Tender For Providing Mps For Sewerage And Storm Water System In Village Rai And Pumping Station For Liwan Village Falling Under Extended Municipal Limits Of Sonepat Town., sonepat-Haryana

Urban Local Bodies has published Tender For Providing Mps For Sewerage And Storm Water System In Village Rai And Pumping Station For Liwan Village Falling Under Extended Municipal Limits Of Sonepat Town.. Submission Date for this Tender is 08-08-2023. Drainage Tenders in sonepat Haryana. Bidders can get complete Tender details and download the document.




Tender Notice

38723701
Tender For Providing Mps For Sewerage And Storm Water System In Village Rai And Pumping Station For Liwan Village Falling Under Extended Municipal Limits Of Sonepat Town.
Open Tender
Indian
Haryana
sonepat
08-08-2023

Tender Details

Tender For Providing Mps For Sewerage And Storm Water System In Village Rai And Pumping Station For Liwan Village Falling Under Extended Municipal Limits Of Sonepat Town.

Key Value

Document Fees
INR 15000 /-
EMD
INR 2780000.0 /-
Tender Value
INR 13.76 Crore /-

BOQ Items

Name of Work:Providing MPS for sewerage and storm water system in village Rai and Pumping station for Liwan village falling under extended Municipal limits of Sonepat Town.
Sl. No. Item Description
1Construction of cast-in-situ RCC M-30 grade circular manhole chamber of 1200 mm internal diameterincluding required excavation of earth in all types of soils such as murrum, sand, sandy silt, black cottonsoil, hard soil, kankar etc, disposingof surplusexcavated material within a lead of 1.00 Km. The work includes : - • Layingofplaincementconcrete1:3:6(1cement:3coarsesand:6gradedstone aggregate 20 mm nominal size) bedding in foundation. • Laying of RCC base slab with M-30 Concrete • Providing and laying of plain cement concrete 1:2:4 (1 cement: 2 coarse sand : 4 graded stone aggregate ) in channeland benching. • Circular starter M-30 base wall up to 50 mm above outer dia. of sewer pipe and vertical wallin conjective standard size300 mm high rings. • RCC top slab with M-30 concrete and Providing and Fixing (P and F) of560mm SFRC ExtraHeavyDuty(EHD-35)manholecoverandframeasperIS:12592andasper specifications to with stand for class AA loading. • Steel bar embedded plastic steps of size 263 mm X165 mm of orange colour confirming to IS specifications and sealing of alljoints withcement mortar 1:1. Complete job as per detailed specifications, drawings and directions of Engineer-In charge, for following average Invert depths:
2Construction of brick masonary sluice valve, air valve chambers for the valves to be installed in the system. The chamber shall be as per the drawingand material of construction shall be as size 1500x1200mm
3Providing, lowering, stringing, laying,fixing in position and jointing CI/DI dismantling jointas perIS1538ammendeduptodate complete inallrespectofthefollowingsizesincludingall jointing material, cost of all labour, testing and commissioning as per Technical Specifications and as per direction of Engineer 250mm dia
4Providing, lowering, stringing, laying,fixing in position and jointing CI/DI dismantling jointas perIS1538ammendeduptodate complete inallrespectofthefollowingsizesincludingall jointing material, cost of all labour, testing and commissioning as per Technical Specifications and as per direction of Engineer 600mm dia
5Construction ofPumping Stations as per scope, specifications and drawings consisting of: i). RCC Receiving Chamber ii). Sluice Gates iii). Screening Chamber with RCC stair case. iv). Mechanical Screens v). Wet Well with compartment. vi). Pumping Sets with Delivery pipe vii). Lifting Arrangement (includes column,Girder, Chain pully Blck etc.) viii). Pipe Gallery for housing common header pipe, sluice valces, NRV and dismantling joing including specials. ix). Transformer with foundation. x). Diesel Generating Set withplatform and shed. xi). Panel Room with officeand toilet facilities. xii). Electric Control Panel Board xiii). Electric cabling including connecting to Existing Sub-stations, if any. xiv). Metering room xv) Street Lighting. xvi) Internal Roads with drainage. xvii) External sewerage. xviii) Furniture xix) Storage Room xx) Boundary Wall etc. xxi) Any other item required for completion and Satisfactory working of Pumping Stations. Main Pumping Station atvillage Rai (Civil WorkplusScreens = 12 MLDPeak Flow
6Construction ofPumping Stations as per scope, specifications and drawings consisting of: i). RCC Receiving Chamber ii). Sluice Gates iii). Screening Chamber with RCC stair case. iv). Mechanical Screens v). Wet Well with compartment. vi). Pumping Sets with Delivery pipe vii). Lifting Arrangement (includes column,Girder, Chain pully Blck etc.) viii). Pipe Gallery for housing common header pipe, sluice valces, NRV and dismantling joing including specials. ix). Transformer with foundation. x). Diesel Generating Set withplatform and shed. xi). Panel Room with officeand toilet facilities. xii). Electric Control Panel Board xiii). Electric cabling including connecting to Existing Sub-stations, if any. xiv). Metering room xv) Street Lighting. xvi) Internal Roads with drainage. xvii) External sewerage. xviii) Furniture xix) Storage Room xx) Boundary Wall etc. xxi) Any other item required for completion and Satisfactory working of Pumping Stations. Main Pumping Station atvillage Liwan 3 MLD Peak Flow
7Operationandmaintenancecostfor 3 no. STPs, 3 no. MPS and all other works created under the contract for 5 years after defect liability period of 12 months which includes basic service charges having expenditure and expenses required to be incurredonlabour,repairand/orreplacementofmaterials,equipments,consumable items,waterandallothermattersanditemsofwhatsoevernature,essentialand desirabletorunthesystemsatisfactory,AdministrationandManagement,Runningof Office,ComprehensiveOperation,MaintenanceandRepairsincludingPreventive Maintenance, Consumables as per Scope of Work and terms and conditions of contractetc.complete.(This is excluding electric power cost of which shall be borne by the department and high speed diesel which shall be reimbursed to agency by the department as per actual consumption against proof). for the 4th year of OandM
8Operationandmaintenancecostfor 3 no. STPs, 3 no. MPS and all other works created under the contract for 5 years after defect liability period of 12 months which includes basic service charges having expenditure and expenses required to be incurredonlabour,repairand/orreplacementofmaterials,equipments,consumable items,waterandallothermattersanditemsofwhatsoevernature,essentialand desirabletorunthesystemsatisfactory,AdministrationandManagement,Runningof Office,ComprehensiveOperation,MaintenanceandRepairsincludingPreventive Maintenance, Consumables as per Scope of Work and terms and conditions of contractetc.complete.(This is excluding electric power cost of which shall be borne by the department and high speed diesel which shall be reimbursed to agency by the department as per actual consumption against proof). for the 5th year OandM
9Construction of cast-in-situ RCC M-30 grade circular manhole chamber of 1200 mm internal diameterincluding required excavation of earth in all types of soils such as murrum, sand, sandy silt, black cottonsoil, hard soil, kankar etc, disposingof surplusexcavated material within a lead of 1.00 Km. The work includes : - • Layingofplaincementconcrete1:3:6(1cement:3coarsesand:6gradedstone aggregate 20 mm nominal size) bedding in foundation. • Laying of RCC base slab with M-30 Concrete • Providing and laying of plain cement concrete 1:2:4 (1 cement: 2 coarse sand : 4 graded stone aggregate ) in channeland benching. • Circular starter M-30 base wall up to 50 mm above outer dia. of sewer pipe and vertical wallin conjective standard size300 mm high rings. • RCC top slab with M-30 concrete and Providing and Fixing (P and F) of560mm SFRC ExtraHeavyDuty(EHD-35)manholecoverandframeasperIS:12592andasper specifications to with stand for class AA loading. • Steel bar embedded plastic steps of size 263 mm X165 mm of orange colour confirming to IS specifications and sealing of alljoints withcement mortar 1:1. Complete job as per detailed specifications, drawings and directions of Engineer-In charge, for following average Invert depths: For pipe size350-600 mm dia depth from 2.10m to 2.39m
10Construction of cast-in-situ RCC M-30 grade circular manhole chamber of 1200 mm internal diameterincluding required excavation of earth in all types of soils such as murrum, sand, sandy silt, black cottonsoil, hard soil, kankar etc, disposingof surplusexcavated material within a lead of 1.00 Km. The work includes : - • Layingofplaincementconcrete1:3:6(1cement:3coarsesand:6gradedstone aggregate 20 mm nominal size) bedding in foundation. • Laying of RCC base slab with M-30 Concrete • Providing and laying of plain cement concrete 1:2:4 (1 cement: 2 coarse sand : 4 graded stone aggregate ) in channeland benching. • Circular starter M-30 base wall up to 50 mm above outer dia. of sewer pipe and vertical wallin conjective standard size300 mm high rings. • RCC top slab with M-30 concrete and Providing and Fixing (P and F) of560mm SFRC ExtraHeavyDuty(EHD-35)manholecoverandframeasperIS:12592andasper specifications to with stand for class AA loading. • Steel bar embedded plastic steps of size 263 mm X165 mm of orange colour confirming to IS specifications and sealing of alljoints withcement mortar 1:1. Complete job as per detailed specifications, drawings and directions of Engineer-In charge, for following average Invert depths: For pipe size350-600 mm dia Depth from 2.40 m to 2.69 m
11Construction of cast-in-situ RCC M-30 grade circular manhole chamber of 1200 mm internal diameterincluding required excavation of earth in all types of soils such as murrum, sand, sandy silt, black cottonsoil, hard soil, kankar etc, disposingof surplusexcavated material within a lead of 1.00 Km. The work includes : - • Layingofplaincementconcrete1:3:6(1cement:3coarsesand:6gradedstone aggregate 20 mm nominal size) bedding in foundation. • Laying of RCC base slab with M-30 Concrete • Providing and laying of plain cement concrete 1:2:4 (1 cement: 2 coarse sand : 4 graded stone aggregate ) in channeland benching. • Circular starter M-30 base wall up to 50 mm above outer dia. of sewer pipe and vertical wallin conjective standard size300 mm high rings. • RCC top slab with M-30 concrete and Providing and Fixing (P and F) of560mm SFRC ExtraHeavyDuty(EHD-35)manholecoverandframeasperIS:12592andasper specifications to with stand for class AA loading. • Steel bar embedded plastic steps of size 263 mm X165 mm of orange colour confirming to IS specifications and sealing of alljoints withcement mortar 1:1. Complete job as per detailed specifications, drawings and directions of Engineer-In charge, for following average Invert depths: For pipe size350-600 mm dia depth from 2.70. to 2.99m
12Construction of cast-in-situ RCC M-30 grade circular manhole chamber of 1500 mm internal diameterincluding required excavation of earth in all types of soils such as murrum, sand, sandy silt, black cottonsoil, hard soil, kankar etc, disposingof surplusexcavated material within a lead of 1.00 km. The work includes : - •Layingofplaincementconcrete1:3:6(1cement:3coarsesand:6gradedstone aggregate 20 mm nominal size) bedding in foundation. • Laying of RCC base slab with M-30 Concrete • Providing and laying of plain cement concrete 1:2:4 (1 cement: 2 coarse sand : 4 graded stone aggregate ) in channeland benching. • Circular starter M-30 base wall up to 50 mm above outer dia. of sewer pipe and vertical wallin conjective standard size300 mm high rings. • RCC top slab with M-30 concrete andP and F of560 mm SFRC Extra Heavy Duty (EHD 35) manhole cover andframe as per IS:12592 andasper specifications towith-stand for class AA loading. • Providing and Fixing (P and F) steel bar embedded plastic steps of size 263 mm X165 mm of orange colour confirming to IS specifications and sealing of alljoints withcement mortar 1:1. Complete job as per detailed specifications, drawings and directions of Engineer-In charge, for following average Invert depths: For pipe size 350-600 mm dia Depth from 3.00 m to 3.29 m
13Construction of cast-in-situ RCC M-30 grade circular manhole chamber of 1500 mm internal diameterincluding required excavation of earth in all types of soils such as murrum, sand, sandy silt, black cottonsoil, hard soil, kankar etc, disposingof surplusexcavated material within a lead of 1.00 km. The work includes : - •Layingofplaincementconcrete1:3:6(1cement:3coarsesand:6gradedstone aggregate 20 mm nominal size) bedding in foundation. • Laying of RCC base slab with M-30 Concrete • Providing and laying of plain cement concrete 1:2:4 (1 cement: 2 coarse sand : 4 graded stone aggregate ) in channeland benching. • Circular starter M-30 base wall up to 50 mm above outer dia. of sewer pipe and vertical wallin conjective standard size300 mm high rings. • RCC top slab with M-30 concrete andP and F of560 mm SFRC Extra Heavy Duty (EHD 35) manhole cover andframe as per IS:12592 andasper specifications towith-stand for class AA loading. • Providing and Fixing (P and F) steel bar embedded plastic steps of size 263 mm X165 mm of orange colour confirming to IS specifications and sealing of alljoints withcement mortar 1:1. Complete job as per detailed specifications, drawings and directions of Engineer-In charge, for following average Invert depths: For pipe size 350-600 mm dia Depth from 3.30 m to 3.59 m
14Construction of cast-in-situ RCC M-30 grade circular manhole chamber of 1500 mm internal diameterincluding required excavation of earth in all types of soils such as murrum, sand, sandy silt, black cottonsoil, hard soil, kankar etc, disposingof surplusexcavated material within a lead of 1.00 km. The work includes : - •Layingofplaincementconcrete1:3:6(1cement:3coarsesand:6gradedstone aggregate 20 mm nominal size) bedding in foundation. • Laying of RCC base slab with M-30 Concrete • Providing and laying of plain cement concrete 1:2:4 (1 cement: 2 coarse sand : 4 graded stone aggregate ) in channeland benching. • Circular starter M-30 base wall up to 50 mm above outer dia. of sewer pipe and vertical wallin conjective standard size300 mm high rings. • RCC top slab with M-30 concrete andP and F of560 mm SFRC Extra Heavy Duty (EHD 35) manhole cover andframe as per IS:12592 andasper specifications towith-stand for class AA loading. • Providing and Fixing (P and F) steel bar embedded plastic steps of size 263 mm X165 mm of orange colour confirming to IS specifications and sealing of alljoints withcement mortar 1:1. Complete job as per detailed specifications, drawings and directions of Engineer-In charge, for following average Invert depths: For pipe size 350-600 mm dia Depth from 3.60 m to 3.89 m
15ContructionofNalatappingarrangementfortappingfrompond nearBDOofficeasper drawing and specification
16Operation and maintenance cost for 2 no. MPS and all other works created under the contract for 5 years after defect liability period of 12 months which includes basic service charges having expenditure and expenses required to be incurred on labour, repair and / or replacement of materials, equipments, consumable items, water and all other matters and items of what so ever nature, essential and desirable to run the system satisfactory, Administration and Management, Running of Office, Comprehensive Operation, Maintenance and Repairs including Preventive Maintenance, Consumables as per Scope of Work and terms and conditions of contract etc. complete.(This is excluding electric power cost of which shall be borne by the department and high speed diesel which shall be reimbursed to agency by the department as per actual consumption against proof). for the 3rd year of OandM
17Operation and maintenance cost for 2 no. MPS and all other works created under the contract for 5 years after defect liability period of 12 months which includes basic service charges having expenditure and expenses required to be incurred on labour, repair and / or replacement of materials, equipments, consumable items, water and all other matters and items of what so ever nature, essential and desirable to run the system satisfactory, Administration and Management, Running of Office, Comprehensive Operation, Maintenance and Repairs including Preventive Maintenance, Consumables as per Scope of Work and terms and conditions of contract etc. complete.(This is excluding electric power cost of which shall be borne by the department and high speed diesel which shall be reimbursed to agency by the department as per actual consumption against proof). for the 2nd year of OandM
18Operation and maintenance cost for 2 no. MPS and all other works created under the contract for 5 years after defect liability period of 12 months which includes basic service charges having expenditure and expenses required to be incurred on labour, repair and / or replacement of materials, equipments, consumable items, water and all other matters and items of what so ever nature, essential and desirable to run the system satisfactory, Administration and Management, Running of Office, Comprehensive Operation, Maintenance and Repairs including Preventive Maintenance, Consumables as per Scope of Work and terms and conditions of contract etc. complete.(This is excluding electric power cost of which shall be borne by the department and high speed diesel which shall be reimbursed to agency by the department as per actual consumption against proof). for the 1st year of OandM after DLP Liwan and Rai
19Operation and maintenance cost for 2 no. MPS and all other works created under the contract for 5 years after defect liability period of 12 months which includes basic service charges having expenditure and expenses required to be incurred on labour, repair and / or replacement of materials, equipments, consumable items, water and all other matters and items of what so ever nature, essential and desirable to run the system satisfactory, Administration and Management, Running of Office, Comprehensive Operation, Maintenance and Repairs including Preventive Maintenance, Consumables as per Scope of Work and terms and conditions of contract etc. complete.(This is excluding electric power cost of which shall be borne by the department and high speed diesel which shall be reimbursed to agency by the department as per actual consumption against proof). for the DLP For MPS Liwan and Rai
20Providing, lowering, laying, aligning, fixing in position in pipe line, manually operated DI D/F Sluice valves of approved make PN 1.0 class of following dia complete (including jointing and jointing material) including all material, labour, testing and commissioning along with pipe line as per Technical Specifications and as per direction of Engineer.
21Providing, lowering, laying, aligning, fixing in position in pipe line, manually operated DI D/F Sluice valves of approved make PN 1.0 class of following dia complete (including jointing and jointing material) including all material, labour, testing and commissioning along with pipe line as per Technical Specifications and as per direction of Engineer.