ) Over A Single B / F Soling Over150mm.Thick Sand Filling In Foundation Including Earth Work In Excavation And Disposal Of Excess Earth From Work Site With Rcc ( 1:1.5:3 ) Cover Slab 100Mm / 150Mm Thick Slab On Top Of Chamber With 1% Reinforcement In Rcc Cover Slab With Necessary Opening For Operation Of Valve All Complete Including Cost Of Labour & Materials As Per Departmental Dwg. [ Reinforcement Type:- Other Manufactuerers Not Specified ] I ) 80 Mm To 150 Mm Dia Pipe 80 I ) 200 Mm Dia Pipe 81 I ) 250 Mm Dia Pipe 82 Cutting Di Pipe ( All Class & Type ) To Required Length With Cutting Device Etc. And Grinding The Cutting Portion With File As Per Direction And Satisfaction Of Eic.B ) 150Mm.Dia.To 200Mm.Dia Pipe 83 Carriage Of Different Type Of Departmental Pipes From Divisional / Sub-Divisional Store To The Work Site By Truck Including Loading, Unloading, Stacking Etc. Including Cost Of Fuel, Lubricant And Also Cost Of Driver, Helper Etc. And All Other Taxes And Charges As Applicable As Per Direction Of Eic.Upto 20 Km ( Above 50 Km Extra Cost 57 Rs / Km ) 84 Hw Site P / Houseearth Work In Excavation Of Foundation Trenches Or Drains, In All Sorts Of Soil ( Including Mixed Soil But Excluding Lateriatc Or Sandstone ) Including Removing, Spreading Or Stacking The Spoils Within A Lead Of 75 M. As Directed. The Item Includes Necessary Trimming The Sides Of Trenches, Leveling, Dressing And Ramming The Bottom, Bailing Out Water As Required Complete.A ) Depth Of Excavation Not Exceeding 1.500 Mm. 85 Earth Work In Filling In Foundation Trenches Or Plinth With Good Earth In Layers Not Exceeding 150Mm Including Watering And Ramming Etc. Layer By Layer Complete. ( Payment To Be Made On The Basis Of Measurement Of Finished Quantity Of Work ) A ) With Earth Obtained From Excavation Of Foundation 86 Filling In Foundation Or Plinth By Silver Sand In Layers Not Exceeding 150 Mm As Directed And Consolidating The Same By Thorough Saturation With Water, Ramming Complete Including The Cost Of Supply Of Sand. ( Payment To Be Made On Measurement Of Finished Quantity ) . 87 Single Brick Flat Soling Of Picked Jhama Bricks Including Ramming And Dressing Bed To Proper Level And 1Illing Joints With Local Sand. 88 Cement Concrete With 30 Mm Down Graded Shingles Excluding Shuttering ( N.B. Variety ) . In Ground Floora ) 6:3:1 Proportion 89 Ordinary Cement Concrete Mix 1:1.5:3 ) With Graded Stone Chips ( 20 Mm Nominal Size ) Exciuding Shuttering And Reinforcement If Any, In Ground Floor As Per Relevant Is Codes.River Bazree 90 A ) 25 Mm To 30 Mm Shuttering Without Staging, In Foundation 91 B ) 25 Mm To 30 Mm Thick Wooden Shuttering As Per Decision & Direction Of E.I.C. In Foundation. 92 Reinforcement For Reinforced Concrete Work In All Sorts Of Structures Including Distribution Bars, Stirrups, Binders Etc Initial Straightening And Removal Of Loose Rust ( If Necessary ) , Cutting To Requisite Length, Hooking And Bending To Correct Shape, Placing In Proper Position And Binding With 16 Gauge Black Annealed Wire At Every Intersection, Complete As Per Drawing And Direction. ( A ) For Works In Foundation And Upto Roof Of Ground Floor / Upto 4 M ( I ) Other That Tor Steel / Mild Steelsail / Tata / Rinl 93 Brick Work With Ist Class Bricks In Cement Mortar ( 1:6 ) ( A ) In Foundation And Plinth 94 B ) In Superstucture, Ground Floor. 95 Artificial Stone In Floor, Itado, Staircase Etc. With Cement Concrete ( 1:2:4 ) With Stone Chips, Iaid In Panels As Directed With Topping Made With Ordinary Or White Cement ( As Necessary ) And Marble Dust In Proportion ( 1:2 ) Including Smooth Finishing And Rounding Off Corners Including Raking Out Joints Or Roughening Of Concrete Surface And Application Of Cement Slurry Betore Flooring Works Using Cement 175 Kg / Sq.M All Complete Including All Materials And Labour.In Ground Floor. ( I ) 35 Mm. Thick 96 Wood Work In Door And Window Frame Fitted And Fixed In Position Complete Including A Protective Coat Of Painting At The Contact Surface Of The Frame Exluding Cost Of Concrete, Iron Butt Himges And M.S Clamps. ( The Quantum Should Be Correted Upto Three Decimals ) .A ) Sal: Siliguri 97 Supplying, Fitting And Fixing M.S. Clamps For Door And Window Frame Made Of Flat Bent Bar, End Bifurcated With Necessary Screws Etc. By Cement Concrete ( 1:2:4 ) As Per Direction. ( Costof Concrete Will Be Paid Separately ) ( I ) 40Mm X Bmm, 200Mm Length 98 Supplyof Fan Hook. 99 Plaster ( To Wall, Floor, Ceiling Etc. ) With Sand And Cement Mortar Including Rounding Off Or Chamfering Corners As Directed And Raking Out Joints Including Throating, Nosing And Drip Course, Scaffolding / Staging Where Necessary ( Ground Floor ) . [ Excluding Cost Of Chipping Over Concrete Surface.I ) With 1:6 Cement Mortara ) 20 Mm Thick Plaster 100 B ) 15 Mm Thick Plaster 101 Ii ) With 1:4 Cement Mortarc ) 10 Mm Thick Plaster 102 Neat Cement Punning About 1.5 Mm Thick In Wall, Dado, Window Sills, Floor, Drains Etc 103 Applying Decorative Cement Based Paint Of Approved Quality After Preparing The Surface Including Scraping The Same Thoroughly ( Plastered Or Concrete Surface ) As Per ManufacturerS Specification.In Ground Floor ( I ) One Coat On New Surface 104 Ii ) Two Coats. 105 Protective And Decorative Acrylic Exterior Emulsion Paint Of Approved Quality, As Per ManufacturerS Specification And As Per Direction Of Eic To Be Applied Over Acrylic Primer As Required. The Rate Includes Cost Of Material, Labour, Scaffolding And All Incidental Charges But Excluding The Cost Of Primer.A ) In Ground Floor ( Two Coat ) ( I ) Normal Acrylic Emulsion 106 A ) Priming One Coat On Timber Or Plastered Surface With Synthetic Oil Bound Primer Of Approved Quality Including Smoothening Surfaces By Sand Papering Etc 107 ( B ) Priming One Coat On Steel Or Other Metal Surface With Synthetic Oil Bound Primer Of Approved Quality Including Smoothening Surfaces By Sand Papering Etc. 108 Painting With Best Quality Synthetic Enamel Paint Of Approved Make And Brand Including Smoothening.Surtace By Sand Papering Etc. Including Using Of Approved Putty Etc. On The Surface, If Necessary. ( A ) On Timber Or Plastered Surface With Super Gloss ( Hi-Gloss ) .Two Coat ( With Any Shade Except White 109 B ) On Steel Surfacei ) One Coat ( With Any Shade Except White 110 Panel Shutters Of Door And Window, Asper Design ( Each Panel Consisting Of Single Plank Without Joint ) , Including Fitting And Fixing The Same In Position But Excluding The Cost Of Hinge And Other Fittings. In Ground Floor. ( I ) 35 Mm Thick Shutters With 19 Mm Thick Panel Of Size 30 To 45 Cm.A ) Sishu, Gamar, Champ, Bhola, Mogra, Hallak. 111 Glazed Shutter Of Door , Windows, Fan Light Clerestory Window Etc. As Per Designe ( With Ordinary Glassof 7.4 Kg / Sq.M. 3 Mm Thick ) Fitted With Putty Bed And Teak Wood Bead Cost Of Hings And Other Fittings And Fixing Shutter In Position But Excluding The Cost Of Hinges And Other Fittings .Cost Of Glass Putty Wooded Beads Etc Will Be Separately.35 Mm Thick Shutter .A ) Sishu, Gamar, Champ, Bhola, Mogra, Hallak. 112 Sipplyng Best Indian Sheet Glass Panes Set In Putty And Fited And Fixrd Witlh Ails And Putty Conmplete. ( In All Floors For Internal Wall& Upto 6 Nm Height For External Wall. ( I ) 4 Mm Thick 113 Ms.Or W.I Ornamental Grill Of Approved Design Joints Continuously Welded With M.S.W.Flats And Bars Of Windows, Railing Etc. Fitted And Fixed With Necessary Screws And Lugs In Rround Floor. ( I ) Gril Weighing Above 10 Kt. / Sq Mtr And Up To 16 Kg. / Sq, Mtr. 114 I ) 300 Mm.Iron Hasp Bolt Of Approved Quality Fitted And Fixed Complete ( Oxidised ) With 16Mm Dia Rod With Centre Bolt And Round Fitting. 115 ( I ) 150 Mm X5.5 Mm .Iron Door Handle Of Approved Quality Fitted And Fixed Complete: 116 ( Ii ) 100 Mm X 5 Mm. 117 I ) Sal Siliguri.A ) With 75 Mm Iron Butt-Hingesupplying, Fitting And Fixing Hinge Cleat In Position Excluding The Cost Hinge And Other Fittings. 118 I ) Sal: Siliguri.B ) With 50 Mm Iron Butt-Hinge 119 Iron Butt Hinges Of Approved Quality Fitted And Fixed With Steel Screws, With Isi Mark.I ) 50 Mm. X 37Mm. X 1.50Mm 120 ( I ) 75Mm. X 40Mm. X 1.12Mm. 121 ( I ) 100Mm. X 50Mm. X 1.25Mm 122 Iron Socket Bolt Of Approved Quality Fitted And Fixed Complete.A ) 100Mm Long X 10Mm Dia Bolt. 123 B ) 150Mm Long X 10Mm Dia Bolt. 124 Chalmp For Fan Light Fitted & Fixed Complete 125 Precast Pierced Concrete Jally Work As Per Design And ManufacturerS Specification Including Moulding Etc. With Stone Chips And Necessary Reinforcement Shuttèring Complete Including Fitting, Fixing In Position In All Floors. ( A ) 37.5 Mm Thick Panels 126 Supplying P.V.C. Water Storage Tank Of Approved Quality With Closed Top With Lid ( Black ) -Multilayer ( A ) 500 Litre Capacity. 127 Labour For Hoisting Plastic Water Storage Tank 128 Supplying, Fitting And Fixing G.I. Pipes Of Tata Make With All Necessary Accessories, Specials Viz. Socket, Bend, Tee, Union, Cross, Elbo, Nipple, Longscrew, Reduing Socket, Reducing Tee Short Piece Etc. Fitted With Holder Bats Clamps, Including Cutting Pipes, Making Threads Fitting, Fixing Etc. Complete In All Respect Including Cost Of All Nece [ Sarý Fittings Required, Jointing Materials And Two Coats Of Painting With Approved Paint In Any Position Above Ground. ( Payment Will Be Made On The Centre Line Measurements Of Total Pipe Line Includingall Pecials.No Separate Payment Will Be Made For Accesories, Specials. ( Payment For Painting Will Be Made Seperately ) ( I ) 25 Mm Dia. Medium Quality 129 ( Ii ) 15 Mm Dia. Medium Quality 130 Labour For Punching Hole In Plastic Water Storage Tank Upto 50 Mm Dia. 131 Supplying, Titting And Fixing Gunmetal Wheel Valve Of Approved Brand And Make Tested To 21Kg Per Sq. Cm. ( For Water Lines Only ) .I ) 25 Mm Dia. 132 Ii ) 20 Mm Dia. 133 Supplying, Fitting And Fixing Alloy Iron With Brass Spindle Bib Cock / Stop Cock Of Approved Brand And Make, Spray Painted And Tested To 21 Kg Per Sq. Cm.I ) 15 Mm Dia 134 Supply Of Upvc Pipes & Fittings Etc. Conforming To Is-13592-1992I ) Door Tee 110 Mm 135 Ii ) Vent Cowl 110 Mm 136 ( Ii ) Door Bend ( T.S. ) 110 Mm 137 Supply Of Upvc Pipes ( B Type ) & Fittings Conforming To Is-13592-1992A ) Single Socket 3 Meter Length. ( I ) 110 Mm . 138 Orissa Pattern Water Closet In White Glazed Vitreous Chinaware Of Approved Make In Position . ( I ) 530 Mm X 410 Mm. 139 Supplying , Fitting , Fixing Cast Iron P Or S Trap Conforming To Is: 3989 / 1970 / And 1729 / 1964 Incl. Lead Caulked Joints And Painting Two Coats To Exposed Surface . ( Painting To Be Separately ) .A ) S Trap I ) 100 Mm Dia . 140 Supplying , Fitting , Fixing, 10 Liter P.V.C. Low-Down Cistern Conforming To I.S Specification With P.V.C. Fittings Complete.C.I. Brackets Incl. Two Coats Of Painting To Bracket Etc.I ) White 141 Construction Of Inspection Chamber Measure 600Mm X 600Mm X Upto 600Mm ( Depth ) With250 Mm Thick 1St Class Brick Wwk In Cement Mortr ( 1:4 ) On All Sides, Bottom Of The Pit Conuntng Of 100 Mm Thick Cement Concrete ( 1:3:6 ) With Stone Chips Over A Layer Of Jhama Brick Flat Soling15 Mm Thick ( 1:4 ) Cenent Plster To Inside Walls.A ) With Bazree ( N.B Varity ) 142 Constrution Of Septic Tank Of Differont Apacities As Per Approved Drawng Wilh 1St Class Bck Work M Cement Mortar ( L:4 ) Includng Two 560 Mm Dia. R.C.C. Manhole Cover ( Heavy Type ) Ot Approved Make Supplod, Iitted And Fned In The 100M Thick R.C.C ( I:1.5:3 ) Top Slab With Necessary Fittings, 20Mm Thick Cement Plaster ( 4 :1 ) With Neat Cement Finish To The Internal Surfaces And 15 Mm Thick Cement Plaster ( 4 :1 ) To Outside Wall Upto 200 Mm Below6. Floor Tunished With 25 Mm Thick Grey Artificata ) For 10 Usersi ) With Baztee [ N.B Varitv ] 143 Construction Of Circular Soak Well 2.5 Metre Deep In All Types Of Sandy Soils With Dry Brick Work Upto 1.6 Metre From The Bottom Having 150 Mm Intermediate Ceiment Brick Work ( 1:4 ) Band All Round And Cement Brick Work ( 1:4 ) Upto 0.90 Metre From Top With 20Mm Thick Cement Plastering ( 1:4 ) To Inside Face Upto The Depth Of Cement Brick.With 250 Mm Thick Dry Brick Work And 250 Mm Thick Cement Brick Work ( 1:6 ) And 1.00 M Inside Dia. 144 125 Mm. Thick Brick Work With 1St Class Bricks In Cement Mortar ( 1:4 ) In Ground Floor 145 Supplying. Fitting And Fixing Fibre Reinforced Polymer ( Frp ) Composite Door Frame As Per Approved Section With Glass Fibre Reinforced Plastic Mouided Skins And A Special Sandwich Core, So As To Impart Monolitaheic Composite Structure As Per Approved Technologydepartment Of Science And Technology ( Dst ) To Safisty Is: 4020 Door Testing Performanc ( I ) 66 Mm X 90 Mm 146 Supplying Fitting Fixing Best Quality Digital Printed Ceramic Tiles In Colour Decorative In Wall 1& Ftloor To Match With.Complete. 147 Hw Site Boundary Wallearth Work In Excavation Of Foundation Trenches Or Drains, In All Sorts Of Soil ( Including Mixed Soil But Excluding Lateriatc Or Sandstone ) Including Removing, Spreading Or Stacking The Spoils Within A Lead Of 75 M. As Directed. The Item Includes Necessary Trimming The Sides Of Trenches, Leveling, Dressing And Ramming The Bottom, Bailing Out Water As Required Complete.A ) Depth Of Excavation Not Exceeding 1.500 Mm. 148 Earth Work In Filling In Foundation Trenches Or Plinth With Good Earth , In Layers Not Exceeding 150Mm. Including Watering And Ramming Etc. Layer By Layer Complete ( Payment To Be Made On The Basis Of Measurement Of Finished Quantity Of Work ) A ) With Earth Obtained From Excavation Of Foundation. 149 Cement Concrete ( 1:3:6 ) With 30 Mm Down Graded Excluding Shuttering.A ) 6:3:1 Proportion. 150 Ordinary Cement Concrete M-20 ( Mix 3:1:5;1 ) With Graded Stone Chips ( 20 Mm Down ) Excluding Shuttering And Reinforcement .If Any , In Ground Floor, As Per I.S. 456-2000.I ) River Bozree. 151 Reinforcement For Reinforced Concrete Work In All Sorts Of Structures Including Distribution Bars, Stirrups, Binders Etc Initial Straightening And Removal Of Loose Rust ( If Necessary ) , Cutting To Requisite Length, Hooking And Bending To Correct Shape, Placing In Proper Position And Binding With 16 Gauge Black Annealed Wire At Every Intersection, Complete As Per Drawing And Direction. ( A ) For Works In Foundation And Upto Roof Of Ground Floor / Upto 4 M ( I ) Other That Tor Steel / Mild Steelsail / Tata / Rinl 152 Hire And Labour Charges For Shuttering With Centreing And Necessary Staging Up To 4M Using Approved Stout Props And Thick Hard Wood Planks Of Approved Thickness With Required Bracing For Concrete Slab . Beams , Columns, Lintels Curved Or Straight Including Fitting Fixing And Striking Out Of Completion Of Works ( Up To Roof Of Ground Floor ) .A ) 25 Mm To 30 Mm Thick Shuttering With Out Staging And Foundation Etc, 153 B ) ) 25 Mm To 30 Mm Thick Wooden Shutter As Per Decision & Direction Of Engineer-In-Charge. 154 Plaster ( To Wall, Floor , Ceiling Etc, ) With Sand And Cement Mortar Including Rounding Off Chamfering Corners As Directed And Raking Out Joints Or Roughening Of Concrete Surface Including Throating , Nosing And Drip Course Where Necessary ( Ground Floor ) .. With Cement Mortar ( 6:1. ) .15 Mm Thick Plaster. 155 With Cement Mortar ( 6:1. ) .20 Mm Thick Plaster. 156 With Cement Mortar ( 4:1 ) 10 Mm Thick. 157 Neat Cement Punning About 1.5Mm Thick In Wall , Dado , Window, Sills Floor Drain Etc, 158 Priming One Coat On Timber Plastered Or On Steel Or Other Metal Surface With Synthetic Enamel / Oil Bound Primer Of Approved Quality Including Smoothening Surface By Sand Preparingetcon Timber . 159 Painting With Best Quality Synthetic Enamel Paints Of Approved / Make And Brand Including Smoothening Surface By Sand Preparing Etc, Including Using Of Approved. Putty Etc, On The Surface Of Necy.I ) On Timber Or Plastered Surface. With Super Gloss ( Hi-Gloss ) .A ) One Coats ( With Any Shade Except White ) 160 Protective Decorative Acrylic Exterior Emulsion Paint Of Approved Quality As Per Manufacturer’S Specification And As Per Direction Of Eic To Be Applied Over Acrylic Primer As Required . The Rate Includes Cost Of Materials , Labour , Scaffolding And All Incidental Charges But Excludingthe Cost Of Primer.A ) Normal Acrylic Emulsion. ( I ) Two Coat 161 Earth Work In Filling Compound , Tank , Low Sand Ditches Etc, Good Earth, In Layer Not Exceeding 250Mm Including Breaking Clods & Consolidating The Same By Ramming And Dressing Complete Etc. Layer By Layercompletei ) With Carried Earth Arrangement By The Contractor Within A Radius Of 3Km Including The Cost Of Carriage But Not Exceeding 5Km 162 M.S. & Wi Ornamental Grill Of Approved Design Joints Continuously Welded With Ms.Wi. Flats And Bars Of Windows Railing Etc. Fitted And Fixed With Necessary Screws Andlugs In Ground Floor. ( I ) Grill Weighing Above 10Kg / Sq.M. And Up To16kg / Sqm. 163 125 Mm Thick Brick Work With 1St Class Bricks In Cement Mortar ( 1:4 ) With1st Class Brick In All Floor. 164 2Nd Site P / Houseearth Work In Excavation Of Foundation Trenches Or Drains Or Septic Tank Soak Well Etc. In All Sorts Of Soil ( Including Mixed Soil But Excluding Latarite Or Sand Stone ) Including Removing Spreading Or Stack-Ingthespoilswithinaleadof75m.Asdirected.Theitem Includesnecessarytrimmingthesidesofthetrenches, Leveling Dressing And Ramming The Bottom, Bailing Or Pumping Out Water Etc. Asrequiredcomplete. Depthofexcavationnotexceeding1.5Mtr. But Not Requiring Shoring 165 Earth Work In Filling In Foundation Trenches Or Plinth With Good Earth In Layers Not Exceeding 15Cm. Including Watering And Ramming Etc. Layer By Layer Complete. ( Payment To Be Made On Basis Of Measurementof Finishedquantity Ofwork ) A. With Earth Obtained From Excavation Of Foundation 166 Filling In Foundation Or Plinth By Fine Sand In Layers Not Exceeding 150 Mm As Directed & Consolidating Same By Throughsaturationwithwaterandramming Completeincluding The Costofsupplyofsand. ( Paymenttobemadeonthebasisof Measurement Of Finished Quantity Of Work. ) ( A ) By Fine Sand. 167 Singlebrickflatsolingofpicked Jhamabricksincludingramming&Dressingbedtoproperlevel& Fillingjointswithpowderedearthorlocalsandincludingcostof Sand Etc Complete As Per Direction & Specification. 168 Cement Concrete With 30 Mm Down Graded Shinglesexcluding Shuttering ( N.B. Variety ) . In Ground Floora ) 6:3:1 Proportion. 169 Ordinarycementconcrete ( Mix1:1.5:3 ) Withgradedstonechips ( 20Mmnominalsize ) Excluding Shuttering And Reinforcement If Any, In Ground Floor As Per Relevant Is Codes. ( I ) River Bazree 170 Hire And Labour Charges For Shuttering With Centering And Necessary Staging Upto 4 M. Using Approvedstoutpropsandthickhardwoodplanksofapprovedthicknesswithrequired Bracing For Concrete Slabs, Beams, Columns, Lintels Curved Or Straight Including Fitting, Fixing And Striking Out After Completion Of Works ( Upto Roof Of Ground Floor ) .A ) 25 Mm To 30 Mm Shuttering Without Staging In Foundation. 171 B ) 25 Mmto30 Mmthick Wooden Shuttering Asper Decision& Ddirectionofthee.I.C. In Foundation. 172 Reinforcement For Reinforced Concrete Work In All Sorts Of Structures Including Distribution Bars, Stirrups, Binders Etc Initial Straightening And Removal Of Loose Rust ( If Necessary ) , Cutting To Requisite Length, Hooking And Bending To Correct Shape, Placing In Proper Position And Binding With 16 Gauge Black Annealed Wire At Every Intersection, Complete As Per Drawing And Direction. ( A ) For Works In Foundation And Upto Roof Of Ground Floor / Upto 4 M ( I ) Other That Tor Steel / Mild Steelsail / Tata / Rinl 173 Brick Work With 1St Class Bricks In Cement Mortar ( 1:6 ) ( A ) In Foundation And Plinth 174 ( B ) In Superstructure, Ground Floor 175 Artificial Stone In Floor, Dado, Staircase Etc. With Cement Concrete ( 1:2:4 ) With Stone Chips, Laid In Panels As Directed With Topping Made With Ordinary Or White Cement ( As Necessary ) Andmarbledustinproportion ( 1:2 ) Includingsmoothfinishingandroundingoffcorners Includingrakingoutjointsorrougheningofconcretesurfaceandapplicationofcement Slurrybeforeflooringworksusingcement@1.75Kg / Sq.Mallcompleteincludingall Materials And Labour.In Ground Floor. ( I ) 35 Mm. Thick 176 Woodworkindoorandwindowframefittedandfixedinpositioncompleteincludinga Protective Coatofpainting Atthe Contactsurface Ofthe Frameexluding Costofconcrete, Iron Butt Hinges And M.S Clamps. ( The Quantum Should Be Correted Upto Three Decimals ) .A ) Sal : Siliguri 177 Supplying, Fitting And Fixing M.S. Clamps For Door And Window Frame Made Of Flat Bent Bar, End Bifurcated With Necessary Screws Etc. By Cement Concrete ( 1:2:4 ) As Per Direction. ( Cost Of Concrete Will Be Paid Separately ) ( I ) 40Mm X 6Mm, 200Mm Length 178 Plaster ( To Wall, Floor, Ceiling Etc. ) With Sand And Cement Mortar Including Rounding Off Or Chamferingcornersasdirectedandrakingoutjointsincludingthroating, Nosingand Drip Course, Scaffolding / Staging Where Necessary ( Ground Floor ) . [ Excluding Cost Of Chipping Over Concrete Surface ( I ) With 1:6 Cement Mortar ( A ) 20 Mm Thick Plaster 179 ( B ) 15 Mm Thick Plaster 180 ( Ii ) With 1:4 Cement Mortar ( A ) 10 Mm Thick Plaster 181 Neat Cement Punning About 1.5 Mm Thick In Wall, Dado, Window Sills, Floor, Drains Etc. 182 Applyingdecorativecementbasedpaintofapprovedqualityafterpreparingthesurface Includingscrapingthesamethoroughly ( Plasteredorconcretesurface ) Asper ManufacturerS Specification.A ) In Ground Floor: ( I ) Two Coats. 183 Protectiveanddecorativeacrylicexterioremulsionpaintofapprovedquality, Asper ManufacturerS Specification And As Per Direction Of Eic To Be Applied Over Acrylic Primer As Required. The Rateincludes Costofmaterial, Labour, Scaffoldingand Allincidental Charges But Excluding The Cost Of Primer.A ) In Ground Floor ( Two Coat ) ( I ) Normal Acrylic Emulsion 184 ( A ) Primingonecoatontimberorplasteredsurfacewithsyntheticoilboundprimerof Approved Quality Including Smoothening Surfaces By Sand Papering Etc. 185 ( B ) Primingonecoatonsteelorothermetalsurfacewithsyntheticoilboundprimerof Approved Quality Including Smoothening Surfaces By Sand Papering Etc. 186 Paintingwithbestqualitysyntheticenamelpaintofapprovedmakeandbrandincluding Smootheningsurfaceby Sandpaperingetc.Includingusingofapproved Puttyetc.Onthe Surface, If Necessary : ( A ) On Timber Or Plastered Surface : With Super Gloss ( Hi-Gloss ) -I ) Two Coat ( With Any Shade Except White ) 187 ( B ) On Steel Surface : With Super Gloss ( Hi-Gloss ) -I ) One Coat ( With Any Shade Except White ) 188 Panelshuttersofdoorandwindow, Asperdesign ( Eachpanelconsistingofsingleplank Withoutjoint ) , Includingfittingandfixingthesameinpositionbutexcludingthecostof Hinge And Other Fittings.In Ground Floor. ( I ) 35Mm Thick Shutters With 19Mm Thick Panel Of Size 30To 45 Cm.A ) Sishu, Gamar, Champ, Badam, Bhola, Mogra, Hallak. 189 Glazedshuttersofdoors, Windows, Fanlight, Clerestorywindowsetc.As Perdesign ( With Ordinary Glass Of 7.4Kg. / Sq.M. 3Mm. Thick ) Fitted With Putty Bed And Teak Wood Bead And Nailsincludingfittingandfixingshutterinpositionbutexcludingthecostofhingesand Other Fittings. Cost Of Glass, Putty, Wooded Beads Etc.Will Be Paid Separately. ( I ) 35Mm Thick Shutters.A ) Sishu, Gamar, Champ, Badam, Bhola, Mogra, Hallak. 190 Supplying Best Indian Sheet Glass Panes Set In Putty And Fitted And Fixed With Nails And Putty Complete. ( In All Floors For Internal Wall & Upto 6 M Height For External Wall ) ( I ) 4 Mm Thick 191 M.S.Or W.I. Ornamental Grill Of Approved Design Joints Continuously Welded With M.S, W.I. Flatsand Barsofwindows, Railingetc.Fittedand Fixedwithnecessaryscrewsandlugsin Ground Floor.I ) Grill Weighing Above 10 Kg. / Sq.Mtr And Up To 16 Kg. / Sq. Mtr. 192 Iron Hasp Bolt Of Approved Quality Fitted And Fixed Complete ( Oxidised ) With 16Mm Dia Rod With Centre Bolt And Round Fitting.I ) 300 Mm 193 Iron Door Handle Of Approved Quality Fitted And Fixed Complete: ( I ) 150Mm X 5.5Mm. 194 ( Ii ) 100Mm X 5Mm. 195 Supplying, Fittingandfixinghingecleatinpositionexcludingthecosthingeandother Fiffitngs.A ) With 75Mm Iron Butt-Hingei ) Sal : Siliguri. 196 B ) With 50Mm Iron Butt-Hingei ) Sal : Siliguri. 197 Iron Butt Hinges Of Approved Quality Fitted And Fixed With Steel Screws, With Isi Mark. ( I ) 50Mm. X 37Mm. X 1.50Mm. 198 ( Ii ) 75Mm. X 40Mm. X 1.12Mm. 199 ( Iii ) 100Mm. X 50Mm. X 1.25Mm. 200 Iron Socket Bolt Of Approved Quality Fitted And Fixed Complete. ( A ) 100Mm Long X 10Mm Dia Bolt. 201 ( B ) 150Mm Long X 10Mm Dia Bolt. 202 Cord For Fan Light Fitted & Fixed Complete. 203 Precast Pierced Concrete Jally Work As Per Design And ManufacturerS Specification Including Moulding Etc. With Stone Chips And Necessary Reinforcement Shuttering Complete Including Fitting, Fixing In Position In All Floors. ( A ) 37.5 Mm Thick Panels 204 Supplyingp.V.C.Waterstoragetankofapproved Qualitywithclosed Topwith Lid ( Black ) - Multilayer ( A ) 500 Litre Capacity 205 Labour For Hoisting Plastic Water Storage Tank. ( I ) Upto 1500 Litre Capacity. ( A ) Upto 1St Story From G.L. 206 Supplying, Fitting And Fixing G.I. Pipes Of Tata Make With All Necessary Accessories, Specials Viz. Socket, Bend, Tee, Union, Cross, Elbo, Nipple, Longscrew, Reducing Socket, Reducing Tee, Shortpieceetc.Fittedwithholderbatsclamps, Includingcuttingpipes, Makingthreads, Fitting, Fixing Etc. Complete In All Respect Including Cost Of All Necessary Fittings As Required, Jointing Materialsand Twocoatsofpainting With Approved Paint Inany Position Above Ground. ( Payment Will Be Made On The Centre Line Measurements Of Totalpipe Line Including All Specials. No Separate Payment Will Be Made For Accesories, Specials. Payment For Painting Will Be Made Seperately ) ( I ) 20 Mm Dia. Medium Quality. 207 ( Ii ) 15 Mm Dia. Medium Quality 208 Labour For Punching Hole In Plastic Water Storage Tank Upto 50 Mm Dia. 209 Supplying, Fitting And Fixing Gunmetal Wheel Valve Of Approved Brand And Make Tested To 21 Kg Per Sq. Cm. ( For Water Lines Only ) . ( I ) 15 Mm Dia. 210 ( Ii ) 20 Mm Dia. 211 Supplying, Fittingand Fixing Alloyironwithbrassspindlebib Cock / Stopcockofapproved Brand And Make, Spray Painted And Tested To 21 Kg Per Sq. Cm. ( I ) 15 Mm Dia. 212 Supply Of Upvc Pipes & Fittings Conforming To Is-13592-1992 ( I ) Door Tee , A ) 110 Mm 213 ( Ii ) Vent Cowl , A ) 110 Mm 214 ( Iii ) Door Bend ( T.S. ) , A ) 110 Mm 215 Supply Of Upvc Pipes ( B Type ) & Fittings Conforming To Is-13592-1992 ( A ) ( I ) Single Socketed 3 Meter Lengtha ) 110 Mm 216 Supplying, Fitting And Fixing Orissa Pattern Water Closet In White Glazed Vitreous Chinaware Of Approved Make In Position Complete Excluding P Or S Trap ( Excluding Cost Of Concrete For Fixing ) . ( I ) 530 Mm X 410 Mm 217 Supplying, Fitting And Fixing Cast Iron P Or S Trap Conformimg To I.S. 3989 / 1970 And 1729 / 1964 Including Lead Caulked Joints And Painting Two Coats To The Exposed Surface. ( Painting To Be Paid Seperately ) .A ) S Trapi ) 100 Mm Dia 218 Supplying, Fitting And Fixing 10 Litre P.V.C. Low-Down Cistern Conforming To I.S. Specification With P.V.C. Fittings Complete, C.I. Brackets Including Two Coats Of Painting To Bracket Etci ) White 219 Constructinginspectionpitofinsidemeasurement600 Mmx600mmxupto600mm ( Depth ) With 250 Mm Thick 1St. Class Brick Work In Cement Mortar ( 1:4 ) On All Sides, Bottom Of The Pit Consisting Of 100 Mm Thick Cement Concrete ( 1:3:6 ) With Stone Chips Over A Layer Ofjhamabrickflatsoling, 15Mmthick ( 1:4 ) Cementplastertoinsidewallsandout-Side Wallsuptog.L.And20mm.Thick ( 1:4 ) Plastertobottomofthepit, Providingnecessary Invert With Cement Concrete ( 1:3:6 ) With Stone Chips As Per Direction, Neat Cement Finishing Toentireinternalsurfaces, Topofthe Pitcovered With100 Mmthick R.C.C.Slab ( 1:1.5:3 ) Withstonechipsandnecessaryreinforcementsupto1%Andshutteringincluding6mm Thickcementplaster ( 1:4 ) Inallexternalsurfaces Ofthe Slaband One560 Mmdia. R.C.C. Manholecoverofapprovedmakesupplied, Fittedandfixedintheslabwithnecessary Fittings, Necessaryearthworkinexcavationinallsortsofsoil, Fillingsidesofthepitwith Earthand Removingspoilsafterworkcompleteinallrespectwith Allcostsoflabourand Materials.Ii ) With Bazree ( N.B Variety ) ( Sail / Tata / Rinl ) 220 Construction Ofseptictank Of Different Capacities Asper Approved Drawing With1st Class Brick Work In Cement Mortar ( 1:4 ) Including Two 560 Mm Dia. R.C.C. Manhole Cover ( Heavy Type ) Ofapprovedmakesupplied, Fittedandfixedinthe100mmthickr.C.C ( 1:1.5:3 ) Top Slab With Necessary Fittings, 20Mm Thick Cement Plaster ( 4 : 1 ) With Neat Cement Finish To The Internal Surfaces And 15 Mm Thick Cement Plaster ( 4 : 1 ) To Outside Wall Upto 200 Mm Below G.L Floor Finishedwith 25Mm Thick Grey Artificialstone Over 100 Mmthick R.C.C ( 1:1.5:3 ) Bottom Slabincludingsupplying, Fittingandfixingallnecessryspecials, Fittings, S.W. Tees, C.I. Foot Rest Etc. Including Excavation Earth In Allsorts Ofsoil, Shoring, Bailingoutand Pumpingoutwaterasnecessary, Ramming, Dressingthebedand Fefilling The Sides Of The Tanks With Earth, Removing Spoils, Filling Up The Chamber With Clear Water, Removing Foreign Materials From The Chamber And Including Constructing Attached Inspection Pit As Per Approved Drawing And Con In All Respectwith Allcosts Oflabour And Materials.Aterials. With 250 Mmthick Drybrick Workand 250Mmthickcement Brickwork ( 1:6 ) And 1.00M Inside Dia. By Weight Of Cement With All Costs Of Labour And Materials. ( I ) For 10 Usersa ) With Bazree ( N.B Varity ) ( Sail / Tata / Rinl ) 221 Construction Of Circular Soak Well 2.5 Metre Deep In All Types Of Sandy Soils With Dry Brick Workupto1.6Metrefromthebottomhaving150mmintermediatecementbrickwork ( 1:4 ) Bandallroundandcementbrickwork ( 1:4 ) Upto0.90Metrefromtopwith20mm Thickcementplastering ( 1:4 ) Toinsidefaceuptothedepthofcementbrickwork, 15Mm Thickcementplaster ( 1:4 ) Onouterfacefromtopofthewelluptog.L.And6mmthick Cement Plaster ( 1:4 ) On Top Of The R.C.C. Cover Slab Including Filling Bottom 1.00 Metre Of Inside Of The Well With Brick Metal ( 50 Mm To 63 Mm Size ) Including R.C.C. Cover Slab Of 100 Mmthickwithcementconc ( 1:1.5:3 ) Withstonechipswithnecessaryreinforcementand Shuttering Including One 560 Mm Dia. R.C.C. Manhole Cover ( Heavy Type ) Of Approved Make Supplied, Fittedandfixedinthecoverslabwithnecessaryfittings, Makingnacessary Arrangementsforpipeconnections, Excavationofwellincludingshoring, Dewateringand Removing The Exess Earth From The Premisesas Per Direction Completein Allrespect With All Costs Of Labour And Materials. With 250 Mmthick Drybrick Workand 250Mmthickcement Brickwork ( 1:6 ) And 1.00M Inside Dia. A ) Other Than Sail / Tata / Rinl ) 222 125 Mm. Thick Brick Work With 1St Class Bricks In Cement Mortar ( 1:4 ) In Ground Floor. 223 Carriage Of Different Type Of Departmental Pipes From Divisional / Sub-Divisional Store To The Work Site By Truck Including Loading, Unloading, Stacking Etc. Including Cost Of Fuel, Lubricant And Also Cost Of Driver, Helper Etc. And All Other Taxes And Charges As Applicable As Per Direction Of Eic A ) Above 10 Km Upto 20 Km 250 Mm Di Pipe 224 16 Mm Dia. 1Mtr Long Fan Hook 225 Supplying Fitting Fixing Best Quality Digital Printed Ceramic Tiles In Colour Decorative In Wall 1& Ftloor To Match With.Complete. 226 2Nd Site B / Wallearth Work In Excavation Of Foundation Trenches Or Drains, In All Sorts Of Soil ( Including Mixed Soil But Excluding Laterite Or Sandstone ) Including Removing, Spreading Or Stacking The Spoils Within A Lead Of 75 M. As Directed. The Item Includes Necessary Trimming The Sides Of Trenches, Levelling, Dressing And Ramming The Bottom, Bailing Out Water As Required Complete.A ) Depth Of Excavation Not Exceeding 1, 500 Mm 227 Earth Work In Filling In Foundation Trenches Or Plinth With Good Earth, In Layers Not Exceeding 150 Mm. Including Watering And Ramming Etc. Layer By Layer Complete. ( Payment To Be Made On The Basis Of Measurement Of Finished Quantity Of Work ) ( A ) With Earth Obtained From Excavation Of Foundation. 228 Earth Work In Filling In Foundation Trenches Or Plinth With Good Earth, In Layers Not Exceeding 150 Mm. Including Watering And Ramming Etc. Layer By Layer Complete. ( Payment To Be Made On The Basis Of Measurement Of Finished Quantity Of Work ) C ) ( Iii ) With Carried Earth Arranged By The Contractor Within A Radius Exceeding 3 Km. But Not Exceeding 5 Km. Including The Cost Of Carried Earth. 229 ( Ii ) Cement Concrete With 30 Mm Down Graded Shingles Excluding Shuttering. N.B. Variety ( 1:3:6 ) 230 Ordinary Cement Concrete ( Mix 1:2:4 ) With Graded Stone Chips ( 20 Mm Nominal Size ) Excluding Shuttering And Reinforcement, If Any, In Ground Floor As Per Relevant Is Codes. ( A ) River Bazree 231 Ordinary Cement Concrete ( Mix 1:1.5:3 ) With Graded Stone Chips ( 20 Mm Nominal Size ) Excluding Shuttering And Reinforcement If Any, In Ground Floor As Per Relevant Is Codes. ( I ) River Bazree 232 Reinforcement For Reinforced Concrete Work In All Sorts Of Structures Including Distribution Bars, Stirrups, Binders Etc Initial Straightening And Removal Of Loose Rust ( If Necessary ) , Cutting To Requisite Length, Hooking And Bending To Correct Shape, Placing In Proper Position And Binding With 16 Gauge Black Annealed Wire At Every Intersection, Complete As Per Drawing And Direction. ( A ) For Works In Foundation And Upto Roof Of Ground Floor / Upto 4 M ( I ) Other That Tor Steel / Mild Steelsail / Tata / Rinl 233 Hire And Labour Charges For Shuttering With Centering And Necessary Staging Upto 4 M. Using Approved Stout Props And Thick Hard Wood Planks Of Approved Thickness With Required Bracing For Concrete Slabs, Beams, Columns, Lintels Curved Or Straight Including Fitting, Fixing And Striking Out After Completion Of Works ( Upto Roof Of Ground Floor ) .F ) 25 Mm To 30 Mm Shuttering Without Staging In Foundation 234 B ) ) 25 Mm To 30 Mm Thick Wooden Shutter As Per Decision & Direction Of Engineer-In-Charge. 235 125 Mm. Thick Brick Work With 1St Class Bricks In Cement Mortar ( 1:4 ) In Ground Floor. 236 Plaster ( To Wall, Floor, Ceiling Etc. ) With Sand And Cement Mortar Including Rounding Off Or Chamfering Corners As Directed And Raking Out Joints Including Throating, Nosing And Drip Course, Affolding / Staging Where Necessary ( Ground Floor ) . [ Excluding Cost Of Chipping Over Concrete Surface ] ( I ) With 1:4 Cement Mortar A ) 10 Mm Thick Plaster 237 ( Ii ) With 1:6 Cement Mortar ( B ) 15 Mm Thick Plaster 238 ( A ) M.S.Or W.I. Ornamental Grill Of Approved Design Joints Continuously Welded With M.S, W.I. Flats And Bars Of Windows, Railing Etc. Fitted And Fixed With Necessary Screws And Lugs In Ground Floor. ( Add Extra @ 1% For Each Addl. Floor Upto 4Th Floor And @ 1.25% For Each Addl. Floor Above 4Th Floor ) ( I ) Grill Weighing Above 10 Kg. / Sq.Mtr And Up To 16 Kg. / Sq. Mtr. 239 Neat Cement Punning About 1.5Mm Thick In Wall, Dado, Window Sill, Floor Etc. 240 Priming One Coat On Timber Plastered Or On Steel Or Other Metal Surface With Synthetic Enamel / Oil Bound Primer Of Approved Quality Including Smoothening Surface By Sand Preparingetcon Timber . 241 Painting With Best Quality Synthetic Enamel Paints Of Approved / Make And Brand Including Smoothening Surface By Sand Preparing Etc, Including Using Of Approved. Putty Etc, On The Surface Of Necy.I ) On Timber Or Plastered Surface. With Super Gloss ( Hi-Gloss ) .A ) One Coats ( With Any Shade Except White ) 242 Protective Decorative Acrylic Exterior Emulsion Paint Of Approved Quality As Per Manufacturer’S Specification And As Per Direction Of Eic To Be Applied Over Acrylic Primer As Required . The Rate Includes Cost Of Materials , Labour , Scaffolding And All Incidental Charges But Excludingthe Cost Of Primer.A ) Normal Acrylic Emulsion. ( I ) Two Coat 243 Fhtcproviding Fhtc From The Existing Ci / Di / Upvc / Hdpe / Gi / Ac Distribution Pipeline By Installing 10 Mm Dia Nb Gun Metal Ferrule Conforming To Is 2692:1989 With Latest Amendments On Thesaid Pipeline And All Othersaccessories Like Saddle Piece Of Require Size To Fit The Existing Distribution Pipeline , Specials, Nut & Bolts Rubber Sheet , Washer Etc.And Laying15 Mm Nb Pvc ( Schedule 80 ) / 20 Mm Od Hdpe ( Pe 100 , Pn16 ) / 20 Mm Od Ppr-C ( Class -Sdr 7.4 / Pn16 ) Pipes Uptorequired Length With All Necessary Specials1.0 Metre Below The Ground Connecting Ferrule Including Cutting Trenches In All Sorts Of Soil And Filling Up Trenches As Per Directionsof The Engineer-In-Charge And Upto A Point Just Inside The Premises Of The House Hold Or As Directed By Eic. Supply And Installation Of A L5mm Dia. Alloy Ironbib Cock ( Tested To 2T Kg / Cm2 ) Above 1.0 Mtr. Frorn Ground, An Alloy Stop Cock Of 15 Mm Diawith Brass Spindle ( Tested Ta 21 Kg / Cm2 ) To Be Fitted In A Position As Directed By E.I.C. G.L Pipe Of Tata Make ( Mediurn Duty ) Of 2 Metre Length With All Necessary Specials To Continue From The End Of The Pvc / Hdpe / Ppr-C Pipe And Upto 1.0 M Above Ground Within The Premises Of Household.Note:1. Pvc Pipe Shall Of Schedule 80 ( Medium Duty ) Conforming To Astmd -1785And Threaded To Match With Gl Pipes As Per Is : 1239 ( Part - I ) .2. Ppr-C ( Poly Propylene Randam Copolymer ) Pipe Shall Be 3-Layer Confirming To Is :15801 Uv Stabilised & Anti-Microbiol Fusion Welded, Having Thermal Stabitity For Hot & Cold Water Supply Including All Pp-R Plain & Brass Threaded Porypropylene Random / Fittings . 3. Rate Is Exclusive Of Supply And Deliveryof10 Mm Nb Gun-Metal Ferrule.Supply & Laying Of 15Mm Nb Pvc ( Schedule 80 ) / 20Mm Od Hdpe ( Pe 100, Pn16 ) / 20 Mm Od Ppr-C ( Class -Sdr7.4 / Pn19 ) Pipes.B ) Above 10 M Upto 20 M Length 244 100 Ohrearth Work In Excavation Of Foundation Trenches Or Drains Or Septic Tank Soak Well Etc. In All Sorts Of Soil ( Including Mixed Soilbut Excluding Latarite Or Sand Stone ) Including Removing Spreading Or Stack- Ing The Spoils Within A Lead Of 75M. As Directed. The Item Includes Necessary Trimming The Sides Of The Trenches, Leveling Dressing And Ramming The Bottom, Bailing Or Pumping Out Water Etc. As Required Complete. 245 Depth Of Excavation Not Exceeding 1.5 Mtr. But Not Requiring Shoring 246 Beyond 1.5 Mtr. Upto 3.0 Mtr.But Not Requiring Shoring 247 Filling In Foundation Or Plinth By Fine Sand In Layers Not Exceeding 150 Mm As Directed & Consolidating Same By Through Saturation With Water And Ramming Complete Including The Cost Of Supply Of Sand. ( Payment To Be Made On The Basis Of Measurement Of Finished Quantity Of Work. ) ( A ) By Fine Sand. 248 Earth Work In Filling In Foundation Trenches Or Plinth With Good Earth In Layers Not Exceeding 15Cm. Including Watering And Ramming Etc. Layer By Layer Complete. ( Payment To Be Made On Basis Of Measurement Of Finished Quantity Of Work ) 249 Single Brick Flat Soling Of Picked Jhama Bricks Including Ramming & Dressing Bed To Proper Level & Filling Joints With Powdered Earth Or Local Sand Including Cost Of Sand Etc Complete As Per Direction & Specification. 250 Oridinary Cement Concrete M-15 ( Mix 1:2:4 ) With Graded Stone Chips ( 20 Mm.Down ) Excluding Shuttering And Reinforcement, If Any, In Ground Floor As Per Relevent Is Code 456-2000. From …...Concidaring 73 Km.A ) Pakur / ( Up To Ground Level ) . 251 Controled Cement Concrete With Well Graded Stone Chips ( 20 Mm Nominal Size ) Excluding Shuttering & Reinforcement With Complete Design Of Concrete As Per [ Isi : 456 And Relevant Special Publication. Submission Of Job Mix Formula After Preliminary Mix Design After Testing Of Concrete Cube As Per Direction Of The Eic. Consumption Of Cement Will Not Be Less Than 300Kg Of Cement With Super Plasticiser Per Cum. Of Controlled Conc. But Actual Consumption Will Be Determined On The Basis Of Preliminary Test & Job Mix Formuta. In Ground Floor And Foundation. [ Using Concrete Mixture ] M 25 Gradepakur Varietyfor Works In Foundation, Basement And Upto Roof Of Ground Floor / Upto4 Mtr ( Column, Bracing ) 252 4 M To 8 M ( Add Extra Over The Rate Of Ground Floor For Basement And Each Additional Floor Above Ground Floor For ( 253 8 M To 12 M ( Add Extra Over The Rate Of Ground Floor For Basement And Each Additional Floor Above Ground Floor For ( 254 12 M To 16M ( Add Extra Over The Rate Of Ground Floor For Basement And Each Additional Floor Above Ground Floor For ( 255 16 M To 20 M ( Add Extra Over The Rate Of Ground Floor For Basement And Each Additional Floor Above Ground Floor For ( 256 20 M & Above ( Landing, Step, Roof Dome, Walk Way, Platform ) ( Add Extra Over The Rate Of Ground Floor For Basement And Each Additional Floor Above Ground Floor For ( 257 Controled Cement Concrete With Well Graded Stone Chips ( 20 Mm Nominal Size ) Excluding Shuttering & Reinforcement With Complete Design Of Concrete As Per [ Isi : 456 And Relevant Special Publication. Submission Of Job Mix Formula After Preliminary Mix Design After Testing Of Concrete Cube As Per Direction Of The Eic. Consumption Of Cement Will Not Be Less Than 320Kg Of Cement With Super Plasticiser Per Cum. Of Controlled Conc. But Actual Consumption Will Be Determined On The Basis Of Preliminary Test & Job Mix Formuta. In Ground Floor And Foundation. [ Using Concrete Mixture ] M 30 Grade.In Heel Beam, Conical Slab, Bottom Dome, Bottom Ring Beam, Walkway, Shell Wall Etc. Pakur Variety16 M To 20 M ( For Heel Beam ) ( Add Extra Over The Rate Of Ground Floor For Basement And Each Additional Floor Above Ground Floor For ( 258 B ) 20 Mtr. And Above ( Cell Wall, Floor, Top & Bottom Ring Beam & Bottom Doom, Walk Way And Lantern Etc ) . ( Add Extra Over The Rate Of Ground Floor For Basement And Each Additional Floor Above Ground Floor For ( 259 Hire And Labour Charges For Shuttering With Centreing And Necy. Staging Upto 4M. Using Approved Stout Props And Thick Hard Wood Planks Of Approved Thickness With Required Bracing For Conc. Slabs, Beams, Columns, Lintels Curved Or Straight Includg. Fitting, Fixing And Striking Out After Completion Of Works.From Foundation To 4M Above Glabove 25 Mm And Upto 30 Mm Wooden Shuttering As Per Direction Of Eic. 260 Hire & Labour Chages For Shuttering For Conc. Work In Overhead R.C. Reservoir On Separate R.C. Frame Including Fitting, Fixing & Stricking Off After Completion Of Work ( From 4M To Top Of Reservoir ) . 261 Extra For Staging Beyond 4 Mtr ( Mode Of Measurement Area Of Unsupported Horizontal Projection, Where Staging Beyond 4 Mtr. Is Practically Un-Avoidable ) Staging Height To Be Considered For 4 Mtr. Above G.L. To Mean Height Of Soffit And Plan Area In Between Out Side Of Ring Beam Minus Hollow Shaft If Any And Annular Ring Beam Of Staging Above Metial 4 Mtr. 262 Reinforcement In Reinforced Conc. Work In All Sorts Of Structures Includg. Dist.Bars, Stirrups, Binders Etc., Initial Straightening And Removal Of Loose Rust ( If Necy. ) Cutting To Requisite Length, Hooking And Bending To Correct Shapde, Placing In Proper Position And Binding With 16 Gauge Balck Annealed Wire At Every Intersection, Complete As Per Drawing And Direction. ( A ) For Works In Foundn. Basement And Upto Roof Of Ground Floor / Upto 4M. ( I ) Tor Steel / Mild Steel. Sail / Tata / Rinlfor Works In Foundation, Basement And Upto Roof Of Ground Floor / Upto 4 M. 263 Extra For Works Beyond The Roof Of Ground Floor / Initial 4 M. To 8 Mtr. ( Add Extra Over The Rate Of Ground Floor / Initial 4 M For Each Basement Floor And Each Additional Floor Below / Above Ground Floor 264 8 M To 12 M ( Add Extra Over The Rate Of Ground Floor / Initial 4 M For Each Basement Floor And Each Additional Floor Below / Above Ground Floor 265 12 M To 16M ( Add Extra Over The Rate Of Ground Floor / Initial 4 M For Each Basement Floor And Each Additional Floor Below / Above Ground Floor 266 16 M To 20 M ( Add Extra Over The Rate Of Ground Floor / Initial 4 M For Each Basement Floor And Each Additional Floor Below / Above Ground Floor 267 Beyond 20 M ( Add Extra Over The Rate Of Ground Floor / Initial 4 M For Each Basement Floor And Each Additional Floor Below / Above Ground Floor 268 Supplying & Labour For Mixing Of Super Plasticizer Of Approved Make Brand Sika / Cico Conforming To Is-2645-1975 & Is-9130-1979 To Be Need In Mortar Admixture @ 0.20% By Wt. Of Cement ( I.E 100Ml Per 50Kg Of Cement ) For Improving Workability, Reducing Shrinkage And Improvement Of Water Tightness Of The Concrete. 269 ( A ) Applying 2 Coats Of Bonding Agent With Synthetic Multi Functional Rubber Emulsion Having Adhesive And Water Proofing Properties By Mixing With Water In Proportion ( 1 Bonding Agent : 4 Water : 6 Cement ) As Per ManufacturerS Specification 270 ( B ) Applying 2 Coats Of Non-Toxic Acrylic Polymer Modified Paint Having Adhesive & Waterproofing Properties By Mixing In Proportion ( 1 Liquid: 4 Cementitious Material ) Or As Per ManufacturerS Specification For Water Proofing Layer In Water Tank Etc. 271 Supplying Mosquito Proof Net Made Of Polythene ( Netlon ) Size 75Cm. X 75Cm. For Ventilator Including Fitting, Fixing In The Best Sal Wood Frame Of 8Cm. X 5Cm. Cross Section With Necessary Wooden Batten Fixing The Assembly With Necessary Ms Clamp In Rcc Wall At The Lantern. 272 Wood Work In Door And Window Frame Fitted And Fixed In Position Complete Including A Protective Coat Of Painting At The Contact Surface Of The Frame Exluding Cost Of Concrete, Iron Butt Hinges And M.S Clamps. ( The Quantum Should Be Correted Upto Three Decimals ) .Wood Work In Door And Window Frame Fitted And Fixed In Position Complete Including A Protective Coat Of Painting At The Contact Surface Of The Frame Exluding Cost Of Concrete, Iron Butt Hinges And M.S Clamps. The Quantum Should Be Correted Upto Three Decimals. D ) Sal Local 273 Artificial Stone In Floor, Dado, Staircase Etc. With Cement Concrete ( 4:2:1 ) With Stone Chipes Laid In Panels As Directed Toping Made With Ordinary Or White Cement ( As Necy. ) & Marble Dust In Proportion ( 2:1 ) Including Smooth Finishing & Rounding Off Corners Including Rackng Out Joints Or Roughening Of Conc. Surface & Including Application Of Cement Shlurry Before Flooring Works, Using Cement @ 1.75 Kg / Sqm All Complete Including All Materials & Labour Above Heel Beam. 3 Mm Thick Toping High Polishing Grinding On This Item Is Not Permitted With Ordinary Cement. ( A ) 25 Mm Thick. ( Reservoir Inside Floor & Wall, Walk Way Floor, Cc Step, Platform Landing ) . 274 Supplying At Site Filling , Fixing , Erecting And Building In Position Where Necessary 600Mm.Wide M.S. Cat Ladder As Per Design Consisting Of 2Nos. Ismc 150, 8Mm.Thick With Necessary Base Plate Of 8Mm.Thick 100Mm.Wide M.S. Plate As Steep @ 300Mm.A / C Supported On Isa 50X50x6 , Isa 60X60x8mm.Thick Both Side As Per Requirement.900Mm.Ht. As Post On One Side / Both Side @ 1000 And Isa 45X45x6 As Horiz. Runner To Cover Side Railing Including Fabrication, Welding, Drilling Etc.As Per Drawing And Direction And Finished With Two Coats Of Synthetic Enamel Painting Over A Coat Of Primer Etc. All Complete As Per Direction Of Eic. For Cat Ladder, Railing Of Stair & Platform, Walkway Etc. E ) From 20Mtr. To 24Mtr. @ 1.5%Extra Of ( D ) 275 Supplying At Site Hoisting, Fitting, Fixing Erecting And Building In Position Where Necessary 450Mm.Wide Ladder As Per Design Consisting Of 2Nos. M.S.Plate Of 8Mm.Thick With Necessary Base Plate 60Mm Wide; And 16Mm.Dia M.S.Round Or Square Bar As Steeps Placed @ 300 C / C Including Fabrication, Welding Drilling Etc. As Per Drawing And Direction And Finished With Two Coats Of Synthetic Enamel Painting Over A Coat Of Red Lead Primer Etc. All Complete As Per Direction Of The Eic 276 Supplying, Fitting, Fixing 900 Mm High G.I. Pipe Railing For R.C.C Stair Cat Ladder Walk Way Fabrication, Erection, Welding Of 40 Mm G.I ( Non Tata Medium ) Pipe Place At Top Of Railing And 2 Nos 25 Mm Dia. G.I Pipe ( Non Tata Medium ) Placed Equally In Between Railing Top & Floor Vertical Post Of Railling Are 40 Mm Dia. G.I Pipe ( Non Tata Medium ) Placed At 900 Mm C / C . The Each End Of The Vertical Post Is Join By The 62 Mm ( 25 Mm X 6 Mm X 0.062 M Long ) Ms Flat And 150 Mm Length ( Propes Pipes ) Are Grouted In Concrete Base Of Stair, Walk Way Etc. All Complete With Supplying Of All Materials Including Hoisting Up To The Any Height Complete With 2 Coats Of Painting With Super Gloss ( Hi Gloss ) In Any Shade Except White And Black Over A Coat Of Primer Complete As Per Direction Of E.I.C. 277 Supplying Fitting And Fixing In Position Reinforced Cement Polymer Concrete Manhole Cover With Matching Frame As Per Is-12592 ( Md ) A ) Square. I ) 600 Mm X 600 Mm X 50 Kg ( Approx ) A ) 5Mt Load Bearing Capacity Round Manhole Cover Parovided With Two Nos. Lifter Hook With Machining Frame Of Size 550Mm X 65Mm ( Cover ) And 650Mm X 125Mm ( Frame ) Opening 470Mm And Wt. 90Kg. Approx. 278 Horn Gap Lighting Arrestor Complete Parts And Pin Insulators Supplying, Fitting Fixing All Complete As Per Direction Of E.I.C. 279 Plaster ( To Wall, Floor, Ceiling Etc. ) With Sand And Cement Mortar Including Rounding Off Or Chamfering Corners As Directed And Raking Out Joints Including Throating, Nosing And Drip Course, Scaffolding / Staging Where Necessary. ( Excluding Cost Of Chipping Over Concrete Surface ) With 1:4 Cement Mortar 15Mm Thick Plaster. From 16M To 20M Of Reservoir 280 With 1:4 Cement Mortar 15Mm Thick Plaster. From 20M And Above Of Reservoir 281 With 1:3 Cement Mortar 10Mm Thick Plaster Above 20 M & Above 282 Applying Exterior Grade Acrylic Primer Of Approved Quality And Brand On Plastered Or Concrete Surface Old Or New Surface To Receive Decorative Textured ( Matt Finish ) Or Smooth Finish Acrylic Exterior Emulsion Paint Including Scraping And Preparing The Surface Throughly, Complete As Per ManufacturerS Specification And As Per Direction Of The Eic.A ) One Coat Gl To 4 M 283 4M To 8 M 284 8 M To 12 M 285 12 M To 16M 286 16 M To 20 M 287 Above 20 M 288 Protective And Decorative Acrylic Exterior Emulsion Paint Of Approved Quality As Per Manufacturers Specification And As Per Direction Of Eic To Be Applied Over Acrylic Primer As Required. The Rate Includes Cost Of Material , Labour, Scaffolding, And All Other Incidental Charges But Excluding The Cost Of Primer. Two Coat. Super Protective 100% Acrylic Emalsion.Gl To 4 M 289 4M To 8 M 290 8 M To 12 M 291 12 M To 16M 292 16 M To 20 M 293 Above 20 M 294 Construction Of Different Dia Sluice Valve / Air Valve / Washout Chamber In Different Sizes For Village Road Where Light Traffic Run And For Main Road Where Heavy Traffic Run As Deptt.Approved Drawing With 25Cm Thick Brick Work ( 1:6 ) Over Cement Concrete ( 4:2:1 ) Over A Single B / F Soling Over150mm.Thick Sand Filling In Foundation Including Earth Work In Excavation And Disposal Of Excess Earth From Work Site With Rcc ( 1:1.5:3 ) Cover Slab 100Mm / 150Mm Thick Slab On Top Of Chamber With 1% Reinforcement In Rcc Cover Slab With Necessary Opening For Operation Of Valve All Complete Including Cost Of Labour & Materials As Per Departmental Dwg. [ Reinforcement Type:- Other Manufactuerers Not Specified ] 150 Mm Dia 295 100 Mm Dia. 296 Supply & Delivery Atfollowing Nominal Sizes And Classes Cidf Sluice Valve In Terms With Is 14846-2000, Inside Screw Non Rising, Stern, Flanges Faced And Drilled As Per Is 1538-1993, Spindle / Stern With Ssaisi410 As Per Is 6603-1972, Body, Bonnet, Wedge, Stuffing Box Gland Thrust Plate, Cap Inconformity With Is 210-1978, With An Amendments Order Is Specification As Stated. ( Upadhaya / Kirlosker / Kejriwal / Ivp / L & T / Vag / M & P ) Make Class-Pn 1.0 With Cap.150 Mm Dia 297 100 Mm Dia. 298 Hoisting, Erection , Placing Connecting With Pipes And Specials Cidf Pipes, Specials ) Securing With Building Specials Providing Stays, Clamps As Required Including Cost Of Staging Platform For The Work Etc.All Complete In All Respects As Per Drawing And Direction Of Eic.100 Mm Dia. 299 150 Mm Dia. 300 Laying Of Cidf / D.I Pipes With Specials, Valves Etc. In Trenches Including Excavation In All Sorts Of Soil, Moorum, Soft Rock And Refilling The Trenches After Laying & Jointing Of Pipes Etc. All Complete As Per Specification And Direction Of Eic.100 Mm Dia. 301 150 Mm Dia 302 Fitting, Fixing Duck Foot Bend Including Construction Of Cement Concrete ( 4:2:1 ) Base With Stone Chips Of Approved Grade & Quality & Including Excavation Of Earth Etc. Complete In All Respect100mm.Dia 303 150Mm.Dia 304 Hoisting, Fitting, Fixing Of Bell Mouth With Puddle Collar In Rcc Work Complete In All Respect As Per Drawing, Specification And Direction Of Eic. 100 Mm Dia. 305 150Mm.Dia 306 Making Flange Joint To Cidf Pipe, Specials, Valves Etc.With Supply Of Necessary Nuts And Bolts, Rubber Insertion Of 6Kg / M2 ( 3Mm Gauge ) And Materials Required Including Dewatering If Any Tools And Plants, Labour Cost Etc. As Per Specification And Direction Of Eic ( Nut And Bolts Shall Be Of Tata / Gkw Make ) For100 Mm Dia. 307 150Mm.Dia 308 Making Arrangement For Water Tightness Test Conforming To The Provision Laid In Is:3370 ( Pt-I ) 1956 By Filling With Water Upto Top Water Level ( Twl ) As Shown In The Drawing And As Per Direction Of Eic. ( If Water Is Supplied By The Department Rate Shall Be Reduced As Per Prevailing Departmental Rate ) 309 Disinfection & Washing The Tank And Pipe Connections Including Cleaning The Inside Of The Tank Etc Complete. 310 Neat Cement Punning About 1.5 Mm Thick In Wall, Dado, Window, Sills, Floor, Drain Etc.Note-Cement 0.152 Cu.M. Per 100 Sq.M. 311 Number Plaque Of Building ( Plaque Size Up To 225 Mm X 225 Mm ) Made Of Sand Cement Plaster ( 1 : 2 ) On Face Of Wall Or Plinth With 50 Mm Size Letters P.W.D And The Number Of The Structure Formed Thereon ( In Sunk Type ) Including Painting The Letters And The Number Complete As Per Direction. 312 Supplying And Laying Standard Four Course Bituminous Water Proofing Treatment As Per Specification Laid Down In I.S. 1346 - 1991 To Be Finished With Pea Size Gravel Including Necessary Preparatory Works Such As Shaping Mouth Of Outlets, Cutting As And Where Necessary And Refilling With Sand And Cement Mortar ( 4:1 ) Or Cement Concrete ( 1:2:4 ) With Graded Stone Chips Before Undertaking The Treatment Including Cutting Grooves In Parapet And Inserting Edge Of Felt And Mending Good Damage Complete In All Respect As Per Direction Of Engineer - In - Charge Including Cost Of All Materials And Labours And Incidental Charges But Excluding The Cost Of Cement Mortar Or Concrete Required For Levelling And Grading. ( In Sloped Roof Course Sand Of Approved Varieties Is To Be Used In Place Of Pea Size Gravels As Fourth And Final Course. ) I ) 1St And 3Rd Course With Bonding Materials Of Hot Applied Industrial Blown Type Bitumen Of Grade 85 / 25 Or 90 / 15 Conforming To I.S.702 - 1988 @ 12Kg / 10Sqm On Each Layer.Ii ) 2Nd Course With Hessian Base Self Finished Bitumen Type3r.-I Conforming To I.S. 1322-1993 ( Weighing 23Kg / 10Sqm Gross With Bitumen Content 12.10Kg / 10Sqm ) Tested Under The Provision Of I.S. 13826 - 1993 Part Vii.Iii ) 4Th Course With Washed And Clean Pea Sized Gravel Or Grit @ 0.006 Cum / Sqmb. Over Sloped Roof. 313 Supply The Following Materials For Connection Of Inlet, Outlet, Overflow And Delivery Line Of Orh Asper Departmental Drawing. A ) C.I.D.F. Pipe As Per I.S.7181 - 1986 With Letest Revision. 314 Bituminous Filer Of Approved Type In Excavation Joint Between The Shell Wall & Roof Including Finishing The Top Surface As Per ;Drawing, Specification And Direction Of Eic 315 Supplying Hoisting, Fitting Fixing Approved Type Water Level Indicator With Copper Float, Guide Pulley, Wire Boards Etc. As Per Standard Specification And Direction And Satisfaction Of Eic 316 Commissioning The R.C.C. Over Head Reservoir By Operating Of All Category Of Sluice Valves , Testing Of Hoisted Pipe Joints Including Repairing The Leakage ( S ) If Detected , Including Making Inter Connections, Flange Jointing / Lead Jointing With The Newly Laid Rising Main And Distribution Main All Complete As Per Direction Of The Eic. 317 Suppling, Fitting And Fixing M.S Clamps Door And Window Frame Made Of Flatbent Bar, End Bifurcated With Necessary Screws Etc. By Cement Concrete ( ( 1:2:4 ) As Perdirection Of Concrete Will Be Paid Separatelt. ( C ) 40Mm X 6 Mm, 125 Mm Length 318 ( A ) M.S Or W.I. Ornamental Grill Approved Design Joints Continuously Welded With M.S W.I Flats And Bars Of Windows Railing Etc. Fitted And Fixed With Bbnecessary Screws And Luge In Ground Floor. ( Add Extra @1% For Each Addl. Upto 4Th Floor And @1.25% For Each Addl. Floor Above 4Th Floor ) Grill Weighing Above 10 Kg. / Sq.M And Upto 16 Kg. / Sq. M. 319 Grill Weighing Above 16 Kg. / Sq.Mtr And Above 320 Welding In M.S Structurral Work Gas Or Electric Continuous Weld 321 Priming One Coat On Timber Or Plaster Surface With Synthetic Oil Bound Primer Of Approved Quality Includingsmoothening Surfaces By Sand Papering Etc. 322 Priming One Coat On Steelor Metalsurface With Synthetic Oil Bound Primer Of Approved Quality Includingsmoothening Surfaces By Sand Papering Etc. ( This Item Is Applicable To New Work Or Old Work When The Original Surface Has Been Exposed By Removal Of Old Paint ) 323 Painting With Best Quality Synthetic Enamel Paint Of Approved Make And Brand Including Smoothening Surface By Sand Papering Etc. Inclding Using Of Approved Putty Etc, . On The Surface, If Necessary :On Timber Or Plastered Surfacewith Super Gloss ( Hi-Gloss ) Two Coat ( With Any Shade Except White ) 324 On Steel Or Other Metal Surface: With Super Gloss ( Hi-Gloss ) Two Coat ( Any Shade Except White ) 325 A ) Earthing With 50Mm.Dia G.I. Pipe3.64Mm.Thick X 3Mtr. ( 10”-0” ) Long And L;1 X 4Swg G.I. ( Hot Dip ) Wire 4Mtr. Long 13Mm. Dia X 80Mm.Long G.I.Bolts, Double Nuts , Washer Including S&F 15Mm.Dia G.I.Pipe Protection ( 1Mtr. Long ) To Be Filled With Bitumen Partly Below Ground Level To An Av. Depth Of 3.65M Below G.L. And Restoring The Surface Duly Rammed As Per Iee Rulei ) For Soft Soil. B ) By Tata Medium G.I.Pipe. 326 Supplying Hdpe ( Materials Grade Pe-100 ) Pipes Conforming To Is 49841995 With Latest Revision & Amendments If Any With Necessary Specials ( Excluding Cost Of Cidf Valves ) Including Labour Charges For Earth Work In Excavation In Any Kind Of Soil Including Mixed Soil With Boulder, Road Sub-Grade And Aits Flank But Excluding Moorum Laterite Or Sand Stone / Hard Rock Cutting With Chisel Required Including Cutting Road Flank / Brick Pavement Etc. Without Damaging The Exisiting Telephone / Electrical Cable Line Etc. ( In Case Of Damage Of Any Type Of Cable Line By The Agency At The Time Of Execution Necessary Damage Charge As Applicable By The Respective Authority Will Have To Be Brone By The Agency At His Own Cost ) Upto The Depth ( Av. ) So As To Maintain 1.10M.Earth Cushion From Top Of The Pipe Upto G.L. Including Loading Unloading Carrying Lowering Laying Fitting Fixing Carefully Pipes, Valves And Specials With The All Types Of Jointing Materials In Trenches Maintaining Proper Levels And Alignment Jointing The Pipes And Specials By Butt Welding / Adopting Suitable Method ( But Weld Jointing With Help Of Hydraulic Tack And Trimming Machines, Hitter Etc. For Reaching At Necessary Melting Point Of Hdpe Pipe So That Joint Can Be Monolithic ) So As To Facilitate The Maintenance Of Pipe Line Locally As Per Conventional Method In Future. ( A ) Pressure Rating : Pn 6 ( I ) Laying Of Pipe Line Including Cost Of Pipe Only Excluding Cost Of Specials / Fittings Valves.B ) 90Mm ( Od ) 327 B ) 110 Mm ( Od ) 328 C ) 125Mm ( Od ) 329 C ) 140 Mm ( Od ) 330 C ) 160 Mm ( Od ) 331 Filling The Pipe Line With Water, Testing Hydraulically As Per I.S 3114-1965 ( Article-6 ) In Section Of A Length Not Exceeding 500Mtr. For Head Of Pressure As Per Specification Including Supplying Installing And Fixing All Equipments Such As Diesel Pump Set, Blank Flange, Pressure Gauge, Valve, Pressure Pump And All Other Tools And Plants Including Drilling Topping And Plugging Of Necessary Holes To Pipes, Blocking Ends Providing Temporary Thrust Block And Subsequent Blocking Of Holes And Other Jointing Materials And Dismantling And Removal Of The Same Including Disposal Of Water Etc. All Complete As Per Specification And Direction Of Eic. The Rate Is Inclusive Of Cost Of Requisite Water To Be Arranged By The Contractor ( Recovery Rate Of Water @ Rs.10.00 / M3, If Contractor Used Water From Deptt. Source ) .B ) For Upvc / Hdpe Pipea ) 90 Mm ( Od ) 332 B ) 110 Mm ( Od ) 333 C ) 125Mm ( Od ) 334 C ) 140 Mm ( Od ) 335 C ) 160 Mm ( Od ) 336 A ) For Ci / Di Pipeb ) 150 Mm Dia 337 C ) 200 Mm Dia 338 E ) 100 Mm Dia. 339 Cleaning Thoroughly The Inner Surface Of Pipe Line Including Specials And Valves By Flushing With Water And Subsequently Disinfection Of The Same Pipe Line By Flushing Again With Water Containing Bleaching Powder Resulting In Residual Chlorine Not Less Than 15Mg / Ltrs. After 24Hrs. Of Such Filling Including Laboratory Testing Of Water Samples Obtain From The Disinfested Pipe Line And Disposal Of Water From The Pipe Line After Completion Of The Work. The Rates Including Of Cost Of Requisite Water To Be Arranged By The Contractor ) ( The Rate Of Water @Rs. 10 / M3 May Be Recovered, If The Contractor Used Water From Deptt. Source ) .B ) For Upvc / Hdpe Pipea ) 90 Mm ( Od ) 340 B ) 110 Mm ( Od ) 341 C ) 125Mm ( Od ) 342 C ) 140 Mm ( Od ) 343 C ) 160 Mm ( Od ) 344 A ) For Ci / Di Pipeb ) 150 Mm Dia 345 C ) 200 Mm Dia 346 E ) 100 Mm Dia. 347 Carrying Ci / Di Pipes With Specials And Valves And Lowering Placing In Position And Laying Carefully Inside The Trenches In Proper Alignment And Gradient Etc. Including Earth Work In Excavation Of Adequate Width As Per Specification Having Min. Clear Cover From Top Of Pipe Is 1.10Mtr. Below Existing Ground Level In Any Kind Of Soil Including Mixed With Boulder, Road Sub-Grade And Its Flank, But Excluding Moorum And Laterite And Stone Etc.Without Damaging The Exisiting Telephone / Electric Cable Etc. ( In Case Of Damaged If Any Type Of Cable Line During Excecution , Necessary Damaged Charges As Applicable By The Respective Authority Will Be Borne By The Agency In His Own Cost ) Preparing The Bottom Surface For Continuous Bedding Of Pipe Line And Laying Pipes, Fitting, Fixing Specials And Valves With Bailing Out Water If Any Including Carriage Of Pipes, Specials And Valves From Local Deptt. Store Within 8Km And Back Filling The Trenches With Excavated Earth In Layers To Original Condition As Per Specification And Direction Of Eic. The Surplus Materials After Execution Of Work Are To Be Return To The Deptt. Store.N.B: I ) Any Deviation From Required Clear Cover Of 1.10Mtr., Due To Site Adverse Condition, Prior Permission Is To Be Obtained From The Eic In Exceptional Situation And Payment Will Be Made On Prorate Basis Over The Rate Of Entire Itemii ) No Payment Will Be Made Without Hydraulic Test Of The Pipe Line Either Part Or Fulliii ) The Pipes, Specials And Valves , Rubber Gasket Will Be Supplied Deptt. Free Of Cost.B ) 150 Mm Dia. 348 C ) 200 Mm Dia. 349 E ) 100 Mm Dia. 350 Making Rubber Gasket Joint To Ci / Di Pipes Maintaining Proper Alignment Level Etc. By Mechanical Arrangement With Or Without Using Mobile Cranes Where Necessary And With Help Of All Other Equipments Tools And Tackles Etc. As Required Providing Lubricants Of Approved Quality And Direction Of Eic. ( Rubber Gasket Will Be Supplied Deptt. Free Of Cost ) B ) 150 Mm Dia. 351 C ) 200 Mm Dia. 352 E ) 100 Mm Dia. 353 Construction Of Different Dia Sluice Valve / Air Valve / Washout Chamber In Different Sizes For Village Road Where Light Traffic Run And For Main Road Where Heavy Traffic Run As Deptt.Approved Drawing With 25Cm Thick Brick Work ( 1:6 ) Over Cement Concrete ( 4:2:1 ) Over A Single B / F Soling Over150mm.Thick Sand Filling In Foundation Including Earth Work In Excavation And Disposal Of Excess Earth From Work Site With Rcc ( 1:1.5:3 ) Cover Slab 100Mm / 150Mm Thick Slab On Top Of Chamber With 1% Reinforcement In Rcc Cover Slab With Necessary Opening For Operation Of Valve All Complete Including Cost Of Labour & Materials As Per Departmental Dwg. [ Reinforcement Type:- Other Manufactuerers Not Specified ] I ) 80 Mm To 150 Mm Dia Pipe 354 I ) 200 Mm Dia Pipe 355 Bituminous Pucca Road ( Approx. 450Mm Depth ) Cutting By Using Gaiti, Chisel, Hammer Etc. And Picking Uip The Withdrawing Excavated Materials And Remove The Same Within Distance Of 30Mtr. At Least All Complete For Fixing / Crossing All Dia Of Pipe Line As Per Direction Of Eic. 356 Making Barricading Of Excavation Trenches Of Road Width Upto 15Mtr. To Avoid Any Accident By Providing 75Mm Dia Bamboo Post Placed Vertically & Horizontally With The Help Of 6”Size Iron Rail As Per Direction And Satisfaction Of Eic. ( Applicable Where Critical Situation Arise And Take Up The Work As Per Direction Of Eic ) 357 Labour For Horizontal Boring Under Pucca Road Etc…………....For Laying Of Pipe.I ) Up To 150 Mm Dia. ( Ci / Di / Ac / Gi ) / 180 Mm O.D Upvc & Hdpe 358 Making Village Roadcrossing ( Average 3 M Width ) By Horizontal Augor Boring For Accmodation Of Laying Of Average 3 ( Three ) Nos 15 Mm Dia Gi Pipe For Fhtc Or As Per Direction Of Eic. 359 Ordinary Cement Concrete ( Mix 1:2:4 ) With Graded Stone Chips ( 20 Mm Nominal Size ) Excluding Shuttering And Reinforcement, If Any, In Ground Floor As Per Relevant Is Codes. ( B ) River Bazree 360 Bamboo Pile Walling Made Of 65 Mm To 75 Mm Dia. Bamboo ( In Single Line ) Driven About Half Length Into The Ground At Very Close Spacing Side By Side Including Necessary Bamboo Stays Ties Runners Etc And Lining The Exposed Portion With Sheets Made Form Cutdrums Fitted And Fixed Complete As Per Direction. 361 Supply And Delivery Of Cidf Sluice Valve ( Special Type ) Pw-1.00 Of Different Dia Make With Ci Double Flanged Non Rusting Spindle Sluice Valves Conforming To Is 14846 -2000 With Latest Emended Having Body Dome / Bonnet And Cover Of C.I.Gr-F.G 210Mtr. Spindle Of Is-6603 G.R- 12 / Gr-13 Non-Magnetic, Nuts Seat Rings Are Of Gunonetal As Per Is:318 Ltb-2 Flanges And Drilled To Is:1538 Part Iv & Vi Valves Are Suitable For Max. Working Pressure Of 10Kg / Cm2 ( Seat Test ) And Body Tested To 15Kg / Cm2. N.B: The Above Item Should Be Procured From The Reputed Manufactures As Per Deptt. Approved Vender List150 Mm Dia 362 200 Mm Dia 363 Add: Gst 18% ( + ) 364 Add: Cess 1% ( + )

Key Value

Document Fees
Refer document
EMD
INR 655080.0 /-
Tender Value
INR 3.27 Crore /-

BOQ Items

Name of Work: Execution of different works related to CHHIT BARA LAUKUTHI PWSS under JAL JEEVAN MISSION
Sl. No. Item Description
1TUBEWELL Drilling by Reverse Rotary method of drilling using 9 7/8” dia.bit for pilot bore follwed by subsequently reaming using 12 1/4” dia. ,15 " dia. and 17.5" dia. Rock Roller Bits/ Drag Bits in consolidated, semi consolidated and soft formation up to required depth including casing boring and casing lowering as required including cost of fuels and lubricants etc. as required for drilling.
2Rate for Drilling by 17.5 " dia. Bit a) From 6 Mtr. to 60 Mtr.
360 Mtr. to 90 Mtr.
490 Mtr. to 120 Mtr.
5120 Mtr. to 144 Mtr.
6Electro-logging charge.
7Supply and delivery of Washed gravels size ranging from 1.80 mm to 4.74 mm. conforming to IS 4097 : 1967.
8Site Preparation, Temporary Latrine, Placement & levelling of Rig Machine, Mast hoisting and Casing drilling (Upto 6 mtr.) Placement of Casing with all allied works necessary to commence drilling woks and wind up of all machineries after completion of Drilling.
9Transportation cost of drilling equipment and accessories rig machine etc. including cost of fuel,Lubricant & loading unloading the materials from store/stack yard /suppliers godown and unloading /stacking the same at site. (Upto 60.0 km distance)
10Lowering the tube well assembly (UPVC Casing pipe ,well pipe, strainer along with UPVC accessories) vertically in a position with proper lowering arrangement by applying necessary jointing compound including labour cost for subsequent gravel packing and machine operation cost etc
11Cost of Consumables for drilling rigs and machineries.
12Supply and delivery of UPVC pipe (CD) conforming to IS 12818:2010. (CIPET Certified) a) 250 mm dia.
13b) 200 mm dia.
14Supply and delivery of UPVC Deep Well Screen (RDS) Pipes with Ribs conforming to IS 12818:2010 .(CIPET Certified) a) 200 mm dia.
15Supply and delivery of UPVC Reducer a) 250mm x 200 mm dia.
16Supply and delivery of UPVC Cap a)200 mm dia.
17b)250 mm dia.
18Supply and delivery of M.S. Housing clamp 250 mm dia.
19Supply and delivery of M.S .Centre guide (Special Type).
20Development (Min. 8 Hr. continuous) of tube well by using suitable air compressor (Min. Capacity: 600CFM & operating Pressure 14 Bar) followed by yield testing with BHT pump (Head :45 to 50mtr.,Discharge :1100 to 1000 LPM and 25 BHP engine) all complete including To & Fro Transportation cost and Cost of fuels, lubricants & Labour etc.
21Water sample collection and chemical test including Arsenic Test.
22Protective sealing the annular space between tube well pipes & the bore by bentonite clay balls/cement slurry above the shrouded gravels (3 m. Height).
23Packing the annular space between the outsides of the housing pipe & the Bore with puddle clay balls of approved size as per direction of E.I.C. Including cost of all materials, labour complete.
24Supply and delivery of Bentonite Powder conforming to IS 6186 :1986.
25Labour for making arrangement for showing verticality test including the cost for hire charges of tools and plants, scafolding, labour etc. all complete
26TUBEWELL Drilling by Reverse Rotary method of drilling using 9 7/8” dia.bit for pilot bore follwed by subsequently reaming using 12 1/4” dia. ,15 " dia. and 17.5" dia. Rock Roller Bits/ Drag Bits in consolidated, semi consolidated and soft formation up to required depth including casing boring and casing lowering as required including cost of fuels and lubricants etc. as required for drilling.
27Rate for Drilling by 17.5 " dia. Bit a) From 6 Mtr. to 60 Mtr.
2860 Mtr. to 90 Mtr.
2990 Mtr. to 120 Mtr.
30120 Mtr. to 144 Mtr.
31Electro-logging charge.
32Supply and delivery of Washed gravels size ranging from 1.80 mm to 4.74 mm. conforming to IS 4097 : 1967.
33Site Preparation, Temporary Latrine, Placement & levelling of Rig Machine, Mast hoisting and Casing drilling (Upto 6 mtr.) Placement of Casing with all allied works necessary to commence drilling woks and wind up of all machineries after completion of Drilling.
34Transportation cost of drilling equipment and accessories rig machine etc. including cost of fuel,Lubricant & loading unloading the materials from store/stack yard /suppliers godown and unloading /stacking the same at site. (Upto 60.0 km distance)
35Lowering the tube well assembly (UPVC Casing pipe ,well pipe, strainer along with UPVC accessories) vertically in a position with proper lowering arrangement by applying necessary jointing compound including labour cost for subsequent gravel packing and machine operation cost etc
36Cost of Consumables for drilling rigs and machineries.
37Supply and delivery of UPVC pipe (CD) conforming to IS 12818:2010. (CIPET Certified) a) 250 mm dia.
38b) 200 mm dia.
39Supply and delivery of UPVC Deep Well Screen (RDS) Pipes with Ribs conforming to IS 12818:2010 .(CIPET Certified) a) 200 mm dia.
40Supply and delivery of UPVC Reducer a) 250mm x 200 mm dia.
41Supply and delivery of UPVC Cap a)200 mm dia.
42b)250 mm dia.
43Supply and delivery of M.S. Housing clamp 250 mm dia.
44Supply and delivery of M.S .Centre guide (Special Type).
45Development (Min. 8 Hr. continuous) of tube well by using suitable air compressor (Min. Capacity: 600CFM & operating Pressure 14 Bar) followed by yield testing with BHT pump (Head :45 to 50mtr.,Discharge :1100 to 1000 LPM and 25 BHP engine) all complete including To & Fro Transportation cost and Cost of fuels, lubricants & Labour etc.
46Water sample collection and chemical test including Arsenic Test.
47Protective sealing the annular space between tube well pipes & the bore by bentonite clay balls/cement slurry above the shrouded gravels (3 m. Height).
48Packing the annular space between the outsides of the housing pipe & the Bore with puddle clay balls of approved size as per direction of E.I.C. Including cost of all materials, labour complete.
49Supply and delivery of Bentonite Powder conforming to IS 6186 :1986.
50Labour for making arrangement for showing verticality test including the cost for hire charges of tools and plants, scafolding, labour etc. all complete
51RISING CUM DELIVERY MAIN Supply of CIDF & Specials as per IS 1338-1992
52Supply and delivery of CIDF Sluice valve as per I.S 14484-2000 (Upadhaya/L&T/Kirlosker/venus/Hazra)I.S.I make P.N -1.6. i) 150 mm dia.
53ii) 200 mm dia.
54iii) 250 mm dia.
55Supply of C.I. Jeffy coupling (flexible) joint complete with studtsnuts bolts, rubbon sealing reing as per I.S.Specification. i) 150 mm dia.
56ii) 200 mm dia.
57iii) 250 mm dia.
58Carrying CI/DI pipes with specials and valves and lowering placing in position and laying carefully inside the trenches in proper alignment and gradient etc. including earth work in excavation of adequate width as per specification having min. clear cover from top of pipe is 1.10mtr. below existing ground level in any kind of soil including mixed with boulder, road sub-grade and its flank,but excluding moorum and laterite and stone etc.without damaging the exisiting telephone/electric cable etc.(in case of damaged if any type of cable line during excecution , necessary damaged charges as applicable by the respective authority will be borne by the agency in his own cost) preparing the bottom surface for continuous bedding of pipe line and laying pipes, fitting, fixing specials and valves with bailing out water if any including carriage of pipes, specials and valves from local deptt. store within 8KM and back filling the trenches with excavated earth in layers to original condition as per specification and direction of EIC. The surplus materials after execution of work are to be return to the deptt. store. N.B: i) Any deviation from required clear cover of 1.10mtr., due to site adverse condition, prior permission is to be obtained from the EIC in exceptional situation and payment will be made on prorate basis over the rate of entire item ii) No payment will be made without hydraulic test of the pipe line either part or full iii) The pipes, specials and valves , rubber gasket will be supplied deptt. free of cost. b) 80 mm dia.
59150 mm dia
60200 mm dia
61250 mm dia
62Filling the pipe line with water, testing hydraulically as per I.S 3114-1965 (Article-6) in section of a length not exceeding 500mtr. for head of pressure as per specification including supplying installing and fixing all equipments such as diesel pump set, blank flange, pressure gauge, valve, pressure pump and all other tools and plants including drilling topping and plugging of necessary holes to pipes, blocking ends providing temporary thrust block and subsequent blocking of holes and other jointing materials and dismantling and removal of the same including disposal of water etc. all complete as per specification and direction of EIC. The rate is inclusive of cost of requisite water to be arranged by the contractor (Recovery rate of water @ Rs.10.00/m3, if contractor used water from deptt. source). 80 mm dia
63150 mm dia
64200 mm dia
65250 mm dia
66Cleaning thoroughly the inner surface of pipe line including specials and valves by flushing with water and subsequently disinfection of the same pipe line by flushing again with water containing bleaching powder resulting in residual chlorine not less than 15mg/ltrs. after 24hrs. of such filling including laboratory testing of water samples obtain from the disinfested pipe line and disposal of water from the pipe line after completion of the work. The rates including of cost of requisite water to be arranged by the contractor) (The rate of water @Rs. 10/m3 may be recovered, if the contractor used water from deptt. source). 80 mm dia
67150 mm dia
68200 mm dia
69250 mm dia
70Labour for horizontal boring under pucca road etc…………....for laying of pipe. i) up to 150 mm dia. (CI/DI/AC/GI)/180 mm O.D UPVC & HDPE
71Making rubber gasket joint to CI/DI pipes maintaining proper alignment level etc. by mechanical arrangement with or without using mobile cranes where necessary and with help of all other equipments tools and tackles etc. as required providing lubricants of approved quality and direction of EIC. (rubber gasket will be supplied deptt. free of cost) b) 150 mm dia.
72c) 200 mm dia.
73e) 250 mm dia.
74Making flange joint to DI/CI pipes, specials and valves where necessary with supply of required rubber insertion and nut bolts, washers etc. of approved quality and type all complete as per specification and direction of EIC (Nut and bolts shall be of TATA/GKW rate). b) 100 mm dia.
75a) 80 mm dia.
76c) 150 mm dia.
77d) 200 mm dia.
78d) 250 mm dia.
79Construction of different dia Sluice valve /Air valve /Washout chamber in different sizes for village road where light traffic run and for main road where heavy traffic run as deptt.approved drawing with 25cm thick brick work (1:6) over cement concrete (4:2:1) over a single B/F soling over150mm.thick sand filling in foundation including earth work in excavation and disposal of excess earth from work site with RCC (1:1.5:3) cover slab 100mm / 150mm thick slab on top of chamber with 1% reinforcement in RCC cover slab with necessary opening for operation of valve all complete including cost of labour & materials as per Departmental Dwg. [Reinforcement type:- Other manufactuerers not specified] i) 80 mm to 150 mm dia pipe
80i) 200 mm dia pipe
81i) 250 mm dia pipe
82Cutting DI pipe (all class & type) to required length with cutting device etc. and grinding the cutting portion with file as per direction and satisfaction of EIC. b) 150mm.dia.to 200mm.dia pipe
83Carriage of different type of departmental pipes from Divisional/Sub-divisional store to the work site by truck including loading, unloading, stacking etc. including cost of fuel, lubricant and also cost of driver, helper etc. and all other taxes and charges as applicable as per direction of EIC. upto 20 KM (above 50 km extra cost 57 Rs/km)
84HW Site P/House Earth work in excavation of foundation trenches or drains, in all sorts of soil (including mixed soil but excluding lateriatc or sandstone) including removing, spreading or stacking the spoils within a lead of 75 m. as directed. The item includes necessary trimming the sides of trenches, leveling, dressing and ramming the bottom, bailing out water as required complete. a) Depth of excavation not exceeding 1.500 mm.
85Earth work in filling in foundation trenches or plinth with good earth in layers not exceeding 150mm including watering and ramming etc. layer by layer complete. (Payment to be made on the basis of measurement of finished quantity of work) a) With earth obtained from excavation of foundation
86Filling in foundation or plinth by silver sand in layers not exceeding 150 mm as directed and consolidating the same by thorough saturation with water, ramming complete Including the Cost of supply of sand.(payment to be made on measurement of finished quantity).
87Single Brick Flat Soling of picked jhama bricks including ramming and dressing bed to proper level and 1illing joints with local sand.
88Cement concrete with 30 mm down graded shingles excluding shuttering (N.B. Variety). In ground floor a) 6:3:1 proportion
89ordinary Cement concrete mix 1:1.5:3) with graded stone chips (20 mm nominal size)exciuding shuttering and reinforcement if any, in ground floor as per relevant IS codes.River Bazree
90a) 25 mm to 30 mm shuttering without staging, in foundation
91b) 25 mm to 30 mm thick wooden shuttering as per decision & direction of E.I.C. In foundation.
92Reinforcement for reinforced concrete work in all sorts of structures including distribution bars, stirrups, binders etc initial straightening and removal of loose rust (if necessary), cutting to requisite length, hooking and bending to correct shape, placing in proper position and binding with 16 gauge black annealed wire at every intersection, complete as per drawing and direction. (a) For works in foundation and upto roof of ground floor/upto 4 m (i) other that Tor steel/Mild SteelSAIL/ TATA/ RINL
93Brick work with Ist class bricks in cement mortar (1:6) (a) In Foundation and plinth
94b) In superstucture, ground floor.
95Artificial stone in floor, itado, staircase etc. with cement concrete (1:2:4) with stone chips, Iaid in panels as directed with topping made with ordinary or white cement (as necessary)and marble dust in proportion (1:2) including smooth finishing and rounding off corners including raking out joints or roughening of concrete surface and application of cement slurry betore flooring works using cement 175 kg/sq.m all complete including all materials and labour.In ground floor. (i)35 mm. Thick
96Wood work in door and window frame fitted and fixed in position complete including a protective coat of painting at the contact surface of the frame exluding cost of concrete,iron Butt Himges and M.S clamps.(The quantum should be correted upto three decimals). a) Sal: Siliguri
97Supplying, fitting and fixing M.S. clamps for door and window frame made of flat bent bar,end bifurcated with necessary screws etc. by cement concrete(1:2:4) as per direction. (Costof concrete will be paid separately) (i) 40mm x bmm, 200mm Length
98Supplyof Fan hook.
99Plaster (to wall, floor, ceiling etc.) with sand and cement mortar including rounding off or chamfering corners as directed and raking out joints including throating, nosing and drip course, scaffolding/staging where necessary (Ground floor).[Excluding cost of chipping over concrete surface. i) with 1:6 cement mortar a) 20 mm thick plaster
100b) 15 mm thick plaster
101ii) With 1:4 cement mortar c) 10 mm thick plaster
102Neat cement punning about 1.5 mm thick in wall, dado, window sills, floor, drains etc
103Applying decorative cement based paint of approved quality after preparing the surface including scraping the same thoroughly (plastered or concrete surface) as per manufacturer"s specification. In Ground floor (i) One coat on new surface
104ii) Two coats.
105Protective and Decorative Acrylic exterior emulsion paint of approved quality, as per manufacturer"s specification and as per direction of EIC to be applied over acrylic primer as required. The rate includes cost of material, labour, scaffolding and all incidental charges but excluding the cost of primer. a) In Ground floor (Two Coat) (i) Normal Acrylic Emulsion
106a) Priming one coat on timber or plastered surface with synthetic oil bound primer of approved quality including smoothening surfaces by sand papering etc
107(b) Priming one coat on steel or other metal surface with synthetic oil bound primer of approved quality including smoothening surfaces by sand papering etc.
108Painting with best quality synthetic enamel paint of approved make and brand including smoothening.surtace by sand papering etc. including using of approved putty etc. on the surface, if necessary.(a) On timber or plastered surface With super gloss (hi-gloss). Two coat (with any shade except white
109b) On Steel surface i) One coat (with any shade except white
110Panel shutters of door and window, asper design (each panel consisting of single plank without joint), including fitting and fixing the same in position but excluding the cost of hinge and other fittings. in ground floor. (i)35 mm thick shutters with 19 mm thick panel of size 30 to 45 cm. a) Sishu,Gamar,Champ,Bhola,Mogra,Hallak.
111Glazed shutter of door ,windows, fan light clerestory window etc. As per designe (with ordinary glassof 7.4 kg/sq.m. 3 mm thick) fitted with putty bed and teak wood bead cost of hings and other fittings and fixing shutter in position but excluding the cost of hinges and other fittings .cost of glass putty wooded beads etc will be separately. 35 mm thick shutter . a) Sishu,Gamar,Champ,Bhola,Mogra,Hallak.
112SIpplyng best Indian sheet glass panes set in putty and fited and fixrd witlh ails and putty Conmplete. (In all floors for internal wall& upto 6 nm height for external wall. (i) 4 mm thick
113MS.or W.I Ornamental grill of approved design joints continuously welded with M.S.W.Flats and bars of windows, railing etc. fitted and fixed with necessary screws and lugs in Rround floor. (i) Gril weighing above 10 Kt./sq mtr and up to 16 Kg./sq, mtr.
114i) 300 mm.Iron hasp bolt of approved quality fitted and fixed complete (oxidised) with 16mm dia rod with centre bolt and round fitting.
115(i)150 mm x5.5 mm .Iron door handle of approved quality fitted and fixed complete:
116(ii) 100 mm x 5 mm.
117i) Sal Siliguri.a)with 75 mm iron Butt-hingeSupplying, fitting and fixing hinge cleat in position excluding the cost hinge and other fittings.
118i)Sal: Siliguri.b) with 50 mm iron Butt-hinge
119Iron butt hinges of approved quality fitted and fixed with steel screws, with ISI mark.i) 50 mm. X 37mm. X 1.50mm
120(i) 75mm. X 40mm. X 1.12mm.
121(i) 100mm. X 50mm. X 1.25mm
122Iron socket bolt of approved quality fitted and fixed complete.a) 100mm long x 10mm dia bolt.
123b) 150mm long x 10mm dia bolt.
124Chalmp for fan light fitted & fixed complete
125Precast pierced concrete jally work as per design and manufacturer"s specification including moulding etc. with stone chips and necessary reinforcement shuttèring complete including fitting, fixing in position in all floors. (a) 37.5 mm thick panels
126Supplying P.V.C. water storage tank of approved quality with closed top with lid (Black) -Multilayer (a) 500 litre capacity.
127Labour for hoisting plastic water storage tank
128Supplying, fitting and fixing G.I. pipes of TATA make with all necessary accessories, specials viz. socket, bend, tee, union, cross, elbo, nipple, longscrew, reduing socket, reducing tee short piece etc. fitted with holder bats clamps, including cutting pipes, making threads fitting, fixing etc. complete in all respect including cost of all nece[sarý fittings required,jointing materials and two coats of painting with approved paint in any position above ground.(Payment will be made on the centre line measurements of total pipe line includingall pecials.No separate payment will be made for accesories,specials.( Payment for painting will be made seperately) (i) 25 mm dia. medium quality
129(ii)15 mm dia. medium quality
130Labour for punching hole in plastic water storage tank upto 50 mm dia.
131Supplying, titting and fixing gunmetal wheel valve of approved brand and make tested to 21 kg per sq. cm. (for water lines only). i)25 mm dia.
132ii) 20 mm dia.
133Supplying, fitting and fixing alloy iron with brass spindle bib cock/ stop cock of approved brand and make, spray painted and tested to 21 kg per sq. cm. i) 15 mm dia
134Supply of UPVC pipes & fittings etc. conforming to IS-13592-1992 i) Door Tee 110 mm
135ii) Vent Cowl 110 mm
136(ii) Door Bend (T.S.) 110 mm
137Supply of UPVC pipes (B Type) & fittings conforming to IS-13592-1992 a) Single Socket 3 meter length. (i)110 mm .
138Orissa pattern water closet in white glazed vitreous chinaware of approved make in position . (i) 530 mm x 410 mm.
139Supplying ,fitting ,fixing cast iron "P" OR "S" trap conforming to IS: 3989/1970/ and 1729/1964 incl. Lead caulked joints and painting two coats to exposed surface .(painting to be separately). a) ""S "" trap i)100 mm dia .
140Supplying ,fitting ,fixing, 10 liter P.V.C. Low-down cistern conforming to I.S specification with P.V.C. Fittings complete.C.I. Brackets incl. Two coats of painting to bracket etc. i)White
141Construction of inspection chamber measure 600mm X 600mm X upto 600mm(depth) with250 mm thick 1st class brick wWk In cement mortr (1:4) on all sides, bottom of the pit conuntng of 100 mm thick cement concrete(1:3:6) with stone chips over a layer of jhama brick flat soling15 mm thick (1:4) cenent plster to inSide walls. a)with bazree (N.B VARITY)
142Constrution of septic tank of differont apacities as per approved drawng wilh 1st class bCk work m cement mortar (l:4) includng two 560 mm dia. R.C.C. manhole cover(heavy type)ot approved make supplod, Iitted and fNed in the 100m thick R.C.C(I:1.5:3) top slab with necessary fittingS, 20mm thick cement plaster (4 :1)with neat cement finish to the internal surfaces and 15 mm thick cement plaster (4 :1) to outside wall upto 200 mm below 6. floor tunished with 25 mm thick grey artificat A) For 10 users i) With Baztee[N.B Varitv]
143Construction of circular soak well 2.5 metre deep in all types of sandy soils with dry brick work upto 1.6 metre from the bottom having 150 mm intermediate ceiment brick work (1:4)band all round and cement brick work (1:4) upto 0.90 metre from top with 20mm thick cement plastering (1:4) to inside face upto the depth of cement brick. With 250 mm thick dry brick work and 250 mm thick cement brick work (1:6) and 1.00 m inside dia.
144125 mm. thick brick work with 1st class bricks in cement mortar (1:4) in ground floor
145Supplying. fitting and fixing fibre reinforced polymer (FRP) Composite door frame as per approved section with glass fibre reinforced plastic mouided skins and a special sandwich core, so as to impart monolitaheic composite structure as per approved technology Department of Science and Technology (DST) to safisty IS: 4020 door testing performanc (i) 66 mm x 90 mm
146Supplying fitting fixing best quality Digital printed ceramic tiles in colour decorative in wall 1& ftloor to match with.Complete.
147HW Site BOUNDARY WALL Earth work in excavation of foundation trenches or drains, in all sorts of soil (including mixed soil but excluding lateriatc or sandstone) including removing, spreading or stacking the spoils within a lead of 75 m. as directed. The item includes necessary trimming the sides of trenches, leveling, dressing and ramming the bottom, bailing out water as required complete. a) Depth of excavation not exceeding 1.500 mm.
148Earth work in filling in foundation trenches or plinth with good earth , in layers not exceeding 150mm. Including watering and ramming etc. Layer by layer complete (Payment to be made on the basis of measurement of finished quantity of work ) A)With earth obtained from excavation of foundation.
149Cement concrete (1:3:6) with 30 mm down graded excluding shuttering. a) 6:3:1 Proportion.
150Ordinary cement concrete M-20(mix 3:1:5;1)with graded stone chips(20 mm down) excluding shuttering and reinforcement .if any ,in ground floor, as per I.S. 456-2000. i)River Bozree.
151Reinforcement for reinforced concrete work in all sorts of structures including distribution bars, stirrups, binders etc initial straightening and removal of loose rust (if necessary), cutting to requisite length, hooking and bending to correct shape, placing in proper position and binding with 16 gauge black annealed wire at every intersection, complete as per drawing and direction. (a) For works in foundation and upto roof of ground floor/upto 4 m (i) other that Tor steel/Mild SteelSAIL/ TATA/ RINL
152Hire and labour charges for shuttering with centreing and necessary staging up to 4m using approved stout props and thick hard wood planks of approved thickness with required bracing for concrete slab . beams ,columns, lintels curved or straight including fitting fixing and striking out of Completion of works (up to roof of ground floor). a) 25 mm to 30 mm thick shuttering with out staging and foundation etc,
153b) )25 mm to 30 mm thick wooden shutter as per decision & direction of Engineer-in-charge.
154Plaster (to wall,floor ,ceiling etc,) with sand and cement mortar including rounding off chamfering corners as directed and raking out joints or roughening of concrete surface including throating ,nosing and drip course where necessary (ground floor).. With cement mortar( 6:1.).15 mm thick plaster.
155With cement mortar( 6:1.).20 mm thick plaster.
156With cement mortar(4:1) 10 mm thick.
157Neat Cement punning about 1.5mm thick in wall ,dado , window, sills floor drain etc,
158Priming one coat on timber plastered or on steel or other metal surface with synthetic enamel / oil bound primer of approved quality including smoothening surface by sand preparingetc On timber .
159Painting with best quality synthetic enamel paints of approved / make and brand including smoothening surface by sand preparing etc, including using of approved. Putty etc, on the surface of necy. i)On timber or plastered surface. With super gloss (hi-gloss). a)One coats (with any shade except white )
160Protective decorative Acrylic exterior emulsion paint of approved quality as per manufacturer’s specification and as per direction of EIC to be applied over acrylic primer as required . The rate includes cost of materials , labour , scaffolding and all incidental charges but excludingthe Cost of primer. a) Normal Acrylic emulsion. (i) Two coat
161Earth work in filling compound ,Tank , low sand ditches etc, good earth, in layer not exceeding 250mm including breaking clods & consolidating the same by ramming and dressing complete etc. layer by layercomplete i) With carried earth arrangement by the contractor within a radius of 3km including the cost of carriage but not exceeding 5km
162M.S. & WI Ornamental grill of approved design joints continuously welded with MS.WI. flats and bars of windows railing etc. fitted and fixed with necessary screws andlugs in ground floor. (i) Grill weighing above 10kg/sq.m. and up to16kg/sqm.
163125 mm thick brick work with 1st class bricks in cement mortar (1:4) with1st class brick in all floor.
1642nd Site P/House Earth work in excavation of foundation trenches or drains or septic tank soak well etc. in all sorts of soil (including mixed soil but excluding latarite or sand stone) including removing spreading or stack-ingthespoilswithinaleadof75m.asdirected.Theitem includesnecessarytrimmingthesidesofthetrenches,leveling dressing and ramming the bottom, bailing or pumping out water etc. asrequiredcomplete. Depthofexcavationnotexceeding1.5mtr. but not requiring shoring
165Earth work in filling in foundation trenches or plinth with good earth in layers not exceeding 15cm. Including watering and ramming etc. layer by layer complete. (Payment to be made on basis of measurementof finishedquantity ofwork) A. with earth obtained from Excavation of Foundation
166Filling in foundation or plinth by fine sand in layers not exceeding 150 mm as directed & consolidating same by throughsaturationwithwaterandramming completeincluding the costofsupplyofsand.(Paymenttobemadeonthebasisof measurement of finished quantity of work.) (a) By fine sand.
167Singlebrickflatsolingofpicked jhamabricksincludingramming&dressingbedtoproperlevel& fillingjointswithpowderedearthorlocalsandincludingcostof sand etc complete as per direction & specification.
168Cement concrete with 30 mm down graded shinglesexcluding shuttering (N.B. Variety). In ground floor a) 6:3:1 proportion.
169OrdinaryCementconcrete(mix1:1.5:3)withgradedstonechips(20mmnominalsize) excluding shuttering and reinforcement if any, in ground floor as per relevant IS codes. (i) River Bazree
170Hire and labour charges for shuttering with centering and necessary staging upto 4 m. using approvedstoutpropsandthickhardwoodplanksofapprovedthicknesswithrequired bracing for concrete slabs, beams, columns, lintels curved or straight including fitting, fixing and striking out after completion of works (upto roof of ground floor). a) 25 mm to 30 mm shuttering without staging in foundation.
171b) 25 mmto30 mmthick wooden shuttering asper decision& ddirectionoftheE.I.C. in foundation.
172Reinforcement for reinforced concrete work in all sorts of structures including distribution bars, stirrups, binders etc initial straightening and removal of loose rust (if necessary), cutting to requisite length, hooking and bending to correct shape, placing in proper position and binding with 16 gauge black annealed wire at every intersection, complete as per drawing and direction. (a) For works in foundation and upto roof of ground floor/upto 4 m (i) other that Tor steel/Mild SteelSAIL/ TATA/ RINL
173Brick work with 1st class bricks in cement mortar (1:6) (a) In foundation and plinth
174(b) In superstructure, ground floor
175Artificial stone in floor, dado, staircase etc. with cement concrete (1:2:4) with stone chips, laid in panels as directed with topping made with ordinary or white cement (as necessary) andmarbledustinproportion(1:2)includingsmoothfinishingandroundingoffcorners includingrakingoutjointsorrougheningofconcretesurfaceandapplicationofcement slurrybeforeflooringworksusingcement@1.75kg/sq.mallcompleteincludingall materials and labour. In ground floor. (i) 35 mm. thick
176Woodworkindoorandwindowframefittedandfixedinpositioncompleteincludinga protective coatofpainting atthe contactsurface ofthe frameexluding costofconcrete, Iron Butt Hinges and M.S clamps. (The quantum should be correted upto three decimals). a) Sal : Siliguri
177Supplying, fitting and fixing M.S. clamps for door and window frame made of flat bent bar, end bifurcated with necessary screws etc. by cement concrete(1:2:4) as per direction. (Cost of concrete will be paid separately) (i) 40mm X 6mm, 200mm Length
178Plaster (to wall, floor, ceiling etc.) with sand and cement mortar including rounding off or chamferingcornersasdirectedandrakingoutjointsincludingthroating,nosingand drip course, scaffolding/staging where necessary (Ground floor).[Excluding cost of chipping over concrete surface (i) With 1:6 cement mortar (a) 20 mm thick plaster
179(b) 15 mm thick plaster
180(ii) With 1:4 cement mortar (a) 10 mm thick plaster
181Neat cement punning about 1.5 mm thick in wall, dado, window sills, floor, drains etc.
182Applyingdecorativecementbasedpaintofapprovedqualityafterpreparingthesurface includingscrapingthesamethoroughly(plasteredorconcretesurface)asper manufacturer"s specification. a) In Ground floor: (i) Two coats.
183ProtectiveandDecorativeAcrylicexterioremulsionpaintofapprovedquality,asper manufacturer"s specification and as per direction of EIC to be applied over acrylic primer as required. The rateincludes costofmaterial,labour,scaffoldingand allincidental charges but excluding the cost of primer. a) In Ground floor (Two Coat) (i) Normal Acrylic Emulsion
184(a)Primingonecoatontimberorplasteredsurfacewithsyntheticoilboundprimerof approved quality including smoothening surfaces by sand papering etc.
185(b)Primingonecoatonsteelorothermetalsurfacewithsyntheticoilboundprimerof approved quality including smoothening surfaces by sand papering etc.
186Paintingwithbestqualitysyntheticenamelpaintofapprovedmakeandbrandincluding smootheningsurfaceby sandpaperingetc.includingusingofapproved puttyetc.onthe surface, if necessary : (a) On timber or plastered surface : With super gloss (hi-gloss) - i) Two coat (with any shade except white)
187(b) On Steel surface : With super gloss (hi-gloss) - i) One coat (with any shade except white)
188Panelshuttersofdoorandwindow,asperdesign(eachpanelconsistingofsingleplank withoutjoint),includingfittingandfixingthesameinpositionbutexcludingthecostof hinge and other fittings. In ground floor. (i) 35mm thick shutters with 19mm thick panel of size 30to 45 Cm. a) Sishu, Gamar, Champ,Badam,Bhola, Mogra, Hallak.
189Glazedshuttersofdoors,windows,fanlight,clerestorywindowsetc.as perdesign (with ordinary glass of 7.4kg./sq.m. 3mm. Thick) fitted with putty bed and teak wood bead and nailsincludingfittingandfixingshutterinpositionbutexcludingthecostofhingesand other fittings. cost of glass, putty, wooded beads etc.will be paid separately. (i) 35mm thick shutters. a) Sishu, Gamar, Champ,Badam,Bhola, Mogra, Hallak.
190Supplying best Indian sheet glass panes set in putty and fitted and fixed with nails and putty complete. (In all floors for internal wall & upto 6 m height for external wall) (i) 4 mm thick
191M.S.or W.I. Ornamental grill of approved design joints continuously welded with M.S, W.I. Flatsand barsofwindows,railingetc.fittedand fixedwithnecessaryscrewsandlugsin ground floor. i) Grill weighing above 10 Kg./sq.mtr and up to 16 Kg./sq. mtr.
192Iron hasp bolt of approved quality fitted and fixed complete (oxidised) with 16mm dia rod with centre bolt and round fitting. i) 300 mm
193Iron door handle of approved quality fitted and fixed complete: (i) 150mm x 5.5mm.
194(ii) 100mm x 5mm.
195Supplying,fittingandfixinghingecleatinpositionexcludingthecosthingeandother fiffitngs. a) with 75mm iron Butt-hinge i) Sal : Siliguri.
196b) with 50mm iron Butt-hinge i) Sal : Siliguri.
197Iron butt hinges of approved quality fitted and fixed with steel screws, with ISI mark. (i) 50mm. X 37mm. X 1.50mm.
198(ii) 75mm. X 40mm. X 1.12mm.
199(iii) 100mm. X 50mm. X 1.25mm.
200Iron socket bolt of approved quality fitted and fixed complete. (a) 100mm long x 10mm dia bolt.
201(b) 150mm long x 10mm dia bolt.
202Cord for fan light fitted & fixed complete.
203Precast pierced concrete jally work as per design and manufacturer"s specification including moulding etc. with stone chips and necessary reinforcement shuttering complete including fitting, fixing in position in all floors. (a) 37.5 mm thick panels
204SupplyingP.V.C.waterstoragetankofapproved qualitywithclosed topwith lid(Black) - Multilayer (a) 500 litre capacity
205Labour for hoisting plastic water storage tank. (i) Upto 1500 litre capacity. (a) Upto 1st story from G.L.
206Supplying, fitting and fixing G.I. pipes of TATA make with all necessary accessories, specials viz. socket, bend, tee, union, cross, elbo, nipple, longscrew, reducing socket, reducing tee, shortpieceetc.fittedwithholderbatsclamps,includingcuttingpipes,makingthreads, fitting, fixing etc. complete in all respect including cost of all necessary fittings as required,jointing materialsand twocoatsofpainting with approved paint inany position above ground. (Payment will be made on the centre line measurements of totalpipe line including all specials. No separate payment will be made for accesories, specials. Payment for painting will be made seperately) (i) 20 mm dia. medium quality.
207(ii) 15 mm dia. medium quality
208Labour for punching hole in plastic water storage tank upto 50 mm dia.
209Supplying, fitting and fixing gunmetal wheel valve of approved brand and make tested to 21 kg per sq. cm. (for water lines only). (i) 15 mm dia.
210(ii) 20 mm dia.
211Supplying,fittingand fixing alloyironwithbrassspindlebib cock/stopcockofapproved brand and make, spray painted and tested to 21 kg per sq. cm. (i) 15 mm dia.
212Supply of UPVC pipes & fittings conforming to IS-13592-1992 (i) Door Tee , a) 110 mm
213(ii) Vent Cowl , a) 110 mm
214(iii) Door Bend (T.S.), a) 110 mm
215Supply of UPVC pipes (B Type) & fittings conforming to IS-13592-1992 (A) (i) Single Socketed 3 Meter Length a) 110 mm
216Supplying, fitting and fixing Orissa pattern water closet in white glazed vitreous chinaware of approved make in position complete excluding "P" or "S" trap (excluding cost of concrete for fixing). (i) 530 mm X 410 mm
217Supplying,fitting and fixing cast iron "P" or "S" trap conformimg to I.S. 3989 / 1970 and 1729 / 1964 including lead caulked joints and painting two coats to the exposed surface. (Painting to be paid seperately). A) "S" Trap i) 100 mm dia
218Supplying, fitting and fixing 10 litre P.V.C. low-down cistern conforming to I.S. specification with P.V.C. fittings complete,C.I. brackets including two coats of painting to bracket etc i) White
219ConstructingInspectionpitofinsidemeasurement600 mmX600mmXupto600mm (depth) with 250 mm thick 1st. class brick work in cement mortar (1:4) on all sides, bottom of the pit consisting of 100 mm thick cement concrete (1:3:6) with stone chips over a layer ofjhamabrickflatsoling,15mmthick(1:4)cementplastertoinsidewallsandout-side wallsuptoG.L.and20mm.thick(1:4)plastertobottomofthepit,providingnecessary invert with cement concrete (1:3:6) with stone chips as per direction, neat cement finishing toentireinternalsurfaces,topofthe pitcovered with100 mmthick R.C.C.slab (1:1.5:3) withstonechipsandnecessaryreinforcementsupto1%andshutteringincluding6mm thickcementplaster(1:4)inallexternalsurfaces ofthe slaband one560 mmdia. R.C.C. manholecoverofapprovedmakesupplied,fittedandfixedintheslabwithnecessary fittings,necessaryearthworkinexcavationinallsortsofsoil,fillingsidesofthepitwith earthand removingspoilsafterworkcompleteinallrespectwith allcostsoflabourand materials. ii) With Bazree (N.B Variety) (SAIL/TATA/RINL)
220Construction ofseptictank of different capacities asper approved drawing with1st class brick work in cement mortar (1:4) including two 560 mm dia. R.C.C. manhole cover(heavy type)ofapprovedmakesupplied,fittedandfixedinthe100mmthickR.C.C(1:1.5:3)top slab with necessary fittings, 20mm thick cement plaster(4 : 1) with neat cement finish to the internal surfaces and 15 mm thick cement plaster (4 : 1) to outside wall upto 200 mm below G.L floor finishedwith 25mm thick grey artificialstone over 100 mmthick R.C.C(1:1.5:3)bottom slabincludingsupplying,fittingandfixingallnecessryspecials, fittings, S.W. tees, C.I. foot rest etc. including excavation earth in allsorts ofsoil, shoring, bailingoutand pumpingoutwaterasnecessary,ramming,dressingthebedand fefilling the sides of the tanks with earth, removing spoils, filling up the chamber with clear water, removing foreign materials from the chamber and including constructing attached inspection pit as per approved drawing and con in all respectwith allcosts oflabour and materials.aterials. With 250 mmthick drybrick workand 250mmthickcement brickwork (1:6)and 1.00m inside dia. by weight of cement with all costs of labour and materials. (i) For 10 users A) With Bazree(N.B Varity)(SAIL/TATA/RINL)
221Construction of circular soak well 2.5 metre deep in all types of sandy soils with dry brick workupto1.6metrefromthebottomhaving150mmintermediatecementbrickwork (1:4)bandallroundandcementbrickwork(1:4)upto0.90metrefromtopwith20mm thickcementplastering(1:4)toinsidefaceuptothedepthofcementbrickwork,15mm thickcementplaster(1:4)onouterfacefromtopofthewelluptoG.L.and6mmthick cement plaster (1:4) on top of the R.C.C. cover slab including filling bottom 1.00 metre of inside of the well with brick metal (50 mm to 63 mm size) including R.C.C. cover slab of 100 mmthickwithcementconc(1:1.5:3)withstonechipswithnecessaryreinforcementand shuttering including one 560 mm dia. R.C.C. manhole cover (heavy type)of approved make supplied,fittedandfixedinthecoverslabwithnecessaryfittings,makingnacessary arrangementsforpipeconnections,excavationofwellincludingshoring,dewateringand removing the exess earth from the premisesas per direction completein allrespect with all costs of labour and materials. With 250 mmthick drybrick workand 250mmthickcement brickwork (1:6)and 1.00m inside dia. a) Other than SAIL/TATA/RINL)
222125 mm. thick brick work with 1st class bricks in cement mortar (1:4) in ground floor.
223Carriage of different type of departmental pipes from Divisional/Sub-divisional store to the work site by truck including loading, unloading, stacking etc. including cost of fuel, lubricant and also cost of driver, helper etc. and all other taxes and charges as applicable as per direction of EIC a) Above 10 Km upto 20 Km 250 mm DI Pipe
22416 mm dia. 1mtr long Fan Hook
225Supplying fitting fixing best quality Digital printed ceramic tiles in colour decorative in wall 1& ftloor to match with.Complete.
2262nd Site B/Wall Earth work in excavation of foundation trenches or drains, in all sorts of soil (including mixed soil but excluding laterite or sandstone) including removing, spreading or stacking the spoils within a lead of 75 m. as directed. The item includes necessary trimming the sides of trenches, levelling, dressing and ramming the bottom, bailing out water as required complete. a) Depth of excavation not exceeding 1,500 mm
227Earth work in filling in foundation trenches or plinth with good earth, in layers not exceeding 150 mm. including watering and ramming etc. layer by layer complete. (Payment to be made on the basis of measurement of finished quantity of work) (a) With earth obtained from excavation of foundation.
228Earth work in filling in foundation trenches or plinth with good earth, in layers not exceeding 150 mm. including watering and ramming etc. layer by layer complete. (Payment to be made on the basis of measurement of finished quantity of work) c) (iii) With carried earth arranged by the contractor within a radius exceeding 3 km. but not exceeding 5 km. including the cost of carried earth.
229(II) Cement concrete with 30 mm down graded shingles excluding shuttering. N.B. Variety (1:3:6)
230Ordinary Cement concrete (mix 1:2:4) with graded stone chips (20 mm nominal size) excluding shuttering and reinforcement,if any, in ground floor as per relevant IS codes. (a ) River bazree
231Ordinary Cement concrete (mix 1:1.5:3) with graded stone chips (20 mm nominal size) excluding shuttering and reinforcement if any, in ground floor as per relevant IS codes. (i ) River Bazree
232Reinforcement for reinforced concrete work in all sorts of structures including distribution bars, stirrups, binders etc initial straightening and removal of loose rust (if necessary), cutting to requisite length, hooking and bending to correct shape, placing in proper position and binding with 16 gauge black annealed wire at every intersection, complete as per drawing and direction. (a) For works in foundation and upto roof of ground floor/upto 4 m (i) other that Tor steel/Mild SteelSAIL/ TATA/ RINL
233Hire and labour charges for shuttering with centering and necessary staging upto 4 m. using approved stout props and thick hard wood planks of approved thickness with required bracing for concrete slabs, beams, columns, lintels curved or straight including fitting, fixing and striking out after completion of works (upto roof of ground floor). f) 25 mm to 30 mm shuttering without staging in foundation
234b) )25 mm to 30 mm thick wooden shutter as per decision & direction of Engineer-in-charge.
235125 mm. thick brick work with 1st class bricks in cement mortar (1:4) in ground floor.
236Plaster (to wall, floor, ceiling etc.) with sand and cement mortar including rounding off or chamfering corners as directed and raking out joints including throating, nosing and drip course, affolding/staging where necessary (Ground floor).[Excluding cost of chipping over concrete surface] (i) With 1:4 cement mortar a) 10 mm thick plaster
237(ii) With 1:6 cement mortar (b) 15 mm thick plaster
238(a) M.S.or W.I. Ornamental grill of approved design joints continuously welded with M.S, W.I. Flats and bars of windows, railing etc. fitted and fixed with necessary screws and lugs in ground floor. (Add extra @ 1% for each addl. floor upto 4th floor and @ 1.25% for each addl. floor above 4th floor) (i) Grill weighing above 10 Kg./sq.mtr and up to 16 Kg./sq. mtr.
239Neat cement punning about 1.5mm thick in wall, dado, window sill, floor etc.
240Priming one coat on timber plastered or on steel or other metal surface with synthetic enamel / oil bound primer of approved quality including smoothening surface by sand preparingetc On timber .
241Painting with best quality synthetic enamel paints of approved / make and brand including smoothening surface by sand preparing etc, including using of approved. Putty etc, on the surface of necy. i)On timber or plastered surface. With super gloss (hi-gloss). a)One coats (with any shade except white )
242Protective decorative Acrylic exterior emulsion paint of approved quality as per manufacturer’s specification and as per direction of EIC to be applied over acrylic primer as required . The rate includes cost of materials , labour , scaffolding and all incidental charges but excludingthe Cost of primer. a) Normal Acrylic emulsion. (i) Two coat
243FHTC Providing FHTC from the existing CI/DI/Upvc/HDPE/GI/AC distribution pipeline by installing 10 mm dia NB Gun metal Ferrule conforming to IS 2692:1989 with latest amendments on thesaid pipeline and all othersaccessories like saddle piece of require size to fit the existing distribution pipeline ,specials, nut & bolts rubber sheet , washer etc.and laying15 mm NB PVC (schedule 80)/ 20 mm OD HDPE (PE 100 , PN16 )/ 20 mm OD PPR-C (Class -SDR 7.4/PN16) pipes uptorequired length with all necessary specials1.0 metre below the ground connecting ferrule including cutting trenches in all sorts of soil and filling up trenches as per directionsof the Engineer-in-charge and upto a point just inside the premises of the house hold or as directed by EIC. Supply and installation of a l5mm dia. alloy ironBib Cock (tested to 2t Kg/cm2) above 1.0 Mtr. frorn ground, an alloy stop cock of 15 mm diawith brass spindle (tested ta 21 Kg/cm2) to be fitted in a position as directed by E.I.C. G.l pipe of TATA make (mediurn duty) of 2 metre length with all necessary specials to continue from the end of the PVC/HDPE/PPR-C pipe and upto 1.0 m above ground within the premises of household. Note: 1. PVC pipe shall of schedule 80(medium duty) conforming to ASTMD -1785 and threaded to match with Gl Pipes as per IS : 1239 (Part - I). 2. PPR-C (Poly propylene Randam copolymer) pipe shall be 3-layer confirming to IS :15801 UV stabilised & anti-microbiol fusion welded, having thermal stabitity for hot & cold water supply including all PP-R plain & brass threaded porypropylene random /fittings . 3. Rate is exclusive of supply and deliveryof10 mm NB gun-metal Ferrule. supply & laying of 15mm NB PVC (schedule 80)/20mm OD HDPE (PE 100,PN16)/20 mm OD PPR-C (Class -SDR7.4/PN19) pipes. b) Above 10 m upto 20 m length
244100 OHR Earth work in excavation of foundation trenches or drains or septic tank soak well etc. in all sorts of soil (including mixed soilbut excluding latarite or sand stone) including removing spreading or stack- ing the spoils within a lead of 75m. as directed. The item includes necessary trimming the sides of the trenches, leveling dressing and ramming the bottom, bailing or pumping out water etc. as required complete.
245Depth of excavation not exceeding 1.5 mtr. but not requiring shoring
246Beyond 1.5 mtr. upto 3.0 mtr.but not requiring shoring
247Filling in foundation or plinth by fine sand in layers not exceeding 150 mm as directed & consolidating same by through saturation with water and ramming complete including the cost of supply of sand. (Payment to be made on the basis of measurement of finished quantity of work.)(a) By fine sand.
248Earth work in filling in foundation trenches or plinth with good earth in layers not exceeding 15cm. Including watering and ramming etc. layer by layer complete. (Payment to be made on basis of measurement of finished quantity of work)
249Single brick flat soling of picked jhama bricks including ramming & dressing bed to proper level & filling joints with powdered earth or local sand including cost of sand etc complete as per direction & specification.
250Oridinary Cement Concrete M-15 (Mix 1:2:4) with graded stone chips (20 mm.down) excluding shuttering and reinforcement, if any, in ground floor as per relevent IS code 456-2000. From …...concidaring 73 Km.a) Pakur / (Up to ground level).
251Controled cement concrete with well graded stone chips (20 mm nominal size) excluding shuttering & reinforcement with complete design of concrete as per [ISI : 456 and relevant special publication. Submission of job mix formula after preliminary mix design after testing of concrete cube as per direction of the EIC. consumption of cement will not be less than 300kg of cement with super plasticiser per cum. of controlled conc. but actual consumption will be determined on the basis of preliminary test & job mix formuta. In ground floor and foundation.[Using concrete mixture] M 25 GradePakur VarietyFor works in foundation, basement and upto roof of ground floor/upto4 mtr (Column, Bracing)
2524 m to 8 m (Add extra over the rate of ground floor for basement and each additional floor above ground floor for (
2538 m to 12 m (Add extra over the rate of ground floor for basement and each additional floor above ground floor for (
25412 m to 16m (Add extra over the rate of ground floor for basement and each additional floor above ground floor for (
25516 m to 20 m (Add extra over the rate of ground floor for basement and each additional floor above ground floor for (
25620 m & above (landing, step, roof dome, walk way, platform) (Add extra over the rate of ground floor for basement and each additional floor above ground floor for (
257Controled cement concrete with well graded stone chips (20 mm nominal size) excluding shuttering & reinforcement with complete design of concrete as per [ISI : 456 and relevant special publication. Submission of job mix formula after preliminary mix design after testing of concrete cube as per direction of the EIC. consumption of cement will not be less than 320kg of cement with super plasticiser per cum. of controlled conc. but actual consumption will be determined on the basis of preliminary test & job mix formuta. In ground floor and foundation.[Using concrete mixture] M 30 Grade.In heel beam, conical slab, bottom dome, bottom ring beam, walkway, shell wall etc. Pakur Variety16 m to 20 m (for Heel Beam) (Add extra over the rate of ground floor for basement and each additional floor above ground floor for (
258b) 20 mtr. and above (cell wall, floor, top & bottom ring beam & bottom doom, Walk way and lantern etc).(Add extra over the rate of ground floor for basement and each additional floor above ground floor for (
259Hire and labour charges for shuttering with centreing and necy. staging upto 4m. Using approved stout props and thick hard wood planks of approved thickness with required bracing for conc. slabs, beams, columns, lintels curved or straight includg. fitting, fixing and striking out after completion of works.from foundation to 4m above GLAbove 25 mm and upto 30 mm wooden Shuttering as per direction of EIC.
260Hire & labour chages for shuttering for conc. Work in overhead R.C. Reservoir on separate R.C. frame including fitting, fixing & stricking off after completion of work (From 4m to top of reservoir).
261Extra for staging beyond 4 mtr (Mode of measurement area of unsupported horizontal projection, where staging beyond 4 mtr. is practically un-avoidable) staging height to be considered for 4 mtr. above G.L. to mean height of soffit and plan area in between out side of ring beam minus hollow shaft if any and annular ring beam of staging above metial 4 Mtr.
262Reinforcement in reinforced conc. work in all sorts of structures includg. dist.bars, stirrups, binders etc., initial straightening and removal of loose rust (if necy.) cutting to requisite length, hooking and bending to correct shapde, placing in proper position and binding with 16 gauge balck annealed wire at every intersection, complete as per drawing and direction. (a) For works in foundn. basement and upto roof of ground floor/upto 4m. (i) Tor steel/Mild steel. SAIL/TATA/RINLFor works in foundation, basement and upto roof of ground floor/upto 4 m.
263Extra for works beyond the roof of ground floor/initial 4 m. to 8 mtr.(Add extra over the rate of ground floor/initial 4 m for each basement floor and each additional floor below/ above ground floor
2648 m to 12 m(Add extra over the rate of ground floor/initial 4 m for each basement floor and each additional floor below/ above ground floor
26512 m to 16m(Add extra over the rate of ground floor/initial 4 m for each basement floor and each additional floor below/ above ground floor
26616 m to 20 m(Add extra over the rate of ground floor/initial 4 m for each basement floor and each additional floor below/ above ground floor
267beyond 20 m(Add extra over the rate of ground floor/initial 4 m for each basement floor and each additional floor below/ above ground floor
268Supplying & labour for mixing of super plasticizer of approved make brand sika/cico conforming to IS-2645-1975 & IS-9130-1979 to be need in mortar admixture @ 0.20% by wt. of cement (i.e 100ml per 50kg of cement) for improving workability, reducing shrinkage and improvement of water tightness of the concrete.
269(a) Applying 2 coats of bonding agent with synthetic multi functional rubber emulsion having adhesive and water proofing properties by mixing with water in proportion (1 bonding agent : 4 water : 6 cement) as per Manufacturer"s specification
270(b) Applying 2 coats of Non-Toxic Acrylic Polymer modified Paint having adhesive & waterproofing properties by mixing in proportion (1 liquid: 4 cementitious material) or as per manufacturer"s specification for water proofing layer in water tank etc.
271Supplying mosquito proof net made of polythene (NETLON) size 75cm. X 75cm. for ventilator including fitting, fixing in the best sal wood frame of 8cm. X 5cm. cross section with necessary wooden batten fixing the assembly with necessary MS clamp in RCC wall at the lantern.
272Wood work in door and window frame fitted and fixed in position complete including a protective coat of painting at the contact surface of the frame exluding cost of concrete, Iron Butt Hinges and M.S clamps. (The quantum should be correted upto three decimals).Wood work in door and window frame fitted and fixed in position complete including a protective coat of painting at the contact surface of the frame exluding cost of concrete, Iron Butt Hinges and M.S clamps. The quantum should be correted upto three decimals. d) Sal local
273Artificial stone in floor, dado, staircase etc. with cement concrete (4:2:1) with stone chipes laid in panels as directed toping made with ordinary or white cement (as necy.) & marble dust in proportion (2:1) including smooth finishing & rounding off corners including rackng out joints or roughening of conc. surface & including application of cement shlurry before flooring works, using cement @ 1.75 kg/sqm all complete including all materials & labour above heel beam. 3 mm thick toping high polishing grinding on this item is not permitted with ordinary cement. (a) 25 mm thick. (Reservoir inside floor & wall, walk way floor, cc step, platform landing).
274Supplying at site filling ,fixing ,erecting and building in position where necessary 600mm.wide M.S. Cat ladder as per design consisting of 2nos. ISMC 150, 8mm.thick with necessary base plate of 8mm.thick 100mm.wide M.S. plate as steep @ 300mm.a/c supported on ISA 50x50x6 ,ISA 60x60x8mm.thick both side as per requirement.900mm.ht. as post on one side/both side @ 1000 and ISA 45x45x6 as horiz. Runner to cover side railing including fabrication, welding,drilling etc.as per drawing and direction and finished with two coats of synthetic enamel painting over a coat of primer etc. all complete as per direction of EIC. for cat ladder, railing of stair & platform, walkway etc. e)from 20mtr. to 24mtr. @ 1.5%extra of (d)
275Supplying at site hoisting, fitting, fixing erecting and building in position where necessary 450mm.wide ladder as per design consisting of 2nos. M.S.Plate of 8mm.thick with necessary base plate 60mm wide; and 16mm.dia M.S.round or square bar as steeps placed @ 300 c/c including fabrication, welding drilling etc. as per drawing and direction and finished with two coats of synthetic enamel painting over a coat of red lead primer etc. all complete as per direction of the EIC
276Supplying, fitting, fixing 900 mm high G.I. pipe railing for R.C.C stair cat ladder walk way fabrication,erection,welding of 40 mm G.I (NON TATA medium) pipe place at top of railing and 2 nos 25 mm dia. G.I pipe (NON TATA medium) placed equally in between railing top & floor vertical post of railling are 40 mm dia. G.I pipe (NON TATA medium) placed at 900 mm c/c . The each end of the vertical post is join by the 62 mm (25 mm X 6 mm X 0.062 m long) MS flat and 150 mm length (propes pipes) are grouted in concrete base of stair, walk way etc. All Complete with supplying of all materials including hoisting up to the any height complete with 2 coats of painting with super gloss (Hi gloss) in any shade except white and black over a coat of primer complete as per direction of E.I.C.
277Supplying fitting and fixing in position reinforced cement polymer concrete manhole cover with matching frame as per IS-12592 (MD) a) Square. i) 600 mm x 600 mm x 50 kg (approx)a) 5MT load bearing capacity round manhole cover parovided with two nos. lifter hook with machining frame of size 550mm x 65mm(cover) and 650mm x 125mm(frame) opening 470mm and WT. 90KG. approx.
278Horn gap lighting arrestor complete parts and pin insulators supplying, fitting fixing all complete as per direction of E.I.C.
279Plaster (to wall,floor,ceiling etc.) with sand and cement mortar including rounding off or chamfering corners as directed and raking out joints including throating,nosing and drip course, scaffolding/ staging where necessary. (Excluding cost of chipping over concrete surface) With 1:4 cement mortar 15mm thick plaster. From 16m to 20m of reservoir
280With 1:4 cement mortar 15mm thick plaster. From 20m and above of reservoir
281With 1:3 cement mortar 10mm thick plaster above 20 m & above
282Applying Exterior grade Acrylic primer of approved quality and brand on plastered or concrete surface old or new surface to receive decorative textured(matt finish)or smooth finish acrylic exterior emulsion paint including scraping and preparing the surface throughly,complete as per manufacturer"s specification and as per direction of the EIC.a)One Coat GL to 4 m
2834m to 8 m
2848 m to 12 m
28512 m to 16m
28616 m to 20 m
287above 20 m
288Protective and Decorative Acrylic exterior emulsion paint of approved quality as per manufacturers specification and as per direction of EIC to be applied over acrylic primer as required. The rate includes cost of material , labour, scaffolding, and all other incidental charges but excluding the cost of primer. Two coat. Super protective 100% Acrylic Emalsion.GL to 4 m
2894m to 8 m
2908 m to 12 m
29112 m to 16m
29216 m to 20 m
293above 20 m
294Construction of different dia Sluice valve /Air valve /Washout chamber in different sizes for village road where light traffic run and for main road where heavy traffic run as deptt.approved drawing with 25cm thick brick work (1:6) over cement concrete (4:2:1) over a single B/F soling over150mm.thick sand filling in foundation including earth work in excavation and disposal of excess earth from work site with RCC (1:1.5:3) cover slab 100mm / 150mm thick slab on top of chamber with 1% reinforcement in RCC cover slab with necessary opening for operation of valve all complete including cost of labour & materials as per Departmental Dwg. [Reinforcement type:- Other manufactuerers not specified] 150 mm dia
295100 mm dia.
296Supply & delivery atfollowing nominal sizes and classes CIDF sluice valve in terms with IS 14846-2000, inside screw non rising, stern, flanges faced and drilled as per IS 1538-1993, spindle/ stern with SSAISI410 as per IS 6603-1972, body, bonnet, wedge, stuffing box gland thrust plate, cap inconformity with IS 210-1978, with an amendments order IS specification as stated.(Upadhaya/Kirlosker / kejriwal /IVP/L & T/VAG/M & P) Make class-PN 1.0 with Cap.150 MM dia
297100 mm dia.
298Hoisting, erection ,placing connecting with pipes and specials CIDF pipes, specials) securing with building specials providing stays, clamps as required including cost of staging platform for the work etc.all complete in all respects as per drawing and direction of EIC.100 mm dia.
299150 mm dia.
300Laying of CIDF /D.I Pipes with specials,valves etc. in trenches including excavation in all sorts of soil, moorum, soft rock and refilling the trenches after laying & jointing of pipes etc. all complete as per specification and direction of EIC.100 mm dia.
301150 MM dia
302Fitting, fixing duck foot bend including construction of cement concrete (4:2:1) base with stone chips of approved grade & quality & including excavation of earth etc. complete in all respect 100mm.dia
303150mm.dia
304Hoisting, fitting, fixing of bell mouth with puddle collar in RCC work complete in all respect as per drawing, specification and direction of EIC. 100 mm dia.
305150mm.dia
306Making flange joint to CIDF pipe, specials, valves etc.with supply of necessary nuts and bolts, rubber insertion of 6kg/m2 (3mm gauge) and materials required including dewatering if any tools and plants, labour cost etc. as per specification and direction of EIC (Nut and bolts shall be of TATA/GKW make) for100 mm dia.
307150mm.dia
308Making arrangement for water tightness test conforming to the provision laid in IS:3370(Pt-I) 1956 by filling with water upto top water level (TWL) as shown in the drawing and as per direction of EIC. (if water is supplied by the Department rate shall be reduced as per prevailing departmental rate)
309Disinfection & washing the tank and pipe connections including cleaning the inside of the tank etc complete.
310Neat cement punning about 1.5 mm thick in wall, dado, window, sills, floor, drain etc.Note-cement 0.152 cu.m. per 100 sq.m.
311Number plaque of building (plaque size up to 225 mm x 225 mm) made of sand cement plaster (1 : 2) on face of wall or plinth with 50 mm size letters P.W.D and the number of the structure formed thereon (in sunk type) including painting the letters and the number complete as per direction.
312Supplying and laying standard four course bituminous water proofing treatment as per specification laid down in I.S. 1346 - 1991 to be finished with pea size gravel including necessary preparatory works such as shaping mouth of outlets, cutting as and where necessary and refilling with sand and Cement mortar (4:1) or Cement Concrete (1:2:4) with graded stone chips before undertaking the treatment including cutting grooves in parapet and inserting edge of felt and mending good damage complete in all respect as per direction of Engineer - in - Charge including cost of all materials and labours and incidental charges but excluding the cost of Cement Mortar or concrete required for levelling and grading. (In sloped roof Course sand of approved varieties is to be used in place of Pea size gravels as fourth and final course.) i) 1st and 3rd Course with bonding materials of hot applied industrial blown type bitumen of grade 85/25 or 90/15 conforming to I.S.702 - 1988 @ 12Kg/10Sqm on each layer. ii) 2nd course with Hessian base self finished bitumen type3r.-I conforming to I.S. 1322-1993 (weighing 23kg/10Sqm gross with bitumen content 12.10kg/10Sqm ) tested under the provision of I.S. 13826 - 1993 part VII. iii) 4th course with washed and clean pea sized gravel or grit @ 0.006 cum/SqmB. Over Sloped Roof.
313Supply the following materials for connection of inlet, outlet, overflow and delivery line of ORH asper departmental drawing. A) C.I.D.F. pipe as per I.S.7181 - 1986 with letest revision.
314Bituminous filer of approved type in excavation joint between the shell wall & roof including finishing the top surface as per ;drawing, specification and direction of EIC
315Supplying hoisting, fitting fixing approved type water level indicator with copper float, guide pulley, wire boards etc. as per standard specification and direction and satisfaction of EIC
316Commissioning the R.C.C. over head reservoir by operating of all category of sluice valves , testing of hoisted pipe joints including repairing the leakage(s) if detected , including making inter connections,flange jointing/lead jointing with the newly laid rising main and distribution main all complete as per direction of the EIC.
317Suppling, fitting and fixing M.S clamps door and window frame made of flatbent bar, end bifurcated with necessary screws etc. by cement concrete ((1:2:4) as perdirection of concrete will be paid separatelt.(c) 40mm X 6 mm, 125 mm Length
318(a) M.S or W.I. Ornamental grill approved design joints continuously welded with M.S W.I Flats and bars of windows railing etc. fitted and fixed with bbnecessary screws and luge in ground floor. (Add extra @1% for each addl. Upto 4th floor and @1.25% for each addl. floor above 4th floor) Grill weighing above 10 Kg./sq.m and upto 16 Kg./sq. m.
319Grill weighing above 16 Kg./sq.mtr and above
320Welding in M.S structurral work gas or electric continuous Weld
321Priming one coat on timber or plaster surface with synthetic oil bound primer of approved quality includingsmoothening surfaces by sand papering etc.
322Priming one coat on steelor metalsurface with synthetic oil bound primer of approved quality includingsmoothening surfaces by sand papering etc.(This item is applicable to new work or old work when the original surface has been exposed by removal of old paint)
323Painting with best quality synthetic enamel paint of approved make and brand including smoothening surface by sand papering etc. inclding using of approved putty etc,. on the surface, if necessary :On timber or plastered surfaceWith super gloss (hi-gloss) Two coat (with any shade except white)
324On steel or other metal surface: With super gloss (hi-gloss)Two coat (any shade except white)
325A)Earthing with 50mm.dia G.I. pipe3.64mm.thick x 3mtr. (10”-0”) long and l;1 x 4SWG G.I. (Hot dip)wire 4mtr. long 13mm. dia x 80mm.long G.I.Bolts, double nuts , washer including S&F 15mm.dia G.I.pipe protection (1mtr. long) to be filled with bitumen partly below ground level to an av. Depth of 3.65m below G.L. and restoring the surface duly rammed as per IEE rulei)For soft soil. b)By TATA Medium G.I.Pipe.
326Supplying HDPE (Materials grade PE-100) pipes conforming to IS 49841995 with latest revision & amendments if any with necessary specials (excluding cost of CIDF valves) including labour charges for earth work in excavation in any kind of soil including mixed soil with boulder,road sub-grade and aits flank but excluding moorum laterite or sand stone / hard rock cutting with chisel required including cutting road flank/ brick pavement etc. without damaging the exisiting telephone/electrical cable line etc.(in case of damage of any type of cable line by the agency at the time of execution necessary damage charge as applicable by the respective authority will have to be brone by the agency at his own cost)upto the depth (av.) so as to maintain 1.10m.earth cushion from top of the pipe upto G.L. including loading unloading carrying lowering laying fitting fixing carefully pipes, valves and specials with the all types of jointing materials in trenches maintaining proper levels and alignment jointing the pipes and specials by butt welding/ adopting suitable method (But weld jointing with help of hydraulic tack and trimming machines, Hitter etc. for reaching at necessary melting point of HDPE pipe so that joint can be monolithic) so as to facilitate the maintenance of pipe line locally as per conventional method in future. (A) Pressure Rating : PN 6 (i) Laying of pipe line including cost of pipe only excluding cost of specials/fittings valves. b) 90mm (OD)
327b) 110 mm (OD)
328c) 125mm (Od)
329c) 140 mm (Od)
330c) 160 mm (Od)
331Filling the pipe line with water, testing hydraulically as per I.S 3114-1965 (Article-6) in section of a length not exceeding 500mtr. for head of pressure as per specification including supplying installing and fixing all equipments such as diesel pump set, blank flange, pressure gauge, valve, pressure pump and all other tools and plants including drilling topping and plugging of necessary holes to pipes, blocking ends providing temporary thrust block and subsequent blocking of holes and other jointing materials and dismantling and removal of the same including disposal of water etc. all complete as per specification and direction of EIC. The rate is inclusive of cost of requisite water to be arranged by the contractor (Recovery rate of water @ Rs.10.00/m3, if contractor used water from deptt. source). B) For UPVC/HDPE Pipe a)90 mm (OD)
332b) 110 mm (OD)
333c) 125mm (Od)
334c) 140 mm (Od)
335c) 160 mm (Od)
336A) For CI/DI Pipe b)150 mm dia
337c)200 mm dia
338e) 100 mm dia.
339Cleaning thoroughly the inner surface of pipe line including specials and valves by flushing with water and subsequently disinfection of the same pipe line by flushing again with water containing bleaching powder resulting in residual chlorine not less than 15mg/ltrs. after 24hrs. of such filling including laboratory testing of water samples obtain from the disinfested pipe line and disposal of water from the pipe line after completion of the work. The rates including of cost of requisite water to be arranged by the contractor) (The rate of water @Rs. 10/m3 may be recovered, if the contractor used water from deptt. source). B) For UPVC/HDPE Pipe a)90 mm (OD)
340b) 110 mm (OD)
341c) 125mm (Od)
342c) 140 mm (Od)
343c) 160 mm (Od)
344A) For CI/DI Pipe b)150 mm dia
345c)200 mm dia
346e) 100 mm dia.
347Carrying CI/DI pipes with specials and valves and lowering placing in position and laying carefully inside the trenches in proper alignment and gradient etc. including earth work in excavation of adequate width as per specification having min. clear cover from top of pipe is 1.10mtr. below existing ground level in any kind of soil including mixed with boulder, road sub-grade and its flank,but excluding moorum and laterite and stone etc.without damaging the exisiting telephone/electric cable etc.(in case of damaged if any type of cable line during excecution , necessary damaged charges as applicable by the respective authority will be borne by the agency in his own cost) preparing the bottom surface for continuous bedding of pipe line and laying pipes, fitting, fixing specials and valves with bailing out water if any including carriage of pipes, specials and valves from local deptt. store within 8KM and back filling the trenches with excavated earth in layers to original condition as per specification and direction of EIC. The surplus materials after execution of work are to be return to the deptt. store. N.B: i) Any deviation from required clear cover of 1.10mtr., due to site adverse condition, prior permission is to be obtained from the EIC in exceptional situation and payment will be made on prorate basis over the rate of entire item ii) No payment will be made without hydraulic test of the pipe line either part or full iii) The pipes, specials and valves , rubber gasket will be supplied deptt. free of cost. b) 150 mm dia.
348c) 200 mm dia.
349e) 100 mm dia.
350Making rubber gasket joint to CI/DI pipes maintaining proper alignment level etc. by mechanical arrangement with or without using mobile cranes where necessary and with help of all other equipments tools and tackles etc. as required providing lubricants of approved quality and direction of EIC. (rubber gasket will be supplied deptt. free of cost) b) 150 mm dia.
351c) 200 mm dia.
352e) 100 mm dia.
353Construction of different dia Sluice valve /Air valve /Washout chamber in different sizes for village road where light traffic run and for main road where heavy traffic run as deptt.approved drawing with 25cm thick brick work (1:6) over cement concrete (4:2:1) over a single B/F soling over150mm.thick sand filling in foundation including earth work in excavation and disposal of excess earth from work site with RCC (1:1.5:3) cover slab 100mm / 150mm thick slab on top of chamber with 1% reinforcement in RCC cover slab with necessary opening for operation of valve all complete including cost of labour & materials as per Departmental Dwg. [Reinforcement type:- Other manufactuerers not specified] i) 80 mm to 150 mm dia pipe
354i) 200 mm dia pipe
355Bituminous pucca road (approx. 450mm depth) cutting by using gaiti, chisel, hammer etc. and picking uip the withdrawing excavated materials and remove the same within distance of 30mtr. at least all complete for fixing/crossing all dia of pipe line as per direction of EIC.
356Making barricading of excavation trenches of road width upto 15mtr. to avoid any accident by providing 75mm dia bamboo post placed vertically & horizontally with the help of 6”size iron rail as per direction and satisfaction of EIC. (Applicable where critical situation arise and take up the work as per direction of EIC)
357Labour for horizontal boring under pucca road etc…………....for laying of pipe. i) up to 150 mm dia. (CI/DI/AC/GI)/180 mm O.D UPVC & HDPE
358Making village roadcrossing (Average 3 m width)by horizontal Augor boring for accmodation of laying of average 3 (Three) Nos 15 mm dia GI pipe for FHTC or as per direction of EIC.
359Ordinary Cement concrete (mix 1:2:4) with graded stone chips (20 mm nominal size) excluding shuttering and reinforcement,if any, in ground floor as per relevant IS codes. (b) River bazree
360Bamboo pile walling made of 65 mm to 75 mm dia. Bamboo (in single line) driven about half length into the ground at very close spacing side by side including necessary bamboo stays ties runners etc and lining the exposed portion with sheets made form cutdrums fitted and fixed complete as per direction.
361Supply and delivery of CIDF sluice valve (Special type) PW-1.00 of different dia make with CI double flanged non rusting spindle sluice valves conforming to IS 14846 -2000 with latest emended having body dome/bonnet and cover of C.I.Gr-F.G 210mtr. spindle of IS-6603 G.R- 12/Gr-13 non-magnetic, nuts seat rings are of Gunonetal as per IS:318 LTB-2 flanges and drilled to IS:1538 Part IV & VI valves are suitable for max. working pressure of 10kg/cm2(seat test) and body tested to 15kg/cm2. N.B: The above item should be procured from the reputed manufactures as per deptt. approved vender list 150 mm dia
362200 mm dia
363ADD: GST 18% (+)
364ADD: CESS 1% (+)
Disclaimer :
We takes all possible care for accurate & authentic tender information, however Users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender.
Tell us about your Product / Services,
We will Find Tenders for you

Copyright © 2024 · All Rights Reserved. Terms of Usage | Privacy Policy

For Tender Information Services Visit : TenderDetail